Fan Coils & Air Handlers Product Catalog

Size: px
Start display at page:

Download "Fan Coils & Air Handlers Product Catalog"

Transcription

1 Fan Coils & Air Handlers Product Catalog

2 120V/240V motors PSC and ECM high efficiency constant torque motors Heavy-gauge, galvanized steel construction High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer Compatible with most brands of air conditioners or heat pumps. Easy slide-out blower and coil assembly for installation and service 100% factory leak and performance tested ETL Certified Ceiling Mount Cased and uncased options available Electric and hydronic heating Can be ordered with or without pump Cooling Capacity (Tons): 1.5, 2.0, 2.5, 3.0 Electric Heat (Kw): 0, 3, 5, 6, 8, 10 Hydronic Heat : Up to 51,000 BTUH HW heat Multi-Position & Wall Mount Electric and hydronic heat DX Cool Modular electric and hydronic heat kits (can be ordered separately) with or without pump. Multi-Position Cooling Capacity (Tons): Wall Mount Cooling Capacity (Tons): 1.5, 2.0, 2.5, 3.0 Electric Heat (Kw): 0, 3, 5, 6, 8, 10 Hydronic Heat: Up to 116,300 BTUH HW heat Ratings AirMark products are certified to meet the U.S. Department of Energy (DOE) requirements. Capacity and SEER values are calculated using the methodology in Section (M) of 10CFR Part 430. The calculation procedure utilizes test data collected in accordance with ANSI/AHRI 210/ and has been validated by an independent test in accordance with DOE standards.

3 To Place an Order 1. All orders MUST include the following information: ü ü ü ü Please address all AirMark orders to: APK Manufacturing LLC Unique quote reference number Account # & P.O.# Requested ship date If none, order will be placed and shipped ASAP ü COMPLETE model #, including Option Codes if standard, fill in the spaces with 000 ü ü Contact name, phone and MUST include all three. ANY notes regarding special pricing, terms, shipping etc. with supporting documentation. 2. Send Order To: orders: orderentry@airmark-ac.com Fax orders: (281) * *Alternate Fax (281) is available if difficulties are encountered with primary Fax number. If faxing an order, it is customer s responsibility to confirm order placement. orders are encouraged and preferred. Phone orders not accepted. To Obtain a Quote Call Your Local Sales Representative APK Manufacturing LLC 373 Atascocita Road Humble, TX

4 NOMENCLATURE 4 MULTI-POSITION 5 GAM SERIES (PSC, ELECTRIC)...5 GBM SERIES (PSC, HYDRONIC)...9 GEM SERIES (X13, ELECTRIC) GFM SERIES (X13, HYDRONIC) WALL MOUNT 20 GAW SERIES (PSC, ELECTRIC) GBW SERIES (PSC, HYDRONIC) GEW SERIES (X13, ELECTRIC) GFW SERIES (X13, HYDRONIC) CEILING MOUNT 36 GAS SERIES (PSC, ELECTRIC, UNCASED)...36 GAT SERIES (PSC, ELECTRIC, CASED)...40 GBS SERIES (PSC, HYDRONIC, UNCASED)...44 GBT SERIES (PSC, HYDRONIC, CASED)...47 GES SERIES (X13, ELECTRIC, UNCASED)...50 GET SERIES (X13, ELECTRIC, CASED)...54 GFS GFT SERIES (X13, HYDRONIC, UNCASED)...58 SERIES (X13, HYDRONIC, CASED)...61 Copyright 2017 APK Manufacturing. All rights reserved. ARMK1-1117

5 NOMENCLATURE G Series Air Handler Nomenclature G A M 18 G -000 AirMark Air Handler Voltage A = 240V PSC Motor B = 120V PSC Motor E = 240V Constant Torque EC Motor F = 120V Constant Torque EC Motor Configuration M = Multi-Position T = Cased Ceiling Mount S = Uncased Ceiling Mount W = Wall Mount Nominal tonnage (MBTUH) Metering Device 4 = non-bleed A/C or H/P R410 TXV F = R-22 Flo-rater 6 = 20% bleed A/C or H/P R410 TXV G = R-410A Flo-rater B = 20% bleed A/C or H/P R22 TXV X = non-bleed A/C or H/P R22 TXV Option Code Electric Heat Kit Nomenclature E C S 10 E = Fits GAM, GEM Series F = Fits GAW, GEW H = Fits GAS, GAT, GES*, GET* Power Connection 3 = 3-phase Circuit Breaker P = Circuit Breaker W/Single Point Block 4 = 3-phase Terminal Block T = Terminal Block C = Circuit Breaker L = Large Cabinet (42-61) S = Small Cabinet (18-36) Heat Strip 00 = NO Heat 08 = 8 KW 20 = 20 KW 03 = 3 KW 10 = 10 KW 24 = 24 KW (3-phase Circuit Only) 05 = 5 KW 12 = 12 KW (3-phase Circuit Only) 25 = 25 KW 06 = 6 KW 15 = 15 KW 30 = 30 KW Hydronic Heat Kit Nomenclature W C 2 S P W = Fits GBM, GFM Series U = Fits GBW, GFW Z = Fits GBS, GFT, GBS, GFT Power Connection 3 = 3-phase Circuit Breaker C = Circuit Breaker T = Terminal Block Hydronic Coil Rows Coil Dimensions L = Fits Large Chassis (42, 48, 60, 61) S = Fits Small Chassis (18, 24, 30, 36) Pump L = Less Pump and Check Valve P = with Standard Pump and Check Valve R = with 009 High Pressure Drop Pump 8 = with 008 High Pressure Drop Pump 4 Please refer to individual product specifications for additional details and a list of available options and accessories.

6 GAM SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA MULTI-POSITION ELECTRIC HEAT DX COOL AIR HANDLERS Product Dimensions & Specifications MULTI-POSITION GAM Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 01/24/ AirMark STANDARD FEATURES APPLICATION VERSATILITY Upflow or horizontal right as shipped (field-convertible for down-flow or horizontal left applications). ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. CABINET Sturdy, galvanized steel cabinet with painted front panels. Cabinet fully insulated with 1/2 faced insulation to prevent sweating and mold growth, to encapsulate glass fibers, and to provide excellent R-value. Stick pins ensure insulation remains in place. Units ship with disposable filter in filter rack. BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. 3-speed motors allow for precise air volume selection. Motor speeds can be easily selected via motor terminals. Blowers mounted on rails so they can be easily removed for service. 1 DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs are also available. Rugged GLP drain pan holds minimal condensate while eliminating the possibility of corrosion. Drain pan is UV safe. Galvanized metal drain pan (on 60/61 models only) with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4 FPT. Access door allows for coil cleaning. 5

7 MULTI-POSITION GAM MODEL GAM 18/19+ GAM 24/25 + GAM 30/31 + GAM 36/37 + GAM 42/43 + GAM 48/49 + GAM-60/61 + HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA HEAT KIT HEATING CAPACITY (MBTUH) MINIMUM CIRCUIT AMPACITY (MCA) MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S /23 56/27 50/25 60/30 E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S /23 56/27 50/25 60/30 E(C,T)L E(C,T)L E(C,T)L E(C,T)L E(C,T)L E(C,T)L E(C,T)L /23 56/27 50/25 60/30 E(C,T)L /45 58/52 60/60 60/60 E(C,T)L /45/23 58/52/26 50/50/30 60/60/30 E(C,T)L /45/45 58/52/52 50/50/50 60/60/60 E(C,T)L E(C,T)L E(C,T)L E(C,T)L E(C,T)L E(C,T)L E(C,T)L /23 56/27 50/25 60/30 E(C,T)L /45 58/52 60/60 60/60 E(C,T)L /45/23 58/52/26 50/50/30 60/60/30 E(C,T)L /45/45 58/52/52 50/50/50 60/60/60 E(C,T)L E(C,T)L E(C,T)L E(C,T)L E(C,T)L E(C,T)L E(C,T)L /23 56/27 50/25 60/30 E(C,T)L /45 58/52 60/60 60/60 E(C,T)L /45/23 58/52/26 50/50/30 60/60/30 E(C,T)L /45/45 58/52/52 50/50/50 60/60/60 2 6

8 * Wet coil MODEL MODEL AIR HANDLER CHASSIS NOMENCLATURE GAM 18 F -001 GAM = 240V PSC Motor Multi-Position Air Handler NOMINAL COOLING (BTUS) HP AMPS GAM 18/19/24/25 1/5 2.8 GAM 30/31/36/37 1/3 5.4 GAM 42/43/48/49/60/61 3/ /240V- 3 PHASE CIRCUIT BREAKER PERFORMANCE DATA HEATING (KW) Nominal tonnage (MBTUH) HEATING CAPACITY (MBTUH) BLOWER DATA CFM V. EXTERNAL STATIC* VOLTAGE SPEED LOW HIGH LOW HIGH LOW MID HIGH Metering Device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA MAX BREAKER OR FUSE SIZE 208V 204V 208V 204V 208V 204V 208V 204V GAM42-61+E GAM42-61+E315 42, ,000 GAM42-61+E324 60, / /40 GAM42-61+E /39 50/45 50/40 50/50 Option Code MULTI-POSITION GAM ELECTRIC HEAT KIT NOMENCLATURE E C S 03 Electric Heat Interruption C = Circuit Breaker T = Terminal Block P = Circuit Breaker w/single Point 3 = 3-Phase Circuit Breaker 4 = 3-Phase Terminal Block S = L = Heat strip 03 = 3 KW 05 = 5 KW 06 = 6 KW 08 = 8 KW 10 = 10 KW 12 = 12 KW 15 = 15 KW 20 = 20 KW KW 25 = 25 KW 30 = 30 KW 3 7

9 MULTI-POSITION GAM Fig 1 DIMENSIONS AND SPECIFICATIONS (In. [mm]) (Fig 1) MODEL A B C D E F G GAM18,19+E* GAM24,25+E* GAM30,31+E* GAM36,37+E* GAM42,43+E* GAM48,49+E* GAM60,61+E* 21 [53] 21 [53] 21 [53] 21 [53] 24-1/2 [62] 24-1/2 [62] 24-1/2 [62] 40 [102] 40 [102] 49 1/4 [125] 49 1/4 [125] 57 [145] 57 [145] 57 [145] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 22-1/4 [57] 22-1/4 [57] 22-1/4 [57] 12 [30] 12 [30] 12 [30] 12 [30] 10-1/2 [27] 10-1/2 [27] 10-1/2 [27] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 22 [56] 22 [56] 22 [56] 7-1/4 [18] 8-1/4 [21] 8-1/4 [21] 10-1/4 [26] 11 [28] 13 [33] 15 [38] FILTER SIZE PISTON SIZE SHIP WEIGHT (LBS) SKID QTY 10-1/4 [26] 16X /4 [31] 16X /4 [36] 16X /4 [41] 16X [41] 20X [46] 20X [51] 20X Atascocita Rd Humble, TX Phone Fax

10 GBM SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA MULTI-POSITION HYDRONIC AIR HANDLERS Product Dimensions & Specifications MULTI-POSITION GBM Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 10/27/ AirMark STANDARD FEATURES APPLICATION VERSATILITY Upflow or horizontal right as shipped (field-convertible for down-flow or horizontal left applications). CABINET Sturdy, galvanized steel cabinet with painted front panels. Cabinet fully insulated with 1/2 faced insulation to prevent sweating and mold growth, to encapsulate glass fibers, and to provide excellent R-value. Stick pins ensure insulation remains in place. Units ship with disposable filter in filter rack. ELECTRONIC CONTROL BOARD An electronic board controls the functioning of the system reducing moving parts. The board provides for various hot water supply source connections and the blower time delay to maximize heat/cool extraction. As an enhanced feature the pump circulates hot water every 6 hours to prevent coil freeze during off cycle. MODULAR HYDRONIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row. Modules are easily installed in the field using Molex plugs or can be ordered factory-installed. Freeze stat is wired into circulating pump control circuit. Controls are accessible from the front for easy service. Electrical connections can be made from the top or left. Disconnect does not protrude through the wall panel. Fan time delay relay standard for increased efficiency. Totally lead free constructed coil. Suitable for potable applications. 1 BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. 3-speed motors allow for precise air volume selection. Motor speeds can be easily selected via motor terminals. Blowers mounted on rails so they can be easily removed for service. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs are also available. Rugged GLP drain pan on 60/61 models holds minimal condensate while eliminating the possibility of corrosion. Drain pan is UV safe. All drain connections are 3/4 FPT. Access door allows for coil cleaning. 9

11 MULTI-POSITION GBM Model HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA Nominal Cooling GBM18/19 18,000 GBM24/25 24,000 GBM30/31 30,000 GBM36/37 36,000 GBM42/43 42,000 GBM48/49 48,000 GBM60/61 60,000 Model Nominal Cooling GBM18/19 18,000 GBM24/25 24,000 GBM30/31 30,000 GBM36/37 36,000 GBM42/43 42,000 GBM48/49 48,000 GBM60/61 60,000 Hydronic Heat Kit Model Rows PERFORMANCE DATA Coil P.D. (FT.WTR.) Heating Capacity BTU/HR Standard pump at 3.5 GPM Nominal Airflow Entering Water Temp W*2SP W*3SP W*2SP W*3SP W*2SP W*3SP W*4SP W*2SP W*3SP W*4SP W*2SP W*3SP W*4SP W*2SP W*3SP W*4SP W*2SP W*3SP W*4SP PERFORMANCE DATA Hydronic Heat Kit Model Rows Coil P.D. (FT.WTR.) Heating Capacity BTU/HR High Pressure Drop pump at 5 GPM Nominal Airflow Entering Water Temp W*2S W*3S W*2S W*3S W*2S W*3S W*4S W*2S W*3S W*4S W*2S W*3S W*4S W*2S W*3S W*4S W*2S W*3S W*4S ELECTRICAL DATA MINIMUM CIRCUIT AMPACITY (MCA) MAX BREAKER OR FUSE SIZE ELECTRICAL DATA MINIMUM CIRCUIT AMPACITY (MCA) MAX BREAKER OR FUSE SIZE HYDRONIC HEAT KIT NOMENCLATURE W C 2 S P Water Heat (Hydronic) Interruption C = Circuit Breaker T = Terminal Block Row S = GBM18-37 L = GBM42-61 L = Less Pump and Check Valve P = with Standard Pump and Check Valve R = with 009 High Pressure Drop Pump 8 = with 008 High Pressure Drop Pump 2 10

12 MODEL GBM18/19/24/25 GBM 30/31/36/37 GBM 42/43/48/49/60/61 * Dry coil with filter in place SPEED HP BLOWER DATA AMPS VOLTAGE CFM V. EXTERNAL STATIC* LOW /5 2.8 HIGH LOW /3 5.4 HIGH LOW MED 3/ HIGH AIR HANDLER CHASSIS NOMENCLATURE GBM 18 F -001 GBM = 120V PSC Motor Multi- Position Hydronic Air Handler Nominal tonnage (MBTUH) Metering device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV DIMENSIONS AND SPECIFICATIONS (In. [mm]) (Fig 1) MODEL A B C D E F G GBM18/19+W* GBM24/25+W* GBM30/31+W* GBM36/37+W* GBM42/43+W* GBM48/49+W* GBM60/61+W* 21 [53] 21 [53] 21 [53] 21 [53] 24-1/2 [62] 24-1/2 [62] 24-1/2 [62] 49 1/4 [125] 49 1/4 [125] 49 1/4 [125] 49 1/4 [125] 57 [145] 57 [145] 57 [145] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 22-1/4 [57] 22-1/4 [57] 22-1/4 [57] 12 [30] 12 [30] 12 [30] 12 [30] 14-3/4 [37] 14-3/4 [37] 14-3/4 [37] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 22 [56] 22 [56] 22 [56] 7-1/4 [18] 8-1/4 [21] 8-1/4 [21] 10-1/4 [26] 11 [28] 13 [33] 15 [38] 10-1/4 [26] 12-1/4 [31] 14-1/4 [36] 16-1/4 [41] 16 [41] 18 [46] 20 [51] FILTER SIZE PISTON SIZE Option Code SHIP WEIGHT (LBS) SKID QTY 16X X X X X X X MULTI-POSITION GBM Fig Atascocita Rd Humble, TX Phone Fax

13 MULTI-POSITION GEM GEM SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 01/24/ AirMark Product Dimensions & Specifications STANDARD FEATURES HIGH EFFICIENCY MULTI-POSITION ELECTRIC HEAT DX COOL AIR HANDLERS APPLICATION VERSATILITY Upflow or horizontal right as shipped (field-convertible for down-flow or horizontal left applications). For use with either R22 or R410A when proper metering device is used. Constant torque ECM speeds and torques are controlled by software embedded in the motor to maintain constant torque. Motors are pre-programmed at the factory. CABINET Sturdy, galvanized steel cabinet with painted front panels. Cabinet fully insulated with 1/2 faced insulation to prevent sweating and mold growth, to encapsulate glass fibers, and to provide excellent R-value. Stick pins ensure insulation remains in place. Units ship with disposable filter in filter rack. MODULAR ELECTRIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available from 3 to 30 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Modules are easily installed in the field using molex plugs or can be ordered factory-installed. Controls are accessible from the front for easy service. Electrical connections can be made from the top or left. Fan time delay relay standard for increased efficiency. 1 BLOWER Direct drive blowers circulate air quietly and efficiently. Motor speeds and torques programmed in the motor. Blowers mounted on rails so they can be easily removed for service. ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs are also available. Rugged, UV safe, GLP drain pan holds minimal condensate while eliminating the possibility of corrosion. All drain connections are 3/4 FPT. Access door allows for coil cleaning. 12

14 MODEL GEM18,19 GEM24,25 GEM30,31 GEM36,37 GEM42,43 GEM48,49 GEM60,61 ELECTRIC HEAT KIT MODEL E(C,T)S00 HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING (KW) HEATING CAPACITY (MBTUH) MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V E(C,T)S E(C,T)S05 18, E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S05 24, E(C,T)S E(C,T)S E(C,T)S E(C,T)S E(C,T)S ,000 E(C,T)S E(C,T)S E(C,T)S /23 56/27 50/25 55/30 E(C,T)S E(C,T)S E(C,T)S ,000 E(C,T)S E(C,T)S E(C,T)S /23 56/27 50/25 55/30 E(C,T)L E(C,T)L E(C,T)L /25 40/30 E(C,T)L15 42, /25 60/30 50/25 60/30 E(C,T)L /50 60/60 50/50 60/60 E(C,T)L /50/25 60/60/30 50/50/25 60/60/30 E(C,T)L /50/50 60/60/60 50/50/50 60/60/60 E(C,T)L E(C,T)L E(C,T)L /25 40/30 E(C,T)L15 48, /25 60/30 50/25 60/30 E(C,T)L /50 60/60 50/50 60/60 E(C,T)L /50/25 60/60/30 50/50/25 60/60/30 E(C,T)L /50/50 60/60/60 50/50/50 60/60/60 E(C,T)L E(C,T)L E(C,T)L E(C,T)L15 60, /25 60/ E(C,T)L /50 60/ E(C,T)L /50/25 60/60/ E(C,T)L /50/50 60/60/ MULTI-POSITION GEM 2 13

15 MULTI-POSITION GEM MODEL GEM 18/19/24/25 GEM 30/31/36/37 GEM 42/43/48/49/60/61 *Wet coil BLOWER DATA SPEED CFM V. EXTERNAL STATIC* TAP HP AMPS VOLTAGE TAP TAP TAP 3 1/ TAP TAP TAP TAP TAP 3 1/ TAP TAP TAP TAP TAP TAP TAP AIR HANDLER CHASSIS NOMENCLATURE GEM 18 F -001 GEM = 240V Constant Torque ECM Multi-Position Air Handler Nominal tonnage (MBTUH) Metering device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code ELECTRIC HEAT KIT NOMENCLATURE E C S 03 Electric Heat Interruption C = Circuit Breaker T = Terminal Block P = Circuit Breaker w/single Point 3 = 3-Phase Circuit Breaker 4 = 3-Phase Terminal Block S = L = Heat Strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 06 = 6 KW 08 = 8 KW 10 = 10 KW 12 = 12 KW 15 = 15 KW 20 = 20 KW KW 25 = 25 KW 30 = 30 KW 3 14

16 DIMENSIONS AND SPECIFICATIONS (In. [mm]) MODEL A B C D E F G GEM18,19+E* GEM24,25+E* GEM30,31+E* GEM36,37+E* GEM42,43+E* GEM48,49+E* GEM60,61+E* 21 [53] 40 [102] 21 [53] 40 [102] 21 [53] 49 1/4 [125] 21 [53] 49 1/4 [125] 24-1/2 [62] 24-1/2 [62] 24-1/2 [62] 57 [145] 57 [145] 57 [145] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 22-1/4 [57] 22-1/4 [57] 22-1/4 [57] 12 [30] 12 [30] 12 [30] 12 [30] 10-1/2 [27] 10-1/2 [27] 10-1/2 [27] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 22 [56] 22 [56] 22 [56] 7-1/4 [18] 8-1/4 [21] 8-1/4 [21] 10-1/4 [26] 11 [28] 13 [33] 15 [38] 10-1/4 [26] 12-1/4 [31] 14-1/4 [36] 16-1/4 [41] 16 [41] 18 [46] 20 [51] FILTER SIZE PISTON SIZE SHIP WEIGHT (LBS) SKID QTY 16X X X X X X X MULTI-POSITION GEM 373 Atascocita Rd Humble, TX Phone Fax

17 MULTI-POSITION GFM GFM SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA HIGH EFFICIENCY MULTI-POSITION HYDRONIC HEAT DX COIL AIR HANDLERS Product Dimensions & Specifications Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 10/27/ AirMark STANDARD FEATURES APPLICATION VERSATILITY Upflow or horizontal right as shipped (field-convertible for down-flow or horizontal left applications). Constant torque ECM speeds and torques are controlled by software embedded in the motor to maintain constant torque. Motors are pre-programmed at the factory. CABINET Sturdy, galvanized steel cabinet with painted front panels. Cabinet fully insulated with 1/2 faced insulation to prevent sweating and mold growth, to encapsulate glass fibers, and to provide excellent R-value. Stick pins ensure insulation remains in place. Units ship with disposable filter in filter rack. MODULAR HYDRONIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row. Heat kits are easily installed in the field using Molex plugs or can be ordered factory-installed. Freeze stat is standard, wired into circulating pump control circuit. Controls are accessible from the front for easy service. Electrical connections can be made from the top or left. Disconnect does not protrude through the wall panel. Fan time delay relay standard for increased efficiency. Heat kits are available with or without circulating pump and check valve. Units are provided with auxiliary relay for remote pump. Schrader ports are standard on water-out manifold, hose bib available as an option. 1 BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently and allow for precise air volume selection. Motor speeds and torques programmed in the motor. Blowers mounted on rails so they can be easily removed for service. ELECTRONIC CONTROL BOARD An electronic board controls the functioning of the system reducing moving parts. The board provides for various hot water supply source connections and the blower time delay to maximize heat/cool extraction. As an enhanced feature the pump circulates hot water every 6 hours to prevent coil freeze during off cycle. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquidline Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs are also available. Rugged, UV safe, GLP drain pan holds minimal condensate while eliminating the possibility of corrosion. Galvanized metal drain pan with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4 FPT. Access door allows for coil cleaning. 16

18 Model HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA Nominal Cooling GFM18/19 18,000 GFM24/25 24,000 GFM30/31 30,000 GFM36/37 36,000 GFM42/43 42,000 GFM48/49 48,000 GFM60/61 60,000 Model Nominal Cooling GFM18/19 18,000 GFM24/25 24,000 GFM30/31 30,000 GFM36/37 36,000 GFM42/43 42,000 GFM48/49 48,000 GFM60/61 60,000 Hydronic Heat Kit Model Rows PERFORMANCE DATA Coil P.D. (FT.WTR.) Heating Capacity BTU/HR Standard pump at 3.5 GPM Nominal Airflow Entering Water Temp W*2SP W*3SP W*2SP W*3SP W*2SP W*3SP W*4SP W*2SP W*3SP W*4SP W*2SP W*3SP W*4SP W*2SP W*3SP W*4SP W*2SP W*3SP W*4SP PERFORMANCE DATA Hydronic Heat Kit Model Rows Coil P.D. (FT.WTR.) Heating Capacity BTU/HR High Pressure Drop pump at 5 GPM Nominal Airflow Entering Water Temp W*2S W*3S W*2S W*3S W*2S W*3S W*4S W*2S W*3S W*4S W*2S W*3S W*4S W*2S W*3S W*4S W*2S W*3S W*4S ELECTRICAL DATA MINIMUM CIRCUIT AMPACITY (MCA) MAX BREAKER OR FUSE SIZE ELECTRICAL DATA MINIMUM CIRCUIT AMPACITY (MCA) MAX BREAKER OR FUSE SIZE MULTI-POSITION GFM 2 17

19 MULTI-POSITION GFM *Dry coil MODEL GFM 18/19/24/25 GFM 30/31/36/37 GFM 42/43/48/60/61 SPEED TAP TAP 5 HP AMPS BLOWER DATA VOLTAGE CFM V. EXTERNAL STATIC* TAP TAP 3 1/ TAP TAP TAP TAP TAP 3 1/ TAP TAP TAP TAP TAP TAP TAP AIR HANDLER CHASSIS NOMENCLATURE GFM 18 G -001 GFM = 120V Constant Torque ECM Multi-Position Air Handler Nominal tonnage (MBTUH) Metering device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code HYDRONIC HEAT KIT NOMENCLATURE W C 2 S P Water heat (hydronic) Interruption C = Circuit Breaker T = Terminal Block Row S = GFM18-37 L = GFM42-61 L = Less Pump and Check Valve P = with Standard Pump and Check Valve R = with 009 High Pressure Drop Pump 8 = with 008 High Pressure Drop Pump 3 18

20 DIMENSIONS AND SPECIFICATIONS (In. [mm]) MODEL A B C D E F G GFM18/19+W* GFM24/25+W* GFM30/31+W* GFM36/37+W* GFM42/43+W* GFM48/49+W* GFM60/61+W* 21 [53] 21 [53] 21 [53] 21 [53] 24-1/2 [62] 24-1/2 [62] 24-1/2 [62] 49 1/4 [125] 49 1/4 [125] 49 1/4 [125] 49 1/4 [125] 57 [145] 57 [145] 57 [145] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 22-1/4 [57] 22-1/4 [57] 22-1/4 [57] 12 [30] 12 [30] 12 [30] 12 [30] 14-3/4 [37] 14-3/4 [37] 14-3/4 [37] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 22 [56] 22 [56] 22 [56] 7-1/4 [18] 8-1/4 [21] 8-1/4 [21] 10-1/4 [26] 11 [28] 13 [33] 15 [38] 10-1/4 [26] 12-1/4 [31] 14-1/4 [36] 16-1/4 [41] 16 [41] 18 [46] 20 [51] FILTER SIZE PISTON SIZE SHIP WEIGHT (LBS) SKID QTY 16X X X X X X X WALL MOUNT GFM Atascocita Rd Humble, TX Phone Fax

21 GAW GAW SERIES VERTICAL WALL MOUNT ELECTRIC HEAT DX COIL AIR HANDLERS WALL MOUNT WARRANTY One year limited parts warranty OPTIONS See options menu Product Dimensions & Specifications MANUFACTURED IN THE USA Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. STANDARD FEATURES APPLICATION VERSATILITY Front or bottom return air position. Offset hanging brackets attach to unit and wall to allow hanging inside closet. For use with either R22 or R410A when proper metering device is used. LOW LEAKAGE CABINET Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to Aspen installation instructions. Sturdy, fully insulated galvanized steel cabinet. ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. MODULAR ELECTRIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 0, 3, 5, 8, & 10 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Modules are easily installed in the field using molex plugs or can be ordered factory-installed. Controls are accessible from the front for easy service. Electrical connections can be made from the top or left. Disconnect does not protrude through the wall panel. Fan time delay relay standard for increased efficiency. BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. Motor speeds can be easily selected via motor terminals. Swing mounted blowers can be easily removed for service. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either check style flowrater or TXV metering device factory installed. Field-installable TXVs are also available. Galvanized metal drain pan with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4 FPT. Access door allows for coil cleaning. Rev. Date: 08/11/ AirMark 1 20

22 MODEL GAW18 GAW23 GAW24 GAW30 GAW36 HEAT KIT HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING CAPACITY HEATING (KW) (MBTUH) MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V F(C,T)S F(C,T)S F(C,T)S05 18, F(C,T)S F(C,T)S F(C,T)S F(C,T)S F(C,T)S05 23, F(C,T)S F(C,T)S F(C,T)S F(C,T)S F(C,T)S05 24, F(C,T)S F(C,T)S F(C,T)S F(C,T)S F(C,T)S05 30, F(C,T)S F(C,T)S F(C,T)S F(C,T)S F(C,T)S05 36, F(C,T)S F(C,T)S WALL MOUNT GAW BLOWER DATA MODEL HP AMPS VOLTAGE GAW18/23/24 1/ GAW30/36 1/ * Wet coil with filter, - For 208 V multiply by 0.90 CFM V. EXTERNAL STATIC* SPEED LOW HIGH LOW HIGH AIR HANDLER CHASSIS NOMENCLATURE GAW 18 F -001 GAW = 240V PSC Motor Vertical Wall Mount Nominal tonnage (MBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code 2 21

23 WALL MOUNT GAW ELECTRIC HEAT KIT NOMENCLATURE F C S 05 Wall Mount Electric Heat Interruption C = Circuit Breaker T = Terminal Block S = DIMENSIONS AND SPECIFICATIONS (In. [mm]) (Fig 1) MODEL A B C D E F GAW18* GAW23* GAW24* GAW30* GAW36* 37-1/2 [95] 37-1/2 [95] 37-1/2 [95] 40-1/2 [103] 40-1/2 [103] 22 [56] 22 [56] 22 [56] 22 [56] 22 [56] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 14 [36] 14 [36] 14 [36] 14 [36] 14 [36] 10 [25] 10 [25] 10 [25] 11-1/2 [29] 11-1/2 [29] FILTER SIZE PISTON SIZE Heat strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 08 = 8 KW 10 = 10KW SHIP WEIGHT (LBS) SKID QTY 3-1/4 [8.3] 20X /4 [8.3] 20X /4 [8.3] 20X /8 [3.5] 20X /8 [3.5] 20X Fig 1 INSTALLATION CLEARANCES OPERATION SERVICE TOP 0 0 FRONT 0 30 SIDES 0 0 REAR

24 Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with powder paint and smooth finish. Can be latex painted in the field. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. Fig 2 WALL MOUNT GAW PANEL MODEL ACCESS PANEL DIMENSIONS AND SPECIFICATIONS (Fig 2) FOR USE WITH FINISH OPENING SIZE PANEL DIMENSION FRAME DIMENSION # OF PANELS A B C D E F WAD-7(S/L) GAW 18/24 Embossed 22 1/4 39 1/2 24 1/4 41 1/2 24 1/8 41 3/8 1 WAD-8(S/L) GAW 30/36 Embossed 22 1/4 42 1/2 24 1/4 44 1/2 24 1/8 44 3/8 1 WAD-18(S/L) GAW 18/24 Smooth 22 1/4 39 1/2 24 1/4 41 1/2 24 1/8 41 3/8 1 WAD-19(S/L) GAW 30/36 Smooth 22 1/4 42 1/2 24 1/4 44 1/2 24 1/8 44 3/ Atascocita Rd Humble, TX Phone Fax

25 WALL MOUNT GBW GBW SERIES WARRANTY One year limited parts warranty OPTIONS WALL MOUNT HYDRONIC HEAT DX COOL AIR HANDLERS Product Dimensions & Specifications See options menu MANUFACTURED IN THE USA Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 05/11/ AirMark STANDARD FEATURES APPLICATION VERSATILITY Front or bottom return air. Offset hanging brackets attach to unit and wall to allow hanging inside closet. Can be DOE matched with most brands of air conditioners or heat pumps. ETL listed for use with either R22 or R410A when a proper metering device is used. LOW LEAKAGE CABINET Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to Aspen installation instructions. Sturdy, fully insulated galvanized steel cabinet. ELECTRONIC CONTROL BOARD An electronic board controls the functioning of the system reducing moving parts. The board provides for various hot water supply source connections and the blower time delay to maximize heat/cool extraction. As an enhanced feature the pump circulates hot water every 6 hours to prevent coil freeze during off cycle. MODULAR HYDRONIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row, providing 16,000 to 59,000 BTU s of heat. Heat kits are easily installed in the field using molex plugs or can be ordered factory-installed. Freeze stat is standard, wired into circulating pump control circuit. Controls are accessible from the front for easy service. Electrical connections can be made from the top or left. Disconnect does not protrude through the wall panel. 1 Fan time delay relay standard for increased efficiency. Heat kits are available with or without bronze circulating pump and check valve. Units are provided with auxiliary relay for remote pump. Schrader ports are standard on water-out manifold, hose bib available as an option. Totally lead free constructed coil. Suitable for potable applications. BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. Motor speeds can be easily selected via motor terminals. Swing mounted blowers can be easily removed for service. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquidline Schrader allows pre-installation pressure testing. Available with either factory installed check style flowrater or TXV metering device. Field-installable TXVs are also available. Galvanized metal drain pan with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4 FPT. Access door allows for coil cleaning. 24

26 UNIT MODEL GBW 18 GBW 24 GBW 30 GBW 36 MODEL HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA HYDRONIC HEAT KIT MODEL HP NOMINAL COOLING (BTUS) AMPS GBW18 & GBW 24 1/5 2.8 GBW30 & GBW36 1/3 5.4 PERFORMANCE DATA HEATING COIL BLOWER DATA VOLTAGE 120 Hydronic Coil Delta P. SPEED Heating 3.5 GPM ENTERING WATER TEMP ROW Ft.Water 120º 140º 180º U(C,T)2S(P,L) ,800 26,600 42,300 18,000 U(C,T)3S(P,L) ,600 30,400 48,500 U(C,T)2S(P,L) ,000 30,100 48,000 24,000 U(C,T)3S(P,L) ,700 34,800 55,600 U(C,T)2S(P,L) ,200 32,800 52,500 U(C,T)3S(P,L) 30, ,000 38,200 61,100 U(C,T)4S(P,L) ,300 40,100 64,000 U(C,T)2S(P,L) ,700 35,000 56,000 U(C,T)3S(P,L) 36, ,900 41,000 65,500 U(C,T)4S(P,L) ,400 43,000 68,800 ELECTRICAL DATA MINIMUM MAX CIRCUIT BREAKER OR AMPACITY FUSE SIZE (MCA) CFM V. EXTERNAL STATIC* LOW HIGH LOW HIGH WALL MOUNT GBW * Dry coil AIR HANDLER CHASSIS NOMENCLATURE GBW 18 F -001 GBW = 120V PSC Motor Vertical Wall Mount Nominal tonnage (MBTUH) Metering device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code HYDRONIC HEAT KIT NOMENCLATURE U C 2 S P Wall Mount Hydronic Heat Interruption C = Circuit Breaker T = Terminal Block # of rows 2 = 2 rows 3 = 3 rows 4 = 4 rows S = P = Taco 006 Bronze Pump 8 = Taco 008 Bronze Pump L = Less pump 2 25

27 DIMENSIONS AND SPECIFICATIONS (In. [mm]) (Fig 1) WALL MOUNT MODEL A B C D E GBW18* GBW24* GBW30* GBW36* Fig /2 (113) 44-1/2 (113) 44-1/2 (113) 44-1/2 (113) 22 (56) 22 (56) 22 (56) 22 (56) 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 17-5/8 (45) 17-5/8 (45) 17-5/8 (45) 17-5/8 (45) 10-1/2 (27) 10-1/2 (27) 10-1/2 (27) 10-1/2 (27) FILTER SIZE PISTON SIZE SHIP WEIGHT (LBS) SKID QTY 20X X X X INSTALLATION CLEARANCES OPERATION SERVICE TOP 0 0 FRONT 0 30 SIDES 0 0 REAR

28 Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with powder paint and smooth finish. Can be latex painted in the field. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. Fig 2 WALL MOUNT PANEL MODEL ACCESS PANEL DIMENSIONS AND SPECIFICATIONS (Fig 2) FOR USE WITH FINISH OPENING SIZE PANEL DIMENSION FRAME DIMENSION # OF PANELS A B C D E F WAD-9(S/L) GBW Embossed 22 1/ / /8 47 7/8 1 WAD-10(S/L) GBW Embossed 22 1/ / /8 53 7/8 1 WAD-16(S/L) GBW Smooth 22 1/ / /8 53 7/8 1 WAD-17(S/L) GBW Smooth 22 1/ / /8 47 7/ Atascocita Rd Humble, TX Phone Fax

29 WALL MOUNT GEW GEW SERIES WARRANTY One year limited parts warranty OPTIONS HIGH EFFICIENCY VERTICAL WALL MOUNT ELECTRIC HEAT DX COIL AIR HANDLERS Product Dimensions & Specifications See options menu MANUFACTURED IN THE USA STANDARD FEATURES APPLICATION VERSATILITY Front or bottom return air position. Offset hanging brackets attach to unit and wall to allow hanging inside closet. Can be DOE matched with most brands of air conditioners or heat pumps. ETL listed for use with either R22 or R410A when a proper metering device is used. made from the top or left. Disconnect does not protrude through the wall panel. Fan time delay relay standard for increased efficiency. BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. Motor speeds can be easily selected via motor terminals. Swing mounted blowers can be easily removed for service. Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 06/30/ AirMark Constant torque ECM speeds and torques are controlled by software embedded in the motor to maintain constant torque. Motors are pre-programmed at the factory. LOW LEAKAGE CABINET Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to Aspen installation instructions. Sturdy, fully insulated galvanized steel cabinet. MODULAR ELECTRIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 3, 5, 8, & 10 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Modules are easily installed in the field using molex plugs or can be ordered factory-installed. Controls are accessible from the front for easy service. Electrical connections can be 1 ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either check style flowrater or TXV metering device factory installed. Field-installable TXVs are also available. Galvanized metal drain pan with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4 FPT. Access door allows for coil cleaning. 28

30 MODEL GEW18 GEW23 GEW24 GEW30 GEW36 HEAT KIT HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING CAPACITY HEATING (KW) (MBTUH) MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V F(C,T)S F(C,T)S F(C,T)S05 18, F(C,T)S F(C,T)S F(C,T)S F(C,T)S F(C,T)S05 23, F(C,T)S F(C,T)S F(C,T)S F(C,T)S F(C,T)S05 24, F(C,T)S F(C,T)S F(C,T)S F(C,T)S F(C,T)S05 30, F(C,T)S F(C,T)S F(C,T)S F(C,T)S F(C,T)S05 36, F(C,T)S F(C,T)S WALL MOUNT GEW BLOWER DATA MODEL HP AMPS GEW 18/23/24 1/3 2.8 GEW 30/36 1/2 4.1 * Wet coil with filter For 208 operation multiply by 0.90 VOLTAGE 240 SPEED TAP CFM V. EXTERNAL STATIC* TAP TAP TAP TAP TAP TAP TAP TAP TAP TAP AIR HANDLER CHASSIS NOMENCLATURE GEW 18 F -001 GEW = 240V Constant Torque ECM Vertical Wall Mount Nominal tonnage (MBTUH) Metering device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code 2 29

31 WALL MOUNT GEW ELECTRIC HEAT KIT NOMENCLATURE F C S 03 Wall Mount Electric Heat Interruption C = Circuit Breaker T = Terminal Block S = DIMENSIONS AND SPECIFICATIONS (In. [mm]) (Fig 1) MODEL A B C D E F GEW18* GEW23* GEW24* GEW30* GEW36* 37-1/2 [95] 37-1/2 [95] 37-1/2 [95] 40-1/2 [103] 40-1/2 [103] 22 [56] 22 [56] 22 [56] 22 [56] 22 [56] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 14 [36] 14 [36] 14 [36] 14 [36] 14 [36] 10 [25] 10 [25] 10 [25] 11-1/2 [29] 11-1/2 [29] FILTER SIZE PISTON SIZE Heat Strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 08 = 8 KW 10 = 10 KW SHIP WEIGHT (LBS) SKID QTY 3-1/4 [8.3] 20X /4 [8.3] 20X /4 [8.3] 20X /8 [3.5] 20X / [3.5] 20X Fig 1 INSTALLATION CLEARANCES OPERATION SERVICE TOP 0 0 FRONT 0 30 SIDES 0 0 REAR

32 Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with powder paint and smooth finish. Can be latex painted in the field. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. Fig 2 WALL MOUNT GEW PANEL MODEL ACCESS PANEL DIMENSIONS AND SPECIFICATIONS (Fig 2) FOR USE WITH FINISH OPENING SIZE PANEL DIMENSION FRAME DIMENSION # OF PANELS A B C D E F WAD-7(S/L) GEW 18/24 Embossed 22 1/4 39 1/2 24 1/4 41 1/2 24 1/8 41 3/8 1 WAD-8(S/L) GEW 30/36 Embossed 22 1/4 42 1/2 24 1/4 44 1/2 24 1/8 44 3/8 1 WAD-18(S/L) GEW 18/24 Smooth 22 1/4 39 1/2 24 1/4 41 1/2 24 1/8 41 3/8 1 WAD-19(S/L) GEW 30/36 Smooth 22 1/4 42 1/2 24 1/4 44 1/2 24 1/8 44 3/ Atascocita Rd Humble, TX Phone Fax

33 WALL MOUNT GFW GFW SERIES WARRANTY One year limited parts warranty OPTIONS See options menu HIGH EFFICIENCY WALL MOUNT HYDRONIC HEAT DX COOL AIR HANDLERS Product Dimensions & Specifications MANUFACTURED IN THE USA Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 05/11/ AirMark STANDARD FEATURES APPLICATION VERSATILITY Front or bottom return air. Offset hanging brackets included standard attach to unit and wall to allow hanging inside closet. Can be DOE matched with most brands of air conditioners or heat pumps. ETL listed for use with either R22 or R410A when a proper metering device is used. Constant torque ECM speeds and torques are controlled by software embedded in the motor to maintain constant torque. Motors are pre-programmed at the factory. LOW LEAKAGE CABINET Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to Aspen installation instructions. Sturdy, fully insulated galvanized steel cabinet. MODULAR HYDRONIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row, providing 16,000 to 59,000 BTU s of heat. Heat kits are easily installed in the field using molex plugs or can be ordered factory-installed. Freeze stat is standard, wired into circulating pump control circuit. Controls are accessible from the front for easy service. Electrical connections can be made from the top or left. Disconnect does not protrude through the wall panel. Fan time delay relay standard for increased efficiency. Heat kits are available with or without circulating pump and check valve. Units are provided with auxiliary relay for remote pump. Schrader ports are 1 standard on water-out manifold, hose bib available as an option. Totally lead free constructed coil. Suitable for potable applications. BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. Motor speeds can be easily selected via motor terminals. Swing mounted blowers can be easily removed for service. ELECTRONIC CONTROL BOARD An electronic board controls the functioning of the system reducing moving parts. The board provides for various hot water supply source connections and the blower time delay to maximize heat/cool extraction. As an enhanced feature the pump circulates hot water every 6 hours to prevent coil freeze during off cycle. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with factory installed check style flowrater or TXV metering device. Field-installable TXVs are also available. Galvanized metal drain pan with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4 FPT. Access door allows for coil cleaning. 32

34 MODEL GFW18 GFW24 GFW30 GFW36 MODEL GFW18 & GFW 24 GFW30 & GFW36 HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA HYDRONIC HEAT KIT NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING COIL HEATING CAPACITY 3.5 GPM ENTERING WATER TEMP ROWS SIZE 120 O 140 O 180 O U(C,T)2S(P,L) 2 18,800 26,600 42,300 18,000 U(C,T)3S(P,L) 3 21,600 30,400 48,500 U(C,T)2S(P,L) 2 21,000 30,100 48,000 24,000 U(C,T)3S(P,L 3 24,700 34,800 55,600 U(C,T)2S(P,L) 2 23,200 32,800 52, x10-1/2 U(C,T)3S(P,L) 30, ,000 38,200 61,100 U(C,T)4S(P,L) 4 28,300 40,100 64,000 U(C,T)2S(P,L) 2 24,700 35,000 56,000 U(C,T)3S(P,L) 36, ,900 41,000 65,500 U(C,T)4S(P,L) 4 30,400 43,000 68,800 BLOWER DATA ELECTRICAL DATA MINIMUM CIRCUIT AMPACITY (MCA) MAX BREAKER OR FUSE SIZE SPEED CFM V. EXTERNAL STATIC* TAP HP AMPS VOLTAGE TAP TAP TAP 3 1/ TAP TAP TAP TAP TAP 3 1/ TAP TAP WALL MOUNT GFW *Dry coil with filter AIR HANDLER CHASSIS NOMENCLATURE GFW 18 G -001 GFW = 115V Constant Torque ECM Vertical Wall Mount Nominal tonnage (MBTUH) Metering device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code HYDRONIC HEAT KIT NOMENCLATURE U C 2 S P Wall Mount Hydronic Heat Interruption C = Circuit Breaker T = Terminal Block # of rows 2 = 2 rows 3 = 3 rows 4 = 4 rows S = P = Taco 006 Bronze Pump 8 = Taco 008 Bronze Pump L = less pump 2 33

35 WALL MOUNT GFW MODEL GFW18* GFW24* GFW30* GFW36* Fig 1 HEIGHT A 44-1/2 (113) 44-1/2 (113) 44-1/2 (113) 44-1/2 (113) DIMENSIONS AND SPECIFICATIONS (In. [mm]) (Fig 1) WIDTH B 22 (56) 22 (56) 22 (56) 22 (56) DEPTH C 18 3/4 (48) 18 3/4 (48) 18 3/4 (48) 18 3/4 (48) D 17 5/8 (45) 17 5/8 (45) 17 5/8 (45) 17 5/8 (45) E 10-1/2 (27) 10-1/2 (27) 10-1/2 (27) 10-1/2 (27) FILTER SIZE PISTON SIZE INSTALLATION CLEARANCES OPERATION SHIP WEIGHT (LBS) SERVICE TOP 0 0 FRONT 0 30 SIDES 0 0 REAR 0 0 SKID QTY 20X X X X

36 Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with powder paint and smooth finish. Can be latex painted in the field. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. Fig 2 WALL MOUNT GFW PANEL MODEL ACCESS PANEL DIMENSIONS AND SPECIFICATIONS (Fig 2) FOR USE WITH FINISH OPENING SIZE PANEL DIMENSION FRAME DIMENSION # OF PANELS A B C D E F WAD-9(S/L) GFW Embossed 22 1/ / /8 47 7/8 1 WAD-10(S/L) GFW Embossed 22 1/ / /8 53 7/8 1 WAD-16(S/L) GFW Smooth 22 1/ / /8 53 7/8 1 WAD-17(S/L) GFW Smooth 22 1/ / /8 47 7/ Atascocita Rd Humble, TX Phone Fax

37 CEILING MOUNT GAS GAS SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA UNCASED CEILING MOUNT ELECTRIC HEAT DX COOL AIR HANDLER Product Dimensions & Specifications Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. STANDARD FEATURES APPLICATION VERSATILITY Built in mounting tabs for ceiling or furrdown mounting. Louvered ceiling access panel has separate frame that attaches to ceiling joists. Solid access panel available for use with end return installations. Compatible with most brands of air conditioners or heat pumps. Direct drive multi-speed blowers circulate air quietly and efficiently. Two speed motors allow for precise air volume selection. Motor speeds can be easily selected via motor terminals. Blowers mounted on plate so they can be easily removed for service. ELECTRIC HEAT KITS Heat kits available in 3, 5, 6, 8, & 10 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Easily accessible controls for quick service. ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs are also available. Primary & secondary condensate drain. All drain connections are 3/4 MPT. Powder-painted metal drain pan. Access door allows for coil cleaning. Certified for use with either R22 or R410A. Rev. Date: 11/03/ AirMark 1 36

38 MODEL GAS 18/19/20 GAS 24/25 GAS 26/28 GAS 30/31/32 GAS 36/37 UNIT MODEL GAS 18/19/24 GAS 20/25 GAS 26 GAS 28 GAS 30 GAS 31 GAS 32 HEAT KIT HTS00 HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING KW HEATING KBTUH MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA HIGH GAS 36/37 LOW Note: Units should not be applied to a system with less than 350 CFM/Ton airflow. Add static when enclosure and/or ceiling panel are used. MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V HTS HTS05 18, HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS SPEED TAP HIGH HP BLOWER DATA CFM VS. STATIC PRESSURE LOW HIGH LOW /4 HIGH LOW HIGH LOW HIGH LOW HIGH LOW /3 HIGH LOW CEILING MOUNT GAS 37

39 CEILING MOUNT GAS AIR HANDLER CHASSIS NOMENCLATURE G A S 18 G -001 Voltage Configuration Option Code A = 240V PSC Motor S = Uncased Ceiling Mount AirMark Air Handler ENCLOSURES DIMENSIONS Nominal Tonnage (KBTUH) ELECTRIC HEAT KIT NOMENCLATURE UNIT MODEL A B C Weight (lbs) Skid Qty. GAS 18/19/ /4 34-5/ GAS 20/25/ /4 40-5/ GAS 26/31/ /4 46 5/ GAS 28/32/ /4 53 5/ Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV H T S 10 H = Fits GAS, GAT, GES, GET T = Terminal Block S = Small Cabinet (18-37) Heat Strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 06 = 6 KW 08 = 8 KW 10 = 10 KW 3 38

40 Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. FOR USE WITH ACCESS DOOR DIMENSIONS PANEL MODEL GAS ACCESS DOOR AND FRAME A B C D GAS 18/19/24 GAD-1(S/L) 43-1/2 27-1/2 41-1/2 26 GAS 20/25/30 GAD-5(S/L) 49-1/2 27-1/2 47-1/2 26 GAS 26/31/36 GAD-2(S/L) 55-1/2 27-1/2 53-1/2 26 GAS 28/32/37 GAD-6(S/L) 63-1/2 27-1/2 61-1/2 26 CEILING MOUNT GAS 373 Atascocita Rd Humble, TX Phone Fax

41 CEILING MOUNT GAT GAT SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA CASED CEILING MOUNT ELECTRIC HEAT DX COOL AIR HANDLER Product Dimensions & Specifications STANDARD FEATURES APPLICATION VERSATILITY Built in mounting tabs for ceiling or furrdown mounting. Louvered ceiling access panel has separate frame that attaches to ceiling joists. Solid access panel available for use with end return installations. Compatible with most brands of air conditioners or heat pumps. ELECTRIC HEAT KITS Heat kits available in 3, 5, 6, 8, & 10 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Easily accessible controls for quick service. ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Direct drive multi-speed blowers circulate air quietly and efficiently. Two speed motors allow for precise air volume selection. Motor speeds can be easily selected via motor terminals. Blowers mounted on plate so they can be easily removed for service. LOW LEAKAGE CABINET Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to Airmark installation instructions. Sturdy, fully insulated galvanized steel cabinet with knockout for duct return. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs are also available. Primary & secondary condensate drain. All drain connections are 3/4 NPT. Powder-painted metal drain pan. Access door allows for coil cleaning. Certified for use with either R22 or R410A. Rev. Date: 11/03/ AirMark 1 40

42 MODEL GAT 18/19/20 GAT 24/25 GAT 26/28 GAT 30/31/32 GAT 36/37 UNIT MODEL GAT 18/19/24 GAT 20/25 GAT 26 GAT 28 GAT 30 GAT 31 GAT 32 HEAT KIT HTS00 HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING KW HEATING KBTUH MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA HIGH GAT 36/37 LOW Note: Units should not be applied to a system with less than 350 CFM/Ton airflow. Add static when enclosure and/or ceilling panel are used. MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS SPEED TAP HIGH HP BLOWER DATA CFM VS. STATIC PRESSURE LOW HIGH LOW /4 HIGH LOW HIGH LOW HIGH LOW HIGH LOW /3 HIGH LOW CEILING MOUNT GAT 41

43 CEILING MOUNT GAT AirMark Air Handler AIR HANDLER CHASSIS NOMENCLATURE G A T 18 G -001 Voltage Configuration Nominal Option Code A = 240V PSC Motor T = Cased Ceiling Mount Tonnage B = 120V PSC Motor (KBTUH) ELECTRIC HEAT KIT NOMENCLATURE Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV H T S 10 H = Fits GAS, GAT, GES, GET T = Terminal Block S = Small Cabinet (18-37) Heat Strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 06 = 6 KW 08 = 8 KW 10 = 10 KW ENCLOSURES DIMENSIONS UNIT MODEL A B C Weight (lbs) Skid Qty. GAT 18/19/ GAT 20/25/ GAT 26/31/ GAT 28/32/

44 Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. FOR USE WITH ACCESS DOOR DIMENSIONS PANEL MODEL GAT ACCESS DOOR AND FRAME A B C D GAT 18/19/24 GAD-1(S/L) 43-1/2 27-1/2 41-1/2 26 GAT 20/25/30 GAD-5(S/L) 49-1/2 27-1/2 47-1/2 26 GAT 26/31/36 GAD-2(S/L) 55-1/2 27-1/2 53-1/2 26 GAT 28/32/37 GAD-6(S/L) 63-1/2 27-1/2 61-1/2 26 CEILING MOUNT GAT CAP KIT PART NUMBER Part Number Model Number Enclosure Size CAP-1 GAT18/19/24 40"X24"X11" CAP-2 GAT20/25/30 46"X24"X11" CAP-3 GAT 26/31/36 52"X24"X11" CAP-4 GAT 28/32/37 60"X24"X11" Note: CAP kit is an insulated panel that covers the entire bottom opening and is utilized for optional ducted return configuration 373 Atascocita Rd Humble, TX Phone Fax

45 CEILING MOUNT GBS GBS SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA UNCASED CEILING MOUNT HYDRONIC HEAT DX COIL AIR HANDLER Product Dimensions & Specifications Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 10/26/ AirMark STANDARD FEATURES Factory installed service switch Factory installed freeze protection Rifled copper tube/enhanced aluminum fins DX and hydronic coils for more efficient heat transfer Schrader valve on DX and hydronic coils for hisstest leak check Low leak cabinet design* APPLICATION VERSATILITY Built-in mounting tabs for ceiling or furdown mounting. Compatible with most brands of air conditioners and heat pumps. Optional louvered ceiling access panel has separate frame that attached to ceiling joists. Optional solid ceiling panel available for use with ducted return. Less than 2% air leakage (* when tested in accordance with ASHRAE standard 193 and AirMark installation instructions.) Direct drive blowers circulate air quietly and efficiently. Multiple speeds allow for precise air volume selection. Air moving system is plated mounted to allow for easy removal and service. 1 ELECTRONIC CONTROLS Electronic board controls the functioning of system, increasing system reliability. Standard factory installed freeze stat wired into circulating pump control circuit. Standard factory installed fan time delay relay for increased efficiency and maximize capacity. Standard factory installed pump cycle timer circulates hot water every four hours to prevent coil freeze during off-cycle. DX/HYDRONIC COILS High efficiency rifled copper tube and enhanced aluminum fins provide maximum heat transfer. All coils are immersion tested at 500 PSI and nitrogen charged for maximum reliability. Schrader valve allows for hiss-test pre-installation pressure test. Available with factory installed orifice or TXV. Primary and secondary DX condensate drain with ¾ NPT connections. Powder-painted galvanized drain pan. Certified for use with R22 or R410A. Lead free construction. 44

46 MODEL GBS 18 GBS 19/24 GBS 25 GBS 30 GBS 31/36 HEATING AND COOLING PERFORMANCE & ELECTRICAL DATA PERFORMANCE DATA MODEL NOMINAL PRESS. BTU (1000) AT ENTERING WATER TEMPERATURE F HEATING COOLING DROP GPM (BTUS) (FT. WTR) GBS 18 18, GBS 19/24 24, GBS 25 24, GBS 30 30, GBS 31/36 36, NOTES: Heat BTUH is at 70 degree EAT. 120 degree and 180 degree data is supplied for boiler applications. Heat BTUH output will not exceed output of water heater. BLOWER DATA SPEED CFM VS. STATIC PRESSURE AMP VOLT HP TAP HIGH /4 LOW HIGH /4 LOW HIGH /3 LOW HIGH /5 (2) LOW HIGH /5 (2) LOW Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 0.05 static when enclosure and/or ceiling panel are used. GBS 30, GBS31 and GBS 36 have two motors and four blowers. CEILING MOUNT GBS AIR HANDLER CHASSIS NOMENCLATURE G B S 18 G -001 AirMark Air Handler Voltage B = 120V PSC Motor Configuration S = Uncased Ceiling Mount Nominal Tonnage (KBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code HYDRONIC HEAT KIT NOMENCLATURE Z T 2 S P Water Heat Hydronic Terminal Block 2 = 2 Row Hydronic Coil GBS 18 - X GBS 19/24 - S GBS - 25/30 - M GBS 31/36 - L P = Taco 006 Bronze Pump 8 = Taco 008 Bronze Pump L = Less Pump 2 45

47 CEILING MOUNT GBS PHYSICAL DIMENSIONS UNIT MODEL A B C D Weight (lbs) Skid Qty. GBS GBS GBS GBS GBS (GBS 18-25) Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. FOR USE WITH ACCESS DOOR DIMENSIONS PANEL MODEL (GBS 30-36) GAS ACCESS DOOR AND FRAME A B C D GBS 18 GAD-5(S/L) 49 1/2 27 1/2 47 1/2 26 GBS 19/24 GAD-3(S/L) 55 1/2 27 1/2 53 1/2 26 GBS 25/30 GAD-6(S/L) 63-1/2 27 1/2 61-1/2 26 FILTER 20 x 20 x 1 field supplied. GBS 31/36 GAD-4(S/L) 70-1/2 27 1/2 68-1/2 26 WARRANTY One-year limited parts warranty Atascocita Rd Humble, TX Phone Fax

48 GBT SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA CASED CEILING MOUNT HYDRONIC HEAT DX COIL AIR HANDLER Product Dimensions & Specifications CEILING MOUNT GBT Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 10/27/ AirMark STANDARD FEATURES Factory installed service switch Factory installed freeze protection Rifled copper tube/enhanced aluminum fins DX and hydronic coils for more efficient heat transfer Schrader valve on DX and hydronic coils for hisstest leak check Low leak cabinet design* APPLICATION VERSATILITY Built-in mounting tabs for ceiling or furdown mounting. Compatible with most brands of air conditioners and heat pumps. Optional louvered ceiling access panel has separate frame that attached to ceiling joists. Optional solid ceiling panel available for use with ducted return. Less than 2% air leakage (* when tested in accordance with ASHRAE standard 193 and AirMark installation instructions.) Fully insulated galvanized steel cabinet with knockout for ducted return. Direct drive blowers circulate air quietly and efficiently. Multiple speeds allow for precise air volume selection. Air moving system is plated mounted to allow for easy removal and service. 1 ELECTRONIC CONTROLS Electronic board controls the functioning of system, increasing system reliability. Standard factory installed freeze stat wired into circulating pump control circuit. Standard factory installed fan time delay relay for increased efficiency and maximize capacity. Standard factory installed pump cycle timer circulates hot water every four hours to prevent coil freeze during off-cycle. DX/HYDRONIC COILS High efficiency rifled copper tube and enhanced aluminum fins provide maximum heat transfer. All coils are immersion tested at 500 PSI and nitrogen charged for maximum reliability. Schrader valve allows for hiss-test pre-installation pressure test. Available with factory installed orifice or TXV. Primary and secondary DX condensate drain with ¾ NPT connections. Powder-painted galvanized drain pan. Certified for use with R22 or R410A. Lead free construction. 47

49 CEILING MOUNT GBT MODEL HEATING AND COOLING PERFORMANCE & ELECTRICAL DATA NOMINAL COOLING (BTUS) GBT 18 18,000 GBT 19/24 24,000 GBT 25 24,000 GBT 30 30,000 GBT 31/36 36,000 PERFORMANCE DATA PRESS. BTU (1000) AT ENTERING WATER TEMPERATURE F HEATING DROP GPM (FT. WTR) NOTES: Heat BTUH is at 70 degree EAT. 120 degree and 180 degree data is supplied for boiler applications. Heat BTUH output will not exceed output of water heater. BLOWER DATA CFM VS. STATIC PRESSURE UNIT MODEL RPM AMP VOLT HP GBT 18 HIGH /4 LOW GBT 19/24 HIGH /4 LOW GBT 25 HIGH /3 LOW GBT 30 HIGH /5 (2) LOW GBT 31/36 HIGH /5 (2) LOW Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 0.05 static when enclosure and/or ceiling panel are used. GBT 30, GBT 31 and GBT 36 have two motors and four blowers. AIR HANDLER CHASSIS NOMENCLATURE G B T 18 G -001 AirMark Air Handler Voltage B = 120V PSC Motor Configuration T = Cased Ceiling Mount Nominal Tonnage (KBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code HYDRONIC HEAT KIT NOMENCLATURE Z T 2 S P Water Heat Hydronic Terminal Block 2 = 2 Row Hydronic Coil GBT 18 - X GBT 19/24 - S GBT - 25/30 - M GBT 31/36 - L P = Taco 006 Bronze Pump 8 = Taco 008 Bronze Pump L = Less Pump 2 48

50 Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. ENCLOSURE DIMENSIONS UNIT MODEL A B C Weight (lbs) Skid Qty. GBT GBT GBT GBT GBT ACCESS DOOR DIMENSIONS GAS ACCESS DOOR AND FRAME FOR USE WITH PANEL MODEL A B C D GBT 18 GAD-5(S/L) 49 1/2 27 1/2 47 1/2 26 GBT 19/24 GAD-3(S/L) 55 1/2 27 1/2 53 1/2 26 GBT 25/30 GAD-6(S/L) 63-1/2 27 1/2 61-1/2 26 GBT 31/36 GAD-4(S/L) 70-1/2 27 1/2 68-1/2 26 CEILING MOUNT GBT FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. CAP KIT PART NUMBER Part Number Model Number Enclosure Size CAP-5 GBT18 46 X24 X11 CAP-6 GBT19/24 52"X24"X11" CAP-7 GBT25/30 60"X24"X11" CAP-8 GBT31/36 67"X24"X11" Note: CAP kit is an insulated panel that covers the entire bottom opening and is utilized for optional ducted return configuration Atascocita Rd Humble, TX Phone Fax

51 CEILING MOUNT GES GES SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA HIGH EFFICIENCY ECM UNCASED CEILING MOUNT ELECTRIC HEAT DX COOL AIR HANDLER Product Dimensions & Specifications Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. STANDARD FEATURES APPLICATION VERSATILITY Built in mounting tabs for ceiling or furrdown mounting. Louvered ceiling access panel has separate frame that attaches to ceiling joists. Solid access panel available for use with end return installations. Compatible with most brands of air conditioners or heat pumps. Constant torque ECM allows motor speed control with embedded software. Motors are pre-programmed at the factory. ELECTRIC HEAT KITS Heat kits available in 3, 5, 6, 8 & 10 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Heat elements are replaceable without removing blowers. Easily accessible controls for quick service. Disconnect does not protrude through the wall panel. ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. DX COIL High efficiency rifled copper tube/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs is also available. Primary & secondary condensate drain. All drain connections are ¾ MPT. Powder-painted metal drain pan. Access door allows for coil cleaning. Certified for use with either R22 or R410A. Rev. Date: 03/28/ AirMark 1 50

52 MODEL GES 18/19/20 GES 24/25/26/27/28 GES 30/31/32 GES 36/37 HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA HEAT KIT NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING KW HEATING KBTUH MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V HTS HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS CEILING MOUNT GES AIR HANDLER CHASSIS NOMENCLATURE G E S 18 G -001 Voltage & Motor Configuration Option Code E = 240V Constant Torque ECM S = Uncased Ceiling Mount AirMark Air Handler Nominal Tonnage (KBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV ELECTRIC HEAT KIT NOMENCLATURE H T S 10 H = Fits GAS, GAT, GES, GET T = Terminal Block S = Small Cabinet (18-37) Heat Strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 06 = 6 KW 08 = 8 KW 10 = 10 KW 2 51

53 CEILING MOUNT GES UNIT MODEL GES 18/19 GES 20/24 GES 25 GES 26/30 GES 28 GES 31/36 GES 32 GES 37 SPEED TAP AMPS HIGH 0.9 HP BLOWER DATA CFM VS. STATIC PRESSURE MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW /2 HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 0.05 static when enclosure and/or ceilling panel are used. CHASSIS DIMENSIONS UNIT MODEL A B C Weight (lbs) Skid Qty. GES 18/19/ /4 34-5/ GES 20/ /4 40-5/ GES 26/30/31/ /4 46 5/ GES 28/32/ /4 53 5/

54 Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. FOR USE WITH ACCESS DOOR DIMENSIONS PANEL MODEL GAS ACCESS DOOR AND FRAME A B C D GES 18/19/24 GAD-1(S/L) 43-1/2 27-1/2 41-1/2 26 GES 20/25 GAD-5(S/L) 49-1/2 27-1/2 47-1/2 26 GES 26/30/31/36 GAD-2(S/L) 55-1/2 27-1/2 53-1/2 26 GES 28/32/37 GAD-6(S/L) 63-1/2 27-1/2 61-1/2 26 CEILING MOUNT GES 373 Atascocita Rd Humble, TX Phone Fax

55 CEILING MOUNT GET GET SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA HIGH EFFICIENCY ECM CASED CEILING MOUNT ELECTRIC HEAT DX COOL AIR HANDLER Product Dimensions & Specifications STANDARD FEATURES Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. APPLICATION VERSATILITY Built in mounting tabs for ceiling or furrdown mounting. Louvered ceiling access panel has separate frame that attaches to ceiling joists. Solid access panel available for use with end return installations. Compatible with most brands of air conditioners or heat pumps. Constant torque ECM allows motor speed control with embedded software. Motors are pre-programmed at the factory. LOW LEAKAGE CABINET Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to Airmark installation instructions. Sturdy, fully insulated galvanized steel cabinet with knockout for duct return. ELECTRIC HEAT KITS Heat kits available in 3, 5, 6, 8, & 10 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Easily accessible controls for quick service. DX COIL High efficiency rifled copper tube/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs is also available. Primary & secondary condensate drain. All drain connections are ¾ NPT. Powder-painted metal drain pan. Access door allows for coil cleaning. Certified for use with either R22 or R410A. ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. Rev. Date: 08/11/ AirMark 1 54

56 MODEL GET 18/19/20 GET 24/25/26/27/28 GET 30/31/32 GET 36/37 HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA HEAT KIT NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING KW HEATING KBTUH MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V HTS HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS HTS HTS HTS ,000 HTS HTS HTS CEILING MOUNT GET AIR HANDLER CHASSIS NOMENCLATURE G E T 18 G -001 Voltage & Motor Configuration Option Code E = 240V Constant Torque ECM S = Uncased Ceiling Mount AirMark Air Handler Nominal Tonnage (KBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV ELECTRIC HEAT KIT NOMENCLATURE H T S 10 H = Fits GAS, GAT, GES, GET T = Terminal Block S = Small Cabinet (18-37) Heat Strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 06 = 6 KW 08 = 8 KW 10 = 10 KW 2 55

57 CEILING MOUNT GET UNIT MODEL GET 18/19 GET 20/24 GET 25 GET 26/30 GET 28 GET 31/36 GET 32 GET 37 BLOWER DATA SPEED CFM VS. STATIC PRESSURE TAP AMPS HP HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW /2 HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 0.05 static when enclosure and/or ceiling panel are used. ENCLOSURES DIMENSIONS UNIT MODEL A B C Weight (lbs) Skid Qty. GET 18/19/ GET 20/ GET 26/30/31/ GET 28/32/ KNOCKOUT FOR DUCTED RETURN (Ducted return requires remote filter grille (field supplied) and non-louvered panel) 3 56

58 Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. ACCESS DOOR DIMENSIONS AND SPECIFICATIONS FOR USE WITH PANEL MODEL GAS ACCESS DOOR AND FRAME A B C D GET 18/19/24 GAD-1(S/L) 43-1/2 27-1/2 41-1/2 26 GET 20/25 GAD-5(S/L) 49-1/2 27-1/2 47-1/2 26 GET 26/30/31/36 GAD-2(S/L) 55-1/2 27-1/2 53-1/2 26 GET 28/32/37 GAD-6(S/L) 63-1/2 27-1/2 61-1/2 26 CAP KIT PART NUMBER Part Number Model Number Enclosure Size CAP-1 GET18/19/24 40"X24"X11" CAP-2 GET20/25 46"X24"X11" CAP-3 GET 26/30/31/36 52"X24"X11" CAP-4 GET 28/32/37 60"X24"X11" Note: CAP kit is an insulated panel that covers the entire bottom opening and is utilized for optional ducted return configuration CEILING MOUNT GET 373 Atascocita Rd Humble, TX Phone Fax

59 CEILING MOUNT GFS GFS SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA UNCASED CEILING MOUNT HYDRONIC HEAT HIGH EFFICIENCY ECM DX COIL AIR HANDLER Product Dimensions & Specifications Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 10/26/ AirMark STANDARD FEATURES Factory installed service switch Factory installed freeze protection Rifled copper tube/enhanced aluminum fins DX and hydronic coils for more efficient heat transfer Schrader valve on DX and hydronic coils for hisstest leak check Low leak cabinet design* APPLICATION VERSATILITY Built-in mounting tabs for ceiling or furdown mounting. Compatible with most brands of air conditioners and heat pumps. Optional louvered ceiling access panel has separate frame that attached to ceiling joists. Optional solid ceiling panel available for use with ducted return. Less than 2% air leakage (* when tested in accordance with ASHRAE standard 193 and AirMark installation instructions.) Constant torque ECM speeds and torques are controlled by embedded motor software and factory preprogrammed. Direct drive blowers circulate air quietly and efficiently. Air moving system is plated mounted to allow for easy removal and service. 1 ELECTRONIC CONTROLS Electronic board controls the functioning of system, increasing system reliability. Standard factory installed freeze stat wired into circulating pump control circuit. Standard factory installed fan time delay relay for increased efficiency and maximize capacity. Standard factory installed pump cycle timer circulates hot water every four hours to prevent coil freeze during off-cycle. DX/HYDRONIC COILS High efficiency rifled copper tube and enhanced aluminum fins provide maximum heat transfer. All coils are immersion tested at 500 PSI and nitrogen charged for maximum reliability. Schrader valve allows for hiss-test pre-installation pressure test. Available with factory installed orifice or TXV. Primary and secondary DX condensate drain with ¾ NPT connections. Powder-painted galvanized drain pan. Certified for use with R22 or R410A. Lead free construction. 58

60 MODEL HEATING AND COOLING PERFORMANCE & ELECTRICAL DATA NOMINAL COOLING (BTUS) GFS 18 18,000 GFS 19/24 24,000 GFS 25 24,000 GFS 30 30,000 GFS 31/36 36,000 BLOWER DATA CFM VS. STATIC PRESSURE UNIT MODEL RPM AMP VOLT HP HIGH GFS18 MED / LOW HIGH GFS19/24 MED / LOW HIGH GFS25 MED / LOW HIGH GFS30 MED / LOW HIGH GFS31/36 MED /2(2) LOW Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 0.05 static when enclosure and/or ceiling panel are used. GFS 31 and GFS 36 have two motors and four blowers. PERFORMANCE DATA PRESS. BTU (1000) AT ENTERING WATER TEMPERATURE F HEATING DROP GPM (FT. WTR) NOTES: Heat BTUH is at 70 degree EAT. 120 degree and 180 degree data is supplied for boiler applications. Heat BTUH output will not exceed output of water heater. CEILING MOUNT GFS AIR HANDLER CHASSIS NOMENCLATURE G F S 18 G -001 AirMark Air Handler F=120V Constant Torque ECM Motor Configuration S= Uncased Ceiling Mount Nominal Tonnage (KBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code 2 59

61 CEILING MOUNT GFS HYDRONIC HEAT KIT NOMENCLATURE Z T 2 S P Water Heat Hydronic Terminal Block 2 = 2 Row Hydronic Coil PHYSICAL DIMENSIONS GFS 18 - X GFS 19/24 - S GFS - 25/30 - M GFS 31/36 - L UNIT MODEL A B C D Weight (lbs) Skid Qty. GFS GFS GFS GFS GFS P = Taco 006 Bronze Pump 8 = Taco 008 Bronze Pump L = Less Pump Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. FILTER 20 x 20 x 1 field supplied. (GFS 18-30) (GFS 31-36) ACCESS DOOR DIMENSIONS GAS ACCESS DOOR AND FRAME FOR USE WITH PANEL MODEL A B C D GFS 18 GAD-5(S/L) 49 1/2 27 1/2 47 1/2 26 GFS 19/24 GAD-3(S/L) 55 1/2 27 1/2 53 1/2 26 GFS 25/30 GAD-6(S/L) 63-1/2 27 1/2 61-1/2 26 GFS 31/36 GAD-4(S/L) 70-1/2 27 1/2 68-1/2 26 WARRANTY One-year limited parts warranty Atascocita Rd Humble, TX Phone Fax

62 GFT SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA CASED CEILING MOUNT HYDRONIC HEAT HIGH EFFICIENCY ECM DX COIL AIR HANDLER Product Dimensions & Specifications CEILING MOUNT GFT Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 10/27/ AirMark STANDARD FEATURES Factory installed service switch Factory installed freeze protection Rifled copper tube/enhanced aluminum fins DX and hydronic coils for more efficient heat transfer Schrader valve on DX and hydronic coils for hisstest leak check Low leak cabinet design* APPLICATION VERSATILITY Built-in mounting tabs for ceiling or furdown mounting. Compatible with most brands of air conditioners and heat pumps. Optional louvered ceiling access panel has separate frame that attached to ceiling joists. Optional solid ceiling panel available for use with ducted return. Less than 2% air leakage (* when tested in accordance with ASHRAE standard 193 and AirMark installation instructions.) Fully insulated galvanized steel cabinet with knockout for ducted return. Constant torque ECM speeds and torques are controlled by embedded motor software and factory preprogrammed. Direct drive blowers circulate air quietly and efficiently. Air moving system is plated mounted to allow for easy removal and service. 1 ELECTRONIC CONTROLS Electronic board controls the functioning of system, increasing system reliability. Standard factory installed freeze stat wired into circulating pump control circuit. Standard factory installed fan time delay relay for increased efficiency and maximize capacity. Standard factory installed pump cycle timer circulates hot water every four hours to prevent coil freeze during off-cycle. DX/HYDRONIC COILS High efficiency rifled copper tube and enhanced aluminum fins provide maximum heat transfer. All coils are immersion tested at 500 PSI and nitrogen charged for maximum reliability. Schrader valve allows for hiss-test pre-installation pressure test. Available with factory installed orifice or TXV. Primary and secondary DX condensate drain with ¾ NPT connections. Powder-painted galvanized drain pan. Certified for use with R22 or R410A. Lead free construction. 61

63 CEILING MOUNT GFT HEATING AND COOLING PERFORMANCE & ELECTRICAL DATA PERFORMANCE DATA MODEL NOMINAL PRESS. BTU (1000) AT ENTERING WATER TEMPERATURE F HEATING COOLING DROP GPM (BTUS) (FT. WTR) GFT 18 18, GFT 19/24 24, GFT 25 24, GFT 30 30, GFT 31/36 36, NOTES: Heat BTUH is at 70 degree EAT. 120 degree and 180 degree data is supplied for boiler applications. Heat BTUH output will not exceed output of water heater. BLOWER DATA CFM VS. STATIC PRESSURE UNIT MODEL RPM AMP VOLT HP HIGH GFT18 MED / LOW HIGH GFT19/24 MED / LOW HIGH GFT25 MED / LOW HIGH GFT30 MED / LOW HIGH GFT31/36 MED /2(2) LOW Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 0.05 static when enclosure and/or ceiling panel are used. GFT 31 and GFT 36 have two motors and four blowers. AIR HANDLER CHASSIS NOMENCLATURE G F T 18 G -001 AirMark Air Handler F=120V Constant Torque ECM Motor Configuration T = Cased Ceiling Mount Nominal Tonnage (KBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code 2 62

64 Airflow Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. HYDRONIC HEAT KIT NOMENCLATURE Z T 2 S P Water Heat Hydronic Terminal Block 2 = 2 Row Hydronic Coil FOR USE WITH GFT 18 - X GFT 19/24 - S GFT - 25/30 - M GFT 31/36 - L ENCLOSURE DIMENSIONS ACCESS DOOR DIMENSIONS PANEL MODEL P = Taco 006 Bronze Pump 8 = Taco 008 Bronze Pump L = Less Pump UNIT MODEL A B C Weight (lbs) Skid Qty. GFT GFT GFT GFT GAS ACCESS DOOR AND FRAME A B C D GFT 18 GAD-5(S/L) 49 1/2 27 1/2 47 1/2 26 GFT 19/24 GAD-3(S/L) 55 1/2 27 1/2 53 1/2 26 CEILING MOUNT GFT MATERIALS Galvanized steel construction with smooth powder paint finish. GFT 25/30 GAD-6(S/L) 63-1/2 27 1/2 61-1/2 26 GFT 31/36 GAD-4(S/L) 70-1/2 27 1/2 68-1/2 26 FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. CAP KIT PART NUMBER Part Number Model Number Enclosure Size CAP-5 GFT18 46 X24 X11 CAP-6 GFT19/24 52"X24"X11" CAP-7 GFT25/30 60"X24"X11" CAP-8 GFT31/36 67"X24"X11" Note: CAP kit is an insulated panel that covers the entire bottom opening and is utilized for optional ducted return configuration Atascocita Rd Humble, TX Phone Fax

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 Due to continuous product improvement, specifications are

More information

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER MODEL (INCLUDING HEATER MODEL #) SERIAL # INSTALLER INSTALLATION DATE These instructions should

More information

PRODUCT CATALOG. Aspen Manufacturing - Evaporator coils - Air Handlers - Manufactured Home Products - Light Commercial Coils

PRODUCT CATALOG. Aspen Manufacturing - Evaporator coils - Air Handlers - Manufactured Home Products - Light Commercial Coils PRODUCT CATALOG Aspen Manufacturing - Evaporator coils - Air Handlers - Manufactured Home Products - Light Commercial Coils Aspen Background: Aspen, headquartered in Humble, Texas, is one of the largest

More information

PRODUCT CATALOG. Aspen Manufacturing - Evaporator coils - Air Handlers - Manufactured Home Products - Light Commercial Coils

PRODUCT CATALOG. Aspen Manufacturing - Evaporator coils - Air Handlers - Manufactured Home Products - Light Commercial Coils PRODUCT CATALOG Aspen Manufacturing - Evaporator coils - Air Handlers - Manufactured Home Products - Light Commercial Coils Aspen Background: Aspen, headquartered in Humble, Texas, is one of the largest

More information

AIR HANDLERS AIR HANDLERS

AIR HANDLERS AIR HANDLERS FORM NO. H11-33 REV. 1 Supersedes Form No. H11-33 AIR HANDLERS AIR HANDLERS RHBL- Efficiency X-13 (ECM) featuring Industry Standard R-410A Refrigerant RHAL- Standard Efficiency PSC featuring Industry Standard

More information

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Rheem Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check

More information

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Ruud Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check

More information

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Rheem Air Handler RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RHAL- Series PSC Motor Efficiencies up to 14. SEER Front or Bottom Return Flow Check Piston for cooling or heat pump

More information

PARTS LISTS GAS/T... 1 GAW... 3 GBS/T... 5 GES/T... 6 GFS/T... 8 GFW... 9

PARTS LISTS GAS/T... 1 GAW... 3 GBS/T... 5 GES/T... 6 GFS/T... 8 GFW... 9 PARTS LISTS GAS/T... 1 GAW... 3 GBS/T... 5 GES/T... 6 GFS/T... 8 GFW... 9 Revised 12/01/17. APK Manufacturing reserves the right to make changes at any time without notice and without incurring any obligation.

More information

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW ADPF THREE-SPEED AIR HANDLER The ADPF Dedicated Downfl ow Three-Speed Air Handler is suitable for use with refrigerants R-410A and R-22. The unit features a check flowrater expansion device and may be

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access

More information

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7 Multi-Position, Variable-Speed Air Handlers 1½ to 5 Tons Standard Features Suitable for use with R-410A and R-22 refrigerants Check flowrater expansion device for cooling and heat pump applications Variable-speed

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile

More information

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

DEDICATED VERTICAL/WALL MOUNT

DEDICATED VERTICAL/WALL MOUNT WCW-Chilled Water Cooling Electric or Hot Water Heating Description: The B/S/H, & WCW air handlers with electric or hot water heating are designed for recessed mounting in a wall, hanging on the wall,

More information

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay. Description: These air handlers are designed for horizontal mounting into a furred down ceiling, and will handle up to 1150 CFM and up to 3 ton of cooling with a DX cooling or heat pump coil, or Chilled

More information

AVPTC. Air Handlers 1½ to 5 Tons

AVPTC. Air Handlers 1½ to 5 Tons Multi-Position, Variable-Speed Air Handlers ½ to Tons Standard Features Compatible with the ComfortNet Communicating System family of products R-0A refrigerant-compatible Factory-installed thermal expansion

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

TECHNICAL SPECIFICATIONS B6VMMX

TECHNICAL SPECIFICATIONS B6VMMX TECHNICAL SPECIFICATIONS BVMM Series Air Handler with TV, -, Btuh (Heat Pump & Air Conditioner) R-4A Refrigerant The BVMM Series of air handlers, when combined with our heat pump or air conditioner, offers

More information

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting track for quick repositioning Optimized for

More information

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat SG-MAH-08 April 2016 MX Series Indoor Modular Blowers Electric Heat, Hot Heat, or No Heat Specification Guide Contents...Pa Page Standard Features... 2 Physical Data... 2 Blower Performance... 3 Nomenclature...

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor ComfortNet Communicating System compatible Auto configuration

More information

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Rheem High Efficiency Modulating EcoNet Enabled Air Handler Air Handlers Series Rheem High Efficiency Modulating EcoNet Enabled Air Handler - Series Constant CFM (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 20.5 SEER The is EcoNet Enabled: This allows

More information

CWA4 Chilled & Hot Water Fan Coil

CWA4 Chilled & Hot Water Fan Coil CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000

More information

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3 FORM NO. H66- REV. 1 Supersedes Form No. G66-6 Rev. WH1T SERIES Constant Torque (ECM) Efficiencies up to 1 SEER HIGH EFFICIENCY AIR HANDLER Features WH1T feature a Constant Torque motor (ECM) which provides

More information

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor Contents Nomenclature... 2 Accessories... 2... 3 Dimensions... 4 Airflow Data... 5 Heat Kit Data... 6 Wiring Diagram... 8 Series Product Features Internal factory-installed thermal expansion valves for

More information

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor Air Handlers Rheem Air Handlers RHML- Series X-13 (ECM) RHML feature GE s new X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 2 ton [7.0 kw] through 5 ton [17.6

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 Check flowrater for heat pump and cooling-only applications All-aluminun tube/aluminum

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows the RHT to directly communicate

More information

Bosch BVA Series Air Handler

Bosch BVA Series Air Handler Bosch BVA Series Air Handler 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BVA Product Specifications Data subject to change 12.2016 Bosch Thermotechnology Corp. Product Specifications

More information

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows

More information

INSTALLATION GUIDE. GFT/GFS Series - Cased/Uncased Ceiling Mount Hydronic Heat Dx Cool Air Handler ! WARNING. 1. Safety Instruction. 2.

INSTALLATION GUIDE. GFT/GFS Series - Cased/Uncased Ceiling Mount Hydronic Heat Dx Cool Air Handler ! WARNING. 1. Safety Instruction. 2. 1. Safety Instruction INSTALLATION GUIDE GFT/GFS Series - Cased/Uncased Ceiling Mount Hydronic Heat Dx Cool Air Handler Potential safety hazards are alerted using the following symbols. The symbol is used

More information

INSTALLATION AND OWNERS MANUAL

INSTALLATION AND OWNERS MANUAL INSTALLATION AND OWNERS MANUAL SINGLE PIECE AIR HANDLER DX and Chilled Water Cooling / and Hot Water Heating CONTENTS: Unit Nomenclature... General Information Inspection.. Reference... Limitations Location.

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18B1000A 2/4TEC3F24B1000A 2/4TEC3F30B1000A 2/4TEC3F36B1000A 2/4TEC3F42C1000A 2/4TEC3F48B1000A 2/4TEC3F55B1000A 2/4TEC3F60B1000A 1½ 5 Ton PUB. NO. 22-1774-17

More information

INSTALLATION GUIDE. AAM and AEM Series - Multi-Position Air Handler (Electric Heat) ! WARNING ! CAUTION. 1. Safety Instruction. 2.

INSTALLATION GUIDE. AAM and AEM Series - Multi-Position Air Handler (Electric Heat) ! WARNING ! CAUTION. 1. Safety Instruction. 2. INSTALLATION GUIDE AAM and AEM Series - Multi-Position Air Handler (Electric Heat) 1. Safety Instruction Potential safety hazards are alerted using the following symbols. The symbol is used in conjunction

More information

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES TP TECH GUIDE TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP 1200-2000 CFM BLOWERS 3-5 TON COILS OPTIONAL ELECTRIC HEATERS ISO 9001 Certified

More information

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER FORM NO. HFJ-6 Supersedes Form No. PTZ-789 HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER Features The FH**TTT is EcoNet Enabled: This allows the FH**TTT to directly communicate with the EcoNet Smart

More information

INSTALLATION GUIDE. AFM Series - Multi-Position Air Handler (Hydronic Heat) 1. Safety Instruction. 2. Introduction !

INSTALLATION GUIDE. AFM Series - Multi-Position Air Handler (Hydronic Heat) 1. Safety Instruction. 2. Introduction ! INSTALLATION GUIDE AFM Series - Multi-Position Air Handler (Hydronic Heat) 1. Safety Instruction Potential safety hazards are alerted using the following symbols. The symbol is used in conjunction with

More information

Rheem Standard Efficiency Air Handler

Rheem Standard Efficiency Air Handler Air Handlers Rheem Standard Efficiency Air Handler RHSL- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...

More information

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS OPTIONAL ACCESSORIES Two Row Hot Water Coil MAGIC AIRE DH SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED

More information

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features Series Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ-544 Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER FB***TS SERIES X-13 (ECM) Motor Efficiencies up to 16 SEER Features Industry Standard R-410A Refrigerant also Suitable for R-22

More information

Upflow/Downflow A-Coil Specifications

Upflow/Downflow A-Coil Specifications June 2013 Upflow/Downflow A-Coil Specifications ADP Model # Width Depth Height Pallet Qty. Coil Weight (lbs) C36A142(*)126 14.25" 21" 16.5" 12 38 1200 386.36 C36A175(*)126 17.50" 21" 16.5" 8 40 1200 386.34

More information

Modular Multi-position Air Handler

Modular Multi-position Air Handler Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design

More information

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat Kit Data...6 Wiring Diagram... Accessories... Product Features Internal factory-installed thermal

More information

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE NOW AVAILABLE WITH AUTOSPEED V CONTROL Product Specifications MB Series MBE Series W Series Vertical / Horizontal Direct Drive Hydronic Fan Coils 00 0 CFM NEW OPTION AVAILABLE: AUTOSPEED V CONTROL PACKAGE

More information

Bosch BVA Series Air Handler

Bosch BVA Series Air Handler Bosch BVA Series Air Handler --- Ton Capacity R0A Product Specifications Product Specifications BVA Series Air Handler --- Ton Capacity R0A Air Handler Features Multi-speed ECM blower motor. Factory-installed

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat

More information

WAHL A Product Specifications

WAHL A Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Number Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,

More information

FEM4X. Product Specifications FAN COILS /14/15

FEM4X. Product Specifications FAN COILS /14/15 ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS 1 1/2 thru 5 tons Available for environmentally sound R 410A systems Factory installed TXV metering device Sweat connections Aluminum Tube, Aluminum Fin Evaporator

More information

AVPTC. Air Handler 1½ to 5 Tons

AVPTC. Air Handler 1½ to 5 Tons Multi-Position, Variable-Speed Air Handler ½ to 5 Tons Standard Features Compatible with the ComfortNet Communicating System family of products Maximum four low-voltage wires required for operation in

More information

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons ASUF Series Multi-Position Multi-Speed ECM Based Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting

More information

INSTALLATION GUIDE. AEC & AAC Series - Ceiling Mount Air Handler (Electric Heat) 1. Safety Instruction. 2. Introduction !

INSTALLATION GUIDE. AEC & AAC Series - Ceiling Mount Air Handler (Electric Heat) 1. Safety Instruction. 2. Introduction ! INSTALLATION GUIDE AEC & AAC Series - Ceiling Mount Air Handler (Electric Heat) 1. Safety Instruction Potential safety hazards are alerted using the following symbols. The symbol is used in conjunction

More information

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and

More information

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years DUW/DUX SERIES 1.5 THROUGH 5 TON VERTICAL OR HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Vertical, Horizontal (Left

More information

GFM SERIES INSTALLATION & OPERATING INSTRUCTIONS HIGH EFFICIENCY X13 MULTI-POSITION AIR HANDLER (HYDRONIC HEAT)

GFM SERIES INSTALLATION & OPERATING INSTRUCTIONS HIGH EFFICIENCY X13 MULTI-POSITION AIR HANDLER (HYDRONIC HEAT) GFM SERIES INSTALLATION & OPERATING INSTRUCTIONS HIGH EFFICIENCY X13 MULTI-POSITION AIR HANDLER (HYDRONIC HEAT) MODEL (INCLUDING HEATER MODEL #) SERIAL # INSTALLER INSTALLATION DATE These instructions

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEH3F18B1000A 2/4TEH3F24B1000A 2/4TEH3F30B1000A 2/4TEH3F36B1000A 2/4TEH3F42C1000A 2/4TEH3F48B1000A 2/4TEH3F60B1000A 1½ 5 Ton PUB. NO. 22-1777-10 Features and

More information

Hydronic Air Handler Powered by Tankless Technology

Hydronic Air Handler Powered by Tankless Technology Integrated Solutions Hydronic Air Handler Powered by Tankless Technology RW1P/RW1T- Series Nominal Heating Capacities: 40-100 kbtu [11.7-29.3 kw] Tankless Water Heater Models: RTG-64DVL indoor direct vent

More information

Vertical Upflow Horizontal Left Air Handlers

Vertical Upflow Horizontal Left Air Handlers Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with

More information

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3

More information

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A4018-24C/30-060B 2009 American Standard Heating & Air Conditioning PUB.. 12-1173-04 April 2009 Features and Benefits Duration compressor Efficiency

More information

Condensing Units & Air Handlers

Condensing Units & Air Handlers Condensing Units & Air Handlers 13 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice. Copyright

More information

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons ACNF Series Ceiling-Mounted Air Handlers 1½ to 2½ Tons Contents Nomenclature...2 Heat Kit Data...2 Product Specifications...3 Dimensions...5 Airflow Data...5 Wiring Diagram...6 Accessories...8 Features

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5

More information

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE

More information

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H3018-060A 2008 American Standard Heating & Air Conditioning PUB. NO. 12-1216-02 June 2008 Features and Benefits Duration compressor Efficiency up

More information

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering device

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

INSTALLATION GUIDE. GBT/GBS Series - Cased/Uncased Ceiling Mount Hydronic Heat Dx Cool Air Handler ! WARNING. 1. Safety Instruction

INSTALLATION GUIDE. GBT/GBS Series - Cased/Uncased Ceiling Mount Hydronic Heat Dx Cool Air Handler ! WARNING. 1. Safety Instruction 1. Safety Instruction INSTALLATION GUIDE GBT/GBS Series - Cased/Uncased Ceiling Mount Hydronic Heat Dx Cool Air Handler Potential safety hazards are alerted using the following symbols. The symbol is used

More information

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105) TECHNICAL GUIDE VARIALE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: N1VS 600-2000 CFM LOWERS 2-5 TON COILS OPTIONAL 1 & 3 φ ELECTRIC HEATERS ISO 9001 Certified Quality Management

More information

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE NOW AVAILABLE WITH AUTOSPEED V CONTROL Product Specifications MB Series MBE Series W Series Vertical / Horizontal Direct Drive Hydronic Fan Coils 0 CFM NEW OPTION AVAILABLE: AUTOSPEED V CONTROL PACKAGE

More information

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton AEPT SERIES Multi-Position Air Handler 2 to 5 Ton The AEPT multi-position air handler is approved for modular homes and may be installed in a utility room, closet, aclove, basement or attic. Standard Features

More information

CB X 32 mv

CB X 32 mv PRODUCT SPECIFICATIONS AIR HANDLERS CBXMV DAVE LENNOX SIGNATURE COLLECTION R-0A Ready - Multi-Position - Variable Speed Bulletin No. 0 October 0 Supersedes July 0 Nominal Capacity -. to + Tons Optional

More information

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25

More information

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

GBW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (HYDRONIC HEAT)

GBW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (HYDRONIC HEAT) GBW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (HYDRONIC HEAT) MODEL (INCLUDING HEATER MODEL #) SERIAL # INSTALLER INSTALLATION DATE These instructions should be retained

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

INSTALLATION GUIDE. GAT & GAS Series - Horizontal Ceiling Mount Electric Heat Dx Cool Air Handler ! WARNING ! CAUTION. 1. Safety Instruction

INSTALLATION GUIDE. GAT & GAS Series - Horizontal Ceiling Mount Electric Heat Dx Cool Air Handler ! WARNING ! CAUTION. 1. Safety Instruction INSTALLATION GUIDE GAT & GAS Series - Horizontal Ceiling Mount Electric Heat Dx Cool Air Handler 1. Safety Instruction Potential safety hazards are alerted using the following symbols. The symbol is used

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...

More information

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK

More information

GAW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (ELECTRIC HEAT)

GAW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (ELECTRIC HEAT) GAW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (ELECTRIC HEAT) MODEL (INCLUDING HEATER MODEL #) SERIAL # INSTALLER INSTALLATION DATE These instructions should be retained

More information

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil Specification 2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,

More information