Mitigating Risk of Battery Testing in Environmental Chambers. Mark Chrusciel & Wayne Diener Cincinnati Sub-Zero

Size: px
Start display at page:

Download "Mitigating Risk of Battery Testing in Environmental Chambers. Mark Chrusciel & Wayne Diener Cincinnati Sub-Zero"

Transcription

1 Mitigating Risk of Battery Testing in Environmental Chambers Mark Chrusciel & Wayne Diener Cincinnati Sub-Zero

2 First You Must Select the Right Environmental Chamber for Your Application The first steps are yours Type of Application What are you trying to do? Document your Requirements Write a Specification or reference your specification (sections that apply) Communicate with Supplier Designate a Primary Contact

3 What do You Need to Know (Defining the Application) What is being tested? Materials of construction, weight and configuration of DUT Are there fixtures involved? Is it powered, how much and when? Is the material hazardous? Is the requirement long or short term? Can impact solution and cost Do you want minimum or maximum transition rates EIC 61646

4 What do You Need to Know (Defining the Application) What is the temperature range? -34ºC to -40ºC is the practical limit of single stage -40ºC to -54ºC is the practical limit of two-stage or Tundra -73 o C for cascade Or LN 2 for lower temperatures What is your high temperature requirement? What is required ramp rate? Speed is money; how fast do you want to go? Air temp or part temp Linear rate or average rate Be sure to specify not only the minimum highs and lows, but also what range your test will be in

5 What do You Need to Know (Defining the Application) Are there air flow requirements? Part temperature requires high velocity air flow Does part configuration dictate air flow requirement? Will a standard chamber work? Is temperature uniformity a requirement? Live load? On during transitions?

6 What do You Need to Know (Defining the Application) Is humidity required? Standard range is 10-98% Low end limited by 5-7ºC dew point High end by 85ºC dry bulb Extended ranges is 5-98% Frozen coil and dry air purge required High end by 95ºC dry bulb Special requirements Maintained RH during transitions Live loads and RH

7 What do You Need to Know (Defining the Application) Any special requirements? Explosion Proof Local and State Codes Facility or Corporate standards MIL-STD s, IEC or UL specifications Sound power levels Regulatory agencies Test and Acceptance? Testing with customer product Customer witnessed testing Most vendors welcome this

8 What do You Need to Know (Defining the Application) What utilities are required? Power Water Air LN 2 What utilities are available? Are there move-in restrictions? Do you want installation/start-up/training?

9 Critical Equipment Decisions Chamber Types Cooling Options Humidification Options Air Flow Controllers

10 Chamber types Based on your application what works best? Conventional temperature or temp & RH chamber Air to air thermal shock Modular walk-in or welded walk-in Liquid thermal shock Stress screening or HALT & HASS Altitude simulation with & w/o temp. and/or RH Liquid conditioners Storage many types Custom Clean sheet of paper

11 Cooling Options Expendable Refrigerant Liquids/gases that can be injected directly into the space being cooled Two most popular refrigerants are: Liquid Nitrogen (LN2)» Cryogenic temperatures down to -184 o C Liquid Carbon Dioxide (CO2)» Temperature down to -68 o C Mechanically Cooled Use a compressor and circulate a refrigerant around a closed-loop system The ultimate low temperature required by your testing determines the type of refrigeration system needed.

12 Mechanical Refrigeration Options Single Stage: -34 o C Traditional single stage refrigeration system is rated to -40 o C However, due to the refrigerant used there is very little cooling capacity at -40 o C Tundra and Two-Stage Systems: -40 o C to -54 o C Cascade: -73 o C Two separate systems working to cool the chamber down

13 Refrigeration Decisions Compressors: Semi-Hermetic (7-1/2 to 30 hp) Hermetic (1 to 3 hp) Scroll ( 2 to 15 hp) Tandem Configurations Integral Water-or-air cooled condenser Options: Remote Power Pack Remote air-cooled condenser

14 Methods of Humidity Generation Boiler - Good generator, should not be used with live loads Atomizer - Good control, especially with live loads, but must be very clean Water Pan - Very stable, but slow response

15

16 Air Flow The airflow must have enough volume to support the refrigeration system. Typical air velocity in most reach-in chambers is approximately 100 ft/min through the work space This velocity works well for steady-state and temperature-cycling testing Air velocity across the part should be much higher to keep it closer to the chamber air temperature during transitions 500 ft/min or more is required It is a necessity in thermal shock applications to have airflow this high

17 Current Technology Touch Screen Controllers Ethernet Control & Monitoring Controller Types Automated Alarm Notifications via or text message. Automated back-up of data files Program the profile in one chamber and import to the others to saving valuable profile entry time. Integrated sends data files directly to an address from the controller with a touch of a button. Data logging - Easily download profiles, alarm files, audit trail files and data files to a removable USB stick. Full system security allows up to 30 users with three levels of security. X-Y Graphs (Real Time & Historical) Autostart Product Control

18 CAUTION More Bang for the Buck Generic choices aren t always the best choices If It s too good to be true, it probably is too good to be true The lowest price isn t always the best choice. You get what you pay for Where did the corners get cut? Compare Apples to Apples Are you getting the same thing? Used Chambers Can be a great deal but one service call can negate savings.

19 Batteries - What do we Need to Know?

20 What is the chemistry and the hazards? What specification do they have to run? Heat load? How is it done now? What is the failure mode?

21 Different Chemistries Lead Acid NiCD NiMh Li ion Hydro and Oxy Hydro and Oxy Hydro and Oxy Carbonates

22 Safety In each individual case the risk must be determined by the customer This information will allow us to determine what safety equipment must be installed. There is no standard safety equipment, as the risks may vary considerably.

23 Lithium Ion Gases not as much an issue as thermal runaway Self sustaining Short period of intense heat and pressure

24 Typical Failure Modes of Li-ion Batteries Cracks in membrane separating anode and cathode. Could also be a short caused by defect in production Over heating Over charging Under charging

25

26 Typical Tests Charge and discharge at high and low temperatures Temperature Cycling Altitude Humidity Vibration Batteries then tested to see if they lost charge or efficiencies

27 Cell Testing GM Corporation

28 Published Specifications UL 1642 General Safety testing of Li-ion batteries. IEC Safety standards for secondary Li-ion batteries. SAE J2464 General guidelines for rechargeable energy storage. UN/DOT 38.3 Standards for shipping lithium batteries.

29 Published Specifications IEC Safety of primary cells during shipment. UL 2580 Batteries for use in Electric Vehicles. IEC Reliability and abuse testing of secondary cells. IEC Testing of secondary cells.

30 Pack Testing GM Corporation

31 IEC Section Vibration Temperature cycling 30 minute ramps. Also High ambient and high temperature tests.

32 62133

33

34 Safety In each individual case the risk must be determined by the customer This information will allow us to determine what safety equipment must be installed. There is no standard safety equipment, as the risks may vary considerably.

35 Safety Options Temperature limited sheath heaters Standard ni-chrome wire heaters can reach temperatures of 540C. Temperature is set below auto ignition temp. of gases Non sparking fan blades or blower wheels Aluminum construction Intrinsically safe barriers preventing the potential of high voltage pulses. Fire suppression Inert Atmosphere Use of N2 or CO2 to eliminate Oxygen does not prevent thermal runaway but can help contain Liquid cooling Used to cool cells or packs if they overheat-may help prevent thermal runaway.

36 Safety Options Reinforced chamber floor To support weight and extreme temperatures Oversized pressure relief vent Protects chamber from a sudden release of high pressure gas. Rapid air exchange system Aids in removing all gases from inside the chamber prior to opening the door can be vented to the outside Gas monitors O2, H2, CO etc Can be interlocked to controller to shut down chambers-may need to be conditioned prior to sensing Safety door interlock Prevents entry either during tests or after an event Protective enclosure/structure for tests to failure. External structure that would contain any fire or explosion.

37 Conclusion Understand your products and it s failure modes and consequences. Communicate to your equipment/chamber suppliers and they will work with you to design a safe system.

38 Questions

39 Thank You Mark Chrusciel Cincinnati Sub-Zero

environmental chambers for Battery testing

environmental chambers for Battery testing environmental chambers for Battery testing www.cszproducts.com Battery Testing SOlutions We are a leading provider of environmental test chambers with over 78 years of industry experience in designing

More information

environmental chambers for Battery testing

environmental chambers for Battery testing environmental chambers for Battery testing www.cszindustrial.com Battery Testing SOlutions Cincinnati Sub-Zero (CSZ) is a leading provider of environmental test chambers with over 76 years of industry

More information

Selecting an Environmental Test Chamber

Selecting an Environmental Test Chamber Selecting an Environmental Test Chamber Eric Berchtold, Cincinnati Sub-Zero Cincinnati Sub-Zero Products, LLC 12011 Mosteller Road Cincinnati, Ohio 45241 513-772-8810 www.cszindustrial.com 1 Selecting

More information

Environmental.

Environmental. Environmental Walk-In / DRIVE-IN Chambers www.cszindustrial.com Environmental Walk-In Chambers Walk-In chambers are used for testing or storing products that require a large capacity chamber. Applications

More information

Z-Plus. Temperature/Humidity Chambers.

Z-Plus. Temperature/Humidity Chambers. Z-Plus Temperature/Humidity Chambers www.cszindustrial.com Z-Plus Series Temperature/Humidity Chambers Performance You Specify Reliability You Expect Features You Want Value You Need Energy You Save Z-Plus

More information

Z-Plus Series Temperature/Humidity

Z-Plus Series Temperature/Humidity Z-Plus Series Temperature/Humidity Performance You Specify Reliability You Expect Features You Want Value You Need Z-Plus chambers are used to test and store products by subjecting them to various temperature

More information

Remote Conditioners. RC-Series. ZPRC Series

Remote Conditioners.   RC-Series. ZPRC Series RC-Series Remote Conditioners RC Series ZPRC Series www.cszproducts.com Remote Conditioners Two chambers for the price of one Our dual-purpose RC-Series Remote Conditioners are designed to either deliver

More information

Z-Plus Temperature/Humidity Chambers

Z-Plus Temperature/Humidity Chambers Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Z-Plus Temperature/Humidity Chambers www.cszindustrial.com Z-Plus Series Temperature/Humidity Chambers Performance You

More information

Remote Conditioners. RC-Series. ZPRC Series

Remote Conditioners.  RC-Series. ZPRC Series RC-Series Remote Conditioners RC Series ZPRC Series www.cszindustrial.com Remote Conditioners Two chambers for the price of one Cincinnati Sub-Zero s dual-purpose RC-Series Remote Conditioners are designed

More information

Benchtop & Compact Test Chambers

Benchtop & Compact Test Chambers MicroClimate Benchtop & Compact Test Chambers www.cszproducts.com MicroClimate Chambers These chambers are designed to provide users with a compact chamber for testing small components and products for

More information

www.cszindustrial.com MicroClimate Chambers Precise Temperature / Humidity Simulation in a Compact Chamber MicroClimate chambers simulate a full range of temperature and/or humidity conditions. These chambers

More information

Altitude Chambers.

Altitude Chambers. Altitude Chambers www.cszproducts.com Altitude Chambers CSZ Altitude Chambers combine temperature and altitude with optional humidity to test basic components or subassemblies for a variety of industries.

More information

halt & hass systems

halt & hass systems halt & hass systems www.cszindustrial.com TIME COMPRESSOR HALT & HASS CHAMBERS Quickly Discover Design Weaknesses CSZ HALT/HASS chambers provide extreme temperature change rates and multi-axis vibration

More information

HALT & HASS Systems.

HALT & HASS Systems. HALT & HASS Systems www.haltandhass.com TIME COMPRESSOR HALT & HASS CHAMBERS Quickly Discover Design Weaknesses CSZ HALT/HASS chambers provide extreme temperature change rates and multiaxis vibration conditions

More information

Stability Chambers & Rooms

Stability Chambers & Rooms www.cszindustrial.com Stability Chambers & Rooms Stability Chambers CSZ Stability chambers & rooms provide a stable, temperature and/or humidity-conditioned environment for worry-free operation with a

More information

Because People Count On Your Products Everyday, You Can Count On Us

Because People Count On Your Products Everyday, You Can Count On Us Because People Count On Your Products Everyday, You Can Count On Us Environmental Simulation Chambers Helping you make Safe & Reliable Products www.cszindustrial.com The Experience You Need THE EXPERIENCE

More information

Helping Make Safe & Reliable Products Because people count on your products everyday

Helping Make Safe & Reliable Products Because people count on your products everyday Helping Make Safe & Reliable Products Because people count on your products everyday Environmental Simulation Chambers Product Guide www.cszindustrial.com The Experience You need CSZ is your one-stop solution

More information

EZT-570S Touch Screen Controller The Next Generation Controller with Smartphone Technology

EZT-570S Touch Screen Controller The Next Generation Controller with Smartphone Technology EZT-570S Touch Screen Controller The Next Generation Controller with Smartphone Technology www.cszindustrial.com EZT-570S Touchscreen Controller The Next Generation Controller with Smartphone Technology

More information

GENERAL DESCRIPTION. LRE.com 1. CHAMBER

GENERAL DESCRIPTION. LRE.com 1. CHAMBER SYSTEM DESCRIPTION! I The ZP-Series Temperature chambers are pre-engineered chambers designed to For Quality Refurbished Equipment provide an environmentwithspecifictemperature (humidity) conditions. The

More information

Benchtop Test Chambers. Temperature and Humidity

Benchtop Test Chambers. Temperature and Humidity Benchtop Test Chambers Temperature and Humidity Compact chambers with extended testing ranges ESPEC's Criterion benchtop chambers offer two sizes and a variety of testing ranges. With many options, they

More information

Benchtop Test Chambers Temperature and Humidity

Benchtop Test Chambers Temperature and Humidity Benchtop Test Chambers Temperature and Humidity Compact chambers with extended testing ranges ESPEC's Criterion benchtop chambers offer two sizes and a variety of testing ranges. With many options, they

More information

TEMPERATURE SHOCK TEST CHAMBERS

TEMPERATURE SHOCK TEST CHAMBERS E SHOCK TEST CHAMBERS TEST STANDARDS VARIOUS TEST POSSIBILITIES Thanks to rapid and high-speed temperature change tests, failures on products which will undergo such extreme impacts can be detected in

More information

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit Packaged Gas/Electric Units Owner s Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Disconnect power at fuse box or service panel before performing

More information

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range The BINDER MKFT series environmental simulation chamber for low temperature

More information

Installation Operation Maintenance Manual Z-Series

Installation Operation Maintenance Manual Z-Series Installation Operation Maintenance Manual Z-Series 56276 REV R 09/2008 INTRODUCTION INTRODUCTION This manual has been tailored to match the specific features and options provided on your Temperature Chamber

More information

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL

More information

Full Scale Battery Tests

Full Scale Battery Tests Full Scale Battery Tests Aircraft response to fires involving large numbers of small lithium batteries Presented to: ALPA 60 th Air Safety Forum By: Harry Webster, FAA Fire Safety Br. Date: August 6, 2014

More information

Specifications Minimum Typical Maximum Unit

Specifications Minimum Typical Maximum Unit Temperature Probe Data Logger with LCD and USB Interface ORDERING INFORMATION Standard Data Logger (Data Logger, 1m Thermistor Probe, Software on CD and Battery) Replacement Battery LASREC028 LASACC001

More information

DP 300 mobile dew point instrument

DP 300 mobile dew point instrument Instruction manual DP 300 mobile dew point instrument For measuring pressure, dew point and atmospheric dew point in different applications: Compressed air plants (refrigeration/ adsorption dryer) Granulate

More information

Hazardous Material Safety Program

Hazardous Material Safety Program Hazardous Material Safety Program Lithium Battery History and Testing Presented By: Date: Discussion Topics Challenges for mitigating lithium battery risks as technology advances What do we know from research

More information

Auto Technology Company Cyclic Corrosion Test Chamber

Auto Technology Company Cyclic Corrosion Test Chamber Auto Technology Company Cyclic Corrosion Test Chamber Built for Versatile and Repeatable Testing The Auto Technology Cyclic Corrosion Test (CCT) Chamber creates a variety of environments in an exposure

More information

Industrial Freezers &

Industrial Freezers & Industrial Freezers & Production Chilling Chambers www.cszindustrial.com Freezers & Chilling Chambers Built to Last for Decades Cincinnati Sub-Zero s Chilling Chambers are premier, ultralow temperature

More information

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C I] WHAT IS INFRARED? Infrared (IR) is a part of electromagnetic spectrum and lies just beyond red color of visible light. Infrared is invisible. However it has properties similar to light i.e. it travels

More information

Packaged Gas/Electric

Packaged Gas/Electric Packaged Gas/Electric Units Owner's Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Failure to follow this warning can result in Disconnect power

More information

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section

More information

Stress Screening Chamber Selection and Implementation

Stress Screening Chamber Selection and Implementation Stress Screening Chamber Selection and Implementation Bruce Peterson Accolade Engineering Solutions 15520 Rockfield Blvd., Suite H Irvine, CA 92618 949-597-8378 www.accoladeeng.com 1.0 Introduction The

More information

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4 TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4 ENVIRONMENTAL ASPECTS.. 6 SPECIAL REQUIREMENTS.. 8 MANUFACTURER CONSIDERATIONS.. 8 SELECTING AN ENCLOSURE AIR CONDITIONER.... 9 2 Although the selection

More information

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990 Page 1 of 6 G90-990 Explosion Venting and Suppression of Bucket Elevator Legs Explosion vents and explosion suppression devices limit the danger and damage associated with grain dust explosions. This NebGuide

More information

Refrigerated Incubator Model and Operating Instructions

Refrigerated Incubator Model and Operating Instructions Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.

More information

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207 EN - english Instructions for installation and operation Mobile humidity meter DP 207 Dear customers, Thank you very much for deciding in favour of the mobile humidity measuring instrument DP 207. Please

More information

www.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION

More information

Advanced Test Equipment Rentals ATEC (2832) Temperature Cycling Chambers Global-N Series

Advanced Test Equipment Rentals ATEC (2832) Temperature Cycling Chambers Global-N Series Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Temperature Cycling Chambers Global-N Series Faster test chambers... The Global-N series chambers from ESPEC provide

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units. SECTION 15650 REFRIGERATION PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units. 4. Air

More information

MEDICAL CHILLER SYSTEMS

MEDICAL CHILLER SYSTEMS Mission Critical Chilled Water Systems Engineered to Exacting Standards Magnetic Resonance Imaging Systems CT Scanners Oncology Linear Accelerators Blood Cooling Systems Precise Laboratory Applications

More information

Condensing Units CUS 15-60

Condensing Units CUS 15-60 Condensing Units CUS 15-60 General Description UNIT IDENTIFICATION AIR COOLED CONDENSING UNIT CUS... Condensing Unit with Propeller Fan and Scroll Compressor 15-60... Model Size D... Double Circuit e.g....

More information

RLD-H10P Refrigerant Leak Detector

RLD-H10P Refrigerant Leak Detector FANs 125, 121 Product/Technical Bulletin RLD-H10P Issue Date 0396 RLD-H10P Refrigerant Leak Detector The RLD-H10P is a professional grade leak detector for use by refrigeration and air conditioning technicians.

More information

Walk in Freezer. Comfortable work environment

Walk in Freezer. Comfortable work environment Temp. Range /Accuracy - (-) 40 C to (+) 60 C /± 0.1 C Temp Uniformity : ± 1 C Standard features include: Temperature uniformity ±0.1ºC Temperature gradient of 1.0ºC Max. No-waste, custom-cut wall panels

More information

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery 99 Washington Street Melrose,

More information

Clean/Dry Rooms for Lithium Ion Battery Manufacturing

Clean/Dry Rooms for Lithium Ion Battery Manufacturing Clean/Dry Rooms for Lithium Ion Battery Manufacturing The most cost effective design concepts The most significant hurdles in implementing those concepts Manufacturing Process The exact reaction that generates

More information

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points Name: Start time: End time: FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points 1. What are the units of the following quantities? (10 points) a. Enthalpy of a refrigerant b. Dryness fraction of

More information

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS ARCTIKO AIMS to be the first and best choice of partner in delivering advanced and customized cooling and freezing solutions

More information

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL FitoTerm & FitoClima temperature and humidity testing chambers offer highly precise and reproducible conditions for climatic

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T20 Model INSTRUCTION MANUAL T-Series Air Conditioner T20 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

FAST CHANGE RATE AND DRIVE-IN CHAMBERS FOR AUTOMOTIVE TESTING. by ESPEC North America Inc

FAST CHANGE RATE AND DRIVE-IN CHAMBERS FOR AUTOMOTIVE TESTING. by ESPEC North America Inc FAST CHANGE RATE AND DRIVE-IN CHAMBERS FOR AUTOMOTIVE TESTING by ESPEC North America Inc Quality is more than a word. History of ESPEC North America 1983 Manufacturing operations started 1990 Consolidation

More information

EL-USB-TC Thermocouple Data Logger with USB Interface

EL-USB-TC Thermocouple Data Logger with USB Interface Thermocouple Data Logger with USB Interface ORDERING INFORMATION Standard Data Logger EL-USB-TC (Data Logger, Measurement Leads, Software on CD and Battery) Replacement Battery K-type Probe BAT 3V6 1/2AA

More information

MODEL IX-WAC AIR CONDITIONERS FOR HAZARDOUS & HIGHLY CORROSIVE AREAS

MODEL IX-WAC AIR CONDITIONERS FOR HAZARDOUS & HIGHLY CORROSIVE AREAS 1.5, 2, 2.5, 3, 3.5, 4, 5 & 6 Ton Industrial Grade Wall Mounted Air Conditioners Unit Application ebco Model IX-WAC Industrial Grade Air Conditioners are designed as a top-of-the-line highly qualified

More information

WOOD CHIP HEATING HPK-RA

WOOD CHIP HEATING HPK-RA WOOD CHIP HEATING HPK-RA -60 Wood Chip Heating HPK-RA -60 TÜV certified 8 0 9 7 Efficiency of all boilers on full and part load operation more than 90%. 6 WOOD CHIP BOILER HPK-RA Description Cell wheel

More information

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE FitoTerm & FitoClima temperature and humidity testing chambers offer highly precise and reproducible

More information

commercial refrigeration products

commercial refrigeration products commercial refrigeration products Evaporators Condensing Units Condensers Air Handlers Fluid Coolers Coils NOTHING BEATS A BALLY Evaporators EC MOTORS Available Half Round Low velocity Two-way low profile

More information

WOOD CHIP HEATING HPK-RA

WOOD CHIP HEATING HPK-RA HPK-RA -60 HPK-RA -60 TÜV certified 8 0 9 7 Efficiency of all boilers on full and part load operation more than 90%. 6 WOOD CHIP BOILER HPK-RA DESCRIPTION Cell wheel Wood chip burner in high-quality heat-resistant

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

Energy Storage Systems Fire Safety Considerations. Howard Hopper, FPE Regulatory Services Program Manager

Energy Storage Systems Fire Safety Considerations. Howard Hopper, FPE Regulatory Services Program Manager Energy Storage Systems Fire Safety Considerations Howard Hopper, FPE Regulatory Services Program Manager Why Energy Storage? Recently, enormous focus has been placed on expanding the energy storage infrastructure.

More information

Thermal Shock Chamber TSE 11

Thermal Shock Chamber TSE 11 Thermal Shock Chamber TSE 11 CAT.NO.E1133-V13 ESPEC offers a compact, but high performance thermal shock chamber ideal for the requirements of test standards of small and low-volume specimen. Equipped

More information

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40 Technical Description Laboratory Climate Test Chamber System Weiss Mat. No.:67592625 Type WKL 34/40 FACTS The test chambers types WTL/WKL with compact exterior dimensions were especially developed for

More information

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax Stress of 5/min. or more achieved with the large-capacity 1800L models. A faster temperature and humidity chamber with 1800 L capacity has been developed for reliability testing of increasingly large display

More information

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications Detailed Working Specifications The Chamber with extremely high fabrication standard, high quality of finish, which matches the performance with emphasis on reliability and economy of use. The use of the

More information

RSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016

RSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016 This Table of Contents lists the complete contents of the RSES s (SAM) issued to date. Section 1 Refrigeration 620-05 Principles of Refrigeration Part 1 620-06 Principles of Refrigeration Part 2 620-67

More information

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T15 Model INSTRUCTION MANUAL T-Series Air Conditioner T15 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

AIR CONDITIONING. Carrier Corporation 2002 Cat. No AIR CONDITIONING Carrier Corporation 2002 Cat. No. 020-016 1. This refresher course covers topics contained in the AIR CONDITIONING specialty section of the North American Technician Excellence (NATE)

More information

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control Ultra-Low Temperature Freezers Series Microprocessor Control Basic Series Solid-State Electronic Control 2 Ultra-Low Freezers Queue Advantage ultra-low temperature freezers create stable -86 C, -50 C and

More information

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T53 Model INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground

More information

Walk-in Test Chambers Panelized & Solid Construction

Walk-in Test Chambers Panelized & Solid Construction Walk-in Test Chambers Panelized & Solid Construction ESPEC s Custom Design Walk-ins Deliver the Chamber Performance & Size You Need Walk-in chambers are complex systems that can push the limits of lab

More information

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter by Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Technical Specifications Brouwer -86 o C Chest STORAGE SPECS UNIT -86 DFC 370-86 DFC 620-86 DFC 820 Capacity L 370 620

More information

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-1-LCD Temperature Data Logger with LCD Temperature Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-1-LCD BAT 3V6 1/2AA FEATURES measurement range USB interface

More information

Cryogenic cooling with CUMULUS LF.

Cryogenic cooling with CUMULUS LF. Cryogenic lyophilisation Cryogenic cooling with CUMULUS LF. Improved performance, high reliability and low maintenance for your lyophilisers. 02 Improving performance of freeze dryers with cryogenic cooling.

More information

Our energy efficient experts and engineers have made ground breaking innovations in this field.

Our energy efficient experts and engineers have made ground breaking innovations in this field. Company Profile Introduction: We are pleased to introduce ourselves as MAFNA Air Technologies Inc., established in 1999. MAFNA Air Technologies Inc, is Canada's leading manufacturer and supplier of Air

More information

TCC-34. Features: TISSUE CULTURE

TCC-34. Features: TISSUE CULTURE www.biochambers.com PROVIDING GROWTH TO RESEARCH. TCC-34 TISSUE CULTURE Tissue Culture chambers and rooms are specifically designed to maximize research area and to provide uniform environmental conditions.

More information

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY C A P A C I T Y R U G G E D, I N D O O R/ R E A D Y T O T O T A L L O C A L M A T C H E D O U T D O O R D E S I G N I N S T A L L S U P P O R T E N V I R O N M E N T A L C O N T R O L Liebert Industrial

More information

Walk-in Test Chambers. Panelized & Solid Construction

Walk-in Test Chambers. Panelized & Solid Construction Walk-in Test Chambers Panelized & Solid Construction ESPEC s Custom Design Walk-ins Deliver the Chamber Performance and Size You Need Walk-in chambers are complex systems that can push the limits of lab

More information

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0

More information

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. I P/N 89104464 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE

More information

Products for Secondary Battery Market

Products for Secondary Battery Market Products for Secondary Battery Market Lithium-ion batteries Electrode blending process Materials are blended and processed to produce slurry for positive and negative electrodes. 1-1 Battery Dry Chamber

More information

A Review of America s First Step Towards the Harmonization of Portable Battery Standards: UL 62133

A Review of America s First Step Towards the Harmonization of Portable Battery Standards: UL 62133 A Review of America s First Step Towards the Harmonization of Portable Battery Standards: UL 62133 John JC Copeland Energy Assurance LLC August 6, 2015 Awareness Overview Tests (current version) Comparison

More information

Chapter-8 Capacity Control of Refrigeration Systems

Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control

More information

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd Abstract This paper presents the design approach adopted for the expansion of a large existing

More information

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER FITOCLIMA 1.000 ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER INTEGRATED CLIMATIC AND VIBRATION FitoTerm & FitoClima temperature and humidity testing chambers

More information

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Igloo Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Igloo More samples, less footprint Laboratory space is valuable. In comparison with the traditional freezers, Telstar

More information

Reach-In. PLanT GROWTh. Reach-In

Reach-In. PLanT GROWTh. Reach-In E7 Reach-In PLanT GROWTh Reach-In E7 Reach-In PLANT GROWTH Product Overview/Applications Conviron s E7 plant growth chamber is a compact yet highly configurable unit that is suitable for a wide variety

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

IceSpy System5. A big deal in the world of large scale environmental monitoring FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS COMPLIANCE REGULATORY

IceSpy System5. A big deal in the world of large scale environmental monitoring FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS COMPLIANCE REGULATORY FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS ASSISTS WITH NATIONAL REGULATORY COMPLIANCE REQUIREMENTS IceSpy System5 A big deal in the world of large scale environmental monitoring Intelligent monitoring and

More information

Plant Growth Chamber MPGR14

Plant Growth Chamber MPGR14 Plant Growth Chamber Product Overview/Applications The provides a 14 ft2 growth area and a 58 inch growth height making this chamber suitable for a range of applications including plant science, bioengineering,

More information

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic

More information

We maintain stock in many of our most popular models for immediate shipment.

We maintain stock in many of our most popular models for immediate shipment. Marine Refrigeration www.rtfmanufacturing.com Equipment Catalog Why Choose RTF Manufacturing? Superior Design RTF Manufacturing Provides State-of-the-Art, Quality-Designed Refrigeration Equipment for the

More information

Membrane Technologies DMD Series Dryers ESM Series Dryers

Membrane Technologies DMD Series Dryers ESM Series Dryers Membrane Technologies DMD Series Dryers ESM Series Dryers Membrane Technologies Energy Saving Compressed Air Dryers People around the globe have relied on Deltech to deliver energy efficiency and value

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

Battery Abuse Fire Testing to SAE J2464. Rich Byczek, Intertek

Battery Abuse Fire Testing to SAE J2464. Rich Byczek, Intertek Battery Abuse Fire Testing to SAE J2464 Rich Byczek, Intertek Agenda Background/purpose of High Temperature Hazard Test Test requirements and parameters Issues and common perceptions Alternate method for

More information

Synergy Controller Application Note 125 January 2016, Revision A Tidal Engineering Corporation 2016

Synergy Controller Application Note 125 January 2016, Revision A Tidal Engineering Corporation 2016 Synergy Quattro Retrofit for VersaTenn III Controllers Introduction Tidal Engineering s Synergy Controller is a family of process control systems designed to drop into virtually any environmental test

More information