GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A)
|
|
- Julius Riley
- 5 years ago
- Views:
Transcription
1 GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A) HVAC SERVICE PARTS Supersedes: Rev. A (0904) Rev. B (0205) 1 of 8 Figure 1: UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACES (90%) FIG ITEM DESCRIPTION GM9V040A12UP11A GM9V060B12UP11A GM9V080B12UP11A (2 BURNER) (3 BURNER) (4 BURNER) MOTOR 2 1 MOTOR, DIRECT DRIVE BLOWER ,2 2 MOTOR, INDUCER ASSY ELECTRICAL 1,2 3 CFM SELECTOR BOARD SWITCH, LIMIT (INDUCER) ,2 5 CONTROL, HIGH LIMIT CONTROL,FLAME ROLL OUT ,2 7 CONTROL,FURNACE * 7A FUSE ,2 8 SWITCH, AIR PRESSURE IGNITER SENSOR, FLAME SWITCH, DOOR TRANSFORMER VALVE, GAS AIR MOVING 2 14 HOUSING, BLOWER WHEEL, BLOWER New replacement parts shown in bold face type at the first printing of parts list dated 2/05. Unitary Products Group
2 Rev. B (0205) 2 of 8 Figure 2: UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACES (90%) FIG ITEM DESCRIPTION GM9V040A12UP11A GM9V060B12UP11A GM9V080B12UP11A (2 BURNER) (3 BURNER) (4 BURNER) FABRICATED PARTS 2 16 MOUNT, MOTOR COIL, CONDENSING SHELF, BLOWER BURNER, GAS * 20 BRACKET, BLOWER SHELF HEAT EXCHANGER ASS Y PANEL, BLOCK-OFF A BASE FRAME, SIDE (2 Req d) MANIFOLD, GAS DOOR, VEST ACCESS DOOR, BLOWER ACCESS WRAPPER, INSULATED < 1 27 CHANNEL, TOE PLATE PLATE DIFFUSER ,3 29 COVER, GAS CONTROL BURNER BOX, BOTTOM PANEL PANEL, TOP SUPPORT, BURNER WRAPPER, BURNER BOX PANEL, ELECTRIC BRACKET, IGNITER PAN, SHIELD New replacement parts shown in bold face type at the first printing of parts list dated 205.
3 3 of Rev. B (0205) Figure 3: GAS CONTROLS - UPFLOW (90%) FIG ITEM DESCRIPTION GM9V040A12UP11A GM9V060B12UP11A GM9V080B12UP11A (2 BURNER) (3 BURNER) (4 BURNER) MISCELLANEOUS 2,3 39 CONNECTOR, AIR INTAKE * 40 FILTER, AIR (.75 X 16 X 25) RESTRICTOR, COMBUSTION BLWR GASKET, AIR INTAKE CONNECTOR GASKET, COMBUSTION BLOWER GASKET, CONDENSATE PAN GASKET, CONDENSING COIL (2 Req d) GASKET, GAS CONTROLS GASKET, UPPER COND. PAN GROMMET, MANIFOLD SEAL * 49 GROMMET, 1/ ,3 50 PLUG, WINDOW, CLEAR GROMMET, MOTOR MOUNT (3 Req d) FERRULE, MOTOR MOUNT (3 Req d) ,2 53 PAN, CONDENSATE ORIFICE, BURNER (Natural #45) * 55 RACK, FILTER ,2 56 TRAP, CONDENSATE * 57 WIRING DIAGRAM * 58 HARNESS, MAIN WIRING TUBE, DRAIN ASSY ,3 60 TUBE, PRE-FORMED TUBE, DRAIN, CONDENSATE TRAP TUBE, DRAIN COMBUSTION BLWR TUBE, SILICONE RUBBER (2 Ft. Req d) TUBE, DRAIN CONDENSATE PAN PIPE VENT ASSEMBLY HANDLE, DOOR * 67 BUSHING * 68 INSERT, ADAPTER * 69 LOCKNUT, 1/ * 70 REDUCER, 2 TO 1-1/ WASHER, FLAT FIBERGLASS (2 Req d) New replacement parts shown in bold face type at the first printing of parts list dated 2/05. Unitary Products Group
4 Rev. B (0205) 4 of 8 Figure 1: UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACES (90%) FIG ITEM MOTOR DESCRIPTION GM9V080C16UP11A GM9V100C20UP11A GM9V120D20UP11A (4 BURNER) (5 BURNER) (6 BURNER) 2 1 MOTOR, DIRECT DRIVE BLOWER ,2 2 MOTOR, INDUCER ASS Y ELECTRICAL 1,2 3 CFM SELECTOR BOARD SWITCH LIMIT, (Inducer) ,2 5 CONTROL, HIGH LIMIT CONTROL, FLAME ROLL OUT (2 ea) ,2 7 CONTROL, FURNACE * 7A FUSE ,2 8 SWITCH, AIR PRESSURE IGNITER SENSOR, FLAME SWITCH, DOOR TRANSFORMER VALVE, GAS AIR MOVING 2 14 HOUSING, BLOWER WHEEL, BLOWER New replacemnt parts shown in bold face type at the first printing of parts list code dated 2/05. Major components and suggested stockings items are shown with shaded item number.
5 5 of Rev. B (0205) Figure 2: UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACES (90%) GM9V080C16UP11A GM9V100C20UP11A GM9V120D20UP11A FIG ITEM DESCRIPTION (4 BURNER) (5 BURNER) (6 BURNER) FABRICATED PARTS 2 16 MOUNT, MOTOR COIL, CONDENSING SHELF, BLOWER BURNER, GAS * 20 BRACKET, BLOWER SHELF HEAT EXCHANGER ASS Y PANEL, BLOCK-OFF A BASE FRAME, SIDE (2 Req d) MANIFOLD, GAS DOOR, VEST ACCESS DOOR, BLOWER ACCESS WRAPPER, INSULATED < 1 27 CHANNEL, TOE PLATE PLATE DIFFUSER ,3 29 COVER, GAS CONTROL BURNER BOX, BOTTOM PANEL PANEL, TOP SUPPORT, BURNER WRAPPER, BURNER BOX PANEL, ELECTRIC BRACKET, IGNITER PAN, SHIELD New replacement parts shown in bold face type at the first printing of parts list dated 2/05. Unitary Products Group
6 Rev. B (0205) 6 of 8 Figure 3: GAS CONTROLS - UPFLOW (90%) FIG ITEM DESCRIPTION GM9V080C16UP11A GM9V100C20UP11A GM9V120D20UP11A (4 BURNER) (5 BURNER) (6 BURNER) MISCELLANEOUS 2,3 39 CONNECTOR, AIR INTAKE * 40 FILTER, AIR (.75 X 16 X 25) RESTRICTOR, COMBUSTION BLWR GASKET, AIR INTAKE CONNECTOR GASKET, COMBUSTION BLOWER GASKET, CONDENSATE PAN GASKET, CONDENSING COIL (2 Req d) GASKET, GAS CONTROLS GASKET, UPPER COND. PAN GROMMET, MANIFOLD SEAL * 49 GROMMET, 1/ ,3 50 PLUG, WINDOW, CLEAR GROMMET, MOTOR MOUNT (3 Req d) FERRULE, MOTOR MOUNT (3 Req d) ,2 53 PAN, CONDENSATE ORIFICE, BURNER (Natural #45) * 55 RACK, FILTER ,2 56 TRAP, CONDENSATE * 57 WIRING DIAGRAM * 58 HARNESS, MAIN WIRING TUBE, DRAIN ASSY ,3 60 TUBE, PRE-FORMED TUBE, DRAIN, CONDENSATE TRAP TUBE, DRAIN COMBUSTION BLWR TUBE, SILICONE RUBBER (2 Ft. Req d) TUBE, DRAIN CONDENSATE PAN PIPE VENT ASSEMBLY HANDLE, DOOR * 67 BUSHING * 68 INSERT, ADAPTER * 69 LOCKNUT, 1/ * 70 REDUCER, 2 TO 1-1/ WASHER, FLAT FIBERGLASS (2 Req d) New replacement parts shown in bold face type at the first printing of parts list dated 2/05.
7 7 of Rev. B (0205) FIELD INSTALLED ACCESSORIES - NON-ELECTRICAL MODEL NO. DESCRIPTION USED WITH 1NP0580 PROPANE (LP) CONVERSION KIT ALL MODELS 1SF0101 EXTERNAL SIDE FILTER RACK ALL MODELS 1CT0302 CONCENTRIC INTAKE/VENT 2 40, 60, 80, 100 INPUT MBH 1CT0303 CONCENTRIC INTAKE/VENT 3 100, 120 MBH 1PS0501 1PS0502 1PS0503 1PS0504 1PS0505 1PS0506 1BR0314 1BR0317 1BR0321 1BR0324 HIGH ALTITUDE PRESSURE SWITCH KIT (Does Not Include Orifices) FOR APPLICATION INFORMATION SEE instructions 14-1/2 CABINETS EXTERNAL BOTTOM FILTER RACK 17-1/2 CABINETS 21 CABINETS 24-1/2 CABINETS 1NK0301 CONDENSATE NEUTRALIZER KIT ALL MODELS 1SF0101 EXTERNAL SIDE RETURN FILTER RACK ALL MODELS 1HT0901 SIDEWALL VENT TERMINATION KIT ALL MODELS FIELD INSTALLED ACCESSORIES - ELECTRICAL MODEL NO. DESCRIPTION USED WITH 6TH THERMOSTAT- Heating, One-stage Heat, No Fan Switch. ALL MODELS 6TH THERMOSTAT- Heating / Cooling, One-stage Heat / Cool. Manual changeover. ALL MODELS Unitary Products Group
8 8 of 8 TO ORDER AUTHORIZED FACTORY REPLACEMENT PARTS - Contact your Source1 HVAC Parts Distributor or visit our website at for a Distributor and Dealer listing. Subject to change without notice. Printed in U.S.A Rev. B (0205) Copyright by York International Corp All rights reserved. Supersedes: Rev. A (0904) Unitary 5005 Norman Products York OK Group Drive 73069
FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A)
www.source1parts.com HVAC SERVICE PARTS FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A) Supersedes: 035-20615-001 Rev. C (1004) 035-20615-001 Rev. D (0507) 1 of 8
More informationPT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A)
www.source1parts.com HVAC SERVICE PARTS PT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A) Supersedes: 035-20487-001 Rev. C (1004) 035-20487-001 Rev. D (1014) 1 of 8 31 65 24 5 8 53 63 35
More informationPS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90%
PS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90% HVAC SERVICE PARTS Supersedes: 035-20437-001 Rev. C (1004) 035-20437-001 Rev. D (1204) 1 of 8 Figure 1: UPFLOW 1-STAGE NATURAL GAS FURNACES (90%) FIG
More informationPS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%
PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20712-001 Rev. B (1005) 035-20712-001 Rev. C (1105) 1 of 12 Figure 1: UPFLOW NATURAL GAS FURNACES (90%) FIG ITEM
More informationPS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90%
PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90% www.source1parts.com HVAC SERVICE PARTS Supersedes: 035-21082-001 Rev. A (1205) 035-21082-001 Rev. B (1106) 1 of 12 31 29 5 61 26 10 39 69 12 11 16
More informationFC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C)
www.source1parts.com HVAC SERVICE PARTS FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C) Supersedes: 035-21088-001 Rev. B (0806) 035-21088-001 Rev. C (0507) 1 of 8 31
More informationGM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%
GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20716-001 Rev. A (0205) 035-20716-001 Rev. B (1005) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES
More informationGM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K)
GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K) www.source1parts.com HVAC SERVICE PARTS Supersedes: Nothing 035-21295-001 Rev. A (1206) 1 of 12 31 29 26 5 10 39 69 24 11 12 16 58 61 40 13
More informationGM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J)
www.source1parts.com HVAC SERVICE PARTS GM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J) Supersedes: 035-21080-001 Rev. D (0207) 035-21080-001 Rev. E (0507) 1 of 12 31 29 26 5 10 39 69 24 11
More informationFL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A)
www.source1parts.com HVAC SERVICE PARTS FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A) Supersedes: 035-21211-001 Rev. C (1106) 035-21211-001 Rev. D (0708) 1 of 8 33 31 5 10 41
More informationGF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G)
www.source1parts.com HVAC SERVICE PARTS 32 GF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G) Supersedes: 035-20372-001 Rev. D (0205) 035-20372-001 Rev. E (0507) 74 1 of 12 Figure 1: UPFLOW CONDENSING
More informationPT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%
PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20714-001 Rev. C (1005) 035-20714-001 Rev. D (1105) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES
More informationGM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B)
www.source1parts.com HVAC SERVICE PARTS GM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B) Supersedes: 035-21326-001 Rev. A (0207) 035-21326-001
More informationPT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A)
PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A) HVAC SERVICE PARTS Supersedes: 035-20700-001 Rev. B (0805) 035-20700-001 Rev. C (1105) 1 of 8 Figure 1: DOWNFLOW/HORIZONTAL 2-STAGE
More informationFC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B)
www.source1parts.com HVAC SERVICE PARTS FC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B) Supersedes: Nothing, See Back 035-21322-001 Rev.
More information2 STAGE UPFLOW NATURAL GAS FURNACES (94+)
2 STAGE UPFLOW NATURAL GAS FURNACES (94+) HVAC SERVICE PARTS Supersedes: 035-17482-000 Rev. E (1102) 035-17482-000 Rev. F (0304) 1 of 8 Figure 1: 2-STAGE UPFLOW NATURAL GAS FURNACES (94+) P1XUB12N05501
More informationPC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A)
www.source1parts.com HVAC SERVICE PARTS PC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A) Supersedes: 035-214-001 Rev. B (0706) 035-214-001 Rev. C (1006)
More informationUPFLOW NATURAL GAS FURNACES - 90%
Y W R G C UPFLOW NATURAL GAS FURNACES - 90% www.source1parts.com HVAC SERVICE PARTS Supersedes: 035-17489-000 Rev. C (1201) 035-17489-000 Rev. D (302) 1 of 8 13 5 8 10 4 2 9 6 14 11 1 COOL HEAT CIR 12
More informationFG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%)
FG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%) www.source1parts.com HVAC SERVICE PARTS Supersedes: 650.75-RP1U (1199) 035-17790-001 Rev. A (1102) 1 of 8 13 5 9 8 61 6 10 4 2 11 12 7 3 16 1 14 15
More information2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%)
2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%) INCLUDING LO-NOX (See Page 6) HVAC SERVICE PARTS Supersedes: 035-17432-000 Rev. B (1201) 035-17432-000 Rev. C (0304) 1 of 8 Figure
More informationPT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES
www.source1parts.com HVAC SERVICE PARTS PT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES (STYLE D, Some B) INCLUDING LO-NOX MODELS Supersedes: Nothing 035-21348-001 Rev. A (0307) 1 of 8 8
More informationFC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%)
FC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) INCLUDING LO-NOX (MODEL LC8) (STYLE B) HVAC SERVICE PARTS Supersedes: 035-20671-001 Rev. C (0605) 035-20671-001 Rev. D (1105) 1 of 8 Figure
More informationTG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)
www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. A (0313) 035-23623-001 Rev. B (0613) 26 1 of 6 44
More informationTG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)
www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. H (1115) 035-23623-001 Rev. J (1117) 26 1 of 6 44
More informationP3HU - UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) (STYLES A & B, INCLUDING LOW NOX)
www.source1parts.com HVAC SERVICE PARTS PHU - UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (0%) (STYLES A & B, INCLUDING LOW NOX) Supersedes: 0-1-000 Rev. C (06) 0-1-000 Rev. D (0) 1 of 1 1 1 1 1 6,0 Figure
More informationTG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS
www.source1parts.com HVAC SERVICE PARTS 41 TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS Supersedes: 035-21389-001 Rev. K (0410) 035-21389-001
More informationP1DD AND G8D 2-STAGE DOWNFLOW - NATURAL GAS FURNACES (80%)
P1DD AND G8D 2-STAGE DOWNFLOW - NATURAL GAS FURNAES (80%) HVA SERVIE PARTS Supersedes: 035-17433-000 Rev. (0404) 035-17433-000 Rev. D (0604) 1 of 8 Figure 1: 2-STAGE DOWNFLOW NATURAL GAS FURNAES (80%)
More informationAHP SERIES SINGLE PIECE AIR HANDLER R-22 TXV AND FLEX COIL MODELS (STYLE A&B)
www.source1parts.com AHP SERIES SINGLE PIECE AIR HANDLER R-22 TXV AND FLEX COIL MODELS (STYLE A&B) HVAC SERVICE PARTS Supersedes:03-21126-001 Rev. E (0408) 03-21126-001 Rev. F (0609) 1 of 8 12 4 3 6 7
More informationTECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.
036-1349-001 Rev. A (30) Heating TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 9 AFUE NATURAL GAS 37-130 MBH OUTPUT Air Conditioning EFFICIENCY RATING CERTIFIED R
More informationTECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES
036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING
More informationDDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B)
www.source1parts.com HVAC SERVICE PARTS DDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B) Supersedes:035-23383-001 Rev. A (1211) 035-23383-001 Rev. B (0112) 1 of 14
More informationPAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)
www.source1parts.com HVAC SERVICE PARTS PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) Supersedes:035-21137-001 Rev. E (1107) 035-21137-001 Rev. F (0611) 1 of 8 CONDENSER ROOF (SEE
More informationTECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE
TEHNIAL GUIDE Acclimate MODELS: FL9S GAS-FIRED ONDENSING / HIGH EFFIIENY UPFLOW SINGLE STAGE FURNAES 92% AFUE NATURAL GAS 40-135 MBH INPUT EFFIIENY RATING ERTIFIED ISO 9001 ertified Quality Management
More informationGUH & GDD SERIES REPLACEMENT PARTS LIST SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE. GUH92A Upflow / Horizontal
REPLACEMENT PARTS LIST GUH & GDD SERIES SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES NON-CONDENSING GAS FURNACES CONDENSING GAS FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE GUH80A Upflow / Horizontal
More informationUSER S INFORMATION, MAINTENANCE AND SERVICE MANUAL
USER S INFORMATION, MAINTENANCE AND SERVICE MANUAL MODELS: PC9 (Modulating Downflow/Horizontal With ECM Motor) EFFICIENCY RATING CERTIFIED ISO 9001 Certified Quality Management System CONTACT INFORMATION................................
More informationSECTION I: USER S INFORMATION
USER S INFORMATI, MAINTENANCE AND SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: GY9S*UP / GM9S*UP / GF9S*UP (Single Stage Upflow) EFFICIENCY RATING CERTIFIED ISO 9001 Certified Quality
More informationSECTION I: USER S INFORMATION
USER S INFORMATI, MAINTENANCE AND SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: PV9*UP / FC9V*UP / FL9V*UP (Two Stage Variable Speed Upflow) EFFICIENCY RATING CERTIFIED ISO 9001
More informationMASTERTEMP HEATER REPLACEMENT PARTS
0 Section. Maintenance/Replacement Parts Electrical System (Key Nos. through 4), See Page 2 Burner System (Key Nos. through ), See Page 4 Water System (Key Nos. through ), see Page 2 Repair Parts are available
More informationCOOKTOP, BURNER AND GRATE PARTS For Model: JDRP430WP00 (Stainless)
COOKTOP, BURNER AND GRATE PARTS 30" Commercial Style Range 8 10 Litho in U.S.A. (amd)(bay) 1 Part No. Rev. A COOKTOP, BURNER AND GRATE PARTS 1 Literature Parts Tech Sheet W10294839 English W10294843 French
More informationTZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )
FORM NO. GTZ-540 Supersedes Form No. GTZ-503 Rev. 1 TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] (All Models 95% A.F.U.E. ) TWO STAGE VARIABLE SPEED MULTI POSITION GAS
More informationTZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )
FORM NO. GTZ-538 Supersedes Form No. GTZ-503 Rev. 1 TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 95% A.F.U.E. ) 95% A.F.U.E. MULTI POSITION GAS FURNACES Features
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE
More informationG71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped
More informationSECTION I: USER S INFORMATION
USER S INFORMATI, MAINTENANCE AND SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: PV9 / FC9V / FL9V (Two Stage Variable Speed Downflow/Horizontal) EFFICIENCY RATING CERTIFIED ISO 9001
More informationRuud Achiever Series Multi position Gas Furnaces
Gas Furnaces Ruud Achiever Series Multi position Gas Furnaces R92P- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationW92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )
FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential
More informationFORM NO. G REV. 4 Supersedes Form No. G Rev. 3
FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace
More informationREPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF "A" Series 15 SEER Models
REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF "A" Series 15 SEER Models IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper repair
More informationCOMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES
FORM NO. GSC-493 REV. 3 Supersedes Form No. GSC-493 Rev. 2 GF902U*B SERIES Models with Input Rates of 45,000, 60,000, 75,000, 90,000 & 105,000 BTU/HR [13.19, 17.58, 22, 26.38 & 30.77 kw] 90 PLUS WITH DUAL
More informationTZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )
FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features
More informationCOOKTOP, BURNER AND GRATE PARTS For Model: JGRP430WP01 (Stainless)
COOKTOP, BURNER AND GRATE PARTS 30" Commercial Style Range 7 11 Litho in U.S.A. (amd) (psw) 1 Part No. Rev. A COOKTOP, BURNER AND GRATE PARTS 1 Literature Parts Tech Sheet W10403308 English W10403309 French
More informationOWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES
OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES TABLE OF CONTENTS HOW YOUR GAS FURNACE WORKS...................... 2 KEEP THE FURNACE AREA CLEAR....................... 2 SFOR YOUR SAFETY,
More informationGAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)
FORM NO. G22-482 REV. 8 Supersedes Form No. G22-482 Rev. 7 GAS FURNACES RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above) 90 PLUS WITH DUAL COMFORT CONTROL
More informationKG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace
More informationG I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY
G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S NATURAL GAS 60-120 MBH INPUT Due to continuous product improvement, specifications are subject to change
More informationMULTI POSITION GAS FURNACE
FORM NO. GFJ-537 MULTI POSITION GAS FURNACE FF***PS95 Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 95% residential gas furnace CSA certified 4 way multi-poise design
More informationMulti-Position Gas Furnaces
MODEL: Multi-Position Gas Furnaces FORM NO. GSC-552 Rev. 1 Sure Comfort 92% A.F.U.E. Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] 92% residential gas furnace
More informationThis parts list is current as of the above revision date. See for the current revision.
URM- Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-urm-.pdf for the current revision. Package Gas-Electric Table of Contents Model Explanation...................................................................................................................
More informationUSER S INFORMATION, MAINTENANCE AND SERVICE MANUAL
USER S INFORMATION, MAINTENANCE AND SERVICE MANUAL MODELS: G8C/ GF8 (Single Stage Multi-Position) EFFICIENCY RATING CERTIFIED ISO 9001 Certified Quality Management System CONTACT INFORMATION...............................
More informationREPAIR PARTS. GCVC 80% 2-Stage Variable Speed Downflow Horizontal Furnace. This manual is to be used by qualified technicians only.
REPAIR PARTS GCVC 80% 2-Stage Variable Speed Downflow Horizontal Furnace GCVC80603BXBC GCVC80803BXBC GCVC80805CXBC GCVC81005CXBC This manual is to be used by qualified technicians only. 2016 Goodman Manufacturing
More informationCooling Capacity CFM range
R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Cabinet air leakage less than 2.0% at 1.0 in. W.C. and
More informationCooling Capacity CFM in. w.c. (125 Pa)
R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning
More informationMULTI POSITION GAS FURNACE
FORM NO. GFJ-552 MULTI POSITION GAS FURNACE 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 92% residential gas furnace CSA certified 4 way multi-poise design 7-Segment LED all
More information90 HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. GSC-497 REV. 2 Supersedes Form No. GSC-497 Rev. 1 GF901U SERIES Models with Input Rates 45,000, 60,000, 105,000 & 120,000 BTU/HR [13.19, 17.58, 30.77, & 35.17 kw] (All Models 90% A.F.U.E. or Above)
More informationGAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES
FORM NO. G11-493 REV. 5 Supersedes Form No. G11-493 Rev. 4 GAS FURNACES RGRL- SERIES Models with Input Rates of 45,000, 60,000, 75,000 & 90,000 BTU/HR [13.19, 17.58, 22, & 26.38 kw] 90 PLUS WITH DUAL COMFORT
More informationParts List for Ener-Radiant XL Tube Heaters
Parts List for Ener-Radiant XL Tube Heaters ERXL-0 F09XL ERXL-0 NG / BRN & Cont Box 0 Front Flange F09XL ERXL-0 LP / BRN & Cont Box 009 Reflector End Cap F00XL Tube Set- 0' 099 Spring Clips 0 Tube H.E.
More informationGV Series 4 Section Assembly
GV Series 4 Section Assembly 192 Current Service Parts GV Series 4 Section Assembly Fig. No. Part No. Description Size Notes 1 322-200-280 Section Assembly, GV-3 (Repair Kit Required) 3 1 322-200-281 Section
More informationG60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with
More informationRP8.1Y (ERRATA 1) (202) 2 of 8
530.18-RP8.1Y (ERRATA 1) (202) 2 of 8 ELECTRICAL (Cont.) FIG ITEM DESCRIPTION D6CG048N06006A D6CG048N06025A D6CG048N06046A D6CG048N06058A 3-BURNER 3-BURNER 3-BURNER 3-BURNER * 15 CONNECTOR, CAP (9-CIRCUIT)
More informationGAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G66-452 REV. 3 Supersedes Form No. G66-452 Rev. 2 GAS FURNACES WGTA- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (U.S. & Canadian Models) (All Models 90% A.F.U.E.
More informationRheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces
Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] All Models except R96VA085
More informationSeries Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.
Gas Furnaces Ruud Achiever Plus Series Two- Stage Multi-position Gas Furnaces - Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationUltra Boiler Series 1 & 2 Jacket Parts
GAS Ultra Boiler Series 1 & 2 Jacket Parts 9 10 8 6 7 1 5 2 3 Fig. Part Description Model Mfr. 1 383-500-135 Jacket Front Door 595-000-000 595-000-001 595-000-002 595-000-003 Panel Door Jacket Plastic
More informationRheem Classic Series Multi-position Gas Furnaces
Gas Furnaces Rheem Classic Series Multi-position Gas Furnaces R95P- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE
More informationMulti-Position Gas Furnaces
MODEL: S96VA Multi-Position Gas Furnaces FORM NO. GSC-540 REV. 5 Sure Comfort S96VA 96% A.F.U.E. Two-Stage Variable Speed Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72
More informationGAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. G11-503 REV. 1 Supersedes Form No. G11-503 GAS FURNACES Visit www.rheem.com for complete details. RGRC- SERIES Model with Input Rates from 45,000 to 105,000 BTU/HR [13.19 to 30.77 kw] (All Models
More informationGAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G11-452 REV. 10 Supersedes Form No. G11-452 Rev. 9 GAS FURNACES RGTA- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) CLASSIC
More information90 HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. G66-477 Supersedes Form No. A11-152 Rev. 3 90 EFFICIENCY UPF GAS FURNACES 90RJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above)
More informationEffective october 14, 2014
COS-20G combi oven-steamer REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationRuud Achiever Plus Series Multi-position Gas Furnaces
Gas Furnaces Ruud Achiever Plus Series Multi-position Gas Furnaces R92T- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...
More informationGAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL
FORM NO. G11-499 Supersedes Form No. G11-499 GAS FURNACES RGFE- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kw] (All Models 92% A.F.U.E. or Above) Equipped with Comfort
More informationUpflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace
Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA
More informationWt. Lbs Model Number (BTUH) Hz
Up to 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions F95% AFUE in downflow position California NOx approved Most models have earned the ENERGY STAR
More informationGAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. G11-450 REV. 13 Supersedes Form No. G11-450 Rev. 12 GAS FURNACES /RGRB- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) CLASSIC
More informationReplacement Parts List For Models COS-20G
Replacement Parts List For Models COS-20G (Ovens with s/n HP & HT) Contents: Page # Electrical Compartment:Contactors,Steam Generator,Thermostats 2-5 Oven Interior: 5 Bottom Section: Gas, Plumbing Components
More information90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G11-498 REV. 5 Supersedes Form No. G11-498 Rev. 4 RGTS- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/
More informationRheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces
Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel
More informationGAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.
FORM NO. G11-468 REV. 15 Supersedes Form No. G11-468 Rev. 14 GAS FURNACES Visit www.rheemac.com/ taxcredit for complete details. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58
More informationRheem Classic Plus Series Two Stage Multi position Gas Furnaces
Gas Furnaces Rheem Classic Plus Series Two Stage Multi position Gas Furnaces R96P- Series 96% A.F.U.E. * Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)
More informationReplacement Parts List
Replacement Parts List SINGLE PACKAGE AIR CONDITIONER GENERATION 4 42 CABINET Note: This is a non-comprehensive parts list intended for stocking purposes for first production (style A) units based on current
More informationUSER S INFORMATION, MAINTENANCE AND SERVICE MANUAL
USER S INFORMATI, MAINTENANCE AND SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: GY8S / GM8S / LY8S / LM8S / LF8 (Single Stage Upflow / Horizontal / LoNOx) EFFICIENCY RATING CERTIFIED
More informationProduct Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING
DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S
More informationFSB Series II Gas-Fired Hot Water Induced Draft Boilers
FSB Series II Gas-Fired Hot Water Induced Draft Boilers Models FSB- FSB-3 FSB-4 FSB-5 FSB-6 FSB-7 REPAIR PARTS AND OPTIONAL KITS Ordering Instructions Order Parts through your nearest supplier. When ordering
More informationFG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage
More information90 HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. G11-497 REV. 4 Supersedes Form No. G11-497 Rev. 3 RGRS/RGRT- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY UPF
More informationPower Direct Vent PDV(S&T) Models
COMMERCIAL REPLACEMENT PARTS LIST Power Direct Vent PDV(S&T) Models Includes Hydrojet Total Performance System Effective: January, 2012 ECO 7731 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING
More informationCOMMUNICATING TWO-STAGE VARIABLE SPEED MULTI-POSITION GAS FURNACES
FORM NO. GFJ-540 COMMUNICATING TWO-STAGE VARIABLE SPEED MULTI-POSITI GAS FURNACES 96% A.F.U.E. Input Rates from 60 to 115 kbtu [11.72 to 33.71 kw] Manufactured for Fujitsu General America, Inc. Fairfield,
More informationCOOKTOP, BURNER AND GRATE PARTS For Model: JGRP548WP00 (Stainless)
COOKTOP, BURNER AND GRATE PARTS 48" Stainless Commercial Style Range 8 10 Litho in U.S.A. (amd) (psw) 1 Part No. Rev. B COOKTOP, BURNER AND GRATE PARTS 1 Literature Parts Tech Sheet W10323236 English W10323237
More information