Operating Manual JuniorPower

Size: px
Start display at page:

Download "Operating Manual JuniorPower"

Transcription

1 To be read completely before start-up! Operating Manual JuniorPower 12/04 von Oertzen GmbH Ferdinand-Harten-Str Ammersbek Tel Fax

2 Table of Contents 1. Introduction page 3 2. Safety Instructions page Description/Illustrations page Start-up/Operation/Shut-down page Maintenance and Care page Electric Wiring Diagram page Technical Data page Trouble Shooting page Declaration of Conformity page 22 JuniorPower-10/03-AG-VS-12/04 2

3 1. Introduction The OERTZEN high pressure cleaner model JUNIORPOWER is one of the most durable and reliable machines available on the market. Its balanced ratio of water flow (temperature) and working pressure meets all cleaning requirements. The OERTZEN high pressure cleaners conform to all and European safety regulations which is guaranteed by the CE symbol. This manual to be made available to the operating personnel and to be read completely before start-up. We underline that we cannot be held responsible for any damages or malfunctions as a result of ignoring this manual. OERTZEN offers training courses in order to enable the operating personnel to run the machine in accordance with the instructions laid down in this manual, to carry out all necessary maintenance work described herein and to eliminate minor repair work. This warning symbol appears in this operating manual at all operating and safety instructions dealing with the dangers for personal entirety and life (DIN 4844). This warning symbol appears in the operating manual at all operating and safety instructions dealing with the fulfilment of rules, regulations and instructions for the proper operation and to avoid damages or destroying of the machine. This manual is subject to alteration. All rights reserved. Any use in other than legally authorised cases requires the prior written approval of ARNDT H. von OERTZEN (GmbH&Co). 3

4 2. Safety Instructions Before initial start-up this manual to be read completely and thoroughly. If all instructions laid down herein are strictly followed, no danger should occur. The machine must only be run by qualified and skilled personnel. All relevant national safety regulations to be followed. The machine is not suitable for unattended operation. Protective clothes to be worn. The water jet out of the spray pistol has a dangerous cutting effect! Water jet not to be directed onto persons, animals electrical components and must not be used for cleaning of clothes, shoes etc. When starting the machine, be aware of torque and recoil. Ensure secure foothold. Repair and/or maintenance work in the high pressure section (pump, HP-hoses, pipes) must only be carried out by qualified personnel. Before dismantling the machine in case of e.g. malfunctions unit to be stopped by means of the ON/OFF switch and to be disconnected from electric power source. The max. pressure stated on the type label not to be exceeded. The unloader valve opens in case the operating pressure is exceeded by 10 % and directs the water back to the suction side of the pump. The unloader valve is workshop-adjusted and sealed. The adjustment not to be changed. Unsuitable or defective hoses often cause accidents during operation with high pressure units. Defective hoses to be replaced immediately by Original OERTZEN equipment. Use of other hoses than those originally delivered or expressively approved by OERTZEN ceases warranty, product liability and validity of the Declaration of Conformity. Worn-out high pressure hoses must not be repaired and re-used but replaced immediately. Use of other detergents, spare parts and/or materials than those originally delivered or expressively approved by OERTZEN ceases warranty, product liability and validity of the Declaration of Conformity. Spray pistols with delayed closing mechanism are dangerous and must not be used. Lever in open position must not be blocked or fixed in any other way. During working with spray lances shorter than 750 mm particular dangers to be considered. After completion of work spray pistol to be secured against accidental/unauthorised operation by means of the safety lever. The unit must not be run in areas which are jeopardised by fire or explosions. All relevant safety regulations to be followed. 4

5 Consumables to be handled thoroughly strictly in accordance with relevant technical and environmental safety regulations. Electric power can cause severe injuries. Defective electrical components to be replaced immediately and possible causes for accidents to be eliminated. Repair work to be carried out by qualified personnel. Disconnect the machine from electric power source during repair/maintenance work. Only correctly dimensioned cables according to VDE regulations to be used. Cables on reels to be reeled off totally during operation in order to avoid overheating of the reel. Plugs and couplings to be water-proof. A faulty current protection switch to be foreseen. Machine not to be started in case power cable, plugs, switches, etc. are defective. Machine must not move. It is equipped with a brake which must be activated when working in steep areas. During loading proper hoisting device to be used. Ensure balanced load. When using pipe cleaning hoses observe markings during moving hose in or out (approx. 50 cm). Strictly follow the instructions as per chapter Operation Pipe Cleaning. Exhaust evacuation line gets hot. Do not touch. Indoor operation of oil-heated high pressure units without proper ventilation and exhaust evacuation is forbidden! Exhaust fumes are hazardous! 5

6 3. Description/Illustrations The hot water model JuniorPower mainly consists of an inline high pressure pump with safety-shut-down system, as well as a high performance, double shell vertical heat exchanger. The inline high pressure pump is directly flanged to the electric motor. It sucks the feed water from an integrated level-controlled storage tank and directs it under high pressure via a safety/control valve into a heating coil which heats up the passing water to operating temperature. The sealed safety/control valve which is arranged between high pressure pump and heating coil opens as soon as the working pressure is exceeded by more than 10 % and returns the water which is not taken by the nozzle to the suction line of the high pressure pump. By activating the burner/temperature adjusting switch the fuel pump sucks fuel oil from the fuel oil storage tank via a filter system and injects it under defined pressure through the oil nozzle into the burner chamber. The blower presses the oxygen which is needed for the combustion process into the burner chamber, where the mixture is atomised and ignited by ignition electrodes which are continuously energised by a high-voltage transformer. The heating flame burns in the burner chamber without touching the shells and without soot formation at high efficiency. Infrared radiation generated by this process and hot exhaust fumes cause an economic heating of the water passing through the heating coil up to the working temperature adjusted on the thermostat. At the high pressure outlet the hot water enters high pressure hose, spray lance and spray nozzle. Working pressure is achieved by the fixed diameter of the spray nozzle and can continuously be adjusted as required by turning the rotary handle at the double lance. The steam mode allows operation with hot water of more than 100 C at reduced flow. If required, a suitable detergent can be sucked from the detergent tank via filter and non-return valve and applied onto the cleaning object by the water jet by opening the detergent dosing valve. In order to protect the machine against formation of scale deposits, it is equipped with an anti-scalant/liquid softening system which continuously doses softening liquid into the water storage tank. This high pressure cleaner is equipped with an automatic start-/stop system. When closing the spray pistol the machine remains in circulation mode for approx. 15 seconds and then switches over into "stand-by mode". In parallel the a safety/control unit interrupts the fuel supply to the burner which is so stopped. When activating the spray pistol again, the machine and burner system start and pressure is generated immediately, so that the cleaning procedure can be continued without delay. The machine can be used more effectively by adding proven accessories. Please contact your OERTZEN dealer for further information. 6

7 Symbols water inlet fuel oil/diesel electric shock softening liquid earthing detergent burner mode high press. outlet Legend for Illustrations on Page 8 1 Electric motor 13 Oil sight glass 2 ON/OFF switch 16 Detergent dosing valve 3 Safety-/control valve 17 Detergent tank 4 Pressure indicator 19 Fuel tank 6 Water inlet/pre-filter 21 Blower 8 High pressure pump 22 Fuel pump/micro-filter 9 Water storage tank 23 Burner/thermostat switch 11 High pressure water outlet 24 Boiler outlet 12 Oil filling hole/dip stick 28 Liquid softener tank 7

8 8

9 4. Start-up /Shut-down Before start-up: Before starting an OERTZEN hot water machine, the following to be noted: Proper ventilation and exhaust evacuation to be guaranteed. Due to the electric configuration the correct direction of rotation of the burner motor to be guaranteed. Changes to be carried out by qualified electrical engineers. Operating manual to be read completely, instructions to be followed. Correct oil level of high pressure pump to be checked (sight glass (13) / dip stick (12)) Only oil qualities approved by OERTZEN to be used. Machine only to be run with clean water. Water supply hose to be flushed before connection. Water filter to be checked in short regular intervals. Machine only to be run horizontally (± 5 ). In order to ensure proper condition and trouble-free operation the following checks to be carried out before, during and after work: General condition of the machine (screw fixings, protection caps, etc). Power cable/electric connections. Indicator lamps. Pump/connections leaking? High pressure hoses, supply hoses, etc. damaged? Water supply, water filter. Air supply. Tanks filled? Abnormal noise? The JuniorPower is equipped with an automatic start/stop system with timer-controlled lag. During extended shut-down periods the machine in general to be switched off by means of the ON/OFF switch (2). Spray pistol to be de-pressurised and secured by means of the safety lever. In case of malfunctions machine to be switched off immediately. Eliminate cause according to chapter "Trouble-Shooting", respectively call qualified service. 9

10 Connections Water Connection Water inlet (6) to be connected to the water source with a clean supply hose (diameter as per table below). Water supply hose to be flushed with clean water before connection. If machine to be connected to the potable water distribution system, a backflow preventer with non-return protection and ventilation to be installed). Water flow pressure Min. flow * Minimum: 2 bar 15 l/min " supply hose Maximum: 8 bar 21 l/min 1" supply hose 30 l/min 1 " supply hose * s. Techn. Data Insufficient water supply will cause severe damage on the high pressure pump (cavitation). Electric Connection Unit to be connected to a 400 V power source, protected by 3 x 16 A fuse (slow). Only correctly dimensioned cables according to DIN to be used. Cables on reels to be reeled off totally during operation in order to avoid overheating of the reel. A faulty current protection switch to be foreseen. VDE regulations to be followed. High Pressure Connection High pressure hose to be connected by means of the hand nut hand tight to the high pressure outlet (11) without using tools. Fuel Tank The fuel tank (19) to be filled with clean fuel oil according to DIN 51603, part 1 or Diesel. Ensure absolute cleanliness during transport and filling. After filling the tank to be closed properly. Softening tank Tank (28) to be filled with OERTZEN softening liquid ORM 30. Machine never to be run with empty tank. After filling tank to be closed properly. Detergent Tank Detergent tank (17) to be to be filled with a detergent approved by OERTZEN. Detergent powders to be diluted in water without lumps before being filled into detergent tank. After filling tank to be closed properly. 10

11 Operation Open water cock. Unlock and release spray pistol, bleed machine until water emerges without blistering. Turn ON/OFF switch (2) into Pos. I. Adjust burner thermostat (23) to required working temperature. Carry out cleaning job. Be aware of torque and recoil. Be aware of hot exhaust fumes. Steam Mode Turn ON/OFF/burner switch (23 a) to maximum working temperature. Pull steam valve (26) upwards and block it by turn clockwise. Be aware of hot steam emerging from the machine. Pressure Regulation (in general) Pressure can continuously be adjusted as required by turning the rotary handle at the double lance. Counter-clockwise: Clockwise: pressure decrease pressure increase In case machine is being moved while burner is in operation, be aware of hot exhaust fumes emerging from the boiler outlet! 11

12 Detergent Mode Only approved, harmless detergents to be used. Use of not approved, hazardous detergents ceases warranty obligations. Detergents can be used in cold and hot water mode. Manufacturers instructions to be followed. Adjusting knob on detergent dosing valve (16) to be adjusted to required concentration. Detergent to be applied onto cleaning object from the bottom to the top. Detergent to work in, but must not dry. Turn detergent dosing valve (16) into position 0. Wash cleaning object with high pressure stream from the bottom to the top. Keep a distance of cm. Detergent residues to be rinsed properly from the cleaning object. Detergent must not be applied on hot surfaces or in direct sunlight. Detergent must not dry. After completion of work detergent dosing valve to be closed and detergent line to be flushed until no detergent residues can be detected in the water stream. 12

13 After Work Burner thermostat switch (23) to be turned into Pos. 0. Machine to be run in cold water mode for several minutes. Close spray pistol. Switch of machine by means of the ON/OFF switch (2 in Pos. 0). De-pressurise spray pistol shortly opening and closing. Lock spray pistol. Disconnect machine from power and water source. High pressure hose to be cleaned thoroughly. In case of damages (cracks, kinks, etc.) hose to be replaced by original OERTZEN equipment. Use of other hoses than those originally delivered or expressively approved by OERTZEN ceases warranty, product liability and validity of the Declaration of Conformity. High pressure hose to be reeled up properly. Machine and accessories to be stored in a dry and frost-protected area. In case of extended shut-down periods pump to be drained completely. Note in particular: In case of malfunctions switch off machine immediately. Eliminate cause according to chapter "Trouble-Shooting" respectively call qualified service. During extended working breaks and after completion of work machine to be switched off by means of the ON/OFF switch (2). Frost protection is essential, as otherwise severe damage on the pump may occur. After work protect the spray pistol against accidental/unauthorised use by means of the safety lever. 13

14 5. Maintenance and Care Every machine is only as reliable as maintenance instructions are followed. The following maintenance work to be carried out in regular intervals: Ignoring the maintenance instructions described below ceases all warranty obligations. High Pressure Pump First oil change to be carried out after 50 operating hours, followed by further oil changes every 500 operating hours. In case the oil is getting milky due to condensation, switch off machine immediately and change oil. In the event of recurrence all seals of the pump to be changed. For OERTZEN high pressure pumps only OERTZEN OSP special pump oil to be used. Use of oil qualities not approved by OERTZEN ceases all warranty obligations. OERTZEN OSP special pump oil can be obtained from your local OERTZEN service point. 14

15 Water Filter In the water inlet there is a pre-filter (6) arranged which must be checked before start-up and replaced, whenever required. Operation with polluted feed water and/or clogged water filter can cause severe damage on high pressure pump and control elements. Fuel Filter Between fuel pump and fuel tank there is a filter installed, which must be replaced whenever required. Fuel Pump Strainer of the fuel pump (22) to be cleaned or replaced whenever required. Fuel Tank Dirt and water deposits inside the fuel tank (19) to be regularly removed. Boiler Cleaning In case the machine gives off sooty smoke, it must be stopped immediately (danger of explosion). Heating coil and pre-heater to be cleaned whenever required, at least as soon as soot deposits can be detected on the heating coil. Boiler cleaning only to be carried out by qualified personnel. De-Scaling The JuniorPower is equipped with an anti-scalant system which avoids formation of scale deposits to a great extent. In order to guarantee proper functioning of the anti-scalant device the tank to be checked and refilled whenever required. Only OERTZEN ORM 30 softening liquid to be used. In case of high water hardness, at least every 300 operating hours the water-boiler-system to be flushed with an anti-scalant during normal maintenance work. 15

16 Maintenance Intervals Works to be carried out Pump oil OSP First oil change H.P. pump Further oil changes H.P. pump To be checked/cleaned by operators To be carried out by qualified service personnel, min. every... operating hrs 50 hrs 100 hrs 200 hrs 500 hrs/once per year Water filter Fuel filter Fuel pump (strainer) Fuel tank Boiler Heating coil Water tank Ignition electrodes Burner nozzle Total safety check = replacement = cleaning = to be carried out All maintenance intervals stated apply under the condition that the machine is run with clean water according to instructions. Otherwise shorter intervals are needed Ignoring the maintenance instructions described before ceases all warranty obligations. Therefore, strictly following maintenance instructions is of vital interest. 16

17 Frost Protection Frost protection is a must, because frost may cause severe damage on the machine and hazardous operation as otherwise heavy damage on the entire water system may be the result. The best frost protection is to store machine and accessories in a frost protected area. Frost protection to be carried out as follows: Machine to be started, spray pistol to be opened, water source to be closed. Wait until pressure drops and stop the machine. Fill approx. 3 l of a commercial frost protection liquid (Glysantin) into the water storage tank. Start the machine, open and close the spray pistol several times until frost protection liquid emerges. Stop the machine. The system is now protected against temperatures of 25 C Ignoring frost protection instructions can cause severe damage on the entire system. 17

18 6. Electric Wiring Diagram 7. Technical Data Technical Data JuniorPower Flow rate / adjustable 800 l/h Unloading pressure * 180 bar Max. working pressure / adjustable 160 bar Water temperature / adjustable **** C Normal current (50 Hz) 3 ~ 400 V Total connected load 5,3 kw Power consumption 8,5 A Heating capacity 40 kw Fuel consumption 3,9 kg/h Spray nozzle 2545 Ssyst. Recoil ** 42 N Noise level Lp *** / Lw *** 75 / 93 db(a) Abmessungen (L x B x H mm) 980 x 670 x 810 Weight 88 kg Order-No * Setpoint of unloading control ** Depending on length and angle of spray lance, torque occurs which has to be controlled by a tight grip. *** according to DIN ISO 3744 **** max. 140 C, 32 bar, at fully opened safety/control valve Standard Equipment: 10 m high pressure safety hose, insulated spray pistol, insulated double lance Subject to technical alteration. 18

19 8. Trouble Shooting Electric power can cause severe injuries. Defective electrical components to be replaced immediately and possible causes for accidents to be eliminated. Repair work to be carried out by qualified personnel. Disconnect the machine from electric power source during repair/maintenance work. Only original OERTZEN spare parts and accessories to be used. Use of other materials ceases all warranty obligations. Malfunction Cause Remedy Machine does not start. - Machine not connected to electric power source. Machine suddenly stops. - Fuse burnt. - Phase missing. - Overload protection activated. - Fuse defective. - Overload protection activated. - Water shortage (control lamps illuminated) - Press motor protection switch. - Insert electric plug, Activate main switch. - Change fuse. - Mount phase according to electric wiring diagram. - Cool down motor. - Change fuse. - Cool down motor. - Ensure water supply, restart machine by means of ON/OFF switch. Electric motor noises during start-up. Working pressure not achieved/varies - Micro leakage. (contr. lamp illuminated) - Low voltage. - Motor protection switch defective. - Operating pressure too high. - Fuse burnt (phase missing). - Fault in electric network - Air in machine - Water shortage - Tighten leakage. - Ensure correct voltage. - Call qualified service. - Clean / replace nozzle (see Technical Data). - Change fuse. - Check. - Bleed machine Open pressure regulation handle/pistol until continuous pressure is achieved. - Diameter of supply hose incorrect. (see table on page 12) - Nozzle worn - Incorrect nozzle - Nozzle clogged - Water filter clogged - Unloader valve leaking - Suction side leaking - Replace nozzle. - Install correct nozzle. - Clean nozzle - Clean filter - Call qualified service - Properly fix hose clamps on suction hose - Clean valves. - Suction valves sticking/dirty. Vibrations on high pressure hose/pistol - Air in machine - Bleed machine Open pressure regulation handle/pistol until continuous pressure is achieved. - Clean water filter. Machine does not start after Total Stop. (control lamp illuminated) No detergent injection Burner does not start. Temperature not achieved. - Total Stop function activated. - Restart according to instructions on page 8 - Detergent tank empty. - Fill tank. - Pressure regulation handle closed. - Open handle. - Detergent dosing valve closed. - Open valve. - Incorrect direction of rotation burner motor - Fuel tank empty. - Thermostat incorrectly adjusted. - Fuel filter clogged - Direction of rotation to be corrected by qualified electrical engineers - Fill tank. - Adjust correctly. - Clean filter. Excessive exhaust formation. - incorrect burning procedure. - Clean fuel filter. - Call qualified service. 19

20 20

Operation Manual 322 KL

Operation Manual 322 KL Operation Manual 322 KL 8/07 von Oertzen GmbH Ferdinand-Harten-Str. 10 22949 Ammersbek Tel. +49 40 604110 Fax +49 40 6041149 www.oertzen-gmbh.de info@oertzen-gmbh.de Table of Content 1. Introduction Page

More information

Operation Manual/ Spare Parts List High Pressure Fire Extinguisher OERTZEN HDL 170 S HDL 200

Operation Manual/ Spare Parts List High Pressure Fire Extinguisher OERTZEN HDL 170 S HDL 200 Operation Manual/ Spare Parts List High Pressure Fire Extinguisher OERTZEN HDL 170 S HDL 200 von Oertzen GmbH Ferdinand-Harten-Str. 10 22949 Ammersbek/Germany Tel. +49 40 604 11-0 Fax +49 40 604 11 49

More information

PJ130S High Pressure Cleaner

PJ130S High Pressure Cleaner PJ130S High Pressure Cleaner Operator Manual Original instructions WARNING: Do not use the machine without reading the instruction sheet. Item Description OVERVIEW 1. High pressure washer 2. On/off switch

More information

Operation Manual/ Spare Parts List/Accessories High Pressure Fire Extinguisher OERTZEN HDL 250 WS 1/06

Operation Manual/ Spare Parts List/Accessories High Pressure Fire Extinguisher OERTZEN HDL 250 WS 1/06 Operation Manual/ Spare Parts List/Accessories High Pressure Fire Extinguisher OERTZEN HDL 250 WS 1/06 von Oertzen GmbH Ferdinand-Harten-Str. 10 22949 Ammersbek/Germany Tel. +49 40 604 11-0 Fax +49 40

More information

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS PW1370TD 2 EN Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS 3 E3 E1 C3 A1-A2-A3-A4 B4 B1 B5 B2 C1 B3 D 1 4 1 2 3 4 5 6 7 Ø13

More information

APW-VAP-150P High Pressure Cleaner Operator Manual

APW-VAP-150P High Pressure Cleaner Operator Manual APW-VAP-150P High Pressure Cleaner Operator Manual BEFORE OPERATING THIS APPLIANCE PLEASE READ THESE INSTRUCTIONS CAREFULLY Item Description OVERVIEW 1. High pressure washer 2. On/off switch 3. Water outlet

More information

DH-Direct Fired Poultry Farm Diesel Heater

DH-Direct Fired Poultry Farm Diesel Heater DH-Direct Fired Poultry Farm Diesel Heater Comparison of Diesel Heater to Gas Heater Diesel LPG Gas LPG Gas KW 43 70 120 Fuel consumption/hr 3 5.1 8.8 Heat output 37000 60000 100000 Cost of fuel/lit or

More information

HOT WASHER MODEL NO: KING150

HOT WASHER MODEL NO: KING150 WARNING: Do not use the hot washer without reading this manual HOT WASHER MODEL NO: KING150 PART NO: 7320175 OPERATION & MAINTENANCE INSTRUCTIONS LS1215 INTRODUCTION Thank you for purchasing this CLARKE

More information

HD 525 S 06/03 A ! 5.960

HD 525 S 06/03 A ! 5.960 HD 525 S 5 960 845 A2005225 06/03! Please read these operating instructions before starting and strictly observe the Safety Instructions for High Pressure Cleaners (5.951-949). WARNING DO NOT SPRAY ELECTRICAL

More information

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings Contents 1. General Warnings --------------------- 1 2. Safety Warnings ----------------------- 2 3. Parts and structure --------------------- 7 4. Safety Device ------------------------- 9 5. Checkups

More information

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...

More information

F /98

F /98 5.959 028 F14398 04/98 2 1. Starting 1. Starting 1 Connection lead 2 Appliance switch (ON/OFF) 3 High-pressure outlet 4 Carrying handle 5 Water connection 6 Water filter 7 Coupling 8 High-pressure hose

More information

SuperMagnum 270 ELC Hot Water High-Pressure Cleaner

SuperMagnum 270 ELC Hot Water High-Pressure Cleaner SuperMagnum 270 ELC Hot Water High-Pressure Cleaner Technical data SuperMagnum 270 ELC Flow rate max. 1320 l/h Unloading pressure 230 bar Working pressure max. 210 bar Water temperature 30-140 C Start/Stop

More information

RX550i Electric Pressure Washer

RX550i Electric Pressure Washer RX550i Electric Pressure Washer READ THIS MANUAL CAREFULLY BEFORE USE FAILURE TO DO SO MAY RESULT IN INJURY, PROPERTY DAMAGE AND MAY VOID WARRANTY. KEEP THIS MANUAL FOR FUTURE REFERENCE. Products covered

More information

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them. K 1.100 Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. www.kaercher.com/register-and-win 59651430 (10/13) Contents General information..............

More information

en Direct oil-fired space heaters HD... Operator's manual

en Direct oil-fired space heaters HD... Operator's manual 0211670en 002 12.2007 Direct oil-fired space heaters HD... Operator's manual Table of contents 1. Foreword 5 2. Safety information 6 2.1 General recommendations... 6 2.2 Safety devices... 7 2.3 Labels...

More information

Glass and Dishwashers AMX / AUX Series

Glass and Dishwashers AMX / AUX Series Glass and Dishwashers AMX / AUX Series INSTALLATION OPERATION REV. 8.xx 04.07.2005 Installation and Operation Instructions for Models of AMX / AUX Series Content Page 1 Installation... 3 2 Connections...

More information

Carmen. Operating Instructions. 1

Carmen. Operating Instructions.  1 Carmen Operating Instructions Streamline Supplies 9 Joseph Baldwin Place, Shepparton Victoria Ph: Fax: www.streamlinesupplies.com.au Introduction Please read this technical handbook carefully since it

More information

HDS 2.3/12 C Ed /14

HDS 2.3/12 C Ed /14 HDS 2.3/12 C Ed www.kaercher.com/register-and-win 59662810 01/14 1 26 27 28 29 30 31 1 25 2 3 24 4 5 23 22 4 21 20 19 13 4 14 15 16 17 18 12 9 8 11 10 8 7 6 2 MIN 32 33 MAX 41 35 34 36 37 38 39 40 3 2

More information

HX-30/40 and HX-30/40 S Glass and Dishwashers

HX-30/40 and HX-30/40 S Glass and Dishwashers HX-30/40 and HX-30/40 S Glass and Dishwashers INSTALLATION OPERATION VERSION 18/01/00 2 Installation and Operation Instructions for Model HX-30/40 and HX-30/40 S (with built-in softener) Content Page 1

More information

Portable Pressure Washer

Portable Pressure Washer RX550i Thanks for purchasing our latest portable pressure washer. Whether it be for light rinsing or for power stripping, this pressure washer is built for quick and easy high speed cleaning. To get the

More information

K 5.80 M ( ) Caution! Do not use the unit without first having read the operating instructions.

K 5.80 M ( ) Caution! Do not use the unit without first having read the operating instructions. K 5.80 M 5.960-830 (2004330-04-03) Caution! Do not use the unit without first having read the operating instructions. Contents Short instructions... 2 Assembly... 3 Safety Notes... 4 Before first use...

More information

ORIGINAL INSTRUCTIONS

ORIGINAL INSTRUCTIONS WARNING: Read the instructions before using the machine. POWER WASHER MODEL NO: JETSTAR 1950 PART NO: 7336010 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0617 - ISS 3 INTRODUCTION Thank

More information

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO: WARNING Read the instructions before using the machine PRESSURE WASHER MODEL NO: JETSTAR 1750 PART NO: 7333230 OPERATION & MAINTENANCE INSTRUCTIONS LS0711 INTRODUCTION Thank you for purchasing this CLARKE

More information

Glass and Dishwashers AMX / AUX Series

Glass and Dishwashers AMX / AUX Series Glass and Dishwashers AMX / AUX Series INSTALLATION OPERATION VERSION 24.02.04 Important Notes Use in Accordance with Regulations This machine is exclusively to be used to wash ware such as plates, cups,

More information

SAFETY AND OPERATING MANUAL

SAFETY AND OPERATING MANUAL SAFETY AND OPERATING MANUAL HOT WATER ELECTRIC WATER BLASTERS Read Safety & Operating Instructions Before Commencing Operation THESE INSTRUCTIONS MUST BE READ AND ADHERED TO BEFORE OPERATING THIS MACHINE.

More information

K 2.50 M. Operating Instructions PRESSURE WASHER /03_

K 2.50 M. Operating Instructions PRESSURE WASHER /03_ K 2.50 M 5.960 643 05/03_2004246 Operating Instructions PRESSURE WASHER Before first use of the unit read these operating instructions and act in accordance with them ! Safety Notes! Use of the unit as

More information

Infrared Diesel Heater

Infrared Diesel Heater Infrared Diesel Heater Model No: IRD40 PART NO: 6920415 OPERATING & MAINTENANCE INSTRUCTIONS GC0812 INTRODUCTION Thank you for purchasing this CLARKE Diesel Infrared Heater. Before attempting to use the

More information

K 2.900M. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them

K 2.900M. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them K 2.900M Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. 5.961-933.0 01/07 2 Dear Customer, Please read and comply with these instructions

More information

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

User Manual GV25 GV35 GV702. Company information:   Original instructions GV12066 (1) User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual

More information

High Pressure Washer 130

High Pressure Washer 130 High Pressure Washer 130 7901 WARNING: Do not use the appliance without reading this instruction sheet ORIGINAL INSTRUCTIONS Hozelock Ltd. Midpoint Park Birmingham, B76 1AB. England Tel: +44 (0) 121 313

More information

Compact Pressure Washer 100

Compact Pressure Washer 100 Compact Pressure Washer 100 7900 WARNING: Do not use the appliance without reading this instruction sheet ORIGINAL INSTRUCTIONS Hozelock Ltd. Midpoint Park Birmingham, B76 1AB. England Tel: +44 (0) 121

More information

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove HEATING TECHNIQUE Centrometal d.o.o. - Glavna 12, 40306 Macinec, Croatia, tel: +385 40 372 600, fax: +385 40 372 611 TECHNICAL INSTRUCTIONS for regulation, use and maintenance of pellet stove CentroPelet

More information

HD 4.5/32-4S Eb HD 4.5/32-4S Ec. Register and win! /13

HD 4.5/32-4S Eb HD 4.5/32-4S Ec. Register and win! /13 HD 4.5/32-4S Eb HD 4.5/32-4S Ec Register and win! www.kaercher.com 59658610 04/13 2 IMPORTANT SAFETY IN- STRUCTIONS WARNING When using this product basic precautions should always be followed, including

More information

EH W Pressure Washer

EH W Pressure Washer EH1684 1600W Pressure Washer 1 IMPORTANT Installer and Users please note: These instructions should be read carefully and left with the user of the product for future reference. BEFORE USE You must inspect

More information

Glass and Dishwashers. BarAid 500/800. Installation and. Starting from Serial No.:

Glass and Dishwashers. BarAid 500/800. Installation and. Starting from Serial No.: Glass and Dishwashers BarAid 500/800 Installation and operation Instructions Starting from Serial No.: 8652 0001 REV. 19.01.2009 1617-A-01-09 Content Page 1 Important Notes... 4 2 Installation... 5 2.1

More information

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions. High-Pressure Washer BY02-VBP-WTH BY02-VBP-WTR CAUTION : Do not use this device before reading the instructions. 1 1. Safety Instructions The appliance has been designed solely for private use outdoors

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

DUST EXTRACTOR MODEL No: CDE1000

DUST EXTRACTOR MODEL No: CDE1000 DUST EXTRACTOR MODEL No: CDE000 Part No:64765 OPERATING & MAINTENANCE INSTRUCTIONS GC054 INTRODUCTION Thank you for purchasing this CLARKE Dust Extractor which is intended to keep work areas free from

More information

Rack conveyor dishwashing machine STR. Operating instructions

Rack conveyor dishwashing machine STR. Operating instructions Rack conveyor dishwashing machine STR Operating instructions Operating Instructions for Winterhalter STR Rack Conveyor Dishwashing Machine (translation of the original German operating instructions) Table

More information

Light oil burners. One stage operation

Light oil burners. One stage operation Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR

More information

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.: Glass and Dishwashers ECOMAX 402/452/502 (incl. Australian 452-90/502) INSTALLATION AND OPERATION INSTRUCTIONS (original instructions) Starting from Serial No.: 8663 4000 REV. 05.10.2015 EN IMPORTANT NOTES

More information

E-COMBI EVO E-SYSTEM EVO

E-COMBI EVO E-SYSTEM EVO E-COMBI EVO E-SYSTEM EVO User s manual CONDENSING WALL-HUNG GAS BOILER G.C.N.:47-116-68 (24 kw) G.C.N.:47-116-69 (30 kw) G.C.N.:47-116-70 (38 kw) G.C.N.:41-116-39 (24 kw) G.C.N.:41-116-40 (30 kw) Country

More information

High Pressure Washer - SAFETY INSTRUCTIONS

High Pressure Washer - SAFETY INSTRUCTIONS High Pressure Washer - SAFETY INSTRUCTIONS Nilfisk DOC0023 REV A 1 Symbols used to mark instructions WARNING & Safety instructions in these operating instructions which must be observed to prevent risks

More information

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data Instruction manual Submersible sump pump Safety instructions Application Electrical connection Installation Maintenance Technical data U 3 K /2 U 3 KS /2 U 3 K spezial /2 U 3 KS spezial /2 U 5 K /0 U 5

More information

Heavy Duty Pressure Washer 150

Heavy Duty Pressure Washer 150 Heavy Duty Pressure Washer 150 7902 WARNING: Do not use the appliance without reading this instruction sheet Hozelock Ltd. Midpoint Park Birmingham, B76 1AB. England Tel: +44 (0) 121 313 1122 info@hozelock.com

More information

Operational Instructions. Glue Applicator MS Translation from German to English

Operational Instructions. Glue Applicator MS Translation from German to English Operational Instructions Glue Applicator MS 200 Translation from German to English Table of Contents Product Description 1 General Safety Instructions 2 Safety Measures to be taken during Operation 3 Start-up

More information

KB Operating Instructions. Before first use of the unit Please read these /07

KB Operating Instructions. Before first use of the unit Please read these /07 KB 6060 Operating Instructions Before first use of the unit Please read these Operating Instructions and act in accordance with them 5.962-095.0 01/07 2 Dear Customer, Please read and comply with these

More information

HD 650/SX HD 658 HD 690/SX A /02

HD 650/SX HD 658 HD 690/SX A /02 HD 650/SX HD 658 HD 690/SX www.karcher.com 5.959-798 A2003483 05/02 HD 650 / 658 / 690 HD 650 SX / 690 SX 4 5 English Unit parts Operating Instructions HD 650 (SX) / HD 658 / HD 690 (SX) Use of the cleaner

More information

HD 645 HD 650/SX HD 658 HD 690/SX A /04

HD 645 HD 650/SX HD 658 HD 690/SX A /04 HD 645 HD 650/SX HD 658 HD 690/SX www.karcher.com 5.960-848 A2008107 03/04 Deutsch English Français Italiano Nederlands Español Português Svenska Suomi ÅëëçíéêÜ Pºcc å¼ Polski 6 17 28 40 52 63 75 87 97

More information

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20D-30D-50D-60D-100D-TC-001-EN Table of contents Notes regarding the operating manual... 1 Safety... 2 Information

More information

Pico Power Pressure Washer

Pico Power Pressure Washer 7920 Pico Power Pressure Washer www.hozelock.com? Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: 01702 482 760 www.hozelock.com 33608-000 2 Year guarantee Contents A B D C E F G H I J K

More information

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO: WARNING: Do not use the machine without reading this manual POWER WASHER MODEL NO: JET 9000 PART NO: 7333502 OPERATION & MAINTENANCE INSTRUCTIONS GC0913 INTRODUCTION Thank you for purchasing this CLARKE

More information

Contents. Safety instructions. Device elements. Colour coding. Hazard levels

Contents. Safety instructions. Device elements. Colour coding. Hazard levels Please read and comply with these original instructions prior to the initial operation of your appliance and store them for later use or subsequent owners. Contents Device elements........... EN 1 Safety

More information

model No: ir20.v2 FUSE

model No: ir20.v2 FUSE InstructioNS for: model No: ir20.v2 INFRARED PARAFfIN / KEROSENE / diesel HEATER 70000Btu 230V Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according

More information

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance MW001 Integrated Dishwasher Manual for Installation, Use and Maintenance Important The CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation of this product.

More information

1. GENERAL SAFETY RULES

1. GENERAL SAFETY RULES ID180 & ID290 Indirect-Fired Diesel/Oil Construction Heaters Sure Flame Products Lethbridge, Alberta, Canada Telephone: (403)328-5353 Fax: (403)328-9956 www.sureflame.ca July 12, 2006 Service and Maintenance

More information

Installation & Maintenance Manual

Installation & Maintenance Manual Installation & Maintenance Manual MOL 200 S1L (B30A) Oil Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk DESCRIPTION COMPONENTS 1. Shrouded

More information

Tempest TP420/180 Electric Pressure Washer

Tempest TP420/180 Electric Pressure Washer Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Operating Instructions

Operating Instructions Operating Instructions BA-003 Read and understand this manual before use. Keep this manual for future reference. CONFORMS TO UL STD.No.1017 Certified to CSA STD C22.2 No.243-10 For questions or concerns

More information

SPECIFICATIONS PART NAME

SPECIFICATIONS PART NAME SPECIFICATIONS MODEL High HEAT RATING Low FUEL TANK CAPACITY BURNING TIME DIMENSIONS(W x D x H) WEIGHT VOLTAGE / FREQUENCY ELECTRICAL CONSUMPTION LC-S27 9,900 BTU / 2.9 kw 2,900 BTU / 0.8 kw 4.0 lit. 14.2~

More information

Forced draught gas burner

Forced draught gas burner Installation, use and maintenance instructions Forced draught gas burner Code Model Type 3751982 GAS 3 519T80 291 (3) - 02/2010 DECLARATION Declaration of conformity in accordance with ISO / IEC 17050-1

More information

Operating Instructions

Operating Instructions Operating Instructions Typ TEKA CAREMASTER TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72

More information

HD 2.3/15 C Ed HD 3.0/20 C Ea

HD 2.3/15 C Ed HD 3.0/20 C Ea HD 2.3/15 C Ed HD 3.0/20 C Ea www.kaercher.com 5.961-971 2014000 05/06 3 IMPORTANT SAFETY INSTRUCTIONS WARNING! When using this product basic precautions should always be followed, including the following:

More information

Product Manual Glue Applicators MS 80 and MS 200

Product Manual Glue Applicators MS 80 and MS 200 Product Manual www.pakarte.com Glue Applicators MS 80 and MS 00 Translation from German to English Table of Contents Product Description General Safety Instructions Safety Measures to be taken during Operation

More information

PARAFFIN/DIESEL HEATER

PARAFFIN/DIESEL HEATER PARAFFIN/DIESEL HEATER MODEL NO: XR60 PART NO: 6931002 OPERATION & MAINTENANCE INSTRUCTIONS LS0813 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please

More information

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING FLAME115 INFRARED HEATER SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. TROUBLESHOOTING GUIDE 5. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER

More information

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and operating instructions. DK energy storage and DK energy buffer Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The

More information

3000W Pressure Washer RAC - HP006

3000W Pressure Washer RAC - HP006 3000W Pressure Washer RAC - HP006 Pressure Washer - Assemble and peration Assembly WANING: Before assembly ensure the on/off switch is off and the unit is not connected to the electric supply. Connect

More information

WHU WATER HEATING UNITS. GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS

WHU WATER HEATING UNITS.  GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS WHU WATER HEATING UNITS GENERAL MANUAL MODEL KEY WHU Water Heating Unit Maximum heating power, kw Max. water inflow pressure, bar Voltage options GENERAL INFORMATION WHU water heater, producing hot water

More information

Operating instructions

Operating instructions Operating instructions (Translation of the original operating instructions) Type TEKA FILTERCUBE-MV TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen

More information

Register and win! HD 1050 B HD 1050 DE HD 1050 B

Register and win!   HD 1050 B HD 1050 DE HD 1050 B HD 1050 B HD 1050 DE HD 1050 B Register and win! www.kaercher.com Deutsch 3 English 12 Français 21 Italiano 31 Nederlands 41 Español 50 Português 60 Dansk 70 Norsk 79 Svenska 88 Suomi 97 Ελληνικά 106 Türkçe

More information

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP InstructioNS for: INFRARED PARAFfIN / KEROSENE / diesel HEATER model No: ir20.v2 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these

More information

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN TTK 75 ECO EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport...05 Start-up...05

More information

DIESEL/PARAFFIN HEATERS

DIESEL/PARAFFIN HEATERS DIESEL/PARAFFIN HEATERS MODEL NO: XR80, XR110, XR160, XR210 PART NO: 6931004, 6931006, 6931008, 6931012 OPERATION & MAINTENANCE INSTRUCTIONS LS0814 INTRODUCTION Thank you for purchasing this CLARKE product.

More information

Operating instructions

Operating instructions Operating instructions for Winterhalter Gastronom dishwasher GS 502 and GS 515 Contents Page 1 Intended use... 1 2 Installation and commissioning... 1 3 Safety instructions... 2 4 Operating panel... 3

More information

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods

More information

3 in 1 Garden Vacuum 9255 Instructions for Use

3 in 1 Garden Vacuum 9255 Instructions for Use Leaf Blower-Vac/Patio Cleaner Technical Specifications Model GY 8113 Rated voltage 230V Rated frequency 50Hz Rated power consumption 3000W Mains fuse(delayed action) 13A Speed 15000 rpm Max. blower air

More information

BarAid 400. Installation and. Starting from Serial No.:

BarAid 400. Installation and. Starting from Serial No.: Glasswasher BarAid 400 Installation and operation Instructions Starting from Serial No.: 8649 1065 REV. 19.01.2009 DE 1618-A-01-09 Content Page 1 Important Notes... 4 2 Installation... 5 2.1 Location...

More information

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms

More information

PRO 2000i LOW LEVEL DEPOSITOR

PRO 2000i LOW LEVEL DEPOSITOR DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)

More information

The guarantee on this appliance is valid for 12 months from the first day of installation.

The guarantee on this appliance is valid for 12 months from the first day of installation. Users Manual Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This Users Manual provides detailed instructions and recommendations

More information

KB 3030B. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

KB 3030B. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them. KB 3030B Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. 5.961-751 F2012318 12/05 2 Dear Customer, Please read and comply with these

More information

K 2 Basic. Operating Instructions. Please read the operating instructions carefully before using the unit (05/17)

K 2 Basic. Operating Instructions. Please read the operating instructions carefully before using the unit (05/17) K 2 Basic Operating Instructions Please read the operating instructions carefully before using the unit. 59679030 (05/17) Contents Safety instructions............. 3 Description of the Appliance......

More information

User Guide Topax Hygiene System. S Booster MP44/MP66/MP88

User Guide Topax Hygiene System. S Booster MP44/MP66/MP88 User Guide Topax Hygiene System S Booster MP44/MP66/MP88 Vers. 1.0 01.01.2012 Contents 1. Preface... 3 1.0 Application... 3 1.1 Warnings... 3 1.2 Safety Instructions... 4 2. Standard Unit... 5 3. Description

More information

EHA Hoffmann International GmbH

EHA Hoffmann International GmbH EHA Hoffmann International GmbH User manual EHA-TRANSPRINT HP 2020 Machine-No.: Year: EHA Hoffmann International GmbH Michelsbergstraße 24 D-57080 Siegen/Germany Telephone: +49 271 39 32-0 Telefax: +49

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN AIRGOCLEAN 10 E EN OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN Table of contents Notes regarding the operating manual... 1 You can download the current version of the operating manual and

More information

RX525 Electric Pressure Washer s Original instructions WARNING:

RX525 Electric Pressure Washer s Original instructions WARNING: RX525 Electric Pressure Washer s Operating Instructions Original instructions WARNING: Do not use the machine without reading the instruction sheet. APPLICATION The Wilks-USA 525i Electric Pressure Washer

More information

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN TTK 75 E EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport... 05 Operation...

More information

DAIKIN ROOM AIR CONDITIONER. Operation Manual

DAIKIN ROOM AIR CONDITIONER. Operation Manual DAIKIN ROOM AIR CONDITIONER Operation Manual FDXM25F2V1B FDXM50F2V1B FDXM35F2V1B FDXM60F2V1B CONTENTS READ BEFORE OPERATION Safety precautions... 2 Names of parts... 4 CARE Care and Cleaning... 6 TROUBLE

More information

User Instruction Manual

User Instruction Manual User Instruction Manual Mulled Wine Heater Please read and keep these instructions You will need: -32 amp plug socket -Temperature thermometer These instructions cover the Mulled Wine Heater Mulled Wine

More information

Mod. ANBR9..G. CR DOC. NO. GAS-HEATED TILTING BRATT PAN. INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT, USE AND MAINTENANCE...

Mod. ANBR9..G. CR DOC. NO. GAS-HEATED TILTING BRATT PAN. INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT, USE AND MAINTENANCE... -HEATED TILTING BRATT PAN Mod. ANBR9..G. INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT, USE AND MAINTENANCE...page 2-5 APPENDIX....pagina 6-7 Read the manual thoroughly and keep it in a safe place throughout

More information

Important - Please read these instructions fully before operating or maintaining. Warning Symbols...3. General Safety...4. Personal Safety...

Important - Please read these instructions fully before operating or maintaining. Warning Symbols...3. General Safety...4. Personal Safety... Contents Safety Information Important - Please read these instructions fully before operating or maintaining Safety Information...3 Warning Symbols...3 General Safety...4 Personal Safety...4 Operating

More information

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro 2006/01 Content Important Information 1. Notes... 3 1.1 CE - Labeling... 3 1.2

More information

infrared paraffin / kerosene / diesel heater

infrared paraffin / kerosene / diesel heater instructions for infrared paraffin / kerosene / diesel heater model no: IR20.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these

More information

Propane Heater REMKO PGM 30 REMKO PGM 60

Propane Heater REMKO PGM 30 REMKO PGM 60 Propane Heater REMKO PGM 30 REMKO PGM 60 Operation Technology Spare Parts Edition GB L07 REMKO strong as a bear. Operating instructions Make sure to read these instructions carefully before starting/using

More information

Operating Instructions

Operating Instructions Operating Instructions P4 Pellet 8-60 Read and follow the operating instructions and safety information. Subject to technical change. July 2009 Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestrasse

More information

OPERATING & MAINTENANCE MANUAL DC10 DC15 DC25 DC40 DC45

OPERATING & MAINTENANCE MANUAL DC10 DC15 DC25 DC40 DC45 OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS DC10 DC15 DC25 DC40 DC45 Made By: NOT FOR DOMESTIC USE SPACE HEATING ONLY Spitwater Australia Pty Ltd 953 Metry St., North

More information

User Instruction Manual

User Instruction Manual User Instruction Manual Counter Top Convection Oven Please read and keep these instructions These instructions cover the Burco counter top convection oven model CTCO01, SKU 444440542 CTCO01 SKU 444440542

More information