ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features
|
|
- Clinton McCarthy
- 5 years ago
- Views:
Transcription
1 Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data... 6 Heat Kit Data... Wiring Diagram... Accessories... Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting track for quick repositioning Optimized for use with R-0A refrigerant Cabinet air leakage less than.0% at.0 inch HO when tested in accordance with ASHRAE standard Cabinet air leakage less than.% at 0. inch HO when tested in accordance with ASHRAE standard kw kw electric heater kits Horizontal or vertical configuration capabilities Rigid SmartFrame cabinet depth for easier attic access DecaBDE-free thermoplastic drain pan with secondary drain connections Screw-less sides and back helps to reduce condensation when installed in humid locations Foil-faced insulation covers the internal casing to reduce cabinet condensation Galvanized, leather grain-embossed finish Glue-less cabinet insulation retention Tool-less filter access AHRI certified; E listed * Complete warranty details available from your local dealer or at To receive the 0-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-G / Supersedes /
2 Nomenclature A S P T C AA,6 0, Brand Engineering * A - Single- Piece Air Handler Major/ Minor Revisions Unit Application C - Ceiling Mount PSC Motor R - Multi- Position PSC Motor S - Multi- Position EEM Motor W - Wall Mount PSC Motor Cabinet Finish U - Unpainted P - Painted N - Uncased *Not used for inventory management Refrigerant Compatability = R- 0A Electrical - 0/0 V, Phase, 60 Hz Nominal Width B - ½ Wide C - Wide D - ½ Wide Expansion Device F - Flowrator Nominal Capacity Range T - Expansion Valve = Tons = ½ Tons 0 = ½ Tons = Tons 6 = Tons 60 = Tons 6 = Tons HKS X 0 X A AA Unit Type Major & Minor Revisions HKS - AH Heater Kit Phase Circuit Breaker A VAC / Ø D VAC / Ø X - - No circuit breaker B VAC / Ø E VAC / Ø C - - Circuit Breaker C - - 0/0 VAC / Ø F - - 0/0 VAC / Ø G VAC / Ø kw kw - -. kw Cabinet Size (MAX) kw - -.kw w/0f limit C - - C Cabinet kW kw w/0f limit D - - D Cabinet kW kw X - - All Cabinet Sizes kw SS-G
3 Product Specifications B* B* B* C* C* C* D* D* 6D* Nominal Ratings Cooling (Btu/h),000,000 0,000 6,000,000 60,000,000,000 60,000 Blower Diameter ½" ½" ½" 0⅝" 0⅝" 0⅝" 0⅝" ¹⁵ ₁₆" ¹⁵ ₁₆" Width 6" 6" 6" " 0⅝" 0⅝" 0⅝" 0⅝" 0⅝" Coil Connections Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" Coil Drain Connect (FPT) ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" Electrical Data Voltage 0 / 0 0 / 0 0 / 0 0 / 0 0 / 0 0 / 0 0 / 0 0 / 0 0 / 0 Minimum Circuit Ampacity. /.. /..6 /.6.6 /.6.6 /.6. /..6 /.6.6 /.6.6 /.6 Max. Overcurrent Device (Amps) / / / / / / / / / Minimum VAC Maximum VAC Blower Motor Full Load Amps (A) Horsepower (HP) ¾ ¾ ¾ ¾ ¾ ¾ Ship Weight (Lbs.) *Airflow static Note: Assumes dry coil; SCFM correction for wet coil = % (0V / 0V) SS-G
4 Dimensions.0" (. cm).6" (. cm)." (.6 cm) ".0" (. cm)." (. cm)." (. cm)." (. cm)." (. cm)." DRAIN PORT DETAIL." (.0 cm) C B." (.0 cm)." (. cm)." (.6 cm)." (.0 cm)." (.0 cm) PLASTIC EAKER COVER." (.6 cm) LOGO LOCATION." (.cm) SUCTION TUBE LIQUID LINE A G INLET TUBE SEE DRAIN PORT DETAIL H E D." (. cm) F INLET (FRONT VIEW)." (. cm) " (. cm)." (. cm) INLET (RIGHT SIDE VIEW)." (.0 cm) Model A" B" C" D" E" F" G" H" B* 6⅜ ½ ¼ /6 ⅛ ⅝ B* /6 6⅜ ½ /6 0½ /6 ⅛ ⅝ B* /6 6⅜ ½ /6 0½ /6 ⅛ ⅝ C* /6 ⅞ /6 ⅝ /6 0 /6 6⅞ C* /6 ⅞ /6 ⅝ /6 0 /6 6⅞ C* /6 ⅞ /6 ⅝ /6 0 /6 6⅞ D* /6 /6 ½ ½ /6 /6 ⅝ 6⅞ D* /6 ½ 6⅛ ⅞ /6 ⅝ ⅛ 6D /6 ½ 6⅛ ⅞ /6 ⅝ ⅛ SS-G
5 Dimensions (Cont.) Model A" B" C" D" E" F" G" H" 6D /6 ½ 6⅛ ⅞ /6 ⅝ ⅛ SS-G
6 Airflow Data Model BAA BAA BAA CAA CAA DAA DAA CAA 6DAA Speed Tap Static Pressure (in w.c) ,,0,00,,,0,0,0, , ,0,6,0,0,,0,,,0, ,0,0,06,0 0 0,0,00,60,0,0,00,00 0,,00,,0,0,0,,0,,0,,,0,,0,,0, ,,0,0, ,,0,,0,0,0,00 6 0,,0,,0,,,,0,0,6,,0,0,0,0,6,0, ,00,00, ,0,60,0,0, ,,0,6,0,,,0,0,0,,0,,00,60,0,,0,0,0, ,0,6,0,00, ,,0,0,0,,00,00 0 0,6,0,0,,,0,0,,0,0,60,6,0,0,0,,0,,,,0,0,6,00,0,0 0,0,,0,0,0,,,,0,60,600,0,,,0,60,0,,00,6,,60,6,0,0,6,0,,60,0,0,00,000,0,0,6,0,0,,,,0,0,00,060,,00,6,0,0,0,,00,0,60,6,6,,,0,0,0,0,0,,0,60,60,,,0,0,0,,,00,60,0,0,0,0,,,0,0,,60,0,00,00,,6,6,,,,00,60,,0,,,0,,60,6,,00,,0,00,0,000,0,,0,0,0,0,6,0,,6,0,00,00 Notes The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. Use the CFM adjustment factors of. for horizontal left,. for horizontal right &.6 for downflow orientations. Assumes dry coil with filter in place. All models are shipped from the factory with the speed tap set on T. Assumes dry coil; SCFM correction for wet coil = % All models are shipped from the factory with the speed tap set on T. 6 SS-G
7 Heat Kit Data Model Circuit Circuit Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² BAA 0/0./. / HKS*0XC* 0./. / 0/ HKS*0XC*./0.0 / 0/ HKS*06XC*.6/.0 / / HKS*0XC*./. / / HKS*0XC*.6/0.0 /6 0/ BAA 0/0./. / HKS*0XC* 0./. / 0/ HKS*0XC*./0 / 0/ HKS*06XC*./ / / HKS*0XC*./. / / HKS*0XC*./0 /6 0/ HKS**#*./0 /6 0/60 /0 / / / 0/0 BAA 0/0.6/.6 / HKS*0XC* 0./. / 0/ HKS*0XC*./0 / 0/ HKS*06XC*./ / / HKS*0XC*./. / / HKS*0XC*./0 /6 0/ HKS**#*./0 /6 0/60./0 / / / 0/0 CAA 0/0.6/.6 / HKS*0XC* 0./. / 0/ HKS*0XC*./0 / 0/ HKS*06XC*./ / / HKS*0XC*./. / / HKS*0XC*./0 /6 0/ HKS**#*./0 /6 0/60./0 / / / 0/0 HKSCC*#*./0 /6 0/60./0 /0 /0 /06 00/0 HKSC*XF* 0/0.6/.6 / 0/.6 / 0/ CAA 0/0.6/.6 / HKS*0XC* 0./. / 0/ HKS*0XC*./0 / 0/ HKS*06XC*./ / / HKS*0XC*./. / / HKS*0XC*./0 /6 0/ HKS**#*./0 /6 0/60./0 / / / 0/0 HKSCC*#*./0 /6 0/60./0 /0 /0 /06 00/0 HKSC*XF* 0/0.6/.6 / 0/.6 / 0/ ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X. ² Maximum Overcurrent Protection =. X Motor Amps + Heater Amps ^ Circuit : Single-phase for Air Handlers Circuit : Three-phase for HKR Heater Kits * Revision level that may or may not be designated C = Circuit Breaker Option --- indicates Not Required Heating kw Correction Factor Supply Voltage Correction Factor Multiply the 0-volt heating capacity by correction factors. SS-G
8 Heat Kit Data (cont.) Model Circuit Circuit Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² CAA 0.0/.0.0./. / HKS*0XC* 0./. / / HKS*0XC*./0 0/ 0/ HKS*06XC*./ / / HKS*0XC*./. /0 / HKS*0XC*./0 / 60/ HKS**#*./0 / 60/60./0 / / / 0/0 HKSCC*#*./0 / 60/60./0 /0 /0 /0 00/0 HKSC*XF* 0.0/0.0./. / 0/.6 / 0/ DAA 0/0.6/.6 / HKS*0XC* 0./. / 0/ HKS*0XC*./0 / 0/ HKS*06XC*./ / / HKS*0XC*./. / / HKS*0XC*./0 /6 0/ HKS**#*./0 /6 0/60./0 / / / 0/0 HKSC0D#C*./0 /6 0/60./0 /0 /0 /06 00/0 HKSC*XF* 0/0.6/.6 / 0/.6 / 0/ HKS*0XF* 0/0.6/.6 /./. / 0/ DAA 0/0.6/.6 / HKS*0XC* 0./. / / HKS*0XC*./0 0./ / HKS*06XC*./ 6/0 0/ HKS*0XC*./. /0. / HKS*0XC*./0 / 60/ HKSC*#*./0 / 60/60./0.0 / / / 0/0 HKSC0D#*./0 / 60/60./0.0 /0 /0 /0 00/0 HKS*XF* 0/0.6/.6 / 0/.6 / 0/ HKS*0XF* 0/0.6/.6 /./. / 0/ HKSCDC* /60 / 0/0 /0 /0 /0 / /0 6DAA 0/0.6/.6 / HKS*0XC* 0./. / / HKS*0XC*./0 0./ / HKS*06XC*./ 6/0 0/ HKS*0XC*./. /0. / HKS*0XC*./0 / 60/ HKSC*#*./0 / 60/60./0.0 / / / 0/0 HKSC0D#*./0 / 60/60./0.0 /0 /0 /0 00/0 HKS*XF* 0/0.6/.6 / 0/.6 / 0/ HKS*0XF* 0/0.6/.6 /./. / 0/ HKSCDC* /60 / 0/0 /0 /0 /0 / /0 ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X. ² Maximum Overcurrent Protection =. X Motor Amps + Heater Amps ^ Circuit : Single-phase for Air Handlers Circuit : Three-phase for HKR Heater Kits * Revision level that may or may not be designated C = Circuit Breaker Option --- indicates Not Required Heating kw Correction Factor Supply Voltage Correction Factor Multiply the 0-volt heating capacity by correction factors. SS-G
9 R HTR HTR HTR R M M HTR HTR HTR M M R R HTR HTR HTR HTR M M R M M6 M M R 6 ONE () ELEMENT ROWS TWO () ELEMENT ROWS THREE () ELEMENT ROWS FOUR () ELEMENT ROWS NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE BOX PROVIDED ABOVE.MARK ACCOING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. PLM 0/0 VOLTS EM LGN PLM WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE FUSE HOLDER (OPTIONAL) NOTES: TR V 6 P L M SEE NOTE B R C G WW Y Y O DH A CR EM C COMPONENT CODE CR CONTROL RELAY EM EVAPORATOR MOTOR FUSE LINK HTR HEAT ELEMENTS PLM COLOR CODE ACK RED YELLOW UE EEN RPLE OWN ITE FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR R RELAY TB TERMINAL BOA TR TRANSFORMER THERMAL LIMIT COPPER POWER SUPPLY (USE RATING PLATE) USE MIN. C FIELD WIRE IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. ) RED WIRES TO BE ON TRANSFORMER TERMINAL "" FOR 0 VOLTS AND ON TERMINAL "" FOR 0 VOLTS. ) SEE COMPLETE WIRING DIAAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. ) CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT RPLE WIRE FROM TERMINAL OF CR RELAY TO APPROPRIATE TAP AT TB ) OWN AND ITE WIRES ARE USED FOR HEAT KITS ONLY. ) FUSE: A, 0V, AG CARTRIDGE FUSE. 00A0006-B Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death C USE COPPER WIRE EQUIPMENT OUND PLM G SEE NOTE R C G W W Y Y O DH 6 0 TR 6 or CR or or FUSE HOLDER (OPTIONAL) OR EM C L G N Air Handler Wiring Diagram CR SEE NOTE SEE NOTE ALTERNATE HEAT RELAY A B V ALTERNATE HEAT RELAY NOTE: The five element, kw heater kit is not shown above. SS-G
10 Five-Element Heater Kit Wiring Diagram HTR COMPONENT CODE COLOR CODE HTR HTR HTR HTR M M6 M M M M 0 M PC R PC = PIN CONNECTOR HTR = HEATER ELEMENT = THERMAL LMT RS = RELAY/SEQUENCER TB = TERMINAL OCK CB = CIRCUIT EAKER CC = CONTACTOR = FUSE LINK EM = EVAPORATOR MOTOR EBTDR = ELEC. OWER TIME DELAY RC = RUN CAPACITOR TR = TRANSFORMER SR = STRAIN RELIEF WIRING CODE: HIGH VOLTAGE LOW VOLTAGE = ACK = UE = OWN = EEN OR = ORANGE PK = PINK = RPLE = RED = ITE = YELLOW R R 6 NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER / HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. FIVE () ELEMENT ROWS CB CB CB NOTE:- THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION CB L L 00M00-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 0 SS-G
11 Three-Phase Heater Kit Wiring Diagram NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. PC TB CIRCUIT PH 0-0V HTR TR HTR L GND L CIRCUIT PH. 0-0V CC R T T T HTR RS M M 6 PK EBTDR NO K XFMR-R XFMR-C COM K C NC SPEEDUP SR RC EM NOTE:- THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION PK RC AR POWER SUPPLY (CIRCUIT ) TR EM VOLT 0/0 VOLTS LOW HIGH C NC NO EBTDR COM EBTDR PC 6 W W W HKR POWER SUPPLY (CIRCUIT ) L T T T HTR HTR M HTR M CC RS HEATER CONTROL COMPONENT CODE HTR HEAT ELEMENT EM EVAPORATOR MOTOR EBTDR ELEC. OWER TIME DELAY RELAY RS RELAY/SEQUENCER RC RUN CAPACITOR THERMAL LIMIT TR TRANSFORMER TB TERMINAL OCK CC CONTACTOR PC -PIN CONNECTOR SR STRAIN RELIEF FUSE LINK CB CIRCUIT EAKER WIRING CODE HIGH VOLTAGE LOW VOLTAGE COLOR CODE ACK UE OWN EEN OR ORANGE PK PINK RPLE RED ITE YELLOW 00M00-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SS-G
12 Accessories Downflow Insulation Kit DFK-B DFK-C DFK-D B** 0C** D** 6C** C** C** D** 60D** 6D** Filters Chassis Part # Size B ALFH60E 6.0 x 0.0 C ALFH0E. x 0.0 D ALFH0E.0 x 0.0 Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 0 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA. SS-G
ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...
More informationASUF Series. Multi-Position. Air Handler 1½ to 5 Tons
ASUF Series Multi-Position Multi-Speed ECM Based Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting
More informationARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow
More informationARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor
Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat Kit Data...6 Wiring Diagram... Accessories... Product Features Internal factory-installed thermal
More informationASUF Series. Multi-Position. Air Handler 1½ to 5 Tons
Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting track for quick repositioning Optimized for
More informationARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor
Contents Nomenclature... 2 Accessories... 2... 3 Dimensions... 4 Airflow Data... 5 Heat Kit Data... 6 Wiring Diagram... 8 Series Product Features Internal factory-installed thermal expansion valves for
More informationAVPTC Multi-Position, Internal Txv
Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat
More informationAVPTC Multi-Position, Internal Txv
Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5
More informationMBR. Multi-Position. Modular Blower
M Product Features Direct drive, multi-speed PSC blower motor kw 1 kw electric heat kits Blower section usable as electric heater Horizontal or vertical configuration capabilities 1" depth for easier attic
More informationMBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features
M Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow Data... 5 Heat
More informationMBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features
MBVC Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data...
More informationAVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.
Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...
More informationMBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor. Contents. Product Features
M Multi-Position, Multi-Speed Modular Blower With PSC Motor Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow Data... 5 Heat Kit Data...
More informationASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features
ASUF Series Multi-Position, Multi-Speed EM-Based Air Handler ½ to Tons ontents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Heat Kit Data... Wiring Diagram...
More informationAVPTC Multi-Position, Internal Txv
Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor ComfortNet Communicating System compatible Auto configuration
More informationMBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features
Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible Contents MBVC Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data... Heat Kit Data...
More informationDVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV
DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3
More informationTECHNICAL MANUAL. ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers
TECHNICAL MANUAL AL ARPT**4**, ARUF**4**, ASPT**4**, ASUF**4** Air Handlers Refer to Service Manual RS600006 for installation, operation & troubleshooting information. All safety information must be followed
More informationDVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons
DVPEC Multi-Position, Variable-Speed air handler Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow
More informationAVPTC. Air Handler 1½ to 5 Tons
Multi-Position, Variable-Speed Air Handler ½ to 5 Tons Standard Features Compatible with the ComfortNet Communicating System family of products Maximum four low-voltage wires required for operation in
More informationAVPTC. Air Handlers 1½ to 5 Tons
Multi-Position, Variable-Speed Air Handlers ½ to Tons Standard Features Compatible with the ComfortNet Communicating System family of products R-0A refrigerant-compatible Factory-installed thermal expansion
More informationACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons
ACNF Series Ceiling-Mounted Air Handlers 1½ to 2½ Tons Contents Nomenclature...2 Heat Kit Data...2 Product Specifications...3 Dimensions...5 Airflow Data...5 Wiring Diagram...6 Accessories...8 Features
More informationACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons
ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 Check flowrater for heat pump and cooling-only applications All-aluminun tube/aluminum
More informationAEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7
Multi-Position, Variable-Speed Air Handlers 1½ to 5 Tons Standard Features Suitable for use with R-410A and R-22 refrigerants Check flowrater expansion device for cooling and heat pump applications Variable-speed
More informationADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW
ADPF THREE-SPEED AIR HANDLER The ADPF Dedicated Downfl ow Three-Speed Air Handler is suitable for use with refrigerants R-410A and R-22. The unit features a check flowrater expansion device and may be
More informationACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons
ANF Series eiling-mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 heck flowrater for heat pump and cooling-only applications All-Aluminum tube/aluminum
More informationAEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton
AEPT SERIES Multi-Position Air Handler 2 to 5 Ton The AEPT multi-position air handler is approved for modular homes and may be installed in a utility room, closet, aclove, basement or attic. Standard Features
More informationPRODUCT SPECIFICATIONS
16 SEER / R-410A HIGH-EFFICIENCY 2- TO 5-TON SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY: 24,000 BTU/H TO 57,000 BTU/H The Goodman 16 SEER Air Conditioner uses the environmentally friendly refrigerant
More information80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h
Series 80% AFUE Multi-Position, Dual$aver Multi-Speed Gas Furnace Heating Input: 70,000 115,000 BTU/h Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve that allows installer to
More informationBosch BVA Series Air Handler
Bosch BVA Series Air Handler 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BVA Product Specifications Data subject to change 12.2016 Bosch Thermotechnology Corp. Product Specifications
More informationAEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton
AEPT SERIES Multi-Position, Variable-Speed High-Efficiency Air Handler 2 and 5 Ton The AEPT air handler is compact for versatile upflow/downflow or horizontal multi-position installations and may be located
More informationMBR. Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h
MB Cooling Capacity: 18,000-60,000 BTU/h Multi-Speed Modular Blowers Standard Features Multi-speed PSC blower motor Cooling or heat pump applications: upflow, downflow, and horizontal applications Control
More informationPC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]
PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed
More informationGMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace
Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage
More informationADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h
ADSH8 Heating Input: 40,000 100,000 BTU/h Two-Stage Convertible Multi-Speed Gas Furnace 80% AFUE Standard Features Two-stage convertible gas valve automatically adjusts to high or low stage Durable SureStart
More informationDM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h
Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...
More informationGMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h
/ Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Heating Input: 40,000 120,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Specifications...7 Wiring Diagram...10
More informationGMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h
/ Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10
More informationGME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h
80% AFUE Multi-Position, TwinComfort Multi-Speed Gas Furnace Heating Input: 60,000 100,000 BTU/h Standard Features Patented dual-diameter tubular heat exchanger Two-stage gas valve that allows installer
More informationMBR. Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h
MB Multi-Speed Modular Blowers Cooling Capacity: 18,000-60,000 BTU/h Standard Features Multi-speed PSC blower motor Cooling or heat pump applications: upflow, downflow, and horizontal applications Control
More informationGMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
/ Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10
More informationGMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
/ Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10
More informationBCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY
PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access
More informationWAHL A Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Number Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0
More informationmaintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.
AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the
More informationBosch BVA Series Air Handler
Bosch BVA Series Air Handler --- Ton Capacity R0A Product Specifications Product Specifications BVA Series Air Handler --- Ton Capacity R0A Air Handler Features Multi-speed ECM blower motor. Factory-installed
More informationVERTICAL MOUNT AIR HANDLERS
VERTICAL MOUNT AIR HANDLERS INSTALLATION INSTRUCTIONS 2005-2009 Goodman Manufacturing Company, L.P. 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com -or- www.amana-hac.com P/N: IO-281J
More information157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL
ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering device
More informationFEM4X. Product Specifications FAN COILS /14/15
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS 1 1/2 thru 5 tons Available for environmentally sound R 410A systems Factory installed TXV metering device Sweat connections Aluminum Tube, Aluminum Fin Evaporator
More informationSubmittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:
Submittal 5 Ton Convertible Air Handler TEM3A0C60S51SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationProduct Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:
DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed
More informationProduct Data. Convertible Air Handlers 1 1/2 5Ton
Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SB TEM4A0B24S21SB TEM4A0B30S31SB TEM4A0B36S31SB TEM4A0C37S31SB TEM4A0C42S41SB TEM4A0C48S41SB TEM4A0C60S51SB The TEM4 series air handler is designed
More informationMX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat
SG-MAH-08 April 2016 MX Series Indoor Modular Blowers Electric Heat, Hot Heat, or No Heat Specification Guide Contents...Pa Page Standard Features... 2 Physical Data... 2 Blower Performance... 3 Nomenclature...
More informationREM4P, REM4X. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT REM4P, REM4X Product Specifications FAN COILS ALL MODELS 2 thru 5 tons Available for environmentally sound R 410A systems Factory installed piston metering device with
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw
More informationAIR HANDLERS AIR HANDLERS
FORM NO. H11-33 REV. 1 Supersedes Form No. H11-33 AIR HANDLERS AIR HANDLERS RHBL- Efficiency X-13 (ECM) featuring Industry Standard R-410A Refrigerant RHAL- Standard Efficiency PSC featuring Industry Standard
More information49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1½ thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed High Efficiency, 3
More information49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)
ENVIRONMENTALLY SOUND REFRIGERANT FXM4X Product Specifications FAN COILS FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Sweat
More informationVariable Speed Convertible Air Handler 5 Ton
Submittal Variable Speed Convertible Air Handler 5 Ton TEM6A0C60H51S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace
More informationTECHNICAL SPECIFICATIONS B6VMMX
TECHNICAL SPECIFICATIONS BVMM Series Air Handler with TV, -, Btuh (Heat Pump & Air Conditioner) R-4A Refrigerant The BVMM Series of air handlers, when combined with our heat pump or air conditioner, offers
More informationSubmittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:
Submittal 1 1/2 Ton Convertible Air Handler SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationSubmittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:
Submittal 2 Ton Convertible Air Handler TEM3A0B24S21SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationProduct Data. Convertible Air Handlers 1 1/2 5Ton
Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SA TEM4A0B24S21SA TEM4A0B30S31SA TEM4A0C36S41SA TEM4A0C42S41SA TEM4A0C48S41SA TEM4A0C60S51SA The TEM4 series air handler is designed for installation
More informationAR SERIES COMMERCIAL AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS
AR SERIES COMMERCIAL AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS NOTE: AR models are suitable for Upflow and Horizontal Installations only. Do not use for Downflow Installations RECOGNIZE THIS SYMBOL
More informationFXM4X. Product Specifications FAN COILS FXM4X
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Copper
More informationTECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES
TP TECH GUIDE TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP 1200-2000 CFM BLOWERS 3-5 TON COILS OPTIONAL ELECTRIC HEATERS ISO 9001 Certified
More informationDimensions H x W x D in. (mm)
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Model Series Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,
More informationGMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH
GMS95 GAS $AVER 95% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH 95% AFUE s Qualify for a $150 Tax Credit Standard Features Corrosion-resistant, aluminized-steel
More informationFan Coils & Air Handlers Product Catalog
Fan Coils & Air Handlers Product Catalog 120V/240V motors PSC and ECM high efficiency constant torque motors Heavy-gauge, galvanized steel construction High efficiency rifled copper tubes/enhanced aluminum
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...
More informationIMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2
Service Literature Corp. 0527 L10 Revised May 2011 CB26UH and CBX26UH Series Table of Contents CB26UH CBX26UH Model Number Information................... 2 Specifications / Electrical Data................
More informationREPAIR PARTS. HKS Heater Kits
REPAIR PARTS HKS Heater Kits HKSC05XCAA HKSC08XCAA HKSC10XCAA HKSC15XAAA HKSC15XBAA HKSC19CAAA HKSC19CBAA HKSC20DAAA HKSC20DBAA HKSX03XCAA HKSX05XCAA HKSX06XCAA HKSX08XCAA HKSX10XCAA This manual is to
More informationTECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36
TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 Due to continuous product improvement, specifications are
More informationProduct Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:
PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230
More informationPRODUCT SPECIFICATIONS
CPLJ SERIES SEER SPLIT SYSTEM HEAT PUMP COOLING CAPACITY: 6, TO 6, BTU/H HEATING CAPACITY: 6, TO 6, BTU/H ½ TO TON The CPLJ features an attractive louvered metal guard that protect the coil from damage
More informationProduct Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:
DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230
More informationRheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Rheem Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check
More informationREPAIR PARTS. HKS Heater Kits. This manual is to be used by qualified technicians only. This manual replaces RP-704A.
REPAIR PARTS HKS Heater Kits HKSC05XCAA HKSC08XCAA HKSC10XCAA HKSC15XAAA HKSC15XBAA HKSC15XBAB HKSC15XFAA HKSC19CAAA HKSC19CBAA HKSC19CBAB HKSC20DAAA HKSC20DBAA HKSC20DBAB HKSC20XFAA HKSC25DCAA HKSX03XCAA
More informationHIGH EFFICIENCY AIR HANDLER
FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile
More informationRuud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Ruud Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check
More informationREPAIR PARTS. HKR / HKA/ HKP Heater Kits
HKR / HKA/ HKP Heater Kits HKA-15CA HKA-20CA HKP-15CA HKP-20CA HKR-03 HKR-03A HKR-05 HKR-05A HKR-05C HKR-05CA HKR-05CB HKR-06 HKR-06A HKR-08 HKR-08A HKR-08C HKR-08CA HKR-08CB HKR-10 HKR-10A HKR-10C HKR-10CA
More informationProduct Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil
FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil
More informationP8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that
More information13 GEP A L P - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800
More informationVariable Speed Convertible Air Handler 4 Ton
Submittal Variable Speed Convertible Air Handler 4 Ton TEM6A0D48H41S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These
More informationRheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Rheem Air Handler RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RHAL- Series PSC Motor Efficiencies up to 14. SEER Front or Bottom Return Flow Check Piston for cooling or heat pump
More informationRuud Standard Efficiency Air Handler
Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.
More informationRGE 13 A T - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE
More informationGMS9/GCS9 SERIES 93% AFUE
GMS9/GCS9 SERIES 93% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH The GMS9/GCS9 single-stage, multi-speed gas furnaces offer installation versatility.
More informationDEDICATED VERTICAL/WALL MOUNT
WCW-Chilled Water Cooling Electric or Hot Water Heating Description: The B/S/H, & WCW air handlers with electric or hot water heating are designed for recessed mounting in a wall, hanging on the wall,
More informationMERIT SERIES Up Flow / Horizontal
A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional
More informationCWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH
CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal
More informationJS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity
TECHNICAL SPECIFICATIONS JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System 1.5-5 Ton Capacity The JS5BD Series of air conditioners offers exceptional performance. The unit,
More informationDH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil
DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS OPTIONAL ACCESSORIES Two Row Hot Water Coil MAGIC AIRE DH SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED
More informationPRODUCT CATALOG. Aspen Manufacturing - Evaporator coils - Air Handlers - Manufactured Home Products - Light Commercial Coils
PRODUCT CATALOG Aspen Manufacturing - Evaporator coils - Air Handlers - Manufactured Home Products - Light Commercial Coils Aspen Background: Aspen, headquartered in Humble, Texas, is one of the largest
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS 23 SEER Residential System Indoor Section M1200 Product Line PAH2VM Series Variable Speed Air Handler C5 Series Residential Indoor Coils with EXV 2 M1200 12 YEAR ALL PARTS LIMITED
More informationProduct Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )
(N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS
More information