1 COMMERCIAL MODELS: , CATALOG NO Effective: Replaces: RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 182, 260, 330, 400 ATMOSPHERIC 181, 261, 331, 401 LOW NOx MODEL TYPES: H AND WH DATES OF MANUFACTURE: THRU CURRENT MODELS H1, H5 & W2 FOR SIZES 182 & THRU THE PARTS LISTED ARE FOR STANDARD EQUIPMENT FOR THIS MODEL TYPE. RAYPAK RESERVES THE RIGHT TO SUBSTITUTE, DELETE OR CHANGE ANY PART WITHOUT NOTIFICATION. THE ADDITION OF OPTIONS MAY ALSO CHANGE SOME OF THE PARTS. ORDER REPLACEMENT PARTS FROM ACTUAL HEATER COMPONENTS. FOR DETAILED INSTRUCTIONS, SEE "HOW TO USE YOUR RAYPAK ILLUSTRATED PARTS LIST", CATALOG NO Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA (805) Fax (800) Litho In U.S.A. Part No

2 1-V 2-V 4-V 1-S 2-S 6-H 7-H 6-M 3-H 4-H 5-H 3-R 2-H 9-H 4-M 2-M 4-C 5-C 5-M 9-S 6-S 8-S 7-S 10-S 6-S 9-S 2-C 1-C 5-S 1-M 11-J 8-M 7-M 3-J 10-J 4-J 3-P 4-S 3-S 1-B 1-G 4-B 3-B 12-S 2-B 11-S 6-C 5-J 11-J 5-J 13-S 3-J 8-J 9-J 4-J 3-V 9-C 8-C

3

4 CALL OUT DESCRIPTION 182/ / / /401 B BURNER TRAY (Atmospheric)*** B Burner Tray w/burners (Sea Level)* F F F F Burner Tray w/o Burner (Sea Level)* F F F F 2-B Burner Spacer/Hold Down Kit F F F F 3-B Burner / / / /29 4-B Burner Orifice Nat. #51 (Sea Level)* F/ F/ F/ F/29 Burner Orifice Pro. #57 (Sea Level)* F/ F/ F/ F/29 5-B Burner Tray w/o Manifold and Burners F F F F BB BURNER TRAY (Fan Assisted Low Nox)*** BB Burner Tray w/burners (Sea Level)* F F F F Burner Tray w/ Burner 2 Stage (Sea Level)* F F F F Burner Tray w/o Burner (Sea Level)* F F F F Burner Tray w/o Burner 2 Stage (Sea Level)* F F F F 2-BB Burner Hold Down Kit F F F F 3-BB Burner F/ F/ F/ F/7 4-BB Burner Orifice Nat. #30 ( ft)** / / / /7 Burner Orifice Nat. #31 (Above 5000 ft)** / / / /7 5-BB Blower F F F F 6-BB Air Shutter On/Off F F F F Air Shutter 2 Stage F F F F C CONTROLS 1-C Manual Reset Adjustible High Limit 240 F Max F F F F Manual Reset Adjustible High Limit 200 F Max F F F F 2-C Auto Reset Adjustible High Limit 240 F Max F F F F Auto Reset Adjustible High Limit 200 F Max F F F F Auto Reset Adjustible High Limit 180 F Max F F F F 3-C Controller 2 Stage B F F F F Controller 2 Stage B-8 (W3 & WH3) F F F F Controller 4 Stage B-10 Digital (Use New #) N/A N/A N/A N/A Controller 4 Stage B-10 Digital Retrofit to B F F F F Controller 2 Stage (B-26 / B-27) Digital F F F F Controller 4 Stage (B-21 / B-23) Digital F F F F 7-C Controller 2 Stage w/ Outdoor Reset B F F F F 8-C Sensor Outdoor Air B F F F F 9-C Sensor Water Sensor Water System (Tekmar) F F F F Sensor Water screw-in Outlet (Tekmar) F F F F 4-C Flow Switch F F F F 5-C Flow Switch Paddle (McDonnell Miller) F F F F Flow Switch Paddle (Taco) F F F F 6-C Flame Roll-Out Sensor F F F F G GAS VALVE SEE GAS VALVE REPLACEMENT CHART H HEAT EXCHANGER 1-H Heat Exchanger Assy Cast Iron F F F F Heat Exchanger Assy Brass F F F F Heat Exchanger Assy Cast Iron Cupro Nickel F F F F Heat Exchanger Assy Brass Cupro Nickel F F F F 2-H Inlet/Outlet Header Cast Iron F F F F Inlet/Outlet Header Brass F F F F 3-H Return Header Cast Iron F F F F Return Header Brass F F F F 4-H Tube Bundle F F F F Tube Bundle Cupro Nickel F F F F 5-H Heat Exchange Tube F F F F Heat Exchange Tube Cupro Nickel F F F F 6-H Baffle Kit F F F F 7-H Stud Bolt Kit F F F F 8-H Header Gasket B B B B 9-H Sensor Well F F F F 10-H Well Retaining Clip *FOR ALTITUDES ABOVE 2,000 FEET LEVEL, CONSULT THE FACTORY **FOR INSTALLATIONS OVER 5000 FEET ABOVE SEA LEVEL, CONSULT THE FACTORY ***REPLACEMENT BURNER TRAYS ARE BUILT FOR SEA LEVEL, NATURAL GAS APPLICATIONS UNLESS OTHERWISE SPECIFIED AT THE TIME THE ORDER IS PLACED.

5 CALL OUT DESCRIPTION 182/ / / /401 J CONTROL BOX (Atmospheric) J Control Box IID/TTD (Not Shown) Water Heater Rated Units F F F F Boiler Rated Units manufactured prior to 9/1/ F F F F Boiler Rated Units manufactured from 9/1/ F F F F Control Box IID/TTD (H3) (Not Shown) Boiler Rated Units manufactured from 9/1/ F F N/A N/A Control Box Lock/TTD (Not Shown) Water Heater Rated Units F F F F Boiler Rated Units manufactured prior to 9/1/ F F F F Boiler Rated Units manufactured from 9/1/ F F F F Control Box Lock/TTD (H3, W3 & WH3) (Not Shown) Water Heater Rated Units F F F F Boiler Rated Units manufactured prior to 9/1/ F F F F Boiler Rated Units manufactured from 9/1/ F F F F 2-J Control Box C2A/TTD N/A N/A N/A N/A 3-J Transformer 120/24V 50VA F F F F 4-J Ignition Control IID B B B B Ignition Control Lock. IID B B B B Ignition Control IID/Damper F F N/A N/A Ignition Control Lock/Damper F F N/A N/A Ignition Control C2A F F F F 12-J Base Ignition Control F F F F 13-J Remote Keyboard Display Module C2A (Not Shown) F F F F 5-J Economaster II Control F F F F 6-J Amplifier Flame Rectification C2A (Not Shown) F F F F 7-J Spark Generator C2A (Not Shown) F F F F 8-J Relay SPST 24V Coil C2A F F F F 9-J Relay SPDT 120V Coil C2A F F F F Relay DPDT 120V NO/NC F F F F 11-J Toggle Switch F F F F J CONTROL BOX (Fan Assisted Low Nox) J Control Box IID On/Off (Not Shown) Water Heater Rated Units F F F F Boiler Rated Units manufactured prior to 9/1/ F F F F Boiler Rated Units manufactured from 9/1/ F F F F Control Box IID Two Stage (Not Shown) Water Heater Rated Units F F F F Boiler Rated Units manufactured prior to 9/1/ F F F F Boiler Rated Units manufactured from 9/1/ F F F F 2-J Control Box C2A/TTD N/A N/A N/A N/A 3-J Transformer 50VA F F F F 4-J Ignition Control IID B B B B Ignition Control Lock. IID B B B B Ignition Control IID/Damper F F N/A N/A Ignition Control Lock/Damper F F N/A N/A Ignition Control C2A F F F F 5-J Economaster II Control F F F F 6-J Amplifier Flame Rectification C2A (Not Shown) F F F F 7-J Spark Generator C2A (Not Shown) F F F F 8-J Relay SPST 24V Coil C2A F F F F 9-J Relay SPDT 120V Coil C2A F F F F Relay DPDT 120V NO/NC F F F F 10-J Relay Low Nox Blower F F F F Relay-10 Second Delay 2 Stage (Not Shown) F F F F 11-J Toggle Switch F F F F

6 CALL OUT DESCRIPTION 182/ / / /401 M MISCELLANEOUS COMPONENTS 1-M Switch Plate IID M PRV 30 PSI F F F F PRV 45 PSI F F F F PRV 60 PSI F F F F PRV 75 PSI F F F F PRV 125 PSI F F F F PRV 150 PSI F F F F 3-M Deliming Kit F F F F 4-M T & P Gauge 0-90 PSI F F F F T & P Gauge PSI F F F F T & P Gauge PSI F F F F 5-M Pump CIBF F F F F Pump Stainless/Brass F F F F 9-M Pump Cartridge F F F F 6-M Remote Sensor for Low Water Cut Off F F F F 7-M Low Water Cut Off PC Board F F F F 8-M Reset Switch for Low Water Cut Off F F F F 10-M Touch-up Paint Green Cool Dark Gray Warm Dark Gray P PILOT 1-P Pilot Nat. IID Atmospheric F F F F Pilot Pro. IID Atmospheric F F F F Pilot Nat. IID Low Nox F F F F Pilot C2 Nat F F F F 2-P Pilot Orifice Nat. IID F F F F Pilot Orifice Pro. IID F F F F Pilot Orifice Nat. C P Ignition Control IID B B B B Ignition Control Lock. IID B B B B Ignition Control IID/Damper F F N/A N/A Ignition Control Lock/Damper F F N/A N/A Ignition Control C2A (Not Shown) F F F F 4-P Pilot Mounting Bracket IID Atmospheric Pilot Mounting Bracket C2 Atmospheric F F F F 5-P Pilot Mounting Bracket IID Low Nox F F F F Pilot Mounting Bracket C2 Low Nox F F F F 6-P Pilot Tube P Hi Tension Wire w/pilot Electrode N/A N/A N/A N/A 8-P Base Ignition Control C2 (Not Shown) F F F F R REFRACTORY 1-R Refractory Common (Left & Right) F F F F 2-R Refractory Uncommon (Front & Rear) F F F F 4-R Refractory (All) F F F F 3-R Refractory Retainer Kit F F F F

7 CALL OUT DESCRIPTION 182/ / / /401 S SHEETMETAL 1-S Jacket Top (Louvered) Green F F F F Cool Dark Gray F F F F 2-S Flue Collector F F F F 3-S Door Assy. Green F F F F Warm Dark Gray F F F F 4-S Screw & Retainer F F F F 5-S Control Panel Green F F F F Warm Dark Gray F F F F 6-S Access Panel Green F F F F Cool Dark Gray F F F F 7-S Side Panel Right Green F F F F Cool Dark Gray F F F F 8-S Side Panel Left Green F F F F Cool Dark Gray F F F F 9-S Side Panel Cap Green F F F F Cool Dark Gray F F F F 10-S Rear Panel Kit (2 Pcs.) Green F F F F Cool Dark Gray F F F F 11-S Sub-Base for Combustible Flooring S Outdoor Base Green Cool Dark Gray S J-Box Sheet Metal C2A F F F F V VENTING 1-V Draft Hood Kit V Flue Gas Spillage Temp Sensor F F N/A N/A 3-V Stack Adapter (Includes Outer Adapter Panel) Green F F F F Cool Dark Gray F F F F 4-V "Pagoda" Top Green Cool Dark Gray V Vent Damper (Not Shown) N/A N/A GAS VALVES* PART H1 H5 & W2 NUMBER 182A 260A 330A 400A 182A 260A 330A 400A 1-G MODULATING GAS VALVES Valve 3/ Nat F X X X Valve 3/ Pro F X X X Valve 3/ Nat F X X X Valve 3/ Pro F X X X Valve 1" Nat F X Valve 1" Pro F X Valve 1" Nat F X Valve 1" Pro F X Solenoid Coil F X X X X X X X X AUTOMATIC GAS VALVES (Atmospheric) H3, W3 & WH3 H4, W1 & WH1 Valve - Gas On/Off (NAT) F X X X X Valve - Gas On/Off (PRO) F X X X X Valve - Gas Two Stage 3/4" (NAT) RS F X X X Valve - Gas Two Stage 1" (NAT) RS F X Valve - Gas Two Stage 3/4" (NAT) HW F X X X X Valve - Gas Two Stage (PRO) RS F X X X X Valve - Gas Two Stage 3/4" (PRO) HW F X X X X H3, W3 & WH3 H4, W1 & WH1 2-G AUTOMATIC GAS VALVES (Fan Assisted Low Nox) 181A 261A 331A 401A 181A 261A 331A 401A Valve - Gas On/Off (NAT) F X X X X X X X X Valve - Gas On/Off (Solenoid Stage 2) F X X X X *For gas conversions, consult the factory.

8

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST RAYPAK ILLUSTRATED PARTS LIST The parts listed are for standard equipment for this model type. Raypak reserves the right to substitute, delete or change any part without notification. The addition of options

More information

COMMERCIAL MODELS: XTHERM 1005 THROUGH 2005

COMMERCIAL MODELS: XTHERM 1005 THROUGH 2005 COMMERCIAL MODELS: XTHERM 1005 THROUGH 2005 CATALOG NO. 9300.742 Effective: 08-05-10 Replaces: 09-29-09 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 1005, 1505 & 2005 MODEL TYPES: MODULATING VERTICAL BOILER

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS DELTA LIMITED, TYPE WH - MODELS 399B-899B SUGGESTED SPECIFICATIONS Catalog No.: 3500.97B Effective: 04-01-17 Replaces: 11-15-08 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY

More information

Hayward Heaters. Hayward H-Series 100,000 BTU Heater (H100ID1 & H100IDP1)

Hayward Heaters. Hayward H-Series 100,000 BTU Heater (H100ID1 & H100IDP1) Hayward Heaters Hayward H-Series 100,000 BTU Heater (H100ID1 & H100IDP1) 1165 Hayward Heaters Hayward H-Series 100,000 BTU Heater (H100ID1 & H100IDP1) W000043.00 l IDXJKT1100 1 Jacket Top $86.00 NLA IDXBWR1935

More information

2017 Parts Catalog. Hayward H-Series 100,000 BTU Heater (H100ID1 & H100IDP1) Pricing Effective Hayward Heaters

2017 Parts Catalog. Hayward H-Series 100,000 BTU Heater (H100ID1 & H100IDP1) Pricing Effective Hayward Heaters Hayward Heaters Hayward H-Series 100,000 BTU Heater (H100ID1 & H100IDP1) 1165 Hayward Heaters Hayward H-Series 100,000 BTU Heater (H100ID1 & H100IDP1) W000044.80 IDXJKT1100 1 Jacket Top $89.60 NLA IDXBWR1935

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS HI DELTA, TYPE WH - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 3500.932A Effective: 04-01-17 Replaces: 10-31-16 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY A.

More information

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than. s 504 thru 2004 Category I with vertical vent s 503 thru 2003 Category IV Venting Up to 88.4% thermal efficiency! CSA Certified Lead Content Less Than.25 Pb Category I*-up to 85% efficiency Category IV-up

More information

15B Cast Iron Gas Fired Boilers For Forced Hot Water

15B Cast Iron Gas Fired Boilers For Forced Hot Water Models 5B05FE 5B070FE 5B0FE 5B0FE 5B5FE 5B70FE 5B5FE 5B5FE 5B5FE 5B Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest

More information

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS HI DELTA, TYPE P - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 6000.611 Effective: 10-31-16 Replaces: NEW FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired,

More information

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS HI DELTA, TYPE P - MODELS 502C-902C SUGGESTED SPECIFICATIONS Catalog No.: 6000.601A Effective: 07-12-18 Replaces: 10-31-16 FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired,

More information

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES Models BWBBAN00005 BWBBAN000070 BWBBAN00006 BWBBAN0000 BWBBAN0005 BWBBAN00070 BWBBAN0005 BWBBAN0005 BWBBAN0005 Ordering Instructions

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 2505-4005 SUGGESTED SPECIFICATIONS Catalog No.: 6000.70 Effective: 09-15-16 Replaces: NEW WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes condensing, gas-fired

More information

Boiler & Water Heater

Boiler & Water Heater MIGHTY THERM2 Date: Project #: Pump-Mounted Boiler & Water Heater MT2H Hydronic Heater MT2V Volume Water Heater Indoor/Outdoor Sizes 500-2000 Submittal Engineer: Project Name: Prepared By: Location: Bid

More information

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES Models BWBAAN0000 BWBAAN000070 BWBAAN0000 BWBAAN0000 BWBAAN000 BWBAAN00070 BWBAAN000 BWBAAN000 BWBAAN000 Ordering Instructions

More information

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Models 1005, 1505, 2005 Up to 99% thermal efficiency! Models 1005, 1505, 2005 Up to 99% thermal efficiency! Can be vented with PVC pipe - D32 Option or Centrotherm Polypropylene (D-33) Proudly made in the U.S.A Xtreme Performance Up to 99% thermal efficiency!

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 1005A-2005A SUGGESTED SPECIFICATIONS Catalog No.: 6000.63B Effective: 3-01-15 Replaces: 9-01-09 WATER-TUBE POOL HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes condensing,

More information

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS XTHERM, TYPE WH - MODELS 1005A- 2005A Catalog No.: 3500.801 Effective: 11-15-14 Replaces: NEW PART 1 - GENERAL 1.1 SUMMARY DIVISION 23 34 36.29 COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

More information

Quantity X Section Assembly (Intermittent and Continuous Circulation Only)

Quantity X Section Assembly (Intermittent and Continuous Circulation Only) V. Repair Parts Section Assembly and Canopy Group...30 Base Assembly...3 Manifold and Main Burners Inch Main Burners...34 40mm Main Burners...36 Pilot Burner and Gas Valve Continuous Ignition (Standing

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 2000.932C Effective: 04-01-14 Replaces: 07-15-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32 Models 1005, 1505, 2005 Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32 Xtreme Performance Up to 99% thermal efficiency! Think Green Think Raypak Raypak s Next Generation Condensing

More information

PENTAIR/PUREX TROPIC ISLE HEATER

PENTAIR/PUREX TROPIC ISLE HEATER PENTAIR/PUREX TROPIC ISLE HEATER Heaters H-77 PRIMARY COMPONENTS ONLY (1988-) Indoor/Outdoor Stack Top A-C Outdoor Top HEAT EXCHANGER INCLUDES TUBE BUNDLE ONLY NO HEADER GASKETS, NUTS, OR BOLTS NUMBER

More information

DXL SERIES II CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER

DXL SERIES II CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER Models DXL-0 DXL-7 DXL-00 DXL- DXL-0 DXL-70 DXL-00 DXL SERIES II CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER REPAIR PARTS AND OPTIONAL KITS Ordering Instructions Order Parts through your nearest supplier.

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS HI DELTA, TYPE H - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 2000.953 Effective: 10-31-16 Replaces: NEW DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS - GENERAL 1.1 SUMMARY A. Section includes

More information

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A. ULTRA HIGH EFFICIENCY VERSA IC Platform with Touch Screen Models 1005A, 1505A, 2005A 2505, 3005, 3505, 4005 Up to 99% thermal efficiency! Proudly assembled in the U.S.A. Xtreme Performance Up to 99% thermal

More information

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective Commercial Water Heater Replacement Parts Price List For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB Prices Effective October 2, 2006 This parts price catalog supercedes book number SCBPB00306 and all

More information

Replacement Parts List For Models COS-20G

Replacement Parts List For Models COS-20G Replacement Parts List For Models COS-20G (Ovens with s/n HP & HT) Contents: Page # Electrical Compartment:Contactors,Steam Generator,Thermostats 2-5 Oven Interior: 5 Bottom Section: Gas, Plumbing Components

More information

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS MVB, TYPE WH - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 3500.952C Effective: 06-25-15 Replaces: 12-22-09 DIVISION 23 34 36.29 COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

More information

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY ULTRA HIGH EFFICIENCY Touch Screen VERSA IC Control Platform Models 1005A, 1505A, 2005A 2505, 3005, 3505, 4005 Up to 99% thermal efficiency! Proudly assembled in the U.S.A. Xtreme Performance Up to 99%

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 2503-4003 SUGGESTED SPECIFICATIONS Catalog No.: 2000.934A Effective: 04-01-14 Replaces: 06-01-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

13.2 Component Illustrations, Parts Lists, and Part Numbers

13.2 Component Illustrations, Parts Lists, and Part Numbers Page 0 LAARS Heating Systems Section REPLACEMENT PARTS Use only genuine LAARS replacement parts.. General Information To order or purchase parts for the LAARS MagnaTherm Appliance, contact your nearest

More information

Figure 10 or Figure 6

Figure 10 or Figure 6 SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-45637-00 and 238-48933-00 (Replaces pg. 32 (238-45637-00) or pg. 28 (238-48933-00) in Wiring Diagram Honeywell A B C VERY HO HO LOW Figure 10 or Figure 6 238-48214-00B

More information

Ultra Boiler Series 1 & 2 Jacket Parts

Ultra Boiler Series 1 & 2 Jacket Parts GAS Ultra Boiler Series 1 & 2 Jacket Parts 9 10 8 6 7 1 5 2 3 Fig. Part Description Model Mfr. 1 383-500-135 Jacket Front Door 595-000-000 595-000-001 595-000-002 595-000-003 Panel Door Jacket Plastic

More information

Raypak Residential Products

Raypak Residential Products Raypak Residential Products Raypak s Residential Boiler Product Family Raypak revolutionized the boiler market in 1948 with the first innovative high recovery boilers that utilized superior finned copper

More information

Effective february 9, 2015

Effective february 9, 2015 BDO-G CONVECTION OVEN REPLACEMENT PARTS LIST Effective february 9, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are not

More information

Less Than.25% Lead Proudly Assembled in the U.S.A

Less Than.25% Lead Proudly Assembled in the U.S.A Versa IC Control Platform Models 504A thru 2004A Category I with vertical vent Models 503A thru 2003A Models 2503 thru 4003 Category IV Venting Up to 88.4% thermal efficiency! CSA Certified Lead Content

More information

Less Than.25 Pb Proudly made in the U.S.A

Less Than.25 Pb Proudly made in the U.S.A New Versa IC TM Control Platform Models 504A thru 2004A Category I with vertical vent Models 503A thru 2003A Models 2503 thru 4003 Category IV Venting Up to 88.4% thermal efficiency! CSA Certified Lead

More information

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

Multiple Heater Controller TempTracker Mod+, up to 16 heaters WHP HEAT EXCHANGER JACKET OTHER GAS TRAIN SAFETIES OPERATING CONTROLS ASME, National Board Registered, 160 PSI HLW Stamp Heat Exchanger Tubes Cupro Nickel Bronze Headers Stainless Steel Condensing Heat

More information

Effective october 14, 2014

Effective october 14, 2014 COS-20G combi oven-steamer REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified

More information

All repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change

All repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change Gas Valve and Pilot, Standing Pilot Gas Valve and Pilot, Intermittent Ignition, Natural Gas Gas Valve and Pilot, Intermittent Ignition, Current 52 Parts To Your Door Repair Parts List (R-18) Effective

More information

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. General: 1. To obtain maintenance and repair standards for boiler burners (Section 15555A) and boiler tubes (Section 15555B), contact the DPS Project

More information

Proudly assembled in U.S.A

Proudly assembled in U.S.A s HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb Proudly assembled in U.S.A Up to 85% thermal efficiency! Raypak s Decades of expertise and technological innovations went into creating

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 504A-2004A SUGGESTED SPECIFICATIONS Catalog No.: 2000.933C Effective: 06-25-15 Replaces: 12-21-09 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS USERS INFORMATION MANUAL FOR GAS FIRED BOILERS CATALOG NO.: 2000.52G Effective: 06-01-00 Replaces: 07-01-94 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result

More information

B-14G. for series number with jm or j

B-14G. for series number with jm or j B-G boilerless steamer REPLACEMENT PARTS LIST for series number with jm or j Effective june, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that

More information

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead. VERSA IC Control Platform up to99% Efficiency! Can be vented with: PVC, Centrotherm Polypropylene or Stainless Steel. MBTU s 300A 400A 500A 700A 850A CSA Certified Low Lead Content Less Than.25% Lead Ultra

More information

Less Than.25% Lead Proudly Assembled in the U.S.A

Less Than.25% Lead Proudly Assembled in the U.S.A Touch Screen Versa IC Control Models 504A thru 2004A Category I with vertical vent Models 503A thru 2003A Models 2503 thru 4003 Category IV Venting Up to 88.4% thermal efficiency! CSA Certified Lead Content

More information

FSB Series II Gas-Fired Hot Water Induced Draft Boilers

FSB Series II Gas-Fired Hot Water Induced Draft Boilers FSB Series II Gas-Fired Hot Water Induced Draft Boilers Models FSB- FSB-3 FSB-4 FSB-5 FSB-6 FSB-7 REPAIR PARTS AND OPTIONAL KITS Ordering Instructions Order Parts through your nearest supplier. When ordering

More information

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A New VERSA IC Control Platform Models 1005A, 1505A, 2005A Up to 99% thermal efficiency! Can be vented with PVC pipe - D32 Option or Centrotherm Polypropylene (D-33) Proudly made in the U.S.A Xtreme Performance

More information

Proudly assembled in U.S.A

Proudly assembled in U.S.A Versa IC Control System s 302C thru 2342C CSA certified Low Lead Content Less Than -.25% Lead Proudly assembled in U.S.A Up to 84% thermal efficiency! Raypak s Decades of expertise and technological innovations

More information

Proudly assembled in U.S.A

Proudly assembled in U.S.A UP TO 85% THERMAL EFFICIENCY Versa IC Control System s 302C thru 2342C CSA certified Low Lead Content Less Than -.25% Lead Proudly assembled in U.S.A Up to 85% thermal efficiency! Raypak s Decades of expertise

More information

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content New Versa IC TM Control Platform up to 99% Efficiency! Can be vented with: PVC, Centrotherm Polypropylene or Stainless Steel. MBTU s 300A 400A 500A 700A 850A CSA Certified Low Lead Content Less Than.25%

More information

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS XPAK FT TYPE H - MODELS 088AR-398A SUGGESTED SPECIFICATIONS Catalog No.: 2100.91 Effective: 05/01/15 Replaces: new DIVISION 23 52 33.13 WALL-HUNG STAINLESS STEEL HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY

More information

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support: At Bradford White, we believe in giving you a feature-packed, premium product at the best possible price. We proudly build quality and value into each and every product we manufacture. We believe when

More information

Models HD101 thru 2342B

Models HD101 thru 2342B s HD101 thru 2342B Up to 87% thermal efficiency! Raypak s Decades of expertise and technological innovations went into creating the boiler, a product that incorporates features sought after by engineers,

More information

All repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change

All repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change Gas Valve and Pilot Standing Pilot (Continuous Ignition) Gas Valve and Pilot Intermittent Ignition 26 Parts To Your Door Repair Parts Trade Price List (R-16) Effective June 1, 2016 Description Quantity

More information

Econopak Water Heaters

Econopak Water Heaters INSTALLATION & OPERATING INSTRUCTIONS Econopak Water Heaters Models 0260 0401 Type WH WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property

More information

ZEPHAIRE-100-G-ES AND ZEPHAIRE-200-G-ES CONVECTION OVEN REPLACEMENT PARTS LIST

ZEPHAIRE-100-G-ES AND ZEPHAIRE-200-G-ES CONVECTION OVEN REPLACEMENT PARTS LIST ZEPHAIRE-00-G-ES AND ZEPHAIRE-00-G-ES CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE FEBRUARY, 0 Superseding All Previous s Lists. The Company reserves the right to make substitution in the event that

More information

SERVICE TECHNICIAN ONLY read and follow completely.

SERVICE TECHNICIAN ONLY read and follow completely. Parts list Table 7 Series 3 section and flue collector parts Item Description Part No. A Wide front section (7011) 316-700-245 B C D E Regular intermediate section (7015) Intermediate section w/draw rod

More information

DFG-100-ES and DFG-200-ES

DFG-100-ES and DFG-200-ES DFG-00-ES and DFG-00-ES CONVECTION OVEN REPLACEMENT PARTS LIST Effective june, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified

More information

High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS. P/N# , Rev. C [01/09]

High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS. P/N# , Rev. C [01/09] High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS P/N# 240007518, Rev. C [01/09] JACKET 3 5 8 10 7 9 4 6 1 11 Key Description 4 section 5 section 6 section 7 section Complete Jacket

More information

Replacement Parts List

Replacement Parts List Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Copper-Fin Boilers Water Heaters CB CW 987-2067 52 21 18

More information

84 PROFESSIONAL - IN A CATEGORY ALL ITS OWN

84 PROFESSIONAL - IN A CATEGORY ALL ITS OWN 84 Professional 84 PROFESSIONAL - A CATEGORY ALL ITS OWN MICROPROCESSOR control is more precise than mechanical systems. It controls temperatures for pool and spa settings and stores diagnostic information

More information

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists. Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part of replacement part. Results

More information

MASTERTEMP HEATER REPLACEMENT PARTS

MASTERTEMP HEATER REPLACEMENT PARTS 0 Section. Maintenance/Replacement Parts Electrical System (Key Nos. through 4), See Page 2 Burner System (Key Nos. through ), See Page 4 Water System (Key Nos. through ), see Page 2 Repair Parts are available

More information

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS LCD-5 INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS The LCD Dominator Series from RBI offers competitively-priced indoor/outdoor units that meet low NOx requirements, while maintaining

More information

CG Section and Base Assembly Series 1 through 12

CG Section and Base Assembly Series 1 through 12 GAS CG Section and Base Assembly Series through 2 5 3 2 2 3 4 9 6 8 0 8B 0A 7 22 Discontinued Service Parts CG Section and Base Assembly Series through 2 GAS Fig. No. Part No. Description Series No. 3-03-85

More information

SERIES 19A. mith PRESSURIZED WET BASE

SERIES 19A. mith PRESSURIZED WET BASE SERIES 19A mith series19a BOILER/BURNER PRESSURIZED WET BASE UNIT series 19A STANDARD EQUIPMENT All s Cast iron wet-base sections tested for 80psi. Insulated metal jacket Cast iron smokehood with integral

More information

Models HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb. Proudly made in U.S.A

Models HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb. Proudly made in U.S.A s HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb Proudly made in U.S.A Up to 87% thermal efficiency! o~óé~âûë=eá=aéäí~ Decades of expertise and technological innovations went into creating

More information

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters Low NOx, Quiet, Efficient, Space-Saving Mighty Therm Lo-NOx Greater energy efficiencies as high as 84% are achieved through

More information

WF WAVE SERIES: WF 42 AND WF 60 PIZZA OVENS REPLACEMENT PARTS LIST

WF WAVE SERIES: WF 42 AND WF 60 PIZZA OVENS REPLACEMENT PARTS LIST WF WAVE SERIES: WF AND WF 0 PIZZA OVENS REPLACEMENT S LIST EFFECTIVE MAY, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are

More information

GAS RESTAURANT RANGE MODELS 24L, 36L/LC, 48L, 481L/LC, 148L/LC, 60 L/LC/LCC, 160L/LC, 260L/LC/LCC

GAS RESTAURANT RANGE MODELS 24L, 36L/LC, 48L, 481L/LC, 148L/LC, 60 L/LC/LCC, 160L/LC, 260L/LC/LCC CATALOG OF REPLACEMENT PARTS GAS RESTAURANT RANGE MODELS 24L, 36L/LC, 48L, 481L/LC, 148L/LC, 60 L/LC/LCC, 160L/LC, 260L/LC/LCC MODEL 24L 36L/LC 48L 481L/LC 148L/LC 60L/LC/LCC 160L/LC 260L/LC/LCC ML-52947

More information

Power Direct Vent PDV(S&T) Models

Power Direct Vent PDV(S&T) Models COMMERCIAL REPLACEMENT PARTS LIST Power Direct Vent PDV(S&T) Models Includes Hydrojet Total Performance System Effective: January, 2012 ECO 7731 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING

More information

Columbia Boiler Company

Columbia Boiler Company EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net

More information

BC14G SERIES SERIAL NUMBERS WITH IW/IX/IZ/JG/JO REPLACEMENT PARTS LIST. EFFECTIVE March 20, 2006

BC14G SERIES SERIAL NUMBERS WITH IW/IX/IZ/JG/JO REPLACEMENT PARTS LIST. EFFECTIVE March 20, 2006 BCG SERIES SERIAL NUMBERS WITH IW/IX/IZ/JG/JO REPLACEMENT PARTS LIST EFFECTIVE March 0, 00 BLODGETT OVEN COMPANY, Lakeside Avenue, Burlington, Vermont 050 USA Telephone: (0) 0-700 (00) -5 Fax: (0) 0-7

More information

NO ONE PUTS MORE INTO THEIR POOL HEATERS

NO ONE PUTS MORE INTO THEIR POOL HEATERS 84 Professional NO ONE PUTS MORE TO THEIR POOL HEATERS Introducing the Raypak 84 Professional series pool heater, designed specifically for commercial properties such as apartments, condos, hotels, motels,

More information

Replacement parts EG/PEG

Replacement parts EG/PEG Replacement parts EG/PEG Table 13 EG/PEG replacement parts A B Left hand end section with heater opening (Pattern No. 1814) Left end section without heater opening(pattern No. 1813) Right hand end section

More information

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE: www.weil-mclain.com COMMERCIAL GAS OILER Series Gas Water or Steam MH: 400-,860 Efficiency 85.% Net Load Range: Hot Water 80-, MH / Steam 975-7,40 Sq. Ft. COMMERCIAL GAS OILER APPLICATIONS INCLUDE: Apartment

More information

Model SSV-399 GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

Model SSV-399 GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES Model SSV-399 GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model Number and Serial Number from data plate on

More information

/13 Price - $5.00

/13 Price - $5.00 INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR ALPINE CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT WATER BOILER 9700609 As an ENERGY STAR Partner, U.S. Boiler Company has determined that

More information

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

Series 8H. Cast Iron Gas Fired Commercial Water Boiler Series 8H Cast Iron Gas Fired Commercial Water Boiler to 0 MBH Input Over 8% Efficient 0 or 0 PSI Cast Iron Sectional Design Atmospheric Vent Modular/Multiple Boiler Configurations Available Series 8H

More information

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS FTIIC-6 LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS Futera II Series boilers and water heaters are also available with corrosion-resistant, brushed stainless steel jacket. Ideal

More information

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions up to 99% Efficiency! Can be vented with PVC MBTU s 300 400 500 700 850 CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions Xtreme Outdoor Performance Up to 99% part load! XFyreT Condensing

More information

NO ONE PUTS MORE INTO THEIR POOL HEATERS

NO ONE PUTS MORE INTO THEIR POOL HEATERS NO ONE PUTS MORE INTO THEIR POOL HEATERS Introducing the Raypak Professional series pool heaters, designed specifically for commercial properties such as apartments, condos, hotels, motels, schools, parks,

More information

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists. gas-fired water boiler Manual Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part

More information

SWIMMING POOL & SPA HEATER D-2

SWIMMING POOL & SPA HEATER D-2 INSTALLATION & OPERATING INSTRUCTIONS SWIMMING POOL & SPA HEATER -2-2 POWER VENT 206A, 207A, 266A, 267A, 268 336A, 337A, 406A, 407A, 408 (ELECTRONIC IGNITION MOELS ONLY) WARNING: If these instructions

More information

SWIMMING POOL & SPA HEATER D-2

SWIMMING POOL & SPA HEATER D-2 INSTALLATION & OPERATING INSTRUCTIONS SWIMMING POOL & SPA HEATER -2-2 POWER VENT 206A, 207A, 266A, 267A, 336A, 337A, 406A, 407A (ELECTRONIC IGNITION MOELS ONLY) WARNING: If these instructions are not followed

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts Figure 92 Propane conversion kits and instructions Boiler model DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE The WM97+ maintenance kit includes components that

More information

Rheem Digital gas heater

Rheem Digital gas heater Self-Diagnostic Se n s o r F a i l u r e Remote-Compatible Re m o t e W a t e r Po o l Te m p Run Time and Cycle Meter Ru n T i m e 1 0 0 h C y c l e s 134 Flame Strength Indicator Fl a m e 104F 6 9 F

More information

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A Table of Contents Part Number Index MANUFACTURER Page MANUFACTURER Page 1 1271A 1271B -211-B15 182EA 2 220736B 5 5/8X10RL 5/8X12RL 5/8X18RL 5/8X24RL 5/8X36RL 5/8X48HDRL 5/8X60RL 6 CONBRACO 6012 WHEELER

More information

SECTION HEATING BOILERS

SECTION HEATING BOILERS SECTION 23 52 00 HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes boilers, controls and boiler trim, steam and condensate connections, hot water connections, fuel burning system and connections,

More information

REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF "A" Series 15 SEER Models

REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF A Series 15 SEER Models REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF "A" Series 15 SEER Models IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper repair

More information

DFG-100 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST

DFG-100 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST DFG-00 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE JANUARY, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified

More information

Parts Lists with Exploded Views

Parts Lists with Exploded Views Parts Lists with Exploded Views Strip, Filler (Island Trim) 0 Hinge, Door Stiffener Support Assy LH Trim, Center Post, 0" Panel, Door 0 W/O Logo *Special Order, Call Factory Parts Department Door, Oven

More information

OPERATING AND INSTALLATION INSTRUCTIONS Models

OPERATING AND INSTALLATION INSTRUCTIONS Models OPERATING AND INSTALLATION INSTRUCTIONS Models 136-1826 CATALOG NO.: RM-001 Effective : 01-15-02 Replaces: 03-15-01 MODEL SERIAL NUMBER INSTALLATION DATE START UP DATE FOR YOUR SAFETY Do not store or use

More information

C-Spa XI Models

C-Spa XI Models C-Spa XI Models. -. - HEATER REPLACEMENT PARTS Parts Diagram 9 9 6 0 3 6 8 3 0 8 6 3 HAYWARD C-Spa XI Models. -. - HEATER REPLACEMENT PARTS Parts Listing Ref. No. Part No. Description Ref. No. Part No.

More information

Now Available as a Mobile App:

Now Available as a Mobile App: Tool Box Quick Reference Guide Raypak/Rheem Digital Gas Pool Heaters Now Available as a Mobile App: WATER CHEMISTRY (Corrosive water voids all warranties) For your health and the protection of your pool

More information

DFG-100 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST

DFG-100 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST DFG-00 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE MARCH 00 BLODGETT OVEN COMPANY, Lakeside Avenue, Burlington, Vermont 00 USA Telephone: (0) 0-00 (00) - Fax: (0) 0- www.blodgett.com

More information

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent HHA Lyerly Apartments 75 Lyerly Houston, Texas 77022 J. Allen Management Managing Agent Scope of Work: 1.) Boiler Replacement with Double Vertical Boiler System (1 Million btu each) 2.) Water Pump Replacement

More information

HOT WATER BOILER ( MBH)

HOT WATER BOILER ( MBH) GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER (25-200 MBH) Repair PARTS MANUAL P/N 24000523, Rev. C [09/08] TABLE OF CONTENTS I. Circulator Pumps (Optional)...2 II. Burner Assembly...3 III. Boiler

More information

Heater Selection Guide SELECTING THE CORRECT SIZE HEATER FOR POOLS & SPAS

Heater Selection Guide SELECTING THE CORRECT SIZE HEATER FOR POOLS & SPAS Heater Selection Guide SELECTING THE CORRECT SIZE HEATER FOR POOLS & SPAS Pool Sizing Determine your pool s surface area in square feet: Locate in the desired table below, the surface area equal to or

More information