1 Exam Prep Plumbing State Contractors Practice Exam 2

Size: px
Start display at page:

Download "1 Exam Prep Plumbing State Contractors Practice Exam 2"

Transcription

1 1 Exam Prep Plumbing State Contractors Practice Exam 2 1 According to Chapter 64E-6, when sizing a grease interceptor used in a restaurant, the correct formula is. A. (S) x (EW 12) x (LF) B. (S) x (GS) x (IW 12) x (LF) C. (S) x (GS/ 12) x (HR) D. (S) x (GS) x (HR) x (12) x (LF) 2. When employees are required to be in trenches feet or more in depth, ladders shall be provided for exit, and such ladders shall require not more than feet of lateral travel. A. 4 feet-30 feet B. 5 feet- 30 feet C. 4 feet-25 feet D. 5 feet-25 feet 3. The minimum flow rate for the hydraulically most remote outlet in a Class II system is. A. 80 gpm B. 100 gpm C. 250 gpm D. 500 gpm 4. Piping shall be supported from the building structure in accordance with. A. Local Code B. Plans C. MSS SP-58 D. MSS SP According to the Plumber's Handbook, the minimum dimensions for a handicapped toilet room are. A. 2 feet by 3 feet B. 3 feet by 4 feet, 4 inches C. 3 feet by 4 feet, 8 inches D. 5 feet by 5 feet 1 Exam Prep Plumbing Practice Exam 2 1

2 6. The MINIMUM clearance from combustible materials for a vent piping connector for domestic-type vent appliances (without a draft hood, and excluding oil appliances labeled for venting with Type L vents) SHALL be. A. 4" B. 6" C. 9" D. 18" 7. Space under an element between 9 inches and 27 inches above the finish floor or ground and shall comply be considered. A. Toe clearance B. Vertical clearance C. Knee clearance D. Turning space 8. The backflow of potentially contaminated water into the potable water system as a result of the pressure in the potable water system failing below atmospheric pressure of the plumbing fixtures, pools, tanks or vats connected to the potable water distribution piping is called. A. Backflow B. Air gap C. Backsiphonage D. Back pressure 9. One- and two-family dwellings shall have which of the following characteristics? A. Be not more than three stories above grade plane in height B. have a separate means of egress C. Both A and B D. Neither 10. According to the Florida Fuel Gas Code, in nonload-bearing partitions a hole may be bored not greater than of the wood stud. A. 25% B. 40% C. 60% D. 75% 1 Exam Prep Plumbing Practice Exam 2 2

3 11. The optimum collector tilt for year-round use for domestic solar water heating in Jacksonville, Florida would be. A. 25 B. 30 C. 38 D According to Chapter 64E-6, the maximum depth from the invert to the drain tile or distributor pipe to the finished ground surface shall not exceed 30" and shall have a earth cover of. A. 6" B. 8" C. 10" D. 12" 13. Class II hazardous locations are those with a presence of: A. combustible dust B. ignitable fibers C. flammable liquids D. explosives 14. Class I systems shall be provided with diameter hose connections. A. 4 inch B. 3 inch C. 2 inch D. 2-1/2 inch 15. Which of the following is not true about oxygen cylinders? A. Grease shall not come in contact with valves or fittings B. Valves should be left open on empty stored cylinders C. Cylinders shall not be stored near heat ducts D. Oxygen shall never be substituted for compressed air 16. According to the Plumber's Handbook, the recommended hot water (gas type) tank size for a 4 bedroom home is gallons. A. 20 B. 40 C. 52 D Exam Prep Plumbing Practice Exam 2 3

4 17. Mechanical joints may be used on soft annealed copper tubing nominal size, and shall conform to ASTM B 2S0. A. Less than 1 3/8" B. Less than 1 1/8" C. 1" D. 7/8" or less 18. In residential dwelling units, the height of water closets shall be permitted to be inches minimum and inches maximum above the finish floor, measured at the top of the seat. A. 16, 18 B. 16, 20 C. 17, 19 D. 15, A 5 acre parking lot will drain off gallons of water after a 1" rainfall. A. 27,043 gallons B. 135,219 gallons C. 150,765 gallons D. 162,914 gallons 20. Administration and enforcement of the Florida Building Code, Residential shall be in accordance with the Florida Building Code,. A. Residential B. Building C. Both A and B D. Neither 21. According to the Florida Fuel Gas Code, a 2 1/2 inch field threaded metallic pipe, threads are required. A. 10 B. 11 C. 12 D What is the angle of incidence when the sun is directly overhead? A. 0 degrees B. 90 degrees C. 180 degrees D. 270 degrees 1 Exam Prep Plumbing Practice Exam 2 4

5 23. According to Chapter 64E-6, a septic tank system shall not be located under buildings or within feet thereof, or within 5 feet of property lines except where property lines abut utility easements which do not contain underground utilities. A. 3 B. 5 C. 7 D When employees are required to be in trenches of or more, an adequate means of exit such as a ladder or steps shall be provided. A. 3 feet B. 4 feet C. 5 feet D. 6 feet 25. Horizontal piping hangers shall be spaced at a maximum separation distance. A. of 5 feet B. of 10 feet C. of 15 feet D. according to NFPA Each section of the piping in medical gas and vacuum systems shall be subject to an initial pressure test and examined for leakage. The test pressure for gases shall be 1.5 times the system working pressure but not less than a gage pressure of. A. 60 psi B. 100 psi C. 125 psi D. 150 psi 27. According to the Plumber's Handbook, one watt equals B.T.U.s. A. 3.4 B. 3.6 C. 3.8 D. 4 1 Exam Prep Plumbing Practice Exam 2 5

6 28. Condensate waste and drain line size shall be not less than internal diameter and shall not decrease in size from the drain pan connection to the place of condensate disposal. A. 3/8 inch B. 1/2inch C. 3/4 inch D. 1 inch 29. Drinking Fountains for standing persons shall be inches min and 43 inches max above the finish floor/ground. A. 38 B. 28 C. 30 D According to code, the maximum elevation of effluent in a sewage lift station will be, when the inlet invert elevation is '. A ' B ' C ' D ' 31. A building sewer is required to be water tight at all points. A. True B. False 32. According to the Florida Fuel Gas Code, the minimum clearance from the top of an open-top broiler unit to the ventilation hood is inches. A. 24 B. 28 C. 32 D The solar return on a standard electric water heater should have a dip tube to return heated water approximately below the upper element's thermostat. A. 2 inches B. 3 inches C. 4 inches D. 6 inches 1 Exam Prep Plumbing Practice Exam 2 6

7 34. According to Chapter 64E-6, a septic tank system should be checked for occasional cleaning at least once every year(s) if garbage grinders are discharging into the tank to determine if sledge needs to be removed. A. 1 B. 2 C. 3 D In excavations where employees must enter, excavated or other materials may be stored: A. two feet from the edge of the excavation B. one foot from the edge of the excavation if properly retained C. one foot from the edge of the excavation D. A or B 36. The organization responsible for approving equipment and installations is. A. National Fire Prevention Association B. The Builder of Record C. The Authority Having Jurisdiction D. The Architect 37. When cleaning the interior surfaces of level I distribution piping and controls on site, clean, hot wateralkaline solution, such as sodium carbonate or trisodium phosphate may be used at a rate of. A. 1 gallon to 3 gallon of potable water B. 1 gallon to 4 gallons of potable water C. 1 gallon to 5 gallons of potable water D. 1 pound to 3 gallons of potable water 38. According to the Plumber's Handbook, a water service pipe must be placed in a separate trench from that of the sewer pipe and must be separated by at least feet. A. 5 B. 10 C. 15 D Exam Prep Plumbing Practice Exam 2 7

8 39. Which of the following is not permitted as a joint in fuel oil piping? A. Threaded joints B. Brazed joints C. Mechanical joints D. Unions requiring gaskets or packings, right or left couplings, and sweat fittings employing solder having a melting point of less than 1,000 degrees 40. The seat height of a water closet shall be inches minimum and inches maximum above the finish floor, measured at the top of the seat. A. 16, 18 B. 16, 20 C. 17, 19 D. 15, According to code, a fitting is prohibited for use in the water distribution piping. A. compression B. saddle-type B. threaded joint D. soldered joint 42. piping, installed through holes or notches in studs, joists, rafters or similar members less than 1 1/2 inches from the nearest edge of the member, required protection by steel shield plates. A. Cast-iron B. Galvanized steel C. Either A or B D. Neither 43. According to the Florida Fuel Gas Code, when testing the piping system the minimum test pressure shall not be less than psig. A. 3 B. 30 C. 125 D. Twice the working pressure 44. What is the turnover time for a pool heating system using a gas or oil heater with100 feet of 2 inch diameter pipe and a 1 hp pump? A. 9 hours B. 8 hours C. 7.2hours D. 8.6 hours 1 Exam Prep Plumbing Practice Exam 2 8

9 45. According to Chapter 64E-6, the absorption bed for a three bedroom private dwelling where the percolation rate is 1 " in 9 minutes shall have a minimum area of square feet (Select the closest answer). A. 105 B. 165 C. 300 D The greatest angle above the horizontal plane for Type A soil is degrees. A. 34 degrees B. 45 degrees C. 53 degrees D. 90 degrees 47. Which system has piping that supplies both hose connections and automatic sprinklers? A. dual supply B. dual feed C. dual purpose D. combined 48. Which of the following is not a level 1 pipe labeling requirement? A. At intervals of not more than 20 feet B. At least once in or above every room C. On both sides of walls or partitions penetrated by the piping D. At least once every other story height traversed by risers 49. According to the Plumber's Handbook, a 2-inch pipe requires inch pipe wrench. A. 6 or 8 B.10 C. 14 D SHALL NOT be used to leak test a system. A. R-22 B. Nitrogen C. Oxygen D. R-12 1 Exam Prep Plumbing Practice Exam 2 9

10 51. The minimum number of drinking fountains that shall be provided is. A. One B. Two C. Three D. Four 52. According to code, a crown vent shall not be installed within of a 3" trap weir. A. 9" B. 8" C. 6" D. 3" 53. Footings extend below the 45-degree bearing plane of the bottom edge of a wall or footing when trenching is installed parallel to the footings. A. shall B. shall not 54. When combining spaces on the same story, each opening shall have a net free area of square inch(es) per 1,000 Btu/hr of the total input rating of all appliances in the space. A. 1 B. 2 C. 3 D How many heat traps should be installed on the storage tank piping? A. 1 B. 2 C. 3 D According to Chapter 64E-6, septic tank systems should not be located within feet of any private water supply well or within 100 feet of any public water supply well. A. 25 B. 50 C. 75 D Exam Prep Plumbing Practice Exam 2 10

11 57. Sloping or benching for excavation than feet deep shall be designed by a registered professional engineer. A. 10 B. 15 C. 20 D A connection through which the fire department can pump water into a standpipe is. A. a fire department connection B. a standpipe riser connector C. an accessible inlet connection D. a drainage outlet fitting 59. Flexible connectors of other than all-metal construction used to connect outlets of pressure regulators to fixed piping shall not exceed in length, for a level 3 piping system. A. 24" B. 48" C. 60" D. 72" 60. According to the Plumber's Handbook, sand filters used for swimming pools must have a backwash rate of not less than g.p.m. per square foot of filter area. A. 10 B. 12 C. 14 D Generally, appliances located in public garages, motor fuel-dispensing facilities, repair garages or other areas frequented by motor vehicles, shall be installed a minimum of above the floor. A. 3 feet B. 4 feet C. 6 feet D. 8 feet 62. According to code, process tanks shall discharge into a drainage system through. A. a back-flow valve B. a drum trap C. a direct waste with a trap D. an indirect waste pipe with an air gap 1 Exam Prep Plumbing Practice Exam 2 11

12 63. What is the minimum diameter for fixture tail pieces for sinks, dishwashers, laundry tubs, bathtubs and similar fixtures? A. 1/2 inch B. 1 inch C. 1 1/2 inches D. 2 inches 64. Tests requiring a pressure of 10 psig or less shall utilize a testing gauge having increments of psi or less? A..10 B. 1.0 C. 10 D According to Florida Rules: Chapter 64E-6, when a private potable well is utilized, the maximum daily sewage flow allowance is multiplied by gallons per acre per day? A. 1,000 B. 1,500 C. 2,000 D. 2, The standpipe system that relies on a fire department connection to supply the system is. A. an automatic standpipe system B. a manual standpipe system C. a semiautomatic standpipe system D. a single zone standpipe system 67. 1" nominal copper tubing for level 3 shall be supported from the building structure a maximum of feet on center. A. 6' B. 7' C. 8' D. 9' 68. According to the Plumber's Handbook, the minimum size waste and overflow for bathtubs is inch(es). A. 1 B. 1 1/2 C. 2 D. 3 1 Exam Prep Plumbing Practice Exam 2 12

13 69. According to code, a waste stack can receive waste from. A. water closets B. any plumbing fixture C. residential plumbing fixtures only D. fixtures other than water closets and urinals 70. What is the minimum utility space required for fixtures with concealed slip-joint connections? A. 8 inches B. 12 inches C. 16 inches D. 20 inches 71. Gaseous hydrogen piping shall be sized in accordance with methods? A. SMACNA B. NFPA 58 C. NFPA 54 D. Approved engineering 72. According to Florida Rules: Chapter 64E-6, when designing a drain field what is the minimum percentage of unobstructed land area in relationship to the drain field? A. 75 % B. 100 % C. 150 % D. 200% 73. According to the Plumber's Handbook, if the size of the fixture drain is 1-1/2", the maximum distance of the fixture trap from the vent opening is. (Based on the International Plumbing Code). A. 2 B. 3 C. 4 D According to code, a central vacuum (fluid suction) system of the disposal type shall be: A. directly connected to the sanitary drainage system through a trapped waste B. indirectly connected to the sanitary drainage system through an air gap C. connected through an approved interceptor D. connected with a backwater valve 1 Exam Prep Plumbing Practice Exam 2 13

14 75. How many inches above the trap weir are standpipes required to extend? A. 12 inches B. 22 inches C. 32 inches D. 42 inches 76. According to code, a 2" horizontal drain pipe shall fall at least, in a 35 foot run. A. 4-3/8 inches B. 6-5/8 inches C. 7-3/8 inches D. 8-3/4 inches 77. A backflow prevention device which includes a spring loaded check valve and a spring loaded vacuum breaker to prevent the backflow of irrigation system to the water source is called. A. Pressure relief valve B. Pressure vacuum breaker C. Block system D. Air gap prevention valve 78. A solar water heating system would have its air vent located? A. at the midpoint of the storage tank B. vertical, in the uppermost part C. immediately above the drain valve D. air vents are not part of the system 79. According to code, the adapter fitting for PVC pipe to cast iron hub pipe may be a. A. caulked joint B. increaser bushing C. expansion joint D. ground joint 80. According to code, copper vent pipe flashing shall weigh not less than per square foot. A. 8 ounces B. 10 ounces C. 12 ounces D. 16 ounces 1 Exam Prep Plumbing Practice Exam 2 14

15 1 Exam Prep Plumbing State Contractors Practice Exam 2 Answers Book Section/Page 1. B 64-E (8.(d.(1. 2. C OSHA (9)(2) 3 B NFPA C NFPA 99, C Plumber s Handbook D FBC - Mechanical, 2014 Table C FBC Accessibility, C FBC Plumbing 202, definitions 9. C FBC Residential R C FBC- Fuel Gas, B Solar Water & Pool Heating Manual 1-11, North Florida 12. A 64-E A OSHA D NFPA B NFPA 99, B Plumber s Handbook D FBC - Mechanical, D FBC Accessibility, B FBC Plumbing Solution: Mathematics 1 Acre = 43,560 sf x 5 acres = 217,800 sf 217,800 x.083' = 18,077 cf x 7.48 = 135,219 gallons Note: 1 "/12" =.083' 1 cf = 7.48 gallons 20. B FBC Residential R C FBC- Fuel Gas, 2014 Table A Solar Water & Pool Heating Manual 1-5, Figure 3, 0 degrees 23. B 64-E ( B OSHA (c.( D NFPA D NFPA 99, A Plumber s Handbook C FBC - Mechanical, A FBC Accessibility, D FBC Plumbing Solution: " / 12" =.166' ' -.166' = 142' 31. A FBC Residential P Exam Prep Plumbing Practice Exam 2 15

16 32. A FBC- Fuel Gas, D Solar Water & Pool Heating Manual 3-23 #7 34. A 64-E ( D OSHA (j. ( C NFPA D NFPA 99, A Plumber s Handbook D FBC - Mechanical, , , C FBC Accessibility, B FBC Plumbing C FBC Residential P A FBC- Fuel Gas, C Solar Water & Pool Heating Manual 5-21 Table 7.1, gas or oil, 100' - 2", 1 hp, A 64-E Table I Solution: 100 Gallons/Day/Bedroom 3 Bedrooms = 300 Gal/Day Table 3 (5-10 Minutes Inch = x 0.35 = C OSHA Table B D NFPA D NFPA 99, (1)(2)(3)(4) 49. D Plumber s Handbook C FBC - Mechanical, B FBC Accessibility, C FBC Plumbing Note: not within two pipe diameters, 2 x 3" = 6" 53. B FBC Residential P A FBC- Fuel Gas, B Solar Water & Pool Heating Manual 3-23 Note: #4 (1-cold water inlet) (1-hot water supply) 56. C 64-E (1.(a. 57. C OSHA Table B-1 note 58 A NFPA C NFPA 99, B Plumber s Handbook D FBC - Mechanical, D FBC Plumbing C FBC Residential P A FBC- Fuel Gas, B 64-E (7)(c) 66. B NFPA C NFPA 99, 2012 Table B Plumber s Handbook D FBC Plumbing B FBC Residential P Exam Prep Plumbing Practice Exam 2 16

17 71. D FBC- Fuel Gas, A 64-E (4) 73. B Plumber s Handbook A FBC Plumbing D FBC Residential P D FBC Plumbing Table 704.1, Solution: 1/4" per foot, 35' x.25" = 8.75" 77. B FBC Plumbing Appendix F, definitions 78. B Solar Water & Pool Heating Manual 2-37, Figure A FBC Plumbing A FBC Plumbing Exam Prep Plumbing Practice Exam 2 17

1 Exam Prep Plumber s Handbook Tabs and Highlights

1 Exam Prep Plumber s Handbook Tabs and Highlights 1 Exam Prep Plumber s Handbook Tabs and Highlights These 1 Exam Prep Tabs are based on the Plumber s Handbook Revised 2006. Each Tabs sheet has five rows of tabs. Start with the first tab at the first

More information

Level I Chapter 1 Worksheet

Level I Chapter 1 Worksheet Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the

More information

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. ICP Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A 1 inch diameter faucet, where the inside edge of the spout opening is 2.5 inches away

More information

1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)

1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors) 1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors) 1. What is the minimum diameter for a non-hydraulically calculated Class III fire standpipe that is part of a combined

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 9 Indirect Waste Piping and Special Wastes 9.1 INDIRECT WASTES 9.1.1 General Drains from fixtures, fixture compartments, equipment, appliances, appurtenances, and other devices requiring protection

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor) 1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor) 1. For year-round use, a collector tilt of degrees works best for a project located in Tampa, Florida.

More information

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A vent stack handling 25 dfu s with a developed length of 35 feet shall be inches minimum

More information

Sanitary Drainage Systems

Sanitary Drainage Systems 11.1 MATERIALS See Section 3.1. Sanitary Drainage Systems 11.2 BUILDING SEWERS AND BUILDING DRAINS 11.2.1 Sewer or Drain in Filled Ground Chapter 11 Building sewers or building drains that are installed

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

2016 Plumbing Supplemental Plan Review List

2016 Plumbing Supplemental Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for

More information

MATERIALS Traps TRAPS. No. IPC IRC Description

MATERIALS Traps TRAPS. No. IPC IRC Description MATERIALS Traps TRAPS MAX " MAX 0" No. IPC IRC Description 00. P0.6 00. P0.6 00. P0. 00. () P0.6 Exc. Vertical distance from fixture to the trap weir can not exceed ". Horizontal distance from the fixture

More information

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. The minimum air gap for a fixture with an effective open of 1/2", located away from a

More information

GASEOUS HYDROGEN SYSTEMS

GASEOUS HYDROGEN SYSTEMS CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 GENERAL 701.1 Scope. The installation of gaseous hydrogen systems shall comply with this chapter and Chapters 30 and 35 of the Fire Compressed gases shall

More information

INSPECTION OF COMMERCIAL KITCHEN PLUMBING

INSPECTION OF COMMERCIAL KITCHEN PLUMBING INSPECTION OF COMMERCIAL KITCHEN PLUMBING 801.1 SCOPE Food-handling establishments 2 - by John Williams, Jr. Plumbing Control Supervisor Onondaga County Water Environment Protection Commercial Kitchens

More information

Building Utilities 1 Plumbing and Sanitary Systems

Building Utilities 1 Plumbing and Sanitary Systems Building Utilities 1 Plumbing and Sanitary Systems Taken from UST Architecture exams by Arch. Rafael Alli Recommended review material for UST Preboard Exam Prepared by: arkireviewph.multiply.com Types

More information

PLUMBING FIXTURES CHAPTER 27

PLUMBING FIXTURES CHAPTER 27 CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS P2701.1 Quality of fixtures. Plumbing fixtures, faucets and fixture fittings shall be constructed of approved materials,

More information

PLUMBING REQUIREMENTS

PLUMBING REQUIREMENTS PLUMBING REQUIREMENTS This handout is a compilation of the standard requirements based on the State Plumbing Code and City Ordinance for projects of this type. This information sheet does not contain all

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

2015 UPC Chapter 8 Indirect Wastes RV

2015 UPC Chapter 8 Indirect Wastes RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)* CHaPTeR 10 TRaPS and INTeRCePTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 22 40 00 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Faucets for lavatories, bathtubs, bathtub/showers, showers and sinks. 2. Flushometers. 3. Toilet

More information

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Ohio Administrative Code Rule Number OPC Section IPC origin Reason for proposed 4101:3-2-01 Alternate on-site 2015 Added definition

More information

1 Exam Prep Florida Building Code-Mechanical Tabs and Highlights

1 Exam Prep Florida Building Code-Mechanical Tabs and Highlights 1 Exam Prep Florida Building Code-Mechanical Tabs and s These 1 Exam Prep Tabs are based on Florida Building Code-Mechanical, 2014. Each 1 Exam Prep tabs sheet has five rows of tabs. Start with the first

More information

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2 CHAPTER 10 TRAPS AND INTERCEPTORS < 1001.0 Traps Required. Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.1, shall be separately trapped by an approved type

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION................1 101.0 Title, Scope, and General...........1 101.1 Title............................1 101.2 Purpose.........................1 101.3 Plans Required...................1

More information

APPENDIX J ILLUSTRATIONS

APPENDIX J ILLUSTRATIONS The following figures have been included in the 1994 edition of the Standard Plumbing Code to aid in interpreting this code. The figures are not to be construed as superseding the written text, but merely

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION.............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

1. You are required to use a 20 foot ladder placed up against a building that is 40 high. At what

1. You are required to use a 20 foot ladder placed up against a building that is 40 high. At what This practice exam will require you to have a calculator, pencil, scrap paper, a copy of the 2005 National Plumbing Code and will contain many similar questions as the current Plumbing Red Seal trade certification.

More information

MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST

MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST Rev: 10/23/08 MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST The following standards apply to constructing, renovating or converting buildings to use for preparing, processing, storing or

More information

Special Requirements For Health Care Facilities

Special Requirements For Health Care Facilities Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010 General: 1) (Q) Who enforces the cutting and notching requirements found in the plumbing code? (A) The plumbing inspector would question the contractor initially. A building inspector would either take

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

STACKS AND STACK VENTS

STACKS AND STACK VENTS CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing

More information

TABLE OF CONTENTS. Part I Administrative... 1

TABLE OF CONTENTS. Part I Administrative... 1 Part I Administrative............................ 1 CHAPTER 1 ADMINISTRATION............... 1 R101 Title, Scope and Purpose.................... 1 R102 Applicability.............................. 1 R103

More information

PLAN REVIEW SUBMITTAL GUIDE

PLAN REVIEW SUBMITTAL GUIDE PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide

More information

Test Code: 8117 / Version 1

Test Code: 8117 / Version 1 Pennsylvania Customized Assessment Blueprint Plumbing Technology/Plumber PA Test Code: 8117 / Version 1 Copyright 2012. All Rights Reserved. General Assessment Information Plumbing Technology/Plumber PA

More information

HVAC Equipment Access Equipment Location

HVAC Equipment Access Equipment Location City of Lancaster- Building Department 121 East Chestnut Street, Suite 102, Lancaster, Ohio 43130-3825 (740) 687-6649, Fax (740) 681-5030 Web site: www.ci.lancaster.oh.us/dept/building HVAC Heating, Ventilating,

More information

A GUIDE TO PASSING THE PLUMBING EXAM

A GUIDE TO PASSING THE PLUMBING EXAM A GUIDE TO PASSING THE PLUMBING EXAM BASED ON THE INTERNATIONAL PLUMBING AND FUEL GAS CODES WRITTEN BY JOHN WHITE REVISED 2014 2007-2014 This manual is the sole property of Energy Marketing Services. No

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

ENERGY MARKETING SERVICES

ENERGY MARKETING SERVICES 1 IMPORTANT STUFF This manual has been designed as a supplemental aid for students preparing to take the Plumbing Exam based on the international codes. It is not intended to replace any manuals or material

More information

2012 INTERNATIONAL FUEL GAS CODE VENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS 2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with

More information

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01 CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING Test Code: 5924 Version: 01 Specific competencies and skills tested in this assessment: Safety Follow rules for fire safety Follow rules for housekeeping

More information

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof. CHAPTER 9 VENTS SECTION 90 GENERAL run undiminished in size and as directly as possible from the building drain through to the open air above the roof. 90. Scope. The provisions of this chapter shall govern

More information

PLUMBING FIXTURES Reserved

PLUMBING FIXTURES Reserved CHAPTER 27 PLUMBING FIXTURES Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 395R This page left intentionally blank. 396R 2003 INTERNATIONAL RESIDENTIAL CODE SECTION P2708 SHOWERS P2708.1 General. Shower

More information

plumbing for greywater

plumbing for greywater plumbing for greywater october 2015 christina bertea ~union trained journeywoman plumber (1978) ~plumbing contractor (1996) ~greywater action singingwater@jps.net plumbing for greywater basic parts of

More information

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used by

More information

PLUMBING INSTALLATIONS

PLUMBING INSTALLATIONS PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT PLUMBING INSTALLATIONS A homeowner guide to plumbing requirements for single-family dwellings November 2017 contents Permit Requirements... 3 Inspection Requirements...

More information

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R CHAPTER 31 VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R This page left intentionally blank. 426R 2003 INTERNATIONAL RESIDENTIAL CODE For SI: PIPE SIZE (inches) TABLE P3107.3 COMMON VENT SIZES

More information

CHAPTER VI BUILDING PLUMBING

CHAPTER VI BUILDING PLUMBING CHAPTER VI BUILDING PLUMBING 6.1. INTRODUCTION The chapter covers questions related to water demand, distribution and drainage. The basic principles for planning and installing common plumbing systems

More information

APPENDIX L ALTERNATE PLUMBING SYSTEMS

APPENDIX L ALTERNATE PLUMBING SYSTEMS ALTERNATE PLUMBING SYSTEMS L 1.0 General. L 1.1 Applicability. The intent of this appendix is to provide clarification of procedures for the design and approval of engineered plumbing systems, alternate

More information

2012 UPC Chapter 5 Water Heaters RV

2012 UPC Chapter 5 Water Heaters RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY a. Only potable water shall be supplied to plumbing fixtures used for drinking, bathing, culinary use or the processing of food, medical or pharmaceutical

More information

2015 MPC, MMC and IFGC Significant Changes

2015 MPC, MMC and IFGC Significant Changes 2015 MPC, MMC and IFGC Significant Changes Based on the 2015 Michigan Plumbing Code, (MPC), the 2015 Michigan Mechanical Code (MMC) and the 2015 International Fuel GaS Code (IFGC) Purpose This program

More information

A. This Section includes the following domestic water piping specialties:

A. This Section includes the following domestic water piping specialties: SECTION 221119 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE 1. BUILDING FEES: 1 AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE ESTABLISHMENT OF FEES PURSUANT TO N.J.A.C.

More information

2009 IPC ,IMC Q &A ANDIFGC

2009 IPC ,IMC Q &A ANDIFGC 2009 IPC,IMC ANDIFGC Q &A TABLE OF CONTENTS PREFACE.... ix ABOUT THE INTERNATIONAL CODE COUNCIL...x IPC CHAPTER 1 SCOPE AND ADMINISTRATION...1 Section 101 General... 1 Section 102 Applicability... 1 Section

More information

Chapter 4: Fixtures, Faucets & Fittings:

Chapter 4: Fixtures, Faucets & Fittings: Table of Contents Chapter 1 Administration 0 Chapter 2 Definitions 0 Chapter 3 General Regulations 0 Chapter 4 Fixtures, Fau & Fit. 12 Chapter 5 Water Heaters 14 Chapter 6 Water Supply & Dist. 10 Chapter

More information

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, JUNE 05 LICENSED PLUMBER INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed

More information

Mechanical Appliance and Equipment Inspection Checklist

Mechanical Appliance and Equipment Inspection Checklist 34 2015 IRC Performing Residential Mechanical s Mechanical Appliance and Equipment Checklist Inspect Mechanical Appliance and Equipment Comments / I. Identify possible mechanical appliance and equipment

More information

CHAPTER 9 VENTS SECTION

CHAPTER 9 VENTS SECTION CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing

More information

ASME STANDARDS IN MODEL CODES

ASME STANDARDS IN MODEL CODES STANDARDS IN MODEL CODES ASME Name Model Code With Year of Referenced IPC IRC UPC 2009 NSPC A112.1.2 Air Gaps in Plumbing 2004 2004 2004 2004 A112.1.3 Air Gap Fittings For Use With Plumbing, Appliances

More information

Pipe Sizing Table. Hydraulic Load Served (fixture units)

Pipe Sizing Table. Hydraulic Load Served (fixture units) MODULE 1 INTRODUCTION Notes: A Pipe Type Horizontal branch Pipe Sizing Table Hydraulic Load Served (fixture units) Size (in.) Code Reference 2 + 1.5 = 3.5 2 7.4.9.1.(1) B Soil stack 13.5 + 13.5 = 27 3

More information

1 Exam Prep. Questions and Answers

1 Exam Prep. Questions and Answers 1 Exam Prep NFPA 14: Standard for the Installation of Standpipe and Hose Systems Questions and Answers 1. According to the NFPA-14, class I standpipes shall be at least inches in size. A. 2" 1/2" C. 3"

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

PLUMBING CURRICULA OUTLINE

PLUMBING CURRICULA OUTLINE PLUMBING CURRICULA OUTLINE CORE CURRICULUM 2015 Basic Safety (Construction Site Safety Orientation) (12.5 Hours) (Module ID 00101-15) Presents basic jobsite safety information to prepare workers for the

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#58619/Page 1/November 1, 2017 PLUMBING Executive Summary: Presently, the Plumbing Systems serving the building are cold water, hot water, sanitary, waste and vent system, storm drain piping, and natural

More information

Structural Guidelines. Food Service Establishments. Retail Food Stores

Structural Guidelines. Food Service Establishments. Retail Food Stores Structural Guidelines for Food Service Establishments and Retail Food Stores Jefferson County Department of Health Food & Lodging Protection Division 1 Before construction or remodeling of a food service

More information

Building Permit Fees (cont.)

Building Permit Fees (cont.) Approved by City Council January 2017 Building Permit Fees (cont.) Windows Fee (1 Only) $84.03 (2 Windows) $105.04 (3 10) $189.07 (11 20) $378.14 (21 50) $567.21 (51 100) $756.28 (100 200) $945.34 (200

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

C O D E S & A M M E N D M E N T S

C O D E S & A M M E N D M E N T S SEVIER COUNTY UTILITY DISTRICT SEPTEMBER 2, 2014 Sevier County Utility District has adopted the 2009 International Fuel Gas Code for gas inspections. The following pages contain frequently used codes and

More information

Denotes a new question! Denotes a revised/revisited question. September 2009 General:

Denotes a new question! Denotes a revised/revisited question. September 2009 General: General: 1) (Q) What does a contractor/permit holder have to supply for an inspection? (A) Section 107.2 of the NC Administrative Code states that it is the duty of the permit holder to provide access

More information

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X X

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X X CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 10 - TRAPS AND INTERCEPTORS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority

More information

HOME INSPECTION CHECKLIST

HOME INSPECTION CHECKLIST HOME INSPECTION CHECKLIST Date: Page 1 of 9 Client Name: Address: Tel No: Surname: Email: A WATER METER 1 Is the water meter visible YES NO 2 Water meter registers when water is drawn YES NO 3 Water meter

More information

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT SECTION 901 GENERAL 901.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration

More information

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE No. 9195 CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2007. All rights reserved. No part of this publication may be reproduced by any means without

More information

Notable Changes in the Mechanical Codes

Notable Changes in the Mechanical Codes Notable Changes in the Mechanical Codes July 2004 The following are some of the changes between the 1997 Uniform Mechanical Code and the 2003 International Mechanical Code(M) and the 2003 International

More information

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2017. All rights reserved. No part of this publication may be reproduced by

More information

Mechanical System Description

Mechanical System Description 1. Building Description: Mechanical System Description The building is a Type-1B construction, 9-levels, non-high rise building with 67 affordable family housing units. The first level of the structure

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

2015 IPC, IMC and IFGC Significant Changes

2015 IPC, IMC and IFGC Significant Changes Accreditation 2015 IPC, IMC and IFGC Significant Changes Based on the International Plumbing Code (IPC ), the International Mechanical Code (IMC ) and the International Fuel Gas Code (IFGC ) The International

More information

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors.

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors. The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors. You can complete the test by printing a hard copy, or

More information

DEFINITIONS CHAPTER 2

DEFINITIONS CHAPTER 2 CHAPTER 2 DEFINITIONS SECTION PC 201 GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter.

More information

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock.

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock. Plumbing Plumbing may be defined as practice, materials, and fixtures used in the installation, maintenance, and alteration of all piping, fixtures, appliances, and appurtenances in connection with sanitary

More information

CHIMNEYS AND VENTS CHAPTER 8

CHIMNEYS AND VENTS CHAPTER 8 CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

REGISTRATION EXAMINATION, NOVEMBER 2011 CERTIFYING PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, NOVEMBER 2011 CERTIFYING PLUMBER ANSWER SCHEDULE No. 9195 REGISTRATION EXAMINATION, NOVEMBER 2011 CERTIFYING PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2011. All rights reserved. No part of this publication may be reproduced

More information

$ Each additional variance per petition. $ All Other Zoning Districts: One variance per petition

$ Each additional variance per petition. $ All Other Zoning Districts: One variance per petition 2015 SCHEDULE COMMUNITY DEVELOPMENT DEPT. ENGINEERING PLAN REVIEW Single Family New Construction All Other Plan Reviews Minimum Engineering Fee Planned Unit Development - PUD: Step #1: Step #2: See Site

More information

Inspection Checklist Mechanical Rough in

Inspection Checklist Mechanical Rough in Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and

More information

Chapter FUEL GAS CODE*

Chapter FUEL GAS CODE* Chapter 19.09 FUEL GAS CODE* * Editors Note: Serial No. 2004-31, 1, adopted Oct. 11, 2004 amended Title 19 in its entirety to read as herein set out. See the editor's note at Tit. 19 and also the Code

More information

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.0 General. 2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.1 Applicability. This chapter shall govern the materials, design, and installation of indirect waste piping, receptors, and connections; and

More information

Plumber Level 3 Rev. May 2011

Plumber Level 3 Rev. May 2011 Level 3 C1 Commercial Sanitary Drainage Systems Duration: 16 hours 10 hours 6 hours This unit of instruction is designed to provide the Plumber apprentice with the basic knowledge and understanding of

More information

Building Department Informational Handout

Building Department Informational Handout City of Sonoma Building Department Informational Handout Residential Water Heaters Handout No: 15 Revised: 4/26/18 A water heater is an appliance designed to supply hot water and is equipped with automatic

More information

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES 2.05 PLUMBING GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.05 It is expected that the plumbing design professional will conform to accepted good engineering design practices.

More information

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant. SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this

More information

LOCAL AMENDMENTS TO THE UNIFORM PLUMBING CODE 2012 EDITION

LOCAL AMENDMENTS TO THE UNIFORM PLUMBING CODE 2012 EDITION CHAPTER 23.25 LOCAL AMENDMENTS TO THE UNIFORM PLUMBING CODE 2012 EDITION Sections 23.25.100 Local amendments to the Uniform Plumbing Code, 2012 Edition. 2 23.25.102-103 Delete.... 3 23.25. 204.0 "B" definitions....

More information