OFFICIAL. OFFICIAL Page 1 of 10. HALES Evaporator C. Reduction in MOP reservation held on Evaporator C & reallocation to Evaporator A & B

Size: px
Start display at page:

Download "OFFICIAL. OFFICIAL Page 1 of 10. HALES Evaporator C. Reduction in MOP reservation held on Evaporator C & reallocation to Evaporator A & B"

Transcription

1 Title of document HALES Evaporator C Reduction in MOP reservation held on Evaporator C & reallocation to Evaporator A & B Project Assessment Revision 0 15 September 2014 Page 1 of 10

2 Office for Nuclear Regulation, 2014 If you wish to reuse this information visit for details. Published 10/14 For published documents, the electronic copy on the ONR website remains the most current publicly available version and copying or printing renders this document uncontrolled. Office for Nuclear Regulation Page 2 of 10

3 EXECUTIVE SUMMARY This report summarises ONR s review of Sellafield Ltd s proposal to reduce the Magnox Operating Plan (MOP) reservation held on Evaporator C by 50% and to reallocate the duty to Evaporators A & B within the High Level Waste Plants (HLWP) complex. [Background] There are 3 evaporators (A, B & C) within the HLWP complex that concentrate (evaporate) the Highly Active Aqueous Raffinates (HAAR) from reprocessing (Magnox and THORP fuels) and highly active effluents from the waste vitrification process to produce Highly Active Liquor (HAL) prior to conversion to a vitrified waste that is suitable for long term storage. Each of the evaporators is capable of processing Magnox liquors but Evaporator C is the only evaporator capable of handling oxide (THORP) liquors. There are two principal corrosion mechanisms that challenge the integrity of the evaporators heating/cooling components (coils and base) that provide primary containment of the highly active material being processed. The first of these is generalised attack by the process liquors on the outer surface of the coils and inner surface of the vessel, producing a generalised thinning of the steel. The second is waterside pitting corrosion, which occurs on the nonprocess side of the vessel and coils and results in pinhole failure. The operating life, and hence future throughput, of the evaporators will be determined and limited by the progress of corrosion to the heating/cooling components To date Evaporator C, unlike the other two evaporators, has not suffered any pinhole failures of the coils but these have incurred significant thinning due to generalised corrosion; Oxide liquors are significantly more corrosive than Magnox Liquors Some years ago, due to uncertainty regarding the availability of Evaporators A & B to meet the MOP requirements, Sellafield Ltd decided to reserve sufficient capacity, equivalent to that necessary to process all the remaining Magnox fuel, on Evaporator C to ensure completion of the MOP by Any remaining remnant life (capacity) would be used for Oxide fuel processing. When allocating remnant life (projected total future throughput) for evaporator C, priority has always been given to ensuring that sufficient corrosion allowance, i.e. metal thickness, has been given to completion of the MOP as this fuel degrades during pond storage and there is currently no other option available to provide its long-term safe storage. The consequence of this approach is that it limited the amount of oxide fuel that could be processed and Sellafield Ltd currently predict that oxide reprocessing would need to cease by late 2014 to ensure sufficient capacity is reserved on Evaporator C to meet MOP requirements. An improved understanding of the corrosion process has led to the use of an operational regime that is less corrosive and has increased levels of monitoring and oversight. This, together with the return to service of evaporator B, has led Sellafield Ltd to propose a reduction in the MOP reservation held on Evaporator C to that necessary to process 50% (down from 100%) of the outstanding MOP with the remainder being assigned to evaporators A and B. [Assessment and inspection work carried out by ONR in consideration of this request] ONR has reviewed Sellafield Ltd s proposal as articulated within their Plant Modification Proposal (PMP) and associated Justification Paper. ONR considers that Sellafield Ltd s proposal is supportable on the basis that the estimates regarding the corrosion based impact from the Magnox reprocessing are suitably conservative, the measures to monitor usage and Office for Nuclear Regulation Page 3 of 10

4 predict and manage the impact of the ensuing corrosion are adequate and we have appropriate confidence in the continuing availability of sufficient evaporative capacity in evaporators A and B to complete their assigned Magnox duty. Furthermore, Sellafield Ltd s operating philosophy for Evaporator C continues to ensure MOP processing receives appropriate priority [Conclusions] It is ONR s opinion that Sellafield Ltd s proposal to reduce the corrosion allowance on Evaporator C coils down from that equivalent to the whole of the remaining MOP to that equivalent to half the MOP is underpinned by appropriate conservatisms associated with the MOP processing capabilities (remnant life) of evaporators A and B and that Sellafield Ltd have appropriate management controls in place to monitor evaporative capacity and take appropriate action to ensure completion of the MOP by 2020 is not compromised. The MOP corrosion allowance on Evaporator C released under this proposal would be used to support continued oxide reprocessing. [Recommendation] ONR confirms that it has no objections to Sellafield Ltd s proposal to reduce the corrosion allowance on the Evaporator C coils from that equivalent to 100% of the outstanding MOP down to 50% and reallocate the duty to Evaporators A & B. Office for Nuclear Regulation Page 4 of 10

5 LIST OF ABBREVIATIONS HAAR HAL HALES HLWP MOP MSC ONR PAR PMP WVP Highly Active Aqueous Raffinate Highly Active Liquor Highly Active Liquor Evaporation and Storage High Level Waste Plants Magnox Operating Plan Management Safety Committee Office for Nuclear Regulation Project Assessment Report Plant Modification Proposal Waste Vitrification Plant Office for Nuclear Regulation Page 5 of 10

6 TABLE OF CONTENTS 1 PERMISSION REQUESTED BACKGROUND ASSESSMENT AND INSPECTION WORK CARRIED OUT BY ONR IN CONSIDERATION OF THIS REQUEST CONCLUSIONS RECOMMENDATIONS REFERENCES Office for Nuclear Regulation Page 6 of 10

7 1 PERMISSION REQUESTED 1. This report summarises ONR s review of Sellafield Ltd s proposal (Ref 1) to reduce the Magnox Operating Plan (MOP) reservation held on Evaporator C by 50% and reallocate the duty to Evaporators A & B. ONR chose to make a regulatory judgement on the adequacy of Sellafield Ltd s proposal, given the importance of evaporator capacity in supporting hazard and risk reduction from spent fuel reprocessing activities at the Sellafield site. 2. Sellafield Ltd s proposal modifies assumptions made under a previous Plant Modification Proposal (PMP) (Ref 2) and Licence Instrument (LI 836) (Ref 3), which required sufficient remnant life to be reserved on Evaporator C to support magnox liquor arisings to ensure completion of the MOP by This report covers Sellafield Ltd s proposal to change the management of the MOP reservation from Evaporator C to across the evaporator fleet. 2 BACKGROUND 3. Highly Active Aqueous Raffinates (HAAR) are generated from reprocessing activities (Magnox & THORP) on the Sellafield site. The raffinates go through an evaporation process within the High Level Waste Plants (HLWP s) to produce Highly Active Liquor (HAL) that is stored in Highly Active Storage Tanks (HASTs), prior to conversion into a vitrified glass waste within the Waste Vitrification Plant (WVP) that is suitable for longterm storage. The evaporators within the Highly Active Liquor Evaporation and Storage (HALES) facility therefore form a fundamental part in supporting hazard and risk reduction from spent fuel reprocessing activities at the Sellafield site. 4. There are three evaporators (A,B & C) within the HLWP s that concentrate the raffinates from Magnox reprocessing and highly active effluents from the waste vitrification process. Evaporator C is the only evaporator capable of handling THORP (Oxide) as well as Magnox liquors. 5. All of the evaporators have incurred significant corrosion attack and there are two principal corrosion mechanisms that challenge the integrity of the evaporators. The first of these is generalised attack by the process liquors on the outer surface of the coils and inner surface of the vessel, producing a generalised thinning of the steel. The second is waterside pitting corrosion, which occurs on the non-process side of the vessel and coils and results in pinhole failure. 6. It is widely recognised that the operating life, and hence throughput of the evaporators will be determined and limited by the progress of corrosion to the heating / cooling components (coils and base), which provide primary containment for highly active material being processed. Sellafield Ltd therefore monitor the progress of corrosion on the evaporators to assure themselves that there is sufficient metal remaining within the coils and the base of the vessel to ensure end of life safety case limits and hence integrity of the evaporators is not breached. 7. To date Evaporator C has not suffered any pinhole failures but is subject to significant generalised corrosion as Oxide liquors are more corrosive than Magnox Liquors. However, Evaporators A & B have suffered a number of pin-hole failures on their coils in the mid 2000 s as a result of waterside pitting. Due to concerns regarding the availability of Evaporators A & B to process Magnox (as a result of a number of pin hole failures on the coils) Sellafield Ltd decided to reserve sufficient capacity on Evaporator C to ensure completion of the MOP. When allocating remnant life (projected total future throughput) for evaporator C, priority has always been given to ensuring that sufficient corrosion allowance, i.e. metal thickness, has been given to Office for Nuclear Regulation Page 7 of 10

8 completion of the MOP as this fuel degrades during pond storage and there is currently no other option available to provide its long-term safe storage. The consequence of this approach is that it limited the amount of oxide fuel that could be processed. 8. Sellafield Ltd currently predict that oxide reprocessing would need to cease 2014/2015 (Ref 1) to ensure sufficient capacity is reserved on Evaporator C to complete the MOP. Sellafield Ltd claim that there are strong drivers to maximise oxide reprocessing as they consider: the storage of vitrified product containers is safer than the long term storage of irradiated fuel there is some irradiated oxide fuel that is not compatible with long term storage in the fuel pond so needs to be reprocessed so it does not create a long term nuclear legacy issue. space will be created within the oxide fuel ponds, which can be used to support an extension to the Advanced Gas Reactor station life, thereby safeguarding power generation 9. An improved understanding of the corrosion process has led to the use of an operational regime that is less corrosive and has increased levels of monitoring and oversight. This, together with the return to service of evaporator B, has led Sellafield Ltd to propose a reduction in the MOP reservation held on Evaporator C to that necessary to process 50% (down from 100%) of the outstanding MOP with the remainder being assigned to evaporators A and B. This PAR supports ONR s regulatory judgement on the adequacy of Sellafield Ltd s proposal to manage the MOP reservation across the evaporator fleet. The MOP corrosion allowance on Evaporator C released under this proposal would be used to support continued oxide reprocessing. 3 ASSESSMENT AND INSPECTION WORK CARRIED OUT BY ONR IN CONSIDERATION OF THIS REQUEST 10. ONR has carried out a review of Sellafield Ltd s proposal, as articulated within the PMP (Ref 1) and the associated justification paper (Ref 4). Both these documents have been endorsed by the HALES Management Safety Committee (MSC). 11. Although Evaporators A & B have been subject to a number of pinhole failures on their coils, Sellafield Ltd estimate that Evaporators A & B currently have the capacity to support completion of the MOP. Sellafield Ltd claim that since 2009 the availability of Evaporator A has been high and has demonstrated that it is capable of supporting 67% of the daily MOP arisings on jacket only, leaving the remaining 33% to be processed via Evaporator B and/or Evaporator C. In addition, Sellafield estimate Evaporator B will be capable of supporting 100% of the MOP arising on jacket and its one remaining operational coil and 67% of arisings on base only (if last remaining coil fails). This would leave the remaining 33% of the MOP to be processed via Evaporator A and/or Evaporator C. 12. ONR requested Sellafield Ltd to consider the extended unavailability of both Evaporators A & B and the impact this may have on the completion of the MOP by Sellafield Ltd have confirmed (Ref 1) that in such an event, a review of operating arrangements would be undertaken and necessary decisions made to ensure that sufficient capacity remains across the evaporator fleet to meet the MOP requirements. In addition, Sellafield Ltd will be monitoring evaporative capacity on a quarterly basis to assure themselves in the ability of the entire fleet to meet the MOP requirements. ONR is content with this approach, which aligns with the requirements agreed under LI 836. Office for Nuclear Regulation Page 8 of 10

9 13. The reallocation of 50% of the MOP reservation held on Evaporator C will support approximately 12 months of oxide processing. However, ONR notes that Sellafield Ltd have initiated a number of programmes of work (Ref 1) aimed to extend the remnant life of Evaporator C to meet the remaining oxide capacity gap until Evaporator D becomes available in ONR considers that Sellafield Ltd have a good understanding of the corrosion mechanisms that are prevalent in the evaporators, which has led to the use of an operational regime that is less corrosive and has increased levels of monitoring and oversight. ONR also considers Sellafield Ltd have appropriate arrangements (as agreed under LI 836) in place to control, monitor and report the impact of ongoing processing (corrosion) to ensure the integrity of the evaporators and completion of the MOP by 2020 is not compromised. Furthermore, ONR considers that the proposal is underpinned by appropriate conservatisms associated with MOP processing capabilities (remnant life) and we have appropriate confidence in the continuing availability of sufficient evaporative capacity to meet the MOP. The availability of Evaporator D in 2017 provides further confidence to ensure MOP requirements will be met. 15. Overall, ONR considers that Sellafield Ltd s proposal for the 50% reduction in MOP reservation held on Evaporator C is supportable on the basis that it continues to ensure that processing of the MOP receives appropriate operational priority. The MOP corrosion allowance on Evaporator C released under this proposal would be used to support continued oxide reprocessing. 4 CONCLUSIONS 16. This report presents the findings of ONR s regulatory judgement on the adequacy of Sellafield Ltd s proposal to reduce the MOP reservation held on Evaporator C by 50%. In summary ONR is content that: Sellafield Ltd s proposal (PMP (Ref 1)) and the associated justification paper (Ref 4) for the reduction of MOP reservation held on Evaporator C has been endorsed by the HALES MSC thus giving increased regulatory confidence. The proposal is underpinned by appropriate conservatisms to ensure the reallocation of 50% of the MOP is unlikely to present an unacceptable challenge to the completion of the MOP by Sellafield Ltd have appropriate management controls in place to monitor the evaporative capacity and take appropriate action to ensure completion of the MOP by 2020 is not compromised. The proposal continues to ensure that the MOP receives appropriate operational priority, with any remaining remnant life being managed to support continued oxide reprocessing. 17. To conclude, ONR is broadly satisfied that Sellafield Ltd have made an adequate case justifying the management of the MOP reservation across the evaporator fleet, which will enable further oxide fuel raffinates to be processed. 5 RECOMMENDATIONS 18. ONR confirms that it has no objections to Sellafield Ltd s proposal to reduce the corrosion allowance on Evaporator C coils from that equivalent to 100% of the outstanding MOP down to 50% and reallocate the duty to Evaporators A & B. Office for Nuclear Regulation Page 9 of 10

10 6 REFERENCES 1. Plant Modification Proposal. Reduction in MOP reservation on Evaporator C and reallocatin to Evaporators A and B - HALES/B***/1291, 9th July TRIM 2014/ Plant Modification Proposal. Implementation of revised managerial controls to monitor and report Evaporator C heating/cooling component usage within current safety case limits - PMP HALES/B***/1099, April TRIM 2012/ Licence Instrument 836. Agreement to Commence Modification to an Existing Plant Implementation of Revised Managerial Controls to Monitor and Report Evaporator C Heating/Cooling Component Usage, Within Current Safety Case Limits (PMP HALES/B***/1099), July TRIM 2012/ Sellafield Ltd. Justification for the partial re-allocation of MOP reservation from Evaporator C to Evaporators A & B - HALES MSC P(14)039, 19th June TRIM 2014/ Office for Nuclear Regulation Page 10 of 10

Oxford Green Belt Study. Summary of Final Report Prepared by LUC October 2015

Oxford Green Belt Study. Summary of Final Report Prepared by LUC October 2015 Oxford Green Belt Study Summary of Final Report Prepared by LUC October 2015 Project Title: Oxford Green Belt Study Client: Oxfordshire County Council Version Date Version Details Prepared by Checked by

More information

Value Paper Authors: Stuart Nunns CEng, BSc, FIET, FInstMC. Compliance to IEC means more than just Pfd!

Value Paper Authors: Stuart Nunns CEng, BSc, FIET, FInstMC. Compliance to IEC means more than just Pfd! Value Paper Authors: Stuart Nunns CEng, BSc, FIET, FInstMC Compliance to IEC 61508 means more than just Pfd! Compliance to IEC 61508 means more than just Pfd! Market environment Statistics relating to

More information

Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry

Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry 1. Introduction Author: Colin Easton ProSalus Limited ~ Independent Safety Consultants Within the United

More information

Cookham Parish Council s Response to The Draft Local Borough Plan

Cookham Parish Council s Response to The Draft Local Borough Plan Cookham Parish Council s Response to The Draft Local Borough Plan As Agreed at the Planning Committee Meeting on 10 th January 2017. Designation of Poundfield as a Local Green Space The Parish Council

More information

PRIMATECH WHITE PAPER CHANGES IN THE SECOND EDITION OF IEC 61511: A PROCESS SAFETY PERSPECTIVE

PRIMATECH WHITE PAPER CHANGES IN THE SECOND EDITION OF IEC 61511: A PROCESS SAFETY PERSPECTIVE PRIMATECH WHITE PAPER CHANGES IN THE SECOND EDITION OF IEC 61511: A PROCESS SAFETY PERSPECTIVE Summary From the perspective of process safety, the most notable change is the addition of requirements for

More information

Secretary of State determination under article 36 of the Fire Safety Order

Secretary of State determination under article 36 of the Fire Safety Order Fire and Rescue Service Circular Circular number 48/2009 Date issued 13 August 2009 This circular is For information and consideration Status This circular covers the outcome of a referral to the Secretary

More information

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd Abstract Session Four Functional safety: the next edition of IEC 61511 Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd The functional safety standard IEC 61511 provides a framework for managing

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61511-1 First edition 2003-01 Functional safety Safety instrumented systems for the process industry sector Part 1: Framework, definitions, system, hardware and software requirements

More information

Perth and Kinross Council Development Management Committee 20 February 2013 Report of Handling by Development Quality Manager

Perth and Kinross Council Development Management Committee 20 February 2013 Report of Handling by Development Quality Manager Perth and Kinross Council Development Management Committee 20 February 2013 Report of Handling by Development Quality Manager 4(4)(iii) 13/81 Erection of sports hall, associated changing facilities, offices

More information

EFDC Draft Local Plan Consultation Theydon Bois Guidance Notes Extended Version

EFDC Draft Local Plan Consultation Theydon Bois Guidance Notes Extended Version EFDC Draft Local Plan Consultation Theydon Bois Guidance Notes Extended Version There are nine questions you can respond to in the consultation if you wish. Epping Forest District Council (EFDC) has a

More information

References: Patent Law (Article 2(3), Article 68, and Article 100) Reasons

References: Patent Law (Article 2(3), Article 68, and Article 100) Reasons Case number 2005 (Ne) 10021 Party [Appellant-Plaintiff] Canon Inc. [Appellee-Defendant] Recycle Assist Co., Ltd. Decided on January 31, 2006 Division Grand Panel Holdings: This is a case in which patent

More information

Functional Safety: the Next Edition of IEC 61511

Functional Safety: the Next Edition of IEC 61511 HazAus2015/1507 Functional Safety: the Next Edition of IEC 61511 Mirek Generowicz Engineering Manager I&E Systems Pty Ltd Level 2, 445 Hay Street Perth WA 6000 Abstract The functional safety standard IEC

More information

PLANNING COMMITTEE REPORT

PLANNING COMMITTEE REPORT PLANNING COMMITTEE REPORT TO: BY: Planning Committee South Head of Development DATE: 19 December 2017 DEVELOPMENT: SITE: WARD: APPLICATION: APPLICANT: Conversion of existing water storage reservoir to

More information

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE Revision D January 14, 2005 DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE I. INTRODUCTION The Commission s requirements for fire protection of nuclear power plants allow licensees to voluntarily

More information

Y. ORMIERES. Fire risk analysis method for nuclear installations

Y. ORMIERES. Fire risk analysis method for nuclear installations Y. ORMIERES Fire risk analysis method for nuclear installations 2 Fire risk analysis method for nuclear installations A position on the management of fire safety analysis in nuclear installations by specifying:

More information

BUSINESS PLAN CEN/TC 72 FIRE DETECTION AND FIRE ALARM SYSTEMS EXECUTIVE SUMMARY

BUSINESS PLAN CEN/TC 72 FIRE DETECTION AND FIRE ALARM SYSTEMS EXECUTIVE SUMMARY BUSINESS PLAN CEN/TC 72 FIRE DETECTION AND FIRE ALARM SYSTEMS CEN/TC 72 Business Plan Page: 1 EXECUTIVE SUMMARY Scope To prepare standards, harmonised where necessary, to meet the essential requirements

More information

New requirements for IEC best practice compliance

New requirements for IEC best practice compliance New requirements for IEC 61511 best practice compliance Proof testing and a SIL study may no longer be enough by Sven Grone Schneider Electric Safety Services Practice Leader Executive summary Since its

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61511-2 First edition 2003-07 Functional safety Safety instrumented systems for the process industry sector Part 2: Guidelines for the application of IEC 61511-1 Reference number

More information

BUSINESS PLAN CEN/TC 208 ELASTOMERIC SEALS FOR JOINTS IN PIPEWORK AND PIPELINES EXECUTIVE SUMMARY

BUSINESS PLAN CEN/TC 208 ELASTOMERIC SEALS FOR JOINTS IN PIPEWORK AND PIPELINES EXECUTIVE SUMMARY Page: 1 Business environment BUSINESS PLAN CEN/TC 208 ELASTOMERIC SEALS FOR JOINTS IN PIPEWORK AND PIPELINES EXECUTIVE SUMMARY The 5 standards published by CEN/TC 208 since 1996 are used throughout the

More information

Extension of Registered Gas Installer Scheme to include Non-Domestic Gas Works

Extension of Registered Gas Installer Scheme to include Non-Domestic Gas Works Extension of Registered Gas Installer Scheme to include Non-Domestic Gas Works Information Paper Reference: CER/16373 Date Published: 15/12/2016 Closing Date: NA Executive Summary The CER has decided to

More information

GUILDFORD BOROUGH GREEN BELT AND COUNTRYSIDE STUDY

GUILDFORD BOROUGH GREEN BELT AND COUNTRYSIDE STUDY GUILDFORD BOROUGH GREEN BELT AND COUNTRYSIDE STUDY Volume II - Addendum On behalf of Guildford Borough Council PPG Ref : BNL.0287 April 2014 COPYRIGHT The conents of this document must not be copied or

More information

BUSINESS PLAN CEN/TC 250 STRUCTURAL EUROCODES EXECUTIVE SUMMARY

BUSINESS PLAN CEN/TC 250 STRUCTURAL EUROCODES EXECUTIVE SUMMARY Page: 1 BUSINESS PLAN CEN/TC 250 STRUCTURAL EUROCODES EXECUTIVE SUMMARY Scope CEN/TC 250 covers the standardization of structural and geotechnical design rules for building and civil engineering works

More information

Chief Operating Officer Giampiero Belcredi

Chief Operating Officer Giampiero Belcredi CONTENTS 1. PURPOSE AND SCOPE 2. GENERAL PRINCIPLES AND GUARANTEES FOR THE CLIENT 3. ACCESS REQUIREMENTS FOR CERTIFICATION 4. ASSESSMENT PROCESS REQUIREMENTS 5. SUSPENSION AND REVOCATION OF THE CERTIFICATION

More information

GK/GN0612. Guidance on Signalling Lockout Systems to Protect Railway. Undertaking Personnel. Railway Group Guidance for GK/RT0212.

GK/GN0612. Guidance on Signalling Lockout Systems to Protect Railway. Undertaking Personnel. Railway Group Guidance for GK/RT0212. GN Published by Rail Safety and Standards Board Evergreen House 160 Euston Road London NW1 2DX Copyright 2007 Rail Safety and Standards Board Limited GK/GN0612 Issue One: August 2007 Railway Group Guidance

More information

IAEA SAFETY STANDARDS

IAEA SAFETY STANDARDS SAFETY STANDARDS FOR DESIGN AND SAFETY ASSESSMENT Oct 2011 Peter Hughes Head of Safety Assessment Section Division of Nuclear Installation Safety International Atomic Energy Agency Contents Safety Standards

More information

Supply and installation of a gas delivery unit for Hydrogen fluoride (HF) and a vertical furnace

Supply and installation of a gas delivery unit for Hydrogen fluoride (HF) and a vertical furnace ANNEX I EUROPEAN COMMISSION JOINT RESEARCH CENTRE Institute for Transuranium Elements (Karlsruhe) Karlsruhe, 18.03.2009 European Commission Institute for Transuranium Elements im Forschungszentrum Karlsruhe

More information

CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT

CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT These Conditions of Service apply to all NBN Services. These Conditions of Service form part of our Standard Form of Agreement found at www.adam.com.au/legal.

More information

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update Technical Paper Functional Safety Update IEC 61511 Edition 2 Standards Update Functional Safety Update Table of Contents 1.0 Introduction 2.0 IEC 61511-1 changes 3.0 IEC 61511-2 changes 4.0 IEC 61511-3

More information

Draft Hailey Neighbourhood Plan

Draft Hailey Neighbourhood Plan Persimmon Homes (Wessex) Draft Hailey Neighbourhood Plan Representations to West Oxfordshire District Council s Regulation 16 Consultation December 2018 2 Copyright 2018 Persimmon Homes Ltd. All rights

More information

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

Australian Standard. Functional safety Safety instrumented systems for the process industry sector AS IEC 61511.2 2004 IEC 61511-2:2003 AS IEC 61511.2 Australian Standard Functional safety Safety instrumented systems for the process industry sector Part 2: Guidelines for the application of AS IEC 61511.1

More information

University of Bristol - Explore Bristol Research. Peer reviewed version. Link to publication record in Explore Bristol Research PDF-document

University of Bristol - Explore Bristol Research. Peer reviewed version. Link to publication record in Explore Bristol Research PDF-document Hutson, C., Payne, L., Scott, T., & Jenkins, A. (2017). Deployment of Diamond-Based Radiation Detector for Very High Dose Rate Measurements. In Waste Management Symposia 2017: Proceedings of a meeting

More information

26 June 2001 GUIDELINES ON ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY

26 June 2001 GUIDELINES ON ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 Telex: 23588 IMOLDN G IMO E Ref. T4/4.01 MSC/Circ.1002 26 June 2001 GUIDELINES ON ALTERNATIVE

More information

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems Building Standards Division Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems Crown Copyright 2015 Produced by the Buildings Standards Division February 2015 Version

More information

Branch Fire Rescue Services

Branch Fire Rescue Services Branch Fire Rescue Services Introduction Through the protection of life, property and the environment, Fire Rescue Services strives to improve the livability of all Edmontonians. The provision of internationally-recognized

More information

Emergency. Management. Emergency. Readiness Checklist

Emergency. Management. Emergency. Readiness Checklist Management Readiness Checklist Introduction Enclosed is your complimentary Readiness Checklist. This best-practice checklist will enable you to assess how well prepared you are for an emergency. It is

More information

Perth and Kinross Council Development Management Committee 24 April 2013 Report of Handling by Development Quality Manager

Perth and Kinross Council Development Management Committee 24 April 2013 Report of Handling by Development Quality Manager Perth and Kinross Council Development Management Committee 24 April 2013 Report of Handling by Development Quality Manager Alterations,Carpenter House, Carpenter Street, Perth, PH1 5GB Ref. No: 13/00303/FLL

More information

Fire Safety Policy and Procedures

Fire Safety Policy and Procedures Approved by: Date of approval: September 2015 Originator: Helen Garfield, Chief Executive Officer Policy Statement The safety of staff, patients, volunteers and visitors in the event of fire is an issue

More information

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31. Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Air Leakage Performance of

More information

NUCLEAR REGULATORY COMMISSION. [Docket No ; NRC ] Exemption Requests for Special Nuclear Material License SNM-362,

NUCLEAR REGULATORY COMMISSION. [Docket No ; NRC ] Exemption Requests for Special Nuclear Material License SNM-362, This document is scheduled to be published in the Federal Register on 04/13/2012 and available online at http://federalregister.gov/a/2012-08917, and on FDsys.gov [7590-01-P] NUCLEAR REGULATORY COMMISSION

More information

Dangerous Assumptions

Dangerous Assumptions Dangerous Assumptions In light of the lessons learned from the Lakanal House fire, the on-going competent inspection of passive fire protection is crucial to safeguarding those who put their trust in social

More information

NOTTINGHAM CITY HOMES

NOTTINGHAM CITY HOMES APPENDIX 1 NOTTINGHAM CITY HOMES FIRE SAFETY POLICY 2013/14 Draft for Board Uncontrolled when printed Page 1 of 14 DOCUMENT CONTROL Identification and Approval Status Document Title: Nottingham City Homes

More information

Single Market : regulatory environment, standardisation and New Approach Pressure equipment, medical devices, metrology M/327

Single Market : regulatory environment, standardisation and New Approach Pressure equipment, medical devices, metrology M/327 EUROPEAN COMMISSION ENTERPRISE DIRECTORATE-GENERAL Single Market : regulatory environment, standardisation and New Approach Pressure equipment, medical devices, metrology Committee on Standards and Technical

More information

Appendix A: Retail Planning Assessment

Appendix A: Retail Planning Assessment Rotherham Town Centre Masterplan Appendix A: Retail Planning Assessment 139 Appendix A Rotherham Town Centre Masterplan Retail Planning Background and Policy Context 1. Introduction 1.1 The Masterplan

More information

SIL DETERMINATION AND PROBLEMS WITH THE APPLICATION OF LOPA

SIL DETERMINATION AND PROBLEMS WITH THE APPLICATION OF LOPA SIL DETERMINATION AND PROBLEMS WITH THE APPLICATION OF LOPA Alan G King Hazard & Reliability Specialist, ABB Engineering Services, Billingham, Cleveland UK. TS23 4YS For a number of years, industry has

More information

COMPETENCE. Lead Fire Warden. Standard Title Lead Fire Warden Competence Assessment Standard Lead Fire Warden Competence Assessment Standard

COMPETENCE. Lead Fire Warden. Standard Title Lead Fire Warden Competence Assessment Standard Lead Fire Warden Competence Assessment Standard Lead Fire Warden COMPETENCE CRO EMERGENCY RESPONSE COMPETENCE ASSESMENT Standard Title Code Lead Fire Warden Competence Assessment Standard 4502 Revision 0 (28th October 2016) Page 1 of 29 OPITO STANDARDS

More information

Former Evans Halshaw Garage, East Bay Close, Cardiff.

Former Evans Halshaw Garage, East Bay Close, Cardiff. Former Evans Halshaw Garage, East Bay Close, Cardiff. Planning Statement Proposed Redevelopment to Provide Student Accommodation. On behalf of JEDS Investments Revised April 2018 CONTENTS 1.0 INTRODUCTION---------------------------------------------------------------------------Page

More information

Branch Fire Rescue Services

Branch Fire Rescue Services Introduction Fire Rescue Services serves to protect the lives, properties and environment of citizens within our community by providing excellence in services and public safety. Edmonton Fire Rescue Services

More information

ROCHFORD LOCAL DEVELOPMENT FRAMEWORK: Sustainability Appraisal/ Strategic Environmental Assessment. Rochford Core Strategy Preferred Options Document

ROCHFORD LOCAL DEVELOPMENT FRAMEWORK: Sustainability Appraisal/ Strategic Environmental Assessment. Rochford Core Strategy Preferred Options Document ROCHFORD LOCAL DEVELOPMENT FRAMEWORK: Sustainability Appraisal/ Strategic Environmental Assessment Non Technical Summary Rochford Core Strategy Preferred Options Document October 2008 SUSTAINABILITY APPRAISAL

More information

DSO Compliance Report 2009

DSO Compliance Report 2009 DSO Compliance Report 2009 ESB Networks Ltd 31 st March 2010 Introduction ESB Networks Ltd was vested as Distribution System Operator (DSO) on 1 st January 2009 in accordance with the European Communities

More information

Dan Gray, Property Director. Date: November 2017 Review Due Date: November 2020

Dan Gray, Property Director. Date: November 2017 Review Due Date: November 2020 Policy title: Scope: Policy owner & job title: Approver: Fire Safety Policy Group-wide Dan Gray, Property Director Aspire Housing Board Date: November 2017 Review Due Date: November 2020 POLICY SUMMARY

More information

LEEDS SITE ALLOCATIONS PLAN MATTER 3 GREEN BELT KCS DEVELOPMENT AUGUST 2017

LEEDS SITE ALLOCATIONS PLAN MATTER 3 GREEN BELT KCS DEVELOPMENT AUGUST 2017 LEEDS SITE ALLOCATIONS PLAN MATTER 3 GREEN BELT KCS DEVELOPMENT AUGUST 2017 Smith Limited Suite 9C Joseph s Well Hanover Walk Leeds LS3 1AB T: 0113 2431919 F: 0113 2422198 E: planning@peacockandsmith.co.uk

More information

Fire Sprinklers Working Group Final Report

Fire Sprinklers Working Group Final Report Introduction The Building Act received Royal Assent on March 25, 2015. The Act aims to establish more consistent building requirements across British Columbia and create a more robust and modern building

More information

Interim Advice Note 76 / 06 ASSESSMENT PART 1 AIMS AND OBJECTIVES OF ENVIRONMENTAL ASSESSMENT. Contents

Interim Advice Note 76 / 06 ASSESSMENT PART 1 AIMS AND OBJECTIVES OF ENVIRONMENTAL ASSESSMENT. Contents Interim Advice Note 76 / 06 VOLUME 11 SECTION 1: ENVIRONMENTAL ASSESSMENT INTRODUCTION PART 1 AIMS AND OBJECTIVES OF ENVIRONMENTAL ASSESSMENT Contents 1. Introduction and Application 2. Aims and Objectives

More information

CHRISTOPHER WICKHAM ASSOCIATES Town Planning Consultancy

CHRISTOPHER WICKHAM ASSOCIATES Town Planning Consultancy ROCHFORD CORE STRATEGY EXAMINATION STATEMENT BY CHRISTOPHER WICKHAM ASSOCIATES (4961) ON BEHALF OF INNER LONDON GROUP (9917) POLICY H1 THE EFFICIENT USE OF LAND FOR HOUSING REPRESENTATION ID: 16190 CHRISTOPHER

More information

Fire Risks of Loviisa NPP During Shutdown States

Fire Risks of Loviisa NPP During Shutdown States Fire Risks of Loviisa NPP During Shutdown States Sami Sirén a*, Ilkka Paavola a, Kalle Jänkälä a a Fortum Power And Heat Oy, Espoo, Finland Abstract: Fire PRA for all 15 shutdown states of Loviisa NPP

More information

FTTN Business Readiness Testing Special Terms

FTTN Business Readiness Testing Special Terms NBN Co Limited [Customer] FTTN Business Readiness Testing Special Terms This document is a Standard Form of Access Agreement for the purposes of Part XIC of the Competition and Consumer Act 2010. NBN Co

More information

FIRE SAFETY POLICY Revised March 2013

FIRE SAFETY POLICY Revised March 2013 FIRE SAFETY POLICY Revised March 2013 CONTENTS Page No 1.0 Statement of Intent 1 2.0 Fire Safety Accountability Structure 2 3.0 Roles and Responsibilities 3 4.0 Fire Safety Management 7 5.0 Fire Risk Assessment

More information

A global view of integrated closure and legacy planning

A global view of integrated closure and legacy planning 18 September 2013 A global view of integrated closure and legacy planning Mine Closure 2013, Eden Project, Cornwall Dr. William Adams General manager, Legacy and Closure A changing business climate The

More information

About 10% of the Borough's population lives in the seven rural parishes. Population figures from the 1991 census are given below:-

About 10% of the Borough's population lives in the seven rural parishes. Population figures from the 1991 census are given below:- 8. THE DISTRICT VILLAGES 8.1 Population About 10% of the Borough's population lives in the seven rural parishes. Population figures from the 1991 census are given below:- Village No. of Persons Cottingham

More information

UNDERSTANDING ELECTRICAL SAFETY RISKS

UNDERSTANDING ELECTRICAL SAFETY RISKS UNDERSTANDING ELECTRICAL SAFETY RISKS The Electrical Safety Program at BC Safety Authority (BCSA) is responsible for overseeing the safety of electrical systems across British Columbia in accordance with

More information

SAFETY EVALUATION REPORT FOR THE TANK FARMS FIRE HAZARDS ANALYSIS

SAFETY EVALUATION REPORT FOR THE TANK FARMS FIRE HAZARDS ANALYSIS ATTACHMENT 02 OSO 004 SAFETY EVALUATION REPORT FOR THE TANK FARMS FIRE HAZARDS ANALYSIS OCTOBER 2002 Approved by Chris J. Bosted, Director Operations and Safety Oversight Division Date Dana Bryson, Director

More information

FIRE SAFETY POLICY. Date approved: 28 September 2018 Approved by:

FIRE SAFETY POLICY. Date approved: 28 September 2018 Approved by: FIRE SAFETY POLICY FIRE SAFETY POLICY Date approved: 28 September 2018 Approved by: SMT Responsible Manager (s): Health and Safety Manager Executive Lead: Chief Operating Officer Applicable to staff: Applicable

More information

INTRODUCTION NORTH HEYBRIDGE GARDEN SUBURB

INTRODUCTION NORTH HEYBRIDGE GARDEN SUBURB INTRODUCTION This event is being hosted by the promoters of the proposed North Heybridge Garden Suburb who are working with Maldon District Council and other key stakeholders on the preparation of a comprehensive

More information

Instrumentation for Nuclear Applications

Instrumentation for Nuclear Applications Instrumentation for Nuclear Applications Nuclear Instrumentation Overview Delta Controls has been designing and manufacturing instrumentation for the power and process industries for over 65 years and

More information

Qualification Specification Highfield Level 1 Award in the Principles of Fire Safety Awareness (RQF)

Qualification Specification Highfield Level 1 Award in the Principles of Fire Safety Awareness (RQF) Qualification Specification Highfield Level 1 Award in the Principles of Fire Safety Awareness (RQF) Qualification Number: 603/1564/7 Version 1.1 July 2017 Copyright 2017 HABC Ltd. All rights reserved

More information

Awarding body monitoring report for: Institute of Legal Executives (ILEX) February 2008 QCA/08/3734

Awarding body monitoring report for: Institute of Legal Executives (ILEX) February 2008 QCA/08/3734 Awarding body monitoring report for: Institute of Legal Executives (ILEX) February 2008 QCA/08/3734 2008 Qualifications and Curriculum Authority 2 Contents Introduction...4 Regulating external qualifications...4

More information

Wayside horn noise investigation

Wayside horn noise investigation Wayside horn noise investigation Simon Moore AECOM, Level 28, 91 King William Road, Adelaide, Australia ABSTRACT Warning horns are used by trains and sounded when approaching a level to warn of its presence.

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 3760:2003 (Incorporating Amendment No. 1) AS/NZS 3760:2003 Australian/New Zealand Standard In-service safety inspection and testing of electrical equipment AS/NZS 3760:2003 This Joint Australian/New

More information

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard AS/NZS 3500.4:2015 Incorporating Amendment No. 1 Australian/New Zealand Standard Plumbing and drainage Part 4: Heated water services Superseding AS/NZS 3500.4:2003 AS/NZS 3500.4:2015 AS/NZS 3500.4:2015

More information

Independent Study Shows Sludge Build-up Significantly Affects Hydronic Heating System Performance

Independent Study Shows Sludge Build-up Significantly Affects Hydronic Heating System Performance Independent Study Shows Sludge Build-up Significantly Affects Hydronic Heating System Performance The Benefits of Proper Cleaning & Flushing Introduction There is considerable evidence that many installers

More information

High Speed Rail (London- West Midlands)

High Speed Rail (London- West Midlands) High Speed Rail (London- West Midlands) Draft Environmental Minimum Requirements Annex 3: Draft Heritage Memorandum November 2013 ESA 4.4 High Speed Rail (London- West Midlands) Draft Environmental Minimum

More information

Glenborough at Easton Land Use Master Plan

Glenborough at Easton Land Use Master Plan Implementation 114 9.0 IMPLEMENTATION 9.1 OVERVIEW This chapter summarizes the administrative procedures necessary to implement the proposed land use plan, infrastructure improvements, development standards,

More information

THE INSTITUTE OF REFRIGERATION

THE INSTITUTE OF REFRIGERATION THE INSTITUTE OF REFRIGERATION Optimisation of Refrigeration and Heat Pump Designs for Meat Processing Plants By F J. BOWATER, MA. (CANTAB), C. ENG., M.I..MECH.E., M.I..Nuc.E., M.I.Mare.E. M.Inst.R. FJB

More information

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529 AS 60529 2004 IEC 60529 Ed 2.1:2001 AS 60529 Australian Standard Degrees of protection provided by enclosures (IP Code) This Australian Standard was prepared by Committee EL-026, Protective Enclosures

More information

Enclosures Appendix 1: Draft Golders Green Station Planning Brief. Summary

Enclosures Appendix 1: Draft Golders Green Station Planning Brief. Summary Policy and Resources Committee 23 February 2017 Title Report of Wards Status Urgent Key Golders Green Station Draft Planning Brief Cath Shaw Commissioning Director - Growth & Development Interim Deputy

More information

New Developments in the IEC61511 Edition 2

New Developments in the IEC61511 Edition 2 New Developments in the IEC61511 Edition 2 Presented by Dr Issam Mukhtar PhD(Eng.) TÜV FS Expert (IDNo.:117/06) 6 th May 2013 2010 Invensys. All Rights Reserved. The names, logos, and taglines identifying

More information

TESTS OF ADSIL COATING

TESTS OF ADSIL COATING TESTS OF ADSIL COATING Test B - Long Term Test FSEC-CR-1259-01 July 11, 2001 Prepared for: Bob Suggs Florida Power & Light Company 9250 W. Flagler Street Miami, Florida 33174 Principal Investigator Dr.

More information

Australian Standard. Security screen doors and security window grilles AS AS 5039

Australian Standard. Security screen doors and security window grilles AS AS 5039 AS 5039 2003 AS 5039 Australian Standard Security screen doors and security window grilles This Australian Standard was prepared by Committee CS-023, Security Screen Doors and Security Window Grilles.

More information

Certain Uncertainty - Demonstrating safety in fire engineering design and the need for safety targets.

Certain Uncertainty - Demonstrating safety in fire engineering design and the need for safety targets. Certain Uncertainty - Demonstrating safety in fire engineering design and the need for safety targets. Danny Hopkin 1, Ruben Van Coile 2 & David Lange 3 Introduction In his 2008 IAFSS plenary, Andy Buchannan

More information

Effectiveness of sprinklers in residential premises:

Effectiveness of sprinklers in residential premises: Effectiveness of sprinklers in residential premises: Section 7: Other considerations and Recommendations for further work Project report number 204505 Dr Corinne Williams and Dr Jeremy Fraser-Mitchell

More information

BUSINESS PLAN CEN/TC 58 SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS OR LIQUID FUELS EXECUTIVE SUMMARY

BUSINESS PLAN CEN/TC 58 SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS OR LIQUID FUELS EXECUTIVE SUMMARY Page: 1 BUSINESS PLAN CEN/TC 58 SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS OR LIQUID FUELS Scope EXECUTIVE SUMMARY Safety and control devices for equipment burning gaseous or

More information

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415 ASSESSMENT REVIEW Review of Assessment Report WFRA C91415 Fire resistance performance of steel electrical wall boxes mounted in plasterboard partitions with modified mounting arrangements, box design and

More information

PWYLLGOR CYNLLUNIO DYDDIAD: 23/03/2015 ADRODDIAD UWCH REOLWR GWASANAETH CYNLLUNIO AC AMGYLCHEDD CAERNARFON. Number: 1

PWYLLGOR CYNLLUNIO DYDDIAD: 23/03/2015 ADRODDIAD UWCH REOLWR GWASANAETH CYNLLUNIO AC AMGYLCHEDD CAERNARFON. Number: 1 Number: 1 Application Number: C14/1218/33/LL Date Registered: 12/01/2015 Application Type: Full - Planning Community: Buan Ward: Efailnewydd/Buan Proposal: CHANGE OF USE OF A FIELD TO FORM A TOURING CARAVAN

More information

TOWN AND COUNTRY PLANNING ACT 1990 (AS AMENDED).

TOWN AND COUNTRY PLANNING ACT 1990 (AS AMENDED). FAO: D. Williams Isle of Anglesey County Council Council Offices Llangefni Anglesey LL77 7TW 16 November 2017 DCRM Ref. No: WN0904-QUD-OS-LET-00002_English Dear Mr Williams TOWN AND COUNTRY PLANNING ACT

More information

volume 11 environmental assessment section 2 environmental impact assessment Part 7 ha 218/08

volume 11 environmental assessment section 2 environmental impact assessment Part 7 ha 218/08 DESIGN MANUAL FOR ROADS AND BRIDGES volume 11 environmental assessment section 2 environmental impact assessment Part 7 ha 218/08 glossary of terms Used in DMRB Volume 11, Sections 1 and 2 SUMMARY This

More information

Westinghouse UK AP1000 GENERIC DESIGN ASSESSMENT Resolution Plan for GI-AP1000-IH-01 Internal Fire Safety Case Substantiation.

Westinghouse UK AP1000 GENERIC DESIGN ASSESSMENT Resolution Plan for GI-AP1000-IH-01 Internal Fire Safety Case Substantiation. Westinghouse UK AP1000 GENERIC DESIGN ASSESSMENT Internal Fire Safety Case Substantiation MAIN ASSESSMENT AREA RELATED ASSESSMENT AREA(S) RESOLUTION PLAN REVISION GDA ISSUE REVISION Internal Hazards Civil

More information

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A. International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.800(19) Magnus Arvidson SP Fire Research SP Technical Research Institute

More information

Landscaping Securities August 28, 2014

Landscaping Securities August 28, 2014 Landscaping Securities August 28, 2014 The Office of the City Auditor conducted this project in accordance with the International Standards for the Professional Practice of Internal Auditing Office of

More information

Parish of Repton NEIGHBOURHOOD DEVELOPMENT PLAN

Parish of Repton NEIGHBOURHOOD DEVELOPMENT PLAN Parish of Repton NEIGHBOURHOOD DEVELOPMENT PLAN BASIC CONDITIONS STATEMENT December 2018 CEF 4 Legal Requirements This statement has been produced by the NDP Working Group on behalf of Repton Parish Council

More information

Planning Application 13/00952/FULLS at Ampfield Hill, Romsey, Test Valley: Great Crested Newt Survey Following on From Ecological Assessment

Planning Application 13/00952/FULLS at Ampfield Hill, Romsey, Test Valley: Great Crested Newt Survey Following on From Ecological Assessment 10 June 2014 Mr Allan Clark esq Ampfield Parish Council Blue Haze Ampfield Hill Ampfield Romsey SO51 9BD By email only Our Ref: P13/46 Dear Mr Clark Planning Application 13/00952/FULLS at Ampfield Hill,

More information

Development of land adjacent to Braggs Farm Lane and Rumbush Lane, Dickens Heath. Welcome. Today s exhibition. The proposal site

Development of land adjacent to Braggs Farm Lane and Rumbush Lane, Dickens Heath. Welcome. Today s exhibition. The proposal site Welcome Welcome to this event to discuss the development of land adjacent to Braggs Farm Lane. is currently in the preliminary stages of designing proposals to sensitively develop this site with high-quality

More information

Re: AHRI Comments on Proposed Addendum be to ASHRAE Standard 189.1

Re: AHRI Comments on Proposed Addendum be to ASHRAE Standard 189.1 January 31, 2013 Standing Standard Project Committee (SSPC) 189.1 Re: AHRI Comments on Proposed Addendum be to ASHRAE Standard 189.1 Dear Members of SSPC 189.1: These comments are submitted by the Air-Conditioning,

More information

PACKAGED COMMERCIAL WATERTUBE BOILERS

PACKAGED COMMERCIAL WATERTUBE BOILERS PACKAGED COMMERCIAL WATERTUBE BOILERS PACKAGED COMMERCIAL WATERTUBE BOILER American Boiler Manufacturers Association 4001 N. 9 th Street, Suite 226 Arlington, VA 22203-1900 703/522-7350 2003, American

More information

DRAFT REGULATORY GUIDE DG-1069 FIRE PROTECTION PROGRAM FOR NUCLEAR POWER PLANTS DURING DECOMMISSIONING AND PERMANENT SHUTDOWN

DRAFT REGULATORY GUIDE DG-1069 FIRE PROTECTION PROGRAM FOR NUCLEAR POWER PLANTS DURING DECOMMISSIONING AND PERMANENT SHUTDOWN 123-0083.htm at ruleforum.llnl.gov Page 1 of 27 This regulatory guide is being issued in draft form to involve the public in the early stages of the development of a regulatory position in this area. It

More information

Grower Summary PO 005

Grower Summary PO 005 Grower Summary PO 005 Column stocks (cut-flowers): An Investigation into the cause(s) of poor establishment, growth and flower uniformity in commercial crops. Annual 2011 Disclaimer AHDB, operating through

More information

The New EMC Directive 2004/108/EC

The New EMC Directive 2004/108/EC The New EMC Directive 2004/108/EC In the process of the review I have tried to spell out in words what is often referred to as a section number. This helps reduce the need to flip pages as one reads this.

More information

EAST OF ENGLAND OFFICE

EAST OF ENGLAND OFFICE Mr Philip Isbell Direct Dial: 01223 582751 Mid Suffolk District Council 131 high Street Our ref: P00524468 Needham Market Ipswich Suffolk IP6 8DL 18 January 2017 Dear Mr Isbell T&CP (Development Management

More information

TetraTek, Inc. Regulatory. Compliance. Emergency Response. Nuclear Facility Compliance. Compliance. Fire Protection.

TetraTek, Inc.   Regulatory. Compliance. Emergency Response. Nuclear Facility Compliance. Compliance. Fire Protection. has in-depth experience with support services throughout the DOE Complex, Power and Enrichment Fuel Cycle industries. With hands-on experience and our policy-making process in the development of National

More information

Great Easton Neighbourhood Plan Statement of Basic Conditions

Great Easton Neighbourhood Plan Statement of Basic Conditions Great Easton Neighbourhood Plan 2017-2031 Statement of Basic Conditions OCTOBER 2016 GREAT EASTON PARISH COUNCIL Contents 1.0 Introduction....Page 2 2.0 Summary of Submission Documents and Supporting Evidence..

More information

Effective Alarm Management for Dynamic and Vessel Control Systems

Effective Alarm Management for Dynamic and Vessel Control Systems DYNAMIC POSITIONING CONFERENCE October 12-13, 2010 OPERATIONS SESSION Effective Alarm Management for Dynamic and Vessel Control Systems By Steve Savoy Ensco Offshore Company 1. Introduction Marine control

More information