HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

Size: px
Start display at page:

Download "HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION"

Transcription

1 E L E CT R I C DUCT HEATER FLIPPABLE EK SERIES SHOWN RH SERIES RH-W SHOWN RENEWAIRE ERV + ELECTRIC DUCT HEATER: A SINGLE-SOURCE SOLUTION RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

2 RH SERIES ELECTRIC DUCT HEATER RH-D (Integral Thermostat) NEW Electric Dct Heater ( kw) Accessory SPECIFICATIONS Heater Type: Electric Dct Heater Typical KW Range: kw (1, 2, 3, 4, 5, 6, 8, 10, 11.5 kw) Voltages & Phase: Single phase - 120, 208 and 240V Control Voltage: 24 VAC Standard Featres: Open-coil element High grade nickel-chrome element wire Thermostat - Integral (RH-D), Wall mont (RH-W) Modlating heat otpt (SCR control) Vertical or horizontal operation Atomatic limit switch for primary Manal reset limit switch for secondary Airfl ow sensor Standard control transformer - 24 VAC Corrosion resistant galvanized steel Rond dct collars High voltage terminal block connections Gronding lg Monting fl anges LR Note: Electric dct designed for indoor dctwork installation only. Dct Collars kw V Size Width (X) Height (Y) Depth (Z) 6" 1, 2 120, 208, 240 A 11 1/2" 8" 11 1/2" 8" 3, 4, B 11 1/2" 10" 13 1/2" 8" 3, 4, 5, B 11 1/2" 10" 13 1/2" 10" 3, 4, B 11 1/2" 10" 13 1/2" 10" 3, 4, 5, B 11 1/2" 10" 13 1/2" RH-W (Wall Mont Thermostat) 10" 8, 10, C 15 1/2" 12" 15 1/2" 12" 6, 8, 10, C 15 1/2" 12" 15 1/2" Download specification at: renewaire.com/specifications Y Z X A B C DIMENSIONS IN INCHES SIZE X Y Z A B C Minimm Airflow (CFM) Heater Capacity (kw) HEATER CAPACITY - kw RH SERIES HEATER CAPACITY SAFE OPERATING RANGE AIRFLOW - CFM Specifi cations may be sbject to change withot notice. 2

3 E L E C T R I C D U C T H E AT E R ( K W ) RenewAire offers the highest-efficiency Energy Recovery Ventilators (ERVs) on the market. However, dring winter conditions, spply air from the ERV may be less than optimal for space conditions. By adding C O N F I G U R A B L E E L E C T R I C D U C T H E AT E R S as an option to or commercial ERVs, RenewAire can now heat spply air dring cooler months to enhance indoor comfort, all via one package for ERVs and s from a single sorce. KEY BENEFITS S T A N D A R D F E AT U R E S pen-coil element with slip-in O mont installation A irflow switch D ct stat and dct sensor isconnect switch, control terminal D board and transformer Power fsing over 48 amps inclded G ronding lgs L eft-hand offset control box A disconnecting magnetic control contactor per stage or each 48-amp circit within a stage A tomatic limit switch for primary anal reset limit switch for secondary M T he wire rack element sspension system allows for a low-pressre drop across the coils with its aerodynamic design I n horizontal applications, airflow can travel in either direction withot any modification, allowing for easy field modifications ontrol-box featres hinge and latch C for easy access OPTIONS AND ACCESSORIES A single-sorce responsibility redces time and costs: A single information sorce, a single prchase point and a single approval package for ERVs and s redces design time and costs, and streamlines logistics for design engineers and contractors. E asy installation: A ZERO clearance rating to combstibles allows designers and contractors to apply RenewAire s with less restrictions onsite. E LECTRONIC STEP CONTROLLER Provides electronic seqencing control of an electric dct p to 4 steps. When interrption of power occrs, all the stages will recycle to off. Upon the restoration of power, re-energize the switches in a stepping seqence. Commonly sed with a 2 10 vdc from a stand-alone T-stat, 2-10 vdc from a DDC bilding atomation system and 4-20 ma from a bilding atomation system. P ILOT LIGHTS H ighly certified: UL Listed (UL1996 Standard) and CSA certified. Side-panel installation for indicating is energized. Control voltages are available as 24 or 120 volts. S CR CONTROLS INSTALLATION SCRs MANUAL provide the finest in electric dct control with 100% step-less modlating INSTALLATION MANUAL control. Utilizes Solid State Relays (SSR) to switch crrent to the heating elements on a TUTCO time-proportioned basis. Heaters with SCR controls have internal thermal protection to TUTCO DUCT DUCT HEATERS HEATERS prevent overheating. A P P L I C AT I O N S RenewAire ERV and combinations can be applied anywhere ERVs are installed, with a focs on commercial and instittional bildings. However, VRF systems, hydronic panels and areas where non-dcted systems are applied offer an exclsive installation opportnity. RenewAire s can sit site restrictions in size, configration or orientation, and can be designed for preheat capabilities in certain extreme weather conditions. The information and instrctions in this sheet apply to Dct Heater The information and instrctions in this sheet apply to Dct Heater models for zero clearance installation in dcts. models for zero clearance installation in dcts. The Dct Heaters are approved for se with heat pmps, air The Dct Heaters are approved for se with air conditioners, or other forced air systems. Theyheat maypmps, be controlled by conditioners, or other forced air They may be controlled by contactors, relays, seqencers orsystems. solid state devices. contactors, relays, seqencers or solid state devices. The Dct Heaters are prewired, have voltage ratings to 600 volts, both The Dct Heaters are phase. prewired, have voltage ratings to 600 volts, both single phase and three single phase and three phase. The Dct Heaters are frnished with integral controls, except for the DD Heaters integral controls, except forfor the DD & The DHDDct series, whichare arefrnished frnishedwith with a separate control panel & DHDmonting. series, which are frnished with a separate control panel for remote remote monting. GENERAL: GENERAL: Inspect for any possible shipping damage. Check all inslators Other applications inclde existing installations that reqire additional heat, increased heat or simply replacement s. RenewAire s can be designed for 75 F comfort conditions, or warmer, and since ERV spply air is dcted into the space, tempering otdoor air for space conditions or offering spplemental heat is easy and simple. any possible shipping wire damage. Check all inslators forinspect breakage andfor inspect element for any deformation that for breakage and inspect element deformation that cold case a short circit or grond. Makewire sreforallany fasteners are tight. cold case a short circit or grond. sre all fasteners are tight. Electrical connections sch as pressremake terminals shold be checked for Electrical connections sch as pressre terminals shold be checked for tightness. tightness. INSTALLATION: INSTALLATION: For safe operation and best performance, the following installation For safe operation best to. performance, the following installation procedres mst be and adhered procedres mst be adhered to. Heaters may be installed in the sides of either horizontal or vertical Heaters may be installed in the sides of either horizontal or vertical dcts bt never in the top or bottom of a horizontal dct. Heaters dcts bt never in the top or bottom of a horizontal dct. Heaters installed in vertical dcts are tested and approved for p airflow only! installed in vertical dcts are tested and approved for p airflow only! C O N S T R U C T I O N A N D I N S T A L L AT I O N RenewAire s have been designed to match or existing prodct offering heat capacities that range from kw and the ability to handle airflows from ,000 CFM. Or s are factory-assembled and wired for the electrical specialties and controls of each project, and can be installed as a slip-in or flanged configration. The s are shipped loose, can be dct-installed onsite and are designed for post-installation if necessary. Heaters are wired with a separate power sorce to be placed anywhere downstream of the ERV orinstallation to be split to servemanual different areas with a single ERV. TUTCO DUCT HEATERS FLANGE INSTALLATION 1.Install a a minimm of (4) feet from heat pmps or central air The information and by instrctions in thisthe sheet applybetween to Dct Heater Installed connecting two sections 1.Install a a minimm of (4) feet from heat pmps or central air conditioners. models for zero clearance installation in dcts. conditioners. RenewAire s are for indoor se only. 2. At least 4 feet downstream from an air handler. 2. At least 4 feet downstream from an air handler least2 2feet feeteither eitherside sideofofan anelbow elboworortrn. trn. The Dct Heaters are approved for se with heat pmps, air conditioners, or other forced air systems. They may be controlled by DOUBLE contactors, relays, seqencers or solid state devices. LIP MODELS RenewAire EK s can be rotated 180, and are capable of vertical p/down airflow least4 4feet feetdownstream downstreamfrom froman anair airfilter. filter. Refer Refertotothe theback backofofthis thissheet sheetfor: for:dct, dct,electrical electricaland andair airvelocity velocity reqirements. reqirements. (FLIPPABLE) CAPACITY kw MIN. DUCT SIZE (H x W) 8" x 8" MAX. DUCT SIZE (H x W) 99" x 99" EK SERIES SCR HEAT SINKS CONTACTOR AIRFLOW FRAME FRAME GENERAL: ELEMENTS Interior shown CERAMIC MOUNTING COILS The Dct Heaters are frnished with integral controls, except for the DD & DHD series, which are frnished with a separate control panel for remote monting. Inspect for any possible shipping damage. Check all inslators for breakage and inspect element wire for any deformation that ToTo install installa aslip-in slip-in FIG.1, FIG.1,ct ctan anopening, opening,as asreqired reqiredininthe theside side cold case a short circit or grond. Make sre all fasteners are tight. ofof the thedct. dct.slide Slide ininthe thedct dctsing singcontrol controlbox boxas astemplate templatetoto Electrical connections sch as pressre terminals shold be checked for mark markthe themonting montingscrew screwholes. holes.remove Removenit nitand anddrill drillmonting montingholes. holes. tightness. Mont Montnit nittotodct dctwith withsheet sheetmetal metalscrews. screws.connect Connecthigh highand andlow low voltage voltagespplies sppliesalong alongwith withfan faninterlock interlockcircit circit(if(ifno noairflow airflowswitch switchisis INSTALLATION: frnished). HEATING frnished).larger Largers smay mayreqire reqirehangers. hangers. For safe operation and best performance, the following installation E K SE R I E S Installed by slipping the into a dctwork opening. of flanged dctwork The least4 4feet feetfrom fromany anycanvas canvasdct dctconnector connectororortransition transitionsection sectionfor for Dct Heaters are prewired, have voltage ratings to 600 volts, both change single phase and three phase. changeinindct dctsize. size least4 4feet feetpstream pstreamfrom froma ahmidifier. hmidifier. SLIP-IN INSTALLATION procedres mst be adhered to. ToTo install installa aflange flangetype type FIG.2, FIG.2,Insert Insert between betweentwo twosections sections TERMINAL OR ofof flanged flangeddct dctand andbolt boltininplace. place.for Foradditional additionalstrength, strength,the thedct dctflange flange Heaters may be installed in thecontrol sides of either horizontal or vertical BOX shold sholdbebedobled dobledasasshown shownininthe thefigre. figre.large Larges smay mayreqire reqire dcts bt never in the top or bottom of a horizontal dct. Heaters hanger hangerstraps. straps.connect Connecthigh highand andlow lowvoltage voltagespplies sppliesalong alongwith withfan fan installed in vertical dcts are tested and approved for p airflow only! interlock interlockcircit circit(if(ifnonoairflow airflowswitch switchisisfrnished). frnished). SCR FUSING DISCONNECT PILOT TRANSFORMER 1.Install a a minimm of (4) feet from heat pmps or central air CONTROL LIGHT conditioners. 2. At least 4 feet downstream from an air handler. INC. INC GOULD GOULDDRIVE DRIVE 3. At COOKEVILLE, COOKEVILLE, TN least 2 feet eithertn side38506 of an elbow or trn. FAX PHONE FAX(931) (931) PHONE (931) (931) At least 4 feet from any canvas dct connector or transition section for HEATING ELEMENTS TERMINAL OR CONTROL BOX

4 E L E C T R I C D U C T H E AT E R ( K W ) RenewAire offers the highest-efficiency ERVs on the market. However, dring winter S T A N D A R D F E AT U R E S conditions, spply air from the ERV may be less than optimal for space conditions. By adding O pen-coil element H igh-grade, nickel-chrome element wire W all-mont thermostat (wall mont only) R E N E W A I R E S R O U N D E L E C T R I C D U C T H E AT E R as an option to or residential and light commercial ERVs, RenewAire can now heat spply air dring cooler months to enhance indoor comfort, all via one package for ERVs and s H SERIES from a single sorce. KEY BENEFITS Vertical or horizontal operation Atomatic limit switch for primary M anal reset limit switch for secondary Temperatre (dct) sensor (dct mont only) Modlating heat otpt (SCR control) Airflow sensor S tandard control transformer 24 VAC C orrosion-resistant galvanized steel R ond dct collars H igh-voltage terminal block connections G ronding lg M onting flanges C O N S T R U C T I O N A N D I N S T A L L AT I O N A single sorce redces time and costs: A single information sorce, a single prchase point and a single approval package for ERVs and s redces design time and costs, and streamlines logistics for design engineers and contractors. E asy installation: A ZERO clearance rating to combstibles allows designers and contractors to apply RenewAire s with less restrictions onsite. H ighly certified: CSA certified and evalated to the applicable ANSI/UL and CSA Standards, for se in the U.S. and Canada. RenewAire RH series s complement RenewAire EK Series electric dct offering heat capacities that range from kw for rond-dct diameters from 6" to 12". They have the ability to handle airflows from 30 1,000 CFM. Each electric dct 's niqe design allows air to flow freely for the lowest possible pressre drop. Or s are factory-assembled and wired for the electrical specialties and controls of each project, and are available with rond dct connection collars. The s are shipped loose, can be dct-installed onsite and are designed for post-installation if necessary. Heaters are wired with a separate power sorce to be placed anywhere downstream of the ERV or to be split to serve different areas with a single ERV. A P P L I C AT I O N S RenewAire ERV and rond electric combinations can be applied anywhere residential and light commercial ERVs are installed with 6", 8", 10" and/or 12" rond dctwork. The varying kw sizes and single phase electric power offerings allow the rond electric s to be applied to sit any project s reqirements for spplemental electric heating. Other applications inclde existing installations that reqire additional heat, increased heat or simply replacement s. TRANSFORMER RH-D AUTOMATIC RESET AIRFLOW SENSOR CONTROL TERMINAL BLOCK RH-W (Integral Thermostat) AUTOMATIC RESET AIRFLOW SENSOR TRANSFORMER (Wall-Mont Thermostat) RenewAire s can be designed for 75 F comfort conditions, or warmer, and since ERV spply air is dcted into the space, tempering otdoor air for space conditions or offering spplemental heat is easy and simple. RenewAire s are for indoor se only. MODELS RenewAire s RH series single-phase rond electric dct are available in two models: RH-D and RH-W. In the RH-W model the temperatre control is wall monted in the room, while for the RH-D the temperatre controller is integral to the nit. R H SERIES CAPACITY kw MIN. DUCT COLLAR 6" MAX. DUCT COLLAR 12" ELECTRONIC CONTROLLER 5 MANUAL RESET POWER TERMINAL BLOCK SOLIDSTATE RELAY SOLIDSTATE CONTROLLER MANUAL RESET POWER TERMINAL BLOCK 6

5 EK SERIES Electric Dct Heater (1-175 kw) Accessory ELECTRIC DUCT HEATER Download specification at: renewaire.com/specifications SPECIFICATIONS Heater Type: Electric Dct Heater Typical KW Range: kw Standard Featres: A disconnecting magnetic control contactor per stage or each 48 Amp circit within a stage Open-coil element Staged on/off Control terminal board Gronding lgs Atomatic limit switch for primary overtemperatre protection Manal reset limit switch for secondary overtemperatre protection Non-adjstable airfl ow switch Standard control transformer - 24 VAC Disconnect switch Dct thermostat with sensor for on/off control (Ni/Cr/Fe) C Grade element wire with nickel-plated terminals Slip-in mont No left/right hand Vertical p/down fl ow Voltages & Phase: Single phase - 120, 208, 240, 277 Three phase - 208, 240, 480, 600 Control Voltage: 24 VAC Dimensions: Minimm - 8" x 8" (W x H) Maximm - 99" x 99" (W x H) Options: Flange mont (Ni/Cr) A Grade element wire with stainless steel terminals Recessed control box 1" Gasketed cover - dst tight Power fsing, standard for s drawing more than 48 Amps 2-stage Electronic step controller (4-stage) SCR (p to 96 Amps) SCR Vernier (over 96 Amps) Pilot light Accessory: Room thermostat Room/dct thermostat-sensor kit for SCR control Note: Electric dct designed for indoor dctwork installation only. HEATER CAPACITY - kw EK SERIES HEATER CAPACITY SAFE OPERATING RANGE Static Pressre Drop - Inches of Water PRESSURE DROP THROUGH HEATER AIRFLOW - CFM Air Velocity - FPM (1, 2, 3 and 4 - the nmber of rows of coils) When the nmber of rows of coils is nknown, assme 4. FLIPPABLE CAPABILITIES Uniqe to the EK series, this nit has the ability to flip 180. Additionally, EK s featre both vertical p and vertical down airflow. 7

6 EK SERIES DETERMINING MAXIMUM HEATER KW Maximm Watts per Sq. In. of Dct Area Dct width (inches) x dct height (inches) = dct watts total sq. in. Max W = X w x dct area in 2 in 2 RH SERIES For EK, X = w MINIMUM AIR VELOCITIES MINIMUM AIRFLOW AND AIR VELOCITIES Minimm Airflow (CFM) = 30 (CFM) x Heater Capacity (kw) Example: Heater Capacity = 4 kw 30 CFM x 4 kw = 120 CFM Minimm Airflow Minimm Velocity = Minimm Airflow (CFM) Rond Dct Area (ft 2 ) Example: Heater Capacity = 4 kw Area of 8" Rond Dct Size = ft CFM Minimm Airflow / sqare feet dct area = 344 FPM minimm cross sectional velocity LINE CURRENT CALCULATION Maximm kw for Sq. Ft. of Dct Area Dct width (feet) x dct height (feet) = dct area total ft 2 Max W = X kw x dct area ft 2 Line Crrent (Amperes (A)) = Watts (W) / Line Voltage (V) Example: 4 kw Heater = 4000 W Line Voltage = 240 V Line Crrent = 4000 W / 240 V = 16.7 A in 2 ft 2 For EK, X = 30 kw The minimm niform airflow in a dct is directly related to the inlet air temperatre. Consideration mst be given to both airflow across the and inlet air temperatre. 1. To calclate the kilowatts per sq. ft. of dct area, divide the total kilowatts reqired by the dct area. Example: Dct Size = 2ft. x 3ft. Total Kilowatts = = kw / Sq. Ft. 2. If the air handler eqipment is expressed in FPM, then a direct cross reference can be made by comparing the temperatre of the air (as it enters the dct ) to the kw rating on the chart of rated velocity (refer to chart at right). a. Draw a line horizontally from the kilowatt per sq. ft. reqired to the inlet air temperatre being sed. b. From this point of intersection on the inlet air crve, draw a line down vertically to establish the air velocity. c. The velocity shold never be lower than the velocity as determined from the chart. In cases where this is not tre, the velocity mst be increased or the kw reqired mst be redced. 3. In cases where the air handling eqipment is expressed in CFM, then convert to FPM by dividing the CFM by the dct area. Example: FPM = CFM Dct Area EK & RH SERIES KW AND TEMPERATURE RISE The following formla may be sed to determine the approximate total kw reqired when the CFM (air volme) and desired temperatre are known: kw = CFM x rt 3150 DUCT HEATER TEMPERATURE RISE The following formla may be sed to determine the approximate temperatre rise of a dct when the kw and CFM are known: rt = kw x 3150 CFM ft 2 RenewAire.com LIT069_02 (12/18)

HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION E L E CT R I C DUCT HEATER FLIPPABLE SHOWN RENEWAIRE ERV + ELECTRIC DUCT HEATER: A SINGLE-SOURCE SOLUTION RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL ELECTRIC DUCT HEATER

INSTALLATION, OPERATION & MAINTENANCE MANUAL ELECTRIC DUCT HEATER , OPERATION & MAINTENANCE MANUAL ELECTRIC FOR COMMERCIAL INDOOR APPLICATIONS EH SERIES EK SERIES RENEWAIRE.COM ELECTRIC ABOUT RENEWAIRE For over 30 years, RenewAire has been a pioneer in enhancing indoor

More information

Electric Duct Heaters

Electric Duct Heaters Electric Duct Heaters 12541_Tutco_Catalog.indd 1 3/4/11 8:46:01 AM TYPICAL HEATER CONSTRUCTION TUTCO, the world s largest supplier of open coil heating elements, produces the highest quality products in

More information

Electric Duct Heaters. IDHB & IDHC Series

Electric Duct Heaters. IDHB & IDHC Series Electric Duct Heaters IDHB & IDHC Series May 2014 1 Duct Heaters Greenheck has a complete line of configurable electric duct heaters that are perfectly suited to your HVAC application. Our CAPS configuration

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL ELECTRIC DUCT HEATER

INSTALLATION, OPERATION & MAINTENANCE MANUAL ELECTRIC DUCT HEATER , OPERATION & MAINTENANCE MANUAL FOR COMMERCIAL INDOOR APPLICATIONS EK SERIES RENEWAIRE.COM ABOUT RENEWAIRE For over 30 years, RenewAire has been a pioneer in enhancing indoor air quality (IAQ) in commercial

More information

MODEL FTGF2P (240 VAC)

MODEL FTGF2P (240 VAC) SUMMARY MODEL FTGF2P (240 VAC) OPTIONS SELECTION At the back of the thermostat, there are two selection switches to set yor preference. 1 2 Temperatre in C or F. Time in 12 or 24 hors. TO SET TIME AND

More information

TUTCO Inc. E Series Electric Single Duct VAV / Duct Heater Installation Instructions Heater Models EVH, ERH, EDH & RHE

TUTCO Inc. E Series Electric Single Duct VAV / Duct Heater Installation Instructions Heater Models EVH, ERH, EDH & RHE General for All Models TUTCO Inc. E Series Electric Single Duct VAV / Duct Heater Installation Instructions Heater Models EVH, ERH, EDH & RHE Inspect heater for any possible damage. Check all insulators

More information

WARNING Important Safety Information

WARNING Important Safety Information 2 Installation Premier Series Non-Programmable Thermostats MODEL 3300 Mlti-Stage 3 Heat / 2 Cool Ato Changeover Conventional and Heat Pmp Before Installing or Operating, PLEASE READ ALL INSTRUCTIONS 1

More information

Buderus Oil Boilers. Buderus G115 & G215.

Buderus Oil Boilers. Buderus G115 & G215. Bders Oil Boilers Bders G115 & G215 Bders residential oil boilers are designed to extract and deliver more heat from every fel dollar, and are available in higher otpts at less cost per BTU. www.boschheatingandcooling.com

More information

Loudspeakers Line Isolator System

Loudspeakers Line Isolator System Commnications Systems Lodspeakers Line Isolator System Lodspeakers Line Isolator System www.boschsecrity.com Provides redndant lodspeaker loops for pblic address and voice alarm systems Dramatically redces

More information

Standard Duct Heaters Open Coil

Standard Duct Heaters Open Coil HUA Slip-In and HUP Flanged Heaters The 80% Rule HEATREX recommends the heater should occupy at least 80% of the actual inside area of the duct, as shown in Figure 45. Only small amounts of air will bypass

More information

GEC Low-frequency Horn Strobes

GEC Low-frequency Horn Strobes Fire Alarm Systems GEC Low-freqency Horn Strobes GEC Low-freqency Horn Strobes Silence the horn while strobes flash Evacation tone Use the SperSlide featre for easy testing Wide voltage range; 16 to 33

More information

Electric Coils. Blower Coils. Product Information

Electric Coils. Blower Coils. Product Information Product Information General Information Electric heat coils are an available accessory for use with Price blower coil units. The electric heating coils have been specific ally designed to suit Price blower

More information

Duct Heater Product Catalog

Duct Heater Product Catalog Duct Heater Product Catalog Quick Turn & Expedited Options Standard lead time - 10 business days Expedited shipments in 1-6 business days WHO WE ARE... Our parent company, Smiths Group plc, employs over

More information

FAS 420 Series Aspirating Smoke Detectors LSN improved version

FAS 420 Series Aspirating Smoke Detectors LSN improved version Fire Alarm Systems FAS 420 Series Aspirating Smoke Detectors LSN improved version FAS 420 Series Aspirating Smoke Detectors LSN improved version www.boschsecrity.com Connectable to the fire panels FPA

More information

FMC 210 DM Double Action Call Points

FMC 210 DM Double Action Call Points Fire Alarm Systems FMC 10 DM Doble Action Call Points FMC 10 DM Doble Action Call Points www.boschsecrity.com Adjstment after alarm triggering Individal identification thanks to atomatic or manal detector

More information

M1 SERIES DUCT HEATERS

M1 SERIES DUCT HEATERS HEATRIX HEATRIX Electric Duct Heaters may be used with heat pumps, cooling units or any forced air system. Suitable for zero clearance installation with horizontal or vertical air flow. Auto reset primary

More information

FAP 520 Automatic Fire Detectors LSN improved version

FAP 520 Automatic Fire Detectors LSN improved version Fire Alarm Systems FAP 520 Atomatic Fire Detectors LSN improved version FAP 520 Atomatic Fire Detectors LSN improved version www.boschsecrity.com Modern, ltra-flat design Smooth, easily-cleaned detector

More information

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater. Duct Heaters Synheat duct heaters come in various sizes and dimensions to fit any compartment. There are three types of duct heaters available: open coil, tubular element or finned tubular heating elements

More information

I N T E G R AT E D P R O G R A M M A B L E CONTROLS OPTIMIZE ERV USABILITY AND PERFORMANCE EVERY BUILDING AND EVERY APPLICATION

I N T E G R AT E D P R O G R A M M A B L E CONTROLS OPTIMIZE ERV USABILITY AND PERFORMANCE EVERY BUILDING AND EVERY APPLICATION I N T E G R T E D P R O G R M M B L E OPTIMIZE ERV USBILITY ND PERORMNCE R ENE W I R E E V E RY WHE RE E V E R Y G E O G R P H Y, E V E R Y C L I M T E, E V E R Y H O M E, EVERY BUILDING ND EVERY PPLICTION

More information

Heatrix Electric Duct Heater HXOB Installation Instructions

Heatrix Electric Duct Heater HXOB Installation Instructions Heatrix Electric Duct Heater HXOB Installation Instructions General: Heatrix HXOB Style Electric Duct Heater has been tested and listed for close-coupled application with a forced air system (straight

More information

TABLE OF CONTENTS page 2

TABLE OF CONTENTS page 2 TABLE OF CONTENTS page 2 Metal Sheath Design... page 2 Mechanical Design...... page 3-7 Safety Protection...... page 7 Technical Design Data.....page 7 & 8 Temperature Control Guide...... page 8 Electrical

More information

LBB 1990/00 Plena Voice Alarm Controller

LBB 1990/00 Plena Voice Alarm Controller Commnications Systems LBB 1990/00 Plena Voice Alarm Controller LBB 1990/00 Plena Voice Alarm Controller www.boschsecrity.com Heart of the Plena Voice Alarm System EN 54 16 certified and EN 60849 compliant

More information

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTALLATION INSTRUCTIONS Nomenclature: D F I 0 0 H : Open coil element T: Tubular element F: Finned tubular element I: Slip in type F: Flange type 0: No screen left of the heater 1: Screen left of the heater 0: No screen right

More information

Auto Drain Valve. Longer life & Higher resistance to foreign matter. AD402-A Series CAT.ES40-65A. Improved foreign matter resistance

Auto Drain Valve. Longer life & Higher resistance to foreign matter. AD402-A Series CAT.ES40-65A. Improved foreign matter resistance Ato Drain Valve RoHS Longer life & Higher resistance to foreign matter Improved foreign matter resistance Catching of foreign matter is redced with no sliding part. Diaphragm type Poppet type Shape prevents

More information

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER August 2014 VERSION 1.2 Please read instructions carefully before installation. This NER unit is a fanless fresh air make-up package with an

More information

Custom Duct Heaters. Special Applications

Custom Duct Heaters. Special Applications Special Applications Air Conditioning & Air Handling Units For more than 55 years, INDEECO has been supplying special heaters for use in air handling and air conditioning equipment (Figure 49). A wide

More information

Custom Duct Heaters. Special Applications

Custom Duct Heaters. Special Applications Special Applications Air Conditioning & Air Handling Units For more than 50 years, INDEECO has been supplying special heaters for use in air handling and air conditioning equipment (Figure 50). A wide

More information

Lynergy Comfort Control SCR Electric Heater Application Guide

Lynergy Comfort Control SCR Electric Heater Application Guide AG-Lynergy-2 September 18, 217 Lynergy Comfort Control SCR Electric Heater Application Guide Titus Redefine your comfort zone. www.titus-hvac.com 65 Shiloh Road Plano, Texas 7574 972.212.4 Titus, the Titus

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

Series HF custom designed flange and insert heaters.

Series HF custom designed flange and insert heaters. Page 1 - GENERAL INFORMATION A - INTRODUCTION 1 - GENERAL DESCRIPTION A Duct Heater is a self contained heater designed to be installed in the field in an air stream of a duct system, external to the air

More information

LBB 1990/00 Plena Voice Alarm Controller

LBB 1990/00 Plena Voice Alarm Controller Commnications Systems LBB 1990/00 Plena Voice Alarm Controller LBB 1990/00 Plena Voice Alarm Controller www.boschsecrity.com Heart of the Plena Voice Alarm System EN 54 16 certified and EN 60849 compliant

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

SINGLE DUCT TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS Performance Data AHRI Certification and Performance Notes Model Series 3000 asic Unit AHRI Certification Rating Points VAV: Fiberglass Inlet Size Airflow cfm l/s Min. Inlet Ps w.g. Pa Discharge Sound Power

More information

FPA 1000 UL Analog Addressable Fire Panel

FPA 1000 UL Analog Addressable Fire Panel Fire Alarm Systems FPA 1000 UL Analog Addressable Fire Panel FPA 1000 UL Analog Addressable Fire Panel www.boschsecrity.com Spport for p to 508 points on two analog addressable loops Bilt in Ethernet connector

More information

ISC PPR1 WA16x Professional Series PIR Detectors with Anti mask

ISC PPR1 WA16x Professional Series PIR Detectors with Anti mask Intrsion Alarm Systems ISC PPR WA6x Professional Series PIR Detectors with Anti mask ISC PPR WA6x Professional Series PIR Detectors with Anti mask www.boschsecrity.com 6 m x m (5 x 7) standard coverage;

More information

( )

( ) (1-800-492-8826) www.wattco.com OVERVIEW WATTCO duct heaters are composed of open coil, tubular or finned tubular heating elements that are either flanged or inserted in the duct. WATTCO supplies two types

More information

(770) wwww.southgateprocess.com

(770) wwww.southgateprocess.com (770) 345-0010 wwww.southgateprocess.com OVERVIEW WATTCO duct heaters are composed of open coil, tubular or finned tubular heating elements that are either flanged or inserted in the duct. WATTCO supplies

More information

ASFP On-site guide to installing fire-stopping

ASFP On-site guide to installing fire-stopping ASFP On-site gide to installing fire-stopping ASFP On-site gide to installing fire-stopping In this gide fire-stopping incldes cavity barriers, penetration seals for services and linear joint seals. The

More information

AG Series Electric Heaters

AG Series Electric Heaters AG Series Electric Heaters Installation, Operation and Maintenance Instructions Internal Auxililary Electric Heat 97B0005N03 Table of Contents Overview 3 Vertical Upflow Installation 4 Horizontal Installation

More information

Professional Series TriTech+ Motion Detectors with Anti mask

Professional Series TriTech+ Motion Detectors with Anti mask Intrsion Alarm Systems Professional Series TriTech+ Motion Detectors with Anti mask Professional Series TriTech+ Motion Detectors with Anti mask www.boschsecrity.com 8 m x 5 m (60 ft x 80 ft) standard

More information

CC600PB Solution 144 Control Panel

CC600PB Solution 144 Control Panel Intrsion Alarm Systems CC600PB Soltion 144 Control Panel CC600PB Soltion 144 Control Panel www.boschsecrity.com 16 on-board zones (expandable to 144 wired or wireless), partitionable to 8 areas with 256

More information

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version Fire Alarm Systems FAP-420/FAH-420 Atomatic Fire Detectors LSN improved version FAP-420/FAH-420 Atomatic Fire Detectors LSN improved version www.boschsecrity.com Combination of optical, thermal and chemical

More information

FMC 420RW Single Action Call Points LSN improved

FMC 420RW Single Action Call Points LSN improved Fire Alarm Systems FMC 420RW Single Action Call Points LSN FMC 420RW Single Action Call Points LSN Alarm triggering by pressing the black marking or breaking the glass pane Protection against injry throgh

More information

FPA 1000 Analog Addressable Fire Panels

FPA 1000 Analog Addressable Fire Panels Fire Alarm Systems FPA 1000 Analog Addressable Fire Panels FPA 1000 Analog Addressable Fire Panels www.boschsecrity.com Spport for p to 508 points on two analog addressable loops Bilt-in Ethernet connector

More information

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER (USA)

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER (USA) INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER (USA) July 2017 VERSION 1.3 Please read instructions carefully before installation. This NER unit is a packaged fan-less fresh air make-up unit

More information

VAV FAN POWERED TERMINAL UNITS TABLE OF CONTENTS FAN POWERED TERMINAL UNITS. C-2 Excellence in Air Distribution MODEL KQFS MODEL KQFP MODEL QFC

VAV FAN POWERED TERMINAL UNITS TABLE OF CONTENTS FAN POWERED TERMINAL UNITS. C-2 Excellence in Air Distribution MODEL KQFS MODEL KQFP MODEL QFC VAV TABLE OF CONTENTS FS/ rueger models FS and fan powered terminal units were designed for optimal performance in noise sensitive applications. These series and parallel fan terminals utilize built-in

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS FANMATE FEATURING EZClip TM by MAXXAIR VENTILATION SOLUTIONS SUPERIOR RAIN PROTECTION OPTIONAL BUG SCREEN ASSEMBLY AND FOR MODELS: SMOKE 755, WHITE 855, AND BLACK 955 READ AND SAVE THESE INSTRUCTIONS WARNING:

More information

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version Fire Alarm Systems FAP-420/FAH-420 Atomatic Fire s LSN improved version FAP-420/FAH-420 Atomatic Fire s LSN improved version www.boschsecrity.com Combination of optical, thermal and chemical sensors with

More information

D2212BE Control Panel

D2212BE Control Panel Intrsion Alarm Systems DBE Control Panel DBE Control Panel www.boschsecrity.com Eight (maximm) on-board points Eight sers and passcodes with three athority levels Two programmable on-board relay otpts

More information

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER September 2017 VERSION 1.5 Please read instructions carefully before installation. This unit is a complete fresh air make-up package with an integrated

More information

LSN RF Fire Detection System

LSN RF Fire Detection System 17 19 18 34 3 50 49 21 20 36 35 52 51 23 2 38 37 54 53 24 10 26 25 40 39 5 57 56 13 12 28 27 42 41 59 58 15 14 30 29 4 43 61 60 16 32 31 46 45 63 62 48 47 64 Fire Alarm Systems LSN RF Fire Detection System

More information

TETRA Secury System funkwerk TSS: The future of professional mobile communication.

TETRA Secury System funkwerk TSS: The future of professional mobile communication. TETRA Secry System fnkwerk TSS: The ftre of professional mobile commnication. The TETRA-based radio alarm system with telephony integration and precise localisation Fnkwerk Secrity Commnications Secrity.

More information

FMC 420RW Single Action Call Points LSN improved

FMC 420RW Single Action Call Points LSN improved Fire Alarm Systems FMC 420RW Single Action Call Points LSN improved FMC 420RW Single Action Call Points LSN improved www.boschsecrity.com Alarm triggering by pressing the black marking or breaking the

More information

B465 Universal Dual Path Communicator

B465 Universal Dual Path Communicator Intrsion Alarm Systems B465 Universal Dal Path Commnicator B465 Universal Dal Path Commnicator www.boschsecrity.com The B465 Conettix Universal Dal Path Commnicator converts the Pblic Switch Telephone

More information

Construction Electrical

Construction Electrical INDEECO offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the previous section, makes it easy to specify

More information

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts Standard Construction Control Options HEATREX offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the

More information

FCS-8000-VFD-B Video-based fire detection

FCS-8000-VFD-B Video-based fire detection Fire Alarm Systems FCS-8000-VFD-B Video-based fire detection FCS-8000-VFD-B Video-based fire detection www.boschsecrity.com Very fast fire and smoke detection Robst against false alarms Covers large monitoring

More information

CUSTOM BUILT TO ORDER LISTED STOCK MODELS STANDARD RIBBED OR HIGH PERFORMANCE ARROWHEAD CERAMIC INSULATORS MODEL SERIES: DH

CUSTOM BUILT TO ORDER LISTED STOCK MODELS STANDARD RIBBED OR HIGH PERFORMANCE ARROWHEAD CERAMIC INSULATORS MODEL SERIES: DH CUSTOM BUILT TO ORDER LISTED STOCK MODELS STANDARD RIBBED OR HIGH PERFORMANCE ARROWHEAD CERAMIC INSULATORS MODEL SERIES: DH CONTENTS Page No. Warranty 2 Introduction 3 Rush Program 3 Available Models 3

More information

MANUAL INSTALLATION + SERVICE. Electric Coils. For VAV Terminals. v100 Issue Date: 01/09/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION + SERVICE. Electric Coils. For VAV Terminals. v100 Issue Date: 01/09/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION + SERVICE Electric Coils For VAV Terminals v100 Issue Date: 01/09/18 2018 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview General...1 Caution To Contractors...1

More information

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax AllStyle Coil Company, LP 7037 Brittmore Houston, TX 77041 Phone 713-466-6333 Fax 713-466-6363 April 2005 VL / VLX Series Air Handler VL / VLX Series Air Handlers Installation Operation Maintenance The

More information

B465 Universal Dual Path Communicator

B465 Universal Dual Path Communicator Intrsion Alarm Systems B465 Universal Dal Path Commnicator B465 Universal Dal Path Commnicator www.boschsecrity.com The B465 Conettix Universal Dal Path Commnicator converts the Pblic Switch Telephone

More information

Bulletin A Brasch Manufacturing Co., Inc.

Bulletin A Brasch Manufacturing Co., Inc. Bulletin A102-1 Brasch Manufacturing Co., Inc. Index Bottom Insert.................... 11 Raintight Construction.............. 11 Bottom Outlet.................... 12 Recessed Terminal Box..............

More information

Chilled Water DOAS Fan Powered Terminal Units

Chilled Water DOAS Fan Powered Terminal Units Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner

More information

Professional Series LSN TriTech+ Motion Detectors with Anti mask

Professional Series LSN TriTech+ Motion Detectors with Anti mask Intrsion Alarm Systems Professional Series LSN TriTech+ Motion Detectors with Professional Series LSN TriTech+ Motion Detectors with www.boschsecrity.com 8 m x 5 m (60 ft x 80 ft) standard coverage; 8

More information

FPA 1000 Analog Addressable Fire Panels

FPA 1000 Analog Addressable Fire Panels Fire Alarm Systems FPA 1000 Analog Addressable Fire Panels FPA 1000 Analog Addressable Fire Panels www.boschsecrity.com Spport for p to 508 points on two analog addressable loops Bilt-in Ethernet connector

More information

4Up to 40kW per sq. ft. (24 kw per sq. ft.) 4Modulating, ON/OFF or staging 4Standard from 0.5 to 1000 kw, larger loads available

4Up to 40kW per sq. ft. (24 kw per sq. ft.) 4Modulating, ON/OFF or staging 4Standard from 0.5 to 1000 kw, larger loads available The Neptronic electric heater is manufactured using the most advanced technologies available. Total automation from design to production using integrated CAD/CAM systems not only assures maximum efficiency,

More information

B465 Universal Dual Path Communicator

B465 Universal Dual Path Communicator Intrsion Alarm Systems B465 Universal Dal Path Commnicator B465 Universal Dal Path Commnicator www.boschsecrity.com Compatible with control panels sing Contact ID, SIA, Plse 3/1 or Plse 4/2 commnication

More information

Fireray5000-EN. Fire Alarm Systems Fireray5000-EN. Extended monitoring range. Up to 2 detectors per system controller

Fireray5000-EN. Fire Alarm Systems Fireray5000-EN.  Extended monitoring range. Up to 2 detectors per system controller Fire Alarm Systems Fireray5000-EN Fireray5000-EN www.boschsecrity.com Extended monitoring range Up to 2 detectors per system controller Two pairs of fire and falt relays (one per detector) Transmitter

More information

B9512G Control Panels

B9512G Control Panels Intrsion Alarm Systems B9512G Control Panels B9512G Control Panels www.boschsecrity.com Flly integrated intrsion, fire, and access control allows sers to interface with one system instead of three Spports

More information

Visit our web site at

Visit our web site at TABLE OF CONTENTS National Environmental Products ltd. Tel: 1 800 361-2308 Fax:(514) 333-3163 Customer Service Fax: (514) 333-1091 Business hours: from Monday to Friday, 8:00A.M. to 5:00P.M. (North American

More information

Commercial Duct Heaters. Our products do more in a wide range of applications. Expect More.

Commercial Duct Heaters. Our products do more in a wide range of applications. Expect More. Commercial Duct Heaters Our products do more in a wide range of applications. Expect More. Introduction Indeeco designs and manufactures commercial and industrial electric heating and control systems that

More information

Control Panel-Based Alarm System

Control Panel-Based Alarm System Control Panel-Based Alarm System Installation Programming Operating Keep this manal safe for reference and ftre maintenance Introdction Contents Thank yo for choosing the Yale Wireless Alarm System. This

More information

Commercial Heating Products. Our products do more in a wide range of applications. Expect More.

Commercial Heating Products. Our products do more in a wide range of applications. Expect More. Commercial Heating Products Our products do more in a wide range of applications. Expect More. Indeeco pioneered the application of duct heaters in commmercial construction applications. Today, Indeeco

More information

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL BC(E) SERIES INDOOR / OUTDOOR MANUFACTURED BY GENERAL INFORMATION PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: TELEPHONE: INSTALLATION

More information

6 Advanced Programming

6 Advanced Programming 6 Advanced Programming 6.1 Program Codes This chapter provides the Program Codes table which smmarizes the wide variety of available programming operations, along with a description and comments. Additional

More information

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

engineering guide FH Fan-Coil Units Low-Profile, Horizontal engineering guide FH Fan-Coil Units Low-Profile, Horizontal FORM 115.26-EG7 (908) Table of contents FH Fan-Coil Units Low-Profile, Horizontal Features and Benefits... Construction Features... Standard

More information

Hot Water Dispenser. Important: Read and save these instructions.

Hot Water Dispenser. Important: Read and save these instructions. Part No. 3184330 nstallation nstrctions/use and Care Gide Hot Water Dispenser mportant: Read and save these instrctions. MPORTANT: nstaller: Leave nstallation nstrctions with homeowner. Homeowner: Keep

More information

Blue Line Gen2 TriTech Motion Detectors

Blue Line Gen2 TriTech Motion Detectors Intrsion Alarm Systems Ble Line Gen2 TriTech Motion Detectors Ble Line Gen2 TriTech Motion Detectors www.boschsecrity.com Pet friendly Selectable model available optimize installation for pet (45 kg [00

More information

Blue Line Gen2 TriTech Motion Detectors

Blue Line Gen2 TriTech Motion Detectors Intrsion Alarm Systems Ble Line Gen2 TriTech Motion Detectors Ble Line Gen2 TriTech Motion Detectors www.boschsecrity.com Pet friendly Selectable model available optimize installation for pet (45 kg [00

More information

ICP-AMAX3-P2-BE Intrusion panel, fr/de/nl/pt

ICP-AMAX3-P2-BE Intrusion panel, fr/de/nl/pt Intrsion Alarm Systems ICP-AMAX3-P2-BE Intrsion panel, fr/de/nl/pt ICP-AMAX3-P2-BE Intrsion panel, fr/de/nl/pt www.boschsecrity.com 32 zones / 8 areas / 128 ser codes On-board voice dialer Macro fnctionality

More information

D2212B Control Panel. Intrusion Alarm Systems D2212B Control Panel. Eight on-board points. Up to 24 wired or wireless points

D2212B Control Panel. Intrusion Alarm Systems D2212B Control Panel.   Eight on-board points. Up to 24 wired or wireless points Intrsion Alarm Systems DB Control Panel DB Control Panel www.boschsecrity.com Eight on-board points Up to wired or wireless points Eight sers and passcodes with three athority levels Two programmable on-board

More information

WEATHER ALARM WR. Installation Manual

WEATHER ALARM WR. Installation Manual WEATHER ALARM WR Installation Manual BARTLETT Instrument Co. 1032 Ave. H Fort Madison, IA 52627 319-372-8366 www.bartinst.com 2/22/18 1 INSTALLATION OVERVIEW The main function of the Weather Alarm is to

More information

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-23 82 43.00 40 (August 2011) ----------------------------------- Preparing Activity: NASA Superseding UFGS-23 82 43.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

ICP-AMAX4-P3-EN Intrusion panel, en/es/pl/sv

ICP-AMAX4-P3-EN Intrusion panel, en/es/pl/sv Intrsion Alarm Systems ICP-AMAX4-P3-EN Intrsion panel, en/es/pl/sv ICP-AMAX4-P3-EN Intrsion panel, en/es/pl/sv www.boschsecrity.com 64 zones / 16 areas / 250 ser codes On-board voice dialer Macro fnctionality

More information

Vertical Upflow Horizontal Left Air Handlers

Vertical Upflow Horizontal Left Air Handlers Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with

More information

Asphalt. Tel: +44 (0) u Fax: +44 (0) u

Asphalt. Tel: +44 (0) u Fax: +44 (0) u Asphalt 45 Analysis and Binder Recovery 45 Design and Testing of Bitminos Mixtres 45 Specific Gravity 46 Bitmen and Tar 47 Temperatre and Density 47 Core Drilling 47 Pavement The main engineering se of

More information

Professional Series Intrusion Detector Knows when to alarm. Knows when not to. Back. Now Featuring Multi-Point Anti-Mask with Spray Detect

Professional Series Intrusion Detector Knows when to alarm. Knows when not to. Back. Now Featuring Multi-Point Anti-Mask with Spray Detect Professional Series Intrsion Detector Knows when to alarm. Knows when not to. Back Now Featring Mlti-Point Anti-Mask with Spray Detect Intelligent motion detection with nmatched versatility If yo cold

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 82 43.00 40 (May 2017) --------------------------------- Preparing Activity: NASA Superseding UFGS-23 82 43.00 40 (August 2014) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Neptronic Toll Free: TEL: (514) Fax:(514)

Neptronic Toll Free: TEL: (514) Fax:(514) TABLE OF CONTENTS Neptronic Toll Free: 1 800 361-2308 TEL: (514) 333-1433 Fax:(514) 333-3163 Business hours: from Monday to Friday, 8:00A.M. to 5:00P.M. (Eastern time) E-Mail: contact@neptronic.com Introduction...1

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

CR1 Series Triton Corrosion Resistant Washdown Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters CR1 Series Triton Corrosion Resistant Washdown Heaters Ruffneck CR1 Triton Series is a new generation of NEMA 4X corrosion-resistant washdown heaters. The first UL listed Type 4X heater with models ranging

More information

HEALTHY HOME AIR PURIFICATION SYSTEM

HEALTHY HOME AIR PURIFICATION SYSTEM HEALTHY HOME AIR PURIFICATION SYSTEM MODELS: TRIO 1200 & TRIO 2000 INSTALLATION AND OPERATION Field Controls, 2630 Airport Road, Kinston, NC 28504 *(252)522-3031* www.fieldcontrols.com Table of Contents

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

ICP-AMAX3-P2-EN Intrusion panel, fr/de/nl/pt

ICP-AMAX3-P2-EN Intrusion panel, fr/de/nl/pt Intrsion Alarm Systems ICP-AMAX3-P2-EN Intrsion panel, fr/de/nl/pt ICP-AMAX3-P2-EN Intrsion panel, fr/de/nl/pt www.boschsecrity.com 32 zones / 8 areas / 128 ser codes On-board voice dialer Macro fnctionality

More information

Zehnder ComfoInline Heater

Zehnder ComfoInline Heater Zehnder ComfoInline Heater Specifications and Installation Guidelines This unit complies With CSA and UL SDHR5-1.5K120V1P-CIRO17-OTDD-OEMZ standards SDHR6-2.5K220V1P-CIRO17-OTDD-OEMZ SDHR7-3.5K220V1P-CIRO17-OTDD-OEMZ

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting

More information