240 Series Unit Heater SameDay Shipping

Size: px
Start display at page:

Download "240 Series Unit Heater SameDay Shipping"

Transcription

1 SameDay Shipping Now Available on Select s The unit heater is available in four unit sizes with 9 standard models with ratings up to 0 KW at voltages of 20, 240, 277, 40 and 600 single or three-phase. They are available with a wide variety of factory built-in or field-installed options. Shown with optional diffuser Temperature Control: Single-stage or two-stage control with built-in or remote-mounted thermostats are available on all heaters. Applications actories Garages Mechanical Rooms Pump ouses Service Areas in Air andling s Shipping and Receiving Areas Storage Areas Warehouses Workshops Control Options: Available as factory built-in or field-installed to meet job specifications. Custom KW s: Custom KW s are available up to 0 KW. Discharge Direction: The heater can be mounted for horizontal or vertical discharge using an optional universal wall/ceiling mounting bracket or with field-furnished threaded rods for ceiling mounting. Color Options: The standard color is camel. Six optional colors are available: grey, yellow, red, white, blue or textured beige. eaters may also be supplied with unpainted corrosion resistant galvanized steel. See back cover for color samples. Standard Construction eatures eating lements - Industrial grade, 0.47 diameter steel sheath with brazed copper plated steel fins and epoxy sealed ends. Draw-thru airflow design pulls air across the heating elements to ensure cool element operation and even air distribution resulting in long element life. ousing - eating elements and motor are enclosed in a heavy gauge galvanized steel cabinet with a durable camel polyester powder coat finish. Outlet Grille - Individually adjustable louvers are provided to direct airflow. A protective outlet fan guard is provided to prevent insertion of foreign objects. an Motor - Permanently lubricated and thermally protected motor. Built-in Controls - All units include an automatic reset thermal cutout that will de-energize the heater if an overtem- perature condition occurs. A manual reset thermal cutout, in addition to an automatic reset thermal cutout, is standard on heaters 10 KW and above. A fan delay is provided to allow the elements to heat up before fan startup and purges the heater of residual heat after shutdown. A 24-volt transformer and disconnecting contactor are provided on most heaters. Single-phase heaters rated at KW or less have line voltage controls; 24-volt control and contactor are available. Power fusing is standard on all heaters rated over 4 amps. Mounting Universal horizontal or vertical discharge. Optional diffusers are available for vertical discharge. An Anemostat diffuser can be used to provide draft-free air movement at lower mounting heights. or higher mounting heights, radial diffuser with adjustable fins can be used to increase floor coverage or adjusted for a vertical down blast of air. 34

2 actory Built-in Options Code Consult actory D M P (1) R1 R2 (1) (2) Custom KW - CONSULT ACTORY Power disconnect switch using under 4 Amps, not available on heaters size 1 and size 2 or size 3 at 600V Manual Reset Cutout (In addition to automatic cutout) on heaters up to 10KW eater On Pilot Light Built-in 24V transformer and contactor for 2. to KW, single phase heaters. 0V Transformer to replace 24V Transformer S1 Summer an Switch S2 (1) Summer an Switch Remote Pilot Duty Built-in Thermostat Stage T Built-in Thermostat Stage (Option X required) V1* Anemostat (Cone) Diffuser V2 Radial Diffuser X (2) 2-Stage Control * consult factory for lead times (1) When specifying Option P, R2, or S2 for single-phase heaters rated up to KW; Option R1 must also be specified. (2) Option R2 and X cannot be combined on heaters rates up to KW. ield-installed Options (shipped loose for field installation into heater) B Anemostat (Cone) Diffuser size 1 B Anemostat (Cone) Diffuser size 2 and 3 B Anemostat (Cone) Diffuser size 4 B Radial Diffuser size 1 B Radial Diffuser size 2 and 3 B Radial Diffuser size 4 B orizontal Dust Shield size 1 and 2 B orizontal Dust Shield size 3 B orizontal Dust Shield size 4 B Disconnect Switch, 600V, Three-Pole, 32 Amp B Disconnect Switch, 600V, Three-Pole, 64 Amp B B B B (1) B (1)(2) B B B (1) B B Disconnect Switch, 600V, Three-Pole, 0 Amp Built-in Thermostat Stage Built-in Thermostat Stage (Option X required) eater On Pilot Light (24V) eater On Pilot Light (0V) Summer an Switch - Built-in up to 277V Summer an Switch- Built-in, over 277V, 24V Control Summer an Switch - Remote, 24V Control Summer an Switch - Built-in, over 277V, 0V Control Summer an Switch - Remote, 0V Control (1) When specifying Option P, R2, or S2 for single-phase heaters rated up to KW; Option R1 must also be specified. (2) Option R2 and X cannot be combined on heaters rates up to KW. Vertical Mounting Air Pattern Table Used on Max Mtg. eight ft. (m) A ft (m) B ft (m) WITOUT DIUSR or a straight downward air pattern, directional louvers can be removed in order to maximize airflow. 2 (.) 3 (11.6) 6 (20.7) DIRCTIONAL LOUVRS (standard) Provides a directional (straight line) airflow which results in a rectangular air pattern. Louvers can be adjusted through a 3 degree range of motion 22 (6.7) 40 (.2) 3 (.2) (2.9) (3.7) 27 (.2) 4 (13.7) ANMOSTAT DIUSR Ideal for low mounting heights. abricated using 3 diverging hollow cones which disperse heat to the floor area at a minimum velocity for comfort. 9 (2.7) 13 (4.0) 21 (6.4) 29 (.) 40 (.2) 6 (20.7) RADIAL DIUSR Ideal for high ceiling mounting. Louvers can be adjusted to direct airflow straight down when fully open to 4 degrees in a radial pattern which increases floor coverage by approxiately 20%. OPN 4 9 (2.7) 11 (3.4) 1 (4.) 1 (.) 30 (9.1) 3 (11.6) 6 (19.) 24 (7.3) 36 (11.0) 46 (14.0) 7 (23.) 3

3 36 eater Listing KW Volts Ph Total Amps* Approx. Air Temperature Rise ( C) 2-Stage Control Std. Control Voltage Optional low voltage transformer and contactor are available for these heaters, see actory Built-in Option R1. (3) using, Option not avaliable. Option R2 (0V Control) is standard, 24V avaliable (2) B 20 1 B-240-U102C (13) 1B B-240-U102J B B-240-U102N B 20 1 B-240-U1033C (1) 1B B-240-U1033J B B-240-U1033N (19) 1A 24 1 B-240-U1037U A 24 1 B-240-U103D 3 (20) A 24 1 B-240-U103K B 20 1 B-240-U100C B B-240-U100J B B-240-U100N 46 (26) A 24 1 B-240-U100D A 24 1 B-240-U100K A 24 1 B-240-U100U B 24 2 B-240-U2067C (19) 1B 24 2 B-240-U2067J B 24 2 B-240-U2067N B 24 2 B-240-U207C B 24 2 B-240-U207J (21) 1A 24 2 B-240-U207D A 24 2 B-240-U207K A 24 2 B-240-U207U (2) 1B 24 2 B-240-U2099C B 24 2 B-240-U2100J B 24 2 B-240-U2100N (2) 1A 24 2 B-240-U2100D A 24 2 B-240-U2100K A 24 2 B-240-U2100U (22) 1B 24 3 B-240-U3132N Standard 24 3 B-240-U3133C-X (1) 39 (22) Standard 24 3 B-240-U3133J-X B 24 3 B-240-U310D B 24 3 B-240-U310K 44 (2) B 24 3 B-240-U310U B 0 3 B-240-U310Z (3) Standard 24 3 B-240-U3199C-X (1) 9 (33) B 24 3 B-240-U3199K Standard 24 3 B-240-U3200J-X (1) Standard 24 3 B-240-U3200N-X (1) (33) Standard 24 3 B-240-U3200D-X B 24 3 B-240-U3200U B 0 3 B-240-U3200Z (3) Standard 24 4 B-240-U420D-X Standard 24 4 B-240-U420K-X 27 (1) B 24 4 B-240-U420U B 24 4 B-240-U420Z Standard 24 4 B-240-U4333D-X Standard 24 4 B-240-U4333K-X 36 (20) B 24 4 B-240-U4333U B 24 4 B-240-U4333Z Standard 24 4 B-240-U437D-X Standard 24 4 B-240-U437K-X 40 (23) A 24 4 B-240-U437U A 24 4 B-240-U437Z (30) Standard 24 4 B-240-U449D-X Standard 24 4 B-240-U400K-X (30) Standard 24 4 B-240-U400U-X Standard 24 4 B-240-U400Z-X *Total Amps = eating element amps and motor amps. (1) Disconnect switch unavailable. (2) All Standard heaters are supplied with transformer and contactor except up to KW single-phase units. 2-stage heaters can be field wired as single stage. 1A = Optional 2-stage control, unbalanced (option X) 1B = Optional 2-stage control, balanced (option X).

4 eater Dimensions KW W Depth A B C D G I J 1 up to.7 (327) (40) 7.62 (194) 10.1 (24) 1 (47) 10 (24) (4) (4) 2.1 to 10.7 (429) (6) 7.62 (194) 6 () 10.1 (237) 1 (47) 10 (24) (4) (4) to 20.7 (429) (6) (29) 6 ().313 (237) 1 (47) (30) (30) 32 (13) (27) (27) to (64) 3.00 (902) 1.62 (397) 6.21 (236) (30) 13 (330) (30) 32 (13) 7 (17).92 (32) 7 (17).92 (32) CILING CILING IG. 1 ORIZONTAL MOUNTING WIT MOUNTING ARM IG. 2 ORIZONTAL CILING MOUNT WIT MTG ARM CILING CILING MIN ACCSS DOOR CLARANC w C INLT GRILL CLARANC TO ANY (3 SIDS) ' (2.4M) MINIMUM TO LOOR IG. 3 ORIZONTAL CILING MOUNT WIT TRADD ROD IG. 4 VRTICAL CILING MOUNT WIT MTG ARM 37

5 G J I RST MIN ACCSS DOOR CLARANC CILING AIRLOW 6" (mm) MIN. INLT GRILL CLARANC TO ANY (3 SIDS) ' (2.4M) MINIMUM T0 LOOR IG. TRADD ROD (3/ - ) ATTACMNT POINT DIMNSIONS IG. 6 VRTICAL CILING MOUNT WIT TRADD ROD Mounting Brackets B Universal wall & ceiling mounting bracket up to 10 KW (size 1 and 2) B Universal wall & ceiling mounting bracket over 10 KW up to 20 KW (size 3) B Universal wall & ceiling mounting bracket over 20 KW (size 4) Remote Thermostat Selection Chart KW Volts Ph 1-Stage Line Voltage 1-Stage Low Voltage (b) 2-Stage Low Voltage (b) B-240-U102C (a) (a) 2. B-240-U102J (a) (a) B-240-U102U (a) (a) B-240-U1033C (a) (a) 3.3 B-240-U1033J (a) (a) B-240-U1033N (a) (a) 3.7 B-240-U1037U 40 3 NA B-240-U103D 20 3 NA B-240-U103K NA B-240-U100C 20 1 NA (a) (a) B-240-U100J (a) (a) B-240-U100N (a) (a) All Other 240 Ser eaters NA (a) Add option R1 for 24V control on these units. (b) Option R2 is unavailable with any Brasch supplied remote low voltage thermostats. *Add option code to catalog number, mounting brackets or field installed options where applicable inish/color Options Code inish Color None Camel A0 Grey A1 Polyester Yellow A2 Powder Coat Red A3 White A4 Blue A Galvanized Steel (unpainted) Airflows, Weights and Air Throw CM Installed Weight lb (kg) Max. Air Throw ft. (m) (11.3) (1.1) 1 (.) (2) 41 (.) (70.3) 62 (1.9) 3 A7 Polyester Powder Coat Beige

Wall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls

Wall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls Wall, Ceiling and Floor Heaters Commercial & Industrial Electric heating and controls Our products do more in a wide range of applications. Expect More. Introduction INDEECO offers commercial and industrial

More information

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to

More information

Thermal Devices, Inc. Mount Airy, Maryland USA

Thermal Devices, Inc. Mount Airy, Maryland USA Unit Heater 2.6-50 kw 8,900 170,600 Btuh 208, 240, 277, 480, and 600 volt 1 or 3 phase Wall or Ceiling Mounted Canadian Standards Standards Description The Chromalox self-contained blower heater provides

More information

Industrial Air Heaters

Industrial Air Heaters HVH Horizontal or Vertical Discharge Fan Forced Unit Heater Industrial Air Heaters 2.6-50 kw 8,900 170,600 Btuh 208, 240, 277, 480, and 600 volt 1 or 3 phase Vertical or Horizontal Airflow Wall or Ceiling

More information

CR1 Series Triton Corrosion Resistant Washdown Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters CR1 Series Triton Corrosion Resistant Washdown Heaters Ruffneck CR1 Triton Series is a new generation of NEMA 4X corrosion-resistant washdown heaters. The first UL listed Type 4X heater with models ranging

More information

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater Toll-Free: 1-800-462-4983 Hazardous Location Fan Forced Unit Heater 3-25KW for Class I, Group C & D, Division 1 & 2 and Class II, Groups E, F & G, Divisions 1 & 2. Designed for rugged industrial applications

More information

LUH HORIZONTAL FAN-FORCED UNIT HEATER

LUH HORIZONTAL FAN-FORCED UNIT HEATER LUH HORIZONTAL FAN-FORCED UNIT HEATER VERSATILE, FAN-FORCED HEATING FOR COMMERCIAL AND INDUSTRIAL COMFORT HEAT APPLICATIONS Horizontal airflow Wall or ceiling mounting Self-contained Totally enclosed fan

More information

Electric Unit Heaters

Electric Unit Heaters Electric Unit Heaters Model UHEC Horizontal Discharge Model UHEC Vertical Discharge Model UHRA Hose-Down Model UHXA Explosion-Proof December 2001 Features and Benefits Model UHEC Electric Unit Heaters

More information

Description. Construction

Description. Construction LUH LUH PDS Horizontal Unit Heater 2.6 to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

KUH. Horizontal Unit Heater. Applications. Description

KUH. Horizontal Unit Heater. Applications. Description KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

Comfort. Description. Applications

Comfort. Description. Applications Blower Heater 3-35 kw 10,00-119,40 Btuh 40 to 90 Volts, 50/0 Hz 31 Stainless Steel Case Shown 3 Phase ATEX, GOST, CE IIG Exd IIB T3 Description Type is designed to heat areas classified as hazardous locations

More information

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S ULTRA-SAFE EXP U N I T E X P L O S I O N - P R O O F S Applications Aircraft Hangars/Service Areas hemical Storage/Handling Areas oal Preparation Plants ompressor Stations Grain Elevators Oil Refineries

More information

SUBMITTAL SCHEDULE & DATA

SUBMITTAL SCHEDULE & DATA SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model

More information

961 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting

961 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting 961 SERIES CONFINED SPACE UNIT EATER orizontal or Vertical Mounting ATTENTION: Read carefully before attempting to install or operate Unit eater. FEATURES: Forced air electric unit heater available in:

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

Brasch Hazardous Location Unit Heaters

Brasch Hazardous Location Unit Heaters Brasch Hazardous Location Unit Heaters BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain

More information

Type UB-2502A and UB-3002A Forced-Air Heater

Type UB-2502A and UB-3002A Forced-Air Heater Installation, Operation and RENEWAL PARTS IDENTIFICATION 4 (Supersedes PF423-3) JULY, 2002 Type UB-2502A and UB-3002A Forced-Air Heater UB PF423-4 161-027048-001 Figure 1 (Wall Mounted) Figure 2 (Ceiling

More information

5700 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting

5700 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting 5700 SERIES CONFINED SPACE UNIT EATER orizontal or Vertical Mounting MAINTENANCE MANUAL & INSTALLATION INSTRUCTIONS ATTENTION: Read carefully before attempting to install or operate Unit eater. I NTERTEK

More information

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

Electric Unit Heaters for Standard and Hazardous (Classified) Locations 2-116. January, 07 Electric Unit eaters for Standard and azardous (Classified) Locations MODEL ER MODEL VE MODEL PTE MODEL EX table of contents Table of Contents Page Electric Unit eaters - Models ER,

More information

HLA Series Hazardous Location Fan Forced Unit Heater

HLA Series Hazardous Location Fan Forced Unit Heater Products Company Markel Products Company Markel Products Company Markel Products Co HLA Series Hazardous Location Fan Forced Unit Heater FAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR CLASS I, GROUP C &

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

HLA Series Hazardous Location Fan Forced Unit Heater

HLA Series Hazardous Location Fan Forced Unit Heater HLA Series Hazardous Location Fan Forced Unit Heater FAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR CLASS I, GROUP C & D, DIVISION 1 & 2 AND CLASS II, GROUPS E, F & G, DIVISIONS 1 & 2. Shown with optional

More information

Ultra-Safe EXP Unit Heater

Ultra-Safe EXP Unit Heater INDEEO s ULTRA-SAFE EXP explosion-proof unit heater is designed with both safety and versatility in mind. Unique ULTRA-SAFE EXP features include: Industry s Lowest Ignition Temperature ode Rating: T3,

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

Rittling Unit Heaters. Catalog. Cooling

Rittling Unit Heaters. Catalog. Cooling Rittling Unit eaters Catalog eating Cooling Fresh Air Clean Air Zehnder everything you need to create a comfortable, healthy and energy-efficient indoor climate eating, cooling, fresh and clean air: at

More information

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual 238 Series Industrial/Commercial Electric Unit Heater Owner s Manual This manual covers installation, operation and maintenance. Read carefully before attempting to install, operate or service the 238

More information

CF1 ProVector Explosion-Proof Heaters

CF1 ProVector Explosion-Proof Heaters CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations

More information

SECTION (15767) - UNIT HEATERS

SECTION (15767) - UNIT HEATERS SECTION 23 82 39 (15767) - UNIT HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Unit Heaters. 2. Cabinet Unit Heaters. 3. Duct Heaters. 4. Baseboard Heaters. B. Related Sections: 1. Section

More information

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater Selectable Wattages, Back Cans, And Power Disconnects Furnish and install Electric Forced Air Heaters, Series 3380 where specified. The heaters shall be constructed of a heavy gauge steel housing. The

More information

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

Electric Unit Heaters for Standard and Hazardous (Classified) Locations 2-6.4 August, 09 Electric Unit eaters for tandard and azardous (Classified) Locations MODEL ER MODEL VE MODEL PTE MODEL EX table of contents Table of Contents Page Electric Unit eater Design Benefits Introduction...3

More information

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C) The Norseman Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions. Norseman unit heaters are available

More information

COLD WEATHER PRODUCTS CATALOG

COLD WEATHER PRODUCTS CATALOG COLD WEATHER PRODUCTS CATALOG Cold Weather Products Table of Contents Product Description Page Industrial Air and Radiant Heaters Industrial Unit Heaters and Accessories HVH Horizontal or Vertical Airflow

More information

ELECTRIC UNIT HEATERS FOR STANDARD AND HAZARDOUS (CLASSIFIED) LOCATIONS

ELECTRIC UNIT HEATERS FOR STANDARD AND HAZARDOUS (CLASSIFIED) LOCATIONS ELECTRIC UNIT EATER FOR TANDARD AND AZARDOU (CLAIFIED) LOCATION MODEL ER MODEL VE MODEL PTE MODEL EX 2-6.6 FEBRUARY, 17 TABLE OF CONTENT Table of Contents Page Electric Unit eater Design Benefits Introduction...3

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

HD3D Forced-Air Heater

HD3D Forced-Air Heater Installation, Operation and Maintenance Instructions HD3D Forced-Air Heater Corrosion Resistant/Hose Down PF200-8 6-30552-00 July 207 Table of Contents Section Page. Warnings... 3 2. Optional Equipment...

More information

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series) Stars Management JLT SUBMITTAL EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series) Tel: 00971 (04) 457 2383 Fax: 00971 (04) 457 2382 P.O. Box: 25867 Dubai U.A.E. E-mail: info@starsmanagementjlt.com Website:

More information

EMI ENGINEERING SUBMITTAL

EMI ENGINEERING SUBMITTAL (MH4) MULTI-ZONE HEAT PUMP AIR CONDITIONING SYSTEM Rev. 1.4 [3/05] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT DESIGNATION:

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

Chromalox Electric Airduct Heaters with Fintube Heating Elements. Conduit Entrance Plate. DHRF Remote Controls Flanged Type Figure 4

Chromalox Electric Airduct Heaters with Fintube Heating Elements. Conduit Entrance Plate. DHRF Remote Controls Flanged Type Figure 4 Chromalox DIVISION SALES REFERENCE DATE 4 (Supersedes PF455-2) FEBRUARY, 2001 SECTION Chromalox Electric Airduct eaters with Fintube eating Elements D PF455-3 161-562766-001 Conduit Entrance Plate DII

More information

3480/RCH SERIES INSTALLATION INSTRUCTIONS

3480/RCH SERIES INSTALLATION INSTRUCTIONS 3480/RCH SERIES INSTALLATION INSTRUCTIONS NOTE: If plaster frame is required for installation order it as an option. ATTENTION: Read carefully before attempting to install or operate the heater. GENERAL

More information

Description. Applications

Description. Applications CXH-EP PDS CXHEP Convection Explosion Proof Heater Electric Blower For Hazardous Locations Unit for Hazardous 3 to 35kW 10,200 to 119,420 BYU/Hour NORTH AMERICAN RATINGS 208 to 600 Volts 1.8 to 9.0kW (T-2A)

More information

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional Now available with optional ECM Motors High Efficiency / High Reliability Low rofile Unit Cooler ublication No. 100.14 January, 2008 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

EMI ENGINEERING SUBMITTAL

EMI ENGINEERING SUBMITTAL (MC2) MULTI-ZONE STRAIGHT COOL AIR CONDITIONING SYSTEMS Rev. 1.4 [4/05] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT

More information

Portable Vertical Air-Conditioning and Heating Systems

Portable Vertical Air-Conditioning and Heating Systems Portable Vertical Air-Conditioning and Heating Systems Specifications for 10 Ton Units 208 230 volt 7 1 77 77 77 33 Front Side Back 77 71 / 77 Front 33 Side 2 Cabinet Features: Heating and Cooling Data:

More information

bring value to your space

bring value to your space PTP unit heaters can use natural or propane gas, and are available in single-stage or optional two-stage controls. bring value to your space with THE NEW PTP HEATER. Introducing the new power vented, PTP

More information

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment

More information

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection Series PIC New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction and Renovation; Replaces

More information

Sum. Fan Switch. Wall FSW5III FSW5I II FSW5I 1 1 FSW51 II FSW5I 12 I-SW5I II FSW5I1I FSW5I11 FSW5I11 FSW5I11 FSW5I 1 1 FSW5II1 FSW5I 12 FSW

Sum. Fan Switch. Wall FSW5III FSW5I II FSW5I 1 1 FSW51 II FSW5I 12 I-SW5I II FSW5I1I FSW5I11 FSW5I11 FSW5I11 FSW5I 1 1 FSW5II1 FSW5I 12 FSW 2 Market s Company Recommended Control Options +FIF5I0N +HFIB5I0N +F2F50N + HI-2B5I0N +GIG50N PP5I0CAIN +FF5I05N -t-hflbslosn + F2F5HI5N + HI-2B505N +GIG5I05N PP5I05CAN F2FSIQ7CAL HI-2B5I07CAL GIG507CAL

More information

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts. EXUB Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts. Forced-Air Heater for Hazardous Locations Class I, Divisions 1 & 2, Groups

More information

UH Series Horizontal Fan Forced Unit Heater

UH Series Horizontal Fan Forced Unit Heater UH Series Horizontal Fan Forced Unit Heater 3.3 KW THROUGH 48 KW HORIZONTL DISCHRGE SUSPENDED FN FORCED UNIT HETERS VILLE IN 1 OR 3 PHSE FOR LL STNDRD VOLTGES FROM 8V TO 480V. Manufactured in U.S.. NOTE:

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES 1-year warranty on parts and labor. 5-year compressor warranty. If Registered a 10 year limited parts warranty applies. Designed for maximum

More information

Electric Heat - Air Curtains

Electric Heat - Air Curtains 06/09/13 A25-2 Electric Heat - Air Curtains Air Curtain - SDC Series Power High/Low (Watts) Volts Phase (nb.) Power High/Low (Btu/h) Ideal for commercial installations, this air curtain is very powerful!

More information

Heating Products M arch 2012

Heating Products M arch 2012 Heating Products M arch 2012 Broan Heaters Broan Heaters. Put the comfort you want right where it s needed. 2 Broan Heaters Why spot heating makes sense in your home. Think about it you hastily get ready

More information

( )

( ) (1-800-492-8826) www.wattco.com OVERVIEW WATTCO duct heaters are composed of open coil, tubular or finned tubular heating elements that are either flanged or inserted in the duct. WATTCO supplies two types

More information

(770) wwww.southgateprocess.com

(770) wwww.southgateprocess.com (770) 345-0010 wwww.southgateprocess.com OVERVIEW WATTCO duct heaters are composed of open coil, tubular or finned tubular heating elements that are either flanged or inserted in the duct. WATTCO supplies

More information

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions. MS Series UNIT COOLERS Technical Bulletin: MSUC_005_032 Products that provide lasting solutions. Medium Profile Units for Medium Size Walk-In Coolers and Freezers Access Panel Hinged panel cover provides

More information

Infrared Electric Heaters - General Product Information

Infrared Electric Heaters - General Product Information Infrared Electric Heaters - General Product Information 62 The largest selection of overhead electric infrared heaters in the industry today! Flat Panel Emitter Heaters High-density, medium wavelength

More information

Standard Duct Heaters Open Coil

Standard Duct Heaters Open Coil HUA Slip-In and HUP Flanged Heaters The 80% Rule HEATREX recommends the heater should occupy at least 80% of the actual inside area of the duct, as shown in Figure 45. Only small amounts of air will bypass

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers) WLCG/WLHG R-410A High-Efficiency Ductless Split System High-Wall Air Handlers Straight cool / Heat pump nominal capacities WLHG09 WLHG12 WLHG24 Units 9,000 12,000 18,000-23,800 Btuh 2.6 3.5 5.3-7.0 kw

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

Incremental Comfort Conditioners

Incremental Comfort Conditioners Style, comfort and energy efficiency...one room at a time. Incremental Comfort Conditioners Model PDNS Top-mounted Hydronic Heat Engineered for flexibility and performance PDNS Incremental Comfort Conditioners

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

UH Series Horizontal Fan Forced Unit Heater

UH Series Horizontal Fan Forced Unit Heater 3.3 KW THROUGH 15 KW UNIT HETERS KW THROUGH 48 KW UNIT HETERS HOW TO DESIGTE MODEL: H 2 H UH C 1 Element Volts F = 8 H = 0 HF = 0/8 G = 277 P = 480 UH Series Horizontal Fan Forced Unit Heater 3.3 KW THROUGH

More information

ELECTRIC UNIT HEATER UH SERIES

ELECTRIC UNIT HEATER UH SERIES ELECTRIC UNIT HEATER UH SERIES 3KW THRU 15KW INSTALLATION INSTRUCTIONS MODEL DESIGNATION SYSTEM EXAMPLE: H 1 H UH 15 C A 1 000 Volts Phase Motor Voltage Model Series Heater Wattage Mfg. Code Control Volts

More information

Cabinet Unit Heaters Steam / Hot Water

Cabinet Unit Heaters Steam / Hot Water 11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...

More information

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models July, 2009 Gas-Fired Power Vented Unit Heaters Propeller & Blower Models MODEL HD MODEL HDB MODEL PDP MODEL BDP TABLE OF CONTENTS Modine s power vented unit heaters are designed for the heating requirements

More information

STEAM/HOT WATER UNIT HEATERS

STEAM/HOT WATER UNIT HEATERS STEAM/HOT WATER UNIT HEATERS MODEL HSB/HC MODEL V/VN MODEL PT/PTN MODEL GLW FEBRUARY, 2015 Table of Contents Table of Contents Page I. Design Benefits A. Application, Design, Construction Overview...3

More information

Vertical V*B Series Fan Coil Technical Catalog

Vertical V*B Series Fan Coil Technical Catalog Vertical V*B Series Fan Coil Technical Catalog Vertical Hideaway (VCB) 200 CFM to 1200 CFM The Vertical Hideaway (VCB) fan coil unit is designed for concealed applications. The coil section is lined with

More information

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION OPERATION INSTALLATION PARTS MANUAL www.fostoriaindustries.com Made in U.S.A. ELECTRIC PORTABLE HEATER FES-1024-1CA 08860010 YES-1024-1CA 08861510 FES-1520-3A 08860110 YES-1520-3A 08860810 FES-1524-1A

More information

EXH Series Explosionproof Electric Air Heaters

EXH Series Explosionproof Electric Air Heaters EXH Series Electric Air Heaters Cl. I, Div. & 2, Groups C, D Cl. II, Div., Groups E, F, G NEMA 7CD, 9EFG EXH explosionproof electric heaters are used: In areas made hazardous by the presence of flammable

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions. SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_001_083115 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal

More information

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions. SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_005_040517 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal

More information

TABLE OF CONTENTS page 2

TABLE OF CONTENTS page 2 TABLE OF CONTENTS page 2 Metal Sheath Design... page 2 Mechanical Design...... page 3-7 Safety Protection...... page 7 Technical Design Data.....page 7 & 8 Temperature Control Guide...... page 8 Electrical

More information

Q-TEC QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner Cooling Capacities: 13,3 to 49,3 BTUH (Based on EWT, GPM & CFM) Q-TEC QC-Series Chilled Water Air Conditioner The Q-TEC Series self-contained packaged chilled water air conditioner is designed to be installed

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model DS4BD Series M120 Product Line High Efficiency R-410A Air Conditioner 13+ SEER 1.5-5 Ton Capacity 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise

More information

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages MODEL SE Commercial Electric Water Heater 6-119 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction High Efficiency Polyurethane

More information

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW MODEL V Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW Features Industrial Grade Construction Stainless steel pressure vessel provides maximum service

More information

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability- A Series Unit Coolers - Technical Catalog Product Benefits: T 3 $ Adaptability- Century systems go where others can t. Your Century system is engineered to meet your specific project application and job

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

Installation, Operation and

Installation, Operation and Installation, Operation and RENEWAL PARTS IDENTIFICATION DIVISION 4 SALES REFERENCE DATE SERVICE REFERENCE (Supersedes PF417-13) July, 2002 SECTION UB PF417-14 161-048445-001 Type UB-1002E, UB-1252E, UB-1502E,

More information

PTAC 2017 Air Conditioner Collection

PTAC 2017 Air Conditioner Collection PTAC 2017 Air Conditioner Collection PTAC COLLECTION The Frigidaire 2017 PTAC Collection offers flexibility for any application. Simple, intuitive controls and options, including remote thermostats, allow

More information

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS MODEL HD MODEL HDB MODEL HD MODEL HDB MODEL PDP MODEL BDP MODEL PTP 6-189.11 MAY, 2017 TABLE OF CONTENTS Modine s power vented unit heaters

More information

ELECTRIC UNIT HEATER REGULAR DUTY

ELECTRIC UNIT HEATER REGULAR DUTY ELECTRIC UNIT HEATER REGULAR DUTY Installation Form RGM 428 (MI500 Revision 0) APPLIES TO: Model EGE INDEX (by page number) Clearance to Combustibles... 3 Dimensions... 4 Electrical... 4 Fan Motor... 4

More information

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION CEILING FANS World Leader in Ceiling Fan Systems Visit our website at: www.marleymep.com Only Leading Edge Offers These Exclusive

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

Shipboard Electric Water Heater

Shipboard Electric Water Heater Marine Products Division Model MSE Shipboard Electric Water Heater 6-120 Gallon Capacity, Three Phase Voltages Up To 58 KW, Single Phase Voltages ver 6 KW Heavy Duty Construction n Hydrastone cement lining

More information

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations AEU1 Explosion-Proof Electric Air Heater For Hazardous Locations 0518 II 2G, Ex d IIB T4 Gb IP55 (ATEX) Ex d IIB T4 Gb IP55 (IECEx) 1ExdIIBT4 X IP55 (EAC Ex) (Suitable for ATEX/IECEx/EAC Ex Zone 1 & 2)

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information