Pump assembly Instruction manual

Size: px
Start display at page:

Download "Pump assembly Instruction manual"

Transcription

1 Instruction manual EN Version 2.0 /Release 06/2012

2 Table of content 1 Key background information Limitation of liability Responsibilities of the operator Documentation Contents and structure Labelling system used in the documentation Target group Replacing wear parts Safety Important safety notices Instructions for correct use Area of use Environmental conditions relevant to safety Observance of the operating instructions Residual risks and safety measures Setup Assembly and commissioning Safety Assembly Initial operation Maintenance Safety Recommended maintenance intervals Maintenance works Dismantle the circulation pump Install the circulation pump Dismantle the 3-way mixer Install the 3-way mixer Servomotor 3-way mixer Change the supply and return flow Technical data Decommissioning, recommissioning Decommissioning Recommissioning Dismantling Disposal Safety Disposal...19 Page 2 Version /2012

3 1 Key background information 1.1 Limitation of liability The contents of these operating instructions have been created with due consideration of applicable legislation and standards. The device has been developed in accordance with the technological state of the art 1. The manufacturer accepts no liability for damage resulting from: X X X X X X Disregard for or non-compliance with the operating instructions Deliberate misuse Incorrect use The use of untrained professionals (for maintenance and repair work, etc.) Technical modifications to the device that have not been discussed with the manufacturer. Use of spare parts that have not been approved by the manufacturer 1.2 Responsibilities of the operator The safety, accident prevention and environmental protection regulations applicable to the area in which the device is used must be complied with. The following is of particular relevance: X X X The operator must ensure that these operating instructions are available for the entire life cycle of the. The operator must ensure that the maintenance intervals described in these operating instructions are complied with. The operator must ensure that all safety devices are being checked for proper function and completeness. notice When assembling and operating the, be aware of country-specific standards and guidelines. 1.3 Documentation Contents and structure These operating instructions are an integral part of the device. They contain instructions and information regarding the safe use of the device and must be made available to all users for the device's entire life cycle. These operating instructions are intended for use by trained professionals. 1 Technical modifications reserved! 06/2012 Version 2.0 Page 3

4 1.3.2 Labelling system used in the documentation The following types of alert are used: Alert type Representation Meaning Acute danger of death danger Dangerous situation that will inevitably cause death or severe injury if it is not avoided Risk of death and severe injury warning Dangerous situation that may cause severe injury or death if it is not avoided Risk of mild to moderate injury caution Dangerous situation that may cause mild to moderate injury if it is not avoided Information, tips to make operation easier notice Indicates information that does not relate to personal hazards, e.g. warnings regarding material damage $ $ Indicates a general safety notice Indicates an Indicates the consequences of an action 1.4 Target group These operating instructions are intended for use by trained professionals. The operator of this device must ensure that suitable and safe conditions are in place as described in these operating instructions. Professional Trained expert who understands the risks of the and who is familiar with the technology used in the device. Professionals are trained and capable of assembling, maintaining and repairing the device. 1.5 Replacing wear parts Be aware that the contains parts which, depending on how frequently and how much they are used, will be subject to technology-related wear and tear, even if they are cared for and maintained properly. Mechanical parts and components that come into contact with hot water and steam are particularly affected by this, such as hoses, gaskets, valves, etc. Wear-related defects of course do not represent faulty workmanship and are therefore not covered by the warranty or guarantee; regardless of this, faults and malfunctions must always only be rectified by trained professionals. For more information, contact your dealer. Page 4 Version /2012

5 2 Safety 2.1 Important safety notices $ $ Read these operating instructions carefully before use. $ $ Only connect the to a power supply that complies with the mains voltage specifications stated on the 's rating plate. $ $ Before carrying out any maintenance, cleaning or repair work, the power supply to the must be disconnected. $ $ Maintenance, cleaning and repair work must only be carried out by trained professionals. $ $ In the event of damage to the or if its function is impaired, the must not be used. Contact your dealer immediately. $ $ Note the maintenance instructions and intervals. $ $ Protect the from the influences of weather. $ $ Never use the outdoors. $ $ For your own safety and to ensure the long service life of the, you should only use original spare parts. $ $ The device must only be used in accordance with the instructions for correct use. 2.2 Instructions for correct use Area of use The has been built in accordance with the technological state of the art and in compliance with safety technology regulations. No liability will be accepted for any damaged caused by inappropriate use, misuse, incorrect connections or incorrect maintenance / repair by untrained personnel. Such cases will also invalidate all warranty clauses. The is used to deliver heating water in heating systems. The is fully pre-assembled and designed for installation on a wall. The is not intended to be used by persons (including children) with limited physical, sensory or mental capacities or a lack of knowledge and experience Environmental conditions relevant to safety The must not be assembled or operated outdoors. The components are not UV resistant. The installation location for the must be selected so that maintenance and repair work can be carried out when required. 06/2012 Version 2.0 Page 5

6 2.3 Observance of the operating instructions notice Read these operating instructions carefully before use. To ensure the device is operated safely, the instructions in this operating manual as well as regional regulations (e.g. health and safety regulations) that must be made available to the operator of the device must be complied with. 2.4 Residual risks and safety measures Electrical energy! danger Risk of death from electric shock. h Do not touch live cables or components with wet hands. h Be aware of health and safety regulations when handling electric current. Hot water! warning Risk of severe scalding. h When draining the, do not touch the hot water. h Allow the to cool down before carrying out any maintenance, cleaning or repair work. Hot surfaces! warning Risk of severe burning. h During operation, do not touch any pipes or components. h Allow the to cool down before carrying out any maintenance, cleaning or repair work. h Wear heat-resistant safety gloves when having to work on any hot components. caution Working on the device by inadequately trained personnel! Risk of injury and material damage. h Maintenance, cleaning and repair work must only be carried out by trained professionals. Page 6 Version /2012

7 3 Setup HK 8130/8180 with HK 8130/8180 without 3-Way-Mixer A B 3-Way-Mixer D C Fig. 1: Type overview 1 Ball valve with thermometer (return line) 4 3-Way-Mixer 2 Ball valve with thermometer (supply line) 5 Actuator 3 Circulation pump A Return input B Supply outlet C Supply input D Return outlet HK 8130 HK Fig. 2: Dimensions [mm] /2012 Version 2.0 Page 7

8 4 Assembly and commissioning 4.1 Safety Electrical Energy! hazard Mortal danger through electrical shock. h Do not touch the live cables or components with moist hands. h Follow the accident prevention regulations when dealing with electrical current. caution Hazard through material damages! The pump assembly is not protected against spraying and dripping water. h Install the pump assembly only in a dry location. caution Material damages through pressure shocks! Occurrence of pressure shocks caused by rapid opening of the gate valves. h Open the gate valves always slowly and in a controlled manner. note The assembly and commissioning of the pump assembly may be performed only by qualified professional technicians. Please follow the country-specific standards and directives when installing and commissioning the pump assembly! Do not make any changes to the components (e.g. pumps, valves etc.), supply and discharge lines, and/or safety equipments which may impair the operational safety of the pump assembly. Please ensure that the power supply to the pump assembly is always freely accessible. note Wear personal safety equipment during maintenance, cleaning and repair work. Seite 8 Version /2012

9 4.2 Assembly note Install the pump assembly in such a way that it is placed at eye level. Dismantle the front encasing of the pump assembly. Fig. 3: Dismantle encasing (represented in type 8130) Mark the drilling points for installing pump assembly Fig. 4: Drilling dimensions [mm] Drill the holes corresponding to the screw and anchor size. Place the anchor. Insert the pump assembly. Screw the screws into the anchor. Connect the front and return lines (system connections, See Fig. 1 on page 7). Check all the screw connections for firm position. 06/2012 Version 2.0 Page 9

10 4.3 Initial operation Requirement is completely installed. Connect power supply. Connect the power supply of the pump assembly. note The electrical installation of the pump assembly may be performed only by trained The pump assembly switches on automatically after connecting the power supply. Vent the heating equipment. note Switch off the circulation pump during the venting process. Thermometer handle settings A B C Fig. 5: Thermometer handle settings A B C Operational setting: check valve operational; ball valve open Empty: check valve open; ball valve ½ open (only in the supply run) Service setting: ball valve closed Seite 10 Version /2012

11 5 Maintenance 5.1 Safety Electrical Energy! hazard Mortal danger through electrical shock. h Do not touch the live cables or components with moist hands. h Follow the accident prevention regulations when dealing with electrical current. h Stop the power supply of the pump assembly before undertaking any maintenance, cleaning and repair works and secure it against being switched again. Hot water! warning Severe burns possible. h Let the pump assembly cool down before undertaking any maintenance, cleaning and repair works. h Do not touch the hot water when rinsing, filling and emptying the pump assembly. Hot surfaces! warning Severe burns possible. h Do not touch the pipes and components when doing maintenance, cleaning and repairs works. h Let the pump assembly cool down before undertaking any maintenance, cleaning and repair works. h Wear heat-resistant safety gloves when you need to work with hot components. 5.2 Recommended maintenance intervals Job Check gate and ball valves for smooth movement Watch out for any noise development in the pump Check the pump assembly for leakages (visual inspection) Check the 3-way mixer for proper operation Check the actuator for proper operation Annual Annual Annual Annual Annual Interval 06/2012 Version 2.0 Page 11

12 5.3 Maintenance works Dismantle the circulation pump Stop the power supply of the pump assembly and secure it against being switched on again. Electrical Energy! hazard Mortal danger through electrical shock. h Do not touch the live cables or components with moist hands. h Follow the accident prevention regulations when dealing with electrical current. h Stop the power supply of the pump assembly before undertaking any maintenance, cleaning and repair works and secure it against being switched on again. Dismantle the front encasing of the pump assembly (see Fig. 3 on page 9). Close the ball valves (multifunction armature, Pos. A) by rotating the thermometer handle (see Thermometer handle settings on page 10). One after another dismantle the lower insulation (Pos. B), the thermometer handles forward and return travel (Pos. A) as well as the upper insulation (Pos. C). A A C B Fig. 6: Dismantle insulations (represented in type 8130) Loosen the wiring of the circulation pump. Page 12 Version /2012

13 Loosen the nuts (Pos. A) and dismantle the circulation pump (Pos. B). Hot water! warning Severe burns possible. h Let the pump assembly cool down before undertaking any maintenance, cleaning and repair works. h Do not touch the hot water when emptying the pump assembly. B A Fig. 7: dismantle the circulation pump (represented in type 8130) Install the circulation pump Replace damaged or defective sealings if required. Insert the circulation pump and tighten the nuts (tightening torques see Technical data on page 17). Connect the wiring of the circulation pump. Slowly open the ball valves (multifunction armature, Pos. A, Fig. 6 on page 12) by rotating the thermometer handle (see Thermometer handle settings on page 10). Apply pressure gently to the circulation pump and vent the equipment if required. note Switch off the circulation pump during the venting process. 06/2012 Version 2.0 Page 13

14 Check the pump assembly for tightness. Reconnect the power supply of the pump assembly. Dismantle the thermometer handle. Install the inner insulations, the thermometer handle and the front encasing Dismantle the 3-way mixer Stop the power supply of the pump assembly and secure it against being switched on again. Electrical Energy! hazard Mortal danger through electrical shock. h Do not touch the live cables or components with moist hands. h Follow the accident prevention regulations when dealing with electrical current. h Stop the power supply of the pump assembly before undertaking any maintenance, cleaning and repair works and secure it against being switched on again. Dismantle the front encasing of the pump assembly (see Fig. 3 on page 9). Close the ball valves (multifunction armature, Pos. A) by rotating the thermometer handle (see Thermometer handle settings on page 10). Dismantle the lower insulation. Bring the boiler into the middle position with the help of manual adjustment of the mixer motor. Dismantle the mixer motor (Pos. B, the assembly/dismantling of the mixer motor should be taken from the respective manufacturer s manual). Dismantle the mixer (Pos. A) by loosening the swivel nuts. A B Fig. 8: 3-way mixer Page 14 Version /2012

15 5.3.4 Install the 3-way mixer Replace the sealings at the screw connections. Insert the 3-way mixer and tighten the nuts (tightening torques see Technical data on page 17). Install the mixer motor (Pos. B, Fig. 8 on page 14). $ $ The assembly/dismantling of the mixer motor should be taken from the respective manufacturer s manual. note Watch out for the correct insertion position when inserting the 3-way mixer. Slowly open the gate valves of the supply and return lines. Apply pressure to the heating equipment and vent it if required. note Switch off the recirculation pump during the venting process. Check the pump assembly for tightness. Reconnect the power supply of the pump assembly. Install the insulations and the front encasing Acutator 3-way mixer note The correct positioning of the bearing shaft must be checked when retrofitting the acutator. A Fig. 9: Settings boiler A Boiler 1 Boiler in position 1: mixer closed 2 Boiler in position 2: mixer open 06/2012 Version 2.0 Page 15

16 B Fig. 10: settings bypass lever B Bypass lever 3 Setting of the bypass lever (B): bypass closed 4 Setting of the bypass lever (B): bypass open (factory settings) Change the supply and return flow Fig. 11: change supply and return flow Page 16 Version /2012

17 6 Technical data Dimensions (W x H x D) Type 8130 Type 8180 Weight Type 8130 Type 8180 Energy supply Maximum operating pressure Maximum permissible operating temperature General 300 x 320 x 235 mm 300 x 370 x 240 mm 5-10,5 kg 5,5-12 kg see pump-/controller manual 10 bar 90 C (observe specification of pump) Circulation pump For technical data of circulation pumps, see respective pump manuals. Fittings Pipes Plastics Flat gaskets O-rings Materials Hot-pressed brass Ms58 (CW614N) Stainless steel pipe Impact resistant and temperature resistant AFM34 and EPDM elastomer EPDM elastomer Tightening torque for screw connections with Reinz AFM 34 gasket 3 / 4 " 35 Nm 1" 55 Nm 1 1 / 4 " 90 Nm 1 1 / 2 " 130 Nm 2" 190 Nm 06/2012 Version 2.0 Page 17

18 Characteristics HK DN 20/25 Overall Gesamtdruckverlust pressure drop HK 8130/8180 HK DN Pressure Druckabfall decline (mbar) Flow Durchflluss rate (L/h) Overall Gesamtdruckverlust pressure drop HKM 8130/8180 HKM DN 32 with mit Mischer mixer Kvs=18,0 HKM DN 25 with mit Mischer mixer Kvs=10,0 HKM DN 25 with mit Mischer mixer Kvs=8,0 HKM DN 25 with mit Mischer mixer Kvs=6,3 HKM DN 25 with mit Mischer mixer Kvs=4,0 HKM DN 25 with mit Mischer mixer Kvs=2, Pressure Druckabfall decline (mbar) Flow Durchflluss rate (L/h) Page 18 Version /2012

19 7 Decommissioning, recommissioning 7.1 Decommissioning Disconnect the energy supply to the pump assembly and ensure it cannot be switched back on. Electrical energy! danger Risk of death from electric shock. h Do not touch live cables or components with wet hands. h Be aware of health and safety regulations when handling electric current. h Disconnect the energy supply to the pump assembly and ensure it cannot be switched back on before carrying out any maintenance, cleaning or repair work. Remove the front cover on the pump assembly (see Fig. 3 on page 9). Close all shut-off cocks for the water connections. In the event of prolonged periods of non-use: Depressurise the pump assembly (for example by opening the venting screws). notice During the depressurisation process of the pump assembly, water can leak out. 7.2 Recommissioning Slowly open all of the shut-off cocks for the water connections (see Fig. 5 on page 11). Prime the pump assembly slowly with pressure and vent it if necessary. Restore the power supply to the pump assembly. Re-assemble the front cover on the pump assembly. 8 Dismantling Dismantling can be performed for two reasons: In order to reassemble the device elsewhere. In order to dispose of the device. 9 Disposal 9.1 Safety notice If the pump assembly is to be reassembled elsewhere, the dismantling process must be prepared properly. All installation and fastening parts must be carefully dismantled, labelled and, if necessary, packaged for transportation. This will ensure that, upon reassembly, all the parts can be correctly assigned and fitted back in the appropriate place. warning Incorrect disposal pollutes the environment and the groundwater! h When disposing of system parts and operating materials, the regulations and guidelines set down by the legislator of the respective country must be observed. 9.2 Disposal Separate the components of the pump assembly into recyclable materials, hazardous materials and operating materials. Dispose of the pump assembly components or recycle them. 06/2012 Version 2.0 Page 19

20 Art.-Nr.:

HKF 8180 Operating instructions

HKF 8180 Operating instructions Operating instructions EN Version 1.0en /Edition 05/2013 Contents 1 Important basic information... 3 1.1 Limitation of liability... 3 1.2 Operator's responsibilities... 3 1.3 Documentation... 3 1.3.1 Content

More information

Friwa Compact. Operating instructions EN

Friwa Compact. Operating instructions EN Operating instructions EN Version 1.1 / Edition 09/2013 Contents 1 Key background information... 3 1.1 Limitation of liability... 3 1.2 Responsibilities of the operator... 3 1.3 Documentation... 3 1.3.1

More information

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN PREMIUM KITCHEN MIXER TAP PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN 282471 GB/IE/NI Assembly, operating and safety instructions Page 5 B 15mm HG00476A HG00476B C 5 4 12

More information

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg DE LUXE Substation Introduction The HERZ DE LUXE Substation is a firmly mounted unit for providing hot water. In contrast to a hot water boiler which heats and then stores the water before it is being

More information

PJ130S High Pressure Cleaner

PJ130S High Pressure Cleaner PJ130S High Pressure Cleaner Operator Manual Original instructions WARNING: Do not use the machine without reading the instruction sheet. Item Description OVERVIEW 1. High pressure washer 2. On/off switch

More information

FSW300 Series Flow Switch

FSW300 Series Flow Switch . FSW300 Series Flow Switch - 2 - Series FSW300 Series FSW300 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.1.1 Reed contact - Switching of

More information

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015 ANLAGENBAU HEAT EXCHANGER Table of Contents 1.0 General Information 1.2 User Instructions 1.3 Proper Use 1.4 General Safety Rules 2.0 Design and Function 3.0 Installation 3.1 Setting up the Plate Heat

More information

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use 1 Safety instructions 1.1 Proper use Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN 100 Any improper use, intervention in the design and deviation from the design data automatically

More information

APW-VAP-150P High Pressure Cleaner Operator Manual

APW-VAP-150P High Pressure Cleaner Operator Manual APW-VAP-150P High Pressure Cleaner Operator Manual BEFORE OPERATING THIS APPLIANCE PLEASE READ THESE INSTRUCTIONS CAREFULLY Item Description OVERVIEW 1. High pressure washer 2. On/off switch 3. Water outlet

More information

Service package PDAD- -SP (en) Assembly instructions d [ ]

Service package PDAD- -SP (en) Assembly instructions d [ ] Service package PDAD- -SP-12000 (en) Assembly instructions 8068819 1701d [8068821] Original instructions Installation and commissioning are to be carried out only by qualified personnel in accordance with

More information

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH Zephyr 16 DC FAN WELCOME Thank you and congratulation for choosing an EcoAir DC Fan to help you improve the air quality within your home. Inside you will find many helpful tips on how to use and maintain

More information

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions Operating Instructions Accessory Units Melitta Cafina XT Series Melitta Professional Coffee Solutions Contents General... 4. Manufacturer information... 4.2 About these instructions... 4.3 Explanation

More information

Maintenance regulations Service intervals SCA

Maintenance regulations Service intervals SCA Page : 1 / 6 1. Service Intervals for the Coffee Machine Servicing must be carried out every 40 000 coffee servings or 12 months C = Check A = Components relevant to safety (see item 3) Nos. 2.1 2.23 =

More information

Nilfisk Model VHS255 Drum Top Vacuum

Nilfisk Model VHS255 Drum Top Vacuum Instructions/Spare Parts Manual Nilfisk Model VHS255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in classified (hazardous) environments, as serious injury could result. Under

More information

HOT WASHER MODEL NO: KING150

HOT WASHER MODEL NO: KING150 WARNING: Do not use the hot washer without reading this manual HOT WASHER MODEL NO: KING150 PART NO: 7320175 OPERATION & MAINTENANCE INSTRUCTIONS LS1215 INTRODUCTION Thank you for purchasing this CLARKE

More information

GRIND PRO DUAL OR DISC SANDER. Operator Manual

GRIND PRO DUAL OR DISC SANDER. Operator Manual GRIND PRO DUAL OR DISC SANDER Operator Manual 2 GRIND PRO DUAL OR DISC ORTHO-SANDER INTRODUCTION The Grind Pro Dual or Disc Sander is a compact, durable machine designed for fast, complete finishing work.

More information

Installation & Operating Guide

Installation & Operating Guide 5-036 HOT WATER TANK Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase

More information

Panel Fan Series Operators Manual (Galvanized and Polymer)

Panel Fan Series Operators Manual (Galvanized and Polymer) Panel Fan Series Operators Manual (Galvanized and Polymer) 52" Belt Drive, Galvanized Panel Fan with Three Wing Blade IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before

More information

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE

More information

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1 Safety instructions Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead

More information

Niles Steel Tank Hot Water Generator Installation and Operation Manual

Niles Steel Tank Hot Water Generator Installation and Operation Manual Niles Steel Tank Hot Water Generator Installation and Operation Manual Contents: Contents 1 Hazard definitions 1 1. General Information.... 2 Availability... 3 Optional Control Packages... 5 2. Installation....

More information

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1 Specifications Rated voltage (V) AC 110-120V or 220-240V / 50-60Hz Vacuum motor power consumption(w/hp) 1200 / 1.6 Exhaust water pump power consumption(w/hp 800 / 1.1 Exhaust water pump flow (GPH/LPH)

More information

DUST EXTRACTOR INSTRUCTION MANUAL. 550W (3/4 HP) INDUCTION MOTOR 1850W AUTOMATIC POWER OUTLET 65L COLLECTION BAG ø100mm X 2.

DUST EXTRACTOR INSTRUCTION MANUAL. 550W (3/4 HP) INDUCTION MOTOR 1850W AUTOMATIC POWER OUTLET 65L COLLECTION BAG ø100mm X 2. KNOW YOUR PRODUCT DUST EXTRACTOR 550W (3/4 HP) INDUCTION MOTOR 1850W AUTOMATIC POWER OUTLET 65L COLLECTION BAG ø100mm X 2.5M SUCTION HOSE INSTRUCTION MANUAL WARNING: Read all safety warnings and all instructions.

More information

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Installation instructions These appliances deliver water not exceeding 50 ºC in accordance with AS3498. 1. Overview

More information

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1 Safety instructions Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions Installation, Operating and Servicing Instructions Opus 700 Electric Pasta Boiler OE7701, OE7702 Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number:

More information

Operating instructions

Operating instructions Operating instructions for automatic detergent dispensing unit AWD 10 To avoid the risk of accidents en - AU, NZ or damage to the appliance, it is essential to read these operating instructions before

More information

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres EFX 600 aquamanta TM the experts in aquatic technology >600 Litres Coldwater Tropical Marine 4year guarantee Instruction Manual Important Safeguards This appliance is not intended for use by persons (including

More information

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer) PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer) Galvanized Panel Fan IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before attempting to assemble, install, operate

More information

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE - SOLARE TERMICO Installation and operating instructions Temperature difference controller 6 inputs, 3 outputs, integrated data logger for

More information

Roth fixed-value control set with high-efficiency pump

Roth fixed-value control set with high-efficiency pump Energy Systems Roth fixed-value control set with high-efficiency pump Assembly Instructions Living full of energy Contents General information Intended use 3 Benefits 3 Layout/Components 3 Installation/Electrical

More information

Domestic Hot Water Tank

Domestic Hot Water Tank Installation and Operating Manual Domestic Hot Water Tank WWKS 300 WWKS 500 EN For the professionals Read carefully before installation Table of Contents 1 Use............................. 3 2 Safety Instructions

More information

INSTALLATION INSTRUCTIONS USER GUIDE

INSTALLATION INSTRUCTIONS USER GUIDE INSTALLATION INSTRUCTIONS USER GUIDE Standard Rangehood HF60LX4 and HF60LW4 model NZ AU CONTENTS Safety and warnings 3 Installation instructions 5 Operating instructions 13 Cleaning and maintenance 14

More information

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance

More information

Qualcast 430W Grass Trimmer (Model: GT2826)

Qualcast 430W Grass Trimmer (Model: GT2826) Qualcast 430W Grass Trimmer (Model: GT2826) Instruction Manual After Sales Support UK/Ireland 0845 077 8888 Republic of Ireland 0124 77708 Web www.homebasespares.co.uk Important - Please read these instructions

More information

Hot Chocolate Dispenser

Hot Chocolate Dispenser Hot Chocolate Dispenser Instruction manual Model: CN219-A AU Telephone Helpline: 1300225960 Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation

More information

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................

More information

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control Australian Version Electronic Wall Control 1 Introduction The BR342 reverse cycle rooftop air-conditioner is designed for installation onto Recreational Vehicles (RV s) at the time of manufacture or as

More information

User and maintenance manual

User and maintenance manual GB User and maintenance manual IMPORTANT SAFETY INSTRUCTIONS These instructions shall also be available on website: docs.whirlpool.eu. YOUR SAFETY AND THAT OF OTHERS IS HIGHLY IMPORTANT. This manual and

More information

Model: 1100 Float-Controlled Condensate Trap, PN 25

Model: 1100 Float-Controlled Condensate Trap, PN 25 1 Safety instructions Model: 1100 Float-Controlled Condensate Trap, PN 25 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

Thermostatic Concealed Shower Valve

Thermostatic Concealed Shower Valve Thermostatic Concealed Shower Valve Product may differ from image. Please retain this booklet for future aftercare reference Component Breakdown - Three Handle Valve Component breakdown Two Handle Valve

More information

The Professional s Choice

The Professional s Choice SureFlow compact range: 1000-C & 1000-M Auto-Fill Catering Water Boiler Installation And User Instructions The Professional s Choice CONTENTS CONTENTS & INTRODUCTION 2 SAFETY & ENVIRONMENTAL INFORMATION

More information

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification Product Specification ~ Minimum Working Pressure 0.5 bar ~ Maximum Working Pressure 4.0 bar ~ Cold Water Supply Temp 4-20 c ~ Hot Water Supply Temp 55-85 c ~ Fixing Centres 150mm +/- 20mm ~ Outlet size

More information

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions. High-Pressure Washer BY02-VBP-WTH BY02-VBP-WTR CAUTION : Do not use this device before reading the instructions. 1 1. Safety Instructions The appliance has been designed solely for private use outdoors

More information

Instant Hot Water Dispenser Owner s Manual

Instant Hot Water Dispenser Owner s Manual Model Hot1 Instant Hot Water Dispenser Owner s Manual Installation, Care & Use Instalacion, cuidado & uso Installation, soin et utilisation WHAT YOU SHOULD KNOW BEFORE YOU BEGIN For your satisfaction and

More information

Traditional Rigid Riser With Eight Inch Rose

Traditional Rigid Riser With Eight Inch Rose Traditional Rigid Riser With Eight Inch Rose BS20007013035 This product should only be fitted by a qualified plumber to NVQ (National Vocational Qualification) or SNVQ (Scottish National Vocational Qualification)

More information

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions GRUNDFOS INSTRUCTIONS Sololift2 C-3 Installation and operating instructions English (US) English (US) Installation and operating instructions Original installation and operating instructions. CONTENTS

More information

pure indoor living HIGH PERFORMANCE desk fan MODEL: BSF002, ISF004 INSTRUCTION MANUAL

pure indoor living HIGH PERFORMANCE desk fan MODEL: BSF002, ISF004 INSTRUCTION MANUAL pure indoor living HIGH PERFORMANCE desk fan MODEL: BSF002, ISF004 INSTRUCTION MANUAL IMPORTANT SAFEGUARDS PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS. This appliance can be used by children

More information

Installation & Operators Manual. The Classeq Pass Through Range

Installation & Operators Manual. The Classeq Pass Through Range Installation & Operators Manual The Classeq Pass Through Range HYDRO 857 HYDRO 957 Service 0844 2245 245 service@classeq.co.uk Part number 902.0005 Revision E Jan 2012 Language English Spares 0844 2245

More information

Instruction Manual Hydraulic Crimping Tool

Instruction Manual Hydraulic Crimping Tool Instruction Manual Hydraulic Crimping Tool 902-480 Due to continuing improvements, actual product may differ slightly from the product described herein. Read this material before using this product. Failure

More information

TH100 Three in One Instant Hot Water Tap

TH100 Three in One Instant Hot Water Tap TH100 Three in One Instant Hot Water Tap Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu

More information

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them. K 1.100 Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. www.kaercher.com/register-and-win 59651430 (10/13) Contents General information..............

More information

AeroVent 3X Product Manual

AeroVent 3X Product Manual Product Manual AeroVent 3X TABLE OF CONTENTS Precautionary Warning... Page 1 Assembly... Page 2 Assembly Drawing... Page 3 Parts List... Page 3 Operation... Page 4 Maintenance... Page 5 Cobalt Point Replacement...

More information

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...

More information

JLBIHD624 60cm Cooker Hood

JLBIHD624 60cm Cooker Hood JLBIHD624 60cm Cooker Hood User guide 2 Cooker hood user guide Contents Contents 3 Introduction 4 Safety is important 4 In the box 4 Safety information 5 Important safety information 5 Warnings 5 Cautions

More information

Operating instructions DULCO flex DFDa Peristaltic Pump

Operating instructions DULCO flex DFDa Peristaltic Pump Operating instructions DULCO flex DFDa Peristaltic Pump A0381 Please carefully read these operating instructions before use! Do not discard! The operator shall be liable for any damage caused by installation

More information

Series 1140 and 1141 Temperature Regulators

Series 1140 and 1141 Temperature Regulators Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE

More information

Operating instructions Electric agitator RE80Ex. T-Dok-520-GB-Rev.5 Article no Translation of the original operating instructions

Operating instructions Electric agitator RE80Ex. T-Dok-520-GB-Rev.5 Article no Translation of the original operating instructions GB Operating instructions Electric agitator RE80Ex T-Dok-520-GB-Rev.5 Article no. 200-0332 Translation of the original operating instructions Thank you for selecting a Krautzberger product. This product

More information

Instructions For Use ENG. LED Magnifier Lamp

Instructions For Use ENG. LED Magnifier Lamp Instructions For Use ENG OPTICA 488 LED Magnifier Lamp ENG Table of Contents 1. For your safety...3 1.1 Designated use...3 1.2 Safety instructions...3 1.3 Warning levels...4 2. Mounting...4 2.1 Mounting

More information

User Instruction Manual

User Instruction Manual User Instruction Manual Export Electric Catering Urn Please read and keep these instructions These instructions cover the Burco 10, 20 and 30 litre electric catering urns for export SKU s 444441912, 444441913

More information

Manual Page 1 of 8. Manual. Laboratory autoclave

Manual Page 1 of 8. Manual. Laboratory autoclave Manual 17.11.2014 Page 1 of 8 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav

More information

150MM ELECTRIC EARTH BORER

150MM ELECTRIC EARTH BORER 150MM ELECTRIC EARTH BORER MODEL NO: CEA150 PART NO: 3400997 OPERATING & MAINTENANCE INSTRUCTIONS GC0915 INTRODUCTION Thank you for purchasing this CLARKE Electric Earth Borer designed for boring holes

More information

D O U B L E A U G E R M O R TA R M I X E R OWNER S MANUAL

D O U B L E A U G E R M O R TA R M I X E R OWNER S MANUAL D O U B L E A U G E R M O R TA R M I X E R OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT SWING LRSWING Installation Manual Split Type Wall Mounted Air Conditioner COOL RUN C SPEED TURBO ON/OFF FAN COOL HEAT SWING SWING Rinnai Systems Models System Indoor Outdoor HSNRQ25B HINRQ25B HONRQ25B

More information

DD VP-U. Operating instructions Mode d emploi Manual de instrucciones Manual de instruções. Printed: Doc-Nr: PUB / / 000 / 01

DD VP-U. Operating instructions Mode d emploi Manual de instrucciones Manual de instruções. Printed: Doc-Nr: PUB / / 000 / 01 DD VP-U Operating instructions Mode d emploi Manual de instrucciones Manual de instruções en fr es pt Printed: 08.07.2013 Doc-Nr: PUB / 5069625 / 000 / 01 1 1 2 3 4 5 + 9 6 8 7 This Product is Listed Ce

More information

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data Instruction manual Submersible sump pump Safety instructions Application Electrical connection Installation Maintenance Technical data U 3 K /2 U 3 KS /2 U 3 K spezial /2 U 3 KS spezial /2 U 5 K /0 U 5

More information

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50 -30 Installer manual Air/air heat pump -40/50 IHB GB 1516-1 331554 Table of Contents 1 Important information 2 5 Installation 7 Safety information 2 Model combinations 7 Read before starting the installation

More information

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET 1 INDEX 1 TECHNICAL DATA 2 TEMPERATURE ALTERNATIVES 3 PACK CONTENTS 4 PRE-INSTALLATION INFO 5-6 FAUCET INSTALLATION 7 ADJUSTING

More information

Installation & Operating Instructions

Installation & Operating Instructions 3WAY TAP Installation & Operating Instructions AQP-TAP-3S Three Way Tap AQP-TAP-3G Three Way Tap SYSTEM Congratulations on your purchase of the Filtered Water Sink Mixer 3 Way Tap AQUAPORT SELECT 3 STEP

More information

Electric Honey Extractor

Electric Honey Extractor Electric Honey Extractor Instruction Manual SKU: BEE-V004E Scan the QR code with your mobile device or follow the link for helpful videos and specifications related to this product. https://vivo-us.com/products/bee-v004e

More information

DR6000 UK_110 x /12/13 11:40 Page1

DR6000 UK_110 x /12/13 11:40 Page1 1800129621 DR6000 UK_110 x 154 02/12/13 11:40 Page1 1800129621-48/13 1800129621 DR6000 UK_110 x 154 02/12/13 11:40 Page2 I n s t r u c t i o n f o r u s e EN www.rowenta.com 1800129621 DR6000 UK_110 x

More information

User Instruction Manual

User Instruction Manual User Instruction Manual 4 & 6 Slot Toasters This covers the Burco 4 & 6 slot toasters TSSL14 & TSSL16 444440355 & 444440356 Red End Cap 4 slot 444440606 Red End Cap 6 slot 444440608 Cream End Cap 4 slot

More information

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W 594 59P0 Flow switch for liquids in piping DN 0 00. QE90 Contact load / switching capacity: Nominal pressure PN5 Manual setting of contact type (NO / NC) Housing IP 65 / safety class II Maintenance free

More information

100T Electric Shop Press

100T Electric Shop Press 100T Electric Shop Press Operation Manual 1 Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations

More information

SAFETY AND OPERATING MANUAL. Original Instructions 5.0

SAFETY AND OPERATING MANUAL. Original Instructions 5.0 SAFETY AND OPERATING MANUAL Original Instructions 5.0 Read all safety warnings and all instructions before use. Failure to follow the warnings and instructions may result in electric shock, fire and/or

More information

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 0772150/4 IM-P077-02 ST Issue 4 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning

More information

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm Safety instructions The washing machine is heavy - take care when lifting. Caution: frozen hoses may rip/burst. Do not install the washing machine in areas exposed to frost or outdoors. The washing machine

More information

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use GB122 Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C For trade use Please read thoroughly before attemting to diagnose fault 7217 4900 (03/2010) GB/IE List of contents

More information

UV Lamp and Quartz Sleeve Replacement/Maintenance

UV Lamp and Quartz Sleeve Replacement/Maintenance UV Lamp and Quartz Sleeve Replacement/Maintenance Models: Tap, Tap Plus, Home, Home Plus, Professional, Professional Plus (Excluding, D4, E4, F4, and Plus and Monitored versions) Overview UV Lamp replacement:

More information

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use GB122 7210 1300-12/2002 GB(EN) For trade use Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C Please read thoroughly before attempting to diagnose fault List of contents

More information

SuperKlean Washdown Products

SuperKlean Washdown Products DURAREEL DR8 & DR8S INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** GENERAL WARNINGS High pressure and hot

More information

Operating instructions DULCO flex DFDa Peristaltic Pump

Operating instructions DULCO flex DFDa Peristaltic Pump Operating instructions DULCO flex DFDa Peristaltic Pump EN A0381 Please carefully read these operating instructions before use. Do not discard. The operator shall be liable for any damage caused by installation

More information

HD Kompakt Service Manual

HD Kompakt Service Manual HD Kompakt Service Manual English 5.906-583.0 Rev. 00 (08/13) 1 1 Contents 1 Contents.................................................... 2 2 Preface.....................................................

More information

Detailed Cleaning Instructions

Detailed Cleaning Instructions NY Thermal Inc. Tel: (06) 67-6000 Toll Free: 1-800-688-27 Fax: 1-06-432-113 Web: www.ntiboilersl.com Email: info@ntiboilers.com Style Heat Exchanger occupants or, death. This boiler must be serviced by

More information

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285 Operating manual BlueMobil 60 Item no: Z-3285 Original operating manual Illustration shows item no Z-3285 Important Copyright It is essential that you read this manual thoroughly before the initial operation

More information

Installation & Operating Guide

Installation & Operating Guide HOT WATER DISPENSER Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase

More information

Low-voltage motors SIMOTICS GP, SD, DP Safety instructions for SH

Low-voltage motors SIMOTICS GP, SD, DP Safety instructions for SH Low-voltage motors SIMOTICS GP, SD, DP Readme You can find the associated operating instructions in the Internet: Low-voltage motors (https://support.industry.siemens.com/cs/ww/en/ps/13309/man) Technical

More information

2 IN 1 JUICER AND BLENDER

2 IN 1 JUICER AND BLENDER YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY 2 IN 1 JUICER AND BLENDER MODEL N19001 TECHNICAL DATA Description: Model: Rated Voltage: Frequency: Power consumption: 2 in 1 Juicer and Blender N19001

More information

STEAM BRUSH Model: E-6001A

STEAM BRUSH Model: E-6001A STEAM BRUSH Model: E-6001A Instruction Manual TECHNICAL SPECIFICATIONS Model Number EL-6001A Operating Voltage 220-240V Operating Frequency Power Consumption 50-60Hz 1000W PRODUCT OVERVIEW A. Base B. Flat

More information

STEAM WALLPAPER STRIPPER MODEL HTW5

STEAM WALLPAPER STRIPPER MODEL HTW5 STEAM WALLPAPER STRIPPER MODEL HTW5 From Serial Number 75154 (110 Volt North America only) OWNERS MANUAL & OPERATING INSTRUCTIONS 2016/11 Hiretech Part # 007717 WARNING For safe operation of this machine,

More information

Portable Ventilation Fans

Portable Ventilation Fans Portable Ventilation Fans Model Numbers: PV300, PV450 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE OPERATING INSTRUCTIONS Packaging Please DO NOT dispose of any packaging until you have

More information

100 Series Maxi Internal Filters

100 Series Maxi Internal Filters 100 Series Maxi Internal Filters Important Safeguards To guard against injury, basic safety precautions should be observed, including the following: 1. Read and follow all safety instructions and important

More information

55-Gallon Dispenser Package

55-Gallon Dispenser Package INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308 666 Rev. A Husky 715 55-Gallon Dispenser Package 100 psi (6.9 bar) Maximum

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FCB Pinnacle 4 Flavor Wide Body Units Thermostat Reset Upgrade Kit P/N 629088712 Release Date: January 23, 2006 Publication Number: 629088712INS Revision Date: March 24, 2014

More information

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278 Illustration shows item no Z-3278 Operating manual BlueMobil eco Item no: Z-3278 Original operating manual Important Copyright It is essential that you read this manual thoroughly before the initial operation

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 793-0 Fax +49 (0) 793-0 info@de.ebmpapst.com www.ebmpapst.com CONTENTS. SAFETY REGULATIONS AND NOTES. Levels of hazard warnings.

More information

Important Safeguards. Topic 2 SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY 3

Important Safeguards. Topic 2 SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY 3 User s Manual Index Topic Important safeguards 03 Safety features 05 Parts and accessories 05 Before first use 06 Operating instructions 06 Programme settings 08 Care and cleaning 09 Pressure canning guide

More information

USER MANUAL. ICON60H Version 00. Vertical Glass Hood

USER MANUAL. ICON60H Version 00. Vertical Glass Hood USER MANUAL ICON60H Version 00 Vertical Glass Hood [02] x 1 [01] x 1 [03] x 1 [04] x 1 [07] x 1 [05] x 1 [08] x 9 [06] x 1 [09] x 9 (4 x 30mm) [10] x 2 (3 x 10mm) Cooker hood Let's get started... These

More information

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL S-SCORT II Model 15006 SSCOR, INC. 11064 Randall Street Sun Valley, CA 91352 USA Telephone +1-818-504-4054 800-434-5211 Fax +1-818-504-6032 www.sscor.com Email:

More information