Certificate: _02 / 9 September 2014

Size: px
Start display at page:

Download "Certificate: _02 / 9 September 2014"

Transcription

1

2 : of 3 April 014 Initial certification: 1 February 010 Expiry date: 11 February 015 Publication: BAnz AT 5 August 014 B11, chapter I, no. 4.5 Approved application The tested AMS is suitable for use at combustion plants according to Directive 010/75/EU, chapter III, at waste incineration plants according to Directive 010/75/EU, chapter IV and other plants requiring official approval. The measured ranges have been selected considering the wide application range of the AMS. The suitability of the AMS for this application was assessed on the basis of a laboratory test and a sixmonth field test at a nitric acid plant. The AMS is approved for an ambient temperature range of +5 C to +40 C. Any potential user should ensure, in consultation with the manufacturer, that this AMS is suitable for the installation at which it will be installed. Basis of the certification This certification is based on: test report of 3 April 014 of Energie und Umwelt GmbH suitability announced by the German Federal Environment Agency (UBA) as the relevant body the ongoing surveillance of the product and the manufacturing process publication in the German Federal Gazette: BAnz AT 5 August 014 B11, chapter I, no. 4.5 UBA announcement of 17 July 014 qal1.de info@qal1.de page of 13

3 AMS designation: MCA 04 for N O, NO, H O, HCl, CO, NO, SO and O :, Markranstädt Field of application: For measurements at plants requiring official approval (e.g. Directive 010/75/EU on industrial emissions, chapters III and IV) Measuring ranges during the performance test: Components Certification ranges Supplementary ranges Unit H O Vol.-% HCl mg/m³ CO mg/m³ NO mg/m³ SO mg/m³ O Vol.-% N O mg/m³ NO mg/m³ Software version: MC3 Firmware V 1.83 Restrictions: 1. For SO in the measuring range 0-75 mg/m 3 the minimum requirements for the crosssensitivity of CH 4 concentrations > 30 mg/m 3 are not fulfilled.. The measuring system is not suitable for monitoring the component HCl at plants with NO - concentrations > 10 mg/m 3 and N O concentrations > 0 mg/m The component CO is not tested for suitability in accordance with EN Nevertheless, it must be used in the measuring system for the purpose of interference compensation and it shall be maintained as described in the manual. 4. Requirements with regard to the determination coefficient R² in accordance with EN were not satisfied for the component HCl during performance testing. Notes: 1. The measuring system uses wet sample gas.. The maintenance interval is three months. 3. Supplementary testing (transition to EN 1567) as regards Federal Environmental Agency notices of 8 July 010 (BAnz p. 597, chapter I no. 1.1) and of 1 February 013 (BAnz AT 5 March 013 B10, chapter V, notification 7). : Energie und Umwelt GmbH, Cologne Report-no.: of 3 April 014 qal1.de info@qal1.de page 3 of 13

4 Certified product This certificate applies to automated measurement systems conforming to the following description: The MCA 04 multi component gas analyser is a measuring system for the continuous measurement of gas components in waste gases. It can measure up to eight components quasi-simultaneously. The optical bench for measuring the infrared-active components consists of an infrared source with a chopper, a test cell, a rotating filter disk and a detector. For the measurement of the infrared-active components two different measuring principles are used: bi-frequency method (SO, H O, NO ) and gas filter correlation (CO, NO, HCl, N O) For the measurement of the oxygen content in the sample gas an extractive zirconium dioxide cell is used. The MCA 04 analyser system consists of a temperature-controlled, vented steel cabinet with partial pivoting frame and a clear door. The complete electrical equipment/electronics (electric feeding, power distribution, signal processing and SPS) as well as the gas treatment system are mounted on the mounting board and on further assembly rails. The tested AMS consists of the following single components: sampling probe SP 000 H with heated filter element heated sample gas line (length during supplementary testing: 15 m) analyser cabinet MCA 04 software MC3 Firmware V 1.83 General notes This certificate is based upon the equipment tested. The manufacturer is responsible for ensuring that on-going production complies with the requirements of the EN The manufacturer is required to maintain an approved quality management system controlling the manufacture of the certified product. Both the product and the quality management systems shall be subject to regular surveillance. If a product of the current production does not conform to the certified product, Energie und Umwelt GmbH must be notified at the address given on page 1. A certification mark with an ID-Number that is specific to the certified product is presented on page 1 of this certificate. This can be applied to the product or used in publicity material for the certified product. This document as well as the certification mark remains property of Energie und Umwelt GmbH. With revocation of the publication the certificate loses its validity. After the expiration of the certificate and on requests of the Energie und Umwelt GmbH this document shall be returned and the certificate mark must not be employed anymore. The relevant version of this certificate and its expiration is also accessible on the internet: qal1.de. qal1.de info@qal1.de page 4 of 13

5 Certification of MCA 04 for N O, NO, H O, HCl, CO, NO, SO and O is based on the documents listed below and the regular, continuous monitoring of the Quality Management System of the manufacturer: First performance test : 936/103173/A of 13 July 005 TÜV Immissionsschutz und Energiesysteme GmbH, Cologne Publication: BAnz. 9 October 005, no. 06, p UBA announcement of 5 July 005 Supplementary testing : 936/103173/B of 3. December 005 TÜV Immissionsschutz und Energiesysteme GmbH, Cologne Publication: BAnz. 8 April 006, no. 70, p. 654 UBA announcement of 1 February 006 Initial certification according to EN 1567* Certificate no : 1 February 010 Expiry date of the certificate: 11 February 015 : 936/111571/A of 8 October 009 Energie und Umwelt GmbH, Cologne Publication: BAnz. 1 February 010, no. 4, p. 554 UBA announcement of 5 January 010 Supplementary testing according to EN 1567* Certificate no _01: 8 July 010 Expiry date of the certificate: 11 February 015 : 936/111571/B of 5 March 009 Energie und Umwelt GmbH, Cologne Publication: BAnz. 8 July 010, no. 111, p. 597 UBA announcement of 1 July 010 Supplementary testing according to EN 1567 Certificate no _0: 19 August 014 Expiry date of the certificate: 11 February 015 : of 3 April 014 Energie und Umwelt GmbH, Cologne Publication: BAnz AT 5 August 014 B11, chapter I, no. 4.5 UBA announcement of 17 July 014 Notices Publication: BAnz AT 5 March 013 B10, chapter III, notice 7 (new enclosure) UBA announcement of 1 February 014 * Only the components N O and NO were tested and certified. ** Testing and certification for the components CO, NO, SO, NO, N O, HCl, H O and O. qal1.de info@qal1.de page 5 of 13

6 Serial number of units under test 150 / 15 / 18 / 116 / 355 / 368 / 155 / 154 gas filter correlation Measured component CO Certification range 0-75 mg/m³ Sum of positive CS at zero point 0.00 mg/m³ Sum of negative CS at zero point 0.00 mg/m³ Sum of postive CS at span point 0.30 mg/m³ Sum of negative CS at span point -.40 mg/m³ Maximum sum of cross-sensitivities -.40 mg/m³ Uncertainty of cross-sensitivity mg/m³ Standard deviation from paired measurements under field conditions * u D mg/m³ 0.18 (mg/m³)² Lack of fit u lof mg/m³ (mg/m³)² Zero drift from field test u d,z mg/m³ (mg/m³)² Span drift from field test u d,s mg/m³ (mg/m³)² Influence of ambient temperature at span u t mg/m³ (mg/m³)² Influence of supply voltage u v mg/m³ (mg/m³)² Cross-sensitivity (interference) u i mg/m³ 1.90 (mg/m³)² Influence of sample gas flow u p mg/m³ (mg/m³)² Uncertainty of reference material at 70% of certification range u rm mg/m³ (mg/m³)² 1.93 mg/m³ Total expanded uncertainty U = u c * k = u c * mg/m³ Relative total expanded uncertainty U in % of the ELV 50 mg/m³ 7.5 Requirement of 010/75/EU U in % of the ELV 50 mg/m³ 10.0 Requirement of EN U in % of the ELV 50 mg/m³ 7.5 qal1.de info@qal1.de page 6 of 13

7 Serial number of units under test 150 / 15 / 18 / 116 / 355 / 368 / 155 / 154 bi-frequency method Measured component H O Certification range 0-40 Vol.-% Sum of positive CS at zero point 0.00 Vol.-% Sum of negative CS at zero point 0.00 Vol.-% Sum of postive CS at span point 0.40 Vol.-% Sum of negative CS at span point 0.00 Vol.-% Maximum sum of cross-sensitivities 0.40 Vol.-% Uncertainty of cross-sensitivity 0.31 Vol.-% Repeatability standard deviation at set point * u r 0.19 Vol.-% (Vol.-%)² Lack of fit u lof 0.08 Vol.-% (Vol.-%)² Zero drift from field test u d,z Vol.-% (Vol.-%)² Span drift from field test u d,s Vol.-% 0.03 (Vol.-%)² Influence of ambient temperature at span u t 0.5 Vol.-% (Vol.-%)² Influence of supply voltage u v Vol.-% (Vol.-%)² Cross-sensitivity (interference) u i 0.31 Vol.-% (Vol.-%)² Influence of sample gas flow u p -0.6 Vol.-% (Vol.-%)² Uncertainty of reference material at 70% of certification range u rm 0.33 Vol.-% (Vol.-%)² 0.61 Vol.-% Total expanded uncertainty U = u c * k = u c * Vol.-% Relative total expanded uncertainty U in % of the range 40 Vol.-% 3.0 Requirement of 010/75/EU U in % of the range 40 Vol.-% 10.0 ** Requirement of EN U in % of the range 40 Vol.-% 7.5 ** The EU-directive 010/75/EU on industrial emissions provides no requirements for this component. The value used was 10 %. qal1.de info@qal1.de page 7 of 13

8 Serial number of units under test 150 / 15 / 18 / 116 / 355 / 368 / 155 / 154 gas filter correlation Measured component HCl Certification range 0-15 mg/m³ Sum of positive CS at zero point 0.4 mg/m³ Sum of negative CS at zero point mg/m³ Sum of postive CS at span point 0.46 mg/m³ Sum of negative CS at span point mg/m³ Maximum sum of cross-sensitivities mg/m³ Uncertainty of cross-sensitivity mg/m³ Standard deviation from paired measurements under field conditions * u D 0.39 mg/m³ (mg/m³)² Lack of fit u lof mg/m³ 0.08 (mg/m³)² Zero drift from field test u d,z mg/m³ 0.06 (mg/m³)² Span drift from field test u d,s 0.50 mg/m³ (mg/m³)² Influence of ambient temperature at span u t 0.89 mg/m³ (mg/m³)² Influence of supply voltage u v mg/m³ (mg/m³)² Cross-sensitivity (interference) u i mg/m³ (mg/m³)² Influence of sample gas flow u p mg/m³ (mg/m³)² Uncertainty of reference material at 70% of certification range u rm 0.11 mg/m³ (mg/m³)² 0.64 mg/m³ Total expanded uncertainty U = u c * k = u c * mg/m³ Relative total expanded uncertainty U in % of the ELV 10 mg/m³ 1.5 Requirement of 010/75/EU U in % of the ELV 10 mg/m³ 40.0 Requirement of EN U in % of the ELV 10 mg/m³ 30.0 qal1.de info@qal1.de page 8 of 13

9 Serial number of units under test 355 / 368 bi-frequency method Measured component N O Certification range 0-50 mg/m³ Sum of positive CS at zero point 0.00 mg/m³ Sum of negative CS at zero point mg/m³ Sum of postive CS at span point 1.40 mg/m³ Sum of negative CS at span point mg/m³ Maximum sum of cross-sensitivities mg/m³ Uncertainty of cross-sensitivity mg/m³ Standard deviation from paired measurements under field conditions * u D.746 mg/m³ (mg/m³)² Lack of fit u lof mg/m³ (mg/m³)² Zero drift from field test u d,z mg/m³ (mg/m³)² Span drift from field test u d,s mg/m³ (mg/m³)² Influence of ambient temperature at span u t mg/m³ (mg/m³)² Influence of supply voltage u v 0.76 mg/m³ (mg/m³)² Cross-sensitivity (interference) u i mg/m³ (mg/m³)² Influence of sample gas flow u p mg/m³ (mg/m³)² Uncertainty of reference material at 70% of certification range u rm mg/m³ (mg/m³)² 3.07 mg/m³ Total expanded uncertainty U = u c * k = u c * mg/m³ Relative total expanded uncertainty U in % of the range 50 mg/m³ 1.0 Requirement of 010/75/EU U in % of the range 50 mg/m³ 0.0 ** Requirement of EN U in % of the range 50 mg/m³ 15.0 ** The EU-directive 010/75/EU on industrial emissions provides no requirements for this component. The value used was 0 %. qal1.de info@qal1.de page 9 of 13

10 Serial number of units under test 150 / 15 / 18 / 116 / 355 / 368 / 155 / 154 gas filter correlation Measured component NO Certification range 0-00 mg/m³ Sum of positive CS at zero point 3.76 mg/m³ Sum of negative CS at zero point -6.6 mg/m³ Sum of postive CS at span point 4.70 mg/m³ Sum of negative CS at span point mg/m³ Maximum sum of cross-sensitivities mg/m³ Uncertainty of cross-sensitivity mg/m³ Standard deviation from paired measurements under field conditions * u D 1.95 mg/m³ (mg/m³)² Lack of fit u lof mg/m³ 0.10 (mg/m³)² Zero drift from field test u d,z mg/m³ (mg/m³)² Span drift from field test u d,s mg/m³ 1.93 (mg/m³)² Influence of ambient temperature at span u t 1.58 mg/m³ (mg/m³)² Influence of supply voltage u v mg/m³ 0.4 (mg/m³)² Cross-sensitivity (interference) u i mg/m³ (mg/m³)² Influence of sample gas flow u p mg/m³ (mg/m³)² Uncertainty of reference material at 70% of certification range u rm mg/m³.613 (mg/m³)² 5.71 mg/m³ Total expanded uncertainty U = u c * k = u c * mg/m³ Relative total expanded uncertainty U in % of the ELV 98 mg/m³ 11.4 Requirement of 010/75/EU U in % of the ELV 98 mg/m³ 0.0 Requirement of EN U in % of the ELV 98 mg/m³ 15.0 qal1.de info@qal1.de page 10 of 13

11 Serial number of units under test 355 / 368 bi-frequency method Measured component NO Certification range 0-50 mg/m³ Sum of positive CS at zero point 1.66 mg/m³ Sum of negative CS at zero point -0.1 mg/m³ Sum of postive CS at span point 1.75 mg/m³ Sum of negative CS at span point mg/m³ Maximum sum of cross-sensitivities 1.75 mg/m³ Uncertainty of cross-sensitivity mg/m³ Standard deviation from paired measurements under field conditions * u D mg/m³ (mg/m³)² Lack of fit u lof 0.50 mg/m³ 0.70 (mg/m³)² Zero drift from field test u d,z mg/m³ (mg/m³)² Span drift from field test u d,s mg/m³ (mg/m³)² Influence of ambient temperature at span u t 0.08 mg/m³ (mg/m³)² Influence of supply voltage u v 0.61 mg/m³ (mg/m³)² Cross-sensitivity (interference) u i mg/m³ 1.00 (mg/m³)² Influence of sample gas flow u p mg/m³ (mg/m³)² Uncertainty of reference material at 70% of certification range u rm mg/m³ (mg/m³)² 1.7 mg/m³ Total expanded uncertainty U = u c * k = u c * mg/m³ Relative total expanded uncertainty U in % of the ELV 0 mg/m³ 1.4 Requirement of 010/75/EU U in % of the ELV 0 mg/m³ 0.0 Requirement of EN U in % of the ELV 0 mg/m³ 15.0 qal1.de info@qal1.de page 11 of 13

12 Serial number of units under test 150 / 15 / 18 / 116 / 355 / 368 / 155 / 154 zirconium dioxide measurement Measured component O Certification range 0-5 Vol.-% Sum of positive CS at zero point 0.00 Vol.-% Sum of negative CS at zero point 0.00 Vol.-% Sum of postive CS at span point 0.00 Vol.-% Sum of negative CS at span point 0.00 Vol.-% Maximum sum of cross-sensitivities 0.00 Vol.-% Uncertainty of cross-sensitivity Vol.-% Standard deviation from paired measurements under field conditions * u D Vol.-% (Vol.-%)² Lack of fit u lof Vol.-% (Vol.-%)² Zero drift from field test u d,z Vol.-% (Vol.-%)² Span drift from field test u d,s Vol.-% (Vol.-%)² Influence of ambient temperature at span u t Vol.-% 0.00 (Vol.-%)² Influence of supply voltage u v Vol.-% (Vol.-%)² Cross-sensitivity (interference) u i Vol.-% (Vol.-%)² Influence of sample gas flow u p Vol.-% (Vol.-%)² Uncertainty of reference material at 70% of certification range u rm 0.0 Vol.-% (Vol.-%)² 0.9 Vol.-% Total expanded uncertainty U = u c * k = u c * Vol.-% Relative total expanded uncertainty U in % of the range 5 Vol.-%.3 Requirement of 010/75/EU U in % of the range 5 Vol.-% 10.0 ** Requirement of EN U in % of the range 5 Vol.-% 7.5 ** The EU-directive 010/75/EU on industrial emissions provides no requirements for this component. The value used was 10 %. qal1.de info@qal1.de page 1 of 13

13 Serial number of units under test 150 / 15 / 18 / 116 / 355 / 368 / 155 / 154 bi-frequency method Measured component SO Certification range 0-75 mg/m³ Sum of positive CS at zero point.93 mg/m³ Sum of negative CS at zero point 0.00 mg/m³ Sum of postive CS at span point 3.00 mg/m³ Sum of negative CS at span point -.60 mg/m³ Maximum sum of cross-sensitivities 3.00 mg/m³ Uncertainty of cross-sensitivity 1.73 mg/m³ Standard deviation from paired measurements under field conditions * u D mg/m³ (mg/m³)² Lack of fit u lof mg/m³ (mg/m³)² Zero drift from field test u d,z 0.80 mg/m³ 0.67 (mg/m³)² Span drift from field test u d,s mg/m³ (mg/m³)² Influence of ambient temperature at span u t mg/m³ 1.3 (mg/m³)² Influence of supply voltage u v mg/m³ 0.65 (mg/m³)² Cross-sensitivity (interference) u i 1.73 mg/m³ (mg/m³)² Influence of sample gas flow u p 0.16 mg/m³ (mg/m³)² Uncertainty of reference material at 70% of certification range u rm mg/m³ (mg/m³)².91 mg/m³ Total expanded uncertainty U = u c * k = u c * mg/m³ Relative total expanded uncertainty U in % of the ELV 50 mg/m³ 11.4 Requirement of 010/75/EU U in % of the ELV 50 mg/m³ 0.0 Requirement of EN U in % of the ELV 50 mg/m³ 15.0 qal1.de info@qal1.de page 13 of 13

Certificate: _01 / 29 April 2014

Certificate: _01 / 29 April 2014 Test report: 936/21212540/D of 08 October 2013 Initial certification: 05 March 2013 Expiry date: 04 March 2018 Publication: BAnz AT 01 April 2014 B12, chapter I, No. 2.2 Approved application The tested

More information

Certificate: / 9 September 2014

Certificate: / 9 September 2014 : of 3 April 014 Initial certification: 5 August 014 Expiry date: 4 August 019 Publication: BAnz AT 5 August 014 B11, chapter I, no. 5. Approved application The tested AMS is suitable for use at combustion

More information

Certificate: _01 / 2 February 2015

Certificate: _01 / 2 February 2015 Test report: 936/21210059/A of 21 October 2009 Initial certification: 12 February 2010 Certificate: renewal (previous certificate 0000025931 of 10 March 2010 valid until 11 February 2015) Expiry date:

More information

Certificate: / 9 February 2011

Certificate: / 9 February 2011 Test report: 936/21212470/A of 1 October 2010 First certification: 26 January 2011 Run of validity until: 25 January 2016 Publication BAnz. 26 January 2011, No. 14, p. 294, Chapter I No. 1.1 Approved application

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000050625 Certified AMS: Manufacturer: Test lnstitute: A02000-Fidas24 for TOC ABB Automation GmbH Stierstädter

More information

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 28 July 2016

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 28 July 2016 I Umwelt Bundes Amt @ For our Environment A TÜVRheinland Precisely Right. CERTIFICATE on Product Conformity {QAL 1) Number of Certificate: 0000001013_01 ------------------------------------------------------------------

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Ceriificate No.: 0000028729_02 Certified AMS: Manufacturer: Test lnstitute: GM700-2 for HF SICK AG Nimburger Str. 11 79276 Reute

More information

Certificate: / 29 April 2014

Certificate: / 29 April 2014 Test report: 936/21217455/A of 10 September 2013 Initial certification: 01 April 2014 Expiry date: 31 March 2019 Publication: BAnz AT 01 April 2014 B12, chapter I, No. 1.1 Approved application The tested

More information

Certificate: _01 / 22 March 2013

Certificate: _01 / 22 March 2013 Test report: 936/21219384/A of 27 September 2012 Initial certification: 20 July 2012 Expiry date: 19 July 2017 Publication: BAnz AT 05 March 2013 B10, chapter I, No. 1.6 Approved application The tested

More information

Certificate: _01 / 22 March 2013

Certificate: _01 / 22 March 2013 Test report: 936/21219384/B of 27 September 2012 Initial certification: 20 July 2012 Expiry date: 19 July 2017 Publication: BAnz AT 05 March 2013 B10, chapter I, No. 1.5 Approved application The tested

More information

Certificate: _01 / 20 August 2013

Certificate: _01 / 20 August 2013 Test report: 936/21218492/B of 22 January 2013 Initial certification: 05 March 2013 Expiry date: 04 March 2018 Publication: BAnz AT 23 July 2013 B4, chapter II, No. 2.2 Approved application The tested

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000028731 01 Certified AMS: Manufacturer: Test lnstitute: D-R 800 for dust DUFUG GmbH Kollaustraße 105 22453 Hamburg

More information

Certificate: _02 / 22 March 2013

Certificate: _02 / 22 March 2013 Test report: 936/21216334/D of 17 September 2012 Initial certification: 02 March 2012 Expiry date: 01 March 2017 Publication: BAnz AT 05 March 2013 B10, chapter II, No. 2.1 Approved application The tested

More information

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: ENDA-5000 with analysing module CMA-5800 for NOx. S0 2, CO, co2 and 02

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: ENDA-5000 with analysing module CMA-5800 for NOx. S0 2, CO, co2 and 02 Umwelt Bundes Amt @ For our Environment /;;!.. TÜVRheinland Precisely Right. CERTIFICATE on Product Conformity (QAL 1) Number of Certificate: 0000035010 Certified AMS: : Test Institute: with analysing

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland{ ' Precisely Föght CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000038496_01 AMs designation: Manufacturer: Test Laboratory: PCME QAL 181 fortotaldust PCME Ltd. 60 Edison Road

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland'ä` Procis Iy Ftight. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000032301_01 AMs designation: fornox, S02, CO, C02and 02 Manufacturer: Test Laboratory: HORIBA Europe GmbH

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000035015 03 Certified AMS: Manufacturer: Test lnstitute: MERCEM300Z for Hg SICK AG Rengol9shauser Str. 17 a 88662

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVF}heinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000059868 AMs designation: Manufacturer: Test Laboratory: FIDAMAT 6 MEASURING SYSTEM fortoc SIEMENS AG Östliche

More information

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1) Certificate No.: 0000036945_02 Certified AMS: Manufacturer: Test lnstitute: DUSTHUNTER SP100 for dust SICK Engineering GmbH Bergener

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) TüVF=hein and'] f Pracisely F±ight. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000053814 AMs designation: A02000-Magnos28 for 02 Manufacturer: Test Laboratory: ABB Automation GmbH Stierstädter

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate number: 0000001014_03 Certified AMS: Manufacturer: Test lnstitute: 4500 MKlll for dust Land lnstruments lnternational

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No. : 0000028749 01 Certified AMS: Manufacturer: Test lnstitute: D-R 290 for dust DUFLAG GmbH Kollaustraße 105 22453

More information

CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: _03. V-CEM5100 for waste gas velocity. TÜV Rheinland Energy GmbH

CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: _03. V-CEM5100 for waste gas velocity. TÜV Rheinland Energy GmbH ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000035006_03 Certified AMS: Manufacturer: V-CEM5100 for waste gas velocity CODEL lnternational Ltd. Station Road,

More information

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1) ATÜVRheinland Precisely F=ight. CERTIFICATE of Product Conformity (QAL1) Certificate No.: 0000036943 02 Certified AMS: Manufacturer: Test lnstitute: DUSTHUNTER SB100 for dust SICK Engineering GmbH Bergener

More information

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1) JÄ TÜVF=heinland`:.ä;' Preci ely Right. CERTIFICATE of Product Conformity (QAL1) Certificate No.: 0000038506 02 AMs designation: lvlanufacturer: Test Laboratory: Modell 6888Afor02 Rosemount l nc. 8200

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Ceriificate No.: 0000036942 01 Certified AMS: Manufacturer: Test lnstitute: DUSTHUNTER C200 for dust SICK Engineering GmbH Bergener

More information

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19July2017. Köln, 17 August2012

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19July2017. Köln, 17 August2012 Umwelt Bundes Amt For our Environment A TÜVRheinland Precisely Right. CERTIFICATE on Product Conformity (QAL 1} Number of Certificate: 0000036942 Certified AMS: Manufacturer: Test Institute: Dusthunter

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Cerlificate number: 0000051693_03 Certified AMS: Manufacturer: Test lnstitute: HM 1400 TRX for mercury DURAG GmbH Kollaustraße 105

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland`jR' Procis ly Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000053816 AMs designation: Manufacturer: Test Laboratory: U3600-QALl for dust Auburn systems LLC S Electronics

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland'S' Pretisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000037054_01 AMs designation: Manufacturer: Test Laboratory: EM-D 5100fordust HORIBA GmbH Kaplanstraße 5 3430

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely F}ight. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000053803 Certified AMS: Manufacturer: Test lnstitute: D-R 808 for dust DURAG GmbH Kollaustr.105 Hamburg German

More information

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02 Umwelt Bundes Amt For our Environment /;;!.. TÜVRheinland Precisely Right. CERTIFICATE on Product Conformity (QAL 1) Number of Certificate: 0000001014_02 Certified AMS: Manufacturer: Test Institute: 4500

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland'ä ' Prcciscly Ftight. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000056508_01 AMs designation: Manufacturer: Test Laboratory: LDS 6 7M86121 with cd 6 7M86122 sensorfor NH3

More information

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1) Certificate No.: 0000037051 01 Certified AMS: Manufacturer: Test lnstitute: GM32 ln-situ-gasanalysator model Cross Duct for NO and

More information

_03 / 28 July 2015

_03 / 28 July 2015 Test report: 936/21221789/B of 19 March 2013 Initial certification: 02 August 2010 Certificate: renewal (previous certificate 0000027277_02 of 20 August 2013 valid until 01 August 2015) Date of expiry:

More information

Certificate: _01 / 19 August 2011

Certificate: _01 / 19 August 2011 Test report: 936/21209919/A of 26 March 2010 First certification: 02 August 2010 Run of validity until: 01 August 2015 Publication BAnz. 28 July 2010, No 111, page 2598 Approved application The AMS is

More information

Certificate: / 29 April / /D1 of 07 July 2006 Addendum 936/ /C of 20 September 2013

Certificate: / 29 April / /D1 of 07 July 2006 Addendum 936/ /C of 20 September 2013 Test report: Initial certification: 01 April 2014 Date of expiry: 31 March 2019 Certificate: 936/21203248/D1 of 07 July 2006 Addendum 936/21221382/C of 20 September 2013 Publication: BAnz AT 01 April 2014

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland`E' Pnetisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 00000038503_02 AMs designation: Manufacturer: Test Laboratory: 300E/T300forco Teledyne Advanced pollution lnstrumentation

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No. : 0000027201 01 Certified AMS: Manufacturer: Test lnstitute: OPSIS SM 200 with pmio-pre-separator OPSIS AB Box 244

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland'E' Pnecis W Ftight. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000038504_02 AMs designation: Manufacturer: Test Laboratory: 400E/T400for03 Teledyne Advanced pollution lnstrumentation

More information

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1) JÄ TüVFtheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1) Certificate No.: 0000039320_01 AMsdesignation: Manufacturer: Test Laboratory: Modell49ifor03 Thermo Fisher scientific 27 Forge

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000053812 Certified AMS: Manufacturer: Test lnstitute: FDM 11 Standard (dust monitor) PCME Ltd. Clearview Building

More information

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02 Umwelt Bundes Amt For our Environment /;;;!. TÜVRheinland Precisely Right. CERTIFICATE about Product Conformity {QAL 1) Number of Certificate: 0000026912_02 Certified AMS: Manufacturer: Test Institute:

More information

Certificate: / 29 April 2014

Certificate: / 29 April 2014 Test report: 936/21209885/F of 20 September 2013 Initial certification: 01 April 2014 Date of expiry: 31 March 2019 Publication: BAnz AT 01 April 2014 B12, chapter IV, No. 6.3 Approved application The

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate number: 0000028733_01 Certified AMS: Manufacturer: SWAM 5a Dual Channel Monitor for PMio and PM2,5 FAl lnstruments s.r.l.

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland']B:' Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Ceriificate No.: 0000028733 02 AMs designation: Manufacturer: SWAM 5a Dual Channel Monitor, SWAM 5a Dual Channel Hourly Mode

More information

CONFIRMATION of Product Conformity (QAL1)

CONFIRMATION of Product Conformity (QAL1) CONFIRMATION of Product Conformity (QAL1) AMS designation: Manufacturer: Test Laboratory: Fidas 200 S, Fidas 200 and Fidas 200 E for suspended particulate matter PM 10 and PM 2,5 PALAS GmbH Greschbachstraße

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000053810 08 Certified AMS: : Test lnstitute: Set CEM CERT 7M81957 for CO, NO, S0, C0, N0, NOx and 0 Östliche

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the StackFlowMaster System Manufactured by: ABB Ltd Oldends Lane Stonehouse Gloucestershire GL10 3TA Has been assessed by Sira Certification Service

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the FIDAMAT 6 FID Analyser manufactured by: Siemens Production Automisation S.A.S. 1 Chemin de la Sandlach B.P. 189 F-67506 Haguenau Cedex France

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the V-CEM5100 Flow Monitor Manufactured by: Codel International Ltd, Station Road Bakewell Great Britain Has been assessed by Sira Certification Service

More information

PRODUCT CONFORMITY CERTIFICATE AR500 Open Path Monitor with ER120

PRODUCT CONFORMITY CERTIFICATE AR500 Open Path Monitor with ER120 RAP-266 PRODUCT CONFORMITY CERTIFICATE AR500 Open Path Monitor with ER120, MCERTS, Sira Certification Service, Kent, UK, 2 February, 14 June 2016 PRODUCT CONFORMITY CERTIFICATE This is to certify that

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the D-R 290 Opacity and Dust Concentration Monitor manufactured by: DURAG GmbH Kollaustraße 105 22453 Hamburg Germany has been assessed by Sira Certification

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the AR500 Open Path Monitor Manufactured by: Opsis AB PO Box 244 5-244 02 Furulund Sweden Has been assessed by Sira Certification Service And for

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the AMESA D Isokinetic Dioxin Sampling System Manufactured by: Environnement S.A. Deutschland Benzstraße 11 61352 Bad Homburg Germany has been assessed

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the 3000HM Flame Ionisation Detector 3010 & 3030 Portable Flame Ionisation Detector manufactured by: Signal Group Ltd 12 Doman Road Camberley Surrey,

More information

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) PART 1 - GENERAL A. RELATED DOCUMENTS SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) Federal, State, and local requirements as applicable. Attached Permit Attached drawings B. SUMMARY 1. Provide

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 16429 March 2013 ICS 13.040.40 English Version Stationary source emissions - Sampling and determination of hydrogen chloride

More information

International comparison of validation methods for dust concentration measurement

International comparison of validation methods for dust concentration measurement International comparison of validation methods for dust concentration measurement Validation of dust monitors can be divided into 2 steps: 1. Validation of a generic dust monitor as an instrument (Type

More information

Complete Gas Analysis

Complete Gas Analysis Complete Gas Analysis A complete range of gas analysers, systems and accessories for emissions, air quality, research and process monitoring. The Signal Group, incorporating the gas analysis business of

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the GC 866 PID airtoxic (Model A73022) manufactured by: Chromatotec / airmotec 15, Rue d Artiguelongue Saint -Antoine 33240 Val de Virvée France has

More information

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring. Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working

More information

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986 Ministry of Environment & Forests, New Delhi Central Pollution Control Board, Delhi Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986 Surveillance

More information

portable gas analyser

portable gas analyser www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.

More information

CO2 Carbon Dioxide Sensor

CO2 Carbon Dioxide Sensor Environmental Devices Corporation Technical Data Sheet P/N HS-C02-6000 CO2 Carbon Dioxide CO2 Carbon Dioxide Sensor DESCRIPTION Patent Numbers Great Britain GB 2 401 432 & GB 2 403 291 Europe EP 1544603

More information

continuous emissions monitoring Combustion & Environmental Monitoring

continuous emissions monitoring Combustion & Environmental Monitoring continuous emissions monitoring Combustion & Environmental Monitoring Advanced CEM technology for accurate measurement and high reliability - to meet today s regulatory requirements and ready for future

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 12039 First edition 2001-06-15 Stationary source emissions Determination of carbon monoxide, carbon dioxide and oxygen Performance characteristics and calibration of automated

More information

ALTAIR 5X Multigas Detector Product Specification

ALTAIR 5X Multigas Detector Product Specification ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display

More information

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME Aspetti gestionali e verifiche periodiche (norma UNI EN 14181:2015) Walter Battaglia - Alessandro Migatta - Sandro

More information

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER Low pressure with PI-control-mode Manufacturer: Phone: Fax: E-Mail: Website: Issue: Doc.-no.: Arthur Grillo GmbH Am Sandbach

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK SIRA Certification Service Accredited to ISO/IEC 17065:2012 to provide product conformity Unit 6 Hawarden Industrial Park Hawarden Deeside

More information

HARMONISATION STATUS OF SELECTED ELECTRICAL AND NON-ELECTRICAL Ex STANDARDS MARCH 2018

HARMONISATION STATUS OF SELECTED ELECTRICAL AND NON-ELECTRICAL Ex STANDARDS MARCH 2018 Harmonisation status of selected electrical and non-electrical ex standards BAS-PS-010 - Issue 1 - March 2018 P. 1 HARMONISATION STATUS OF SELECTED ELECTRICAL AND NON-ELECTRICAL Ex STANDARDS MARCH 2018

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US. Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 63A Issue date 16 th June 2015 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44 (0)1244

More information

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US. Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 072A Issue date 23 rd March 2018 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44

More information

LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA)

LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA) LET S PLAY IT SAFE PREVENTIVE EXPLOSION PROTECTION AND AUTOMATION M ONI TOR CO NTR OL PR OTEC T robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA) Scan QR-Code

More information

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF 2015 SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF FINAL APPROVAL REVISION #: 0 ISSUE DATE: December 4, 2015 PAGE: 1 of 13 This Methods

More information

MultiGAS Monitoring System Hot/Wet IR Analyzer Technology. Clean Air Systems

MultiGAS Monitoring System Hot/Wet IR Analyzer Technology. Clean Air Systems MultiGAS Monitoring System Hot/Wet IR Analyzer Technology Clean Air Systems Tyco MultiGAS Monitoring System Continuous Emissions Monitoring (CEMS) Environmental Compliance Monitoring Process Gas Analysis

More information

Restek s Electronic Leak Detector

Restek s Electronic Leak Detector Restek s Electronic Leak Detector (cat.# 22839) Instruction Manual 2008 Restek Corporation No part of this manual may be reproduced in any form or by any means without the prior agreement or permission

More information

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca. Monitoring Parameter: Methane and Non-Methane Hydrocarbons Revision No: Draft Revision Date: 09 April, 2018 Title: Standard Operating Procedure for the Non-Continuous Measurement of Ambient Methane and

More information

Stand Alone DYNAGARD SP Operation Manual

Stand Alone DYNAGARD SP Operation Manual Stand Alone DYNAGARD SP Operation Manual Contents Page General Description 1 Detection Principle 1 For Your Safety 1 Design 2 Mounting 2 Mounting Position of DYNAGARD SP 2 Installation of Electrical Connections

More information

OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p. 136.

OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p. 136. 2 This document reflects the opinion of the European Commission and does not provide a legally binding interpretation of the regulations. Only the European Court of Law can provide a legally binding interpretation

More information

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following

More information

User Manual. GPD 3000 e. gas detector

User Manual. GPD 3000 e. gas detector User Manual GPD 3000 e gas detector Table of contents Application...3 Unit ppm, Vol.%...4 Operation elements GDP 3000 e...5 Gas sensor...6 Important Information off sensor!...6 Measurement range...7 Turning

More information

Understanding total measurement uncertainty in power meters and detectors

Understanding total measurement uncertainty in power meters and detectors Understanding total measurement uncertainty in power meters and detectors Jay Jeong, MKS Instruments. Inc. INTRODUCTION It is important that users of calibrated power meters and detectors understand and

More information

2. SCOPE. OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p OJ L 239, , p. 162.

2. SCOPE. OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p OJ L 239, , p. 162. 2 Table of Contents 1. Purpose of the guidelines and disclaimer... 4 1.1. The Regulations... 4 2. Scope... 4 2.1. Space Heaters and Combination Heaters... 5 2.2. Water Heaters... 5 3. Product environmental

More information

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now

More information

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ] ULTIMA XL/XT Series Gas Monitors [ Ultimate Features Extreme Design ] Cost effective fixed installation gas monitors with HART Field Communications Protocol. Single-sensor units use catalytic, electrochemical

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

PREMIER PLATINUM INFRARED GAS SENSOR

PREMIER PLATINUM INFRARED GAS SENSOR PREMIER PLATINUM INFRARED GAS SENSOR LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0150

More information

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol. IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol. FEATURES Two active gas channels for simultaneous detection of carbon dioxide and methane (or other hydrocarbons)

More information

Survey of the Burning Behaviour of the Refrigerant HFO-1234yf Brief Report

Survey of the Burning Behaviour of the Refrigerant HFO-1234yf Brief Report D M T G m b H & C o. K G B u i l d i n g S a f e t y Expert Body for Fire Protection Tremoniastraße 13 44137 Dortmund GERMANY Phone +49 231-5333-0 Fax +49 231-5333-299 Emaill: gs@dmt.de http://www.dmt.de

More information

Shipboard incinerators with capacities up to 4000 kw

Shipboard incinerators with capacities up to 4000 kw STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for Marine Equipment Directive (MED) No. 431.90 - MED A.1/2.7 Shipboard incinerators with capacities up to 4000 kw JANUARY

More information

SENSOR O2 O2-A

SENSOR O2 O2-A Item Inquiry Vian code Description QNY Manufacturer 1 7 10359 disposable O sensor SPXCDXSO1SS senspoint XCD 6 honeywell 104 136540 Sensor Gas,Gasmonitor 0-5 No:09737 1 Bieler+Lang 1 104 136543 SENSOR O

More information

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer. The Process TDLS Solution New Features TDLS 200 Tunable Diode Laser Spectroscopy (TDLS) Analyzer Bulletin 11Y01B01-01E-A www.yokogawa.com/an/index.htm The first Tunable Diode Laser analyzer Innovative

More information

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control The new generation of Multi-Gas measurement Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control Today our environment is more and more contaminated by critical

More information

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual Read instructions carefully before operating this device. ❶ This device is not to be used for Human Life Support applications. ❷ To avoid possible

More information

Mercury Vapor Monitor VM-3000

Mercury Vapor Monitor VM-3000 Member of the envea Group Mercury Vapor Monitor VM-3000 Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption (CVAAS)

More information

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts TOCSIN 750 SERIES SAFE AREA S -Wire Addressable Systems Addressable Interface to Controller. Network up to 3 Annunciators or other Addressable Devices per Highway. -Wire Addressable Core Cable Unscreened

More information

SEC Signature Process Gas Analyzer

SEC Signature Process Gas Analyzer SEC Signature Process Gas Analyzer Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 email sensor@minn.net

More information