USE. Steam dispensing. n 4 holes. How to access the programming function

Size: px
Start display at page:

Download "USE. Steam dispensing. n 4 holes. How to access the programming function"

Transcription

1 TURBOSTEAM SERIE M

2 USE Steam dispensing Machines equipped with the TURBOSTEAM (STOP STEAM) dispensing system have the "stop steam dispensing when set temperature is reached" function, and can rapidly heat and froth milk. After selecting the type of milk you desire (heated or frothed), insert the steam nozzle () into a suitable container, making sure the bulb is completely immersed in the milk. Turn the automatic steam knob () in the appropriate direction. Once the set temperature is reached, steam dispensing can be stopped automatically or manually, as described in the paragraph "Programming the automatic steam knob". The turbosteam steam wand has a nozzle with four holes with a diameter of.75 mm. On request, a nozzle with holes with a diameter of mm is available and is the best solution for beverages that are less than 350 g. The nozzle with mm holes can be identified by the groove "S". S n 4 holes ø,75mm n 4 holes ø mm Standard nozzle Optional nozzle How to access the programming function The machine s program is memorized on the CPU - DISPLAY cards. The machine is programmed with a standard program in the factory. To read and change the set data the programming function is accessed as follows: Touch the sensor with the technician s key. The autosteam function is available in versions with a CPU 3,000 memory or higher.. Day Hour The sound of the buzzer indicates recognition of the key and the word TECHNICIAN appears on the display. Scroll through the boxes on the panel until you see: Option Steam stop: xxx C You may now program the automatic steam function, by setting a xxx C temperature value for either hot or whipped milk.

3 Automatic steam knob programming The automatic steam knob () can be programmed in two ways: MODE, STEAM AUTOMATIC STOP Set a temperature value on item "Stop steam xxx C", by using keys "+" and "-". The range for "xx" is from 55 C minimum to 85 C maximum Steam dispensing is controlled by the knob (). In particular: - when the knob is turned to the left, the milk is heated. - When the knob is turned to the right, the milk is frothed. Once the knob has been turned (), it automatically returns to the "O" position. Q P When the drink to be heated exceeds +55 C, the message "Stop steam xxx C" appears on the display - this indicates the temperature read by the probe. N.B.: When the set temperature is reached, steam supply stops automatically and the display continues indicating steam value for the next 5 minutes. Steam supply can be interrupted at any time (even if the set temperature was not reached), by again turning the automatic steam knob () in the same direction used for activating supply. MODE 2, STEAM MANUAL STOP Set the temperature value on item "Stop steam xxx C" at "000" zero. Steam dispensing and the choice of milk type are performed as in MODE Hot milk Frothed milk Turn the knob () and the message "Stop steam xxx C" immediately appears on the display, indicating the temperature read by the probe. Note: The user controls when steam dispensing is stopped. When the desired temperature is reached, the user will turn the automatic steam knob () in the same direction used to start the steam dispensing process. For the next 5" after steam dispensing has stopped, the display shows the milk temperature that has been reached. Time out is set at 80" for both the programming modes. A If, when the machine is powered up, the probe does not detect any temperature value (thermo-couple not operating), the STOP STEAM function is disabled and "----" is shown in the setting square instead of "xx C". The latest set temperature value is, however, saved until thermo-couple operation is restored. The machine works as if the STOP STEAM function does not exist. Frothed milk and hot milk are available, but the temperature read by the probe will not appear on the display. The ideal setting for milk frothing is set in the factory. If additional adjustments must be made, turn the flow adjustment valve (A) underneath the cup heating shelf on the right side of the machine: - counterclockwise: more air > more frothy milk - clockwise: less air > less frothy milk Note: even slight turns of the valve (A) can make a great difference in how the milk is frothed. Machines without display In machines without a display, the STOP STEAM function can only occur according to the procedure described in mode. The difference is that the temperature is set in the factory with the standard setting of 72 C (6 F), and is not set by the user. You must perform these preliminary operations to read or change set data: - Switch off the machine and set the DIP switch to ON, on the CPU card. - Connect the display card (cod , with version memory or successive) the programming keypad (cod ) the Flat cable (cod ) to the Y3 connecter of the AS Turbosteam card. - Switch on the machine, enter the programming phase using the special keypad and scroll through the display screens until the STOP STEAM function appears. - Change the setting so that it falls within the range of C (3 85 F). Once the best setting is chosen, exit the programming phase. Switch off the machine. Disconnect the display card, programming keypad, and Flat cable from the Y3 connector of the AS Turbosteam card. Set the DIP switch to OFF on the CPU card, then switch on the machine.

4 Schema elettrico - Wiring diagram - Schéma éléctrique - Elektrischer Schaltplan - Esquema electrico - Esquéma electrico

5 Il Costruttore si riserva il diritto di modificare senza preavviso le caratteristiche delle apparecchiature presentate in questa pubblicazione Le Fabricant se réserve le droit de modifier sans préavis les caractéristiques des appareils présentés dans cette publication The Manufacturer reserves the right to modify the appliances presented in this publication without notice Der Hersteller behält sich das Recht vor, die in dieser Broschüre vorgelegten Geräte ohne Voranzeige zu ändern El Constructor se reserva el derecho de modificar sin preaviso las caracteristicas de las maquinas tratadas en este manual O Constructor reserva-se o direito de modificar sem aviso previo as máquinas tratadas neste manual (rev. 03/04)

Type Sup 037RG. Errata: Descaling. These instructions replace those reported in the manual.

Type Sup 037RG. Errata: Descaling. These instructions replace those reported in the manual. Type Sup 037RG Errata: Descaling These instructions replace those reported in the manual. Steady on DESCALING Limescale normally builds up with the use of the appliance. The machine must be descaled when

More information

NL Installatievoorschriften p. 3. FR Instructions d installation p. 5. DE Montageanleitung p. 7. EN Operating and installation Instructions p.

NL Installatievoorschriften p. 3. FR Instructions d installation p. 5. DE Montageanleitung p. 7. EN Operating and installation Instructions p. NL Installatievoorschriften p. 3 FR Instructions d installation p. 5 DE Montageanleitung p. 7 EN Operating and installation Instructions p. 9 780/1-786/1-787 1 2 3 4 5 2 GENERAL INFORMATION General These

More information

HALO ELITE BIVVY LIGHT

HALO ELITE BIVVY LIGHT UK HALO ELITE BIVVY LIGHT FEATURES: Illuminates on a take, when used with up to four radio-equipped bite alarms (EOS-R, RS series, PSR and TXR+ remote system), positioned up to 50 metres away. Can also

More information

CVEN x 1/1 GN 6-12 x 20 DEVICE FOR GASTRONOMY

CVEN x 1/1 GN 6-12 x 20 DEVICE FOR GASTRONOMY DEVICE FOR GASTRONOMY CVEN061 One Touch Automatically and with only a single touch, you can access the ideal and most efficient cooking for each dish, due to the exclusive present and widely tested methods,

More information

05/2014. Mod: E99/PLA2-N. Production code: BEFT908L

05/2014. Mod: E99/PLA2-N. Production code: BEFT908L 05/2014 Mod: E99/PLA2-N Production code: BEFT908L BEFT908L E99/PLA2-N CATALOGO PARTI DI RICAMBIO CATALOGUE PIECES DETACHEES ERSATZTEILKATALOG SPARE PARTS CATALOGUE GAS ELETTRICO TOP CON ARMADIO GAZ ELECTRIQUE

More information

Centrifugal electric pumps ATEX safety instructions

Centrifugal electric pumps ATEX safety instructions Centrifugal electric pumps ATEX safety instructions CONTENTS Page 1. Foreword..................... 8 2. Technical Data................ 9 3. Installation Instructions:....... 10 - General Information -

More information

Elettropompe centrifughe Centrifugal electric pumps Electropompes centrifuges Fliehkraftpumpen Electrobombas centrífugas

Elettropompe centrifughe Centrifugal electric pumps Electropompes centrifuges Fliehkraftpumpen Electrobombas centrífugas Elettropompe centrifughe Centrifugal electric pumps Electropompes centrifuges Fliehkraftpumpen Electrobombas centrífugas II 2G, II 2GD c IIB, IIC Ex d, Ex de Ex td istruzioni di sicurezza safety instructions

More information

Technical instructions

Technical instructions FILTER REPLACEMENT 1 ATTENTION: the replacement and insertion of the filter must be effectuated with the machine turned off. 1. REMOVE THE WATER TANK FROM THE MACHINE 2. FILL THE WATER TANK TO THE MAXIMUM

More information

ADDITIONAL FLUE GAS DRAUGHT FAN ATTACK PV150 INSTRUCTIONS FOR USE

ADDITIONAL FLUE GAS DRAUGHT FAN ATTACK PV150 INSTRUCTIONS FOR USE ADDITIONAL FLUE GAS DRAUGHT FAN ATTACK PV150 INSTRUCTIONS FOR USE W W W. A T T A C K. S K INTRODUCTION Dear customer, thank you for your trust and purchase of our product Additional flue gas draught fan.

More information

THERMAL RADIATORS INSTALLATION INSTRUCTIONS AND USER GUIDE RF3P RF4P RF5P RF6P RF8P RF10P RF12P RF14P RF3E RF4E RF5E RF6E RF8E RF10E RF12E RF14E

THERMAL RADIATORS INSTALLATION INSTRUCTIONS AND USER GUIDE RF3P RF4P RF5P RF6P RF8P RF10P RF12P RF14P RF3E RF4E RF5E RF6E RF8E RF10E RF12E RF14E INSTALLATION INSTRUCTIONS AND USER GUIDE RF THERMAL RADIATORS RF3P RF4P RF5P RF6P RF8P RF10P RF12P RF14P RF3F RF4F RF5F RF6F RF8F RF10F RF12F RF14F RF3E RF4E RF5E RF6E RF8E RF10E RF12E RF14E Please read

More information

SAITEK srl. Serie. < Automatic burner control unit > Casalgrande (RE) ITALY Tel Fax

SAITEK srl. Serie. < Automatic burner control unit > Casalgrande (RE) ITALY Tel Fax Serie < Automatic burner control unit > MONO DOUBLE ELECTRODE FLAME DETECTION SAITEK srl www.saitek.it info@saitek.it Casalgrande (RE) ITALY Tel. +39 0522 848211 Fax +39 0522 849070 NOTE. AUTOMATIC BURNER

More information

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS A it KIT UNITÀ AMBIENTE E INTERFACCIA A LED PER IL CONTROLLO DELLA TEMPERATURA AMBIENTE DEL LOCALE en KIT ROOM UNIT AND LED INTERFACE ROOM TEMPERATURE CONTROL ACCESSORY de RAUMGERÄT UND LED-SCHNITTSTELLE

More information

104G / 204G / 304G Catalogue of Replacement Parts Catalogue de Pieces de Rechange Ersatzteilkatalog

104G / 204G / 304G Catalogue of Replacement Parts Catalogue de Pieces de Rechange Ersatzteilkatalog / / Catalogue of Replacement Parts Catalogue de Pieces de Rechange Ersatzteilkatalog CONTENTS SOMMAIRE INHALT Schematic 2 Schema Übersicht Housing Components 3 Éléments D Habillage Gehäuseteile Door Components

More information

INSTRUCTION MANUAL VARIABLE TEMPERATURE KETTLE MANUEL D UTILISATION BOULLOIRE À TEMPÉRATURE VARIABLE MANUAL DE USO HERVIDOR DE TEMPERATURA VARIABLE

INSTRUCTION MANUAL VARIABLE TEMPERATURE KETTLE MANUEL D UTILISATION BOULLOIRE À TEMPÉRATURE VARIABLE MANUAL DE USO HERVIDOR DE TEMPERATURA VARIABLE INSTRUCTION MANUAL VARIABLE TEMPERATURE KETTLE MANUEL D UTILISATION BOULLOIRE À TEMPÉRATURE VARIABLE MANUAL DE USO HERVIDOR DE TEMPERATURA VARIABLE EN EL SV PT ES NL DE FR ES EN FR Dear Customer, Thank

More information

IMESA: A LIFE BY YOUR SIDE

IMESA: A LIFE BY YOUR SIDE EASY WASH IMESA: A LIFE BY YOUR SIDE IMESA is a leading Italian company in the production of laundry equipment. We achieved this goal thanks to more than 40 years of total commitment to the continuing

More information

ATTACK DPX USER MANUAL. for correct installation, operation and cleaning WOOD GASIFYING BOILER STANDARD / PROFI / LAMBDA

ATTACK DPX USER MANUAL. for correct installation, operation and cleaning WOOD GASIFYING BOILER STANDARD / PROFI / LAMBDA WOOD GASIFYING BOILER ATTACK DPX STANDARD / PROFI / LAMBDA USER MANUAL for correct installation, operation and cleaning W W W. A T T A C K. S K Important! Read this manual properly before the boiler start-up!

More information

Sirène flash. Sirena con lampeggiante DP8406 DP8407 DP8408. Alarmsirene mit Blitzlampe. Siren and flashing. p. 19

Sirène flash. Sirena con lampeggiante DP8406 DP8407 DP8408. Alarmsirene mit Blitzlampe. Siren and flashing. p. 19 Sirène flash DP80 DP80 DP808 Sirena con lampeggiante Alarmsirene mit Blitzlampe Siren and flashing p. 9 Operation As a supplement to the control panel s integrated siren, the external alarm siren alerts

More information

MLC 30. Bruksanvisning Brugsanvisning Bruksanvisning Käyttöohjeet Instruction manual Betriebsanweisung

MLC 30. Bruksanvisning Brugsanvisning Bruksanvisning Käyttöohjeet Instruction manual Betriebsanweisung MLC 30 101103105107109111102021110025108024042106023061104022041100020040060001 Bruksanvisning Brugsanvisning Bruksanvisning Käyttöohjeet Instruction manual Betriebsanweisung Manuel d instructions Gebruiksaanwijzing

More information

Heliox UV. Model Heliox LP P Heliox LP P Heliox LP P300

Heliox UV. Model Heliox LP P Heliox LP P Heliox LP P300 EN FR ES IT DE PT UV TREATMENT SYSTEM SYSTÈME DE TRAITEMENT UV SISTEMA DE TRATAMIENTO UV SISTEMA DI TRATTAMENTO UV UV-BEHANDLUNG-SYSTEM SISTEMA DE TRATAMENTO UV Heliox UV EN PE Model. 63135 Heliox LP P95

More information

TECHNICAL INFORMATION CVA 4062/CVA 4066/CVA 4068 Coffee Systems SERVICE MODE Miele USA

TECHNICAL INFORMATION CVA 4062/CVA 4066/CVA 4068 Coffee Systems SERVICE MODE Miele USA TECHNICAL INFORMATION CVA 462/CVA 466/CVA 468 Coffee Systems SERVICE MODE 29 Miele USA CVA 462/CVA 466/CVA 468 Coffee Systems 4.3 Service Mode Initial requirements: Switch the appliance off. Accessing:.

More information

OC Series - Automatic coffee machines. OLC1 Lucia High performance liquid coffee dispenser. Users Handbook - 1 -

OC Series - Automatic coffee machines. OLC1 Lucia High performance liquid coffee dispenser. Users Handbook - 1 - OLC1 Lucia High performance liquid coffee dispenser Users Handbook - 1 - Every effort has been made to ensure that the information contained in this manual is up to date and correct. However, the author,

More information

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS CONTENTS 1. Transportation Positioning Installation 3 2. Starting up 3 3. Safety instructions 4 4. Temperature regulation

More information

M2Z M NOTICE D INSTALLATION INSTALLATION INSTRUCTION MANUALE D INSTALLAZIONE MANUAL DE INSTALACIÓN AUFSTELLUNGS- HANDBUCH INSTRUÇÕES DE INSTALAÇÃO

M2Z M NOTICE D INSTALLATION INSTALLATION INSTRUCTION MANUALE D INSTALLAZIONE MANUAL DE INSTALACIÓN AUFSTELLUNGS- HANDBUCH INSTRUÇÕES DE INSTALAÇÃO (Etiquette signalétique) NOTICE D INSTALLATION INSTALLATION INSTRUCTION MANUALE D INSTALLAZIONE MANUAL DE INSTALACIÓN AUFSTELLUNGS- HANDBUCH INSTRUÇÕES DE INSTALAÇÃO F I E D P M2Z M MODULE 2 ZONES MIXTE

More information

ISTRUZIONI D USO PER L UTENTE OPERATING AND MAINTENANCE MANUAL MODE D EMPLOI ET D ENTRETIEN BEDIENUNGS UND WARTUNGSANLEITUNG

ISTRUZIONI D USO PER L UTENTE OPERATING AND MAINTENANCE MANUAL MODE D EMPLOI ET D ENTRETIEN BEDIENUNGS UND WARTUNGSANLEITUNG Abbattitore 14 Teglie Blast chiller Refroidisseur rapide Schockfroster ISTRUZIONI D USO PER L UTENTE OPERATING AND MAINTENANCE MANUAL MODE D EMPLOI ET D ENTRETIEN BEDIENUNGS UND WARTUNGSANLEITUNG Descrizione

More information

WINDSHEAR STORM and WINDSHEAR STORM DELUXE MODEL NO: 98778/98780

WINDSHEAR STORM and WINDSHEAR STORM DELUXE MODEL NO: 98778/98780 TORNADO INDUSTRIES, LLC 333 CHARLES COURT WEST CHICAGO, IL 60185 (630)-818-1300 FAX (630)-818-1301 WWW.TORNADOVAC.COM Operations & Maintenance Manual For Commercial Use Only WINDSHEAR STORM and WINDSHEAR

More information

STEAM TILTING KETTLES

STEAM TILTING KETTLES INSTRUCTION MANUAL FOR INSTALLATION, MAINTENANCE STEAM TILTING KETTLES BASKET PRIV MANUALE D ISTRUZIONE Codice PRIV Nr. Revis. Data di revisione Punto Natura della correzione Storia delle revisioni 04

More information

SIRIO Contatore di energia Energy meter

SIRIO Contatore di energia Energy meter SIRIO Contatore di energia Energy meter ATTENZIONE - La Elcontrol Energy Net S.p.a. declina ogni responsabilità per eventuali danni a persone o cose originati da un uso improprio o da errato impiego dei

More information

Raffaello From serial number Group

Raffaello From serial number Group Group 1 C199900260 Solenoid valve V.230/50-60 1 C199900261 Solenoid valve, V. 115/60 2 C449900786 O-Ring 3 C229900553 Nut 4 C449900079 O-Ring 5 C619900554 Metal filter 6 C229900549 Gigleur 7 C229900674

More information

Air-cooled heat pump USER MANUAL HBI IHBIFY _01

Air-cooled heat pump USER MANUAL HBI IHBIFY _01 Air-cooled heat pump USER MANUAL HBI GB IHBIFY. 0-625230_0 Index HBI control panel... 6 Control panel display... 7 HBI functioning mode... 9 COOLING Mode:... 9 HEATING Mode:... 9 DOMESTIC HOT WATER PRODUCTION

More information

The future is in the air

The future is in the air The future is in the air ecological air conditioners Dianclima is looking forward to the third generation ; that one of our sons, eager for clean air, and aware of respect for nature and world health,

More information

BSR Addressable Fire Detection control panel. Installation operation manual

BSR Addressable Fire Detection control panel. Installation operation manual BSR-1116 Addressable Fire Detection control panel Installation operation manual ATTENTION!!! READ THE MANUAL BEFORE THE INSTALLATION AND PAY ATTENTION TO PARAGRAPH 2.6.3 AND 2.6.4. Page 2 from 36 Contents

More information

THIS INSTRUCTION BOOK MAY CONTAIN ERRORS AND OMISSIONS. DESIGN AND SPECIFICATION ARE SUBJECT TO CHANGE WITHOUT NOTICE.

THIS INSTRUCTION BOOK MAY CONTAIN ERRORS AND OMISSIONS. DESIGN AND SPECIFICATION ARE SUBJECT TO CHANGE WITHOUT NOTICE. THIS INSTRUCTION BOOK MAY CONTAIN ERRORS AND OMISSIONS. DESIGN AND SPECIFICATION ARE SUBJECT TO CHANGE WITHOUT NOTICE. ESTE MANUAL DE INSTRUCCIONES PUEDE CONTENER ERRORES Y OMISIONES. EL DISEÑO Y LAS ESPECIFICACIONES

More information

Strand Lighting Inc Darin Way, Cypress, CA 90630, USA Tel: Fax:

Strand Lighting Inc Darin Way, Cypress, CA 90630, USA Tel: Fax: Strand Lighting Inc. 6603 Darin Way, Cypress, CA 90630, USA Tel: +1-714-230-8200 Fax: +1-714-230-8173 Strand Lighting Europe Ltd. Unit 2, Royce Road, Fleming Way, Crawley, West Sussex. United Kingdom Tel:

More information

Thermo CTP-E45T 0 Pot

Thermo CTP-E45T 0 Pot Thermo Pot 0 CTP-E45T GENERAL SAFETY PRECAUTIONS 1. Read the Instruction Manual carefully before using for the first time. 2. Always switch off and unplug the appliance from the power supply BEFORE cleaning

More information

USING AND MAINTENANCE MANUAL FOR SELF-CONTAINED POWER BRUSH MACHINE FOR CARPET AND HARD FLOOR. Elite-Silent. Elite-Silent

USING AND MAINTENANCE MANUAL FOR SELF-CONTAINED POWER BRUSH MACHINE FOR CARPET AND HARD FLOOR. Elite-Silent. Elite-Silent USING AND MAINTENANCE MANUAL FOR SELF-CONTAINED POWER BRUSH MACHINE FOR CARPET AND HARD FLOOR Elite-Silent Elite-Silent READ CAREFULLY BEFORE USING THE MACHINE Version 08/02 Generalities The body of the

More information

DESCALING INSTRUCTIONS for: CS220, CS200, CS100 Page 3 Cappucinatore CS20 Page 5 Gemini CS223 Page 6 Zenius ZN100 Page 7

DESCALING INSTRUCTIONS for: CS220, CS200, CS100 Page 3 Cappucinatore CS20 Page 5 Gemini CS223 Page 6 Zenius ZN100 Page 7 Australia & New Zealand DESCALING INSTRUCTIONS for: CS220, CS200, CS100 Page 3 Cappucinatore CS20 Page 5 Gemini CS223 Page 6 Zenius ZN100 Page 7 Call us on AU 1800 182 206 or NZ 0800 466 060 (24/7) if

More information

Mini MP 170 V.V. Mini MP 220 V.V. Mini MP 170 Combi. Mini MP 220 Combi

Mini MP 170 V.V. Mini MP 220 V.V. Mini MP 170 Combi. Mini MP 220 Combi Mini MP 170 V.V. Mini MP 220 V.V. Mini MP 170 Combi Mini MP 220 Combi P.O. Box 16625, Jackson, MS 39236-6625 264 South Perkins St., Ridgeland, MS 39157 e-mail: robocoup@misnet.com - website: www.robotcoupeusa.com

More information

INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE

INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE SYSTEM CONCEPT When not transferring fuel, the pressure in the underground piping system for gasoline distribution may fall due to

More information

TILTING KETTLES WITH MIXER BASKETT

TILTING KETTLES WITH MIXER BASKETT OWNER S INSTRUCTION MANUAL TILTING KETTLES WITH MIXER BASKETT Models PRIG M PRIE M PRIV M Cat II 2H3+ - 0085 AU0137 MANUALE D USO Codice PRIE-IG-IV /M Storia delle revisioni Nr Revis Data di revisione

More information

Blixer 4 P.O. Box 16625, Jackson, MS

Blixer 4 P.O. Box 16625, Jackson, MS P.O. Box 16625, Jackson, MS 39236-6625 280 South Perkins St., Ridgeland, MS 39157 e-mail: robocoup@misnet.com - website: www.robotcoupeusa.com - Phone : 1-800-824-1646 Blixer 4 IMPORTANT WARNING WARNING

More information

DESCALING INSTRUCTIONS For Professional/Out-of-Home Machines:

DESCALING INSTRUCTIONS For Professional/Out-of-Home Machines: Australia & New Zealand DESCALING INSTRUCTIONS For Professional/Out-of-Home Machines: Gemini, Cappuccinatore and Zenius Call us on AU 1800 182 206 or NZ 0800 466 060 (24/7) if you have any questions pg.

More information

Compact wall hung boiler. Micro processor Brass Hydraulic set

Compact wall hung boiler. Micro processor Brass Hydraulic set Compact wall hung boiler Micro processor Brass Hydraulic set A compact boiler of quality The Range Natural Draught Forced draught Pocket 24 N Natural draught Open chamber Combined Instantaneous Pocket

More information

Ηλεκτρικές επιτραπέζιες εστίες 41

Ηλεκτρικές επιτραπέζιες εστίες 41 www.severin.com DE GB FR NL ES IT DK SE FI PL GR RU Gebrauchsanweisung Kochplatten 4 Instructions for use Electric table-top hot-plates 8 Mode d emploi Plaques chauffantes électriques 12 Gebruiksaanwijzing

More information

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE Technical features Guide to LCD symbols Guide to keys Technical features Supply by communication bus Number of temperature levels 2 (DAY / NIGHT) Temperature

More information

DESCALING INSTRUCTIONS For Professional Machines:

DESCALING INSTRUCTIONS For Professional Machines: Business Solutions Australia & New Zealand DESCALING INSTRUCTIONS For Professional Machines: Gemini, Cappuccinatore and Zenius An expert is available to help you 24/7 on AU 1800 182 206 or NZ 0800 466

More information

DC200 Digital Dispenser Operating Manual

DC200 Digital Dispenser Operating Manual DC200 Digital Dispenser Operating Manual 2015 Fisnar Phone: (973) 646-5044 E-mail: info@fisnar.com Table of Contents Product Safety Statements 4 Specifications 6 Accessories 6 External Controls 7 Machine

More information

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E VANTAGE Installation Manual Release Date: April 16, 2003 Publication Number: 3120031005INS Revision Date: January 22, 2015 Revision: E Visit the Cornelius web site at www.cornelius.com for all your Literature

More information

Rev D 3/20/17

Rev D 3/20/17 Rev D 3/20/17 Installation and Operating Instructions ADAEZ Wireless Interface Module (WIM) Note Changes or modifications not expressly approved by the party responsible for compliance could void the user

More information

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents - English... 1 Instruction Manual Analog, Dry Block Heater, 1 Block, HB1AL Analog, Dry Block Heater, 2 Block, HB2AL Analog, Dry Block Heater, 4 Block, HB4AL Analog, Dry Block Heater, 6 Block, HB6AL Digital,

More information

RADIO WAVE WEEKLY PROGRAMMABLE THERMOSTAT CH150RF

RADIO WAVE WEEKLY PROGRAMMABLE THERMOSTAT CH150RF RADIO WAVE WEEKLY PROGRAMMABLE THERMOSTAT CH150RF INDEX Introduction...3 Controls and indications...4 Controls...4 Indications...5 User manual...6 Setting the date and time...6 Summer/Winter selection...7

More information

INDICE. Installation recommendation

INDICE. Installation recommendation Technical manual INDICE 1 MAIN COMPONENT LIST Pag. 3 2 MOUNTING EXAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION EXAMPLES Pag. 6 4 OPTICS CONFIGURATION Pag. 7 TX Pag. 7 RX Pag. 8 5 SANDOR WS

More information

TAURA 24 MC W TOP AZIENDA CERTIFICATA ISO 9001

TAURA 24 MC W TOP AZIENDA CERTIFICATA ISO 9001 AZIENDA CERTIFICATA ISO 9001 CALDAIA MURALE A GAS PER SANITARIO E RISCALDAMENTO WALL-MOUNTING GAS BOILER FOR HOT WATER AND HEATING CHAUDIÈRE MURALE À GAZ POUR LA PRODUCTION D EAU CHAUDE SANITAIRE ET LE

More information

FLAVIA CREATION C500 User Guide

FLAVIA CREATION C500 User Guide FLAVIA CREATION C500 User Guide www.marsdrinks.com CONTENTS Page Safety & Installation Guidelines... 1-2 Brewer Layout... 3 Setting up your Brewer... 4-5 Selecting Cups to Use... 6 The FLAVIA CREATION

More information

LB 4712 MAINTENANCE MANUAL FOR TECHNICAL ASSISTANCE

LB 4712 MAINTENANCE MANUAL FOR TECHNICAL ASSISTANCE LB 4712 MAINTENANCE MANUAL FOR TECHNICAL ASSISTANCE Manual code 10066846 / Rel. 0.00 / MaRch 2012 LB 4712 Machine code 10080586 Manual code 10066846 Rel. 0.00 edition 03/2012 copyright lavazza S.p.a. Tel.

More information

ADL DYNAMIC STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE ADL 2012 ADL 3018 ADL 4024 ADL 5030

ADL DYNAMIC STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE ADL 2012 ADL 3018 ADL 4024 ADL 5030 INSTALLATION INSTRUCTIONS AND USER GUIDE ADL DYNAMIC STORAGE HEATERS ADL 2012 ADL 3018 ADL 4024 ADL 5030 Please read these instructions CAREFULLY before installing or using this appliance for the first

More information

Millo / Millo pro. Nr x000 / 1805-x000

Millo / Millo pro. Nr x000 / 1805-x000 Millo / Millo pro Nr. 1804-x000 / 1805-x000 Renfert GmbH Industriegebiet 78247 Hilzingen / Germany Tel. +49 7731 8208-0 Fax +49 7731 8208-70 info@renfert.com www.renfert.com Made in Germany 0208 21-6543

More information

Electric table-top hot-plates

Electric table-top hot-plates Gebrauchsanweisung Instructions for use Mode d emploi Gebruiksaanwijzing Instrucciones de uso Manuale d uso Brugsanvisning Bruksanvisning Käyttöohje Instrukcja obsługi Oδηγίες χρήσεως Руководство по эксплуатации

More information

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Modular Standard HP Chiller 1/4 screw compressor with Carel driver Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?

More information

ULTRASONIC HUMIDIFIER

ULTRASONIC HUMIDIFIER ULTRASONIC HUMIDIFIER USER, INSTALLATION AND MAINTENANCE GUIDE Rev 12.02-EN 2 1 Package content... 3 2 Security measures... 3 3 Conformity... 4 4 Working principle... 5 5 Characteristics... 5 6 Installation...

More information

Cedarbrook Sauna + Steam Family owned and operated since 1971

Cedarbrook Sauna + Steam Family owned and operated since 1971 Cedarbrook Sauna + Steam Family owned and operated since 1971 We build cedar saunas, kits, sauna doors, accessories for commercial saunas & residential sauna rooms AND we have the expertise to fit you

More information

Thermostatic Heads TT3000 TT3000C TT /02/2018. Technical Data Sheet

Thermostatic Heads TT3000 TT3000C TT /02/2018. Technical Data Sheet Technical Data Sheet Thermostatic Heads TT3000 TT3000C TT3002 15/02/2018 Function Thermostatic valves allow to make each room independent with a specific set temperature, thus enhancing comfort and actual

More information

INSTRUCTION MANUAL STAND MIXER MANUEL D UTILISATION BATTEUR SUR SOCLE MANUAL DE USO BATIDORA DE PIE EN FR FR ES

INSTRUCTION MANUAL STAND MIXER MANUEL D UTILISATION BATTEUR SUR SOCLE MANUAL DE USO BATIDORA DE PIE EN FR FR ES INSTRUCTION MANUAL STAND MIXER MANUEL D UTILISATION BATTEUR SUR SOCLE MANUAL DE USO BATIDORA DE PIE EN EN FR FR ES Dear Customer, Thank you very much for purchasing a Smeg 50 s Style stand mixer. By choosing

More information

T14 AS1 T20 T40 T24. ISO 9001 Cert. N 0412/2 SERVICE MANUAL. Cod /0-03/ Rev. 000

T14 AS1 T20 T40 T24. ISO 9001 Cert. N 0412/2 SERVICE MANUAL. Cod /0-03/ Rev. 000 B L A S T C H I L L E R S T4 MT AS T T24 T4 T2 ISO 9 Cert. N 42/2 SERVICE MANUAL Cod. 736/ - 3/24 - Rev. WARNING!!! THE FOLLOWING OPERATIONS AND THOSE HIGHLIGHTED BY THIS SYMBOL MUST NOT BE PERFORMED BY

More information

Controllers for refrigeration EVBOX1

Controllers for refrigeration EVBOX1 Controllers for refrigeration EVBOX1 TheInnovationEvolution EVBOX1 Electrical controllers for single-phase cold rooms Quadri elettrici fronte cella per celle frigorifere monofase 3 Controllers for refrigeration

More information

Carmen. Operating Instructions. 1

Carmen. Operating Instructions.  1 Carmen Operating Instructions Streamline Supplies 9 Joseph Baldwin Place, Shepparton Victoria Ph: Fax: www.streamlinesupplies.com.au Introduction Please read this technical handbook carefully since it

More information

OilMatic Pro / 230 V AC

OilMatic Pro / 230 V AC Instructions manual OilMatic Pro / 230 V AC Alarm system for oil-water separators OilMatic Pro 22-01-2017 Manufacturer: Bamo 1 Description...3 2 Mounting and start-up...4 3 Wiring...5 4 Startup - tests...7

More information

gebruiksaanwijzing user manual betriebsanleitung mode d'emploi

gebruiksaanwijzing user manual betriebsanleitung mode d'emploi gebruiksaanwijzing user manual betriebsanleitung mode d'emploi Nederlands... 3 NL English... 7 GB Deutsch... 11 D Français... 15 F Español... 19 ES Dit apparaat voldoet aan de volgende EEG-richtlijnen:

More information

CONTENTS Introduction Information Services Getting Started Phone Directory Messages Optional Features Alerts Other Features

CONTENTS Introduction Information Services Getting Started Phone Directory Messages Optional Features Alerts Other Features A USER S GUIDE TM Introduction Introduction...1 Controls...2 Getting Started Turning the Pager On/Off...3 Backlight...4 Setting the Time and Date...5 Messages Types of Messages...6 Choosing the Scroll

More information

15x15 Diamantato White Lux 7,5x15 Diamantato White Lux 5x15 Cornice Liberty White Lux 2x15 Bullnose White Lux 11x15 Battiscopa 900 White Lux

15x15 Diamantato White Lux 7,5x15 Diamantato White Lux 5x15 Cornice Liberty White Lux 2x15 Bullnose White Lux 11x15 Battiscopa 900 White Lux References Book 2 >2 15x15 Diamantato White Lux 7,5x15 Diamantato White Lux 5x15 Cornice Liberty White Lux 2x15 Bullnose White Lux 11x15 Battiscopa 900 White Lux 3< >4 15x15 Diamantato Ivory Lux 15x15

More information

SERIES PSCII GAS BOILERS

SERIES PSCII GAS BOILERS USER S INFORMATION MANUAL SERIES PSCII GAS BOILERS TO THE INSTALLER:This manual is the property of the owner and must be affixed near the boiler for future reference. TO THE OWNER: This boiler should be

More information

K 60 D 070 Z KIT RÉGULATION SYSTÈME POUR POMPE À CHALEUR INVERTER AVEC CHAUFFAGE D APPOINT ÉLECTRIQUE

K 60 D 070 Z KIT RÉGULATION SYSTÈME POUR POMPE À CHALEUR INVERTER AVEC CHAUFFAGE D APPOINT ÉLECTRIQUE (tiquette signalétique) NOTIC INSTALLATION INSTALLATION INSTRUCTION MANUAL INSTALLAZION MANUAL INSTALACIÓN AUFSTLLUNGS- HANUCH INSTRUÇÕS INSTALAÇÃO F I P K 60 070 Z KIT RÉGULATION SYSTÈM POUR POMP À CHALUR

More information

MacDonald Steel Limited

MacDonald Steel Limited DELUXE FILLER / CROWNER MODEL - DFC4 1 REV 00 CAUTION / WARNING READ MANUAL BEFORE OPERATING MACHINE DO NOT EXCEED 50 PSI ON Co2 OR BEER LINES DO NOT EXCEED 100 F (35 C) ON Co2 OR BEER LINES DO NOT HOSE

More information

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V 05/06/2018 DESCRIPTION Autodialer to be fitted behind the cop or on top of the car / retrofit. A Connector for Esse-ti power supply (12 Vdc) B Micro SD Card

More information

MOD COD REV. 0 del 30/07/2013

MOD COD REV. 0 del 30/07/2013 MOD. 6431 COD. 2105100200 REV. 0 del 30/07/2013 De Longhi Appliances Srl Divisione Commerciale Ariete Via San Quirico, 300 50013 Campi Bisenzio (FI) - Italy E-Mail: info@ariete.net Internet: www.ariete.net

More information

USE AND MAINTENANCE MANUAL

USE AND MAINTENANCE MANUAL USE AND MAINTENANCE MANUAL SUPER MINI WARNING The manufacturer has the right to modify this manual without being obliged to update the previous editions.. IDENTIFICATION PLATE DALLA CORTE S.r.l Via Broglio,

More information

Controllers for refrigeration EVBOX1 data-logging extension

Controllers for refrigeration EVBOX1 data-logging extension Controllers for refrigeration EVBOX1 data-logging extension TheInnovationEvolution EVBOX1 data-logging extension Electrical controllers for single-phase cold rooms with data-logging extension for compliance

More information

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat Document No. 155-069P25 TH 193-5 Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat 50 60 70 80 TH0356R1 70 60 80 POWERS Description Features The TH 193 HC Hesitation Thermostats are

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL temperature / static pressure DIFF Opn Clo ALARM HI F2 DELAY ALARM LO OPEN DELAY CLOSE ADJUST Varifan + CPS-1 CPS-1 Although the manufacturer has made every

More information

P.N Rev A ELECTRIC HOT WATER DISPENSER User Manual BVSTWD7915 Series MODEL

P.N Rev A ELECTRIC HOT WATER DISPENSER User Manual BVSTWD7915 Series MODEL User Manual MODEL ELECTRIC HOT WATER DISPENSER BVSTWD7915 Series www.oster.ca P.N. 166025 Rev A IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed

More information

benchtop collection Instructions for use and warranty details Capsule Coffee Machine Model No.: CMBT01N

benchtop collection Instructions for use and warranty details Capsule Coffee Machine Model No.: CMBT01N benchtop collection Instructions for use and warranty details Capsule Coffee Machine Model No.: CMBT01N Dear Customer, Thank you and congratulations for choosing Kleenmaid. Your new appliance has been

More information

manual modbar - steam system

manual modbar - steam system manual modbar - steam system Modbar Steam is a stand-alone steaming system for retail environments requiring powerful steam capacity in a modern, minimal aesthetics. Ideal for cafes looking to complete

More information

MWR-n. MWR 5n MWR 10n MWR 20n. gebruiksaanwijzing user manual betriebsanleitung mode d'emploi

MWR-n. MWR 5n MWR 10n MWR 20n. gebruiksaanwijzing user manual betriebsanleitung mode d'emploi MWR 5n MWR 10n MWR 20n gebruiksaanwijzing user manual betriebsanleitung mode d'emploi Nederlands... 1 English... 6 Deutsch... 11 Français... 16 NL GB D F Dit apparaat voldoet aan de EMC-richtlijn 89/336/EEG,

More information

Tarifa de repuestos. Spare parts price list. Rociadores Rain Showers

Tarifa de repuestos. Spare parts price list. Rociadores Rain Showers 0 Tarifa de repuestos Spare parts price list Rociadores Rain Showers Índice Index Synchro... Seasons 0... 0 Seasons 00... Seasons D0... Seasons Nature... Moon... Eleo... Monsoon... Dinled Square 00...

More information

Professional Cleaning Machines Since 1968 EN Use and Maintenance

Professional Cleaning Machines Since 1968 EN Use and Maintenance EN Use and Maintenance 8050819 ed. 08-2017 1 Art. Mod. Cap.ty 2 3 4 Nr Vac Air flow mba l/s 8 7 6 5 2 1 2 3 4 IT Produttore Modello Articolo Capacità fusto EN Manufacturer Model Article Container capacity

More information

POWERS 24 / 28 / 34 KW

POWERS 24 / 28 / 34 KW STORAGE BOILERS SERIES MAXICOMFORT-TECH RKA / - RKA /20 POWERS 2 / 2 / KW HEATING TECHNOLOGY SINCE 1959... A WORLD OF PERFOMANCES AN ENDLESS AMOUNT OF DOMESTIC HOT WATER REGARDLESS THE SMALL CAPACITIES

More information

EVM/A 16 F 3~ 50Hz CAMICIA ESTERNA Outer casing DISCO P/TENUTA Casing cover

EVM/A 16 F 3~ 50Hz CAMICIA ESTERNA Outer casing DISCO P/TENUTA Casing cover EVM/A 16 F 3~ 50Hz Dwg n 01377 2F 3F 4F 5F 6F Data di creaz./ 3930000002A 3930000003A 3930000004A 3930000005A 3930000006A First release 005-1 STADIO ASPIRAZIONE Suction casing 241498234 May 2002 005-2

More information

IN NOURISHING SECURITY.

IN NOURISHING SECURITY. HOJA TÉCNICA 1400H171 Edición 02 (01 de 08) Electronic controllers for refrigeration R NEW leads the way Furthermore to control the CCPs Critical Control Points, in the HACCP Hazard Analysis Critical Control

More information

TOQUE BLANCHE GRANDE CARTE

TOQUE BLANCHE GRANDE CARTE REFRIGERATED BASES TOQUE BLANCHE GRANDE CARTE MAINTENANCE MANUAL MANUFACTURERS SPECIFICATION BONNET GRANDE CUISINE Rue des Frères Lumière - Z.I. Mitry Compans 77292 MITRY MORY cedex Tél. 01 60 93 70 00

More information

SPDT contacts: C/NO/NC. Contact Rating 16(4)A 250Vca. 7A1-1R306-00A A1-6R306-00A A A A A 10 90

SPDT contacts: C/NO/NC. Contact Rating 16(4)A 250Vca. 7A1-1R306-00A A1-6R306-00A A A A A 10 90 ENCASED THERMOSTATS Derived from the range of capillary control thermostats and limiters with liquid filled sensing element, they are the accurate, reliable and easily set-up devices for the regulation

More information

EGE Manisa 70 cm BIR Carinaro 55 cm. Fabriano June Presenter Francesco Nieli

EGE Manisa 70 cm BIR Carinaro 55 cm. Fabriano June Presenter Francesco Nieli EGE Manisa 70 cm BIR Carinaro 55 cm Fabriano June 2012 Presenter Francesco Nieli Keys and Interfaces Manisa EGE key Carnaro BIR key Tiny Full interface (SQG_CL_??) Tiny SD interface (SQG_CL_??) New LED

More information

INDEX. Installation recommendation

INDEX. Installation recommendation Technical manual INDEX 1 MAIN COMPONENTS Pag. 3 2 MOUNTING SAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION SAMPLES Pag. 6 4 WIRING Pag. 7 5 CONFIGURATION OF THE OPTICALS Pag. 8 OPTICAL TX Pag.

More information

IWECO Models IWCO9, IWMlO, IW7l0, IWLlO, IW8l0. IW509 IWCO9 IW609 IWMlO IW7l0 IW709 IWLlO IW8l0. Medium. Compact 65 litres 58 litres

IWECO Models IWCO9, IWMlO, IW7l0, IWLlO, IW8l0. IW509 IWCO9 IW609 IWMlO IW7l0 IW709 IWLlO IW8l0. Medium. Compact 65 litres 58 litres El IW Quick Reference Guide The Intuitive Washer can display the most recent user warning and fault The Intuitive Washer uses the motor to detect the fabric type The Intuitive Washer uses the same motor,

More information

REVOLUTION. Ice Shaver/Blender Operation Manual (2) Râpe-glace/mélangeur Manuel d utilisation (14)

REVOLUTION. Ice Shaver/Blender Operation Manual (2) Râpe-glace/mélangeur Manuel d utilisation (14) REVOLUTION GB FR ES PT IT DE NL DK SE NO GR RU TU BR CN JP KR SA Ice Shaver/Blender Operation Manual (2) Râpe-glace/mélangeur Manuel d utilisation (14) Granizadora de Hielo/Licuadora Manual de operación

More information

Introduction... 3 Setup & Suggestions... 4 Basic Use... 4 Setting Time... 4 Setting Temperature... 5 Setting Height / Pressure...

Introduction... 3 Setup & Suggestions... 4 Basic Use... 4 Setting Time... 4 Setting Temperature... 5 Setting Height / Pressure... Table of of Contents Contents... 2 Introduction... 3 Setup & Suggestions... 4 Basic Use... 4 Setting Time... 4 Setting Temperature... 5 Setting Height / Pressure... 6 Aligning the pedestal... 6 Guidelines

More information

Ovens 200 series. The ovens 200 series

Ovens 200 series. The ovens 200 series Ovens 200 series The ovens 200 series Checklist for appliance combinations 200 series 48 Ovens 200 series 50 Combi-steam ovens 200 series 54 Combi-microwave ovens 200 series 56 Microwave ovens 200 series

More information

CANADA BREBES980XL 120V 60Hz 1800W First Sale Date: US BES980XL 120V 60Hz 1800W First Sale Date:

CANADA BREBES980XL 120V 60Hz 1800W First Sale Date: US BES980XL 120V 60Hz 1800W First Sale Date: the Oracle Description: Colour: Electronic PID Temperature Control; Actively heated group head; Regulated extraction pressure; Low pressure pre-infusion; Dual pumps; Programmable shot temp; LCD interface;

More information

K-HA CENTRIFUGAL PRESSURE BOOSTING PUMPS. Technical Sheet

K-HA CENTRIFUGAL PRESSURE BOOSTING PUMPS. Technical Sheet K-HA Technical Sheet K-HA K-HA 40-22 K-HA 20-9 GENERAL DATA APPLICATIONS K-HA single impeller centrifugal pump is designed for water pressure boosting in households, flats (domestic properties) to provide

More information

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT HCT-1000 User Guide

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT HCT-1000 User Guide Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com HCT-1000 HCT-1000 User Guide INTRODUCTION The HCT-1000 is a hand-held convection rework tool. It features

More information

ECV SP GUE ALO CAT ICAL TECHN

ECV SP GUE ALO CAT ICAL TECHN TECHNICAL CATALOGUE ECV SP TAILOR MADE FOR UNITS FITTED WITH VRF SYSTEMS Models: 1001 1502 1602 2003 2303 10.16 Ref. 207609 Rev.105 CONTENT INTRODUCTION... 3 GENERAL DESCRIPTION... 3 CABINET... 3 HEAT

More information