Edition 1, From serial no Publ. no A OM B 900, Orwak Brickman 900. Operating instructions (in the original)
|
|
- Jasmine Watkins
- 5 years ago
- Views:
Transcription
1 Edition 1, From serial no Publ. no A OM B 900, Orwak Brickman 900 Operating instructions (in the original)
2 CONTENTS Safety Safety features... 3 Range of application... 3 Technical specifi cations... 4 Installation... 4 Diagram of terminal functions. 5, 9 Machine parts... 6 Prior to operation... 7 Operation... 7 Troubleshooting... 7 Setting the operating time... 8 Weekly inspection and maintenance Safety checks Transport Service CE SAFETY Please read the operating instructions BEFORE operating the machine. Our warranty/product responsibility requires that instructions are followed, and that original spare parts and recommended hydraulic oil and lubricants are used, and that no conversion or modification is carried out. The user of the machine is responsible for the safety checks, and for ensuring that daily maintenance of the machine is carried out. The user is responsible for ensuring that any faults are rectifi ed, and that neither the user nor other individuals are exposed to danger. The owner is responsible for ensuring that national and local laws are complied with when using the machine. This symbol means WARNING or DANGER personal safety instruction! The machine must not be used if the safety features (e.g. switches and protections) have been deactivated, damaged or removed. Lost or damaged parts must be replaced with original spare parts. Installation, repair and service work must only be performed by qualified and competent personnel, and in accordance with the installation and service instructions. The machine must not be used by minors. Never climb on the machine. Operators and other persons must not enter the feed hopper (A) under any circumstances. Material to be compacted should be added into the feed hopper. No tools or other means of assistance should be used when adding material into the hopper. Material should only be fed into the hopper whilst standing on the floor, i.e. no steps, pallets, stools or other means of assistance should be used to facilitate the feeding of material. The distance between where the operator is standing and the upper edge of the feed hopper should never be less than 1500 mm. The machine must never be operated without the briquette collection bin having been placed under the briquette chute (B). The machine should always be turned off when changing the collection bin. Errors and omissions excepted. 2
3 The machine must only be used if all the cover plates and caps/protective covers are in place and correctly fi tted. The electrical box (C) must be closed when the machine is connected to the mains. No work (service, repairs, disassembly, maintenance, etc.) should be carried out on the machine unless the main power switch (D) is padlocked in the off position. Always turn the main power switch off before disconnecting the mains cable for any reason. The machine and the area surrounding it should be kept clean and free of foreign objects. The machine is not intended to be placed in areas where there is a high risk of explosion. SAFETY FEATURES The machine is equipped with the following safety features: Caps/protective covers restrict access to dangerous moving parts. The machine is also equipped with two emergency stops (E), as well as a main switch (D) that can be padlocked to prevent unauthorised use, e.g. during service, cleaning and maintenance, or when removing any material that has become trapped. RANGE OF APPLICATION The machine is essentially designed to compact corrugated cardboard. However, other types of material can be compacted in the briquetting press, subject to the approval of the manufacturer. The machine must only be used in areas that have a roof, protection against wind, and normal lighting. Materials that are flammable or of an explosive nature (e.g. pressurised containers or the like) which, when exposed to pressure or sparks, could cause damage, fi re or an explosion, must not be compacted in the machine. The same also applies to compact paper material (e.g. newspapers, brochures, data lists, books, etc), metal materials, glass, wood materials, liquids, foodstuffs, plastics, rubber, minerals, chemicals and rubber, none of which should be compacted in the machine. 3
4 TECHNICAL SPECIFICATIONS (Brickman 900) INSTALLATION There should be at least 1 metre of open space around the machine. The clearance height where the machine is to be placed should be at least 30 centimetres (see Technical specifi cations). (Illustrations referred to in the text appear on the next two pages.) GENERAL DATA A 2470 mm B 2010 mm C 585 mm D 1350 mm E 1500 mm F 1870 mm G 5710 mm H 1355 mm I 695 mm J 1350 mm K 950 mm L 1180 mm M 1570 mm N 265 mm O 1035 mm P 230 mm Q 930 mm R 535 mm S 840 mm T 1960 mm U 1300 mm V 1155 mm Machine weight: Dimensions: 3200 kg Height: 2470 mm Width: 5710 mm Depth: 1960 mm Feed hopper: Depth: 930 mm Width: 1300 mm Volume: 1.5 m³ Colour: RAL 2001 (orange) Noise level: 68 db (A) ELECTRICAL DATA Operating voltage: 3x400V Control voltage 24V (DC) Mains connection: 5-pin Euro plug (32A) Fuse: 25A (delay action) Electric motor: 7.5 kw Protection class: IP 55 HYDRAULIC DATA: Working pressure: max 200 bar Press force: 250 kn Compaction pressure/cm² 62 kg Cycle time, total: 29 s Volume of oil: 160 litres Recommended oil: +5 C to +60 C: Statoil HVXA 32, or equivalent Below +5 C A special oil or a heater may be necessary at lower temperatures. Fit the briquette chute (B) (it is normally placed in the feed hopper (A) during transport) by fi rst removing the protective cover/cap (F) or cover plates on the machine. Secure the briquette chute using the four bolts and the springs (G). Replace the cover plate(s)/cap(s). Remove any transport protections between the hydraulic pump (X) and the tank. If fi tted, activate the guillotine's (4) optional lubrication cans (J). Electrical installation (should be carried out by a qualified electrician) Check the motor s (H) direction of rotation, as follows: Activating manual mode (on the terminal): - Turn the main power switch (D) on Terminal text BRICKMAN - Press F4, twice READY TO START Main menu Manual mode F1 FEED PLATE FOR- WARD F2: FEED PLATE BACK - Press the down arrow until the cursor is on Manual mode - Press Enter - Move the cursor to Feed plate - Press Enter - Press and hold F1 for 4 seconds 1. Make sure that the feed plate (I) has moved towards the cutting blades (R). 2. If no movement has occurred: turn the main power switch off and disconnect the mains cable. 3. Change the incoming phases. - Press F4 several times until "BRICKMAN READY TO START" is displayed. 4
5 DIAGRAM OF TERMINAL FUNCTIONS Use the arrow keys and confi rm with Enter. MAIN MENU: OP info Settings Manual mode Language Service Log in MANUAL MODE Press briquette out Feed plate Knife Press Brake Motor Pressure Air fan Press and hold button to operate manually. F1:BRIQUETTE OUT F1:FEEDPLATE FORW. F2:FEED PLATE BACKW F1:KNIFE UP F2:KNIFE DOWN F1:PRESS OUT F2:PRESS BACKW. F1:BRAKE UP F1:MOTOR F1:HIGH P.+MOTOR F2:HP+LP+MOTOR LANGUAGE: SERVICE: For authorised service personnel only F1:COOLING FAN For authorised service personnel only LOG IN: F1:L.in F2:L.out F3: Change password 5
6 MACHINE PARTS These illustrations are referred to by the italic text in the operating instructions. Springs (G) Feed hopper (A) Upper sensor (T) Briquette chute(b) Guillotine (Y) Cover plate (F) Emergency stop (E) Lubrication can(j) Cover plate (O) Press chamber(s) Lower sensor (Q) Cover plate (P) Guillotine (Y) (knife) Press loop/brake Cutting blade (R) Feed plate (I) Emergency stop (E) Lubrication can(j) Front sensor (Z) Cover plate (V) Electrical box (C) Rear sensor (U) Protective cover (N) Motor (H) Hydraulic pump (X) CONTROL PANEL / DISPLAY Rear sensor (Å) Start (L) Stop (M) Main power switch (D) Emergency stop (E) Reset button (K) NUM - ust be pressed and held when entering numbers. The arrow keys are used to move the cursor to the item to be selected. To see the whole the whole menu, scroll using the arrow keys. F4 - to go back through the menus. Enter confi rms the selection. 6
7 PRIOR TO OPERATION Ensure that the main power switch (D) is turned off. Make sure that there are no foreign objects in the feed hopper (A) or on or around the machine. Ensure that the collection bin has been placed under the briquette chute (B). Turn the main power switch on. Press the Reset button (K) The machine is now ready for use. OPERATION Press the start button (L). Place material into the feed hopper (A). The machine operates for a pre-set period of time and then stops. When delivered, the machine is normally set for an operating time of 2 minutes. (The operating time can be changed see the section Setting the operating time.) The machine can also be stopped by pressing the stop button (M). The machine will stop once an operation cycle has been completed, i.e. once it is in the home position, ready for new material to be fed in. If necessary, the machine can be stopped by using either of the two emergency stops (E). Rectify the situation that caused the emergency stop to be used. Reset the emergency stop by pulling it out, then press the reset button (K). FAULT FINDING (messages on the terminal screen) Check the terminal located on the machine s electrical box (C) for any error messages. If the screen is empty/there is no text: Turn the main power switch (D) off, disconnect the mains cable and open the electrical box. Check the automatic fuses in the electrical box. Check the fuses for the machine s power supply in the building s distribution box. Close the electrical box. Check that the mains cable is not damaged. Reconnect the mains cable and turn the main power switch back on. If the reset button (K) is fl ashing: Check the terminal screen for any messages. In the event of an alarm or loss of power, the machine must be reset by pressing the reset button. Terminal messages Ready to start The machine is reset and ready to start. Emergency Stop active An emergency stop button (E) is pressed in. Emergency Stop An emergency stop button (E) has been pressed but the machine has not been reset. Preheating oil The oil is being heated. The machine will not run until the correct temperature has been reached. Oiltemp OK The oil has reached the correct temperature. Reset is not required. "Oil overheated" The temperature of the hydraulic oil is too high. The machine will not reset or start until the oil has cooled down and the message Has been overheated is displayed. Has been overheated The temperature of the hydraulic oil has been too hot but is now back down to an acceptable level, and the machine can be started without being reset. Low The oil level in the hydraulic tank is too low. Check for any oil leak. Repair the leak and refi ll with oil. The message Oil level is displayed. Reset by pressing the reset button (K). Oil level The oil level in the hydraulic tank has been too low or is close to the too-low level. Reset by pressing the Reset button (K). Motor protection The electrical motor s overload protection has been activated (the motor is overloaded). Wait for a few minutes so that the overload protection can reset itself. Reset by pressing the reset button (K). 7
8 0 OFF When cleaning, all power to the machine should be turned off and the main power switch (D) should be secured with a padlock. A notice informing people that servicing is in progress should be hung on the control panel. Always use protective gloves and appropriate tools when cleaning the space in and around the guillotine. Knife down The guillotine (Y) has not reached the lower sensor (Q). Press the reset button (K). Start the machine using the start button (L). Run the machine until the guillotine reaches its upper position. Stop the machine in this position using emergency stop (E). Turn the main power switch (D) off and disconnect the plug from the mains. Clear the press chamber (S) of material. Knife up The guillotine (Y) has not reached the upper sensor (T). Remove the cover plate (P) on the rear of the machine in order to access the guillotine (Y). Check that no material has accumulated on the guillotine. Check the function and position of the upper sensor. Feed plate The feed plate (I) has not reached the rear sensor (U). Remove the cover plate (V) on the feed plate. Check that no material has accumulated at the rear of the feed plate. Check the function and position of the rear sensor. Press The press cylinder has not reached its forward position. Press the reset button (K). Start the machine using the start button (L). Run the machine until the press cylinder reaches its rear position. Stop the machine in this position using emergency stop (E). Turn the main power switch (D) off and disconnect the machine s power cable. Secure the main power switch using a padlock. Clear the press chamber (S) of material. Also clean around the front (Z) and rear (Å) sensors. Fault on B317 Pressure sensor fault. Contact authorised service personnel. Important. Change PLC battery! - The battery in the PLC must be changed. Contact authorised service personnel immediately. Book service The machine requires servicing. Contact authorised service personnel. SETTING THE OPERATING TIME (on the terminal): Terminal text BRICKMAN - Press F4, twice READY TO START Main menu - Press the down arrow until the cursor is on Settings - Press Enter Settings - Scroll down until the cursor is on Operating time at start - Press Enter Operating time Time control - Move the cursor to YES (to set the number of minutes) - To change to NO (continuous operation), press Enter - Scroll the cursor to XX in Operating time xx minutes - Press and hold the NUM key and enter the desired operating time in minutes - Press Enter to confirm the selection - Press F4 several times until "BRICKMAN 300, READY TO START" is displayed. 8
9 DIAGRAM OF TERMINAL FUNCTIONS Svenska Use the arrow keys and confi rm with Enter MAIN MENU: OP. info Settings Manual mode Language Service Log in OPERATING INFO: Total running time Oil temperature Monitor view I/O Status TOTAL RUNNING TIME: hours OIL TEMPERATURE: 20 degrees Celsius MONITOR VIEW: READY TO START I/O STATUS Inputs: X0 OFF X1 ON etc. Outputs: Y0 ON Y1 OFF etc. Blocks in this colour are only accessible after logging in using the password. Original password: "0000" Blocks in this colour are only accessible to authorised service personnel. SETTINGS: OP time Auto start Air fan 50/60Hz Press loop Default reset OPERATING TIME: Time control (YES) OP. time 2 minutes NOTE! Password required: AUTO START: Auto start (Off) FC/UL time 10 s AIR FAN: Start temp. 50 degrees C 50/60Hz: Select frequency 50 Hz Press loop: 110 bar Reset to default (F1) WARNING! 9
10 WEEKLY INSPECTION AND MAINTENANCE NOTE! Always padlock the main power switch (D) during inspection and maintenance, service work and the removal of trapped waste, etc. 0 OFF Clean the machine and the area around it. Ensure that there are no foreign objects on the machine. Ensure that there are no signs of damage on the machine. Remove the cap (N). Vacuum the hydraulic assembly. Make sure that there are no oil leaks. If a fan is fi tted: Before lifting off the cap, disconnect the connector in the electrical box (C) that connects the fan in the cap above the hydraulic assembly. Remove the cover plate (O) and clean out any material that may have got onto the wrong side of the feed plate (I). Remove the cover plate (P) and clean out any material that may have got onto the guillotine (Y). Check that the machine has no oil leaks and that all bolts and nuts are tightened. Check that no parts are loose or damaged. SAFETY CHECKS Regularly check that the cover plates are intact and in place. Also, be sure to regularly check the function of the two emergency stops (E). Contact authorised service personnel immediately if the emergency stops do not work. If any fault is found in the functions listed above, the machine must not be used until it has been repaired by authorised service personnel. Service and repairs must only be carried out by qualifi ed and competent personnel, and in accordance with the machine manufacturer s instructions. SERVICE The fi rst service should be carried out within 500 hours of operation. Subsequent service should be carried out at hour intervals or once a year. These intervals may vary depending on the surrounding environment and the material to be compacted by the machine, and should therefore be discussed with the manufacturer s authorised service personnel. Oil change: Contact the local authorities for advice regarding how to reduce environmental impact when dealing with residual oil. 10
11 EC DECLARATION OF CONFORMITY We AB ORWAK Box 58 SE Sävsjö, Sweden Tel: Fax: declares under its sole responsibility that the product model:... Brickman 900 with serial number:... to which this declaration relates is in EC conformity with the following Standards or other normative documents following the provisions of Directive 2006/42/EEC (Machinery Directive) 2004/108/EEC (EMC Directive) 73/23/EEC, 93/68/EEC, 2006/96/EC (Low Voltage Directive) SS-EN SS-EN ISO13850 SS-EN ISO SS-EN ISO SS-EN ISO13857 SS-EN 982 EN Ljungby Product Manager and compiler of technical documentation 11
12 Leader in compaction and baling solutions Orwak is a world leader in compaction and baling solutions for solid waste material at source. We develop, manufacture and market a comprehensive range of waste compactors, baling systems and Brickman briquette presses for recyclable materials that make waste management more profi table. We also o er fully automatic balers for recyclable materials through our subsidiary Presona. This is where Orwak s unequalled technology, expertise and service support make all the di erence. When you partner with Orwak, you also gain access to the vast experience we have built up over the last 35 years. Orwak is wholly owned by the Norwegian company Tomra, a leading global player in providing integrated solutions for recovering and recycling used packaging.
Edition 6, From serial no Publ. no Orwak 5030-CE. Operating manual
Edition 6, From serial no. 78087 Publ. no 4869700-00 2008-01 Orwak 5030-CE Operating manual English CONTENTS Safety...8 2 Operating instructions...9 3 Technical specifications...10 4 Dimensional sketch...10
More informationEdition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)
Edition 8 From serial no. 106000- Publ. no 4869701-00 OM 5030NHD; 2012-02 Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL) English CONTENTS Safety...8 2 Operating instructions...9 3 Technical specifications...10
More informationEdition 5, From serial no Publ. no OM3300, Orwak 3300 OPERATING INSTRUCTIONS (IN THE ORIGINAL)
Edition 5, From serial no. 106000- Publ. no 4869014-00 OM3300, 2012-02 Orwak 3300 OPERATING INSTRUCTIONS (IN THE ORIGINAL) English CONTENTS Safety...82 Waste matri...82 Operating instructions...93 Technical
More informationEdition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)
Edition 8, From serial no. 106000- Publ. no 4869699-00 OM 5030, 2012-02 Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL) English CONTENTS Safety...8 2 Operating instructions...9 3 Technical specifications...10
More informationOPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4
GB OPERATING MANUAL ORWAK 3400 March 2005 PUBL. NO 4869057-00 Edition 4 English TABLE OF CONTENTS Safety... 82 Operating instructions... 93 Technical specifications. 104 Dimensional drawing... 104 Transport...
More informationEdition 2, From serial no Publ. no OM 3115, Or wak 3115 OPERATING INSTRUCTIONS (IN THE ORIGINAL)
Edition 2, From serial no. 106000- Publ. no 4870132-00 OM 3115, 2012-02 Or wak 3115 OPERATING INSTRUCTIONS (IN THE ORIGINAL) CONTENTS Safety... 2 Control panel... 3 Operating instructions... 4 Installation...
More informationInstructions for the fan motor control system with integrated wiring terminals SILVER C
Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.
More informationOperating instructions SENTRI4 Control panel based Fire detection and alarm system
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 30 32 Zones Healthy 15:45 Fault Power Fault System Fault SenTRI 4 Fire System Designed to EN54 Pt 2 & 4 Operating instructions
More informationInstructions for the fan motor control system, SILVER C
Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is
More informationKITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE
KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE 2 GLEC-6 - Installation and maintenance CONTENTS 1 Important information... 3 2 Safety notes... 3 3 Technical description...4 4 Transport... 6 5
More information1592 In Cab Monitor (ICM) QUICK START GUIDE
1592 In Cab Monitor (ICM) QUICK START GUIDE Refer to your Operators Manual for additional information on controls 89-023 Rev - C 4/2013 Program # 1592.0.45.3 SAFETY Allied Systems Co. is concerned with
More informationHOT 2000 USER MANUAL. Version 3.1. This manual shall be read in its entirety before using the machine.
HOT 000 USER MANUAL Version 3. This manual shall be read in its entirety before using the machine. IMPORTANT SAFETY INSTRUCTIONS When using Hot 000, basic precautions should always be taken, including
More informationOperating instructions Vigilon panel and Network node Fire detection and alarm system
Healthy 15:45 Fault Power Fault Vigilon Fire System GENT 2015 Designed to EN54 Pt 2 & 4 System Fault Operating instructions Vigilon panel and Network node Fire detection and alarm system Test Fire Fault/Dis
More information6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL
6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0)
More informationTopvex SR03, SR04, SR06 Compact Air Handling Unit
Compact Air Handling Unit GB GB Corrigo ver. no. 1.2-1-00 Manufacturer Our products are manufactured in compliance with applicable international standards and regulations. Systemair AB Industrivägen 3
More informationElectronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions
Electronically controlled instantaneous water heater CEX 9-U: 27910-50 C models Installation instructions For 50 ºC models, the appliance delivers water not exceeding 50 ºC in accordance with AS3498. 1.
More informationMW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance
MW001 Integrated Dishwasher Manual for Installation, Use and Maintenance Important The CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation of this product.
More informationJLBIHD624 60cm Cooker Hood
JLBIHD624 60cm Cooker Hood User guide 2 Cooker hood user guide Contents Contents 3 Introduction 4 Safety is important 4 In the box 4 Safety information 5 Important safety information 5 Warnings 5 Cautions
More informationDRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL
DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. CONTROL PANEL... 9 5.1
More informationHOT 4000 USER MANUAL. Version 2.1. This manual shall be read in its entirety before using the machine.
HOT 4000 USER MANUAL Version. This manual shall be read in its entirety before using the machine. IMPORTANT SAFETY INSTRUCTIONS When using Hot 4000, basic precautions should always be taken, including
More informationWhole Room Dryer WRD, WRD/110
Whole Room Dryer WRD, WRD/110 User Instructions Whole Room Dryers CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-8117-0000 Iss.1 12/06 Fig 1 Fig 2 Fig 3 Fig 4 CONTENTS Page 1 Product information...................4
More informationAUTOMATIC SOLUTION FOR CONTINUOUS OUTPUT OF MILL-SIZE BALES
ORWAK HORIZONTAL AUTOMATIC SOLUTION FOR CONTINUOUS OUTPUT OF MILL-SIZE BALES CENTRALIZED WASTE HANDLING Fully automated horizontal balers meet the challenges presented by centralized waste handling in
More informationPVL1300 INSTRUCTIONS FOR USE
PVL1300 INSTRUCTIONS FOR USE GB Elpress AB P.O. Box 186 SE-872 24 KRAMFORS, Sweden Tel: +46 612 71 71 00 Fax: +46 612 71 71 51 E-mail: sales@elpress.se www.elpress.net 2 Table of contents Symbols... 4
More informationST1. Mod. USE AND MAINTENANCE MANUAL
Mod. USE AND MAINTENANCE MANUAL 2 Use and Maintenance Manual ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
More informationInstructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes
Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors
More informationNHS VERTICAL AGITATOR
INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS NHS VERTICAL AGITATOR INOXPA, S.A. c/telers, 54 Aptdo. 174 E-17820 Banyoles Girona (Spain) Tel. : (34) 972-57 52 00 Fax. : (34) 972-57 55 02 Email: inoxpa@inoxpa.com
More informationQuality makes the Difference. AquaTREND uni. User s Manual Humidifi er for Therapeutic Air Flow
Quality makes the Difference AquaTREND uni User s Manual Humidifi er for Therapeutic Air Flow SERIAL NUMBER HOFFRICHTER GmbH delivers all its systems with a serial number in order to ensure traceability.
More informationFire detection and alarm system Operating instructions
Fire detection and alarm system Operating instructions Operating instructions Table of Contents User responsibility - - - - - - - - - - - - 4 Daily - - - - - - - - - - - - - - - - - - - 4 Weekly - - -
More informationElectronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions
Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Installation instructions These appliances deliver water not exceeding 50 ºC in accordance with AS3498. 1. Overview
More informationAlways keep this manual in a safe readily accessible location. MODEL SERIAL SERVICE COMPANY TELEPHONE NUMBER
Always keep this manual in a safe readily accessible location. MODEL SERIAL SERVICE COMPANY TELEPHONE NUMBER For Operating Instructions or Technical Support Call 1-507-886-6666 Last Revision: 1/31/12 Starting
More informationINFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS
INSTRUCTIONS FOR: INFRARED IP55 HEATER MODEL:- QZWP45N Thank you for purchasing a Consort Claudgen product. Manufactured to a high standard this product will, if used according to these instructions and
More informationUser s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE
User s Manual Variable Speed Ultra-High SEER Split System These units have been designed and tested for capacity and effi ciency in accordance with ARI standards. These outdoor air conditioning units are
More informationDrying Cabinet Installation and Operating Manual
Drying Cabinet Installation and Operating Manual Model:- ECO Dryer 2.0 HP Heat Pump Technology CONTENTS THIS USER MANUAL 3 DATA PLATE DETAILS 3 ADVICE ON SAFE OPERATION 3 DESCRIPTION OF THE CABINET 4 AIR
More informationUSER GUIDE VOGUE COMBI GEN2 C26 C32 C40
USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not
More informationOperating instructions
Operating instructions For the operator Operating instructions ecotec plus Gas-fired wall-hung high-efficiency boiler GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Telefon
More informationUSER GUIDE VOGUE MAX SYSTEM
USER GUIDE VOGUE MAX SYSTEM 15 18 26 32 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not
More informationAPC BC300 Series 40kW 208/450/480V User Guide
APC BC300 Series 40kW 208/450/480V User Guide Copyright 2002 APC Denmark ApS This manual is subject to change without notice and does not represent a commitment on the part of the vendor Thank You Thank
More informationVETO CLEANER 500 FLUE GAS CLEANER
As of serial number 3100 0001 VETO CLEANER 500 FLUE GAS CLEANER USER MANUAL SPARE PARTS LIST Manufacturer: ALA TALKKARI Veljekset Ala-Talkkari Oy FI-62130 HELLANMAA TEL. +358 6 433 6333 FAX +358 6 437
More informationCAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE
User instructions Model X46 Escalator and Travelator cleaner CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-7845-0000 Iss.1 07/04 Fig 1 Fig 2 2 Contents Page 1 Product information... 4 1.1
More informationMore profitable waste handling. with brickman
More profitable waste handling with brickman Meeting the challenge with brickman more than 1000 installations worldwide Fully automated Brickman briquette presses meet the challenges presented by waste
More informationUser Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)
User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual
More informationInstallation manual Washer extractor
Installation manual Washer extractor W555H Type W.55.H Original instructions 438 9054-30/EN 2017.11.06 Contents Contents 1 Safety Precautions...5 1.1 General safety information...6 1.2 Commercial use
More informationUV - Monitor UVT 16. Use. Description
UV - Monitor UVT 16 Use The UVT 16 Monitor is used to monitor signals from UV probes or sensors applied to sources of radiation, providing a control system for small items of UV equipment. Description
More informationUser & Installation instruction
LADDOMAT MR 40 User & Installation instruction Scope of delivery Valve package Laddomat 41-100 with: Charge and discharge valve with 2 non-return valves and thermal three-way valve. 2 pumps, LM6A-130.
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL
CENTRAL FANS COLASIT LTD Unit 12A, Palmers Road, East Moons Moat, Redditch. Worcs. B98 0RF Tel: 01527-517200 Fax: 01527-517195 Edition 04_13 INSTALLATION, OPERATION & MAINTENANCE MANUAL CIV Fan Range Valid
More informationSwaging Machine Type H50-46ECO
ENDEAVOUR Int. Ltd. Tel +44 (0) 1225 446770 Fax +44 (0) 1225 446775 USER MANUAL Swaging Machine Type H50-46ECO Website: www.hydralok.net CONTENTS WARRANTY CONDITIONS... 3 EC DECLARATION OF CONFORMITY...
More informationUser Manual. Dryer Controller M720
User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009
More informationDryer Controller M720
User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,
More informationHULME MARTIN HEAT SEALERS
HM1000P Operating Instructions HULME MARTIN HEAT SEALERS HULME MARTIN HEAT SEALERS www.hulmemartin.co.uk SAFETY INSTRUCTIONS HEAT SEALING EQUIPMENT A. Protection against hazards arising from the electrical
More informationTornado Operations & Maintenance Manual
TORNADO INDUSTRIES 7401 W. LAWRENCE AVENUE CHICAGO, IL 60706 (708) 867-5100 FAX (708) 867-6968 www.tornadovac.com Tornado Operations & Maintenance Manual MODEL NO. 99690 BD 22/14, 99720 BD 26/14 L9722
More information_en SP 5080 OPERATING MANUAL CHANNEL BALING PRESS SP Keep this instruction for future use!
2.990.999.120_en SP 5080 OPERATING MANUAL CHANNEL BALING PRESS SP 5080 Keep this instruction for future use! HSM GmbH + Co.KG, Austrasse 1-9, 88699 Frickingen / Germany Tel. + 49 75 54 2100-0 Fax + 49
More informationFF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance
FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance 1 Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949
More informationInstallation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke
918149-0 GB Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke 1. Application 2. Handling 2.1 Marking 2.2 Weight 2.3 Transport 3. Storage 4. Installation 4.1 Prior to attachment 4.2 Attachment
More informationTECHNICAL NOTICE GH/GHO/GAE V
TECHNICAL NOTICE GH/GHO/GAE V1.0-02.14 INDUSTRIAL COOLING UNITS Identification Marksa SA Industrial cooling 39, avenue du Technicum CH-2400 Le Locle Version Date Modifications 1.0 14.02.14 First edition
More informationSHORT WAVE INFRARED PANEL DRYER
INSTRUCTIONS FOR: SHORT WAVE INFRARED PANEL DRYER MODEL: IR3000 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
More informationFire control panels FC360
Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses
More informationwc431 Slimline Integrated Dishwasher Manual for Installation, Use and Maintenance
wc431 Slimline Integrated Dishwasher Manual for Installation, Use and Maintenance Contents Contents... 2 Important... 3 Important Notes... 4 Recommendations... 5 Before First Use... 5 Control Panel...
More informationCommercial Fan Heater
Commercial Fan Heater Installation and Operating Manual Catalogue Numbers: CH06CSiRX, CH06CPiRX, CH09iRX, CH12iRX, CH15iRX. INDEX Section General Information -----------------------------------------------------------
More informationINSTRUCTIONS. Family 4 N 4062 Issue C Date 01/2011. CMV Certification reference NF205.
INSTRUCTIONS 412 137 Family 4 N 4062 Issue C Date 01/2011 www.marque-nf.com CMV Certification reference NF205 CONTENTS 1. INTRODUCTION... 3 2. PRESENTATION OF YOUR DUOLIX MAX DOUBLE FLOW UNIT... 3 2.1.
More informationMODELS HSCFH60WX, HSCFH90WX, HSCFH120WX
Commercial Inst allation Fan Heater and Operating Manual MODELS HSCFH60WX, HSCFH90WX, HSCFH120WX INDEX Section General Information ----------------------------------------------------------- 1 Installation
More informationSnifter ATEX22 VERSION. User Manual. Distributor
Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5
More informationWSK300 Multifunction Wall Control
WSK300 Multifunction Installation & Operating Instructions WARNING Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions: Installation and
More informationModel 3.6m. User Manual Original instructions
Model 3.6m User Manual Original instructions CONTENTS Introduction 3 Description 4 General Do s and Don ts 5 Controls and operation 7 Smoke alarms 9 Emergency procedures 11 Fault finding 19 Changing smoke
More informationIntelligent Security & Fire Ltd
full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04
More informationINSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO
INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO .Technical specifications Boiler power DESCRIPTION Water content in a boiler Required draft Supply
More informationOPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19
OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER Version DC19 1. Application. Controller RK-2006LPP is designed for temperature control of solid fuel fired water boilers
More informationIllustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285
Operating manual BlueMobil 60 Item no: Z-3285 Original operating manual Illustration shows item no Z-3285 Important Copyright It is essential that you read this manual thoroughly before the initial operation
More informationUser s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas
User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5
More informationOPERATING INSTRUCTIONS. Drying cabinet DC 7774 DC Read the instructions before using the machine.
OPERATING INSTRUCTIONS Drying cabinet DC 7774 DC 7784 Read the instructions before using the machine. Dear ASKO customer, Congratulations on making an excellent choice, and welcome to the ASKO family,
More informationWaste Dewaterers. Kitchen hygiene with style and functionality
Waste Dewaterers Kitchen hygiene with style and functionality Page 1 How IMC Food Waste Dewaterers Work IMC dewaterers are ideal for kitchens where food waste cannot be disposed of via mains drainage,
More informationCompact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list
OPERATOR'S MANUAL Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614
More informationTTV 4500 / TTV 4500 HP / TTV 7000
TTV 4500 / TTV 4500 HP / TTV 7000 EN OPERATING MANUAL AXIAL FAN TRT-BA-TTV4500-4500HP-7000-TC-003-EN Table of contents The current version of the operating manual can be found at: Notes regarding the operating
More informationTHERMOMATIC EC HOME. Installation and User Guide, version 1.0
THERMOMATIC EC HOME Installation and User Guide, version 1.0 Table of contents: 1. Overview, dimensions, choice of control functions, extras, pages 2-3 2. Delivery scope, page 4 3. Start Guide, pages 5-7
More informationKitchen Appliance Lift INSTRUCTION MANUAL
Kitchen Appliance Lift INSTRUCTION MANUAL Contents Section: Headline: Page: 1. Introduction...4 2. Declaration of Conformity...4 3. Intended use - Technical data...4 Installation instructions: 4.1 Mechanical
More informationOPERATING MANUAL. for the modular heat presses. Secabo TC5 SMART and TC7 SMART
OPERATING MANUAL for the modular heat presses Secabo TC5 SMART and TC7 SMART Congratulations on the purchase of your Secabo heat press! Please read this operating manual carefully to ensure a smooth production
More informationJLBIHD920 90cm Chimney Hood
JLBIHD920 90cm Chimney Hood User guide 2 Cooker hood user guide Contents Contents 3 Introduction 4 Safety is important 4 In the box 4 Safety information 5 Important safety information 5 Warnings 5 Cautions
More informationDOL 31 Speed Controller Technical User Guide
Technical User Guide For other language variants of this document we refer to your local dealer or http://docs.skov.com/1158. Available from April 2016. 612061 2016.09.20 Technical User Guide Program
More informationSOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59
SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery
More informationControl Panel User Guide
Fire Detection & Alarm System Control Panel V4.14 Control Panel User Guide (TO BE RETAINED BY USER) 26-0397 Issue 6 Fike s policy is one of continual improvement and the right to change a specification
More informationOperating instructions
The energy you need Operating instructions Betacom 3 24c -A (H-GB) 30c -A (H-GB) GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information...
More informationINSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented
INSTALLATION MANUAL RD SERIES Digital Electric Water Heater Wall-hung Unvented WELCOME Dear Customer, Thank you for choosing the RD Series electric water heater, with an exclusive electronic temperature
More informationInstruction manual CCU 5-P. Table of contents
Instruction manual Version: 1.0040.40 Updated: 09/02/2018 Replaces: CCU 5-P Table of contents Introduction... s. 2 Design / Construction... s. 3 Flammable gases and liquids... s. 4 Safety... s. 4 Service
More informationMC 31 Speed Controller Technical User Guide Code no GB
Technical User Guide Code no. 99-97-0968 GB Ausgabe: 0 /201 Technical User Guide Program Version The product described in this manual holds software. This manual corresponds to: Software version 1.3 It
More informationREAD AND SAVE THESE INSTRUCTIONS
XXXXXXX-0 EN 1904 READ AND SAVE THESE INSTRUCTIONS BASIC-PLC CONTROLLER MANUAL For all Condair desiccant dryer with equipped with Basic- PLC valid from version: PLC-35/PLC-45 18.04.03 Dehumidification
More informationSIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions
Original instructions SIRe Competent Air Curtains Water With quick guide SIReAC SE... 2 GB... 19 DE... 36 FR... 54 For wiring diagram, please see p.71-73 For more languages, please see www.frico.se SIRe
More informationSpa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)
Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) P.N. 7876C (export) February 12, 2015 For Spas equipped with BP2100, BP6013 controllers and Spa Touch panel. Spa
More informationSwedish design and manufacture since 1967
Swedish design and manufacture since 167 PVP MA20-14 rev.2 Manual User manual Copyright 2017 Pahlén AB, Box 728, SE-14 27 Upplands Väsby, Sweden Tel. +46 8 54 110 50, Fax +46 8 50 868 80, e-mail: info@pahlen.se,
More informationMemcom Emergency Telephone
Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming
More informationTECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:
TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: 560955 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) 1 CONTENTS Page 1) INTRODUCTION 1.1) Description 3 1.2) Dimensions & connections
More informationTornado Operations & Maintenance Manual
Tornado Industries, LLC 333 Charles Court West Chicago, IL 60185 www.tornadovac.com Tornado Operations & Maintenance Manual MODEL NO. 99414 Form No. L9740AB Tornado Industries, LLC. All rights reserved
More informationUSER S MANUAL NKP. Duct heater for supply air pre-heating with external control
USER S MANUAL Duct heater for supply air pre-heating with external control CONTENTS Contents... 2 Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Design
More informationQUICK USER GUIDE. Alarm Control Panel
Alarm Control Panel Firmware version 2.10 QUICK USER GUIDE The full version of User Manual and other manuals are available on CD included in the control panel delivery set or on the website www.satel.eu
More informationACN SMOKE INSTALLATION AND MAINTENANCE
NovAx ACN SMOKE INSTALLATION AND MAINTENANCE 918149-0 English 918149-0 GB Installation and maintenance NovAx smoke exhaust fan type ACN smoke 1. Application 2. Handling 2.1 Marking 2.2 Weight 2.3 Transport
More informationGLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans
Air Comfort Air movement Duct & Box Fans GLEB KITCHEN exhaust FAN >> Installation and Maintenance Kitchen Exhaust Fan GLEB Installation and Maintenance Important Information, Safety notes, Technical Description
More informationLogic+ Combi
USER GUIDE Logic+ Combi 24 30 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use
More informationUSER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -
USER GUIDE DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER - II CONTENTS 1. SYMBOLS AND WARNINGS... 5 2. GENERAL INFORMATION... 6 3. WARNINGS... 7 4. GENERAL DESCRIPTION... 8 5. INSTALLATION...
More informationMW401 Integrated Dishwasher
MW401 Integrated Dishwasher Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu
More informationTTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN
TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating
More informationUSERS GUIDE. LOGIC+ Combi 24, 30, 35
USERS GUIDE LOGIC+ Combi 24, 30, 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use
More informationFWC152 / FWC302 / FWC602 / FWC622 Wine Coolers
FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949
More information