Installation Manual. Instrucciones de instalación y manual de usuario 1
|
|
- Maurice Parks
- 5 years ago
- Views:
Transcription
1 Installation Manual Instrucciones de instalación y manual de usuario 1
2 Installation instructions and user manual V8 2
3 INDEX 1 GENERAL SAFETY WARNINGS OPERATING PRINCIPLE TECHNICAL FEATURES INSTALLATION USAGE RULES MAINTENANCE, REPAIR AND CLEANING TROUBLESHOOTING Installation instructions and user manual V8 3
4 1 GENERAL SAFETY WARNINGS To avoid any injury to the user as well as material damage, the following instructions shall be followed. Incorrect operation due to ignoring these instructions may cause damage and invalidate the warranty. The installation is the responsibility of the purchaser. Read the information supplied with the equipment carefully before installing and using it. The manufacturer declines any responsibility as regards damages deriving from an incorrect installation and a failure to follow the instructions detailed here. Ask a suitably qualified installer to install this equipment as incorrect installation may cause gas and water leaks, electrical discharges etc. Do not install the equipment in the following places as they may bring cause malfunctioning of the equipment: areas with corrosive gases, factories where the electrical voltage experiences wide fluctuations, places with strong electromagnetic waves, places with inflammable materials or gases, other special environments. The electrical connection has to be carried out in accordance with that specified in the manual. It is vital to install the safety group and check that it is working properly. Sufficient space shall be set aside for installation and maintenance including the connections of pipes and wiring. The equipment shall always remain in a horizontal position during transport, transfer and installation. The support surface shall be flat, bear the weight of the unit and be ready for the installation of the unit without increasing noise or vibrations. Maintenance repairs and tasks shall be carried out by a professional technical service. An incorrect maintenance task or repair may bring about gas and water leaks, electrical discharges etc. Warning! Legionella disaffection in the existing cylinder. It is important that the existing immersion heater in the existing cylinder has a programmable timer added to it so that the immersion heater will be set to come on weekly and keep the temperature of the hot water to 65 degrees for at least 15 minutes. The main water should to be soft water. Hard waters (CaCO3 content >200 ppm) may produce obstructions due to the lime deposits inside the system. For hard water it is recommended to use a descaler in the hydraulic circuit. It is vital to install an appropriate filter in the hydraulic circuit. in order to prevent the entry of solid particles in the system which could damage it Alternatively the existing boiler may be used to raise the water temperature to 65 degrees for a minimum period of 15 minutes on a weekly basis. HEALTH & SAFETY: Care should be taken when moving any appliance. Check the weight before any lifting. This is for the safety of the installer and customer. Ensure the appliances and in particular the box are installed in a safe location and the mounting structure is adequate to withstand the additional loads. Take care when moving equipment to ensure there is no damage to the equipment or existing structure and fittings. Installation instructions and user manual V8 4
5 2 OPERATING PRINCIPLE The Green e-pack I is an innovative solution to cover the demand for domestic hot water in properties and houses that already have a cylinder installed. The system is extremely easy to install, as it connects to the water tank s flow and return connections and provides hot water continuously. This is a compact unit which includes all the elements of the heat pump as well as the inner heat exchanger. The built-in fan uses the air from inside the living space and transmits it to the water that pumps to storage cylinder. When leaving the air can be conducted to the outside via ventilators thanks to its connection. Installation instructions and user manual V8 5
6 3 TECHNICAL FEATURES TECHNICAL FEATURES- THE GREEN E-PACK I Mean thermal capacity (only thermodynamic) (W) 2000 Min to Max Mean power consumed (thermodynamic) (W) Voltage / frequency 300 to V / I ph / 50 Hz Atmospheric temperature range (ºC) 0 to 45 COP range Refrigerant fluid R134a DHW temperature range with thermodynamics (ºC) 55 Dimensions (height x width x depth) (mm) 645mm x 425mm x 345mm Maximum working pressure (bar) 8 Cold water input connections (") /Hot water output connections (") 1/2-1/2 Power Fan (W) 45 Installation instructions and user manual V8 6
7 Fig. 1 DESCRIPTION SCHEMATIC GREEN E-PACK (upper view) A. Water outlet 1/2 B. Water inlet 1/2 C. Condensate drain pipe D. Temperature probe E. Electric connection Installation instructions and user manual V8 7
8 4 INSTALLATION Order of assembly The installation is carried out in accordance with the steps detailed below: 1. Green e-pack Fitting 2. Hydraulic connections 3. Exhaust air connection 4. Temperature Sensor 5. Electrical connections 6. Draining of the hydraulic circuit 7. Turning the system on 4.1. GREEN E-PACK FITTING Siting location Before proceeding with the installation of the unit check that the place where The Green e-pack will be placed has: Sufficient space for the electrical and hydraulic connections. This apparatus is designed for assembly in horizontal position and should not be installed in any other position. The equipment shall not be installed in an environment with potential exposure to corrosive gases, factories where the electrical voltage experiences major fluctuations, places with sources of electromagnetic waves, inflammable materials or gases or other special environments. Minimum volume required for the room is 21m3 allowing air recycling. It is not recommended the installation in places with risk of icing. The maximum distance between the Green e-pack and the existing water cylinder is 8 metres. Using an 18mm minimum pipe size and having no more than, 10 elbows, 2 T connectors and 4 valves. It is recommended that the minimum number of accessories is used (elbows etc) and that the Green e-pack is placed as close to the existing cylinder as possible in order to provide optimum system performance. It is recommended that the Green e-pack is fitted at least 20cm below the water level of the water cylinder. This is a precautionary measure to avoid air lock in the pump. On vented systems an AAV (Auto Air Valve) should be positioned to avoid risk of air in the pump. If installed above the cylinder an additional water pump may be installed between the cylinder outlet and Green e-pack inlet of not less power than the 45w pump installed in the Green e-pack. Installation instructions and user manual V8 8
9 This is to avoid gravity removing the water from the pump. The pump must be suitable for sanitary hot water. Additionally a second automatic air vent may be required to be between the cylinder outlet and Green e-pack inlet, close to the inlet. Sanitary hot water outlet is always recommended to be above the water feeding to the Green e- Pack Handling when moved The equipment must be transported and moved in an upright horizontal position and should never be turned over or put sideways. Should this happen then we recommend leaving the unit in the horizontal position for 24 hours before installing. We also advise to proceed with caution. During the unloading and movement of the unit the instructions in this manual shall be strictly followed with a view to ensuring the safety of the unit and people. Otherwise there may be a risk of injury or material damage. Incorrect installation or procedures may invalidate the warranty. During its handling care should be taken to ensure it shall not be submitted to sudden movements or blows, in order to avoid damage. Installation The installation should be carried out in accordance with the steps detailed below: 1/ Anchor the plate to a suitable solid wall with four M8 screws. A vibration pad may be required if fixing to an internal partition wall. 2/ Carefully, insert the Green e-pack into the plate through the gaps. Fig. 2 Green e-pack I Fitting 1/ 2/ Installation instructions and user manual V8 9
10 4.2. HYDRAULIC CONNECTIONS The Green e-pack has a mains water inlet and hot water outlet located on the bottom part of the box (see Fig1 ). The minimum pipe size of the hydraulic circuit is 18mm Ensure the pressure of the hydraulic circuit is at least 1kg (see Fig 8, pressure gauge) It is responsibility of the installer to put in T connections in the water inlet and water outlet connections of the cylinder / buffer tank. The installer should assemble the proper filter, pressure guage, draining element, expansion vessel and security group according to the scheme showed in fig 8, 9 and 10. It is recommended to fit the Green e-pack at least 20cm below the water level of the water cylinder. Sanitary hot water outlet should always be above the water feeding the Green e-pack. Flexihose pipes should not be used as they restrict the water flow. A non-return valve must be installed. In a vented system ensure that the water pressure is sufficient to open the valve otherwise air may be sucked into the system. In these circumstances a flap style valve may be suitable. The hydraulic system will vary dependant on the existing type of cylinder/buffer tank. The following figures show the steps for installing buffer tanks with two connections, and two or more connections: Do not fit the pipes to an existing coil in the cylinder, this will stop the Green e-pack reaching maximum temperature. Installation instructions and user manual V8 10
11 FLOW RATE VARIATION PLOTTED WITH DISTANCE Assuming no more than 10 elbows, 2 T connections and 4 valves Length (m) Q (m3/h) Q (l/s) Fig 3. T connection on water pipe from cylinder leading to Green e-pack inlet Installation instructions and user manual V8 11
12 Figure 4. Installation in tanks with 2 connections Green e-pack It is recommended to fit Green e-pack below water level in the cylinder, 20 cm at least Installation instructions and user manual V8 12
13 . Figure 5 Installation in tanks with 2 or more connections It is recommended to fit Green e-pack below water level in the cylinder, 20 cm at least Installation instructions and user manual V8 13
14 It is recommended to fit Green e- Pack below water level in the cylinder, 20 cm at least Installation instructions and user manual V8 14
15 4.3. EXHAUST AIR CONNECTION In the top of the equipment is located the connection to the exhaust air, to connect with a 120 mm elbow and the exhaust duct, not exceed a pressure drop of 50 Pa. FIGURE 7 AIR DUCTS (Where appropiate) Accessory Maximum duct lenght - 6 m 1 elbow 90ºC 5 m 2 elbow 90ºC 4 m 3 elbow 90ºC 3 m 4.4. TEMPERATURE SENSOR Attach the supplied temperature sensor to the cylinder / accumulator tank. It is recommended to place it on the middle of the cylinder / tank. The wire can be extended on installation if required. It is recommended to follow the manufacturer's instructions, which indicate the location and method of installation of the probe 4.5. ELECTRICAL CONNECTIONS The equipment shall be connected to the electrical system when all the refrigerant connections have been made. The power supply is single phase: 230V / 50Hz with earth connection. The electrical schematic of the equipment has been shown in the following figure: Installation instructions and user manual V8 15
16 Fig. 8 WIRING DIAGRAM Installation instructions and user manual V8 16
17 4.6. DRAINING OF THE HYDRAULIC CIRCUIT Once the installation is complete the water cylinder should be checked to ensure that it is full of water and free from air. Open the valves and hot water taps in order to remove any air from the circuit. Wait until all air is drained. Close the valve No1 (Fig 8 and 9) and keep the taps open. Wait until all air is drained. Open the valve No1 (Fig 8 and 9) and close the tap TURNING THE SYSTEM ON The Green e-pack may be started once the steps described previously have been completed. To turn the Green e-pack on, connect to the electrical system The Green e-pack, once connected, shall operate automatically thanks to the digital controller which shall start up when the temperature falls below the prefixed value. Fig. 9 Control panel scheme Installation instructions and user manual V8 17
18 5 USAGE RULES 5.1. TEMPERATURE ADJUSTMENT The digital thermostat of the equipment marks the temperature of the water at any time. This thermostat is preset at 55ºC. - To view the set point temperature of the compressor, press the SET button. To modify the adjustment temperature leave the SET button pressed for 7 seconds, SP be displayed. Using the buttons with the arrow pointing upwards / downwards we can increase / reduce the set point temperature. Once set, press the set button again. The temperature range is from 20 to 55ºC. Press ESC to cancel. The compressor will raise the temperature to 55C when it will cease working. It will automatically cut in to raise the water temperature once it falls to 50C. WARNING: The programmed temperature for the compressor should never exceed 55ºC Fig.10 Digital thermostat scheme. OPERATING: DESCRIPTION SET BUTTON UP BUTTON DOWN BUTTON ACTION Keep pressed down for 7 seconds to change the operating temperature of the compressor Increases the temperature Decreases the temperature COMMENTS The temperature of the compressor is pre-set at 55 C Never exceed 55 C. Installation instructions and user manual V8 18
19 Once the temperature is set; press the SET key again To modify the temperature follow the instructions in diagram 11. Fig. 11 Operating the digital thermostat Installation instructions and user manual V8 19
20 6 MAINTENANCE, REPAIR AND CLEANING WARNING. Follow the general warnings and safety rules listed at the start of the text carefully, paying due attention to everything which is indicated. All maintenance operations and interventions shall be carried out by qualified staff. Check that any operating failure does not depend on other causes such as, for example, a temporary lack of water or electrical energy. The siting of the unit must be dry, clean and well-ventilated. Any inspection or work must be carried out by authorized installers checking: - The proper operation of the installation, the regulator and the safety devices. It is vital to empty the apparatus if it has to remain out-of-use for a prolonged time period. Where necessary, empty the apparatus as indicated below: - disconnect the apparatus from the electrical system; - turn off the stop cock of the domestic installation; - turn on the hot water tap (sink or bath); If the installation is in a hard water area limescale may be deposited inside the system. In this situation it is recommended that a descaler is included in the hydraulic circuit and periodic inspections made to ensure the cleanliness of the system. Installation instructions and user manual V8 20
21 8 TROUBLESHOOTING First of all, it is recommended to check the gas pressure of the system. Measure the evaporation pressure and ensure that the respective evaporating temperature is 10-15ºC below the ambient temperature. Problems Causes Solutions Lack of power Check the power supply Check that the power switch is on The screen doesn t show any information High Pressure switch is on Check the R134a load Check that the pressure switches function properly Screen error Check that the screen functions properly Incorrect gas load Check the R134a load The system starts and stops, the screen switches off Obstruction in the hydraulic circuit High Pressure switch is on Non condensable gases in the refrigeration circuit Verify the cleanness of the hydraulic circuit Check that the pressure switches function properly Lime deposits inside the hydraulic circuit: Change the filter of the hydraulic circuit and clean the whole system Check the proper working of the water pump, draining any air that is inside Check the R134a load Empty the refrigeration circuit E1 error appears on screen Temperature probe Check the temperature probe connection Check the continuity of the probe using a multimeter AE error appears on screen Low pressure switch is open Gas leak: Check for leaks in the refrigerating circuit Check water pump for air and drain accordingly Check the R134a load Installation instructions and user manual V8 21
22 Problems Causes Solutions The water is cold and the compressor is working Incorrect gas load Adjustment of the water temperature The temperature sensor is disconnected to the cylinder The hydraulic circuit is not isolated properly Check the R134a load Check the temperature adjustment on screen Check the right placement of the temperature sensor inside the cylinder Check the proper isolation of the hydraulic circuit and the cylinder The water temperature is slow to recover Refrigerant Leak or Load Poorly Insulated Tank Check for leaks. If pipe run over 8 metres extra refrigerant must be added Add insulation Installation instructions and user manual V8 22
23 Energy Panel S.L. Ctra. Lucena-Loja, km. 1,7 Teléfono: Fax: Apdo. de correos Lucena (Córdoba) ESPAÑA Installation instructions and user manual V8 23
Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES
Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES 1 1 2 3 Once again, the Energy Panel team has put all their excitement and enthusiasm to create this new publication. We want to make
More information3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS
3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: 32305600 OPERATION & MAINTENANCE INSTRUCTIONS 0304 Parts List Item Part No Description Qty 1 FT900001 Top Cover 1 2 FT900002 Filter
More informationPLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL
PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION SOLARCYL IM/SC INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented
More informationProducts catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES
Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES 1 2 3 Heat Merchants have partnered with Energy Panel to offer the most advance technology in Thermodynamic Solar Systems for both residential
More informationProduct catalogue 2014 INNOVATIVE IDEAS FOR SMART SAVING
Product catalogue 2014 INNOVATIVE IDEAS FOR SMART SAVING Once again, the Energy Panel team has put all their excitement and enthusiasm into creating this new publication. We want to make you aware of technology,
More informationINSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION
PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION Ecoline Geo RI HP INSTALLATION MANUAL The Ecoline GEO is an indirect unvented cylinder designed and approved for use with a heat pump. The
More informationInstallation, Operating and Servicing Instructions
ENGLISH 0 / 0 / 0 / 0 / 00 Installation, Operating and Servicing Instructions FRANCAIS NEDERLANDS ESPAÑOL Y000.A EN ESPAÑOL NEDERLANDS FRANCAIS ENGLISH INDEX WARNING Who should read these instructions
More informationInstallation, Operating and Servicing Instructions
EN 0 / 0 / 00 / 800 Installation, Operating and Servicing Instructions excellence in hot water EN Y000.D EN INDEX Warnings Who should read these instructions Symbols Recommendations Applicable standards
More informationAir-Water heat pump Small GT
Catalogue No.... KJ... Production date... Installation and operation manual Air-Water heat pump Small GT The heat pump generates DHW at a maximum temperature of 50 C Distributor: ver. 21/04/2015 Please
More informationUnvented Calorifier Range. Operating and Maintenance Manual. For Models & 500
Unvented Calorifier Range. Operating and Maintenance Manual. For Models 125 300 & 500 Telephone 08456 448802 Fax 08456 448803 Emial info@mhgheating.co.uk Web www.mhgheating.co.uk TABLE OF CONTENTS. Section
More informationAUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS
AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS Dear Customer, Congratulations on having chosen a quality product which will certainly fully meet your expectations. Thank you for having purchased
More informationInstallation, operating and servicing instructions
English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationPortable Air Conditioner. Instruction Manual
Portable Air Conditioner Instruction Manual YPL3-08C Please read the instructions completely before using this product This product is designed for household use only. FOR SERVICE : CALL TRANS GLOBAL SERVICE
More informationAUTOMATIC MODULAR ICE-CUBE MAKER
AUTOMATIC MODULAR ICE-CUBE MAKER INSTRUCTIONS AND WARNINGS 24851 ed. 06-2012 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationSpectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents
Installation, Service & Operation Manual SoftH 2 O FLO Water Softener Table of Contents 1. Description & Equipment Adjustments p.2 2. Components, Features & Functions p.3 3. Valve User Interface p.4 4.
More informationPC20-AMFII / PC40-AMF USER MANUAL
VERY IMPORTANT PC20-AMFII / PC40-AMF USER MANUAL Please read this instruction guide before install and using your portable air conditioner unit. This instruction manual is the universal-purpose version
More informationINSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM
INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM Thank you for choosing a DOMUSA TEKNIK heating boiler. Within the product range offered by DOMUSA TEKNIK you have chosen BioClass HM model. With a suitable
More informationAUTOMATIC GRANULAR ICE FLAKER
AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24480 rev. 01 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on choosing a
More informationPLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL
PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION 0 RD 0 RI 0000-06 IM/ IM/a INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting
More informationEURO APPLIANCES BY EUROSTYLE GROUP
Beverage Cooler EBC 600SX1 EURO APPLIANCES BY EUROSTYLE GROUP Warning The information in this document is subject to modification without any prior notice. This beverage cooler is recommended for indoor
More informationIMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring
Page 1 of 8 IMAGINATION SOLAR LTD Installation Guide B1 Planning the Plumbing and Wiring Unit 4 Montpelier Central, Station Road Bristol BS6 5EE t: 0117 942 6668 f: 0117 942 8998 e: enquiries@imaginationsolar.com
More informationSHERPA. Air-water split heat pump. COP > 4 ACS a 60 C
Air-water split heat pump. COP > 4 ACS a 60 C Energy class: 35 55 RENEWALE TECHNOLOGIES Sherpa uses the heat in the air, and transfers it to system terminals in an efficient manner. For each kw of electricity
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationUSER MANUAL ACQUAHOME 32 B BLU
USER MANUAL ACQUAHOME 32 B BLU Dear Customer, Thank you for preferring a T heating unit, a modern, high-quality product that is able to guarantee your maximum well-being for a long period of time, with
More informationSEALED THERMAL STORE
ISSUE 3 0717 INSTALLATION AND USER GUIDE ENERGYMANAGER SEALED THERMAL STORE ADVANCE APPLIANCES LTD PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. SCHEMATIC DIAGRAM OF ENERYMANAGER THERMAL
More informationDEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST
COMFORT...BUILT TO LAST 11 PINT DEHUMIDIFIER USER MANUAL FOR MODEL: 3PAD11 Before using your dehumidifier, please read this manual carefully and keep it for future reference, along with your receipt. CONTENTS
More informationLCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS
Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose
More informationMURELLE EV HE 25/55-30/55
UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION MURELLE EV HE 25/55-30/55 User instructions 199838 Please read the Important Notice within this guide regarding
More informationCLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL
CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. SAFETY INSTRUCTIONS Important! Carefully
More informationInstallation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual Packaged Chiller Models CC 6601, 6501, 6401, 6301, 6201, 6101 For Service, please contact Pfannenberg Service Company: U.S.A. Pfannenberg Inc. 68 Ward Road.
More informationTHROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H
THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER Instruction Manual Model AMB-12H PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS UNIT. Table of Contents 1. SAFETY WARNINGS 2 2. CONSTRUCTION...
More informationMODULAR AUTOMATIC GRANULAR ICE FLAKER
MODULAR AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 03 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having
More informationTOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS
TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and
More informationDIGITAL MODULATING BOILERS
DIGITAL MODULATING BOILERS FOR HEATING AND SANITARY HOT WATER CMX15 CMX18 CM15 CM18 INSTALLATI INSTRUCTIS AND USER GUIDE Please read these instructions before installing or using this appliance for the
More informationUser instructions DHP-AT
User instructions DHP-AT VUGFC202 If these instructions are not followed during installation and service, Danfoss A/S liability according to the applicable warranty is not binding. Danfoss A/S retains
More informationAUTOMATIC MODULAR ICE FLAKER
AUTOMATIC MODULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 08 It is strictly forbidden to reproduce this instruction manual or any part thereof. 1 5 3 4 Mod. N. V. W 2 2 M8 18 8 18 M8 M8 3 ~ 200
More informationPasto Sous vide water bath
Pasto Sous vide water bath User Manual enquiries@grancreativecuisine.com User guide Page 1 If you have any feedback on Grant Creative Cuisine s products or services, we would like to hear from you. Please
More informationInstallation, operating and. Comfort
EN Installation, operating and servicing instructions Comfort 00-0 - 60-20 - 20 TABLE OF CONTENTS EN GENERAL Notes Certification CE Standards Packaging SAFETY PRECAUTIONS 5 Symbols used 5 Recommdations
More informationAUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM
AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM INSTRUCTIONS AND WARNINGS 24481 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear
More informationCombi Konverter Solar System
Installation Manual Combi Konverter Solar System Issue 1 These instructions are specific to the integration of the RMSolar Combi Konverter system with the combi boiler. The RMSolar instructions should
More informationCOMPACT PORTABLE AIR CONDITIONER USER MANUAL
COMPACT PORTABLE AIR CONDITIONER USER MANUAL Thank you for choosing ElectriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page
More informationPRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.
PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 00 m /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION
More informationSPA DE USO PRIVADO SPA FOR PRIVATE USE SPA POUR UN USAGE PRIVÉ SPA FÜR PRIVATE NUTZUNG SPA PER USO PRIVATO SPA PARA USO PRIVADO SPA VOOR PRIVE-GEBRUIK
SPA DE USO PRIVADO SPA FOR PRIVATE USE SPA POUR UN USAGE PRIVÉ SPA FÜR PRIVATE NUTZUNG SPA PER USO PRIVATO SPA PARA USO PRIVADO SPA VOOR PRIVE-GEBRUIK MANUAL DE INSTALACIÓN INSTALLATION MANUAL MANUEL D
More informationARTICA. 8000Btu. Room Air Conditioners Portable Range
UK ARTICA 8000Btu Room Air Conditioners Portable Range INDEX Congratulations! You have purchased the very latest in room air conditioning technology. Your new EcoAir high efficiency room appliance will
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationCROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15
CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 COMPACT PLUS 10 and 15 Litre Unvented Under and Over Sink Water Heater INSTALLATION AND USER GUIDE 1 DIMENSIONS 10L - 250mm 15L - 310mm 100mm 80mm 410mm
More informationInstallation and Commissioning Manual
Manual Advance Buffer Vessels for Ground Source Heat Pump Systems Installation and Commissioning Manual Copyright 2015 Kensa Heat Pumps Ltd Page 1 of 12 Contents Page Section Description Page 1... Safety
More informationaurostor Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VIH S GB...
Installation and maintenance instructions For the competent person Installation and maintenance instructions aurostor VIH S GB.../3 GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-4859
More informationUser Manual for model
User Manual for model RKA 24 /20 Wall mounted storage combi boiler premix condensing boiler CE 0694 Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate RKA 24.20 - RAD - ING - MAN.UT - 1309.1
More informationTrade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2
Trade of Plumbing Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2 Table of Contents List of Figures... 4 List of Tables... 5 Document Release History... 6 Module 2 Domestic
More informationINSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16
INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358,
More informationSHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C
SHERPA Th e multifunctional air-water split heat pump. PATENTED TECHNOLOGY The combination of an inverter air-water heat pump together with a water-water heat pump allows heating/ and high temperature
More informationResidential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...
70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................
More information10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W
10L Dehumidifier Model Number: LDH1001 220-240V AC 50/60Hz 290W For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am 8pm & Saturday 9am 1pm Or visit us at www.productcare.co.uk
More informationSafety. Connect the product properly to the ground. (Malfunctioning or power leaks can cause electrical shock.)
User s Manual TEVHR Contents Safety...1 Control List...2 Components...3 Dimensions...3 Installation...4 Technical Specification...5 Electrical Connection...6 Electrical Scheme...7 Maintenance...10 Control...11
More informationDOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS
DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS Today s inescapable need to improve energy efficiency in UK homes has brought installers many opportunities to make extra earnings through the upgrading
More informationUSER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES
24-28Si II SERIES G.C. NUMBERS APPLIANCE NATURAL GAS L.P.G. 24Si II 47 311 65 47 311 66 28Si II 47 311 67 47 311 68 USER INSTRUCTIONS & CUSTOMER CARE GUIDE EXCELLENCE COMES AS STANDARD CONTENTS Page No.
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationUnvented Electric Water Heater 10/15 litre Undersink
Unvented Electric Water Heater 10/15 litre Undersink Fitting Instructions and User Guide 1 CONTENTS SECTION PAGE 1.0 INTRODUCTION 2 2.0 TECHNICAL SPECIFICATION 3 3.0 INSTALLATION 4 4.0 COMMISSIONING 9
More informationIndex BEFORE USING THE APPLIANCE Safety Instructions... 2 Recommendations... 3 Switching On the Appliance... 4 HOW TO OPERATE THE FREEZER...
Index BEFORE USING THE APPLIANCE... 2 Safety Instructions... 2 Recommendations... 3 Switching On the Appliance... 4 HOW TO OPERATE THE FREEZER... 5 Thermostat Setting... 5 Display Panel... 5 FOOD STORAGE
More informationFurrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE
WATERHEATER MANUFACTURERS ASSOCIATION Tel 01952 257963 Fax 01952 253452 Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE www.telford-group.com STAINLESS PRODUCTS Tornado &
More informationINSTALLATION, COMMISSIONING AND OPERATING MANUAL
INSTALLATION, COMMISSIONING AND OPERATING MANUAL 1 YTBV-D-CE42_0109 CONTENT Available models and capacities Supplier information Warranty Safety Emergency stops/ shutdowns About this manual Models Physical
More informationENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER
ENERSTORE Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER Newark Copper Cylinder Co Ltd Brunel Drive Newark Notts. NG24 2EG Tel: 01636 678437 Fax: 01636 678964 Internet: www.newarkcoppercylinder.co.uk
More informationPLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions
GB PLEASE LEAVE THIS INSTRUCTION WH THE USER ECOMFORT PLUS 25 HE User instructions All descriptions and illustrations provided in this manual have been carefully prepared but we reserve the right to make
More informationPortable Air Conditioner USER MANUAL
AC12 AC12HP Portable Air Conditioner USER MANUAL Thank you for choosing this innovative Amcor air conditioner. We suggest that you keep this manual in a safe place for future reference. It describes the
More informationAUTOMATIC ICE-CUBE MAKER
AUTOMATIC ICE-CUBE MAKER INSTRUCTIONS AND WARNINGS 24478 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having chosen
More informationGrant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions
Grant Aerona³ Air to Water High Efficiency Heat Pump Range User Instructions UK DOC 0112 Rev 1.0 April 2017 Special Tex t Formats The following special text formats are used in this manual for the purposes
More informationMidea Ducted and Cassette Split Systems. Maximum versatility, maximum value.
Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.
More informationOwners Manual Refrigerated Air Dryer MHT SERIES
Owners Manual Refrigerated Air Dryer MHT SERIES IMPORTANT: READ THIS MANUAL CAREFULLY. IT CONTAINS IN- FORMATION ABOUT SAFETY AND THE SAFETY OF OTHERS. ALSO BECOME FAMILAR WITH THE PROPER INSTALLATION
More informationUnstirred Water Baths
Unstirred Water Baths JB Academy JB Nova SUB Aqua Pro Operating Manual sales@grantinstruments.com Tel: +44 (0)1763 260811 Detailed operating manual Page 3 If you have any feedback on Grant s products or
More informationOIL COOLER INSTRUCTION HANDBOOK
OIL COOLER INSTRUCTION HANDBOOK INDEX 1. GENERALITY 2 1.1 OPERATING RANGE 1.2 IMPORTANT 2. INSTALLATION 3 2.1 TRANSPORTATION 2.2 INSTALLATION LOCATION 2.3 PIPING 2.4 WIRING (see the electrical diagram
More informationUnvented Direct & Indirect Hot Water Cylinders (400L L)
Unvented Direct & Indirect Hot Water Cylinders (400L - 2500L) Important Please read & understand all these instructions before commencing installation. Please leave this manual with the customer for future
More informationUSER MANUAL TPS-M5/M55/M555
VERY IMPORTANT Please read this instruction guide before install and using your mini portable type air conditioner unit. This instruction manual is the universal-purpose version for the units that you
More informationINSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3
INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWE50AV EKHWET50AV EKHWE00AV EKHWE00AV EKHWE00AZ EKHWE00AZ 4 5 6 7 x x x 4x x x x EKHWE50~00 EKHWET50 50 50 0 0 00 50 700
More informationEDD61 & EDD91 Extractors
EDD61 & EDD91 Extractors Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu
More informationStainless Steel Chimney Extractor
Stainless Steel Chimney Extractor HJA2450-2 User & Installation Guide LAMONA Appliances Dear Customer, Congratulations on your choice of a LAMONA domestic appliance which has been designed to give you
More informationSweden s leading air source heat pump
- Since 1939 ExoAir / ExoAir Polaris GreenEnergy Sweden s leading air source heat pump BEST IN TEST The Swedish Energy Council recently scored the Euronom air source heat pump as the leading product of
More informationInstallation, operation and maintenance instructions. HRi Y1300-A
Installation, operation and maintance instructions HRi 321-601 - 800 Table of contts Geral Recommdations...4 User's Guide...5 Control Panel... 5 Appliance Description...6 Models - HRi 321 601-800... 6
More informationPORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER Model: PEL00460 1 CONTENTS Page No. Details 2 Important Safety Information 3 Product Overview 3 Positioning & Installation 4 Installation Errors 4 Control Panel 5 Screen IMPORTANT
More informationPLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions
GB PLEASE LEAVE THIS INSTRUCTION WITH THE USER Ecomfort 30 HE User instructions CONTENTS OPERATING INSTRUCTIONS FOR THE USER 1.1 INTRODUCTION.................................................................................
More informationStainless Steel Chimney Extractor
Stainless Steel Chimney Extractor User & Installation Guide LAM2404 LAMONA Appliances Dear Customer, Congratulations on your choice of a LAMONA domestic appliance which has been designed to give you excellent
More informationExtreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09
I N S P I R E D E F F I C I E N C Y Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION Issue 11/09 Technical data Description Extreme 200 Extreme 300 Extreme 500 Weight (empty) kg 63 77
More informationAIR SOURCE HEAT PUMPS DUAL CLIMA
AIR SOURCE HEAT PUMPS DUAL CLIMA COMPACT MONOBLOC HEAT PUMP COMPLETE INSTALLATION SOLUTION PACK (HEATING, COOLING AND DHW) FULLY RATED HEATING CAPACITY GUARANTEED TO -20ºC CAN BE COMBINED WITH OTHER ENERGIES
More informationTABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses
INSPIRED H I G H H O T EF F ICIENCY E F F I C I E N C Y W A T E R S Y S T E M S E XT REME HIGH EFFICIENCY HO T W AT ER SY ST EMS w i th I N JECT I O N DYN A M I C S T ECHN I CAL DO CUME N TA T I O N I
More informationADDITIONAL FUEL STORAGE CONTROLLER MP-01
ADDITIONAL FUEL STORAGE CONTROLLER MP-01 page 2 Index Index 1 General information 4 1.1 Introduction 4 1.2 Contents 4 1.3 Safety precautions 5 1.4 Disposal of old equipment 6 2 Connecting to the system
More informationOPERATING INSTRUCTIONS
EN DEHUMIDIFIER OPERATING INSTRUCTIONS Read the instructions carefully before operating or servicing the dehumidifier. Observe all the safety instructions; failure to observe the instructions may lead
More informationCBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet
CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that
More informationSLTC919 UNDERMOUNT RANGEHOOD INSTALLATION INSTRUCTIONS
Congratulations on your purchase! Thank you for choosing a Sirius product. SLTC919 UNDERMOUNT RANGEHOOD INSTALLATION INSTRUCTIONS SLTC919 520 EAN # 9351116002244 SLTC919 580 EAN # 9351116002251 www.siriusbrand.com
More informationUnvented Direct & Indirect Hot Water Cylinders (400L L)
Unvented Direct & Indirect Hot Water Cylinders (400L - 2500L) Important Please read & understand all these instructions before commencing installation. Please leave this manual with the customer for future
More informationUSER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE:
USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE: 0870 428 0075 CONTENTS Page 2 - Unpacking Page 3 - Heating system preparation and
More informationDEHUMIDIFIER INSTRUCTION MANUAL
MODEL: OBZ-50DHPN CONTENTS SAFETY PRECAUTIONS Warning...2 Caution...2 Electrical information...3 DEHUMIDIFIER CONTROLS Control panel...4 Other features......5 DESCRIPTION OF PARTS Identifying the parts.......6
More informationC C C-600 INSTRUCTION MANUAL ICE CUBES MACHINE. (including: exploded views, part list & diagrams) CUISIMAT
C-250 - C-400 - C-600 INSTRUCTION MANUAL ICE CUBES MACHINE (including: exploded views, part list & diagrams) Art.no.: *706.025 / *706.040 / *706.060 1 CONTENTS PRECAUTIONS... 2 INSTALLATION... 3-4 OPERATION...
More informationUser Guide Compact-7 series
User Guide Compact-7 series Boiler-CH Calorifier Combi Introductory remarks Congratulations on the purchase of your Kabola Compact 7. Kabola has been a manufacturer of oil-fired heating systems since 1947.
More informationANTI-CALC.
EN ANTI-CALC www.tefal.co.uk 6 7* 8 5 4 3 2 1 9 10 11 12 13 14 15 16 2 1 EN Depending on model * fig.1 fig.2 fig.3 fig.4 fig.5 fig.6 * fig.7 fig.8 fig.9 EN Depending on model * fig.10 fig.11 fig.12 fig.13
More informationTHERMflow Thermal Store Cylinders
THERMflow Thermal Store Cylinders Technical Manual Tel: (01592) 611123 www.mcdonaldwaterstorage.com September 2018 THERMflow Thermal Store Tank Technical Manual Manual must be completed by Installer and
More informationThe guarantee on this appliance is valid for 12 months from the first day of installation.
Users Manual Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This Users Manual provides detailed instructions and recommendations
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More information