1 Journeyman and Master Common Exam 2 1 The grounding terminal of a grounding-type receptacle installed in a metal box shall be? A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod 2 A #10 AWG Copper equipment grounding conductor can be used for branch circuits rated up to? A. 30A B. 40A C. 50A D. 60A 3 A #8 AWG copper grounding electrode conductor for a 100A 120/240V residential service is attached to a metal water pipe. Which statement below best describes its code requirement? A. Not permitted B. Must be enclosed in a raceway or armored cable C. Must only be connected to a ground rod D. None of the above 4 The aluminum grounding electrode required for an 800A service consisting of 3 sets of 400 kcmil RHW Aluminum conductors in parallel is? A. 1/0 Al B. 2/0 Al C. 3/0 Al D. 4/0 Al
2 5 A grounding electrode connection is required at a separate building or structure under which of the following conditions? A. More than one branch circuit B. Contains equipment requiring grounding C. Equipment grounding conductor is ran with the feeder D. All the above 6 A ground rod must be a minimum of in length? A. 6 feet B. 8 feet C. 10 feet D. 12 feet 7 The building steel of a metal frame building is considered a grounding electrode when? A. 8 feet of a single metal structure is in direct contact with earth B. It is bonded to an underground metal water pipe C. Connected to 20 of rebar enclosed in 2 or more concrete D. The building is bolted to a concrete slab 8 Which of the following is not an approved grounding electrode? A. A ten foot length of buried copper water pipe B. 8 x 5/8 iron ground rod C. 8 x 5/8 stainless steel rod D. 10 #4 AWG bare copper wire in concrete footer
3 9 Flexible metal conduit installed where flexibility is not a requirement shall be permitted for grounding purposes if? A. The length does not exceed 6 feet B. The circuit is rated 20A or less C. It is terminated in listed grounding fittings D. All of these 10 What is the minimum size copper equipment ground conductor permitted to ground 400A service equipment? A. #8 AWG B. #6 AWG C. #3 AWG D. #1/0 AWG 11 A raceway is installed below grade in sand. The interior of the raceway is considered a? A. Dry location B. Wet location C. Moist location D. Damp location 12 A 20A 120V UF, GFCI protected cable circuit is buried from a dwelling to a detached building. The minimum burial depth of the cable is? A. 6 inches B. 12 inches C. 18 inches D. 24 inches
4 13 Cables are installed exposed or concealed under metal corrugated sheet roof decking. What is the minimum allowed distance between the cable or conduit to the nearest surface of the roof decking? A. 1 1/8 B. 1 ¼ C. 1 3/8 D. 1 ½ 14 The minimum length of free conductor required by code to be left in boxes for splicing is? A. 3 B. 4 C. 5 D The minimum burial depth of a 15A 125V GFCI protected UF cable run to a lamppost without passing underneath a driveway is? A. 6 inches B. 12 inches C. 18 inches D. 24 inches
5 16 When supporting Romex (NM cable) boring through wooden framing members such as joists, rafters, or studs, how close to the nearest edge of these structures may it be installed? A. 1 ¼ B. 1 1/8 C. 1 3/8 D. 1 ½ 17 A vertical run of 4 inch rigid conduit is installed to a height of 250 ft. How many conductor supports are needed for the 500kcmil THHN copper conductors? A. None B. 3 C. 4 D Raceways installed underground are considered to be in? A. Damp locations B. Wet locations C. Dry locations D. Moist locations 19 There are 10 current-carrying conductors in a 1 IMC conduit. By what per cent of the allowable ampacity of Table be reduced? A. 50% B. 60% C. 70% D. 80%
6 20 What is the ampacity of four 4/0 AWG THHN copper current-carrying conductors in a raceway installed in an ambient temperature of 45 C? A A B A C A D A 21 Conductors of size and larger shall be permitted to be run in parallel? A. #10 AWG B. 500kcmil C. 1/0 D. 2/0 22 Wall mounted boxes for luminaires (light fixtures) must be designed to support a minimum weight of? A. 6 lbs B. 10 lbs C. 25 lbs D. 50 lbs 23 The computed load for a 120/240V single phase dwelling service is 185 amps. What is the minimum size 75 C Aluminum service entrance conductor permitted by the code? A. 2/0 B. 3/0 C. 4/0 D. 250kcmil
7 24 A straight-pull junction box will be installed in a 4 conduit run to splice three 350kcmil 208V conductors. What is the required minimum length of this junction box? A. 48 B. 32 C. 24 D Armored cables are to be secured within of every outlet box and junction box? A. 6 B. 8 C. 12 D All bends in armored cable must be made so that the inner edge of any bend shall not be less than times the diameter of the AC cable? A. 5 B. 4 C. 3 D. 2
8 27 When AC cable is installed in thermal insulation its conductors must be rated at a minimum of? A. 60 C B. 75 C C. 90 C D. 30 C 28 In unfinished basements and crawl spaces Non-metallic sheathed (NM) cable sheath shall extend into each box a minimum of? A. 1 inch B. ½ inch C. ¼ inch D. 6 inches 29 NM cable must be supported----? A. Every 4 ½ B. Every 4 C. Every 4 D. Every 4 ½ 30 When passing through a floor NMC must be protected for a distance of above the floor where it emerges? A. 4 B. 6 C. 8 D. 10
9 31 NMC must be secured within of a metal box? A. 6 inches B. 8 inches C. 10 inches D. 12 inches 32 The taper of a cutting die for field threading rigid conduit is? A. ½ taper per foot B. 5/8 taper per foot C. ¾ taper per foot D. Not tapered at all 33 In general rigid conduit must be supported within inches of every box, junction box, Panel or any other termination point? A. 12 B. 60 C. 36 D Flexible metal conduit shall not be used? A. In wet locations B. For motor leads C. Concealed inside walls D. Concealed inside attics
10 35 How many #10 AWG THHN conductors are allowed in a ¾ EMT conduit? A. 5 B. 10 C. 15 D A flexible cord connection is made directly to the load of a busway plug-in device. The maximum length of the cord to the tension take-up device is feet? A. 3 B. 4 C. 5 D Horizontal installations of non-metallic wireways shall be supported at distances not exceeding feet unless otherwise listed for other support intervals? A. 1 B. 2 C. 3 D Which of the following is not normally acceptable use for flexible cords? A. Pendants B. Elevator cables C. Portable lamps D. Attached to building surface
11 39 The identification of the grounded conductor in a flexible cord shall be permitted to be? A. Any color braid with contrasting tracer B. Black color conductor C. A blue braid D. Green insulation 40 Fixture wires shall not be smaller than? A. #18 AWG Cu B. #16 AWG Cu C. #14 AWG Cu D. #12 AWG Cu 41 All switches and circuit breakers used as switches shall be located so that the center of the operating handle is not more than above the floor? A. 6 feet B. 6 ½ feet C. 6feet 7 inches D. 6 feet 8 inches 42 Tamper resistant receptacles are not required in which rooms? A. Kitchens B. Laundries C. Basements D. They are required in all rooms
12 43 Porcelain pull chain fixtures are allowed in clothes closets. A. True B. False 44. A fixture that weighs more than 6 pounds shall not be supported by the screw shell of a lamp holder. A. True B. False 45 In a dwelling which of the following built-in appliances can be cord and plug connected if the cord is not readily accessible? A. Dishwasher B. Garbage disposal C. Trash compactor D. None of the above 46 Electric drinking fountains must be protected by? A. A dedicated 20A circuit B. AFCI breaker C. GFCI breaker or outlet D. A single receptacle 47 Bonding of metal parts in a swimming pool shall be made by? A. #8 AWG solid, bare or insulated copper B. #8 AWG stranded insulated copper C. #6 AWG bare copper D. #6 stranded copper insulated
13 48 The #8 AWG solid copper bonding conductor for a swimming pool is not required by the code to be connected to? A. Main service panel B. Metal ductwork 12 or higher above pool C. Metal fence 5 from inside edge of the pool D. Deck reinforcing metal 49 The metal bands used to secure wooden staves of a hot tub are not required to be bonded. A. True B. False 50 The minimum height of a community antenna system coaxial cable (CATV) above a wading pool is? A. 8 B. 10 C. 12 D. 14
14 Answers to Common Questions for the Journeyman and Master Exam 2 1 B 26 A 2 D 27 C 3 B 28 C 4 A 29 D 5 D 30 B 6 B 31 D 7 C 32 C 8 D 33 C 9 D 34 A 10 C 35 B 11 B 36 D 12 B 37 C 13 D 38 D 14 D 39 A 15 B 40 A 16 A 41 C 17 D 42 D 18 B 43 B 19 A 44 A 20 C 45 D 21 C 46 C 22 A 47 A 23 C 48 A 24 C 49 A 25 C 50 B
ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)
Cheboygan County Department of Building Safety 870 South Main Street P.O. Box 70 Cheboygan, Michigan 49721 TX: (231) 627-8813 FX: (231) 627-8454 www.cheboygancounty.net Service Entrance ONE- AND TWO-FAMILY
More information2009 ELECTRICAL CODE REQUIREMENTS
2009 ELECTRICAL CODE REQUIREMENTS ANTRIM COUNTY BUILDING DEPARTMENT PO BOX 188 205 CAYUGA STREET BELLAIRE, MI 49615 (231) 533-8373 FAX (231) 533-6041 Inspection Request Line (231) 533-3510 Electrical requirements
More informationAPPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL
This Appendix (2000 IRC Appendix-L) is produced, copyrighted, and maintained by the National Fire Protection Association Association, all rights reserved. Use of this Appendix is pursuant to license with
More informationTABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51
TABLE OF CONTENTS About This Textbook...xi How to Use the National Electrical Code... 1 Article 90 Introduction to the National Electrical Code... 7 90.1 Purpose of the NEC... 7 90.2 Scope of the NEC...
More information2011 and 2014 National Electrical Code Changes Residential Only
2011 and 2014 National Electrical Code Changes Residential Only Sponsored By: and.net Instructor: Fritz Gunther, Chief Electrical Inspector 585-436-4460 www.nyeia.com NEW YORK ELECTRICAL INSPECTION AGENCY
More informationRESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS
RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS Key Questions for Residential Inspections 1. What wiring methods will be used, and are the wiring methods suitable for the conditions? 2. Will multiwire branch
More informationCHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017
CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017 The City of Portsmouth adopts the State Building Code, which adopts by reference The National Electrical Code, 2017(NEC), as Chapter 15, Part IV, of the
More informationBuilding Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS
BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used
More informationTABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19
TABLE OF CONTENTS About This Textbook...xi How to Use the National Electrical Code... 1 Article 90 Introduction to the National Electrical Code... 7 90.1 Purpose of the NEC... 7 90.2 Scope of the NEC...
More informationRocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004
Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004 1. A 2 PVC conduit was installed in the ground prior to setting a factory manufactured home on the foundation. The required service
More informationChapter 1 General... 5
About This Textbook...xi About the National Electrical Code...xv About the Authors and Illustrator...xix About the Team...xxi Article 90 Introduction to the National Electrical Code... 1 90.1 Purpose of
More information2009 WESTERN SECTION CODE PANEL QUESTIONS
2009 WESTERN SECTION CODE PANEL QUESTIONS 1. The local inspector red-tagged the temporary wiring for a new store of type III construction because he said Romex wasn t allowed to be run in the open according
More informationSpring Test 6 due 04/26/2013
Spring Test 6 due 04/26/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. The article that covers TV wiring installations in residences
More informationSMALL HOMES COUNCIL - BUILDING RESEARCH COU CIL CIRCULAR SERIES INDEX G4 2 NUMBER ELECTRICAL WIRING
CIRCULAR SERIES INDEX G4 2 NUMBER ELECTRICAL WIRING ISSUED BY THE SMALL HOMES COUNCIL - BUILDING RESEARCH COU CIL COPYRIGHT@ 1964, 1977 BY THE BOARD OF TRUSTEES OF THE UNIVERSITY OF ILLINOIS. All rights
More information2017 NEC Presented by: Russ LeBlanc
2017 NEC Presented by: Russ LeBlanc 1. 90.2(A)-installation and removal 2. 90.3-code layout 3. 100-readily accessible 4. 100-field evaluation body (FEB) 5. 100-field labeled 6. 100-receptacle 7. 100-structure
More informationUniversity of Illinois at Urbana-Champaign Small Homes Council-Building Research Council COUNCIL NOTES G4.2 ELECTRICAL WIRING
University of Illinois at Urbana-Champaign Small Homes Council-Building Research Council COUNCIL NOTES G4.2 ELECTRICAL WIRING This circular is intended to be used as a guide in planning the electrical
More informationDistrict 1. 1 Tony Tadysak Craig Mulder
STATE OF WISCONSIN Department of Safety and Professional Services 1400 E Washington Ave. Madison WI 53703 Web: dsps.wi.gov Governor Scott Walker Secretary Dave Ross Electrical Program Web: Electrical Program
More informationResidential Wiring According to 2011 NEC (Homestudy)
Residential Wiring According to 2011 NEC (Homestudy) Utah Electrical License This course will cover the requirements in the 2011 NEC for installing electrical systems in dwelling units. Code sections for
More informationSECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35
SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1 Overview of Low-Voltage and Power-Limited Systems...3 Chapter 4 Equipment for General Use...3 Chapter 5 Special Occupancies...3 Chapter 6 Special Equipment...4
More informationResidential Wiring (2014 NEC) (Homestudy)
Residential Wiring (2014 NEC) (Homestudy) Oregon Electrical License This course will cover the requirements in the 2014 NEC for installing electrical systems in dwelling units. Code sections for residential
More informationIEC and NCCER Mapping for Year 1
Craft: 26102-14 Safety IEC and NCCER Mapping for Year 1 Perform a visual inspection on various types of ladders 102.4 STATE GENERAL SAFETY CONSIDERATIONS IN ELECTRICAL INSTALLATIONS (LADDER SAFETY, SLECTION
More informationInstructor: L. Keith Lofland
One and Two Family Dwelling Electrical Systems 2014 NEC AFCIs, GFCIs, and Other Dwelling Unit Requirements Training Presentation by: International Association of Electrical Inspectors Instructor: L. Keith
More informationUnits 2, 3, 4, 5, 6, 8, 9, 10, Electrical Wiring Residential Unit 2 (Unit 5 Fourth Edition)
Units 2, 3, 4, 5, 6, 8, 9, 10, 11-22 Electrical Wiring Residential Unit 2 (Unit 5 Fourth Edition) 1. What is an outlet? Point on a wiring system where current is taken to supply utilization equipment 2.
More informationSDEC 2017 Questions, Group 1
SDEC 2017 Questions, Group 1 1. Do the factory wings that many fluorescent troffers have designed to fold out over the grid meet the requirements for securely fastened to the framing? Answer: NEC 410.36(B)
More informationResidential Wiring According to the 2011 NEC
Residential Wiring According to the 2011 NEC Utah Electrical License This course will cover the requirements in the 2011 NEC for installing electrical systems in dwelling units. Code sections for residential
More informationSMALL HOMES COUNCIL - BUILDING RESEARCH SERIES 4.2 ELECTRICAL WIRING
SERIES 4.2 ELECTRICAL WIRING ISSUED BY THE SMALL HOMES COUNCIL - BUILDING RESEARCH COPYRIGHT,, 1964, BY THE UNIVERSITY OF ILLINOIS. All rights reserved. be reproduced in ony form without permission in
More informationResidential Wiring (2017 NEC) (Homestudy)
Residential Wiring (2017 NEC) (Homestudy) Idaho Electrical License This course will cover the requirements in the 2017 NEC for installing electrical systems in dwelling units. Code sections for residential
More informationTABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19
TABLE OF CONTENTS About This Textbook...xiii How to Use the National Electrical Code... 1 Article 90 Introduction to the National Electrical Code... 7 90.1 Purpose of the NEC... 7 90.2 Scope of the NEC...
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Is low voltage cable allowed to be run through drilled
More informationNEC Study Guide CORRECT: C NEC (A)(1)
1 According to the NEC, the maximum distance from the point of entrance to the building that the water pipe may be used as a grounding electrode interconnect is: A. 3' B. 4' C. 5' D. 6' CORRECT: C NEC
More informationS U B S T I T U T E O R D I N A N C E BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: ARTICLE I ELECTRICAL CODE
S U B S T I T U T E O R D I N A N C E BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: This ordinance is organized into eight Articles, as follows: Article I. Article II. Article III. Article
More informationMunicipal Code of Chicago TITLE 14E ELECTRICAL CODE
Municipal Code of Chicago TITLE 14E ELECTRICAL CODE Ch. 14E-1 General Ch. 14E-2 Wiring and Protection Ch. 14E-3 General Requirements for Wiring Methods and Materials Ch. 14E-4 Equipment for General Use
More information2010 Residential Ques. & Ans.
1.I am replacing several existing receptacles in an older apartment building because they no longer hold the plug securely. Do I need to install tamper resistant receptacles? Ans. No 406.11, 210.52, Comm.
More informationNEC CODE QUESTIONS. Western Section IAEI 103 rd Annual Meeting September 17-19, 2007
NEC CODE QUESTIONS Western Section IAEI 103 rd Annual Meeting September 17-19, 2007 1. Can a fire pump controller be fed from a UPS? Or is a separate service and separate transfer switch required? 2. Section
More informationMichigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013
Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013 1. Is a standard wire-nut approved for a wet location as in an outside j-box? Is there a listed
More informationStudent Guide. Wiring Edition. Compliments of. Georgia EMC East Exchange Place Tucker, GA (770)
Student Guide to Wiring 2017 Edition Compliments of Georgia EMC 2100 East Exchange Place Tucker, GA 30084 (770) 270-6950 www.georgiaemc.com Electric Membership Cooperatives of Georgia In Georgia, the 41
More informationNEC CODE QUESTIONS and ANSWERS Wisconsin Chapter IAEI Green Lake, Wisconsin May 16-18, 2012
NEC CODE QUESTIONS and ANSWERS Wisconsin Chapter IAEI Green Lake, Wisconsin May 16-18, 2012 1. Can we install 120 Volt conductors in the same space with 277 Volt conductors? If the answer is yes, are there
More informationCOMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods
1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,
More informationChapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...
Article 90 Introduction...1 90.1 Purpose of the NEC...1 90.2 Scope of the NEC...2 90.3 Code Arrangement...4 90.4 Enforcement...5 90.5 Mandatory Requirements and Explanatory Material...6 90.6 Formal Interpretations...6
More informationElectricity Unit Notes. Agriculture Mechanics I
Electricity Unit Notes Agriculture Mechanics I Principles of Electricity Electricity is a form of energy that can produce light, heat, magnetism, chemical changes Resistance: tendency of a material to
More informationRevisions for the 2011 National Electrical Code - Part 1
PDHonline Course E355 (3 PDH) Revisions for the 2011 National Electrical Code - Part 1 Instructor: Patrick Ouillette 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone &
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0519 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationSECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)
SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill
More informationMechanical Systems Submittal Guide
5200 Dover Center Road 440-777-8000 North Olmsted, OH 44070 North-Olmsted.com Mechanical Systems Submittal Guide Residential Code of Ohio (RCO) n applicant is free to submit any mechanical systems description
More informationSecond Revision No. 601 NFPA [ Section No [Excluding
Second Revision No. 601 NFPA 70 2015 [ Section No. 300.4 [Excluding any Sub Sections] ] Where subject to physical damage, conductors, raceways, and cables shall be protected. Informational Note: Minor
More informationProgram, Code Panel Questions, & Survey/Comments
NORTH CAROLINA ELECTRICAL INSTITUTE 90 th ANNUAL MEETING APRIL 9 th 10 th, 2019 HILTON NORTH RALEIGH RALEIGH, NORTH CAROLINA Program, Code Panel Questions, & Survey/Comments Opinions of the Code Panelist
More informationIMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016
IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS June 17th, 2016 RE: City Council Adopts 2014 National Electrical Code with Pool Alarm Requirements On April 25th, 2016 the
More informationNATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY
A new twist on the National Electrical Code - a practical application workshop. If you sign up in this class, prepare to work! Day 1: Fundamentals of OSHA requirements for performing electrical work -
More informationSW District 1. 1 Tony Tadysak Craig Mulder
STATE OF WISCONSIN Department of Safety and Professional Services 1400 E Washington Ave. Madison WI 53703 Web: dsps.wi.gov Governor Scott Walker Secretary Dave Ross Electrical Program Web: Electrical Program
More informationInformational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017
Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017 It has come to the attention of the electrical authorities having jurisdiction (AHJs) at the DOE sites there is inconsistency
More informationA HOMEOWNERS HANDBOOK
ELECTRICAL A HOMEOWNERS HANDBOOK By Everett H. Rawlings Electricity in the home plays a critical role in our lives. From activating our alarm clock in the morning to all aspects of our lives for the rest
More informationRevisions for the 2011 National Electrical Code - Part 4
PDHonline Course E358 (3 PDH) Revisions for the 2011 National Electrical Code - Part 4 Instructor: Patrick Ouillette 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone &
More informationLevel I Chapter 1 Worksheet
Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the
More informationTABLE 1-E (2017) Effective July 1, 2017
TABLE 1-E (2017) Effective July 1, 2017 Oregon Amendments to the 2017edition of the National Fire Protection Association (NFPA) 70, National Electrical Code (NEC) for the 2017 Oregon Electrical Specialty
More informationMEDIUM, LOW AND CONTROL VOLTAGE CABLES
Related Sections U-M Design Guideline Sections: 260800 - Electrical Acceptance Tests Products Medium Voltage Primary Cables Primary power distribution cable shall be single conductor stranded copper, with
More informationTABLE LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE Uncovered Parking Areas. Building Grounds. Walkways 10 feet wide or greater
TABLE 9.4.5 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE 90.1 Uncovered Parking Areas Parking Lots and drives Building Grounds Walkways less that 10 feet wide Walkways 10 feet wide or greater
More informationTown of Cicero Local Code Amendments
Town of Cicero Local Code Amendments 2009 International Residential Code Local Amendments: DELETE Table R302.1 (Exterior Walls), see Attachment A. DELETE Exception for Subsection R313.2 (One and Two-Family
More informationDIVISION 16 ELECTRICAL
DIVISION 16 ELECTRICAL Saratoga Springs / standards / 02-2004 Page - 0 ELECTRICAL SECTION 16060 GROUNDING AND BONDING PART 1 GENERAL 1.01 SECTION INCLUDES A. Grounding electrodes and conductors, equipment
More informationBUILDER S PRE-INSPECTION CHECKLIST
Warrenton Fire Protection District 606 Fairgrounds Rd. Warrenton, MO 63383 Ph: 636-456-8935 Fax: 636-456-7764 www.warrenton-fire.org BUILDER S PRE-INSPECTION CHECKLIST This checklist is designed as a general
More informationFire Alarm Systems ARTICLE. Introduction to Article 760 Fire Alarm Systems. Part I. General
ARTICLE 760 Fire Alarm Systems Introduction to Article 760 Fire Alarm Systems Article 760 covers the installation of wiring and equipment for fire alarm systems, including all circuits controlled and powered
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44
More informationInstallation Instructions. For the 18 Built-In Dishwasher and Front Color Panels
Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,
More informationElectrical Tech Note 107
Electrical Tech Note 107 Biosystems & Agricultural Engineering Department Michigan State University Understanding the Construction Code Rules, Part 8 1 Based on the 2014 NEC and the 2015 MRC The State
More informationP-16 ENGINEER NO. DATE DESCRIPTION 1 01/19/2016 FOR CONSTRUCTION 2 03/11/2016 REVISION # 2 DRAWN BY: CHECKED BY: DATE: SCALE: DRAWING NUMBER
PRESSIONAL P-16 PRESSIONAL PRESSIONAL PRESSIONAL 1 ONE LINE DIAGRAM 3 EMEGENCY LIGHTING SCHEME 2 FEEDER SCHEDULE PRESSIONAL PRESSIONAL PRESSIONAL PRESSIONAL LOCAL SINGLE POLE SWITCH 3-WAY SWITCH 3-WAY
More informationTOM BURNS, PLANNING DIRECTOR
~~ 0 173 COUNTY OF SANTA CRUZ August 4,2005 PLANNING DEPARTMENT 701 OCEAN STREET, qth FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 TOM BURNS, PLANNING DIRECTOR Agenda:
More informationIntellectual Properties, Trademarks and Copyrights
Intellectual Properties, Trademarks and Copyrights ExamREVIEW.NET (a.k.a. ExamREVIEW) is an independent content developer not associated/affiliated with the certification vendor(s) mentioned throughout
More informationCODE PANEL QUESTIONS
NORTH CAROLINA ELECTRICAL INSTITUTE 89 th ANNUAL MEETING APRIL 3-4, 2018 HILTON NORTH RALEIGH RALEIGH, NORTH CAROLINA CODE PANEL QUESTIONS Opinions of the Code Panelist are NOT interpretations issued by
More informationContinuing Education, For UDC Electrical Inspectors, Commercial Electrical Inspectors, Master Electricians and Journeyman Electricians.
Continuing Education, For UDC Electrical Inspectors, Commercial Electrical Inspectors, Master Electricians and Journeyman Electricians. The following test is for Continuing Education Credits for the abovementioned
More informationInspection Report 123 My Street Midland, GA
Buying, Selling or Building Your Home Inspection Company ROFESSIONAL INSPECTION SERVICES, LLC P.O. Box 9774 Columbus, GA 31908 706-565-0333 1-866-298-4251 Inspection Report 123 My Street Midland, GA This
More informationThe following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on
HOME PROPERTY SCAN INSPECTIONS The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on January 11, 2010 and
More informationSubpanels. Bring Big Amps to Distant Spaces. A subpanel is a secondary breaker box BY CLIFFORD A. POPEJOY
Subpanels A subpanel is a secondary breaker box Instead of originating at the main service panel, electrical circuits can begin at a nearby subpanel that is powered from the main panel through one heavy-gauge
More informationNational Electrical Code Forum. Your Questions Answered
National Electrical Code Forum Your Questions Answered Meet Your Distinguished Experts Moderator: Lloyd Osborn- Cheyenne, Wyoming Tom Lichtenstein Republican Organizer-Chicago, IL Tim McClintock NFPA Regional
More informationAxiom Property Inspections
Cover Page Axiom Property Inspections Property Inspection Report 868 Wally Avenue, Henderson NV, 89178 Inspection prepared for: John Doe Agent: David Lawson - Axiom Inspection Date: 8/12/2010 Time: 2:30
More informationPart Two. Wiring Procedures CHAPTER 3. Design and Layout
Part Two. Wiring Procedures CHAPTER 3 Design and Layout The different wiring systems in common use for civilian and armed-forces construction are often called cable and conduit systems. Chapters 4 and
More informationTECHNICAL ARTICLE. Inspecting Existing Dwelling Electrical Systems Using NFPA 73 by Skip Walker September 2009
TECHNICAL ARTICLE Inspecting Existing Dwelling Electrical Systems Using NFPA 73 by Skip Walker September 2009 Many inspectors were contractors in some prior life. The progression from contractor to inspecting
More informationfieldwork report contains the Functional
December 6, 2010 Dear Bill and Ann, On October 2, 2010, Cities Inspection Service, Inc. completed a home inspection of the property located at 2344 Arbour Lane, St. Paul, Minnesota for you. Doug Hastings
More informationImportant Upcoming Dates
2011 NEC ROP Report NFPA Conference and Expo Chicago, IL June 9, 2009 Important Upcoming Dates ROP Available: On or about 6/19 Comment Closing Date: 10/23@ 5:00PM EDT ROC Meeting: 12/2 12 TCC ROC Meeting:
More information2014 National Electrical Code & NFPA 70E/Arc Flash
Gain an understanding of the 2014 NEC s latest additions, revisions and changes. Learn the precautions needed when working with and around electricity. People and property need to be safeguarded from the
More informationPHILADELPHIA REGIONAL PORT AUTHORITY VOLUME 2 SPECIFICATIONS FOR VEHICLE PROCESSING FACILITY NAVAL BUSINESS CENTER PHILADELPHIA PA.
PHILADELPHIA REGIONAL PORT AUTHORITY VOLUME 2 SPECIFICATIONS FOR VEHICLE PROCESSING FACILITY NAVAL BUSINESS CENTER PHILADELPHIA PA Prepared By STV Incorporated 205 West Welsh Drive Douglassville, PA 19518
More information1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109
1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109 INFRARED VIEW OF HOME Attention: Mr. John Smith SUBJECT PROPERTY The following inspection of a property located at 1710 Anywhere Drive, Montgomery, AL 36109, was
More informationEFCOG Best Practice #213
EFCOG Best Practice #13 Facility: DOE Complex Best Practice Title: Adoption of NFPA 70 017 in place of NFPA 70 014 Point of Contact: Michael Hicks NE-ID, 08-56-374, hicksmd@id.doe.gov John McAlhaney SRS,
More informationSECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.
SECTION 26 0553 PART 1 GENERAL 1.1 SECTION INCLUDES A. Electrical identification requirements. B. Identification nameplates and labels. C. Wire and cable markers. D. Voltage markers. E. Underground warning
More informationll. Consistency Questions
Our Goal is FOR ALL STAKEHOLDERS TO HAVE A SUCCESSFUL PROJECT with us and that together we keep people and structures safe and buildings economically viable to serve the needs of our community. We strive
More informationCorra/Clad MC Cable The contractors cable of choice in place of conduit and wire.
Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire. Installs fast and easy Lowers labor costs Replaces conduit and wire Provides superior grounding UL Listed Corra/Clad MC
More informationFee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours
www.garyklinka.com Page 1 of 9 Instructions: Fee $15 1. Print these pages. 2. Circle the correct answers and transfer them to the answer sheet. 3. Page down to the last page for the verification forms
More informationCORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES
CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,
More informationElectrical Code Incorporating the 2014 International Building Code as amended
VILLAGE OF LIBERTYVILLE Municipal Code Chapter 6 Buildings and Technical Regulations Electrical Code Incorporating the 2014 International Building Code as amended Adopted 4/12/16 as part of Ord. 16-O-21
More informationIDENTIFICATION FOR ELECTRICAL SYSTEMS July Electrical Systems
SECTION 26 05 54 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Labels. 3. Wire markers. 4. Conduit markers. 5. Permanent Marking. 6. Underground
More informationSAN JOAQUIN COUNTY ELECTRICAL PLAN CHECK CORRECTION SHEET (209) FAX (209)
SAN JOAQUIN COUNTY ELECTRICAL PLAN CHECK CORRECTION SHEET (209) 468-2098 FAX (209) 468-9907 PERMIT NO: DATE: PROJECT: APPLICANT: OWNER: PHONE #: PHONE # JOBSITE ADDRESS: CHECKED BY: KERMIT L. DARROW, AIA-E
More informationSECTION ELECTRICAL IDENTIFICATION
SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationRESIDENTIAL OVER. 4. Would it be permissible to hard- wire the dishwasher in question 3? If so, under what conditions?
WELCOME TO THE EASTERN SECTION CODE BREAKFAST CODE BREAKFAST QUESTIONS FOR THE EASTERN SECTION ANNUAL MEETING 93 rd ANNUAL EASTERN SECTION MEETING, KING OF PRUSSIA, PA RESIDENTIAL ALL QUESTIONS BASED ON
More informationModule number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire
Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire Suppression Systems; and Chapter 34-National Electric
More informationBUILDER S PRE-INSPECTION CHECKLIST
Warrenton Fire Protection District 606 Fairgrounds Rd. Warrenton, MO 63383 Ph: 636-456-8935 Fax: 636-456-7764 www.warrenton-fire.org BUILDER S PRE-INSPECTION CHECKLIST This checklist is designed as a general
More informationElectrical Essentials corrected calculation slides only
Electrical Essentials corrected calculation slides only IAEI Southern Nevada Chapter/Educode 2015 Electrical Theory 1 Feeders and OCP 5 NEC Structure 2 Service and Grounding 6 Print Reading 3 Fault Current
More informationFIRE ALARM: BY OTHERS, IF REQUIRED.
x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. FLUORESCENT STRIP LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. WALL BRACKET FLUORESCENT
More informationInstallation Instructions
Installation Instructions For the 18" Built-In Dishwasher Sears, Roebuck and Co. Sears Canada, Inc. Hoffman Estates, IL 60179 U.S.A. Toronto, Ontario, Canada M5B 2B8 154435201 Before You Begin DO NOT INSTALL
More informationNEC {CODE CHANGES. OVERVIEW OF 2014 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold
NEC {CODE CHANGES OVERVIEW OF 2014 Related to Electrical Wiring Devices { Cablofil Pass & Seymour Wiremold TABLE OF CONTENTS Page i NEC SECTION DESCRIPTION PAGE 210.8(A)(9) GFCI Protection of Receptacles
More informationSection Electical General Provision
Section 26 05 00 Electical General Provision 26 05 00-1 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Except as modified in this Section, General Conditions, Supplementary Conditions, applicable provisions
More informationAFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?
RECEPTACLEFAQs AFCI 1 What is an arc fault? UL provides a definition for an arc fault in UL 1699 (Standard for Safety Arc Fault Circuit Interrupters). It is an unintentional arcing condition in a circuit.
More informationInspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc
Inspection Report 1 Inspection Way Orlando, FL 32825 Prepared for: Wanda Figueroa Prepared by: Page 1 of 25 Needs Service Summary This summary is not the entire report. The complete report may include
More information