VASKA B11. gas -fireplace installation guide
|
|
- Homer McBride
- 5 years ago
- Views:
Transcription
1 VASKA B11 gas -fireplace installation guide Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0) F. +31(0)
2 DESCRIPTION OF THE FIREPLACE CONTENTS FOREWORD 2 2. INTRODUCTION 3 3. SAFETY INTRUCTIONS 4 4. INSTALLATION INSTRUCTIONS Gas connection Placing of the appliance Opening the door Placing of the wood set 7 5. CONVERTING THE FLUE 8 1. Door 2. Window 3. Handle 4. Wood blocks 5. Inspection screen 5 6. Control block 7. Bottom plate 8. Burner 9. Pilot burner 10. Support 6. CLEANING AND MAINTENANCE Cleaning the glass Care of the coated parts and ceramics Care of the soapstone Burner and control block Gas control 11 TECHNICAL DATA ø100/ø FAULTS DISPOSAL OF THE PACKAGING AND THE APPLIANCE INDEX 1 LIST OF SPARE PARTS 463 ø
3 1. FOREWORD 2. INTRODUCTION This appliance is supplied with instructions for use and installation. The instructions for use are intended for the consumer and besides information about the use of your appliance, the booklet also includes advice on safety and maintenance. In compiling the installation instructions, it has been assumed that the appliance will be installed by a qualified gas-fitter who is familiar with both national and local regulations Please keep this book safely for future use. In addition to information about setting-up the appliance, its operation and maintenance, these instructions for use also contain advice about its safe use. The appliance is fully protected by means of a modulating thermostatic switch and a thermoelectric pilot flame safety device to prevent the accidental escape of gas from the main burner. The appliance is protected by a thermal safety device (TSD). This safety device switches the appliance off if flue gases spread through the room. This can happen if there is insufficient ventilation and/or if the flue does not work properly. The appliance is available with a steel mantle or soapstone or ceramic covering. Should it prove necessary, due to moving house for instance, the flue outlet can be moved from the top to the rear of the fireplace or vice versa. A conversion kit is available from Faber International for this purpose. 2 3
4 Safety and general information. 3. SAFETY INSTRUCTIONS Before installation, ensure that the local distribution conditions (identification of the type gas and pressure) and the adjustment of the appliance are compatible. This gas appliance is factory set and shall not be adjusted by the installer. General safety Note: Since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Because of the natural circulation of air, moist and volatile components from paint, building materials, carpet etc. will be attracted. These components can settle themselves down onto cold surfaces in the form of soot. As on all heat producing appliances, soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured. This should be born in mind when installing the appliance. It is the law in the UK that all gas appliances, are installed by a competent person in accordance with the Gas Safety (Installation and Use) Regulations (As amended), the relevant British Standards for Installation work, Building Regulations, Codes of Practice and the manufacturers instructions. The installation should also be carried out in accordance with the following where relevant; The installation should also be carried out in accordance with the following where relevant; BS8303 BS5440 Parts 1&2 BS6891 BS5871 Part1 BS715 BS1251 Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development Department. In the Republic of Ireland installation should be carried out in accordance with IS813, ICP3, IS327, Building Regulations, Codes of Practice, the manufacturers instructions and any other rules in force. 4 Failure to comply with the above could leave the installer liable to prosecution and invalidate the appliance warranty 5
5 4. INSTRUCTIONS FOR INSTALLATION 4.3 OPENING THE DOOR 4.1 GAS CONNECTION A G3/8" gas connection should be made with a (CE approved) G1/2" stopcock in the supply pipe, in the chimney. Be sure that the controls do not get twisted during connection. Avoid tension on the controls and the gas line. Once the gas is connected, check all fittings for leaks. 4.2 PLACING OF THE APPLIANCE Place the base of the fireplace at least 5 cm from the chimney breast. Connect the appliance to the gas supply.the appliance is fitted with a pressure regulator. Check all the gas connections for leaks. Use soapy water and/or a gas-leak detector. Connect the fireplace to the chimney pipe. A 100 mm ø pipe should be connected to the rear flue outlet. A 150 mm ø pipe or a 100 mm ø pipe with a 150 mm ø decorative pipe should be connected to the top flue outlet. Corrosion-resistant material should be used to make the joint between the outlet and the chimney pipe. This connection pipe should never be attached lower than the flue outlet itself. In the event the flue outlet is connected to the chimney pipe by means of an elongated pipe, this should be attached at an upward gradient of at least 2% as viewed from the flue outlet. To avoid condensation forming in a brick chimney and improve the draught, if necessary the chimney should be fitted with an aluminium or stainless steel pipe with a minimum diameter of 100 mm. Attach the thermostat sensor to the skirting using the clip provided. 4.4 LOG SET Fig. 1 opening the door The fireplace door can be opened by first loosening the screw in the door handle, on the left-hand side of the window, then lifting the handle itself (see fig. 1). Note! To ensure proper burning, the log set may only be arranged according to the instructions provided by Faber International (see fig. 2). Other placement can cause soot. Fig. 2 log set Before arranging the log set, scatter the bag of embers over the burner. Place the longest log on the far right of the firebox, with its end resting on the support in the middle. Place the shorter log on the left, with its end resting against that of the first log, in the middle of the burner zone. Place the final log diagonally over the first two, with one end at the foot of the right-hand log and the other around the middle of the left-hand one. 6 Close the door after arranging the log set. 7
6 5. CONVERTING THE FLUE The fireplace is supplied as standard with the flue outlet on the top. The outlet can be converted from the top to the rear as follows. However, you will require a blank top plate, which can be ordered from Faber, to do so. Should you wish to convert a fireplace with a rear outlet to a top outlet, simply carry out the following instructions in reverse order. 6. CLEANING AND MAINTENANCE The appliance must be cleaned and checked annually by an authorized installer. This applies for the Direct-vent system as wel. Check that: - the gas supply, combustion chamber and flue gas vent systems are all airtight; - the regulator and the thermocouple circuit function properly and that the burner ignites properly Clean (if necessary): - the pilot system; - the burner; - the combustion chamber; - the flue gas exhaust.r. - Release the square cover plate (1) from the rear of the fireplace by loosening the screws. - Detach the rear panel (2) from the fireplace. 1 - Remove the round blank (3) from the flue aperture - Screw the 100 mm flue outlet (1) to the rear flue aperture. - Refit the rear panel (3) to the fireplace. - Screw the round blank to the top flue aperture. - Fit a blank top plate (2) to the fireplace. This can be ordered from Faber. - Connect the rear flue outlet to the chimney pipe. 2 3 Fig. 3 removing the cover plates Fig. 4 fitting the flue outlet 6.1 CLEANING THE GLASS Depending on the intensity of use, a layer may in time form on the glass. This layer can be removed with a special glass cleaner or ceramic cook-top cleaner. Follow the instructions on the package. We advise you to have the appliance cleaned by an authorised installer. An improperly working flue and logs in the wrong positions will cause the glass to become dirtie 6.2 CARE OF THE COATED PARTS AND CERAMICS Polish the coated finish with a soft duster. Remove any stains using a damp cloth or lukewarm water once the fireplace has cooled down. Never use scouring agents, petrol, paraffin or other solvents to clean the fireplace. 6.3 CARE OF THE SOAPSTONE Use soap and water to remove any dirt or grease from the soapstone (remove the stones from the fireplace first). Minor scratches can be removed using fine sandpaper (240 grey waterproof). 8 9
7 6.4 BURNER AND CONTROL BLOCK 6.5 GAS CONTROL 1 2 A Adjusting screw pilot burner B Reduced injector C Gas pressure for burner pressure D Gas pressure for pre pressure E Pressure adjuster burner pressure A V1 B V2 fig. 5 frontal view 1. Flame supervision system 2. Burner 3. TSD sensor 4. Pilot flame injector 5. Burner injector 6. Thermal safety device (TSD) 7. Spark ignition 8. Thermocouple V1: V2: E C D fig. 6 gas control block 10 11
8 7. FAULTS 8. DISPOSAL OF THE PACKAGING AND PROBLEM Appliance will not light or goes out. CAUSE - Air in the supply pipe (after appliance has not been in use). - Insufficient gas pressure. - The pilot flame is dirty. - The thermocouple contact does not engage properly. SOLUTION - Venting. - Check that the gas tap is open and check the gas line to see if it is dirty. - Clean the burner carefully with a vacuum cleaner. - Check the thermocouple circuit. THE APPLIANCE The appliance packaging is recyclable. The packaging could include the following materials: - cardboard; - CFC-free foam (soft); - wood; - plastic; - paper. These materials should be disposed responsibly and in conformity with government regulations. Information on how to responsibly dispose of discarded appliances can be obtained from the local authorities. - The Thermal Safety Device (TSD) is switched on. - The TSD switches on if combustion gases flow into the room because they cannot escape through the flue. Make sure that the flue operates correctly and provide good ventilation. If the TSD comes into operation frequently, you should contact the installer. Poor flame distribution. - The logs are not positioned properly. - Arrange the log set properly The burner is quite dirty because of ash from combustible materials has gotten into the burner. - Clean the burner carefully with a vacuum cleaner. Be careful not to damage the burner with the sharp edges of the vacuum cleaner. 13
9 APPENDIX 1 LIST OF SPARE PARTS Glasset Vaska Side-wall lining steel T Side-wall lining soap stone T Upper plate with hole T Upper plate without hole T Upper plate with hole soap stone T Upper plate without hole soap stone T Handle gilded U Handle chrom U Handle black U Set SIT 630 with pressure Set TRS Injector Set Pilot flame 145 natural gas Log set Embers Sprayer Lacquer
VASKA C11. gas-fireplace user manual. Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0) F.
VASKA C11 gas-fireplace user manual Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501 40 010 458 01.51 DESCRIPTION OF THE FIREPLACE CONTENTS 1 2
More informationVASKA C11. gas -fireplace installation guide
VASKA C11 gas -fireplace installation guide Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501 40 010 459 01 51 DESCRIPTION OF THE FIREPLACE CONTENTS
More informationTorch framed Installation Guide
Torch framed 40010567-0602 Installation Guide 1 2 3 4 1 < < < < 5 6 7 > > > > 2 Content 1 Introduction... 1 2 Safety Instructions... 2 3 Installation requirements... 3 3.1 Rear surface construction...
More informationHestia Installation Guide
Hestia 40010610-0746 UK Installation Guide Content 1.1 1.2 1.3 1.4 A B C D 1.5 1.6 1 < < < < Hestia with Wirdum Surround 2.1 2.2 2.3 2.4 2.5 2.6 > > > > 2 Hestia with Jellum Surround 3.1 3.2 3.3 3.4 3.5
More informationVaska Logburner. voorbeeld Installation guide
Vaska ogburner voorbeeld 40010627-2103 ENG Installation guide ENG 1.1 1.2 1.3 1.4 1.5 1 < < < < 1 Introduction The appliance can only be installed by a competent person in accordance with the Gas Safety.
More informationFyn Installation guide
Fyn 450 400100929-1114 ENG Installation guide ENG 1.1 1.2 A B 1.3 1.4 1 < < < < 2.1 2.2 2.3 3.1 3.2 2 < < < < 4.1 4.2 4.3 4.4 3 < < < < Table of contents 1 Introduction... 6 2 Safety instructions... 6
More informationMODEL 466 Radiant / Convector Gas Fire Black Beauty
O W N E R G U I D E MODEL 466 Radiant / Convector Gas Fire Black Beauty This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using your gas fire and keep
More informationFyn Installation guide
Fyn 600 4001131-1123 ENG Installation guide ENG 1.1 1.2 A B 1.3 1.4 1 < < < < 2.1 2.2 2.3 2.4 3.1 3.2 2 < < < < 4.1 4.2 4.3 4.4 3 < < < < 1 Introduction The appliance can only be installed by a competent
More informationClear Installation guide
Clear 40010631-0938 ENG Installation guide ENG 1.1 1.2 1.3 A 1.4 1.5 1 < < < < A B 2.1 2.2 2.3 C 2.4 2.5 2 < < < < 3.1 3.2 3-3 3 < < < < Inhoudsopgave 1 Introduction... 6 2 Safety instructions... 6 3 Installation
More informationSolution Installation guide
Solution 40011444-1327 ENG Installation guide ENG 1-1 1-2 1-3 1.4 1 < < < < 2.1 2-3 2-4 2 < < < < 3-1 3.2 3-3 3.5 3.6 3 < < < < 4-1 A 4-2 4-3 4 < < < < Dimensions Terminal position Distance (For good working
More informationOWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE
600B637/02 ETERNITY MODEL 540C (GC No. 32-032-19) INSET BALANCED FLUE GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM (GB) AND THE REPUBLIC OF
More informationRespect OC Installation manual
Respect OC 40011335-1235 ENG Installation manual ENG 1.1 1.2 A 1.3 1.4 A A 2.1 2.2 2.3 1 < < < < 2.4 2.5 B C A B A 2.6 2 < < < < 3.1 3.2 3.3 3.4 3.5 3.6 3 < < < < A B 3.7 4 < < < < L A A 4.1 A A 4.2 A
More informationDuet XL /0929. Installation guide
Duet XL 40010749/0929 ENG Installation guide ENG 1.1 1.2 1.3 1.4 1.5 A 1.6 1.7 1 < < < < B A 2.1 2.2 2.3 2.4 2 < < < < 2.5 2.6 2.7 2.8 3 < < < < 3.1 F F 3.2 3.3 4 < < < < Table of contents 1 Introduction...
More informationOWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )
5112499/01 OWNER GUIDE Model 750 INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia (GC No. 32-032-58) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION
More informationModel 341 Black Beauty Slimline
600B690/13 OWNER GUIDE Model 341 Black Beauty Slimline LIVE FUEL EFFECT GAS FIRE (GC No. 32-032-30) We trust that this guide gives sufficient details to enable this appliance to be operated and maintained
More informationULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE
ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE THE NATURAL GAS MODEL IS FOR G20 AT A SUPPLY PRESSURE OF 20mbar THE PROPANE GAS MODEL IS FOR G31 AT A SUPPLY PRESSURE OF 37mbar THESE APPLIANCES
More informationMesina Fires GLASS FRONT VENTED Model No. M 70
Mesina Fires GLASS FRONT VENTED Model No. M 70 DECORATIVE COAL EFFECT NATURAL VENT GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for
More informationGB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For
O W N E R G U I D E For VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires GB IE This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using
More informationOWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )
5110946/01 OWNER GUIDE Sunfire II Radiant Radiant / Convector Gas Fire Model 347 (G. C. Number 32-032-62) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION
More informationOWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )
5113426/01 OWNER GUIDE Model 739 OPEN DECORATIVE GAS FIRE (GC No. 32-032-54) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). WHEN CONVERTED USING CONVERSION KIT NO. 0595211 THIS APPLIANCE IS FOR USE
More informationSonnet Plus Anthem Genesis Soraya
5110524/01 OWNER GUIDE Sonnet Plus Anthem Genesis Soraya Model 747 (GC No. 32-032-51) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT
More informationSonnet Plus Anthem Genesis Soraya
5108617/01 OWNER GUIDE Sonnet Plus Anthem Genesis Soraya Model 746 (GC No. 32-032-57) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT
More informationModel BR660VA Heat Engine
5112253/01 Model BR660VA Heat Engine POWER FLUE INSET GAS FIRE (GC No. 32-032-44) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). WHEN CONVERTED USING CONVERSION KIT NO. 0591149 THIS APPLIANCE IS FOR
More information(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS
Model Number: V1/100/A V1/100/B (manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE INSTALLATION & USER INSTRUCTIONS GB IE SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE
More informationModel 741FS. Dream, Heritage or Opulent OWNER GUIDE. INSTALLER: Please leave this guide with the owner Baxi Heating U.K. Limited 2007.
5112500/02 Model 741FS Inset live fuel effect gas fire Incorporating the BAXI FIRES DIVISION CONTROL Fitted with one of the following fascia. Dream, Heritage or Opulent (GC No. 32-032-56) We trust that
More informationEmberglow COAL EFFECT BALANCED FLUE GAS FIRE
Emberglow COAL EFFECT BALANCED FLUE GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No. FEBC00MN is only
More informationOWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia
5114465/01 OWNER GUIDE Model 741 INSET LIVE FUEL EFFECT GAS FIRE Fitted with Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia (GC No. 32-032-56) THIS APPLIANCE IS FOR USE WITH NATURAL GAS
More informationMODEL 326 Radiant / Convector Gas Fire Sun~Fire
O W N E R G U I D E MODEL 326 Radiant / Convector Gas Fire Sun~Fire This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using your gas fire and keep for
More informationMODEL 466 Radiant / Convector Gas Fire Black Beauty
I N S T A L L E R G U I D E MODEL 466 Radiant / Convector Gas Fire Black Beauty Please keep in a safe place for future reference 600A734/02 Please leave this Installer Guide with the user This appliance
More informationGB IE INSTALLATION & USER INSTRUCTIONS. Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE
Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE INSTALLATION & USER INSTRUCTIONS GB IE SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE These
More informationOWNER S GUIDE MODEL BR417 VA
600B702/06 OWNER S GUIDE MODEL BR417 VA (G.C.32-032-07) Inset Live Fuel Effect Gas Fire with Ultimate Front AS SUPPLIED, THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING VALOR CONVERSION
More informationGrateGlow THE ALL NEW CAPITAL COLLECTION. G20 at 20mbar convertible to G31 at 37mbar. For use in GB and le. Users Instructions
GrateGlow A CARVER GROUP COMPANY --..--... THE GAS CONSUMERS' COUNCIL (GCC) IS AN INDEPENDENT ORGANISATION WHICH PROTECTS THE INTEREST OF GAS USERS. IF YOU NEED ADVICE, YOU WILL FIND THE TELEPHONE NUMBER
More informationHHG610SS 60cm 4 burner gas hob. HHG710SS 70cm 5 burner gas hob
User Manual for your HHG610SS 60cm 4 burner gas hob HHG710SS 70cm 5 burner gas hob NOTE: This User Instruction Manual contains important information, including safety & installation points, which will
More informationModel 347 BLACK BEAUTY
110945/03 OWNER GUIDE Model 347 BLACK BEAUTY RADIANT / CONVECTOR GAS FIRE (G. C. No. 32-032-62) We trust that this guide gives sufficient details to enable this appliance to be operated and maintained
More informationINSET LIVE FUEL EFFECT GAS FIRE
600B741/02 OWNER S GUIDE MODEL BR650 VA (GC No. 32-032-39) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT NO.591149 THIS APPLIANCE
More informationProline GAS HOB Model TCG40IX Instruction Book
Proline GAS HOB Model TCG40IX Instruction Book GB Operating and Installation Instructions Index Technical data and specifications...... 3 Installation...................... 3-6 Ventilation........................
More informationModel Apex Falcon, Titan & Zenit
Model Apex Falcon, Titan & Zenit Installation and User Instructions All instructions must be handed to user for safekeeping This is not a DIY product and must be installed by a Gas Safe registered installer
More informationmorsø PANTHER GAS STOVE
morsø PANTHER GAS STOVE MODEL No. 553 OWNER S GUIDE This appliance meets the requirements of the European Gas Directive This guide is intended to help you care for your morsø gas stove. It gives sufficient
More informationBelling. Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS
Belling Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS Note: This appliance is supplied for use with Natural Gas and can be converted to LPG
More informationGas Instantaneous Water Heater
6 720 607 823 GB (06.06) SM Installation and Operating Instructions Gas Instantaneous Water Heater WR10..B... WR11..B... With electronic ignition and triple safety system consisting of ionisation detector,
More informationDovre 250 Cast Iron Gas Stove
Dovre 50 Cast Iron Gas Stove NATURAL GAS AND LPG INSTALLATION, SERVICING AND USER INSTRUCTIONS THIS PRODUCT IS FOR USE ONLY IN GREAT BRITAIN AND IRELAND These instructions are to be left with the customer,
More informationINSTALLATION INSTRUCTIONS GB/IE
INSTALLATION INSTRUCTIONS GB/IE Global 55 CF Global 55XT CF Fitting into a Conventional Class 1 Chimney DRU VERWARMING B.V. HOLLAND 957.771.00 CONTENTS Site: 3 Important 3 Foreword 4 Instructions for installation
More informationGAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES PGF 300, 600, 800, 1200
Page 1 of 17 GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES PGF 300, 600, 800, 1200 VALIDATE WARRANTY SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION
More informationKalahari DECORATIVE FUEL EFFECT GAS FIRE
Kalahari DECORATIVE FUEL EFFECT GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No. KRDC00MN & KRDC00SN are
More informationINSTALLATION & USERS INSTRUCTIONS. FOR USE WITH NATURAL GAS 20 mbar For use in GB and IE
1 valentine s buildings Bechers drive Aintree racecourse Business Park L9 5ay CF1 L GAS APPLIANCE INSET CONVENTIONAL FLUED GAS FIRE INSTALLATION & USERS INSTRUCTIONS FOR USE WITH NATURAL GAS G20 @ 20 mbar
More informationEMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE. Installation and Maintenance Instructions
, EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No. FEMC00MN is for use on Natural Gas (G20) at a supply pressure of 20
More informationHOW TO USE YOUR 4500 RANGE L.P.G. COOKER OR HOB UNIT
HOW TO USE YOUR 4500 RANGE L.P.G. COOKER OR HOB UNIT If the appliance does not operate correctly contact your supplier Or Leisure Products (Bolton) Ltd Holly Street, Bolton, BL1 8QR. England. ~~~~ For
More informationINSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550
INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550 Before installation ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the
More informationNIGMA. Fuel Effect Gas Fire INSTALLATION, SERVICING AND USER INSTRUCTIONS. All instructions must be handed to the user for safekeeping
Σ NIGMA Fuel Effect Gas Fire INSTALLATION, SERVICING AND USER INSTRUCTIONS All instructions must be handed to the user for safekeeping Revision A 09/03 Country(s) of destination: GB, IE Focal Point Fires
More informationINSTRUCTIONS MANUAL FOR USE AND MAINTENANCE
INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE Carbel models: C-60 Plus C-70 Plus C-80 Plus C-100 Plus C-70 Plus Double-sided C-80 Plus Double-sided C-100 Plus Double-sided CARBEL C/ Ciudad de Cartagena,
More informationGLOBAL 40 CF FITTING INTO A CONVENTIONAL CLASS 1 CHIMNEY
INSTALLATION INSTRUCTIONS GB/IE GLOBAL 40 CF FITTING INTO A CONVENTIONAL CLASS 1 CHIMNEY DRU VERWARMING B.V. HOLLAND 957.669.00 CONTENTS Site: 3 Important 3 Foreword 4 Instructions for installation 4 Ventilation
More informationBUILT-IN GLASS HOB MODEL: EGH-G8592G(BK) EGH-G8593G(BK) Owner s Manual Please read this manual carefully before operating your set.
BUILT-IN GLASS HOB MODEL: EGH-G8592G(BK) EGH-G8593G(BK) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number
More informationDecorative Fuel Effect Appliances
Decorative Fuel Effect Appliances Technical Manual User and Installation Instructions for CUBB22US Available in Natural Gas. 1 Contents Section Pages 1 Unpacking 3 2 Installation Parameters 4 3 Installation
More informationHOW TO USE YOUR 2500 RANGE L.P.G. COOKER OR HOB UNIT
HOW TO USE YOUR 2500 RANGE L.P.G. COOKER OR HOB UNIT CAUTION These instructions must be read and understood before proceeding with the installation and to avoid any possibility of accident it is essential
More informationOrchestra COAL EFFECT BALANCED FLUE GAS FIRE
Orchestra COAL EFFECT BALANCED FLUE GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No s FBFN76G & FBFN98G are for use on Natural Gas (G20) at a supply pressure
More informationCOAL EFFECT BALANCED FLUE GAS FIRE
Raglan COAL EFFECT BALANCED FLUE GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No. KBFC**MN for use on Natural Gas (G20) at a supply pressure of 20 mbar in
More informationSTRATA BATTERY IGNITION RADIANT CONVECTOR GAS FIRE
STRATA BATTERY IGNITION RADIANT CONVECTOR GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user Model No s FORS**EN are for use on Natural Gas (G20) at a supply pressure
More informationGAS GRIDDLE INSTRUCTIONS MODEL: PGG6 MODEL: PGG7
Page 1 of 17 GAS GRIDDLE INSTRUCTIONS MODEL: PGG6 MODEL: PGG7 SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS TECHNICAL DATA PARTS
More informationGAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES GGP6.4, 6.6, 6.8, 6.10
Page 1 of 18 GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES GGP6.4, 6.6, 6.8, 6.10 VALIDATE WARRANTY SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION
More informationINSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS SALAMANDER
Page 1 of 9 INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS SALAMANDER MODEL : 7072 & 7073 Page 2 of 9 WARNING To avoid scratching the highly polished exterior surface of this
More informationUK/IRL. Saturnus 8 NL CC Heerenveen. P.O. Box 219 NL AE Heerenveen T. +31(0) F. +31(0) < < < <
Saturnus 8 NL - 8448 CC Heerenveen P.O. Box 219 NL - 8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501 56 < < < < PURE (BF80S) SILENCE FEELING SENSE WHISPER SPECTRA NOVA CADRA NOVA MISTY Room-sealed
More informationST900 Direct Vent Gas Fireplace Conversion Kit Manual
ST900 Direct Vent Gas Fireplace Conversion Kit Manual Series 2 Natural Gas for NZ Important: The appliance shall be converted in accordance with; This installation instruction booklet Local gas fitting
More informationInstallation & Service Instructions
Part No. 966/9350/1 02 Potterton Housewarmer Illusion ASD - G.C. NO. 37 590 16 966 Inset DGF with ILLUSION FACIA Potterton Housewarmer Stratton ASD - G.C. NO. 37 590 17 966 Inset DGF with STRATTON FACIA
More informationKalahari RC & Camber RC
Kalahari RC & Camber RC DECORATIVE FUEL EFFECT GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No s KRDC**RN
More informationHUNTER HAWK 4 MKII GAS STOVE
HUNTER HAWK 4 MKII GAS STOVE User Instructions Please leave this instruction booklet with the user after the installation is complete. Leave the system ready for operation and instruct the user in the
More informationHOW TO USE YOUR 2000 RANGE L.P.G. COOKER OR HOB UNIT
HOW TO USE YOUR 2000 RANGE L.P.G. COOKER OR HOB UNIT CAUTION These instructions must be read and understood before proceeding with the installation and to avoid any possibility of accident it is essential
More informationRelaxed Premium M Relaxed Premium M ENG
Relaxed Premium M 40010959 1440 Relaxed Premium M ENG 3 alternative finishes. 1.1a 1.1b 1.1c 1 < < < < 1.2 1.3 7 1.4 2 < < < < 1.5 1.6 B 1.9 3 < < < < 2.1 2.2 2.3 3.1 3.2 3.3 3.4 4 < < < < 3.5 4.1 4.2
More informationModel 956 OWNER GUIDE. This guide to be left with the owner INSET LIVE FUEL EFFECT GAS FIRE
5118756/03 Model 956 INSET LIVE FUEL EFFECT GAS FIRE Fitted with one of the following fascia. Anthem, Aura 2, Blenheim, Bolero, Camden, Capri, Coast, Contemporary, Debut, Flare, Form, Fusion, Homeflame
More informationCRYSTAL FIRES VALENTINES BUILDING BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK LIVERPOOL MERSEYSIDE L9 5AY HEATRAVE S/L DECORATIVE INSET GAS FIRE
CRYSTAL FIRES VALENTINES BUILDING BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK LIVERPOOL MERSEYSIDE L9 5AY HEATRAVE S/L DECORATIVE INSET GAS FIRE THIS APPLIANCE IS CAT I2H FOR USE WITH NATURAL GAS ONLY
More informationPowerVent. Installation manual (GB) English. Store this document in a safe place UK
PowerVent Installation manual (GB) Store this document in a safe place 959.034.03.UK GB Contents Blz Foreword 3 1. Introduction 3 2. CE declaration 4 3. SAFETY 4 3.1 General 4 3.2 Regulations 4 3.3 Precautions
More informationRADIANT / CONVECTOR GAS FIRE MODEL 426 (GC ) INSTALLATION & SERVICING INSTRUCTIONS INSTALLER: Please leave these instructions with the owner
THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) AT A SUPPLY PRESSURE OF 20mbar (8in w.g.) THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM (GB) AND THE REPUBLIC OF IRELAND (IE) RADIANT / CONVECTOR GAS
More informationinstallation and user instructions
installation and user instructions All instructions must be handed to user for safekeeping Revision A - 06/09 Country(s) of destination - GB/IE eko 00 fuel effect gas fire INSTALLATION INSTRUCTIONS Preliminary
More informationBUILD-IN COOKING HOB MODELS H200F, H250F, H400F, 756 & 854F FOR USE WITH LIQUIFIED PETROLEUM GAS
CO UN T RY L E I S U R E BUILD-IN COOKING HOB MODELS H200F, H250F, H400F, 756 & 854F FOR USE WITH LIQUIFIED PETROLEUM GAS USER AND INSTALLATION INSTRUCTIONS WARNING This appliance must be installed by
More informationGAS STAINLESS COOKTOPS
GAS STAINLESS COOKTOPS CG604D & CG905D models CG604DCG905D USER GUIDE HK SG Contents 1 EN Safety and warnings 2 Introduction 5 Using your cooktop 6 Cooking guidelines and cookware 8 Care and cleaning
More informationUBGHFF60W 60cm Gas on Glass Gas Hob
UBGHFF60W 60cm Gas on Glass Gas Hob GB [02] x 1 [03] x 2 [04] x 1 [01] x 1 [08] x 4 [05] x 2 [09] x 1 [06] x 1 [07] x 4 [10] x 4 [11] x 1 TEMPLATE TEMPLATE UBGHFF60W GB Built-in 60cm Gas on Glass Gas Hob
More informationApex Cirrus. Instructions for Trimless kit
Apex Cirrus Instructions for Trimless kit These instructions must be read in conjunction with the main installation guide, the conversion work below should be carried out prior to installing the firebox
More informationCRYSTAL FIRES. Inset Conventional Flue Fire. (BOSTON/MIAMI) Cf1 and MANHATTAN USER INSTALLATION AND SERVICING INSTRUCTIONS
CRYSTAL FIRES (BOSTON/MIAMI) Cf1 and MANHATTAN Inset Conventional Flue Fire USER INSTALLATION AND SERVICING INSTRUCTIONS FOR USE WITH NATURAL GAS G20 @ 20 mbar For use in GB and IE CE THESE INSTRUCTIONS
More informationLUNA 850 V GOLD GAS INSTRUCTION FOR INSTALLATION AND USE. Passion for fire
LUNA 850 V GOLD GAS INSTRUCTION FOR INSTALLATION AND USE Passion for fire SUMMARY 1. GENERAL REMARKS...3 2. CONNECTION...3 3. SPECIFICATION SHEET...4 4. ASSEMBLY OF THE CHIMNEY...5-7 5. ELECTRICAL CONNECTION...8
More informationDOMINATORPLUS G3151 Fusion Range G3150 usion Boiling Top USERS INSTRUCTIONS
DOMINATORPLUS G3151 Fusion Range G3150 usion Boiling Top USERS INSTRUCTIONS SECTION 1 - GENERAL DESCRIPTION SECTION 2 - LIGHTING and OPERATIONS SECTION 3 - COOKING HINTS SECTION 4 - CLEANING and MAINTENANCE
More informationGas Fire Patio Heater Lhotse-817
Gas Fire Patio Heater Lhotse-817 Instruction Manual Please read the manual BEFORE you unpack or install the fire TABLE OF CONTENTS Warning 3 Getting Started 4 What s Included 5 Assembly Procedures 6 Product
More informationBLACK KNIGHT 2 - Classic Collection
BLACK KNIGHT 2 - Classic Collection Installation & Servicing Instructions (GC No. 32 170 16) IMPORTANT - THIS FIRE DOES NOT NORMALLY REQUIRE ADDITIONAL VENTILATION INTO THE ROOM IN WHICH IT IS INSTALLED
More informationINSTALLATION & USER INSTRUCTIONS INSET DECORATIVE GAS FIRE
INSTALLATION & USER INSTRUCTIONS INSET DECORATIVE GAS FIRE MODELS COVERED BY THESE INSTRUCTIONS HANNINGTON BRASS F500310 HANNINGTON BLACK F500311 Focal Point Fires plc. Christchurch, Dorset BH23 2BT Tel:
More informationThis appliance must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.
G3512 and G3532 DOMINATORPLUS Grills INSTALLATION and SERVICING INSTRUCTIONS This appliance must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.
More informationInstallation Manual EF5000 NZ
Installation Manual EF5000 NZ Important: The appliance shall be installed in accordance with; Local gas fitting regulations Municipal building codes AS/NZS 5601.1.1:2010 Gas Installation Any other relevant
More informationDuet Premium M Duet Premium M ENG
Duet Premium M 40011422-1441 Duet Premium M ENG 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1 < < < < 2.1 a 2.1 b 2.1 c A C 2.2 2 < < < < F F 2.3 X H X C 2.4 2.5 S T 3.1 3.2 R Q 3.3 3 < < < < 4.1 4.2 4.3 4.4 4 <
More informationNapoli BF COAL EFFECT BALANCED FLUE GAS FIRE
Napoli BF COAL EFFECT BALANCED FLUE GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user Model No. ABFC**MN2 & ABFC**EN3 are for use on Natural Gas (G20) at a supply
More informationBaxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak
Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak Balanced Flue Gas Wall Heaters Please leave these instructions with the user User s Operating Instructions Baxi Brazilia F 5 Baxi Brazilia F 5S Baxi
More informationOWNER GUIDE MODEL BR622 (GC ) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING. WITH ADORN, VISAGE, ELEGANT or ICON Front
'19 act 2000 6008624/01 May 2000 OWNER GUIDE MODEL BR622 (GC32-032 - 09) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING THE ~ VALOR FireSl~'deCONTROL (E WITH ADORN, VISAGE, ELEGANT or ICON Front THIS APPLIANCE
More informationENIGMA II SLIDE CONTROL Owner's Book
ENIGMA II SLIDE CONTROL Owner's Book INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future
More informationDuet Premium L Duet Premium L ENG
Duet Premium L 40011297-1441 Duet Premium L ENG 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1 < < < < 2.1 a 2.1 b 2.1 c A C 2.2 2 < < < < F F 2.3 X H X C 2.4 2.5 S T 3.1 3.2 R Q 3.3 3 < < < < 4.1 4.2 4.3 4.4 4 <
More informationINSTALLATION INSTRUCTIONS FOR FLUE KIT
INSTALLATION INSTRUCTIONS FOR FLUE KIT HORIZONTAL FLUE TERMINAL ASSEMBLY Ø 80/15 MM 7 719 003 70 FOR GAS CONDENSING APPLIANCES: GREENSTAR CDI SYSTEM/COMBI/REGULAR, GREENSTAR I JUNIOR, GREENSTAR SI, GREENSTAR
More information5traxo INSTALLATION AND SERVICING INSTRUCTIONS MANDATORY REQUIREMENTS INSTALLATION
5traxo Division of Legge Fabheat Ltd Longfield Road, Sydenham, Leamington Spa CV31 1XB Tel. (0926) 882233 Fax (0926) 450846 Registered in England No. 500091 Universal INSTALLATION AND SERVICING INSTRUCTIONS
More informationPARAGON 2000 Xtra SLIDE CONTROL Owner's Book
PARAGON 2000 Xtra SLIDE CONTROL Owner's Book INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy
More informationClassic DECORATIVE FUEL EFFECT GAS FIRE. Installation, Maintenance & User Instructions
Classic DECORATIVE FUEL EFFECT GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user Model No s CSRC**MN is only for use on Natural Gas (G20) at a supply pressure of
More informationClarendon and Ashdon Log Effect Stove Range
Clarendon and Ashdon Log Effect Stove Range Conventional Flue With upgradeable control valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) This appliance has
More informationUSHO COOKER INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL: USHO. INSTRUCTION REF: IN152 ISSUE No. 4 DATE
Page 1 of 11 INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS USHO COOKER MODEL: USHO Page 2 of 11 WARNING To avoid scratching the highly polished exterior surface of this equipment whilst
More informationBALANCED FLUE LOG EFFECT GAS FIRE
Celena BALANCED FLUE LOG EFFECT GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user Model No s BCBL**RN is only for use on Natural Gas (G20) at a supply pressure
More informationINSTALLER GUIDE COALFLAME & LIMOUSIN. MODEL BR627 (GC No ) INSET LIVE FUEL EFFECT GAS FIRE
600B607/05 INSTALLER GUIDE COALFLAME & LIMOUSIN MODEL BR627 (GC No. 32-032-22) INSET LIVE FUEL EFFECT GAS FIRE AS SUPPLIED, THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING VALOR CONVERSION
More information5. Wok setting (wok burner) 6. Roasting setting (wok burner)
OPERATION Description 6 5 7 8 9 0 Ignition and adjustment. zone indication. 0 position. High setting. Low setting 5. Wok setting (wok burner) 6. Roasting setting (wok burner). rapid burner. standard burner.
More informationJANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No
JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No 53 416 06 Publication No. ZZ 180/17 May 2000 These appliances are tested and certified by B G Technology for
More information