TEST REPORT: CHM14-05-CHY

Size: px
Start display at page:

Download "TEST REPORT: CHM14-05-CHY"

Transcription

1 A TEST REPORT: CHM14-05-CHY Date: Tel: Fax: Client s Ref: huayi.chen@tuv-sud-psb.sg Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD PSB Pte Ltd. In addition, this report is governed by the terms set out within this report. SUBJECT Naturion Ioniser NA50 Performance of Ozone Emission CLIENT Serumi International Private Limited 36 Armenian Street #02-02 Singapore Attn: Mr Sean Gan PY TEST DATE 16 Mar 2015 DESCRIPTION OF IONISER The photograph and specifications of Naturion Ioniser NA50 were listed in Annex A. METHOD OF TEST The Naturion Ioniser NA50 was tested in a 1 m 3 chamber (Annex B). The Naturion Ioniser NA50 was fixed on a Fan. The Fan generates wind through a short channel. The Naturion Ioniser NA50 was then fixed on the end of channel. An ozone sensor was installed in front of the Naturion Ioniser NA50 with a distance of 10 cm to monitor ozone concentration. Ozone concentration was recorded by every 1 minute during a 30 minutes period. Laboratory: TÜV SÜD PSB Pte. Ltd. No.1 Science Park Drive Singapore Phone : Fax : testing@tuv-sud-psb.sg Co. Reg : R Regional Head Office: TÜV SÜD Asia Pacific Pte. Ltd. 3 Science Park Drive, #04-01/05 The Franklin, Singapore

2 RESULTS Table 1 Monitored ozone concentrations in background and during Naturion Ioniser NA50 operation Time, Minutes Ozone, ppm background Ozone, ppm Naturion Ioniser NA50 operated NEA guidelines for Good Indoor Air Quality in Office Premises", Ozone Accepted Limit ppm SS554:2009 Indoor Air Quality for Air-conditioned Buildings, Table 2, Ozone Accepted Limit, ppm 0 ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < ND ND < 0.05 < 0.1 Remark: ND not detected (detection limit 0.01 ppm) Page 2 of 6

3 SUMMARY The NEA guidelines and SS554 were referred to evaluate ozone emission from Naturion Ioniser NA50. Ozone was not detected at the detection limit of 0.01 ppm during Naturion Ioniser NA50 s 30 minutes operation time at a distance of 10 cm away from the ioniser. The NA50 ozone emission meets the ozone accepted limit of less than 0.05 ppm in NEA guidelines for Good Indoor Air Quality in Office Premises" and ozone accepted limit of less than 0.1 ppm in Table 2 of Singapore Standard SS554:2009 Indoor Air Quality for Air conditioned Buildings. DR. YANG LEI EXECUTIVE CONSULTANT DR CHEN HUAYI ASSISTANT VICE PRESIDENT CHEMICAL CENTRE Page 3 of 6

4 Annex A: Naturion Ioniser NA50 Specifications (Provided by Serumi International Private Limited) Name Naturion Ioniser NA50 Photograph Negative ions count Power supply Net Weight Unit dimensions Unit with clip dimensions Packaging dimensions Max pcs/cm 3 (at 100 cm distance) DC 12V 43 g mm mm mm Page 4 of 6

5 Annex B: Schematic of test chamber Ozone meter NA50 Wind direction Figure Schematic layout of the test chamber (1 1 1 meter) Page 5 of 6

6 Please note that this Report is issued under the following terms : 1. This report applies to the sample of the specific product/equipment given at the time of its testing/calibration. The results are not used to indicate or imply that they are applicable to other similar items. In addition, such results must not be used to indicate or imply that TÜV SÜD PSB approves, recommends or endorses the manufacturer, supplier or user of such product/equipment, or that TÜV SÜD PSB in any way guarantees the later performance of the product/equipment. Unless otherwise stated in this report, no tests were conducted to determine long term effects of using the specific product/equipment. 2. The sample/s mentioned in this report is/are submitted/supplied/manufactured by the Client. TÜV SÜD PSB therefore assumes no responsibility for the accuracy of information on the brand name, model number, origin of manufacture, consignment or any information supplied. 3. Nothing in this report shall be interpreted to mean that TÜV SÜD PSB has verified or ascertained any endorsement or marks from any other testing authority or bodies that may be found on that sample. 4. This report shall not be reproduced wholly or in parts and no reference shall be made by the Client to TÜV SÜD PSB or to the report or results furnished by TÜV SÜD PSB in any advertisements or sales promotion. 5. Unless otherwise stated, the tests were carried out in TÜV SÜD PSB Pte Ltd, No.1 Science Park Drive Singapore July 2011 Page 6 of 6

TEST REPORT: CHM14-07-CHY

TEST REPORT: CHM14-07-CHY A TEST REPORT: 7191100863-CHM14-07-CHY Date: Tel: +65 68851291 Fax: +65 67784301 Client s Ref: Email: huayi.chen@tuv-sud-psb.sg Note: This report is issued subject to the Testing and Certification Regulations

More information

Technical Report No. CPSA Rev. 00 Dated Test according to the test specification Evaluation and categorization

Technical Report No. CPSA Rev. 00 Dated Test according to the test specification Evaluation and categorization Client: IZEN Co., Ltd. 242, Aegibong-ro, Wolgot-myeon Gimpo-si, Gyeonggi-do 415-873 REPUBLIC OF KOREA Contact Person: ISA AC Kim Tel.: +82-31-999-7300, 070-4705-1878 Fax.: +82-31-997-3147 Manufacturing

More information

Test Report No EEC12/08 dated 18 Jun 2012

Test Report No EEC12/08 dated 18 Jun 2012 Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD PSB Pte Ltd. In addition, this report is

More information

ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES

ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES In accordance to the ASEAN Sectoral MRA for Electrical and Electronic Equipment,

More information

Test Report. Appliance EMF Testing

Test Report. Appliance EMF Testing Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is

More information

Our Ref: SCDF/HAZ/14/03/02/01 DID: FAX: REVIEW ON USE OF HYDROCARBON REFRIGERANT IN SINGAPORE

Our Ref: SCDF/HAZ/14/03/02/01 DID: FAX: REVIEW ON USE OF HYDROCARBON REFRIGERANT IN SINGAPORE Our Ref: SCDF/HAZ/14/03/02/01 DID: 68483312 FAX: 68483318 6 th December 2011 See Distribution Dear Sir/Madam, REVIEW ON USE OF HYDROCARBON REFRIGERANT IN SINGAPORE Since September 2009, a multi-agencies

More information

FIRE TESTING SERVICES FIRE TESTING SER

FIRE TESTING SERVICES FIRE TESTING SER FIRE TESTING SERVICES At TUV SUD PSB, we have a fire testing laboratory that was established since the late 70 s. We provide fire tests and inspection services for various industries, both locally and

More information

SmartSensor 105 & Advance NEMA External Ice

SmartSensor 105 & Advance NEMA External Ice SmartSensor 105 & Advance NEMA External Ice Test Report Wavetronix products mentioned: SmartSensor 105 SmartSensor Advance As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA external

More information

Channel Safety Systems Limited Unit 9, Petersfield Business Park Bedford Road Petersfield GU32 3QA UK. Authority & date SMO /04/2014

Channel Safety Systems Limited Unit 9, Petersfield Business Park Bedford Road Petersfield GU32 3QA UK. Authority & date SMO /04/2014 Test Report Report No Client Channel Safety Systems Limited Unit 9, Petersfield Business Park Bedford Road Petersfield GU32 3QA UK Authority & date SMO 8149837 07/04/2014 Items tested CDA/CO/1 - RESitech-

More information

Our Ref: CD/FSSD/12/02/03/01 DID: FAX:

Our Ref: CD/FSSD/12/02/03/01 DID: FAX: Our Ref: CD/FSSD/12/02/03/01 DID: 68481407 FAX: 68481493 14 Jan 2010 Registrar, Board of Architects (BOA) Registrar, Professional Engineers Board (PEB) President, Singapore Institute of Architects (SIA)

More information

TEMPORARY IMMERSION AND DUST TEST REPORT

TEMPORARY IMMERSION AND DUST TEST REPORT Report No. :DH1510130042A Version:A TEMPORARY IMMERSION AND DUST TEST REPORT Company Address :GradConn Ltd. :No. 139 Wuhan Rd., Longtan Township, Taoyuan County, Taiwan Sample Name :Refer to see page 2

More information

EMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD. Car DVD/Navigation Player

EMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD. Car DVD/Navigation Player EMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD Car DVD/Navigation Player Model No.: DT-063F, DT-0637, DT-0635, DT-0633, DT-0632, DT-0663, DT-063H, NAV-CF 8000 Prepared for : HUIZHOU FREEWAY ELECTRONIC

More information

Country Report for Solomon Islands

Country Report for Solomon Islands IIEC International Institute for Energy Conservation Country Report for Solomon Islands Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon

More information

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Ad-hoc IEC 60331-2 x Ad-hoc investigation

More information

We Identify and S.T.O.P. Your Noise Problems

We Identify and S.T.O.P. Your Noise Problems ASTM E-84 TESTING FOR MANUFACTURER, RENDERED TO: Acoustical Surfaces Inc. 123 Columbia Court North, Suite 201 Chaska, MN 55318 Noise S.T.O.P. Fabrisorb Acoustical Wall Panels TESTED: OCTOBER 3, 2002 October

More information

ENGINEERING EVALUATION

ENGINEERING EVALUATION ENGINEERING EVALUATION REPORT NUMBER: 100378137MID-002 ORIGINAL ISSUE DATE: April 26 th, 2011 REVISION AND DATE: Original EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Hanchett

More information

The smart handling of liquid chemicals: quickly connected safely dispensed.

The smart handling of liquid chemicals: quickly connected safely dispensed. The smart handling of liquid chemicals: quickly connected safely dispensed. Now you can bid farewell to the hazards of conventional drum emptying. ESCAPING GAS! Escaping gases, vapours and particulates

More information

Review Fire Test Report

Review Fire Test Report Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Review Fire Test Report Determination of

More information

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT No. 588 West Jindu Road, Songjiang District, Shanghai, China Telephone: +86 (0) 21 61915666 Fax: +86 (0) 21 61915678 ee.shanghai@sgs.com Page 1 of 8 1 Cover Page Application No.: Applicant: FCC MPE REPORT

More information

A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism

A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism Object A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism 2153-16 Type TCB 145-40-31 Serial No. 16000702, 16000703

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 61347-2-13 Part 2: Particular requirements: Section Thirteen d.c. or a.c.

More information

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07 RF TEST REPORT Applicant FCC ID Brand Product ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS Model VFD 511 Multi-Mode Digital Mobile Phone Report No. RXC1703-0087RF07 Issue Date May 24,2017 TA Technology

More information

The smart handling of liquid chemicals: quickly connected safely dispensed.

The smart handling of liquid chemicals: quickly connected safely dispensed. The smart handling of liquid chemicals: quickly connected safely dispensed. Now you can bid farewell to the hazards of conventional drum emptying. ESCAPING GAS! Escaping gases, vapours and particulates

More information

Technical-Report for SL Lamp 5 W

Technical-Report for SL Lamp 5 W Technical-Report for SL Lamp 5 W Technical Report No. 68.184.17.478.01 Dated 2017-06-27 Client: Manufacturing place: Name: PHOCOS China Ltd. Address: 3F 1st Bldg. 4A Chang Yi Road, 266021, Qingdao, PEOPLE'S

More information

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier Page 1 of 27 Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier Test Sponsor Saveguard (UK) Limited Warrington Fire Research Centre Ltd.,

More information

Acoustic Verification Report

Acoustic Verification Report Acoustic Verification Report Invacare XPO 2 Portable Oxygen Concentrator Type XPO100B-EU for Date: 2013-12-10 Our reference: IS-ATC2-MUC/js Document: Report Invacare VR.600010074.002.12 - Revision 2.docx

More information

LABORATORY REPORT GEOTECHNICAL / ENVIRONMEAL / MATERIALS ENGINEERS 3331 EAST WOOD STREET, PHOENIX, ARIZONA 85040 Physical Properties of Soils and Aggregates Client: Pace Pacific Corp. ATTN: Sean Moore

More information

Technical Note. Noise emission from Dehumidifier Type C65E TC Project no.: I Page 1 of July 2016

Technical Note. Noise emission from Dehumidifier Type C65E TC Project no.: I Page 1 of July 2016 Technical Note Noise emission from Dehumidifier Type C65E-11.1 Performed for COTES A/S Project no.: I101033 Page 1 of 10 01 July 2016 DELTA Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72 19 40 00 Fax

More information

COMMISSION ORDER. IT IS FURTHER ORDERED that the Request for Bid and Notice to Bidders be displayed on the Franklin County website.

COMMISSION ORDER. IT IS FURTHER ORDERED that the Request for Bid and Notice to Bidders be displayed on the Franklin County website. 4.e STATE OF MISSOURI County of Franklin ss. COMMISSION ORDER Commission Order No. 2016-316 Third Quarter Term 2016 Tuesday,August,09,2016 Bid Notice IN THE MATTER OF ADVERTISING FOR SEALED BIDS FOR SMOKE

More information

BRIDGE MONITORING. Picture 1: Benjamin Sheares Bridge

BRIDGE MONITORING. Picture 1: Benjamin Sheares Bridge BRIDGE MONITORING Opened in 1981, the Benjamin Sheares Bridge is the longest bridge in Singapore, spanning 1.8 km, and the tallest, at 20 m. It is named after Dr Benjamin Henry Sheares, the 2nd president

More information

COA-2010-F Electronic CO 2

COA-2010-F Electronic CO 2 COA-2010-F Electronic Analyzer New electronic analyzer specifically designed to monitor and temperature for the verification of in research and pharmaceutical markets. This unit has been developed to incorporate

More information

IMO Resolution MSC 61(67): Annex 1: Part 2

IMO Resolution MSC 61(67): Annex 1: Part 2 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com IMO Resolution MSC 61(67): Annex 1: Part

More information

Infrastructure Technology

Infrastructure Technology Registered Testing Authority - CSIRO 26 June 2014 Our Ref. EN13 / 2337 03/0212 TEST REPORT No. 7086.4s Requested by: Metro Tiles Pty Ltd 192 Granite Street Geebung QLD 4034 on (date): 24 June 2014 Manufacturer:

More information

Technical Note. Noise emission from Dehumidifier Type C35E-3.3 and Type C35E-5.6. TC Project no.: T Page 1 of 10.

Technical Note. Noise emission from Dehumidifier Type C35E-3.3 and Type C35E-5.6. TC Project no.: T Page 1 of 10. Technical Note Noise emission from Dehumidifier Type C35E-3.3 and Type C35E-5.6 Performed for COTES A/S TC-100902 Project no.: T211658 Page 1 of 10 15 January 2016 DELTA Venlighedsvej 4 2970 Hørsholm Denmark

More information

TEMPORARY IMMERSION AND DUST TEST REPORT

TEMPORARY IMMERSION AND DUST TEST REPORT Report No. :HS1007140060A Version:A TEMPORARY IMMERSION AND DUST TEST REPORT Company :Gold Apollo Co., Ltd Address :3F.-1, No.77, Sec. 1, Xintai 5th Rd., Xizhi City, Taipei County 221, Taiwan (R.O.C.)

More information

and Refrigerant Identifier

and Refrigerant Identifier Contaminated Refrigerant and Refrigerant Identifier What is contaminated refrigerant? Two or many type of refrigerants mixed in the cylinder or Refrigeration and air-conditioning system knowingly or unknowingly

More information

Technical Note. Noise emission from Dehumidifier Type C22/CR100. TC Project no.: T Page 1 of January 2016

Technical Note. Noise emission from Dehumidifier Type C22/CR100. TC Project no.: T Page 1 of January 2016 Technical Note Noise emission from Dehumidifier Type C22/CR100 Performed for COTES A/S TC-100899 Project no.: T211658 Page 1 of 9 15 January 2016 DELTA Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72

More information

Village of Glenview Appearance Commission

Village of Glenview Appearance Commission Village of Glenview Appearance Commission STAFF REPORT January 13, 2016 TO: Chairman and Appearance Commissioners FROM: Community Development Department CASE #: A2016-005 LOCATION: PROJECT NAME: 611 Milwaukee

More information

5 dock doors, 2 grade doors. Sprinklers throughout

5 dock doors, 2 grade doors. Sprinklers throughout VIEW ONLINE collierscanada.com/22011 FOR LEASE: $5.75 PSF NET FOR SALE: $5,400,000 FOR LEASE / SALE 300 Sovereign Road, London ON Excellent Manufacturing Facility with Heavy Power 56,254 SF including 8,000

More information

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement Dräger VARIOx-2 Electronical measuring device for the gas concentration measurement The Dräger VARIOx-2 is used to test and adjust furnaces and auxiliary heating. Optimising combustion to save energy and

More information

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements Test Report issued under the responsibility of: TEST REPORT IEC 60825-1 Safety of laser products - Part 1: Equipment classification and requirements Report Number.... : 102254161MPK-001L Date of issue...

More information

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Ad-hoc IEC 60331-2 x Ad-hoc investigation

More information

Country Report for Tonga

Country Report for Tonga IIEC International Institute for Energy Conservation Country Report for Tonga Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon Islands

More information

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer TEST REPORT IEC 61000-4-2-2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test Report Reference No....: SQE13090002 R/C: 60520

More information

INDEX. Ⅰ. Company Overview. Ⅱ. Business Line. Ⅲ. Business Planning. Ⅳ. Appending - Certificates

INDEX. Ⅰ. Company Overview. Ⅱ. Business Line. Ⅲ. Business Planning. Ⅳ. Appending - Certificates INDEX Ⅰ. Company Overview Ⅱ. Business Line Ⅲ. Business Planning Ⅳ. Appending - Certificates Ⅰ. Company Overview 1. Company Outline Company Name CEO NTREE Co. Ltd. Hong Su Kim Stablished Feb. 2006. 30,

More information

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona Architectural Testing PRODUCT PERFORMANCE TEST REPORT Report No.: D7226.01-121-24 Test Date: May 29, 2014 Rendered to: Natural Light Energy Systems Phoenix, Arizona PRODUCT TYPE: Tubular Daylight Device

More information

Measurement of Safety Integrity of E/E/PES according to IEC61508

Measurement of Safety Integrity of E/E/PES according to IEC61508 Measurement of Safety Integrity of E/E/PES according to IEC61508 Mr. Chen Zhenkang TUV Rheinland Singapore 18. May. 2018 Singapore World Metrology Day 2018 1 Agenda 1. TÜV Rheinland: a Certification Body

More information

Information and Project Plan Proposal for Home Depot Renovation Library

Information and Project Plan Proposal for Home Depot Renovation Library Information and Project Plan Proposal for Home Depot Renovation Library Writing Sample Libby Graham TABLE OF CONTENTS Purpose of the Project... 1 Purpose of the Publications... 2 Usability Goals for the

More information

SUPPLEMENT REPORT No.: XPL/13600/

SUPPLEMENT REPORT No.: XPL/13600/ (Pty) Ltd Certex Appointed Ex Laboratory Reg No: 1999/027771/07 Government Approved Test Laboratory (Previously AIA) T0104 7 Spanner rd, PO Box 467 Tel: +27 (11) 316 4601 Olifantsfontein Fax: +27 (11)

More information

INSPECTION REPORT Nr IDD/S-09/922

INSPECTION REPORT Nr IDD/S-09/922 Page: 1/7 PROJECT: TPI For Sheet Pile BV Client: Manufacturer: Nanjing Grand Steel Piling Co., Ltd. Inspection requested by: Ref: P/o nr: (client to BV) P/o nr: GP09111101 (client to Manufacturer) SUPPLY

More information

Perspective on transition to Air-conditioners with Natural Refrigerants The Godrej Experience

Perspective on transition to Air-conditioners with Natural Refrigerants The Godrej Experience Perspective on transition to Air-conditioners with Natural Refrigerants The Godrej Experience Mr.B.J.Wadia Executive Vice-President (Innovation and Technology) Introduction Who we are Godrej & Boyce Mfg.

More information

This FAQ list is intended to be used only for facilitating the implementation of Regulation (EU) 2015/1095 and Regulation (EU) 2015/1094.

This FAQ list is intended to be used only for facilitating the implementation of Regulation (EU) 2015/1095 and Regulation (EU) 2015/1094. This FAQ list is intended to be used only for facilitating the implementation of Regulation (EU) 2015/1095 and Regulation (EU) 2015/1094. They are not intended to replace the regulations nor to provide

More information

TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS

TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS PROCESS AUTOMATION TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS Recommendations for the Installation and Operation of Light Liquid Separators This White Paper presents European

More information

NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD

NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD ISTMT Test Report For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD Aotom LED Industrial Park, Qingzhuanzhu Road 268, Huanggang, Hubei, China LED Panel Light Model name(s): 22AP3235A (CLC/WLC FPL22-835-32W-130LW-UNV-DIM1-WH)

More information

Country Report for Kiribati

Country Report for Kiribati IIEC International Institute for Energy Conservation Country Report for Kiribati Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon Islands

More information

CapitaLand in joint venture with Mitsubishi Estate for a new residential condominium in Tokyo, Japan

CapitaLand in joint venture with Mitsubishi Estate for a new residential condominium in Tokyo, Japan News Release For Immediate Release 8 August 2012 CapitaLand in joint venture with Mitsubishi Estate for a new residential condominium in Tokyo, Japan Targets launch of new residential development, The

More information

Test report no.: Plug and key - Damp heat test

Test report no.: Plug and key - Damp heat test r Yebotech 14405.docx Test report no.: 14405 Plug and key - Damp heat test EDITION 1 PAGE 1 OF 4 Tel: +27 (0)12 371 2000 Fax: +27 (0)12 371 2001 www.gerotek.co.za WF Nkomo Street Pretoria West P O Box

More information

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor: IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2 Smoke & Toxicity Test WF Report Number: 166040 Date: 13 th August 2007 Test Sponsor: Fiba Tech Industries Ltd. 0249 Page 2 of 13 Bodycote warringtonfire

More information

Refrigerating Appliance DOE Test Report

Refrigerating Appliance DOE Test Report Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Refrigerating Appliance

More information

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL Clipsal and C-Bus are registered trademarks of Clipsal Australia Pty Ltd ABN 27 007 873 529. Copyright Clipsal Australia Pty Ltd 2008. All rights reserved.

More information

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1 REPORT NUMBER: 101145164COQ-005 ORIGINAL ISSUE DATE: April 25, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO udecor Inc.

More information

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit FEATURES 0-30V d.c. measurement range Logging rates between 1s and 12hr Stores readings Connection via two screw terminals USB interface for set-up and data download User-programmable alarm thresholds

More information

Component Description Quantity Storage. Glass Slide 75 mm x 25 mm glass slide C. Storage Case Storage case for the glass slide C

Component Description Quantity Storage. Glass Slide 75 mm x 25 mm glass slide C. Storage Case Storage case for the glass slide C Package Insert QuantiGene View Temperature Validation Kit Cat. No. QV0523 Product Overview The QuantiGene View Temperature Validation Kit uses a National Institute of Standards and Technology (NIST) calibrated

More information

METZIN Bearing Induction Heater. Operating Instructions

METZIN Bearing Induction Heater. Operating Instructions METZIN Bearing Induction Heater Operating Instructions Model: MIH-8.0/ S Specifications and chassis color subject to change without notice. METZIN Technologies & Consulting Pte Ltd. Tel: +65 6898 2957

More information

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD 中国认可国际互认检测 TESTING CNAS L1744 GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD Date Received: Jun 20, 2016 Page 1 of 5 GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD LAIMEI INDUSTRIAL ZONE, CHENGHAI DISTRICT,

More information

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1) JÄ TÜVF=heinland`:.ä;' Preci ely Right. CERTIFICATE of Product Conformity (QAL1) Certificate No.: 0000038506 02 AMs designation: lvlanufacturer: Test Laboratory: Modell 6888Afor02 Rosemount l nc. 8200

More information

BS EN : 2001 & IEC :2000

BS EN : 2001 & IEC :2000 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN 60695-2-11: 2001 & IEC 60695-2-11:2000

More information

Country Report for Niue

Country Report for Niue IIEC International Institute for Energy Conservation Country Report for Niue Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon Islands

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T P R O D U C T D ATA S H E E T www.internationalgasdetectors.com Transmitters Control Systems OLIVER Sensors IGD Accessories TOCSIN 640 Pre-Configured Gas Detection System, CO2, O2 or N2O With all the features

More information

900 ControlEdge Remote Termination Panel (RTP) For Relay Outputs

900 ControlEdge Remote Termination Panel (RTP) For Relay Outputs 900 ControlEdge Remote Termination Panel (RTP) For Relay Outputs Document Number: 51-52-33-135 Effective: September 2017 Supersedes: June 2005 Summary The Remote Termination Panel (RTP) provides an easy

More information

Dräger Pac 5500 Single-Gas Detection Device

Dräger Pac 5500 Single-Gas Detection Device Dräger Pac 5500 Single-Gas Detection Device Longer assignments are its speciality: the single gas instrument, Dräger Pac 5500, has no lifetime limitation, and is ideal for fast and accurate personal monitoring

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic

More information

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529 AS 60529 2004 IEC 60529 Ed 2.1:2001 AS 60529 Australian Standard Degrees of protection provided by enclosures (IP Code) This Australian Standard was prepared by Committee EL-026, Protective Enclosures

More information

Appendix 1 Reference HOB and boiler efficiency

Appendix 1 Reference HOB and boiler efficiency Appendix 1 Reference HOB and boiler efficiency 1. Methods and summary of researches Research on boilers has been conducted to identify reference HOB and set default values of energy efficiency for reference

More information

Powder Extinguisher ABC - composite Portable powder extinguishers

Powder Extinguisher ABC - composite Portable powder extinguishers Powder Extinguisher ABC - composite Portable powder extinguishers The revolution in portable fire extinguishers: composite extinguishers are the latest development in the quest for durable ccorrosion resistant

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev. STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.1 Introduction Honeywell s STT 3000 family of microprocessor based smart

More information

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL BURNING BRAND PERFORMANCE TEST REPORT Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR 022 0000 (Acrylic Dome) VELUX SUN TUNNEL ACCESSORY PRODUCTS: Tubular Skylight with ZTA 022 000090 9" Turrets

More information

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 5720 IR Toxic Gas Detection Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance

More information

NATURAL GAS 1 DAY ANGVA WORKSHOP ON. WORKSHOP 20 May for VEHICLES, YANGON, MYANMAR

NATURAL GAS 1 DAY ANGVA WORKSHOP ON. WORKSHOP 20 May for VEHICLES, YANGON, MYANMAR ANGVA ON for S, YANGON, MYANMAR Natural Gas for Vehicles Overview and Safety Practices for Vehicle Conversions ORGANIZED BY: CERTIFIED BY: global GROUP SPONSORS: MEDIA PARTNER: ABOUT US MESSAGE FROM THE

More information

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006 Report No.:RA-S9504-0992 Reliability Engineering Division Page: 1 of 5 1F, No.22, Pu-ding Rd., Hsin - chu City, Taiwan, R.O.C. http://www.isti.com.tw Company Model Name :A27 DUST TEST REPORT :Gold Apollo

More information

Country Report for Fiji

Country Report for Fiji I I E C International Institute for Energy Conservation Northern Marianas Country Report for Fiji Palau Guam Federated States of Micronesia Marshall Islands Kiribati Papua New Guinea Nauru Solomon Islands

More information

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Page 1 of 157 Report No.: E309264-D1009-1-CB CB - IEC REPORT: Test Report issued under the responsibility of: IEC 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and

More information

SIGMADEK, LTD. FIRE TEST REPORT

SIGMADEK, LTD. FIRE TEST REPORT SIGMADEK, LTD. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON ALUMINUM EXTRUSION DECK BOARD C/W PORCELAIN TILE INSERT REPORT NUMBER H5331.01-121-24 TEST DATE 09/13/17 ISSUE DATE 10/03/17 RECORD RETENTION

More information

MANAGEMENT OF HAZARDOUS WASTE AND E-E WASTE. National Environment Agency Singapore

MANAGEMENT OF HAZARDOUS WASTE AND E-E WASTE. National Environment Agency Singapore MANAGEMENT OF HAZARDOUS WASTE AND E-E WASTE National Environment Agency Singapore Singapore Definition Waste materials which no longer can be used for the purposes they were intended for originally. Hazardous/Toxic

More information

Initial Test Typing Leak test

Initial Test Typing Leak test Inclusa nell albo dei laboratori altamente qualificati, autorizzati dal Ministero dell Università e della Ricerca Scientifica e Tecnologica ex art. 4 legge n. 46/82 (D.M. 25 maggio 1990) Notified Body

More information

Performance Rating of Unit Ventilators

Performance Rating of Unit Ventilators AHRI Standard 840 (I-P) 1 2015 Standard for Performance Rating of Unit Ventilators Price $10.00 (M) $20.00 (NM) Printed in U.S.A. Office Copyright 2009, by Air-Conditioning and Refrigeration Institute

More information

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers: CLM-Series - Solid State Power Controller - Overview CLM-SERIES SOLID STATE POWER CONTROLLER The CLM-Series is a 12 output, solid state power controller. It provides fast switching with low loss solid

More information

NRC REPORTING REQUIREMENTS IN PART 21

NRC REPORTING REQUIREMENTS IN PART 21 NRC REPORTING REQUIREMENTS IN PART 21 Steven P. Frantz Ryan K. Lighty July 28, 2015 2015 Morgan, Lewis & Bockius LLP Background on 10 C.F.R. Part 21 Part 21 implements Section 206 of the Energy Reorganization

More information

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6 Applicant: Y. Lin Electronics Co., Ltd. No. 3 Xinguang Road, Jinhe The third Industrial Zone, Zhangmutou Town, Dongguan,. Guangdong, China. Number: Date: 11 Feb 2015 15020100HKG-001 Sample Description

More information

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers: CLM-Series - Solid State Power Controller - Overview CLM-SERIES SOLID STATE POWER CONTROLLER The CLM-Series is a 12 output, solid state power controller. It provides fast switching with low loss solid

More information

Title 24, Part 6 Certification of Economizer Fault Detection and Diagnostics (FDD)

Title 24, Part 6 Certification of Economizer Fault Detection and Diagnostics (FDD) Title 24, Part 6 Certification of Economizer Fault Detection and Diagnostics (FDD) Title 24, Part 6 Section 120.2(i) requires that economizer FDD functions be installed on air cooled unitary air conditioning

More information

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors The catalytic bead DrägerSensor is designed for the continuous monitoring and detection of combustible gases and vapours with different versions

More information

Test reports for the determination of B 10d values for emergency stop switches of families 800F, 800H, 800T and D7 of Rockwell Automation

Test reports for the determination of B 10d values for emergency stop switches of families 800F, 800H, 800T and D7 of Rockwell Automation Report about the inspection of test reports for the determination of B 10d values for emergency stop switches of families, 800H, 800T and of Rockwell Automation Report-No.: 968/EL 660.01/10 Date: 2010-06-08

More information

Declaration of conformity maintenance record. No Revised date Contents Reasons Approval

Declaration of conformity maintenance record. No Revised date Contents Reasons Approval 1st March 2005 Issue 1 Declaration of conformity maintenance record No Revised date Contents Reasons Approval 1 2 3 4 5 6 7 8 9 10 Security Systems Division Matsushita Electric Industrial Co., Ltd. Yokohama

More information

January 26, Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT Dear Mr. Sunshine:

January 26, Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT Dear Mr. Sunshine: January 26, 2005 Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT 06824 Dear Mr. Sunshine: We appreciate the opportunity to be of service to you. Please find enclosed one bound copy of Intertek

More information

Tuvalu. Tokelau. Samoa. Wallis and Futuna Fiji

Tuvalu. Tokelau. Samoa. Wallis and Futuna Fiji IIEC International Institute for Energy Conservation Country Report for Papua New Guinea Northern Marianas Marshall Islands Guam Palau Federated States of Micronesia Kiribati Papua New Guinea Nauru Solomon

More information

Refrigerating Appliance ErP Test Report

Refrigerating Appliance ErP Test Report Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Date of receipt of sample(s)

More information

BRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters

BRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters /08 2018-01-15 for the Kiwa product certificate for Water meters Preface This evaluation guideline has been accepted by the Kiwa Board of Experts Watercycle (CWK), in which all relevant parties in the

More information

Southern California Gas Company Customer Programs Department

Southern California Gas Company Customer Programs Department Appliance Test Report SCGAT140220A Revision 0 Issued Date: March 2014 Duke 613Q-G1V Gas Convection Oven Performance Test Per ASTM F1496-13 Southern California Gas Company Customer Programs Department Food

More information

CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir

CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir Problem Statement The Iowa DNR plans to monitor a proposed prairie restoration project in eastern Iowa as an experiment.

More information