AIR CURTAIN PHV SURFACE MOUNTED RANGE
|
|
- Samson Paul
- 5 years ago
- Views:
Transcription
1 AIR CURTAI PHV SURFAC MOUTD RAG ISTALLATIO, OPRATIO AD MAITAC ISTRUCTIOS nglish T UK (v9) Page
2 COTTS Page COTTS... LCTRICAL SAFTY... SPCIFICATIOS.... ITRODUCTIO DLIVRY COTTS TOOLS RQUIRD ISTALLATIO ACCSS FOR LCTRICAL COCTIO RMOT COTROL ISTALLATIO RMOT COTROL STTIGS XTRAL COTROLS MULTIPL AIR CURTAI SYSTMS.... SYSTM COFIGURATIO.... FA SPD SLCTIO RMOT COTROL OPRATIO COMMISSIOIG TH SYSTM SIG OFF FAULT CODITIOS SRVIC & MAITAC WARRATY... 8 APPDIX Dimensions of PHV Surface Mounted Air Curtain... 9 APPDIX A WIRIG DIAGRAM PHV APPDIX B WIRIG DIAGRAM PHV APPDIX C WIRIG DIAGRAM PHV APPDIX D WIRIG DIAGRAM PHV000W, PHV500W and PHV000W... APPDIX WIRIG DIAGRAM PHV000A, PHV500A and PHV000A.... DCLARATIO OF COFORMITY... 5 T UK (v9) Page
3 LCTRICAL SAFTY lectrical Supply and Wiring to the Air Curtain All electrical wiring and connections MUST be carried out by a competent qualified electrician in accordance with the latest edition of I wiring regulations and local statutory regulations if applicable. A phase or phase local isolator having a contact separation of at least mm on all poles must be fitted in the electrical supply to the air curtain and located in an accessible position adjacent to the unit. The appliance must be connected by cables having an appropriate heat resistant temperature rating. All supply cables, circuit breakers and other electrical installation equipment must be correctly sized for the air curtain model being installed; see Section : Specifications. Models operating on a phase electrical supply - see Section : Specifications - require a neutral connection (~). A 5mm size cable gland or conduit connector of IP rating or above should be used for the lectrical Supply into the air curtain. See Wiring Diagrams for connecting electrical supply and control cables to the air curtain. The air curtain must be earthed. SPCIFICATIOS Air Curtain Model o lectrical Supply (V/ph/Hz) Rated lectrical Power Input (kw) Rated Current per phase (A) Heat Output [Low/High] (kw) Weight (kg) PHV000A 0// PHV500A 0// PHV000A 0// PHV000W 0// /.0 5 PHV500W 0// / PHV000W 0// /.0 6 PHV000 00// /.0 PHV500 00// / PHV000 00// /.0 6 Table T UK (v9) Page
4 . ITRODUCTIO stablished in the 960s, Thermoscreens is a leading air curtain manufacturer that exports to over 60 countries worldwide. As with all our products, the PHV range of air curtains is designed with energy efficiency in mind. PHV models suffixed, W or A are designed to be surface mounted inside a building and located horizontally over a doorway. They must not be installed on the outside of a building or built into a cabinet or recessed in any way. Please complete the following details for your reference: Date of Purchase Place of Purchase Serial umber Proof of purchase is required to make a claim under warranty. Thermoscreens Ltd St. Mary s Road uneaton Warwickshire ngland CV 5AU mail: sales@thermoscreens.com Tel: + (0) Fax: + (0) T UK (v9) Page
5 5. DLIVRY COTTS The following items are supplied in the box at delivery. OT: If any parts are missing or damaged contact your place of purchase. PHV Surface Mounted Air Curtain copower Remote Control (for lectric and Water Heated units) Remote Control Switch (for Ambient units) ote: nd caps are supplied loose to be fitted during installation Supplied with 6m RJ Control Cable Wall Brackets and M6 Fixing Bolts -port control valve (for water heated units) Outdoor Air Thermostat (Optional supplied by Installer) brackets for PHV500/000 units Fitted in pipework to air curtain by installer Used for simple weather compensation control (disables heating on a warmer day) 6. TOOLS RQUIRD The following tools are required for installation: Flat blade screwdrivers Pozi head screwdrivers 0mm spanner Adjustable spanner lectric drill Ladders Appropriate lifting equipment T UK (v9) Page 5
6 7. ISTALLATIO The air curtain is designed to be located horizontally over a doorway. It must not be installed outside of the building. 7. Location Mount the air curtain above and as close to the doorway as possible, with: 00mm the discharge grille not more than m above floor level at least 00mm clearance (air gap) above electric/water heated air curtains, see Fig Beware of doorway top edges, structural beams, door opening/closure devices, etc., which may interfere with the air stream and affect the location of the unit. Fig 000mm OT: For the air curtain to work well the width of the open doorway Fig should be less than the length A of the air curtain, see Appendix. 7. Wall Fixing OT: Use suitable wall fixing bolts (not supplied) to fix the unit to the wall, taking into account the type of wall and the weight of the unit (see section : Specifications). Step Step Step Step Step 5 Bolt all wall brackets to the rear face of the unit as shown in Fig, using the M6 fixing bolts supplied. Drill fixing points in the wall, referring to Appendix for correct positioning. Screw in the top wall bolts leaving a small gap between the screw head and the wall. Lower the unit onto the bolts via the key-hole slots in the top of the wall brackets and screw in the bottom wall bolts. Tighten all fixing bolts until the air curtain is safely secured to the wall. Fig T UK (v9) Page 6
7 7. Ceiling Suspension M0 threaded rods (not supplied) are used to suspend the unit from the ceiling. Suspend the unit from the ceiling as follows: Step Screw the threaded rods into all of the holes in the top face of the unit as shown in Fig. OT: Do not screw hanging rods too far in as they could interfere with internal components. Step Fit M0 locking nuts (not provided) to prevent the rod rotating and coming away from the casing. Fig Step Secure each suspension rod to a suitable structure that can support the weight of the unit (see section : Specifications for weights). WARIG: It is the sole responsibility of the installer to ensure that the fixing locations and suspension system used are suitable for the air curtain being installed. 7. LPHW Models For LPHW models ensure that water isolation valves are fitted in the flow and return pipework adjacent to the air curtain and connected correctly as shown in the diagram in Appendix. For the design of the water pipework system and pump, water flow rates and pressure drops for maximum heat output of the air curtain are given in Table below. Table Air Curtain Water Flow Rate (l/min at 8/7 C) Water Pressure Drop (kpa) PHV000W, -row (kw) PHV500W, -row (8kW). 9.5 PHV000W, -row (kw)..7 Air Curtain Water Flow Rate (l/min at 60/0 C) Water Pressure Drop (kpa) PHV000W, -row (kw) PHV500W, -row (8kW) PHV000W, -row (kw) OT: Water Pressure Drop is across the flow and return pipework to the air curtain and includes for the coil fitted inside the unit and the valve fitted in the heating pipework to the unit. Water flow rates and pressure drops at different water temperatures can be calculated using the Thermoscreens coil calculation programme. Visit the Thermoscreens website for details. T UK (v9) Page 7
8 The installer must connect the -port valve in the heating pipework as shown in Figure below: mm pipe mm pipe wire valve to pcb inside air curtain A A/B B mm pipe mm pipe R T U R F L O W Fig 8. ACCSS FOR LCTRICAL COCTIO 8. How to access terminals To gain access to the air curtain for connection and commissioning, remove air inlet grilles and bottom access panel as explained below. First remove the plastic end caps at each end of the unit, if fitted, by pulling off to the side. OT: All air curtain panels are protected in a plastic film. When access panels are removed this film can be removed. 8.. Remove air inlet grilles Using a Pozi o screwdriver, remove each grill with its filter. To remove, insert screwdriver into the elongated hole at the bottom corner of the grille (see Fig 5) and turn the screw one quarter of a turn anticlockwise. Fig Remove bottom access panel Unfasten the securing screw at each end (see, Fig 6) and, if applicable, two screws in the centre (PHV500 and PHV000 units only). To remove, slide the access panel (see, Fig 6) out forwards. Fig 6 T UK (v9) Page 8
9 9. RMOT COTROL ISTALLATIO Mount the copower remote control in a convenient position directly to the wall or onto a switch box. 9. Wall mounting Step Step Step Step Using a screwdriver undo the screw on the top of the remote control case and pull the back case away (see Fig 7). Feed one end of the RJ control cable through the back case, secure it, then screw the back case to the wall using suitable fixings (not supplied). Connect the RJ plug to the RJ socket on the PCB in the remote control. Refit the front case. Fig 7 9. Switch box mounting Step Step Using a screwdriver undo the screw on the top of the remote control case and pull the back case away (see Fig 7). Feed one end of the RJ control cable through the switch box, feed and secure the RJ control cable through the back case and secure back case to switch box using mounting screws (not supplied) (see Fig 8). Step Step Connect the RJ plug to the RJ socket on the PCB in the remote control. Refit the front case. Fig 8 OT: For optional remote control settings see Section RMOT COTROL STTIGS On the back of the PCB inside the copower Remote Control you will find four DIP switches that provide the following optional features, see Table : DIP Feature xplanation Default otes Reset on power-up On restoring power after an electrical interruption all Remote Control settings are retained O Stop fan on cold Fans are switched off when heating level is achieved (AUTO mode only) ever blow cold Air curtain always heats in AUTO mode Room air nables the room air sensor in temperature control the Remote Control OFF OFF OFF WARIG! Fans start on their own after power is restored Will not go to ambient mode Disables all other temperature sensors Table T UK (v9) Page 9
10 . XTRAL COTROLS. Remote switch contacts I0, I Terminals I0 and I on the copower PCB inside the air curtain can be used to provide different control strategies using remote volt-free contacts (see Fig 9). This could be to provide remote On/Off from a timer or BMS Digital/Output contact, to work with a door switch or for simple weather compensation control to disable heating when outdoor air temperatures become warmer. Table describes the different functions: Fig 9 Table Function I0 otes Remote On/Off (IHIBIT) Unit operates normally in MAUAL Mode or AUTO Mode from the Remote Control Unit switches off after 5s, with fan run-on at Medium fan speed if DIP = OFF Use the Remote Control to set up unit and then hide it away if required. * On/Off is then done via I0 using a remote volt-free contact. Function I DIP I0 otes Door Switch Control Summer Winter After 0s the heating is disabled and the fan goes to low speed Unit operates normally in MAUAL Mode or AUTO Mode from the Remote Control COLD DAY Unit operates normally in MAUAL Mode or AUTO Mode from the Remote Control Heating is disabled straight away, Fan speeds operate normally from the Remote Control WARM DAY O OFF Door Open:- ormal Control Door Closed:- Heating Off Low Fan Speed Simple weather compensation control using an outdoor air thermostat with volt free contacts (see Section.) OT: Wire volt-free, remote switch contacts to -way screw terminals I0 and I using -core cable. WARIG: Do not apply any voltage to terminals I0 and I as this will damage the copower PCB inside the air curtain. * OT: The copower Remote Control must stay plugged-in for the air curtain to keep working. An optional plug-in PROM is available from Thermoscreens so the Remote Control can be unplugged and the air curtain stay working. Visit the Thermoscreens website for details. T UK (v9) Page 0
11 . Overheat safety cut-out indication For electric heated air curtains the copower PCB includes a fault indication signal for if the overheat safety cut-out on the electric heater operates. Volt free changeover contacts (6A 50VAC 0VDC) can be wired via the -way screw terminal HALTHY (see Fig 0). Refer to Section 8.: Overheat Safety cut out, for how to reset a overheat safety cut-out situation. Fig 0. Weather compensation control (Summer/Winter) To save heating energy on warmer days a simple weather compensation (Summer/Winter) heat control strategy can be used. Fit an outdoor air thermostat with volt-free contacts (supplied by the installer) to a north facing wall. Use a -core cable to connect the outdoor air thermostat to -way terminal I on the copower PCB (see Fig ) O HALTHY C C ALARM! On the copower PCB, set DIP to OFF as per Table, (see Section.: Remote switch contacts I0, I). Fig Switch Contact Closed = Heating nabled (cold day) Switch Contact Open = Heating Disabled (warm day) Outdoor Air Thermostat WARIG: Do not apply any voltage to terminal I as this will damage the copower PCB. OT: To promote increased energy saving a more advanced weather compensation control strategy is available from Thermoscreens. Using a heating curve, the discharge air temperature of the airstream coming from the air curtain is controlled against the outside air temperature. Visit the Thermoscreens website for details.. MULTIPL AIR CURTAI SYSTMS For master/slave control, plug and connect units together with Thermoscreen RJ extension cables (not supplied) as per Figure below. ach air curtain must have its own electrical supply. maximum 8 units Fig T UK (v9) Page
12 . SYSTM COFIGURATIO. Optional features WARIG: Isolate and disconnect air curtain from the power source before making any changes. DIP switches on the air curtain copower PCB (see Fig ) provide the following optional features, as explained below: Fan heat interlock Disable fan run-on Thermostat master (for master/slave installations) Weather compensation heat control (Summer/Winter) Door switch control Fig Feature DIP setting Default otes Fan heat interlock Allows fan speed to govern heat output on electric heated units. If low or medium fan speed is selected, a lower heat output results. High heat operates only on high fan speed. Disable fan run-on The minute fan run-on after switch off is enabled or disabled on electric heated air curtains. Thermostat master For master/slave installations. Only the air sensor in the thermostat master air curtain is used to measure air temperature. Set DIP to O in the air curtain that will be the master unit. Weather compensation control or Door switch control Simple weather compensation control to save heating energy. or Door switch control. DIP O DIP O DIP O DIP O O Heat output is governed by fan speed. OFF Fan run-on at medium speed enabled. OFF Air curtains in master/slave systems all act independently. OFF I Weather compensation O I Door switch This feature is only used with electric heated air curtains to limit very high air temperatures. Set DIP to OFF if unit is water heated or ambient. Must only be used for water heated or ambient air curtains. ach air curtain must have DIP set to O for no fan run-on. Air sensor thermistors in all slave air curtains will be ignored. Stops some units blowing cold air and others blowing warm air in master/slave systems on larger doorways. See section. Remote Switch Contacts I0 and I for details Weather compensation control is the same as Summer/Winter control OT: rectangle is moveable head of DIP switch. OT: A range of advanced factory fitted and plug-in control options are available from Thermoscreens to enhance the performance of the copower PCB controller inside the air curtain. These include advanced weather compensation control using a heating curve, outlet air temperature control, CObus Modbus BMS control, modulating heater outputs and PROMs for non-standard control strategies. Visit the Thermoscreens website for details. T UK (v9) Page
13 . FA SPD SLCTIO Factory settings for the fan speeds are shown in Table 5 below: (refer also to wiring diagrams in Appendix ) Table 5 Fan Speed Maximum air velocity at outlet grille (m/s) Maximum air curtain mounting height (m) HIGH (black wire).0.0 MDIUM (blue wire) LOW (red wire) Sound Pressure Level of air curtain [db(a) at m] PHV PHV PHV000-6 PHV PHV PHV PHV PHV500-5 PHV Air Volume Flow Rate (m /h) [for & A] Sound pressure levels db(a) at m distance are for a single air curtain mounted at its maximum mounting height, operating in a room with average acoustic characteristics as defined in CIBS Guide B5 (reverberation time 0.7s at khz) and a room size equivalent to 8 air changes per hour (ac/h). Care needs to be taken when selecting air curtains for an installation as noise levels can be several db higher if the mounting height is reduced, if the room is more live (i.e. hard surfaces, no furnishings or absorbent materials), if the room is smaller than 8 ac/h equivalent or a combination of these factors. oise levels will also increase if more than one air curtain is installed at the same doorway (e.g. +db(a) for equal point sources: direct field). 5. RMOT COTROL OPRATIO 5. Remote Control Switch (for Ambient units) On/Off Turns the air curtain fans On or Off., & Fan speed Switch fan speed between Low, Medium and High respectively. T UK (v9) Page
14 5. copower Remote Control (for lectric and Water Heated units) Heating level scale Use the Remote Control to operate the air curtain as follows: On/Off Turns the air curtain On or Off. OT: If an electric heated air curtain is heating when switched off the fan will run-on for approximately minutes to dissipate excess heat. Manual/Automatic Switches between Manual and Automatic modes. The Auto On indicator LD is lit for "Auto Mode" and unlit for "Manual Mode". & Heating level controls Manual mode Select heating level from zero, to half heat, to full heat by stepping up or down with the heating level controls. The heating level scale shows the level selected. Automatic mode Heat output is controlled automatically according to: Inlet air temperature, or Room air temperature This is dependent on the settings made in Section 0: Remote Control Settings (DIP switch ). 5, 6 & 7 Fan speed Switch fan speed between Low, Medium and High respectively. The appropriate LD illuminates. T UK (v9) Page
15 6. COMMISSIOIG TH SYSTM 6. Verify system operation To commission the system, verify the following conditions are met: All fans are working. Fans operate at Low, Medium and High speeds. There is no excessive mechanical noise coming from the fans. When heating is selected, the air stream from the discharge grille warms up across the whole length of the air curtain. When set to manual with fans set to high speed, heating increases as higher heat is selected. Warm air reaches across the doorway with door open or closed. copower Remote Control operates correctly in both manual and auto modes. 6. Instruct customer and hand over Before leaving site, hand over the installation to the customer/end user or their representative. xplain that any person operating the air curtain must be given supervision and instruction by the person responsible for their safety, concerning the safe use of the unit and to understand any hazards involved. Children and those with reduced physical, sensory or mental capabilities should not operate the air curtain. Recommend that the doorway should be closed whenever possible but that during times of high pedestrian use it will become an open doorway. The air curtain then serves an essential purpose by saving energy and providing comfort to occupants. xplain that the inlet grilles and air filters (if fitted) must be cleaned regularly and the unit serviced at schedule intervals see section 9: Service & Maintenance. OT: Leave these instructions with the customer/end user or their representative!! 7. SIG OFF Complete the following once commissioning is completed: Installer signature Installer name Installer company Date Customer signature Customer name Customer company Date T UK (v9) Page 5
16 8. FAULT CODITIOS 8. Overheat Safety cut-out An overheat fault in electric heated units may cause the overheat safety cut-out(s) to operate. This is indicated by flashing LDs on the Remote Control and a red status LD on the copower PCB inside the air curtain. Before resetting ensure there is adequate air flow from the air curtain and the unit has been commissioned as per section 6. To reset a overheat safety cut-out: Step Step Step Step Switch off the electrical supply to the air curtain. Allow time for the air curtain to cool down, typically 0 minutes. Switch on the electrical supply to the air curtain. Press the Auto button on the copower remote control times. Air curtain heaters will then operate and after 0 seconds the LDs on the remote control will stop flashing and the status LD on the copower PCB in the air curtain will flash green. 8. Fuses In the event of an electrical fault internal electrical fuses may operate. There are two internal fuses located on the copower PCB inside the air curtain: Fuse 6.A(T) supplies the fan motors within the air curtain Fuse 00mA(F) controls the circuitry of the copower PCB 8. copower PCB status indication There is a status LD on the copower PCB inside the air curtain (See LD shown on Wiring Diagrams in the Appendix). This indicates the status of the copower Control system as follows:. LD flashing green operation normal. LD flashing red low supply voltage, remote control not plugged in or RJ cable fault. LD permanently red overheat safety cut-out(s) open circuit from an overheat situation (see Section 8: Fault Conditions for how to reset) T UK (v9) Page 6
17 9. SRVIC & MAITAC WARIG: Failure to adequately maintain the unit and provide a suitable cleaning schedule will result in a loss of performance and reduced life expectancy of the air-curtain and possible overheating and fire risk with electric heated units. 9. very week OT: Weekly maintenance can be carried out by the Cleaner or Janitor from floor level. Turn off the air curtain to prevent entry of dust then clean the face of the air inlet grilles and air filters inside the grilles using a vacuum cleaner with an extension tube and brush. 9. very months WARIG: Before servicing, isolate and disconnect the air curtain from the electrical power. WARIG: The following servicing and maintenance must be carried out by a competent electrician or a Thermoscreens appointed technician. Clean and inspect the inside of the air curtain as follows: Step Step Step Remove plastic end caps at each end of the unit by pulling off to the side. Use a Pozi o. screwdriver to remove air inlet grilles by releasing the fasteners at the bottom corners of each air inlet grille. See Fig 5, Section 8... Clean and remove any build-up of dust and dirt within the air-curtain (inlet/outlet grilles, electric heaters, fan impellers, housings and motors) using a vacuum cleaner and soft brush. OT: Build-up of dirt on fan impellers can cause vibration, noise and excessive wear on the motor bearings. Step Check within the unit to ensure all electrical connections and crimped terminals are tight and that all cables are in good condition. Refit air inlet grilles after servicing. Reconnect electrical supply and test to ensure correct operation (see Section 6: Commissioning). T UK (v9) Page 7
18 0. WARRATY All units are covered by a two year warranty. Failure to adequately maintain the unit may void the warranty. If any problems are encountered, please contact your installer/supplier. Failing this please contact the Thermoscreens warranty department. Care has been taken in compiling these instructions to ensure they are correct. Thermoscreens Ltd. disclaims all liability for damage resulting from any inaccuracies and/or deficiencies in this documentation. Thermoscreens Ltd. retain the right to change the specifications stated in these instructions. Thermoscreens Ltd mail: sales@thermoscreens.com St. Mary s Road uneaton Tel: + (0) Warwickshire ngland Fax: + (0) CV 5AU T UK (v9) Page 8
19 G F F 00 (min.) AIR I 5 AIR OUT 77 ntry point for electrical supply and controls mm Remote control connection interface A B D C C PHV000 PHV500 PHV A 97 Rp¾ in. BSP LPHW connections Inserts for M0 drop rods, use for m units use 6 for.5m/m units G B C D F G 8 H 8 H APPDIX Dimensions of PHV Surface Mounted Air Curtain D 68 6 T UK (v9) Page 9
20 kw (x) Second Stage Heating (top elements) TRMIAL BLOCK 00V / ph / 50Hz Grey L L L L L L 85 C Auto Thermal Trip Healthy Alarm Summer/Winter or Door Contact To Slave Air Curtain F = F00mA F = T6.A J C C O F F J LD I I0 R0-0V J5 Master/Slave Cable J6 Th J9 O RMOT COTROL Grey J0 PROM kw (x) L J J rectangle is moveable head of DIP switch J L 6 High speed Med speed Low speed 0V 5 First Stage Heating (bottom elements) L High speed Med speed Low speed 0V Fan Fan J6 0 J7 CO-Power CVR008-9 Capacitor: 7.5µF Fan Motor (COMMO) (High) (Low) ~ Yellow 0 APPDIX A WIRIG DIAGRAM PHV000 T UK (v9) Page 0
21 kw (x) Second Stage Heating (top elements) Grey TRMIAL BLOCK L L L 00V / ph / 50Hz L L L 85 C Auto Thermal Trip Healthy Alarm Summer/Winter or Door Contact A O 5 To Slave Air Curtain F = F00mA F = T6.A J C C O F F J5 COTACTOR 0V AC Coil J LD I I0 R 0-0V Master/Slave Cable J6 A O 6 Th J9 O RMOT COTROL J0 PROM L J J rectangle is moveable head of DIP switch J L 6 High speed Med speed Low speed 0V kw (x) 5 Grey L High speed Med speed Low speed 0V Fan Fan J6 0 J7 CO-Power CVR008-9 First Stage Heating (bottom elements) Fan Motor (COMMO) (High) (low) ~ Yellow Capacitor: 7.5µF 0 APPDIX B WIRIG DIAGRAM PHV500 T UK (v9) Page
22 Grey A O 5 COTACTOR 0V AC Coil A O 6 kw (x) kw (x) Second Stage Heating (top elements) TRMIAL BLOCK TRMIAL BLOCK 00V / ph / 50Hz L L L L L L L L L Grey 85 C Auto Thermal Trip (x) Healthy Alarm Summer/Winter or Door Contact A O 5 To Slave Air Curtain F = F00mA F = T6.A J C C O F F J5 COTACTOR 0V AC Coil J LD I I0 R0-0V Master/Slave Cable J6 A O 6 Th J9 O RMOT COTROL J0 PROM L J J rectangle is moveable head of DIP switch J L High speed Med speed Low speed 0V 5 kw (x) kw (x) 6 7 L High speed Med speed Low speed 0V Fan Fan 8 9 J6 0 J7 CO-Power CVR008-9 Fan Motor (COMMO) (High) (Low) ~ Yellow Capacitor: 7.5µF 0 Fan Motor ~ (COMMO) (High) (Low) Yellow First Stage Heating (bottom elements) Capacitor: 7.5µF 0 APPDIX C WIRIG DIAGRAM PHV000 T UK (v9) Page
23 TRMIAL BLOCK 0V / ph / 50Hz L L PORT VALV Summer/Winter or Door Contact To Slave Air Curtain J F = F00mA F = T6.A J C C O F F LD I I0 R 0-0V J5 Master/Slave Cable Grey Orange Green/Yellow J6 Th J9 O RMOT COTROL J0 PROM L J J rectangle is moveable head of DIP switch J 5 L 6 High speed Med speed Low speed 0V 7 8 L High speed Med speed Low speed 0V Fan Fan 9 J6 0 J7 CO-Power CVR008-9 Fan Motor Capacitor: 7.5µF ~ (COMMO) (High) (Low) Yellow 0 Fan Motor (m only) Capacitor: 7.5µF ~ (COMMO) (High) (Low) Yellow 0 APPDIX D WIRIG DIAGRAM PHV000W, PHV500W and PHV000W T UK (v9) Page
24 Low speed Medium speed High speed 0V / ph / 50Hz L TRMIAL BLOCK L F (5A) 0 Fan Motor (COMMO) (High) (Low) Yellow ~ Capacitor: 7.5µF Fan Speed On/Off Remote Control Switch Fan Motor (m only) 0 (COMMO) (High) (Low) Yellow ~ Capacitor: 7.5µF 0 I APPDIX WIRIG DIAGRAM PHV000A, PHV500A and PHV000A T UK (v9) Page
25 . DCLARATIO OF COFORMITY Thermoscreens Ltd. St. Mary s Road uneaton Warwickshire CV 5AU United Kingdom Telephone: + (0) C DCLARATIO OF COFORMITY as defined by the C Council Directive on Machinery 006//C, the Low Voltage Directive 006/95/C, lectromagnetic Compatibility Directive 00/08/C, the nergy related Products Directive 009/5/C Herewith we declare that the air movement equipment designated below, on the basis of its design and construction in the form brought onto the market by us in accordance with the relevant safety, health and performance requirements of the Machinery. If alterations are made to the machinery without prior consultations with us, this declaration becomes invalid. Designation of quipment: Series Type: Relevant C Council Directives: AIR CURTAIS PHV000A; PHV000; PHV000W; PHV500A; PHV500; PHV500W; PHV000A; PHV000; PHV000W (in Casing Styles: Surface Mount and Recessed) the Machinery Directive (006//C) the Low Voltage Directive (006/95/C) the lectromagnetic Compatibility Directive (00/08/C) the nergy related Products Directive (009/5/C) Applied Harmonised Machinery - ISO -:007, 9:99, :000 Standards: LVD :0, :009+A:0 MC :007, :007+A:0, :006+A:009, :008 rp - Commission Regulation (U) o.7/0, ISO 580:007, ISO 759:00 Basis of Self Attestation: Quality Assurance to BS ISO 900: 008 B.S.I. Registered Firm Certificate umber FM 85 SGS Test Report LS5009//R/DC/; SGS Test Report MC5009/ C Marking Association Test Report 6799 and 6800 Responsible Person: Mr. P.Casey, Operations Director, Thermoscreens Ltd. Date: 0 March 0 Signed: T UK (v9) Page 5
AIR CURTAIN T SURFACE MOUNTED RANGE
AIR CURTAIN T SURFACE MOUNTED RANGE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS English T990009-- UK (v9) Page CONTENTS Page CONTENTS... ELECTRICAL SAFETY... SPECIFICATIONS.... INTRODUCTION...
More informationAIR CURTAIN COMPACT 2 SURFACE MOUNTED RANGE
AIR CURTAI COMPACT SURFACE MOUTED RAGE ISTALLATIO, OPERATIO AD MAITEACE ISTRUCTIOS English T9900-- UK Page ` COTETS Page COTETS... ELECTRICAL SAFETY... SPECIFICATIOS.... ITRODUCTIO.... DELIVERY COTETS...
More informationAIR CURTAIN HX RECESSED RANGE
AIR CURTAI HX RECESSED RAGE ISTALLATIO, OPERATIO AD MAITEACE ISTRUCTIOS English T990098-- UK (v9) Page COTETS COTETS... ELECTRICAL SAFETY... SPECIFICATIOS.... ITRODUCTIO.... DELIVERY COTETS... 6. TOOLS
More informationAIR CURTAIN HX RECESSED RANGE
AIR CURTAIN HX RECESSED RANGE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS English 990098-- Page CONTENTS CONTENTS... ELECTRICAL SAFETY... SPECIFICATIONS.... INTRODUCTION... 5. DELIVERY CONTENTS...
More informationPHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens Ltd St. Mary s Road Nuneaton Warwickshire
More informationT-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens Ltd St. Mary s Road Nuneaton Warwickshire
More informationINCORPORATION & INSTALLATION INSTRUCTIONS. For incorporating a heat pump control system by others
HX2 DX HEAT PUMP AIR CURTAINS NO CONTROLS INCORPORATION & INSTALLATION INSTRUCTIONS For incorporating a heat pump control system by others PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INCORPORATING
More informationHP RECESSED HEAT PUMP RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. For use with Mr Slim Outdoor Units
ErP compliant HP RECESSED HEAT PUMP RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS For use with Mr Slim Outdoor Units PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION
More informationVRF HP HEAT PUMP RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. For use with City Multi (VRF) systems
VRF HP HEAT PUMP RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS For use with City Multi (VRF) systems PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens
More informationPHV2000NT CHILLED WATER HEAT PUMP, SENSIBLE/DRY COOLING UNIT INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
PHV2000NT CHILLED WATER HEAT PUMP, SENSIBLE/DRY COOLING UNIT INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS For use with PUHZ-HW140VHA2 or YHA2 Outdoor Units PLEASE READ THESE INSTRUCTIONS CAREFULLY
More informationInstruction Manual WARNINGS
Instruction Manual LARGE COMMERCIAL RECESSED AIR CURTAIN HSACR9000, 12000 & 18000 ELECTRICALLY HEATED RECESSED AIR CURTAINS WITH ENERGY SAVING CONTROLS INSTALLATION AND OPERATING MANUAL INDEX Section General
More informationRecessed. Air Curtain. Fig 1. Recessed air curtain
the future of space conditioning recessed www.frenger.co.uk an FTF Group Company Recessed Introduction These recessed s create an air barrier, which helps to prevent cold draughts thus creating a comfortable
More informationThe CAB & DAB Air Curtains
The CAB & DAB Air Curtains Frequently Asked Questions General Positioning Page 2 Electrical & Connection Page 4 Electric Heated Page 5 Electronic door triggered shutdown feature (Electric) Page 5 Electronic
More informationSURFACE WARM CEILING HEATERS
SURFACE WARM CEILING HEATERS CATALOGUE NUMBERS HE7237, HE7247, HE7267, HE7237RF, HE7247RF, HE7267RF INSTALLATION AND OPERATING MANUAL INDEX Section General information ------------------------------------------------------------1
More informationRECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL
HSPBRF HSTIRF HSVTRF RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL INDEX Section General information -----------------------------------------------------------
More informationOriginal instructions AR
Original instructions SE... 8 GB... 22 NO... 27 FR... DE... 6 ES... 4 NL... 46 IT... 5 RU... 56 Dimensions and connections AR20/AR25 M8 002/52 940/450 494 449 92 20 98 042/552 42 20 AR20/25A/E 40 275 DN5
More informationImperial Electric Fires
Imperial Electric Fires GB IE MODELS: Flamescape II Curvascape II manual & remote. Installation and User Instructions PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE REFERENCE This electric
More informationCASSETTE UNIT. Comfort Circle
CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool
More informationINFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS
INSTRUCTIONS FOR: INFRARED IP55 HEATER MODEL:- QZWP45N Thank you for purchasing a Consort Claudgen product. Manufactured to a high standard this product will, if used according to these instructions and
More informationFHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P
FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure
More informationInstallation Instructions & Operating Manual IMPORTANT
Installation Instructions & Operating Manual IMPORTANT These instructions should be read carefully and retained for future reference TABLE OF CONTENTS SECTION 1: WARNINGS & ELECTRIC SPECIFICATIONS 1.1
More informationSurface Warm Ceiling Heaters
CONSORT Wireless controller CRX2 SLPB SLTI SLVT SLVTB Surface Warm Ceiling Heaters Catalogue Numbers HE7237SL, HE7247SL, HE7267SL, HE7237RX, HE7247RX, HE7267RX Installation and Operating Manual INDEX Section
More informationTECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:
TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA
More informationMRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.
MRXBOX95-WA Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The ow Voltage Directive 2006/95/EC 1.0 Introduction Figure 2. Fixing
More informationECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance
TOP ECOSMART TWINFANS (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use Installation and Maintenance The EMC Directive 2014/30/EU The Low Voltage directive 2014/35/EU INDOOR USE ONLY Introduction
More informationNatural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised
Natural Ventilation e-stack A-Series Ventilation System for Buildings with Atria Installation and Maintenance The EMC Directive 004/108/EC The Low Voltage directive 006/95/EC Important Notes to Designers
More informationManual Comfort Air Curtain
Manual Comfort Air Curtain Model DF Version 2.0 Original Manual English a COMFORT AIR CURTAIN... Contents 1 Introduction 3 1.1 About this manual 3 1.2 How to read this manual 3 1.3 About the unit 4 1.4
More informationRecessed Warm Ceiling Heaters
CONSORT Wireless controller CRX2 SLPB SLTI SLVT SLVTB Recessed Warm Ceiling Heaters Catalogue Numbers HE7230SL, HE7245SL, HE7260SL, HE7230RX, HE7245RX, HE7260RX Installation and Operating Manual INDEX
More informationUser Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276
200662_2 Page 1 User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276 These instructions should be read carefully and retained for future reference. Important Notes These
More informationUnvented Electric Water Heater 10/15 litre Undersink
Unvented Electric Water Heater 10/15 litre Undersink Fitting Instructions and User Guide 1 CONTENTS SECTION PAGE 1.0 INTRODUCTION 2 2.0 TECHNICAL SPECIFICATION 3 3.0 INSTALLATION 4 4.0 COMMISSIONING 9
More informationMRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance
MRXBOX95B-LOFT Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage directive 2006/95/EC 1.0 Introduction
More informationInstallation, operation and Maintenance Manual
Installation, operation and Maintenance Manual Unit: TRW & TRE 1 Pre installation 1.1 Delivery check 1.2 Handling 1.3 Storage 2 Installation 2.1 General 2.2 Hanging the unit 2.3 Pipe connections 2.4 Electrical
More information3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS
3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: 32305600 OPERATION & MAINTENANCE INSTRUCTIONS 0304 Parts List Item Part No Description Qty 1 FT900001 Top Cover 1 2 FT900002 Filter
More informationColorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)
Colorado SCR Electric Towel Radiator Operating and Installation Instructions (Read these instructions carefully and retain for future reference) Models SCR 300 300W SCR 450 450W SCR 750 750W NOTE A qualified
More informationCFS30, CFS60, CFS90 & CFS120 Standard Wall Mounted Fan Heater
,, & Standard Wall Mounted Fan Heater 08/19437/1 (UK) Issue 1 he product complies with the uropean Safety Standards 60335-2-30 and the uropean Standard lectromagnetic Compatibility (MC) 55014, 60555-2
More informationInstallation, operating and servicing instructions
English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes
More informationIMPORTANT INSTRUCTIONS READ & SAVE
7,500W/240V WALL / CEILING MOUNTED GARAGE HEATER OWNER S MANUAL Model: DR-975 7500W 240V 60Hz IMPORTANT INSTRUCTIONS READ & SAVE 1 TABLE OF CONTENTS Important Instructions. 3 Installation Instructions...
More informationInstallation & User Instructions: Model: Arizona/Broadway/Corsano/Compton/Compton1000/Corbiere/Empire /Newark/Newark1000/Qube/Tribeca
Installation & User Instructions: Model: Arizona/Broadway/Corsano/Compton/Compton1000/Corbiere/Empire /Newark/Newark1000/Qube/Tribeca Once installed, the installer should take the appropriate steps To
More informationPLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS
eturboprop High Pressure Axial Fans Installation and Wiring Instructions Stock Ref. 45012 50012 56012 63012 45032 50032 56032 63032 PLAS RAD ISTRUCTIOS I COJUCTIO WITH TH ILLUSTRATIOS. PLAS SAV THS ISTRUCTIOS
More informationIMPORTANT INSTRUCTIONS READ & SAVE
5,000W/240V WALL / CEILING MOUNTED GARAGE HEATER WITH ELECTRONIC CONTROLLER AND REMOTE OWNER S MANUAL IMPORTANT INSTRUCTIONS READ & SAVE Model: PH-950NR PET OWNERS WARNING: The health of some small pets
More informationLC3000 Level Controller Installation and Maintenance Instructions
4025550/12 IM-P402-36 AB Issue 12 LC3000 Level Controller Installation and Maintenance Instructions 1. General safety information LC3000 NORM ALARM TEST 2. General product information 3. Installation 4.
More informationInstallation and Maintenance. Opus OK / Genie NKF1 Kitchen Extract Unit. Contents IMPORTANT WARNING IMPORTANT! Introduction WARNING!
Installation and Maintenance Opus OK / Genie KF Kitchen Extract Unit uaire imited Western Industrial Estate Caerphilly, Mid Glamorgan CF8 XH Telephone: 09 088 59 Facsimile: 09 088 70 Email: info@nuaire.co.uk
More informationCENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL
CENTRIFUGAL FAN IN SCROLL CASING Helix S-Vent EN OPERATION MANUAL Helix / S-Vent www.blaubergventilatoren.de CONTENTS CONTENTS 3 Introduction 3 Use 3 Delivery set 4 Technical data 10 Safety requirements
More informationINDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use
TOP INDOOR USE ONLY Introduction Units are rectangular in section and have circular/rectangular rigid spigots at each end. Four matching mounting feet are supplied with the unit. Full size access panels
More informationCommercial Fan Heater
Commercial Fan Heater Installation and Operating Manual Catalogue Numbers: CH06CSiRX, CH06CPiRX, CH09iRX, CH12iRX, CH15iRX. INDEX Section General Information -----------------------------------------------------------
More informationHand Dryer Installation & User Manual
Hand Dryer Installation & User Manual Please read instructions in conjunction with the illustrations Please save these instructions. Safety & Guidance notes Important:- Read all these instructions before
More informationXB-EFA-8L-BK & XB-EFA-8R-BK
Supply & Extract Ventilation Unit with Heat Recovery The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU The information contained in this document provides details of installation, operation
More informationIMPORTANT INSTRUCTIONS READ & SAVE
7,500W/240V WALL / CEILING MOUNTED GARAGE HEATER OWNER S MANUAL Model: DR-975 7500W 240V 60Hz IMPORTANT INSTRUCTIONS READ & SAVE 1 TABLE OF CONTENTS Important Instructions. 3-4 Installation Instructions...
More informationOriginal instructions. Panther 6-15 kw
Original instructions 6-15 kw SE... 8 GB... 10 NL... 12 IT... 14 ES... 16 FI... 18 DE... 20 FR... 22 NO... 24 RU... 26 PL... 28 6/15 Fig 1. Bracket 100 ø7 520 90 ø6,5 ø14 450 510 Fig 2. Ceiling Wall 30
More informationMEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.
MEV-DC Continuous Mechanical Extract Ventilation s Installation and Maintenance The EMC Directive 2014/30/EU The ow Voltage directive 2014/35/EU 1.0 Introduction uaire's MEV-DC units are designed to provide
More informationisense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans
isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATI The installation
More informationIMPORTANT INSTRUCTIONS READ & SAVE
5000W Ceiling/Wall Mounted Garage Heater OWNER S MANUAL Model: PH-950N IMPORTANT INSTRUCTIONS READ & SAVE PET OWNERS WARNING: The health of some small pets including birds are extremely sensitive to the
More informationSMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL
Instruction Manual. SMARTELEC 2 SmartElec ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL 0 F1 INDEX Section General information ------------------------------------------------------------ 1 Dimensions
More informationWELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH
Zephyr 16 DC FAN WELCOME Thank you and congratulation for choosing an EcoAir DC Fan to help you improve the air quality within your home. Inside you will find many helpful tips on how to use and maintain
More informationModel 1174 Electric Heater User instructions for LED effect 2kw Inset Heater
200688_6 Page 1 Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater These instructions should be read carefully and retained for future reference Important Notes This heater must
More informationAC25. Art.nr:
GB Installation and maintenance instruction for air curtains IMPORTANT: Read these instructions before the product is installed and used. Save the instructions for future use...2 Art.nr: 172785-01 Assembly
More informationGeneral Care and Safety Guide
General Care and Safety Guide Thank you for choosing a Goldair product. This Goldair unit has been designed and manufactured to high standards of engineering and with proper use and care, as described
More informationMEV Ecosmart. Installation and Maintenance. Continuous Mechanical Extract Ventilation Units. 1.0 Introduction
MEV Ecosmart Continuous Mechanical Extract Ventilation Units Installation and Maintenance ICUDIG MEV-SVS 1.0 Introduction uaire's MEV Ecosmart units are designed to provide continuous mechanical extract
More informationSOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59
SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery
More informationFLCH4R Garage and Utility Electric Heater
FLCH4R Garage and Utility Electric Heater Installation, Operation & Maintenance Instructions Model No. Volts Amps Watts BTU/HR Phase High Low High Low High Low Min Fuse Size* FLCH4R 208 17.3 8.66 3600
More informationInstallation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3
Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3 Once installed, the installer should take the appropriate steps To ensure that the user understands how
More informationSanitary Water Tank INSTALLATION & SVC MANUAL
http://biz.lgservice.com Sanitary Water Tank INSTALLATION & SVC MANUAL MODEL : PHS Series CAUTION Before Servicing the unit, read the safety precautions in this manual. Only for authorized service personnel.
More informationEH kW Panel Heater
EH1390 1.5kW Panel Heater Adjustable thermostat 24 hour timer Wall mounting or free-standing Silent operation Stylish, slim design Safety overload cut-out 2 year guarantee Page 1 IMPORTANT Installer and
More informationFAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans
FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATION
More informationAP-EH500-L/RQA9837. Installation Guide
AP-EH500-L/RQA9837 Duct Mounted Burst Fire Heater The EMC Directive 2004/108/EC The Low Voltage directive 2006/95/EC 1.0 Duct Mounted Burst Fire Heater This Burst Fire Heater should only be used as a supplementary
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL. Air curtain SMART
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Air curtain SMART Read instructions carefully before attempting installation. Deliver this manual to end user. SECURITY ADVISE SYMBOLS Attention, Danger,
More informationHIT Centrifugal In-Line Fan
HIT Centrifugal In-Line Fan 1. WARNING This fan is fitted with a non self-resetting thermal cut-out which switches the fan off in the event of a fault condition. To reset, turn the power off for one minute,
More informationINSTALLATION & USER INSTRUCTIONS
INSTALLATION & USER INSTRUCTIONS BLENHEIM LED ELECTRIC FIRE BLENHEIM LED INSET ELECTRIC FIRE All instructions must be handed to the user for safekeeping. Revision D - 04/4 I N S TA L L AT I O N & U S E
More informationUNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.
UNDERCOUNTER SERVICE MANUAL Ecoboiler UC4L 2.4kW 1000740 Ecoboiler UC10L 2.8kW 1000741 Ecoboiler UC10L 5.6kW 1000742 Ecosmart UC4L 2.4kW 1000750 Ecosmart UC10L 2.8kW 1000751 Ecosmart UC10L 5.6kW 1000752
More informationImperial Electric Fires
Imperial Electric Fires GB IE MODELS: Flamescape III & Curvascape III manual / remote Installation and User Instructions PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE REFERENCE This electric
More informationWORLDWIDE DISTRIBUTORS
WORLDWIDE DISTRIBUTORS Australia Austria Bahrain Belgium Brazil Bulgaria Canada Chile Cyprus Denmark Estonia Finland France Germany Hungary Iceland Italy Kazakhstan Kuwait Latvia Lithuania Malta Oman Poland
More informationSTREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30
STREAMLINE OVERSINK Fitting Instructions and User Guide 1 36005997_iss_05.indd 1 15/09/2015 08:46:30 CONTENTS SECTION PAGE 1.0 INTRODUCTION 3 2.0 TECHNICAL SPECIFICATIONS 4 3.0 INSTALLATION 6 4.0 COMMISSIONING
More informationElectronic Dual Cylinder Thermostat Installation Instructions
ESCTDEB Electronic Dual Cylinder Thermostat Installation Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect
More informationECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.
ECONOPLATE H1-heat only HEAT INTERFACE UNIT Installation, Commissioning and Servicing Instructions for vented systems. Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,
More informationINLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL
INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL CONTENT 3 Introduction 3 General 3 Safety rules 3 Storage and transportation rules 3 Manufacturer s warranty 4 Fan design 4 Delivery set 5 Technical data
More informationMRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.
MRXBOX95-LH1/LH2 Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction Unit must
More informationWARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.
VBT3ASV USER GUIDE SAFETY INFORMATION About this user guide Read this user guide completely before using the machine. Keep this user guide for reference. If you pass your machine on to third parties, it
More informationEVG Extractors. Manual for Installation, Use and Maintenance
EVG Extractors Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W :
More informationTHE QUALITY BRAND IN FANS
THE QUALITY BRAND IN FANS CAUTION! DO NOT THROW AWAY THIS BOOK! READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION AND FAN OPERATION. Minor design changes or otherwise may result in slight variations
More informationnergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or
Domestic AC Fans 230V Installation and Operating Guide 230V AC Base Models: ico15 72683501 ico15c 72591501 ico30 72591601 ico60 72591701 ico Domestic Fan 230V Installation, Maintenance and Use ico Domestic
More informationHS&S Alert No: 103 Date: 9 March 2017
HS&S Alert No: 103 Date: 9 March 2017 RECENT CABIN FIRES WALL MOUNTED DOWN FLOW HEATER UNITS This is an update to Alert No 83, following a further cabin fire involving a wall mounted downflow heater unit.
More informationOWNERS INSTRUCTION MANUAL
OWNERS INSTRUCTION MANUAL 132CM/52 Classic INSTALLATION OPERATION MAINTENANCE CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN SUITABLE
More informationMODELS HSCFH60WX, HSCFH90WX, HSCFH120WX
Commercial Inst allation Fan Heater and Operating Manual MODELS HSCFH60WX, HSCFH90WX, HSCFH120WX INDEX Section General Information ----------------------------------------------------------- 1 Installation
More informationSHORT WAVE INFRARED PANEL DRYER
INSTRUCTIONS FOR: SHORT WAVE INFRARED PANEL DRYER MODEL: IR3000 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
More informationSENSA MRE DDM MR
96239831 SENSA MRE DDM MR Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring and fixing 3 4 Programming 6 5 Wiring diagrams 8 6 Detection pattern diagrams
More informationInstallation, Operating and Servicing Instructions
Installation, Operating and Servicing Instructions Wall Mounted Water Boiler WMB3F/B,WMB3F/W Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number: Dealer:
More informationINSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS
INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS WM-FM-50-BG SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly, a fire or explosion may
More informationINSTALLATION & USER INSTRUCTIONS
INSTALLATION & USER INSTRUCTIONS LED ELECTRIC FIRE Focal Point Fires plc. Christchurch, Dorset BH23 2BT Tel: 01202 499330 Fax: 01202 499326 www.focalpointfires.co.uk e : sales@focalpointfires.co.uk MODELS
More informationInstallation and Maintenance
1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The
More informationInstructions for the fan motor control system with integrated wiring terminals SILVER C
Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.
More informationInstallation Instructions & Operating Manual. Heat Exchanger PLEASE READ CAREFULLY BEFORE INSTALLING. Incorrect Installation Will Affect Your Warranty
Heat Exchanger Installation Instructions & Operating Manual PLEASE READ CAREFULLY BEFORE INSTALLING Incorrect Installation Will Affect Your Warranty Do Not Discard, Keep For Future Reference ELECRO HEAT
More informationModel: AC-108. Instruction Manual
Model: AC-108 Instruction Manual Attention: This appliance is not intended for use by persons (including Children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge
More informationSERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )
SERVICE MANUAL Ecoboiler Model range: T20 (1000662) T30 (1000663) Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ireland Tel: (01) 295 2674 Ireland
More informationQUALITY SPACE HEATERS
QUALITY SPACE HEATERS Installation & Control Guide for Panel Convector Heaters With Electronic Controls Models PLE050/SS PLE075/SS PLE100/SS PLE125/SS PLE150/SS PLE200/SS Please note: SS suffix added to
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Air Curtains MAX Please, read these instructions carefully before attempting installation SECURITY ADVISE SYMBOLS Attention, Danger, Safety Advice! Danger
More informationUSER S MANUAL. VKP Series INLINE FAN
USER S MANUAL Series INLINE FAN 2 CONTENTS Safety requirements 3 Introduction 5 Use 5 Delivery set 5 Designation key 5 Technical data 5 Design and operating logic 8 Mounting and set-up 8 Connection to
More informationWAILEA OWNER S MANUAL
WAILEA OWNER S MANUAL The blades in each pack are matched for equal weight to assure smooth fan operation. If more than one fan is being installed, be careful not to mix blades from different cartons.
More informationWhole Room Dryer WRD, WRD/110
Whole Room Dryer WRD, WRD/110 User Instructions Whole Room Dryers CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-8117-0000 Iss.1 12/06 Fig 1 Fig 2 Fig 3 Fig 4 CONTENTS Page 1 Product information...................4
More informationECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance
EST-X Figure 1. EST-X unit. Removable top panel D Control module located internally External Commissioning box Table 1. EST-X Dimensions (mm) Weight Code A B C D dia. (kg) EST1-X 705 505 355 125 22 EST2-X
More informationInstallation & Operating Instructions. Models: York Midi & Serrano Electric Stoves
Installation & Operating Instructions Models: York Midi & Serrano Electric Stoves PLEASE NOTE THAT THIS APPLIANCE USES A MOTOR TO OPERATE THE FLAME EFFECT AND THAT IT MAY BE POSSIBLE TO HEAR IT WHERE THE
More information