Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Size: px
Start display at page:

Download "Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid."

Transcription

1 HEAT EXCHANGERS

2 Heat Exchanger Heat exchanger is an apparatus or an equipment in which the process of heating or cooling occurs. The heat is transferred from one fluid being heated to another fluid being cooled. OR Heat exchanger is process equipment designed for the effective transfer of heat energy between two fluids; a hot fluid and a coolant. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

3 Heat Exchanger Examples of Heat exchangers are: Boilers, Evaporators, Heaters and Condensers Boilers Evaporators Condensers

4 Heat Exchanger Examples of Heat exchangers are: Automobile radiators and oil coolers of heat engines Automobile radiator Oil Coolers

5 Heat Exchanger Examples of Heat exchangers are: Condensers and evaporators in refrigeration units Water and air heaters or coolers Air Heaters

6 Heat Exchanger Heat transferred in the heat exchanger may be in the form of latent heat (e.g. in boilers and condensers) or sensible heat (e.g. in heaters and coolers)

7 Classification of Heat Exchangers 1. Nature of heat exchange process Direct contact heat exchanger Indirect contact heat exchanger Regenerator Recuperator 2. Relative direction of motion of fluid Co-current (Parallel) flow Counter-current (Counter) flow Cross flow

8 Classification of Heat Exchangers 3. Design and constructional features (Mechanical design of heat exchange surface) Concentric tubes Shell and tube Multiple shell and tube passes Compact heat exchangers 4. Physical state of heat exchanging fluids (condensation and evaporation) Condenser Evaporator

9 Classification of Heat Exchangers 1. Nature of heat exchange process Direct contact heat exchanger In a direct contact or open heat exchanger the exchange of heat takes place by direct mixing of hot and cold fluids and transfer of heat and mass take place simultaneously. Direct contact or open heat exchanger

10 Classification of Heat Exchangers The use of such units is made under conditions where mixing of two fluids is either harmless or desirable. Examples: Cooing towers, Jet condensers, direct contact feed heaters

11 Classification of Heat Exchangers 1. Nature of heat exchange process Indirect contact heat exchanger In this type of heat exchanger, the heat transfer between two fluids could be carried out by transmission through wall which separates the two fluids. This type includes the following: (a) Regenerator (b) Recuperators or surface exchangers

12 Classification of Heat Exchangers 1. Nature of heat exchange process Indirect contact heat exchanger (a) Regenerator The regenerator are those devices in which hot and cold fluids alternately flow over the surface (through a space containing solid particles (matrix)). The heat carried by the hot fluid is accumulated in the walls of the equipment and is then transferred to the cold fluid when it passes over the surface next.

13 Regenerator Rotating Matrix Regenerator Fig shows a cylinder containing a matrix that rotates in such a way that it passes alternately through cold and hot gas streams which are sealed from each other.

14 Regenerator Fig. shows a stationary matrix regenerator in which hot and cold gases flow through them alternately. Stationary Matrix Regenerator

15 Regenerator Examples: I.C. engines and gas turbines, Open hearth and glass melting furnace, air heaters of blast furnace A regenerator generally operates periodically (wall or solid matrix alternately stores heat extracted from the hot fluid and then delivers it to the cold fluid). In some regenerators the matrix is made rotate through the fluid passages arranged side by side which makes the heat exchange process continuous.

16 Regenerator The performance of these regenerators is affected by Heat capacity of regenerating material The rate of absorption The release of heat

17 Regenerator Advantages of Regenerators Higher heat transfer coefficient Less weight per kw of the plant Minimum pressure drop Quick response to load variation Small bulk weight Efficiency quite high

18 Regenerator Dis-advantages of Regenerators Costlier compared to recuperative heat exchanger Leakage is the main trouble, therefore perfect setting is required.

19 Classification of Heat Exchangers 1. Nature of heat exchange process Indirect contact heat exchanger (b) Recuperator Most common heat exchangers are the recuperators in which both hot and cold fluids separated from each other by a wall, flow through the exchanger at the same time. The heat transfer process consists of convection between the fluid and wall, conduction through the wall and convection between the wall and other fluid. In case the T between wall and fluid is large, radiation heat exchange may also occur.

20 Recuperator Such exchangers are used where the cooling and heating fluids can not be allowed to mix. Examples: Automobile radiators Oil coolers, intercoolers, air preheaters, economizers, super heaters, condensers and surface feed heaters of a steam power plant Milk chiller of pasteurizing plant Evaporator of ice plant

21 Recuperator Advantages of Recuperators Easy construction More economical More surface area for heat transfer Much suitable for stationary plants

22 Recuperator Dis-advantages of Recuperators Less heat transfer coefficient Less generating capacity

23 Classification of Heat Exchangers 2. Relative direction of motion of fluid Co-current (Parallel) flow (uni-direction flow) In a parallel flow heat exchanger, as the name suggests, the two fluid stream (hot and cold) travel in the same direction. The two stream enters at one end and leaves at the other end. T between the hot and cold fluids goes on decreasing from inlet to outlet

24 Parallel flow Heat Exchanger

25 Co-current (Parallel) flow Since this type of heat exchanger needs a large area of heat transfer, therefore, it is rarely used in practice. Examples: Oil coolers, oil heaters, water heaters As the two fluids are separated by a wall, this type of heat exchanger may be called parallel flow recuperator or surface heat exchanger

26 Classification of Heat Exchangers 2. Relative direction of motion of fluid Counter flow In counter flow heat exchanger, the two fluids flow in opposite directions. The hot and cold fluids enter at the opposite ends. T between the two fluids remains more or less nearly constant.

27 Counter flow Heat Exchanger

28 Counter flow This type of heat exchanger, due to counter flow, gives maximum rate of heat transfer for a given surface areas. Hence such heat exchangers are most favored for heating and cooling of fluids.

29 Different flow configurations in cross-flow heat exchangers. Classification of Heat Exchangers 2. Relative direction of motion of fluid Cross flow In cross flow heat exchangers, the two fluids (hot and cold) cross one another in space usually at right angles.

30 Cross flow Hot fluid flows in the separate tubes and there is no mixing of the fluid streams. The cold fluid is perfectly mixed as it flows through exchanger. The temperature of this mixed fluid will be uniform across any section and will vary only in the direction of flow. Examples: the cooling unit of refrigeration system

31 Classification of Heat Exchangers In this case each of the fluids follows a prescribed path and is unmixed as it flows through heat exchanger. Hence the temperature of the fluid leaving the heater section is not uniform. Examples: radiator Automobile

32 Cross flow In yet another arrangement, both the fluids are mixed while they travel through the exchanger; consequently the temperature of both the fluids is uniform across the section and varies only in the direction in which flow takes place.

33 Classification of Heat Exchangers 3. Design and constructional features (Mechanical design of heat exchange surface) Concentric tubes In this type, two concentric tubes are used, each carrying one of the fluids. The direction of flow may be parallel or counter The effectiveness of the heat exchanger is increased by using swirling flow.

34 Classification of Heat Exchangers 3. Design and constructional features (Mechanical design of heat exchange surface) Shell and tube In this type of heat exchanger one of the fluids flows through a bundle of tubes enclosed by a shell. The other fluid is forced through the shell and it flows over the outside surface of the tubes. Such an arrangement is employed where reliability and heat transfer effectiveness are important

35 Shell-and-tube heat exchanger: The most common type of heat exchanger in industrial applications. They contain a large number of tubes (sometimes several hundred) packed in a shell with their axes parallel to that of the shell. Heat transfer takes place as one fluid flows inside the tubes while the other fluid flows outside the tubes through the shell. Shell-and-tube heat exchangers are further classified according to the number of shell and tube passes involved. The schematic of a shell and tube heat exchanger (one shell pass and one tube pass) 35

36 Classification of Heat Exchangers 3. Design and constructional features (Mechanical design of heat exchange surface) Multiple shell and tube passes Multiple shell and tube passes are used for enhancing the overall heat transfer. Multiple shell pass is possible where the fluid flowing through the shell is re-routed. The shell side fluid is forced to flow back and forth across the tubes by baffles. Multiple tube pass exchangers are those which re-route the fluid through tubes in the opposite direction.

37 Multi pass flow arrangements in shell and tube heat exchangers

38 Classification of Heat Exchangers 3. Design and constructional features (Mechanical design of heat exchange surface) Compact heat exchangers There are special purpose heat exchangers and have a very large surface area per unit volume of the exchanger. They are generally employed when convective heat transfer coefficient associated with one of the fluids is much smaller than that associated with the other fluid. Example: Plate fin, flattened fin tube exchangers

39 Plate and frame (or just plate) heat exchanger: Consists of a series of plates with corrugated flat flow passages. The hot and cold fluids flow in alternate passages, and thus each cold fluid stream is surrounded by two hot fluid streams, resulting in very effective heat transfer. Well suited for liquid-to-liquid applications. A plate-and-frame liquid-to-liquid heat exchanger.

40 Classification of Heat Exchangers 4. Physical state of heat exchanging fluids (condensation and evaporation) Condenser In condenser, the condensing fluid remains at constant temperature throughout the exchanger while the temperature of the colder fluid gradually increases from inlet to outlet. The hot fluid loses latent part of heat which is accepted by the cold fluid.

41 Classification of Heat Exchangers 4. Physical state of heat exchanging fluids (condensation and evaporation) Evaporator In this case, the boiling fluid (cold fluid) remains at constant temperature while the temperature of hot fluid gradually decreases from inlet to outlet.

42 THE OVERALL HEAT TRANSFER COEFFICIENT A heat exchanger typically involves two flowing fluids separated by a solid wall. Heat is first transferred from the hot fluid to the wall by convection, through the wall by conduction, and from the wall to the cold fluid again by convection. Any radiation effects are usually included in the convection heat transfer coefficients. Thermal resistance network associated with heat transfer in a double-pipe heat exchanger. 42

43 U the overall heat transfer coefficient, W/m 2 C The two heat transfer surface areas associated with a double pipe heat exchanger (for thin tubes, Di Do and thus Ai Ao When The overall heat transfer coefficient U is dominated by the smaller convection coefficient. When one of the convection coefficients is much smaller than the other (say, h i << h o ), we have 1/h i >> 1/h o, and thus U h i. This situation arises frequently when one of the fluids is a gas and the other is a liquid. In such cases, fins are commonly used on the gas side to enhance the product UA and thus the heat transfer on that side. 43

44 The overall heat transfer coefficient ranges from about 10 W/m 2 C for gas-to-gas heat exchangers to about 10,000 W/m 2 C for heat exchangers that involve phase changes. When the tube is finned on one side to enhance heat transfer, the total heat transfer surface area on the finned side is For short fins of high thermal conductivity, we can use this total area in the convection resistance relation R conv = 1/hA s To account for fin efficiency 44

45 Fouling Factor The performance of heat exchangers usually deteriorates with time as a result of accumulation of deposits on heat transfer surfaces. The layer of deposits represents additional resistance to heat transfer. This is represented by a fouling factor R f. The fouling factor increases with the operating temperature and the length of service and decreases with the velocity of the fluids. Precipitation fouling of ash particles of superheater tubes 45

46 Points worth noting 1. The overall heat transfer coefficient depends upon the following factors: The flow rate The properties of the fluid The thickness of material The surface condition of the tubes and The geometric configuration of the heat exchanger

47 Points worth noting 2. The overall heat transfer coefficient U will generally decrease when any of the fluids (e.g. tars, oils or any of the gases) having low values of heat transfer coefficient, h flows on one side of the exchanger. 3. The highly conducting liquids such as water and liquid metals give much higher values of heat transfer coefficient, h and overall heat transfer coefficient, U. In case of boiling and condensation processes also, the value of U are high.

48 Points worth noting 4. All the thermal resistances in the heat exchanger must be low for its efficient and effective design.

49 Common failures in heat exchanger Choking of tubes either expected or extraordinary Excessive transfer rates in heat exchanger Increasing the pump pressure to maintain throughout Failure to clean tubes at regularly scheduled intervals Excessive temperatures in heat exchangers Lack of control of heat exchangers atmosphere to retard scaling Increased product temperature over a safe design limit. Unexpected radiation from refractory surfaces Unequal heating around the circumference or along the length of tubes

50 ANALYSIS OF HEAT EXCHANGERS An engineer often finds himself or herself in a position 1. to select a heat exchanger that will achieve a specified temperature change in a fluid stream of known mass flow rate - the log mean temperature difference (or LMTD) method. 2. to predict the outlet temperatures of the hot and cold fluid streams in a specified heat exchanger - the effectiveness NTU method. The rate of heat transfer in heat exchanger (HE is insulated): Two fluid streams that have the same capacity rates experience the same temperature change in a wellinsulated heat exchanger. heat capacity rate

51 is the rate of evaporation or condensation of the fluid h fg is the enthalpy of vaporization of the fluid at the specified temperature or pressure. The heat capacity rate of a fluid during a phase-change process must approach infinity since the temperature change is practically zero. T m an appropriate mean (average) temperature difference between the two fluids Variation of fluid temperatures in a heat exchanger when one of the fluids condenses or boils.

52 THE LOG MEAN TEMPERATURE DIFFERENCE METHOD log mean temperature difference Variation of the fluid temperatures in a parallel-flow double-pipe heat exchanger.

53 The arithmetic mean temperature difference The logarithmic mean temperature difference T lm is an exact representation of the average temperature difference between the hot and cold fluids. Note that T lm is always less than T am. Therefore, using T am in calculations instead of T lm will overestimate the rate of heat transfer in a heat exchanger between the two fluids. When T 1 differs from T 2 by no more than 40 percent, the error in using the arithmetic mean temperature difference is less than 1 percent. But the error increases to undesirable levels when T 1 differs from T 2 by greater amounts.

54 Counter-Flow Heat Exchangers In the limiting case, the cold fluid will be heated to the inlet temperature of the hot fluid. However, the outlet temperature of the cold fluid can never exceed the inlet temperature of the hot fluid. For specified inlet and outlet temperatures, T lm a counter-flow heat exchanger is always greater than that for a parallel-flow heat exchanger. That is, T lm, CF > T lm, PF, and thus a smaller surface area (and thus a smaller heat exchanger) is needed to achieve a specified heat transfer rate in a counterflow heat exchanger. When the heat capacity rates of the two fluids are equal

55 Multipass and Cross-Flow Heat Exchangers: Use of a Correction Factor F correction factor depends on the geometry of the heat exchanger and the inlet and outlet temperatures of the hot and cold fluid streams. F for common cross-flow and shell-andtube heat exchanger configurations is given in the figure versus two temperature ratios P and R defined as 1 and 2 inlet and outlet T and t shell- and tube-side temperatures F = 1 for a condenser or boiler 55

56 Correction factor F charts for common shelland-tube heat exchangers. 56

57 Correction factor F charts for common cross-flow heat exchangers. 57

58 The LMTD method is very suitable for determining the size of a heat exchanger to realize prescribed outlet temperatures when the mass flow rates and the inlet and outlet temperatures of the hot and cold fluids are specified. With the LMTD method, the task is to select a heat exchanger that will meet the prescribed heat transfer requirements. The procedure to be followed by the selection process is: 1. Select the type of heat exchanger suitable for the application. 2. Determine any unknown inlet or outlet temperature and the heat transfer rate using an energy balance. 3. Calculate the log mean temperature difference T lm and the correction factor F, if necessary. 4. Obtain (select or calculate) the value of the overall heat transfer coefficient U. 5. Calculate the heat transfer surface area A s. The task is completed by selecting a heat exchanger that has a heat transfer surface area equal to or larger than A s.

59 THE EFFECTIVENESS NTU METHOD A second kind of problem encountered in heat exchanger analysis is the determination of the heat transfer rate and the outlet temperatures of the hot and cold fluids for prescribed fluid mass flow rates and inlet temperatures when the type and size of the heat exchanger are specified. Heat transfer effectiveness the maximum possible heat transfer rate C min is the smaller of C h and C c

60 Actual heat transfer rate

61 The effectiveness of a heat exchanger depends on the geometry of the heat exchanger as well as the flow arrangement. Therefore, different types of heat exchangers have different effectiveness relations. We illustrate the development of the effectiveness e relation for the double-pipe parallel-flow heat exchanger.

62 Effectiveness relations of the heat exchangers typically involve the dimensionless group UA s /C min. This quantity is called the number of transfer units NTU. capacity ratio For specified values of U and C min, the value of NTU is a measure of the surface area A s. Thus, the larger the NTU, the larger the heat exchanger. The effectiveness of a heat exchanger is a function of the number of transfer units NTU and the capacity ratio c.

63

64 Effectiveness for heat exchangers.

65

66 When all the inlet and outlet temperatures are specified, the size of the heat exchanger can easily be determined using the LMTD method. Alternatively, it can be determined from the effectiveness NTU method by first evaluating the effectiveness from its definition and then the NTU from the appropriate NTU relation.

67 (e.g., boiler, condenser)

68 Observations from the effectiveness relations and charts The value of the effectiveness ranges from 0 to 1. It increases rapidly with NTU for small values (up to about NTU = 1.5) but rather slowly for larger values. Therefore, the use of a heat exchanger with a large NTU (usually larger than 3) and thus a large size cannot be justified economically, since a large increase in NTU in this case corresponds to a small increase in effectiveness. For a given NTU and capacity ratio c = C min /C max, the counter-flow heat exchanger has the highest effectiveness, followed closely by the cross-flow heat exchangers with both fluids unmixed. The lowest effectiveness values are encountered in parallel-flow heat exchangers. The effectiveness of a heat exchanger is independent of the capacity ratio c for NTU values of less than about 0.3. The value of the capacity ratio c ranges between 0 and 1. For a given NTU, the effectiveness becomes a maximum for c = 0 (e.g., boiler, condenser) and a minimum for c = 1 (when the heat capacity rates of the two fluids are equal).

69 SELECTION OF HEAT EXCHANGERS The uncertainty in the predicted value of U can exceed 30 percent. Thus, it is natural to tend to overdesign the heat exchangers. Heat transfer enhancement in heat exchangers is usually accompanied by increased pressure drop, and thus higher pumping power. Therefore, any gain from the enhancement in heat transfer should be weighed against the cost of the accompanying pressure drop. Usually, the more viscous fluid is more suitable for the shell side (larger passage area and thus lower pressure drop) and the fluid with the higher pressure for the tube side. The proper selection of a heat exchanger depends on several factors: Heat Transfer Rate Cost Pumping Power Size and Weight Type Materials The rate of heat transfer in the prospective heat exchanger The annual cost of electricity associated with the operation of the pumps and fans

70 Summary Types of Heat Exchangers The Overall Heat Transfer Coefficient Fouling factor Analysis of Heat Exchangers The Log Mean Temperature Difference Method Counter-Flow Heat Exchangers Multipass and Cross-Flow Heat Exchangers: Use of a Correction Factor The Effectiveness NTU Method Selection of Heat Exchangers

Chapter 11 HEAT EXCHANGERS

Chapter 11 HEAT EXCHANGERS Heat Transfer Chapter 11 HEAT EXCHANGERS Universitry of Technology Materials Engineering Department MaE216: Heat Transfer and Fluid bjectives Recognize numerous types of heat exchangers, and classify them

More information

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations.

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations. HEAT EXCHANGERS INTRODUCTION The devices that are used to facilitate heat transfer between two or more fluids at different temperatures are known as heat exchangers. Different types and sizes of heat exchangers

More information

CL4001 HEAT TRANSFER OPERATIONS

CL4001 HEAT TRANSFER OPERATIONS CL4001 HEAT TRANSFER OPERATIONS MODULE V Lecture Notes: Debasree Ghosh HEAT EXCHANGER Lecturer, Department of Chemical Engineering, Birla Institute of Technology, Mesra Heat Exchangers: Introduction and

More information

THE GATE COACH All Rights Reserved 28, Jia Sarai N.Delhi-16, ,-9998

THE GATE COACH All Rights Reserved 28, Jia Sarai N.Delhi-16, ,-9998 1 P a g e 1 BASIC CONCEPTS IN HEAT TRANSFER Introduction 3 Thermodynamics vs Heat transfer 4 Essential conditions for heat transfer 4 Heat transfer mechanism 4 Thermal conductivity 7 2 CONDUCTION Steady

More information

How is the heat transfer?

How is the heat transfer? How is the heat transfer? As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists until thermal equilibrium is

More information

As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists

As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists until thermal equilibrium is reached. Heat transfer by:

More information

Heat exchangers are devices that facilitate the exchange of heat between

Heat exchangers are devices that facilitate the exchange of heat between cen58933_ch3.qxd 9/9/2002 9:57 AM Page 667 HEAT EXCHANGERS CHAPTER 3 Heat exchangers are devices that facilitate the exchange of heat between two fluids that are at different temperatures while keeping

More information

Introduction to Heat Exchangers

Introduction to Heat Exchangers HEAT EXCHANGERS Introduction to Heat Exchangers What Are Heat Exchangers? Heat exchangers are units designed to transfer heat from a hot flowing stream to a cold flowing stream. Why Use Heat Exchangers?

More information

Mechanical Engineering Department Sheet (1)

Mechanical Engineering Department Sheet (1) Benha University Heat and Mass Transfer Faculty of Engineering at Shoubra 3 rd Year (Power) Mechanical Engineering Department Sheet (1) (1) What is heat exchanger? Mention with brief description and sketches

More information

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ] Experiment 1 Study of fundamentals of Fluid Flow and Heat Transfer associated with Heat Exchangers Review questions (1) Significance of dimensionless numbers. (2) Define overall heat transfer coefficient.

More information

Heat Exchangers. Heat Exchangers 1

Heat Exchangers. Heat Exchangers 1 Heat Exchangers Heat Exchangers 1 How is the heat transfer? Mechanism of Convection Applications. Mean fluid Velocity and Boundary and their effect on the rate of heat transfer. Fundamental equation of

More information

In the name of God. Jami Institute of Jami - Mehdi Rasti

In the name of God. Jami Institute of Jami - Mehdi Rasti In the name of God 1 Heat Transfer Jami Institute of Technology Heat Exchangers part 2 Mehdi Rasti 2 The Counter-Flow Heat Exchanger In contrast to the parallel-flow exchanger, this configuration provides

More information

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium. Convection 1 Physical Mechanism of Convection Conduction and convection are similar in that both mechanisms require the presence of a material medium. But they are different in that convection requires

More information

MECHANICAL SCIENCE Module 2 Heat Exchangers

MECHANICAL SCIENCE Module 2 Heat Exchangers Department of Energy Fundamentals Handbook MECHANICAL SCIENCE Module 2 Heat Exchangers Heat Exchangers DOE-HDBK-1018/1-93 TABLE OF CONTENTS TABLE OF CONTENTS LIST OF FIGURES... ii LIST OF TABLES... iii

More information

The Condensate Water Systems

The Condensate Water Systems The Condensate Water Systems Condenser: A closed vessel in which steam is condensed by abstracting the heat and where the pressure is maintained below atmospheric pressure is known as a condenser. The

More information

By: Prof K. M. Joshi,

By: Prof K. M. Joshi, Condensers The condenser is a two-phase flow heat exchanger (HEX) where the heat (generally latent heat) is removed by conversion of vapor into liquid with the help of coolant. By: Prof K. M. Joshi, Assi.

More information

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT Mazhar Mumbaiwala 1, Rahul Panjwani 2, Rishikesh Shulav 3, Shashwat Budholia 4, Anshu Kumar 5 1,2,3,4UG

More information

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way 1 CHAPTER I INTRODUCTION In the modern life, electronic equipments have made their way in to practically every part, which is from electronic gadgets to high power computers. Electronic components have

More information

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University 2 Objectives Differentiate between dry air and atmospheric air. Define and calculate

More information

Air-Cooling Evaporators

Air-Cooling Evaporators Air-Cooling Evaporators Types of construction Circuit Configurations Methods of Refrigerant Feed Methods of Air Circulation Methods of Defrost Type of Construction Bare tube Finned Tube Plate-surface Bare

More information

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING Sample Questions and Answers CHAPTER 5 EVAPORATORS 1. What is Evaporator? Classify the various types of evaporator. Evaporator

More information

Evaporation System: Types and Design Aspects

Evaporation System: Types and Design Aspects Evaporation System: Types and Design Aspects Dr. Pankaj Kumar, Er. Dhritiman Saha and Er. Chandan Solanki Food Grains and Oil Seeds Processing Division, ICAR-CIPHET, Ludhiana Evaporation is an important

More information

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

Experiment 2: Test on Domestic Refrigerator for evaluation of EER. Experiment 2: Test on Domestic Refrigerator for evaluation of EER. Specifications of Domestic Refrigerator: Model: Videocon refrigerator (single door) Capacity: 150 lit. Compressor: Hermetically Sealed

More information

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN Air Conditioning Clinic Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN Absorption Water Chillers One of the Equipment Series A publication of The Trane Company Worldwide Applied Systems

More information

Heat Recovery Units. Heat Recovery 1

Heat Recovery Units. Heat Recovery 1 Heat Recovery Units Heat Recovery 1 Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air

More information

Boiler. Fire tube Boiler:

Boiler. Fire tube Boiler: Boiler What is Boiler? A closed metallic vessel in which the water is heated beyond the boiling temperature by the application of heat by the combustion of fuels to convert it into steam. The function

More information

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 1. OBJECTIVE The objective of this experiment is to observe four basic psychrometric processes

More information

2. HEAT EXCHANGERS MESA

2. HEAT EXCHANGERS MESA 1. INTRODUCTION Multiport minichannel and microchannel aluminium tubes are becoming more popular as components in heat exchangers. These heat exchangers are used in various industrial applications and

More information

Solution of I Mid Term Steam Engineering 6ME5A

Solution of I Mid Term Steam Engineering 6ME5A 1(a) Discuss the working principle of LaMont high pressure boiler This boiler works on basic principle of forced convection. If the water is circulate by a pump inside the tube, the heat transfer rate

More information

CFD ANALYSIS OF DOUBLE PIPE PARALLEL FLOW HEAT EXCHANGER

CFD ANALYSIS OF DOUBLE PIPE PARALLEL FLOW HEAT EXCHANGER CFD ANALYSIS OF DOUBLE PIPE PARALLEL FLOW HEAT EXCHANGER 1 DIVI VENKATA PRASHANTH, 2 GOROGINAM SANTHI 1 Pg Scholar, Department of MECH, BRILLIANT GRAMMER SCHOOL EDUCATIONAL SOCIETY S (BRIG),JNTUH,Hyderabad.Abdullapurmet

More information

Steam Generator (Boiler) & Steam Turbine. Steam Generator (Boiler) ME 268. Model Lab

Steam Generator (Boiler) & Steam Turbine. Steam Generator (Boiler) ME 268. Model Lab Steam Generator (Boiler) ME 268 Model Lab Aashique Alam Rezwan Lecturer Department of Mechanical Engineering, BUET, Dhaka-1000 http://teacher.buet.ac.bd/aashiquear ME 268 Aashique Alam Rezwan 1 Modern

More information

Heat Exchangers. Seminar report. Submitted in partial fulfillment of the requirement for the award of degree Of Mechanical

Heat Exchangers. Seminar report.  Submitted in partial fulfillment of the requirement for the award of degree Of Mechanical A Seminar report on Heat Exchangers Submitted in partial fulfillment of the requirement for the award of degree Of Mechanical SUBMITTED TO: SUBMITTED BY: www.studymafia.org www.studymafia.org Preface I

More information

Appendix A. Glossary of Common Terms

Appendix A. Glossary of Common Terms Glossary of Common Terms Glossary of Common Terms Absorption chiller A refrigeration machine using heat as the power input to generate chilled water. Adjustable speed drive A means of changing the speed

More information

Waste-heat recovery: Weighing in the environmental Factor

Waste-heat recovery: Weighing in the environmental Factor Waste-heat recovery: Weighing in the environmental Factor Engineer's Digest Magazine August 1989 Richard P. Zoldak, P.E. Market Development Manager Alfa-Laval Thermal Co. Thermal pollution and process-waste

More information

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points Name: Start time: End time: FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points 1. What are the units of the following quantities? (10 points) a. Enthalpy of a refrigerant b. Dryness fraction of

More information

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY MASS & E ERGY BALA CES I PSYCHROMETRIC PROCESSES EXPERIME T 3 1. OBJECTIVE The object of this experiment is to observe four basic psychrometric processes

More information

The theory behind heat transfer

The theory behind heat transfer Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineered solutions. Our equipment, systems and services are dedicated to helping customers to optimize the performance

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.

More information

THERMAL ENGINEERING & GAS DYNAMICS ME-6002

THERMAL ENGINEERING & GAS DYNAMICS ME-6002 SAGAR INSTITUTE OF RESEARCH & TECHNOLOGY, BHOPAL DEPARTMENT OF MECHANICAL ENGINEERING THERMAL ENGINEERING & GAS DYNAMICS ME-6002 1 UNIT I STEAM GENERATOR SYLLABUS Steam generators: classification, conventional

More information

Contents. Preface... xvii

Contents. Preface... xvii Contents Preface... xvii Chapter 1. Rotary Calcination Kiln: Heat Exchange by Radiation... 1 1.1. General points.................................. 1 1.1.1. Purpose of calcination kilns........................

More information

(Refer Slide Time: 00:00:40 min)

(Refer Slide Time: 00:00:40 min) Refrigeration and Air Conditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Lecture No. # 10 Vapour Compression Refrigeration Systems (Refer Slide

More information

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance #1 Jaydev S. Bade, #2 Dr. Nitin U. Korde 1 Department of Mechanical Engineering, Savitribai Phule

More information

Efficient Steam System Design

Efficient Steam System Design Efficient Steam System Design The word Efficient is often used to describe the general performance of a system. However it is important to distinguish between efficiency and effectiveness. Efficiency is

More information

Compression of Fins pipe and simple Heat pipe Using CFD

Compression of Fins pipe and simple Heat pipe Using CFD Compression of Fins pipe and simple Heat pipe Using CFD 1. Prof.Bhoodev Mudgal 2. Prof. Gaurav Bhadoriya (e-mail-devmudgal.mudgal@gmail.com) ABSTRACT The aim of this paper is to identify the advantages

More information

Heat pump and energy recovery systems

Heat pump and energy recovery systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air

More information

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb. HVAC Math The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb. Math F. to C. Conversion = (f-32)*(5/9) C. to F. Conversion = C * 9/5 +

More information

Brown Hills College of Engineering & Technology

Brown Hills College of Engineering & Technology UNIT 6 Steam Condensers Elements of a condensing plant, Types of condensers, Comparison of jet and surface condensers, Condenser vacuum, Sources of air leakage & its disadvantages, Vacuum efficiency, Condenser

More information

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

AIR CONDITIONING. Carrier Corporation 2002 Cat. No AIR CONDITIONING Carrier Corporation 2002 Cat. No. 020-016 1. This refresher course covers topics contained in the AIR CONDITIONING specialty section of the North American Technician Excellence (NATE)

More information

Boiler Draft Equipment

Boiler Draft Equipment Boiler Draft Equipment Learning Outcome When you complete this module you will be able to: Discuss, sketch and describe the basic equipment used to supply combustion air to a boiler furnace. Learning Objectives

More information

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS 168 CHAPTER 7 COMPARISON OF HEAT EXCHANGERS Heat exchangers may be classified according to their flow arrangement. In parallel flow heat exchangers, the two fluids enter the exchanger at the same end,

More information

Unit THE NATURE OF HEAT

Unit THE NATURE OF HEAT Unit 5.0 - THE NATURE OF HEAT Heat is a form of energy, in the form of infrared radiation. Heat from the sun travels through space at the speed of 300,000,000 m/s. Upon arriving on earth, much of the radiant

More information

Boiler Basics. Design and operation

Boiler Basics. Design and operation Boiler Basics Design and operation A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam. The hot water or steam under

More information

No matter how adventurous a process engineer may

No matter how adventurous a process engineer may No matter how adventurous a process engineer may be in private, if it really matters to his or her work, conservatism tends to be the order of the day. This is perfectly understandable. When the result

More information

MODULE 6 HUMIDIFICATION AND AIR CONDITIONING

MODULE 6 HUMIDIFICATION AND AIR CONDITIONING MODULE 6 HUMIDIFICATION AND AIR CONDITIONING LECTURE NO. 3 6.3 Humidification and dehumidification operations and design calculations Humidification operations: In this operation, water transfers from

More information

Chapter 2.3: Steam System

Chapter 2.3: Steam System Part I: Objective type Questions and Answers Chapter 2.3: Steam System 1. For industrial process heating, the best quality of steam is: a) dry saturated steam b) superheated steam c) wet steam d) high

More information

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering) Set No. 1 IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec - 2014 REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering) Time: 3 hours Max. Marks: 75 Answer any FIVE Questions All Questions

More information

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis Technical Development Program Technical Development Programs (TDP) are modules of technical training on HVAC theory, system

More information

2. CURRICULUM. Sl. No.

2. CURRICULUM. Sl. No. . CURRICULUM Sl. No. Code Title No. of Lecture Hours 1 RAC 001 Fundamentals of Refrigeration and Air 60 conditioning RAC 00 Psychrometry, Heat load Estimation for 70 Air conditioning and Refrigeration

More information

Modern Heat Exchanger - A Review

Modern Heat Exchanger - A Review Modern Heat Exchanger - A Review Mr. Irfan Aiyubbhai Vohra 1, Prof. Azim Aijaj 2, Dr. B.B. Saxena 3 1 M.Tech Student, P.C.S.T. Bhopal,M.P. 2 Assosiate Professor, P.C.S.T. Bhopal,M.P. 3 H.O.D.Mechanical

More information

PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS

PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS M.Srinivasa Rao M.Tech Student, Department of Mechanical Engineering, GMRIT, Srikakulam, AP, India.

More information

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction: Refrigeration Systems Theoretical hours: 2 Practical hours: 2 Units: 6 COOLING TOWERS First 10 minutes: review the last lecture. Then explain the new lecture, solve an example. Last 10 minutes review the

More information

Paper No. : 04 Paper Title: Unit Operations in Food Processing Module- 14:Evaporation

Paper No. : 04 Paper Title: Unit Operations in Food Processing Module- 14:Evaporation Paper No. : 04 Paper Title: Unit Operations in Food Processing Module- 14:Evaporation 14.1 Introduction Evaporation is a common unit operation in food processing industries in which partial removal of

More information

PESIT-Bangalore South Campus

PESIT-Bangalore South Campus USN PESIT Bangalore South Campus Hosur road, 1km before Electronic City, Bengaluru -560-100 Department of Mechanical Engineering INTERNAL ASSESSMENT TEST 2 Date : 03/04/2018 Max Marks : 50 Subject & Code

More information

COOPERATIVE PATENT CLASSIFICATION

COOPERATIVE PATENT CLASSIFICATION CPC F COOPERATIVE PATENT CLASSIFICATION MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING (NOTE omitted) LIGHTING; HEATING F28 HEAT EXCHANGE IN GENERAL (NOTES omitted) F28D HEAT-EXCHANGE APPARATUS,

More information

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING Thermodynamics: An Engineering Approach, 6 th Edition Yunus A. Cengel, Michael A. Boles McGraw-Hill, 2008 Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING Mehmet Kanoglu Copyright The McGraw-Hill Companies,

More information

Review on Waste Heat Recovery Techniques in Air Conditioning Application

Review on Waste Heat Recovery Techniques in Air Conditioning Application International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2016 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Review Article Review

More information

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) AN EXPERIMENTAL STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) AN EXPERIMENTAL STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 6340(Print), ISSN 0976 6340 (Print) ISSN 0976 6359

More information

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers Ashraf A 1, Mohammed Shan N 2, Thoufeeq Azad 3, Bibin S4, Arun S 5 1-4 Students, 5 Assistant Professor Department of

More information

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful Harnessing Energy Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful Vapor Power Cycle The vast majority of electrical generating plants are variations of vapor power

More information

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers Chapter 4 Performance Evaluation Criteria for Two-Phase Heat Exchangers Prof. Min Zeng 1/50 1. Introduction 2. Operating Characteristics of Two-phase Heat Exchangers 3. Enhancement in Two-Phase Heat Exchange

More information

TMCI Padovan Evaporators

TMCI Padovan Evaporators TMCI Padovan Evaporators Evaporators Our range includes 4 types of evaporators: Forced Circulation Falling Film Evaporators Plates Thin Film Concentration systems Evaporator choosing criteria: product

More information

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK St.MARTIN S ENGINEERING COLLEGE Dhulapally, Secunderabad-500 014 Subject: REFRIGERATION AND AIR CONDITIONING Class : ECE III 1 Define Unit of refrigeration. 2 Define C.O.P. QUESTION BANK 3 What is the

More information

WHAT IS A BOILER? BOILER IS AN EQUIPMENT WHICH PRODUCES STEAM AT THE REQUIRED PRESSURE AND TEMPERATURE. BOILER DESIGN, MANUFACTURE & INSTALLATION ARE

WHAT IS A BOILER? BOILER IS AN EQUIPMENT WHICH PRODUCES STEAM AT THE REQUIRED PRESSURE AND TEMPERATURE. BOILER DESIGN, MANUFACTURE & INSTALLATION ARE Your Logo Here TRAINING ON BOILERS PRESENTED AT M/S. MAGADI SODA COMPANY, MAGADI, KENYA LIMITED 1 WHAT IS A BOILER? BOILER IS AN EQUIPMENT WHICH PRODUCES STEAM AT THE REQUIRED PRESSURE AND TEMPERATURE.

More information

Sustainable Techniques in Refrigerated Space

Sustainable Techniques in Refrigerated Space Sustainable Techniques in Refrigerated Space Sustainability and high performance of refrigerated space used for the preservation of perishable product capitalizes on conservation techniques which reduce

More information

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202 Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202 Applied Thermodynamics Sessional Credit Hours: 0.75 General Guidelines:

More information

HVAC Fundamentals & Refrigeration Cycle

HVAC Fundamentals & Refrigeration Cycle HVAC Fundamentals & Refrigeration Cycle Change of State of Water & the Refrigeration Cycle Change of State Water The Basic Refrigeration Cycle Types of DX Systems The Chilled water System The Cooling Tower

More information

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium. Convection 1 Physical Mechanism of Convection Conduction and convection are similar in that both mechanisms require the presence of a material medium. But they are different in that convection requires

More information

Chapter 10. Passive Cooling Contents

Chapter 10. Passive Cooling Contents Chapter 10. Passive Cooling Contents 10.1 Introduction to Cooling 10.2 Historical and Indigenous Use of Passive Cooling 10.3 Passive Cooling Systems 10.4 Comfort Ventilation VS Night Flush Cooling 10.5

More information

TECHNICAL CATALOGUE Section 1 Technical Information

TECHNICAL CATALOGUE Section 1 Technical Information TECHNICAL CATALOGUE Section 1 Technical Information North America 1.800.335.6650 - International 1.902.659.2424 - Fax: 1.902.659.2800 - http://www.heatexchangers.ca 1 Table of Contents TABLE OF CONTENTS...2

More information

ENSC 388: Engineering Thermodynamics and Heat Transfer

ENSC 388: Engineering Thermodynamics and Heat Transfer ENSC 388: Engineering Thermodynamics and Heat Transfer Experiment 3: Free and Forced Convection Objective Determination of heat transfer coefficient for free and forced convection for different geometries.

More information

Experiment 12 Shell and Tube Heat Exchanger. Aim of this Experiment

Experiment 12 Shell and Tube Heat Exchanger. Aim of this Experiment Experiment 12 Shell and Tube Heat Exchanger Aim of this Experiment The shell and tube exchanger is a simple model that demonstrates the basic principles of heat transfer consists of a number of tubes in

More information

B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F)

B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F) B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F) Q. 1. (a) Differentiate between water tube boiler and fire tube boiler. Ans. Comparison Between 'Fire-tube and Water tube'

More information

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant Proceedings of the World Congress on Momentum, Heat and Mass Transfer (MHMT 16) Prague, Czech Republic April 4 5, 216 Paper No. ENFHT 111 DOI: 1.11159/enfht16.111 Experimental Investigation of a Multi

More information

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2 Modern Applied Science; Vol. 9, No. 13; 2015 ISSN 1913-1844 E-ISSN 1913-1852 Published by Canadian Center of Science and Education The Design of a Shell-Tube Heat Exchanger as Evaporator an Absorption

More information

HEAT PIPES

HEAT PIPES HEAT PIPES * Shaikh Naushad, Design Engineer PTC, Communication Concept, Saudi Arabia INTRODUCTION A heat pipe is a device that efficiently transports thermal energy from its one point to the other. It

More information

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel. MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) Q 1. a) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel. 2) steam turbine- It is a device that extract

More information

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this lecture are to: 1. Importance of complete vapour compression refrigeration

More information

Enhancement of Heat Exchanger Performance by the Extended Surfaces-Fins

Enhancement of Heat Exchanger Performance by the Extended Surfaces-Fins Enhancement of Heat Exchanger Performance by the Extended Surfaces-Fins Piyush Kumar Kashyap 1, priyanka jhavar 2 1 sri satya sai, College of engineering& science, Sheore, 466001 Abstract: 2 sri satya

More information

Technical Development Program

Technical Development Program Technical Development Program COMMERCIAL HVAC CHILLER EQUIPMENT Water-Cooled Chillers PRESENTED BY: Omar Rojas Sales Engineer Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

More information

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS 9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS 9.1 Introduction Air conditioning and refrigeration consume significant amount of energy in buildings and in process industries. The energy consumed in

More information

Java Development Program on Parallel and Counter Flow Heat Exchanger

Java Development Program on Parallel and Counter Flow Heat Exchanger Java Development Program on Parallel and Counter Flow Heat Exchanger Mr. Tanmay Sahuji 1 Dept of Mechanical Engineering Walchand Institute of Technology (WIT), Solapur, India. Mr. Pritish Chitte 3 Assistant

More information

Steam and Gas Power Systems Prof Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee

Steam and Gas Power Systems Prof Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee Steam and Gas Power Systems Prof Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee Module No # 02 Lecture No # 09 Boilers Mountings and Accessories

More information

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments 1 P age Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments 2 P age Keywords: Pipe still heater, heat exchangers, distillation tower, pumps Refinery equipments Introduction In refinery,

More information

Drying rate 1. Section B to C of the curve, known as the constant rate periods, represents removal of unbound water from the product.

Drying rate 1. Section B to C of the curve, known as the constant rate periods, represents removal of unbound water from the product. Drying rate 1 Drying process of a material can be described as a series of steps in which drying rate plays a key role. Following figure shows typical drying rate curve for a constant drying conditions.

More information

Evaporators. Direct Expansion Flooded Recirculated Over Feed

Evaporators. Direct Expansion Flooded Recirculated Over Feed Evaporators Purpose: Liquid Refrigerant is Boiled from a Low Pressure Liquid to a Low Pressure Gas by Absorbing Heat from the Medium that is being Cooled Types: Direct Expansion Flooded Recirculated Over

More information

HEAT EXCHANGE IN GENERAL

HEAT EXCHANGE IN GENERAL XXXX F28 HEAT EXCHANGE IN GENERAL Note(s) (1) In this class, the following expressions are used with the meanings indicated: heat exchange means the heating or cooling of a fluid or fluent solid by direct

More information

Design Based Comparative Study of Several Condensers Komal B. Dabhi 1, Prof. S. B. Thakore 2 1 Chemical Engg. Dept., L. D. College of Engineering, Ahmedabad 380015 2 Chemical Engg. Dept., L. D. College

More information

CHAPTER 4. HVAC DELIVERY SYSTEMS

CHAPTER 4. HVAC DELIVERY SYSTEMS CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer

More information

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering Chapter 11 REFRIGERATION CYCLES Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University it Objectives Introduce the concepts of refrigerators and heat pumps and the measure of their performance.

More information

Adelaide Homes Design Guide 4 - Winter warming

Adelaide Homes Design Guide 4 - Winter warming Adelaide Homes Design Guide 4 - Winter warming Adelaide's temperate climate means home warming is required during winter. There are many efficient heating systems. The most economical method, however,

More information