THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD

Size: px
Start display at page:

Download "THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD"

Transcription

1 The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC6000 controller. When installed with an optional 00% free cooling economizer, the unit will supply full-rated airflow in free cooling mode with the ability to exhaust unconditioned indoor air without the need for additional relief openings in the structure. tandard Features All Models THE MULTI-TEC WALL-MOUNT AIR CONDITIONER 0 EER (50 HZ) WITH LOGIC BOARD Models W24AAP to W72ABP Right ide Control Panel Models W24LAP to W72LBP Left ide Control Panel 22,400 Btuh (6.56 KW) 64,700 Btuh (8.96 KW) MULTI-TEC WALL-MOUNT Features All Models PLC Logic Board: Unit control panels are equipped with PLC Logic Boards that allow multiple unit operation with a single controller. Unit connection to the LC controller is accomplished via 2 wire with drain (ground). Dirty Filter witch: Field adjustable with alarm signal. Advanced Unit Diagnostics: When connected to the TEC-EYE diagnostic tool, the unit PLC logic board is able to display stored alarms and easy-to-read diagnostic information. The TEC-EYE also displays unit model and serial number. Remote Monitoring: Bard-Link web interface with use of LC Controller. Free Cooling Unit: Full flow free cooling unit economizer with positive shutoff sealing as optional equipment. Proper operation is verified through alarm notifications. NOTE: All of the above Features are unique to the MULTI-TEC. For Export Only Copper Tube / Aluminum Fin s: Grooved copper tubing and enhanced aluminum fins provide maximum heat transfer and high energy efficiency. Optional phenolic-coated coils are also available. Twin Blowers: Move air quietly with standard dual blower configuration on slide tracks for service. R-40A Refrigerant: Designed with R-40A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 200 EPA requirements. Galvanized 20 Gauge Zinc Coated teel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 000 hours of salt spray tests per ATM B7-03. Condenser section and entire cabinet coatings are also available. Foil Faced Insulation: tandard on all units. A/C Unit Controls: All unit controls rated at -40C/-40F. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Liquid Line Filter Drier: tandard on all units. Protects system against moisture. Compressor Control Module: tandard on all units. Built-in offdelay timer adjustable from seconds to 5 minutes. 2-minute on-delay if power interrupt. 20-second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. Electrical Components: Are easily accessible for routine inspection and maintenance through side service panel opening. Features a lockable, hinged access cover to the circuit breaker. 24V Transformer: 00VA with circuit breaker Electric Heat trips: Features an automatic limit and thermal cut-off safety control. Heater packages are factory installed. One-Inch, MERV 2 Air Filters: Are standard equipment. All models include tight-sealing U-channel filter bracket to minimize air bypass around the filter. Condenser Fan and Motor hroud Assembly: lides out for easy access. Built-In Circuit Breakers: HACR-type circuit breakers are standard for AC power supply. lope Top: tandard feature for water run-off. Top Rain Flashing: tandard feature on all models. High & Low Pressure witches are Auto-Reset: tandard on all units. Built-in lockout circuit resets from the Bard-Link Controller. Provides commercial quality protection to the compressor. Low Ambient Control: Fan cycling LAC standard on all models. crew-on fitting design for ease of service. Evaporator Freeze Protection: tandard on all units. Phase Rotation Monitor (3-Phase Units Only): Protects against reverse rotation if AC power supply is not properly connected. MULTI-TEC WALL-MOUNT Unit LC6000 Controller Certified to ANI/ARI tandard for PVU (ingle Package Vertical Units). Complies with efficiency requirements of AHRAE/IENA Intertek ETL Listed to tandard for afety Heating and Cooling Equipment ANI/UL 995/CA 22.2 No , Fourth Edition. Commercial Product - Not intended for Residential application. Bard is an IO 900:2008 Certified Manufacturer Page of 4

2 Capacity and Efficiency Ratings MODEL W24AAP W24LAP WAAP WLAP W36AAP W36LAP W42AAP W42LAP Capacity is certified in accordance with ANI/ARI tandard EER = Energy Efficiency Ratio and is certified in accordance with ANI/ARI tandard All ratings based on fresh air intake being 00% closed (no outside air introduction). W48AAP W48LAP W60AAP W60LAP W72ABP W72LBP Cooling Capacity BTUH 22,400 27,0 33,0 37,800 43,700 50,00 64,700 Cooling Capacity KW EER pecifications 22,400 Btuh (6.56 KW) 33,0 Btuh (9.75 KW) MODEL W24AAPD W24AAPF W24LAPF WAAPD WAAPF WLAPF W36AAPD W36AAPE W36AAPF W36LAPF Electrical Rating 50 Hz 240/220-45/380-3 j 240/220-45/380-3 j 240/ / /380-3 j Operating Voltage Range Compressor--Circuit A Voltage 240/220 45/ /220 45/ / /200 45/380 Rated Load Amps 7.9/9. 3.7/4.3 8./9.2 3./3.6 2/ /. 4.5/5. Branch Circuit election Current Lock Rotor Amps 60/60 28/28 67/67 38/38 87/87 95/95 46/46 Compressor Type croll croll croll croll croll croll croll Fan Motor & Condenser Fan Motor--HP--RPM /5-090 /5-090 /5-075 /5-075 /5-075 /5-075 /5-075 Fan Motor--Amps Fan--DIA m 3 /s 458/ / / / / / /0.83 Blower Motor & Evap. Blower Motor--HP-RPM-PD /6-00- /6-00- / / / / / Blower Motor--Amps m 3 /s Cooling & E..P. (pa) w/filter (Rated- ) 0.32/ / /2 0.39/2 0.43/ / /75 Filter izes (mm) TD. 405x6x25 405x6x25 405x765x25 405x765x25 405x765x25 405x765x25 405x765x25 Basic Unit Weight-LB. (Kg) 3 (50) 3 (50) 345 (57) 345 (57) 372 (69) 372 (69) 372 (69) Barometric Fresh Air Damper 3.5 (.588) 3.5 (.588) 4.0 (.84) 4.0 (.84) 4.0 (.84) 4.0 (.84) 4.0 (.84) Blank-Off Plate.0 (0.454).0 (0.454).0 (0.454).0 (0.454).0 (0.454).0 (0.454).0 (0.454) Economizer 69.0 (3.) 69.0 (3.) 75.0 (34.02) 75.0 (34.02) 75.0 (34.02) 75.0 (34.02) 75.0 (34.02) hipping Weight --LB. (Kg) 40 (86) 40 (86) 360 (63) 360 (63) 385 (75) 385 (75) 385 (75) pecifications 37,800 Btuh (.07 KW) 64,700 Btuh (8.95 KW) MODEL Page 2 of 4 W42AAPE W42AAPF W42LAPF W48AAPE W48AAPF W48LAPF W60AAPE W60AAPF W60LAPF W72ABPF W72LBPF Electrical Rating 50 Hz 220/ /380-3 j 220/ /380-3 j 220/ /380-3 j 45/380-3 j Operating Voltage Range Compressor--Circuit A Voltage 220/200 45/ /200 45/ /200 45/380 45/380 Rated Load Amps 0.2/.4 4.6/5. 7.3/9.6 5./ /5.8 7./ /8.8 Branch Circuit election Current Lock Rotor Amps 80.7/ /43 94/94 52/52 / 54/54 74/74 Compressor Type croll croll croll croll Recip. Recip. croll Fan Motor & Condenser Fan Motor--HP--RPM /3-825 /3-825 /3-825 /3-825 /3-825 /3-825 /3-950 Fan Motor--Amps Fan--DIA m 3 /s 60/.0 60/.0 60/.3 60/.3 60/.7 60/.7 60/.5 Blower Motor & Evap. Blower Motor--HP-RPM-PD / / / / / / /4-0-2 Blower Motor--Amps m 3 /s Cooling & E..P. (pa) w/filter (Rated- ) 0.5/00 0.5/ / / / / /62 Filter izes (mm) TD. 508x765x25 508x765x25 508x765x25 508x765x25 508x765x25 508x765x25 508x765x25 Basic Unit Weight-LB. (Kg) 460 (209) 460 (209) 470 (23) 470 (23) 537 (244) 537 (244) 537 (244) Barometric Fresh Air Damper 4.5 (2.04) 4.5 (2.04) 4.5 (2.04) 4.5 (2.04) 4.5 (2.04) 4.5 (2.04) 4.5 (2.04) Blank-Off Plate.0 (0.454).0 (0.454).0 (0.454).0 (0.454).0 (0.454).0 (0.454).0 (0.454) Economizer 9.5 (4.50) 9.5 (4.50) 9.5 (4.50) 9.5 (4.50) 9.5 (4.50) 9.5 (4.50) 9.5 (4.50) hipping Weight --LB. (Kg) 475 (25) 475 (25) 485 (220) 485 (220) 550 (250) 550 (250) 550 (250) j 45/380-3 electrical ratings are 3-phase wye (star) systems requiring three (3) phase legs plus neutral and ground. NOTE: The indoor & outdoor motors and 24V transformer primary are connected at 240V derived from one () phase leg to neutral. This is internally connected and no field wiring required.

3 Cooling Application Data - Outdoor Temperature k Btuh (KW) Model W24AAP W24LAP WAAP WLAP W36AAP W36LAP W42AAP W42LAP W48AAP W48LAP W60AAP W60LAP W72ABP W72LBP Return Air (DB/WB) l 75/62 F (23.9/6.7 C) 80/67 F (26.7/9.4 C) 85/72 F (29.4/22.2 C) 75/62 F (23.9/6.7 C) 80/67 F (26.7/9.4 C) 85/72 F (29.4/22.2 C) 75/62 F (23.9/6.7 C) 80/67 F (26.7/9.4 C) 85/72 F (29.4/22.2 C) 75/62 F (23.9/6.7 C) 80/67 F (26.7/9.4 C) 85/72 F (29.4/22.2 C) 75/62 F (23.9/6.7 C) 80/67 F (26.7/9.4 C) 85/72 F (29.4/22.2 C) 75/62 F (23.9/6.7 C) 80/67 F (26.7/9.4 C) 85/72 F (29.4/22.2 C) 75/62 F (23.9/6.7 C) 80/67 F (26.7/9.4 C) 85/72 F (29.4/22.2 C) Cooling Capacity 75 F (23.9 C) (7.44) 9900 (5.83) 2700 (7.94) 90 (5.65) 320 (9.46) 9800 (5.80) (8.67) 220 (6.53) 3600 (9.25) 2500 (6.) (.04) 2200 (6.47) (0.54) (7.76) (.25) (7.53) (3.38) 260 (7.70) (.63) 900 (9.05) (2.42) 000 (8.79) (4.79) 700 (8.99) (3.47) 0 (0.34) 4900 (4.38) (0.02) (7.3) 000 (0.25) (7.54) (3.36) (8.7) 440 (2.97) 7600 (22.29) (3.3) (9.68) (4.82) 7800 (2.03) 4900 (4.38) (25.04) 500 (4.73) Below 65 F (8.3C), unit requires a factory or field installed low ambient control. k Outdoor temperatures given are for air entering condenser section inlets. Follow clearances given to ensure proper condenser airflow. l Return air temperature F. 85 F (29.4 C) (6.50) 7900 (5.24) (7.20) 7700 (5.8) 280 (8.29) 7800 (5.2) (7.76) 2000 (6.5) (8.6) (6.06) (9.90) (6.09) 3200 (9.40) (7.26) 600 (0.43) (7.8) (.98) (7.20) (0.6) (8.6) (.77) (8.55) (3.53) (8.6) 4900 (2.27) (9.84) (3.65) 330 (9.75) 500 (5.67) (9.78) 50 (5.55) (2.45) (7.25) (2.) (9.83) (2.36) 6700 (8.07) (3.97) (20.09) 470 (3.85) (23.08) (3.9) 95 F (.0 C) 2900 (6.42) 6500 (4.83) (6.56) 6600 (4.86) (7.32) 6200 (4.74) (6.97) 9700 (5.77) 270 (8.00) 9900 (5.83) 400 (8.90) 9500 (5.7) (8.46) 230 (6.82) 330 (9.73) 200 (6.88) (0.8) 20 (6.77) 300 (9.66) (8.26) (.07) (8.32) (2.3) (8.7) 3800 (.6) 3200 (9.40) (2.8) (9.49) (4.23) 3700 (9.28) (3.7) (.54) 5000 (4.68) (.63) (7.48) (.42) 560 (6.49) 4500 (3.2) (8.95) (3.33) 7800 (2.03) (3.06) 05 F (40.6 C) 7700 (5.8) 5500 (4.54) (6.09) 5900 (4.66) (6.56) 5000 (4.39) 2600 (6.33) 8800 (5.5) (7.44) 90 (5.65) (8.02) 80 (5.36) (7.73) 220 (6.53) 3200 (9.4) (6.68) (9.84) 2800 (6.38) 000 (8.79) (7.88) 400 (0.37) (8.05) (.9) 260 (7.7) (0.3) 400 (8.90) (.95) 30 (9.7) (2.89) (8.73) 40 (2.0) (0.72) (4.23) (0.98) (5.38) 800 (0.48) 500 (4.97) (2.45) 600 (7.66) (2.77) (9.04) 4600 (2.8) Capacity Multiplier Factors 5 F (46. C) 6200 (4.74) 5000 (4.39) 9400 (5.68) 5500 (4.54) (5.97) 4200 (4.6) 9600 (5.74) 7900 (5.24) 200 (6.88) 8600 (5.45) (7.23) 7200 (5.04) (7.5) 2400 (6.27) (8.6) 220 (6.53) 900 (9.05) (6.00) (7.97) (7.50) (9.55) (7.79) 340 (0.05) (7.8) 3400 (9.20) (8.49) (.04) 200 (8.84) (.6) (8.4) 3600 (0.57) (9.96) (2.7) 400 (0.37) (3.33) (9.52) (3.44) 400 (.8) 550 (6.20) 4900 (2.27) 5800 (7.02) (.3) 25 F (5.7 C) 5200 (4.45) 4500 (4.25) 8400 (5.39) 5500 (4.54) 9000 (5.56) 3800 (4.04) 7900 (5.24) 7200 (5.04) 2800 (6.38) 8200 (5.33) (6.56) 600 (4.72) 200 (6.74) (6.2) (8.20) (6.44) (8.43) 9400 (5.68) (7.8) 240 (7.2) (8.73) (7.50) 700 (8.99) (6.65) 280 (8.29) (8.02) (0.07) (8.46) 400 (0.37) (7.5) 3200 (9.4) (9.43) (.3) 330 (9.75) 3900 (.45) (8.6) (.95) 380 (.22) (4.56) 400 (.80) 5200 (5.) 600 (0.43) % of Rated Airflow -0 Rated +0 Total BTUH ensible BTUH Unit Charge Rates - R40A UNIT td. Unit - Lbs. Dehum. Units - Lbs. W24AAP/LAP - 0 EER Right & Left A/C 4.25 N/A WAAP/LAP - 0 EER Right & Left A/C N/A W36AAP/LAP - 0 EER Right & Left A/C N/A W42AAP/LAP - 0 EER Right & Left A/C N/A W48AAP/LAP - 0 EER Right & Left A/C N/A W60AAP/LAP - 0 EER Right & Left A/C N/A W72ABP/LBP - 0 EER Right & Left A/C N/A Page 3 of 4

4 Electrical pecifications MODEL W24AAPD0Z D05 D08 W24AAP/LAPF0Z F05 WAAPD0Z D05 D0 WAAPF0Z F07 F2 W36AAPD0Z D05 D0 W36AAPE0Z E06 E2 W36AAP/LAPF0Z F07 F2 W42AAPE0Z E09 E5 W42AAP/LAPF0Z F07 F4 W48AAPE0Z E09 E5 W48AAPE0Z E09 E5 W48AAP/LAPF0Z F07 F4 W60AAPE0Z E09 E5 W60AAP/LAPF0Z F07 F4 W72ABP/LBPF0Z F07 F4 Rated Volts & Phase Operating Voltage Range 240/ /380-3 l / /380-3 l / / /380-3 l / /380-3 l / / /380-3 l / /380-3 l /380-3 l No. Field Power Circuits k Minimum Circuit Amps j Maximum External Fuse or Circuit Breaker Maximum size of the time delay fuse or D rated circuit breaker for protection of field wiring conductors. k These Minimum Circuit Amp values are to be used for sizing the field power conductors. l 45/380-3 Electrical Ratings are 3-phase wye (star) systems requiring three (3) phase legs plus neutral and ground. NOTE: The indoor and outdoor motors and 24V transformer primary are connected at 240V derived from one () phase leg to neutral. This is internally connected and no field wiring required. NOTE: All wiring must conform to NIC/EIC latest edition. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses & conductor wires in accordance with the National Electrical Code & all local codes. Electric Heat Table - Refer to Electrical pecifications for Availability by Unit Model Model W24AAPD W24AAPF W24LAPF WAAPD W36AAPD W36AAPE WAAPF W36AAPF W36LAPF W42AAPE W48AAPE W60AAPE W42AAPF, W42LAPF W48AAPF, W48LAPF W60AAPF, W60LAPF W72ABPF, W72LBPF KW 240V- 220V- 45V-3 380V-3 240V- 220V- 220V-3 200V-3 45V-3 380V-3 220V-3 200V-3 45V-3 380V Nominal Heater KW based on unit model number. Page 4 of 4

5 Indoor Blower Performance - CFM (m 3 /s) at 220 Volts peed W24 W W36 W42 W48 W60 W72 ingle High Low High Low High Low High Low High Low High Medium Low EP (Inch H20) (Pa) 0.0 (0) 840 (0.4) 80 (0.38) 200 (0.57) 45 (0.54) 780 ( (0.36) 60 (0.55) 085 (0.5) 800 (0.38) 795 (0.38) 645 (0.78) 60 (0.76) 495 (0.7) (0.78) 60 (0.76) 455 (0.69) (0.82) 670 (0.79) 280 (0.60) 20 (0.57) 870 (0.88) 790 (0.84) 720 (0.8) 670 (0.79) 655 (0.78) 600 (0.76) 0. (25) 795 (0.38) 770 (0.36) 50 (0.54) 095 (0.52) 770 (0.36) 765 (0.36) 0 (0.52) 045 (0.49) 780 (0.37) 770 (0.36) 580 (0.75) 560 (0.74) (0.64) 585 (0.75) 550 (0.73) 390 (0.66) 340 (0.63) 695 (0.80) 625 (0.77) 2 (0.58) 60 (0.55) 85 (0.86) 740 (0.82) 670 (0.79) 6 (0.77) 620 (0.76) 550 (0.73) 0.2 (50) 750 (0.) 720 (0.34) 085 (0.5) 0 (0.49) 765 (0.36) 755 (0.36) 050 (0.50) 985 (0.46) 750 (0.) 740 (0.) 50 (0.7) 460 (0.69) 340 (0.63) 0 (0.6) 50 (0.7) 470 (0.69) 3 (0.63) 280 (0.60) 6 (0.77) 565 (0.74) 60 (0.55) 090 (0.5) 755 (0.83) 690 (0.80) 625 (0.77) 590 (0.75) 565 (0.74) 55 (0.72) 0.3 (75) 695 (0.33) 665 (0.3) 05 (0.48) 955 (0.45) 745 (0.) 7 (0.34) 980 (0.46) 95 (0.43) 75 (0.34) 705 (0.33) 440 (0.68) 380 (0.65) 270 (0.60) 205 (0.57) 4 3 (0.63) 245 (0.59) 85 (0.56) 575 (0.74) 495 (0.7) 080 (0.5) 05 (0.48) 700 (0.80) 6 (0.77) 590 (0.75) 550 (0.73) 525 (0.72) 480 (0.70) 0.4 (00) 625 (0.29) 600 (0.28) 9 (0.44) 875 (0.4) 705 (0.33) 690 (0.33) 895 (0.42) 840 (0.40) 665 (0.3) 650 (0.3) 340 (0.63) 0 (0.6) 85 (0.56) 20 (0.53) 5 (0.62) 245 (0.59) 40 (0.54) 095 (0.52) 495 (0.7) (0.48) 955 (0.45) 650 (0.78) 595 (0.75) 545 (0.73) 505 (0.7) 475 (0.70) (25) 5 (0.25) 505 (0.24) 845 (0.4) 790 (0.37) 650 (0.3) 625 (0.29) 805 (0.38) 745 (0.) 585 (0.28) 565 (0.27) 255 (0.59) 45 (0.54) 95 (0.43) 8 (0.39) 80 (0.56) 990 (0.47) 890 (0.42) 855 (0.40) 45 3 (0.63) 920 (0.43) 890 (0.42) 600 (0.76) 540 (0.73) 500 (0.7) 465 (0.69) (0.63) Above data is with " (25mm) standard disposable filter and " (25mm) washable filter. For optional 2" (5mm) pleated filter - reduce EP by.5" (37.33Pa). ee installation instructions for maximum EP information on various KW application. peeds marked bold above are Factory Connected. Page 5 of 4

6 Clearances - Inches (mm) Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE W24AAP, WAAP, W36AAP 5" (380) 20" (50) W42AAP, W48AAP, W60AAP, W72ABP 20" (50) 20" (50) Minimum Clearances - Inches (mm) Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET (m) CABINET W24AAP 0" 0" WAAP, W36AAP /4" (6.) 0" W42AAP, W48AAP, W60AAP, W72ABP /4" (6.) 0" Refer to the Installation Manual for more detailed information. Dimensions of Basic Unit for Architectural & Installation Requirements - Inches (mm) MODEL W24AAP WAAP W36AAP W42AAP W48AAP W60AAP W72ABP WIDTH (W) 33.0 (845) (970) (069) (069) DEPTH (D) 7.25 (4) 7.25 (4) (570) (570) HEIGHT (H) (894) (894) (256) (2362) UPPLY RETURN A B C B E F G I J K L M N O P Q R T (200) (505) (2) (505) (889) (200) (708) (3) (708) (06) (25) (759) (403) (759) (5) (25) (759) (403) (759) (5) 0.88 (276) 0.88 (276) 3.56 (344) 3.56 (344) (756) (522) (78) (84) (845) (756) (455) (78) (832) (845) (804) (762) (8) (684) (88) (940) (762) (037) (89) (087) 3.00 (787) 3.00 (787) (824) (0) 2.63 (67) 2.75 (0) 3.37 (86) 3.37 (86) 34.3 (867) 39.3 (994) (662) (679) (092) (607) (092) (787) 0.55 (268) 9.4 (232) 0.00 (254) 0.00 (254) 4.9 (06) 4.9 (06).44 (37).44 (37) 2.00 (5) 2.00 (5) 6.00 (406) 6.00 (406) 9.00 (229) 9.00 (229).88 (48) 0.00 (254) W24AAP - W72ABP Models W Hood for ECON models only Built In Rain Hood 4 Pitch Heater Access Panel Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) D A I ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location E O upply Air Opening B.44 R 5.88 F G Filter Access Panel Ventilation Air Condenser Air Outlet tandard flush vent door for non- ERV/CRV Econ. models 7.00 Low Voltage Electrical Entrance High Voltage Electrical Entrance Cond. Air Inlet J C K H Optional Electrical Entrances L M P Return Air Opening T Front View ide View Drain N Q Back View Bottom Installation Bracket MI-3889 Not used when WECO Economizers installed. Filter access is through the WECO hood. Page 6 of 4

7 Clearances - Inches (mm) Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE W24LAP, WLAP, W36LAP 20" (380) 5" (50) W42LAP, W48LAP, W60LAP, W72LBP 20" (50) 20" (50) Minimum Clearances - Inches (mm) Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET (m) CABINET W24LAP 0" 0" WLAP, W36LAP /4" (6.) 0" W42LAP, W48LAP, W60LAP, W72LBP /4" (6.) 0" Refer to the Installation Manual for more detailed information. Dimensions of Basic Unit for Architectural & Installation Requirements - Inches (mm) MODEL W24LAP WLAP W36LAP W42LAP W48LAP W60LAP W72LBP WIDTH (W) 33.0 (845) (970) (069) (069) DEPTH (D) 7.25 (4) 7.25 (4) (570) (570) HEIGHT (H) (894) (894) (256) (2362) UPPLY RETURN A B C B E F G I J K L M N O P Q R T (200) (505) (2) (505) (889) (200) (708) (3) (708) (06) (25) (759) (403) (759) (5) (25) (759) (403) (759) (5) 0.88 (276) 0.88 (276) 3.56 (344) 3.56 (344) (756) (522) (78) (84) (845) (756) (455) (78) (832) (845) (804) (762) (8) (684) (88) (940) (762) (037) (89) (087) 3.00 (787) 3.00 (787) (824) (0) 2.63 (67) 2.75 (0) 3.37 (86) 3.37 (86) 34.3 (867) 39.3 (994) (662) (679) (092) (607) (092) (787) 0.55 (268) 9.4 (232) 0.00 (254) 0.00 (254) 4.9 (06) 4.9 (06).44 (37).44 (37) 2.00 (5) 2.00 (5) 6.00 (406) 6.00 (406) 9.00 (229) 9.00 (229).88 (48) 0.00 (254) W24LAP - W72LBP Models R Built In Electric E Rain Hood Heat Heater O 4 Pitch Access.44 Panel D C. Breaker/ W 2.3 Disconnect upply Air Opening B ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location A I.250 Access Panel (Lockable) tandard flush vent door for non-erv/crv Econ. models Hood for ECON models only Return Air Opening Optional Electrical Entrances C Filter Access Panel Ventilation Air 5.88 F T Drain Bottom Installation Bracket Back View Q P M N L H K J Cond. Air Inlet ide View Low Voltage Electrical Entrance High Voltage Electrical Entrance Condenser Air Outlet Front View G MI-3890 Not used when WECO Economizers installed. Filter access is through the WECO hood. Page 7 of 4

8 MULTI-TEC Control equence of Operation & Logic The MULTI-TEC unit PLC logic board uses a technologically advanced series of sequences to control unit operation. These sequences can be defined in the following processes: Alarm Logic Indoor Blower Control Temperature Control Free Cooling Operation Compressor Logic The processes listed are described in detail below. Alarm Logic High Mixed Air Alarm If the mixed air temperature sensor is above cooling temperature setpoint for longer than 0 seconds, the wall unit will generate a high mixed air alarm. Low Mixed Air Alarm If the mixed air temperature sensor is below 50 F for longer than 0 seconds, the wall unit will generate a low mixed air alarm. Refrigerant Low Pressure When the low pressure switch indicates a low pressure condition and there is an active call for cooling, the controller will generate an alarm after a delay. The delay used by the low pressure alarm is determined by the outdoor air temperature. If the outdoor air temperature is below 55 F, the delay is 80 seconds. If the outdoor temperature is above 55 F, the delay is 20 seconds. Additionally, if the outdoor temperature sensor is not used, the delay is set to 80 seconds. The controller will try to run the refrigeration system three (3) times before the alarm will lock the compressor out. Economizer Damper: When the controller commands the economizer damper actuator to a position other than 0% and the damper switch indicates the damper is not open after a delay of 20 seconds, the controller will generate a damper failed to open alarm. When the controller commands the economizer damper actuator to the 0% position and the damper switch indicates the damper is not closed after a delay of 0 seconds, the controller will generate a damper failed to close alarm. Freeze tat Alarm: When the coil temperature is below F for longer than 20 seconds, the controller will generate a freeze stat alarm. This will then change the blower to high speed and turn off the compressor for 0 seconds or reset once the temperature has reached 25 F above the freeze stat temperature set point. Fan tatus Alarm If the fan is commanded on and the fan status switch has not indicated the fan is running within 45 seconds, the system will generate and alarm. Page 8 of 4

9 Indoor Blower Control The fan will be enabled if the system is set for continuous blower, economizer enabled, cooling stage, cooling stage 2, heating stage, heating stage 2, freeze stat on, or a run test is started. Temperature Control Zone election Based on the zone setting (average or highest), the unit will decide which zone control temperature to use. The control temperature is an average of the zone temperature sensors and the return air temperature sensors in each zone. Cooling equence (Economizer Available) Field-Adjustable If the zone control temperature is higher than 79 F and outdoor conditions are acceptable for economizing, the unit will enable the economizer. If the zone control temperature is higher than 80 F, the unit will enable mechanical cooling stage. If the zone control temperature is higher than 8 F, the unit will enable mechanical cooling stage 2. Cooling equence (Economizer Not Available) Field-Adjustable If the zone control temperature is higher than the cooling setpoint, the unit will enable stage mechanical cooling. If the zone control temperature is higher than 80 F, the unit will enable stage 2 mechanical cooling. Heating equence: Field-Adjustable If the zone control temperature is below 58 F, the unit will enable electric heat stage. If the zone control temperature is below 57 F, the unit will enable electric heat stage 2. If the zone control temperature is below 56 F, the unit will enable electric heat stage 3. Free Cooling Operation Economizer Enable The economizer will be enabled for cooling operation if the following conditions are true: None Economizer will not be enabled. Bulb Only Field-Adjustable. Outdoor air temperature is below 70 F. 2. Indoor zone relative humidity is below 70% (with LC only). Temperature & Humidity Field-Adjustable. Outdoor air temperature is below 70 F. 2. Outdoor relative humidity is below 60% (without LC indoor zone humidity sensor) or 80% (with LC indoor humidity sensor). 3. Indoor zone relative humidity is below 70% (with LC indoor RH sensor only). Enthalpy (Temperature, Humidity & Dewpoint) Field-Adjustable. Outdoor air temperature is below 70 F. 2. Outdoor relative humidity is below 60% (without LC indoor zone humidity sensor) or 80% (with LC indoor humidity sensor). 3. The outdoor air dewpoint is less than 60 F. 4. Indoor zone relative humidity is below 70% (with LC indoor RH sensor only). Compressor Logic Enable The compressor will be enabled when stage is enabled and outdoor air conditions are not acceptable for economizing. If the conditions are acceptable, the compressor will run when stage 2 is enabled. Delays & Run Time Field-Adjustable The compressor will have a minimum run time of 60 seconds and a minimum off time of 20 seconds. Page 9 of 4

10 Page 0 of 4 This page intentionally left blank.

11 tandard & Optional Accessory Functionality LC6000 Controller: The LC6000 is Bard s premier control device for electronics shelters, equipment buildings, pump houses and modular buildings. A logic board inside the LC controller communicates with logic boards in the MULTI-TEC units to decide when to cool the area, and what mode of cooling to use if economizers are installed. Cooling modes include unit rotation and intuitive load balancing. Energy efficiency and consistent area temperature control are maximized for reliable equipment cooling. Humidity monitoring inside the shelter helps reduce the chance of condensation forming on equipment and electronics and can be controlled with optional equipment. An N+ ( extra backup unit) operation or a localized load-based strategy can be used for better temperature control when using multiple units. The controller is able to be installed in any area inside the structure with the use of remote temperature sensors, and can operate with 3 separate zones or areas including office spaces and battery rooms. th-tune Controller ( ): The th-tune controller can be used to operate one unit independent of the LC controller. The th-tune acts as a simple thermostat and connects to one unit using standard 8 Ga. twisted pair wiring. The TEC-EYE service tool (provided in the kit) is used to program and setup the MULTI-TEC unit. The th-tune controller does not connect to the LC controller and does not have remote alarming capability. EMI Ferrite Filter (8-055): An EMI filter is used to suppress interference that may be present on the connecting (2) wire twisted pair between the MULTI-TEC units and LC controller. When connecting all units together in series through a daisy chain connection, a total of (2) EMI filters are needed. One filter is placed at the 2 wire connection to the LC controller. The other filter is placed at the 2 wire connection point where the unit at the end of the chain is connected. If two separate daisy chain connections are made, a total of (2) EMI filters are needed, one EMI filter is needed at the 2 wire connection point of each end unit. TEC-EYE ervice Tool (8-059): The TEC-EYE service tool is used for system setup and troubleshooting. An easy to read backlit display and 6-button control is provided. Used as a display and interface, the tool is able to interact with the microprocessor on the logic board located in the LC controller and in the MULTI-TEC unit. A 5 foot communication cable with RJ connectors is provided with the TEC-EYE. (Included with every LC6000 & th-tune control package.) VDC moke Detector (8-060): The smoke detector has a thermal sensor set to F and has dual color LED indicator lights to display status. Required equipment includes a 3.5" or 4" octagonal, single gang, or a 4" square back box with a plaster ring to be directly mounted to a ceiling. Wiring used must be 4-22AWG and there are 4 connection points. moke detector can be wired into the LC6000 or directly into a MULTI-TEC unit. VDC Hydrogen Detector (8-06): The hydrogen gas detector is designed for battery rooms and shelters. It is able to detect hydrogen gas as low as % volume and operate a wall mount economizer equipped unit to ventilate the structure. At a 2% volume, a warning alarm will be activated and an alarm signal is sent to the LC controller. A test button allows for alarm testing. Use 8 Ga. JT 3 conductor PVC jacketed cable for power connection to LC controller (field supplied). Detector can be installed directly to a wall, ceiling or conduit box. Page of 4

12 MULTI-TEC Unit Controllers MODEL Controller Logic Voltage hipping English panish French Fahrenheit Weight Celsius No. of Units Controlled Unit moke Zones Models Detector Unit Connection Remote Communication & Diagnostics LC6000 PLC 20V/2V-240V 50/60 Hz AC 23 lbs. Yes No Yes Yes/Yes 4 WA with PLC 3 Yes Daisy Chain Daisy Chain th-tune Controller # PLC 24V lb. Yes No Yes Yes/Yes WA with PLC No ingle Unit ingle Unit The LC6000 and th-tune Controller # are shipped with a TEC-EYE diagnostic tool. The th-tune Controller # does not include alarm functionality or remote communication. ystem setup requires the use of the TEC-EYE diagnostic tool. LC6000 tandard and Optional Accessories Part Number Description EMI Ferrite Filter ( needed for each unit connection to Controller) Included with LC TEC-EYE (ervice Tool), 5 ft. communication cable Remote Temperature & Humidity ensor w/' wire (2 additional sensors may be used) Remote Temperature ensor ( additional sensor may be used) Optional EMI Ferrite Filter Part #8-055 TEC-EYE Part #8-059 Controller Version Nomenclature LC LC Controller Model Controller Version Page 2 of 4

13 oftware Version Nomenclature LC LC Controller oftware Model oftware Version The Bard MULTI-TEC Wall Mount unit contains an advanced PLC logic board with on-board software similar to a computer. When buying additional MULTI-TEC Wall Mount units for an existing project, it is important for all units and the LC controller to contain the same software version. The easiest method of ensuring all the units and the LC controller have the same software is to use a laptop computer to download the latest software for the new MULTI-TEC unit or LC controller from the internet and using a MicroUB cable reprogram all existing equipment. Additional MicroUB cables can be found at most stores carrying phones and electronics equipment. Using the MicroUB Cable to Update oftware #.) Download new program from the Bard oftware Download page. #2.) Replace old program in existing equipment using Micro UB cable. oftware Website Current versions of software and/or software information for all controllers and unit equipment may be found at: Page 3 of 4

14 Air Conditioning Wall-Mount Model Nomenclature ERIE NOMINAL CAPACITY 24-2 Ton - 2½ Ton 36-3 Ton 42-3½ Ton 48-4 Ton 60-5 Ton 72-6 Ton W 36 A A P A 0 5 X X X X E A = Compressor & Controls - Right ide L = Compressor & Controls - Left ide P = PLC Logic Board Economizer REVIION A = W24 - W60 B = W72 VOLT & PHAE D - 240/220/50/ E - 220/200/50/3 F - 45/380/50/3 Ventilation ystem Packages MULTI-TEC tandard Controls MI-3757 KW VENTILATION OPTION B = Blank-Off Plate 5 = Economizer: Default Enthalpy convert to DB only FILTER OPTION X - -inch Throwaway (tandard) W - -inch Washable P - 2-inch Pleated (MERV 8) M - 2-inch Pleated (MERV ) N - 2-inch Pleated (MERV3) COLOR OPTION X - Beige (tandard) - White 4 - Buckeye Gray 5 - Desert Brown 8 - Dark Bronze A - Aluminum - tainless UPPLY AIR OUTLET X - Front (tandard) CONTROL MODULE E = LAC C = LAC & CCH (W60 includes crankcase heater as standard.) COIL OPTION X - tandard - Phenolic Coated Evaporator 2 - Phenolic Coated Condenser 3 - Phenolic Coated Evaporator and Condenser 4 - Condenser ection Component Coating, Coated Evaporator and Condenser 5 - Internal and External Cabinet Component Coating, Coated Evaporator and Condenser ECONOMIZER OPTIONAL The optional built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. tandard Features: Full rated outdoor intake Fully modulating Hi-Torque Actuator 7" intake hood with filter imple single blade design Positive shut-off with non-stick gaskets Electronic Enthalpy sensors PLC control module with precision settings and diagnostics High Pressure witch: Required afety Device that also provides protection to the compressor system when system refrigerant pressure is above an acceptable level. Auto Reset, 650 psig. Output to compressor control module. Low Pressure witch: Provides protection to the compressor when refrigerant pressure falls below an acceptable level. Auto Reset, cut out at 40 psig. Output to compressor control module. Low Ambient Control: Modulating control that removes power from the condenser fan to allow for unit compressor cooling operation at outdoor ambient temperatures below 65 F. Factory set for system performance. crew-on connection for easy servicing. Output to condenser fan motor. Compressor Control Module: Compressor protection device that has a -second to 5-minute timer. This module features a delay-on-make for initial startup for a minimum of 2 minutes plus 0% of the timer setting. There is no delay during routine operation. Allows one automatic retry after high pressure switch activation, then goes into hard lockout mode. Output to PLC logic board. tart Assist (ingle Phase Models Only): PTCR motor starting device increases compressor motor torque 2-3 times. upply Air ensor: 0K Thermistor measures supply air temperature, output to PLC logic board. Return Air ensor: 0K Thermistor measures return air temperature, output to PLC logic board. Evaporator ensor: 0K Thermistor prevents coil freezing due to low return air temperature. Output to PLC logic board. Outdoor Temperature & Enthalpy ensor: 0K Temperature sensor and 4-20mA humidity transmitter, output to PLC logic board (PLC defaults to temperature only). Phase Monitor (3-Phase Models Only): Prevents 3-phase compressor operation to protect the compressor if the device senses incorrect phasing. LED indicator light. Filter witch: Adjustable switch to indicate the unit air filter needs to be replaced. Output to PLC logic board. MULTI-TEC Optional Controls Compressor Crankcase Heater: 2-wire heater that prevents refrigerant migration and mixing with crankcase oil when the unit is off, prevents condensation of refrigerant in the crankcase of the compressor, and keeps refrigerant at a temperature higher than the coldest part of the system. Recommended for Canada and cold climate compressor operation. Page 4 of 4 Bard Manufacturing Company, Inc. Bryan, Ohio Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. 47 March 208 upersedes: 67

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

THE WALL-MOUNT AIR CONDITIONERS (50HZ) THE WALL-MOUNT AIR CONDITIONER (50HZ) Models W24A2 to W70A2 Right ide Control Panel Models W24L2 to W70L2 Left ide Control Panel 2,600 Btuh (6.33 KW) 62,000 Btuh (8.6 KW) For Export Only The Bard Wall-Mount

More information

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC00 controller. When installed with an optional 0%

More information

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D35A/L 1-tage Right & Left-Hand Control Panel The Bard DUAL-TEC Wall Mount Air Conditioners with -48VDC Blower

More information

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D36A/L 1-tage Right & Left-Hand Control Panel Green Refrigerant R-410A The Bard DUAL-TEC Wall Mount Air Conditioners

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER - 9. EER, (HZ) Model W7A2 Right-ide Control Panel Model W7L2 Left-ide Control Panel Ton (, Btuh) For Export Only The Bard Wall-Mount Air Conditioner is a self contained energy

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models W7A to W7A Right-ide Control Panel Models W7L to W7L Left-ide Control Panel. to Ton (, to, Btuh) The Bard Wall-Mount Air Conditioner is a self contained

More information

WALL-MOUNT HEAT PUMPS - (60HZ)

WALL-MOUNT HEAT PUMPS - (60HZ) WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models WAA to W72AA Right-ide Control Panel Models WLA to W72LA Left-ide Control Panel. to Ton (7, to 7, Btuh) Green Refrigerant R-A The Bard Wall-Mount Air

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to,000 Capacities:,00 to,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which

More information

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

THE WALL-MOUNT Quiet Climate A/C 10.0 EER THE WALL-MOUNT Quiet Climate A/C. EER Models WA, W9A, WA to Ton (, to, Btuh) Right Side Control Panel Hz GREEN REFRIGERANT R-A The Bard Wall-Mount Air Conditioner is a self contained energy efficient system,

More information

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

THE WALL-MOUNT TM SIX TON AIR CONDITIONER The Bard Wall-Mount Six Ton Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or

More information

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant The Wall-Mount Variable Environmental Control Units Bard is an ISO 00:200 Certified Manufacturer, 5 and -Ton Variable ECU Dual /50 Hz Frequency Cooling Op Range -40F to +F ODT The Bard Variable ECU design

More information

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models Models: W24G3 to WG3 Up to 1.5 EER 26, to 57,5 BTUH Cooling Capacity 37, to 74, BTUH Heating Capacity The Bard Wall-Mount Electric Air Conditioner with gas fired heating is a self contained energy efficient

More information

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS Models: SH to SH Up to.5 EER Heating Capacities: 2, to, BTUH Cooling Capacities: 2, to 55, BTUH Green Refrigerant R-A The Bard Wall-Mount Heat Pump is a self-contained

More information

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 5.3 BTU/WATT WA3S WA5S Right Side Control Panel WL3S WL5S Left Side Control Panel 3 to 5 Ton (35,2 to 5,5

More information

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models WG3S2, WG4S2, WG5S2 6HZ 24, to 56,5 BTUH Cooling Capacity 37,

More information

THE WALL-MOUNT HEAT PUMPS EER, (60HZ)

THE WALL-MOUNT HEAT PUMPS EER, (60HZ) THE WALL-MOUNT HEAT PUMPS -. EER, (HZ) Models: Heating Capacities: Cooling Capacities: Engineered Features WHA to WHA Hz (,5 to 5,5 Btuh) (7, to 5, Btuh) The Bard Wall-Mount Heat Pump is a self contained

More information

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES 180-300 INGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNIT 15-25 NOMINAL TON ubmittal Data DECRIPTION The units are one -piece electric cooling/optional electric heating units, prewired and precharged.

More information

Q-TEC QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner Cooling Capacities: 13,3 to 49,3 BTUH (Based on EWT, GPM & CFM) Q-TEC QC-Series Chilled Water Air Conditioner The Q-TEC Series self-contained packaged chilled water air conditioner is designed to be installed

More information

Q-TEC Q24A-Q60A Air Conditioners

Q-TEC Q24A-Q60A Air Conditioners The Q-TEC Series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q-TEC s design provides whisper quiet operation with total

More information

THE WALL-MOUNT 6-TON AIR CONDITIONERS

THE WALL-MOUNT 6-TON AIR CONDITIONERS THE WLL-MOUNT -TON IR CONDITIONERS Model W7 - Right Side Control Panel Model W7L - Left Side Control Panel, Btuh 9.5 EER Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system,

More information

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB BARD MANUFACTURING COMPANY, INC. W18AA-W72AB Series Right-Side Access Air Conditioner W18LA-W72LB Series Left-Side Access Air Conditioner Engineering Specification Guide 1.0 GENERAL Furnish and install

More information

Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-Tec TM QC-Series Chilled Water Air Conditioner Q-Tec TM QC-Series Chilled Water Air Conditioner Cooling Capacities:, to, BTUH (Based on EWT, GPM and ) The Q-Tec Series self-contained packaged chilled water air conditioner is designed to be installed

More information

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units Heating Capacities: Cooling Capacities: Q-TEC Q2H3-QH3 Air-to-Air Heat Pump 0 EER Units 23,0 to,000 Btuh,000 to 5,0 Btuh The Q-TEC Series self contained packaged heat pump is designed to be installed inside

More information

Product Guide. Wallmount. Air Conditioners & Heat Pumps

Product Guide. Wallmount. Air Conditioners & Heat Pumps Product Guide Wallmount Air Conditioners & Heat Pumps Standard Features page 2 All Major Components can be Accessed from the Front 00 Hour Salt Spray rated powder coated baked paint finish AHRI certified

More information

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WALLMOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To. BTU/WATT WAS, WAS, WAS to Ton (,0 to,00 Btuh) Right Side Control Panel 0Hz GREEN REFRIGERANT RA The Bard

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WLL-MOUNT IR CONDITIONERS -. EER, (HZ) Models W7 to W. to Ton (, to, Btuh) Right Side Control Panel Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed

More information

LC6000 Controller used with MULTI-TEC Wall Mount Units Specification Sheet & Application Guide

LC6000 Controller used with MULTI-TEC Wall Mount Units Specification Sheet & Application Guide LC6000 Controller used with MULTI-TEC Wall Mount Units Specification Sheet & Application Guide FEATURES OF THE LC6000 CONTROLLER Control up to 14 units with a single LC6000 controller. Complete control

More information

General Description. Operation

General Description. Operation ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A PH-SERIES PCKGED HET PUMPS Cooling Capacities: 2, to 6, Heating Capacities:, to 2, SEER:. HSPF: GREEN REFRIGERNT R-4 FRONT (INDOOR IRFLOW) END OF UNIT CK (OUTDOOR IRFLOW) END OF UNIT Standard Engineered

More information

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners Bard Manufacturing's revolutionary MEGA-TEC WALL-MOUNT sets the industry standard for flexibility. Engineered to cool virtually any equipment building

More information

Installation Instructions

Installation Instructions Installation Instructions Wall Mounted Packaged Air Conditioner Models: WA8, WA24 MIS-656 Bard Manufacturing Company Bryan, Ohio 43506 Since 94...Moving ahead, just as planned. Manual No.: 20-200K Supersedes:

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-234 G Supersedes: 2100-234

More information

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP12-20-24-30-36-42-48-60-72 General

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA3 WA42 WA42 WA49 WA2 Bard Manufacturing Company Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 20-2J Supersedes:

More information

BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner

BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner Bard High Sensible Cooling Systems HR36 Series 12.5 EER 2 to 3 Ton HR58 Series 11.0 EER 3.5 to 5 Ton The FUSION-TEC TM has been

More information

General Description. Safety Listed

General Description. Safety Listed ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 Ton) Vertical Wall Mount Air Conditioners General Description Industrial Climate Engineering s air conditioners are used primarily

More information

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air

More information

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,

More information

General Description. Safety Listed

General Description. Safety Listed ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 Ton) Vertical Wall Mount Air Conditioners General Description Industrial Climate Engineering s air conditioners are used primarily

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA3 WA43 WA44 WA49 WA Bard Manufacturing Company Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 0-39 Supersedes:

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

PRODUCT DATA SHEET. Models ASDCA/HSDCA & ASDCHA

PRODUCT DATA SHEET. Models ASDCA/HSDCA & ASDCHA PRODUCT DATA SHEET DC Free Air HVAC Unit w/48 VDC Evaporator Fan Motor, 00% Free Cooling and CoolLinks Controller Models ASDCA/HSDCA36-42-48-60-72 & ASDCHA36-42-48-60 General Description The Marvair ComPac

More information

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Wall Mounted Air Conditioners with Gas Heat Models AVGA PRODUCT DATA SHEET Wall Mounted Air Conditioners with Gas Heat Models AVGA24-30-36-42-48-60 General Description The Marvair GPac wall mounted air conditioner with gas heat is designed for use on a variety

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps Heating Capacities: 2, to 7, BTUH Capacities:, to 2, BTUH The Q/Tec Series self-contained packaged heat pump is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec

More information

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP24-30-36-42-48-60 General Description The Marvair

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: W12A2-A W12A1-K Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual: 2100-509E Supersedes:

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGED AIR CONDITIONER HA-A HL-A Models: H6A-A H6L-A Description Page Cabinet Components HA-A, H6A-A Exploded View... Usage List HA-A... Usage List H6A-A... Cabinet

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGED AIR CONDITIONER Models: W7A2-A WA2-A W24A2-A W24A2-B W24A2-C W24A2-D W24A2-F WA2-A WA2-B WA2-C WA2-D WA2-F WA2-A WA2-B WA2-C WA2-D WA2-E WA2-F W42A2-A W42A2-B

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

2 shp 13 lc 1 36 t - 1 a

2 shp 13 lc 1 36 t - 1 a HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 016---028 Single---Package Cooling Units with Factory---Installed Optional Electric Heat Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION

More information

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( ) (N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

Q/Tec TM QA-Series Air Conditioners

Q/Tec TM QA-Series Air Conditioners Q/Tec TM QASeries Air Conditioners The Q/Tec series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec s design provides

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

10EER 7.5 Ton Vertical Wall Mount Air Conditioners Model AVHDA90 (Dual Compressor)

10EER 7.5 Ton Vertical Wall Mount Air Conditioners Model AVHDA90 (Dual Compressor) PRODUCT DATA SHEET 10 7.5 Ton Vertical Wall Mount Air Conditioners Model AVHDA90 (Dual Compressor) General Description Marvair s AVHDA ComPac air conditioners are used primarily to cool electronic and

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

62DA,DB,DC,DD,DE,DF07-38

62DA,DB,DC,DD,DE,DF07-38 62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

Q/Tec TM QW-Series Water-to-Air Heat Pumps

Q/Tec TM QW-Series Water-to-Air Heat Pumps Heating Capacities: 6,4 to 45,5 BTUH Capacities:, to 53,5 BTUH : 3. to 3.5 : 3.4 to 6.6 Q/Tec TM QW-Series Water-to-Air Heat Pumps The Q/Tec series self contained packaged water-to-air heat pump is designed

More information

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or

More information

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step- Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to 110 The Bard GEOTEC Geothermal/Water

More information

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits CommStat 4 PRODUCT DATA SHEET Controller for Redundant Telecom HVAC Systems General Description The CommStat 4 is an HVAC controller designed specifically for controlling two redundant air conditioners,

More information

ComPac I & ComPac II 2 to 6 Ton Vertical Wall Mount Air Conditioners

ComPac I & ComPac II 2 to 6 Ton Vertical Wall Mount Air Conditioners ComPac I & ComPac II 2 to 6 Ton Vertical Wall Mount Air Conditioners Models AVPA24-30-36-42-48-60-72 (Single Stage Compressor) Models HVEA24-30-36-42-49-60 (Single Stage Compressor) Models HVESA36-42-49-60

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060 40QAC / 38HDR 40QAQ / 38QRR Ceiling---uspended Duct Free plit ystem izes 018 to 060 Product Data INDUTRY LEADING FEATURE / BENEFIT AN INEXPENIVE AND CREATIVE OLUTION TO DEIGN PROBLEM. The 38HDR(QRR)/40QAC(QAQ)

More information

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT 50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA24-30-36-42-49-60 and HVPSA36-42-49-60 General Description HIGH EFFICIENCY - The Marvair Classic 13 High Efficiency Series

More information

Indoor Air Handlers with Compressors MVS and MVW

Indoor Air Handlers with Compressors MVS and MVW Indoor Air Handlers with Compressors MVS60-90-120-144 and MVW60-90-120-144 General Description The Marvair Marine self-contained water and air cooled air conditioners are designed for both new installations

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

Specifications and Performance

Specifications and Performance R35C/H Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Heat Pump (PTHP) Straight Cooling Nominal Capacities 9,000 12,000 15,000 18,000 Btuh 2.6 3.5 4.4 5.3 kw Heat Pump Nominal Capacities 9,000

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Assembly

Models: Contents. Cabinet Components. Functional Components  Exploded View... 3  Usage List Control Panel. Blower Assembly REPLACEMENT PART MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA0, WA7 General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual consists of

More information

Hazardous Location Certified

Hazardous Location Certified Certified. Not Modified. EONA2-72 and EXNDA/EONDA90-240 2,000 BTUH (3.5Kw) to 240,000 BTUH (70.3Kw) Increased Safety Vertical Wall Mount Air Conditioners General Description EXNA60 The old approach to

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information