1 HUMIDIFIERS MODELS HUM HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBLBP2018-A-- HUMBBWTR2019-A-- HUMBBSBP2017-A-- All Bryant humidifiers are designed for easy installation and quiet operation with heat pumps as well as upflow, downflow, or horizontal furnaces. Humid air is circulated throughout the home by the central heating system. All Bryant humidifiers are equipped with a humidistat to maintain the desired humidity level. Access to the media pad in the humidifier is convenient and tools are not required, allowing easy pad replacement. The fan-powered humidifiers, Model HUMBBLFP and HUMBBSFP, are designed for simple installation on supply ductwork, without a bypass duct required. Humidity is achieved by drawing heated supply air through a wet media pad, by means of the humidifier s fan. The HUMBBLFP offers high evaporation rate, up to 25 gallons of moisture per day. For smaller, tighter constructed, or well insulated homes, the HUMBBSFP can deliver up to 16 gallons of moisture per day. The by-pass humidifiers, Model HUMBBLBP and HUMBBSBP, are designed for installation on the supply or return ductwork, by means of a bypass duct on a forced air heating system. Bypass humidifiers operate on the pressure differential between supply and return ductwork, bypassing heated supply air through the wet media pad, and back into the return air. The HUMBBLBP offers up to 18 gallons of moisture per day with front bypass duct discharge. The HUMBBSBP can deliver up to 17 gallons of moisture per day and has a reversible side bypass duct discharge. The humidifiers mentioned are constructed of high-impact, Lexan thermoplastic to provide years of durability. Mineral buildup is reduced by continual flushing with fresh water. The water valves are low-voltage DC solenoid valves, offering quiet operation. The voltage is then rectified to AC for installation. The Model HUMBBWTR is rated up to 19 gallons of moisture per day and because of its no-drain construction, it is perfect for areas where hard water is not a problem. This Model is a bypass humidifier and is reversible for right or left duct runs. A rotating foam drum is operated by a synchronous motor and a float valve maintains the water level to keep the drum wet. An observation window allows for convenient visual maintenance checks. Form No. PDS HUM.56.1
2 * Per ARI Standard 610, 60 F water, 0.20 in. wc. Single pole, single throw. SPECIFICATIONS MODEL HUMBBSBP2017-A-- HUMBBLBP2018-A-- HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBWTR-2019-A-- ARI CAPACITY* 140 (Lbs/hr) 17 (5.9) 18 (6.3) 25 (8.7) 16 (5.6) 19 (6.6) 120 (Lbs/hr) 12.8 (4.4) 13.5 (4.7) 18.8 (6.5) 12.8 (4.4) 14.3 (5.0) TYPE Airflow Bypass Fan Bypass Waterflow Drain Through No drain GENERAL Evaporator Pad-Replacement 88NH1011C101 88NH1014C NH0901D101 Material of Evap Pad Treated Expanded Aluminum Polyether Foam Size (H x W x D) of Evap Pad 10-7/8 x 10-7/16 x 14 x 10-5/8 x 1-3/4 9-3/4 x 9-1/4 x 1-1/4 9 Dia x 8-7/8 1-3/4 Pad Access Side (Right or Left) with Snap Latch Top and Bottom with Thumbscrew Side (Right or Left) and Front Access Front with 2 Pawl Latches Unit Size (H x W x D) 13-3/4 x 13-3/4 x 7-5/ /8 x 16-5/8 x 5-13/ /8 x 16-5/8 x 8-13/ x 12 x /2 x 11-7/8 x 11-7/8 Weight (Lb) Water Usage (Gal/hr) Float Controlled ELECTRICAL CONTROL Low-Voltage Terminals Volts Amps (MAX) VA (MAX) 12 3 Watts 10 3 High Voltage Cord Volts NA 115V - 1PH - 60HZ NA Amps NA NA CONNECTIONS Water Inlet 1/4-in. Tubing or 3/4-in. Garden Hose 1/4-in. Tubing Water Drain 5/8-in. Tubing 1/2- or 5/8-in. Tubing 5/8-in. tube 1/2-in. Tubing Duct 6-in. Round, Right/Left 6-in. Round, Front NA 6-in. Round, Right/Left Duct Opening (In) (W x H) 11-1/2 x 11-3/4 15-1/2 x 13-1/2 15-1/2 x 13-1/ x /8 x 11-1/2 MATERIALS Cabinet Silver Sage Material High Temperature, Thermoplastic (Lexan) Prepainted Galvanized Steel Valve Nylon Polypropylene Water Pan NA Polypropylene Drum NA Polypropylene STANDARD EQUIPMENT Water Valve Solenoid, 24 VDC Solenoid, 24 VDC Converted to 24VAC Float Rectifier,, 24 VDC NA Motor NA Thermally Protected Thermally Protected, Synchronous 115 VAC,1/.60 Hp 115 VAC, 25MHP Relay NA SPST, SPST, 24VDC to AC NA Humidistat SPST Saddle Valve Standard Damper Standard N/A Standard Template Standard Mounting Hardware Standard 2
3 ACCESS PANEL (TOP & BOTTOM) WATER INLET OPTIONAL WATER VALVE MOUNTING WATER INLET SIDE DOOR VOLT PLUG CORD VAC V PLUG CORD FRONT ACCESS COVER Model HUMBBLFP1025-A-- A98358 Model HUMBBSFP1016-A-- A96482 ACCESS PANEL (TOP & BOTTOM) WATER INLET DIA Model HUMBBLBP2018-A-- A98359 ACCESS PANEL WATER SUPPLY CONN. WATER INLET ACCESS PANEL OVER-FLOW 6 DIA PLUG Model HUMBBWTR2019-A-- A96484 Model HUMBBSBP2017-A-- A
4 OUTDOOR TEMP ( F) RECOMMENDED RELATIVE HUMIDITY BY OUTDOOR TEMPERATURE OUTDOOR RELATIVE HUMIDITY (%) MAXIMUM RECOMMENDED INDOOR RELATIVE INDOOR HUMIDITY (%) RELATIVE W/O HUMIDIFIER* HUMIDITY to 70 1 to 2 20 (Lo) 0 30 to 70 2 to to 70 3 to to 70 4 to to 70 6 to (Med) * Indoor relative humidity level when outdoor air is heated to 72 F. As stipulated by the Air Conditioning Contractors of America. INDOOR RELATIVE HUMIDITY LIMIT FOR NO WINDOW CONDENSATION (Indoor Air at 74 F Dry Bulb) OUTDOOR TEMPERATURE ( F) SINGLE PANE WINDOWS (%) DOUBLE PANE WINDOWS (%) MAXIMUM MOISTURE REQUIREMENTS* VOLUME OF TIGHT HOUSE AVERAGE HOUSE RESIDENCE (CU FT) Pounds Per Hour Gallons Per Day Pounds Per Hour Gallons Per Day 8, , , , , , , , , , , , * Based on design conditions of outdoor 20 F dry bulb, 80% RH; indoor 70 F dry bulb, 40% RH, and minimum moisture production from residential operations for an absolute humidity difference of lbs/hr. NOTE: Tight house is defined as being well insulated, having vapor barriers, tight storm doors and windows with weatherstripping, and having dampered fireplaces. Average house is defined as being insulated, having vapor barriers, loose storm doors and windows, and having dampered fireplaces. 4
5 EVAPORATION RATE VS STATIC & AIR TEMP ( F) GALLONS/DAY HUMBBLFP HUMBBLBP HUMBBSBP HUMBBWTR HUMBBSFP AIR PERCENTAGE OF ARI CAPACITY (140 F, 0.20 IN. WC) ARI RATING POINT AIR 120 AIR 100 AIR 80 AIR BYPASS DIFFERENTIAL STATIC IN. WC + FAN UNIT CAPACITY VARIES ONLY W/AIR TEMP. AT 0.20 STATIC POINT NOTE: DUCT STATIC HAS NO EFFECT ON 913B A98397 ADDITIONAL EVAPORATION RATE USING HOT WATER 24 GALLONS/DAY HUMBBLFP HUMBBLBP HUMBBSBP HUMBBWTR HUMBBSFP N/A* 4.1 PERCENTAGE INCREASE AGAINST ARI EVAPORATION RATE (140 F, 0.20 IN. WC) N/A* N/A* N/A* WATER TEMPERATURE ( F) NOTE: 914A, NO = 0% (USE OF HOT WATER HAS LITTLE OR NO EFFECT DUE TO NON-FLOW THRU DESIGN OF 914A) A
6 TYPICAL HUMIDIFIER INSTALLATIONS UPFLOW UPFLOW A98354 MODEL HUMBBWTR2019-A-- MODEL HUMBBLFP1025-A-- IN AN UPFLOW INSTALLATION IN AN UPFLOW INSTALLATION A96493 HORIZONTAL DOWNFLOW MODEL HUMBBWTR2019-A-- IN A DOWNFLOW INSTALLATION A98353 MODEL HUMBBLBP2018-A-- IN A HORIZONTAL INSTALLATION A
7 7
8 SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG [ ] Packaged Service Training [ ] Classroom Service Training A94328 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS 912D.56.3B Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN PRINTED IN U.S.A. Catalog No. 12HU-MB0 7-98
Product Data. HUM Humidifiers
Product Data HUM Humidifiers Model HUMCCLFP1025-A-- Model HUMCCSFP1016-A-- Model HUMCCLBP2018-A-- Model HUMCCWTR2019-A-- Model HUMCCSBP2017-A-- All Carrier humidifiers are designed for easy installation
More informationProduct Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers
HEATING & COOLING Product Data 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers Model 49FH Model 49WS Model 49BF Model 49FP Model 49BG All Carrier humidifiers are designed for easy installation and quiet operation
More informationMODELS HUM HUMIDIFIERS. Form No. PDS HUM Model HUMBBLFP1318 FEATURES/BENEFITS. Model HUMBBLBP2317. Model HUMBBSBP2312
HUMIDIFIERS MODELS HUM Model HUMBBLFP1318 Model HUMBBLBP2317 Controlling your indoor humidity is very important. In many cases the air inside a home is drier than a desert. Dry, indoor air is often the
More informationProduct Data. HUM Humidifiers FEATURES/BENEFITS
Product Data HUM Humidifiers Model HUMCCLFP1218 Model HUMCCLBP2217 Model HUMCCSBP2212 Controlling your indoor humidity is very important. In many cases the air inside a home is drier than a desert. Dry,
More informationProduct Data. HUM Humidifiers FEATURES/BENEFITS
Humidifiers Product Data Large Fan Powered Model BBLFP1418 Controlling indoor humidity is very important. In many cases the air inside a home is drier than a desert. Dry, indoor air is often the culprit
More informationProduct Data. HUM Humidifiers. FEATURES/BENEFITS (Bypass & Fan Powered Models) FAN POWERED MODELS BYPASS MODELS STEAM MODEL
HUM Humidifiers Product Data HUMXXLFP1518 FAN POWERED MODELS BYPASS MODELS HUMXXSFP1012 HUMBBLBP2417 HUMBBSBP2412 HUMBBWBP2417 (water saver) STEAM MODEL HUMXXSTM3034 Controlling indoor humidity is very
More informationProduct Data. HUM Humidifiers FEATURES/BENEFITS
Product Data HUM Humidifiers HEATNG & COOLNG Model HUMCCLFP218 Model HUMCCLBP2217 Model HUMCCSBP2212 Controlling your indoor humidity is very important. n many cases the air inside a home is drier than
More informationFF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D
FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are
More informationFAN UNIT FH4A Sizes 001 thru 004
FAN UNIT FH4A Sizes 001 thru 004 PRACTICALITY & PERFORMANCE Reliability, dependability, and great value are built into the FH4A Fan Units. The unit is compact and easy to install, with capacities ranging
More informationTOTALINE HUMIDIFIERS HUMIDIFIES TOTALINE GOLD FLOW-THROUGH HUMIDIFIER
TOTALINE HUMIDIFIERS TOTALINE HUMIDIFIERS MAKE YOURSELF COMFORTABLE WITH TOTALINE It s easy. Just choose the Totaline quality humidifier that fits your needs. All Totaline humidifiers are designed for
More informationProduct Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS
Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air
More informationinstallation and start-up instructions HUMIDIFIERS AND HUMIDISTAT
installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT HUM Cancels: II 912D-56-3 II HUM-56-1 7-98 MODEL HUMBBLFP1025-A-- FAN-POWERED HUMIDIFIER MODEL HUMBBLBP2018-A-- BYPASS HUMIDIFIER MODEL
More informationProduct Data MECH. Mechanical Filter Air Cleaner
Product Data MECH Mechanical Filter Air Cleaner Carrier s long and successful history of HVAC innovation continues with the introduction of a new air cleaner product line. Now available to distribution
More informationProduct Data. FH4A Fan Unit. Sizes 001 thru 004
Product Data FH4A Fan Unit Sizes 001 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,
More informationProduct Data. FH4A Fan Unit. Sizes 001 thru 004
Product Data FH4A Fan Unit Sizes 00 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,
More informationProduct Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price
Product Data 58PAV Energy-Efficient Induced-Combustion Upflow Furnace Input Capacities: 45,000 thru 155,000 Btuh 80% AFUE At Budget Price Carrier provides an 80 percent Annual Fuel Utilization Efficiency
More informationFan Powered and Bypass Humidifiers
Fan Powered and Bypass Humidifiers THUMD500APA00B - Fan Powered Humidifier THUMD300ABA00B - Large Bypass Humidifier THUMD200ABM00B - Small Bypass Humidifier THUMD500A THUMD200A/300A 2009 Trane PUB. NO.
More informationMODEL HUM HUMIDIFIERS
HOMEOWNER S MANUAL MODEL HUM HUMIDIFIERS Model HUMBBLFP1025-A-- Fan-Powered Humidifier Model HUMBBSFP1016-A-- Fan-Powered Humidifier Model HUMBBLBP2018-A-- Bypass Humidifier Model HUMBBSBP2017-A-- Bypass
More informationProduct Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation
Product Data 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces 58BLA Low-Boy AN INDEPENDENT LABORATORY TESTING FOR PUBLIC SAFETY ama 58BMA 3-Way Multipoise 58BTA Upflow/Horizontal Copyright 1996 Carrier Corporation
More informationInstallation Instructions Owner s Manual
Installation Instructions Owner s Manual FOR USE WITH GAS, OIL and HYDRONIC FORCED AIR FURNACES SEQUENCE OF OPERATION The AUTOFLO Model s SC15 & 250 use the evaporative principal to add moisture to the
More informationINDOOR AIR QUALITY PRODUCTS
INDOOR AIR QUALITY PRODUCTS www.fasthvacrparts.com FAST Parts International Comfort Products TABLE OF CONTENTS FILTER HOUSINGS FOR GAS FURNACES FHG Series...Page 4 FILTER HOUSINGS FOR AIR HANDLERS FHE
More informationInstallation Instructions
Installation Instructions Cased Horizontal Furnace Coil CK3B A96318 Fig. 1 Model CK3B Furnace Coil NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper
More informationInstallation Instructions
HUMBBSFP1016 HUMCCSFP1016 Small Fan Powered Humidifier and Humidistat Installation Instructions! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.
More informationInstallation Instructions
Installation Instructions For Cased and Uncased Coils Upflow-Downflow Heating-Cooling CK5A, CK5B Cased CJ5A Uncased SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Coil Installation
More informationINSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS For the UH-301 and UH-303 Ultrasonic Humidifiers HUMIDITY SOURCE LLC 30 Garden Ct. S.Garfield, NJ 07026 USA humiditysource@aol.com Phone: 973-916-1001
More informationDuct Mount Rotating Drum Humidifier
Duct Mount Rotating Drum Humidifier Model 465-C1 Manual for: Installation Operation Maintenance Table of Contents Introduction...1 Specifications...1 Capacity Selection Guide...1 Installation Physical
More informationProduct Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh
Product Data 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh *High Efficiency and Flexibility Designed to Meet the Needs of New Homes
More informationG-100ES Duct Mount Humidifier
G-100ES Duct Mount Humidifier Installation Operation Maintenance CAUTION: READ INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS CAREFULLY FOR SAFE OPERATION. EXERCISE EXTREME CAUTION WHEN WORKING
More information395CAV Sizes 045 thru 155 Series H and J
ENERGY-EFFICIENT INDUCED-COMBUSTION DELUXE UPFLOW FURNACE 395CAV Sizes 045 thru 155 Series H and J With a unique approach to induced-combustion design, a 40-in. tall cabinet, 4-pass heat exchanger, an
More informationRECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS
FOR USE WITH ALL FORCED AIR SYSTEMS SEQUENCE OF OPERATION The AUTOFLO Model s 200P, 800BP and 97 Humidifiers use the evaporative by-pass principal to add moisture into the return air duct of your central
More informationProduct Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006
Product Data FK4C Direct Expansion Fan Coil Sizes 00 thru 00 FK4C Premium Air Handling Technology The FK4C is the latest in air handling technology. It is the perfect unit when you need a fan coil that
More informationFAST Indoor Air INDOOR AIR QUALITY. FAST Parts - International Comfort Products -Lewisburg, TN. Lit. No.: Rev
FAST Indoor Air Qualit y Products Manufacturer reserves the right to discontinue or change at any time, specifications or designs without notice or without incurring obligations. Performance of the Air
More informationModel 655A Sizes
Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,
More informationG-100ES Duct Mount Humidifier
Warranty Limited Two Year Warranty This limited warranty covers Herrmidifier Residential Type s, excluding duct work, wiring and installation. Herrmidifier. warrants that all new Herrmidifier s are free
More informationInstallation Instructions
FAVXXR6C2100-A01 Vent Damper and Control Installation Instructions FAMILIARIZE YOURSELF WITH THE INSTALLATION INSTRUCTIONS BEFORE STARTING ATTENTION INSTALLER: This product must be installed by a qualified
More informationBYPASS AND POWER HUMIDIFIER OWNER S MANUAL
ResearchPr 57 Bypass v2 4/15/03 10:22 AM Page 1 READ AND SAVE THESE INSTRUCTIONS BYPASS AND POWER HUMIDIFIER OWNER S MANUAL Includes Safety, Operating, and Maintenance Instructions and Warranty ResearchPr
More informationModel GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES
SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven
More informationProduct Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons
Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional
More informationInstallation Instructions
Installation Instructions Electric Heater Packages KFAEH TE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT GROUND
More informationHUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG
49FH, 49FP, 49BF, 49WS, & 49BG HUMIDIFIERS READ AND SAVE THESE INSTRUCTIONS Model 49FH Fan-Powered A95248 Model 49FP Fan-Powered A95249 Model 49BF Bypass A95250 Model 49WS Water-Saver Bypass A95251 Model
More informationProduct Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING
DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S
More informationHEALTHY CLIMATE HUMIDIFIER
Humidifiers 0,880M /00 HEALTHY CLIMATE HUMIDIFIER OPERATING INSTRUCTIONS FOR MODELS WB-, WB-7, WB-7A, WP-8 & WP-8A Includes Safety, Operating, and Maintenance Instructions Introduction Thank you for your
More informationProduct Data 369AAN FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY
Multipoise Oil Furnace Input Capacities; 70,000 thru 154,000 Btuh eries D Product Data THE LATET IN OIL FURNACE TECHNOLOGY A06623 The model combines high efficiency and quiet operation with oil heating
More informationInstallation, Operation and Service Manual
Installation, Operation and Service Manual Conforto Electric Furnace KHE 10 TO 27kW INSTALLATIONS MUST MEET ALL LOCAL AND FEDERAL CODES THAT MAY DIFFER FROM THIS MANUAL Please read the manual in its entirety
More informationProduct Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:
DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230
More information1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.
SECTION 15855 GAS FURNACE/DX COOLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of contract including General and Supplementary Conditions of Division 1 of Specification
More informationProduct Specifications. Vertical Floor Consoles By First Co.
NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series
More information15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal
Product Data 40FKA Comfort Heat Pump System Fan Coil Sizes 002 thru 006 THERMIDISTAT CONTROL OUTDOOR TEMPERATURE SENSOR 40FKA FAN COIL Comfort Heat Pump System Fan Coil and Thermidistat Control Revolutionizing
More informationInstallation Instructions
Coupling Box Kit Cancels: IIK 340M-40-79 IIK 340M-40-88 9-05 Installation Instructions Part No. 320721-765, 330539-751, -752, -753, -754, -755, -756, and -757 NOTE: Read the entire instruction manual before
More informationMX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat
SG-MAH-08 April 2016 MX Series Indoor Modular Blowers Electric Heat, Hot Heat, or No Heat Specification Guide Contents...Pa Page Standard Features... 2 Physical Data... 2 Blower Performance... 3 Nomenclature...
More informationSubmittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES
180-300 INGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNIT 15-25 NOMINAL TON ubmittal Data DECRIPTION The units are one -piece electric cooling/optional electric heating units, prewired and precharged.
More informationSteam Humidification Light Commercial Applications. Better technology means better business.
Steam Humidification Light Commercial Applications Better technology means better business. Aprilaire Steam Humidifiers are built to last. Through extensive research and over 50 years expertise in humidification
More informationTECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental
TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
016---028 Single---Package Cooling Units with Factory---Installed Optional Electric Heat Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION
More informationInstallation Instructions. SPANISH Installation Instructions. FRENCH Installation Instructions
Installation Instructions for Models 45, 90 and 190 Bypass Drum Humidifiers Inside Front Cover Model / Modelo / Modèle 45 Contractor: Read these instructions before installing or servicing humidifier.
More informationProduct Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:
DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed
More informationProduct Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh
Product Data 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace Series 121 Input Capacities: 4, thru 12, Btuh U L T R A H I G H E F F I C I E N C Y G A S F U R N A N C E Variable capacity,
More informationProduct Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:
PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230
More informationProduct Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh
Product Data 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh Efficiency and Flexibility Designed to Meet the Needs of New
More informationHumidifiers Dealer Parts List Model 400/400M Humidifiers
Effective Date: September 1, 2012 Humidifiers Dealer Parts List Model 400/400M Humidifiers MODEL 400 MODEL 400M NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO. 4B Base (blue/gray) 1 4734 4734
More informationCAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents
IAQ HUMIDIFIERS Litho U.S.A. 2007 Dallas, Texas, USA 505,289M 08/2007 Supersedes 02/2007 KAZ # C.6046 HCWB2 & HCWP2 SERIES USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS Table Of Contents Introduction....................................
More informationMODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3
DIRECT EXPANSION FAN COIL MODEL FK4C Sizes 001 thru 006 FK4C Premium Air Handling Technology The FK4C is the latest in air handling technology. It is the perfect unit when you need a fan coil that can
More informationCAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents
IAQ HUMIDIFIERS Litho U.S.A. 2007 Dallas, Texas, USA 505,289M 09/2008 Supersedes 08/2007 KAZ # C.6046 HCWB2 & HCWP2 SERIES USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS Table Of Contents Introduction....................................
More informationINSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES
INSTALLATION NUAL MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: GENERAL.............................................. 1 SAFETY................................................ 1 UNIT INSTALLATION.....................................
More informationUpflow/Downflow Horizontal Right or Left Gas-Fired Furnace
Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace XT 80 TUDA00A9H2B, TUDB060A9H3B TUDB080A9H3B, TUDC080A9HB TUDB00A9H3B, TUDC00A9H5B TUDDA9H5B, TUDD0A9H5B TDDB060A9H3B, TDDB080A9H3B TDDC00A9H5B,
More informationFEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).
This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency
More information355MAV Sizes 040 thru 120 Series E
DELUXE 4-WAY MULTIPOISE VARIABLE-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE 355MAV Sizes 040 thru 120 Series E HIGH EFFICIENCY GAS FURNACE VARIABLE CAPACITY SYSTEM THE INTELLIGENT ING MACHINE Building
More informationVNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL
VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL 25--21--65 Representative photo only, some models may vary in appearance. MANUFACTURED FOR NATURAL GAS CONVERTIBLE TO (LP) PROPANE GAS NOTE: These
More informationProduct Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology
Product Data 58CMA Multipoise Oil Furnace Series 120 Input Capacities: 70,000 thru 154,000 Btuh The Latest in Oil Furnace Technology The model 58CMA combines high efficiency and quiet operation with the
More informationProduct Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006
Product Data FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant Sizes 002 thru 006 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4A the most advanced air handler available.
More informationHumidifiers Dealer Parts List
Effective Date: July, 204 Revised Date: March 20, 205 Humidifiers Dealer Parts List Model 400/400M Humidifiers 6A 6B MODEL 400 MODEL 400M NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO. 4B Base
More informationProduct Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology
Product Data 58CMA Multipoise Oil Furnace Series 110 Input Capacities: 70,000 thru 154,000 Btuh The Latest in Oil Furnace Technology The model 58CMA combines high efficiency and quiet operation with the
More informationTECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)
TEHNIAL UIDE SINLE PIEE VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLIN & HEAT PUMPS MODELS: AV24 THRU 60*() DESRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationMODELS VA3B, VB5B VC5B
HEAT RECOVERY VENTILATORS MODELS VA3B, VB5B VC5B VA3B VB5B The Heat Recovery Ventilation (HRV) system offered by Bryant is the finest unit on the market today. The VA3B, VB5B, and VC5B provide efficient
More informationTECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)
TECHNICAL GUIDE VARIALE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: N1VS 600-2000 CFM LOWERS 2-5 TON COILS OPTIONAL 1 & 3 φ ELECTRIC HEATERS ISO 9001 Certified Quality Management
More informationHigh Heat COP. High/Low Stage
SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin
More informationXV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO
Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner XV80i TUD2B060AFV32A, TUD2B080AFV32A, TUD2C080AFV42A, TUD2B100AFV32A, TUD2D120AFV52A 2009 Trane All Rights Reserved
More informationProduct Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE
4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURCE Product Data A9801 Utilizing the extensive resources available to Payne, a new standard of excellence has been achieved with the model. The model is a unique
More informationUpflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace
Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA
More informationVertical Upflow Horizontal Left Air Handlers
Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with
More informationWITH TECHNICAL INFORMATION & REFERENCE GUIDE SKUTTLE HIGH-EFFICIENCY HUMIDIFIERS AIR CLEANERS MAKE-UP AIR CONTROLS AIR PURIFICATION
WITH TECHNICAL INFORMATION & REFERENCE GUIDE SKUTTLE HIGH-EFFICIENCY HUMIDIFIERS AIR CLEANERS MAKE-UP AIR CONTROLS AIR PURIFICATION Skuttle Indoor Air Quality Products Thank you for choosing Skuttle! As
More informationUpflow/ Downflow Horizontal Right or Left Gas-Fired Furnace
Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace Freedom 80 AUD2A00A922A, AUD2A060A9362A, AUD2B060A9362A, AUD2B080A9362A, AUD2B080A982A, AUD2B00A9362A, AUD2C00A982A, AUD2C00A9602A, AUD2D00A9602A,
More informationVertical Air Handler Unit
Bulletin 20-019 (September 2016) Vertical Air Handler Unit For cooling, the unit is designed for R-410A refrigerant (both A/C and Heat Pump) or a chilled water coil. For heating, the unit offers an optional
More information50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT
-1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier
More informationFLOW-THROUGH FURNACE HUMIDIFIER
FLOW-THROUGH FURNACE HUMIDIFIER Installation Warranty Maintenance Troubleshooting Guide 2 Installation READ COMPLETE INSTALLATION INSTRUCTIONS AND TEMPLATE BEFORE STARTING Attention Installer: Installation
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION
More informationInstallation Instructions
Installation Instructions Manufactured Housing Blower Package for Electric Furnaces KMABA----TE KMABA----TE NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS
More informationContinue to next pages for Template instructions, Owners Guide, Humidistat Instructions.
This.Pdf document is for informational purposes only and contains an Installation Template. The Template in this.pdf document is not to scale. Do not use for sizing purposes. Continue to next pages for
More informationFOR YOUR SAFETY IMPORTANT WARNING. installation and service manual evaporative cooler model series H & O H76353A
5H76353A May, 2010 installation and service manual evaporative cooler model series H & O c 9900100 us FOR YOUR SAFETY The use and storage of gasoline or other flammable vapors and liquids in open containers
More informationProduct Data. 58MEC PERFORMANCE BOOST WAY MULTIPOISE STAGE CONDENSING GAS FURNACE Input Rates: 60,000 thru 120,000 Btuh
PERFORMANCE BOOST 90 4 --- WAY MULTIPOISE 2 --- STAGE CONDENSING GAS FURCE Input Rates: thru 1,000 Btuh Product Data 4 -WAY MULTIPOISE DESIGN ALLOWS MORE APPLICATIONS design, the secondary heat exchanger
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...
More informationREAD AND SAVE THESE INSTRUCTIONS. Centrifugal Atomizing Humidifier. Trion
READ AND SAVE THESE INSTRUCTIONS 707 Centrifugal Atomizing Humidifier Trion www.trioniaq.com Installation, Operation, & Maintenance Manual READ AND SAVE THESE INSTRUCTIONS LIRE ET CONSERVER CES INSTRUCTIONS
More informationProduct Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology
Product Data 58CLA Low-Boy Oil Furnace Series 110 Input Capacities: 70,000 thru 154,000 Btuh The Latest in Oil Furnace Technology The model 58CLA combines high efficiency and quiet operation with oil heating
More informationSeries PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection
Series PIC New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction and Renovation; Replaces
More informationProduct Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input
Product Data 58EFA Horizontal Gas Furnace 50,000 125,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the
More information1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series
1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor
More informationSubmittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat
SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT WITH PURON R (R-410A) REFRIGERANT ONE STAGE COOLING CAPACITY CONTROL: SIZES 08-12 TWO STAGE COOLING CAPACITY CONTROL: SIZES 08, 12 & 14 Submittal
More informationFLOW-THROUGH FURNACE HUMIDIFIER
FLOW-THROUGH FURNACE HUMIDIFIER Model 5000/6000 Warranty Maintenance Troubleshooting Guide 2 WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE WARRANTY The manufacturer guarantees the for the period of one year
More informationProduct Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY
MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH Product Data THE LATEST IN OIL FURNACE TECHNOLOGY A10311 The models OBM and OVM combine high efficiency and quiet operation with oil heating
More information350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40.
HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE 350MAV Sizes 040 thru 140 Series D Utilizing the extensive resources available to Bryant, a new standard of excellence
More information