4 4 The company AFRISO Sp. z o.o. was founded in Since that time we keep doing our best to increase AFRISO brand awareness among Installers. That is why in 2010 we ve decided to establish ProControl family - products that were aimed at the heating and domestic water market. But also suitable for cooling, ventilation and solar solutions. Wa are focused on our end user - Installer (plumber). That s why we are continuously monitoring the needs and expectations of customers to adapt our offer to them as they arise. We take care of his perception about brand, his feelings about products, accompanying technical materials and so on. We decided to use sales network of our wholesalers to offer ProControl products. We offer this kind of product also to OEM customers. Focusing on Installer resulted in sales more than pcs of products under AFRISO ProControl brand on Polish market in For example - ARV pcs; ATM pcs and ARM pcs. Therefore we can offer you our high quality products and know-how in selling our solutions to multiply your benefits. Szałsza, near Gliwice ul. Kościelna 7

5 5 Table of contents Thermic valves ATV 4 Rotary mixing valves ARV 6 Electric actuators ARM 10 Constant temperature controllers ACT Weather compensated controller ARC Weather compensated controllers AWC 18 Thermostatic mixing valves ATM 20 Thermostatic mixing valves ATM with bigger Kvs 22 Solarset for preparing d.h.w. ASS 26 Zone valves AZV 28

6 ProControl overview 6 Thermic valves ATV Possibility to exchange all internal elements The valve construction allows to remove all of the internal functional elements to clean out the valve from contamination or exchange its elements. Temperature range fitting your needs Temperature range within C of the water returning to the boiler allows to use the thermic valves in standard installations and in installations with heat storage tanks. Full flow control ATV valves regulate the flow rate on connections A and B, therefore, there is no need to use additional regulating valves. Possibility to work as a diverting valve The ATV valve can also work as a diverting valve when it is mounted between the boiler and a storage tank. It does not allow then to load the storage tank when the temperature of the water leaving the boiler is not high enough. Possibility to change the temperature Thanks to the construction of the valve there is a possibility to exchange its thermostatic element. It enables to change the temperature of the water returning to the boiler.

7 THERMIC VALVES ATV thermic valves ATV The ATV thermic valves are made of brass and have female threads. Inside the valve there is a thermostatic element which regulates the temperature of the water returning to the boiler and keeps it on a constant, minimal level. The opening temperature indicates the temperature at which the ATV valve starts to open its A connection through the thermostatic element. The valve can be mounted in all positions. Application of the ATV valve does not require mounting additional regulating valves on its connections. The constructions of the ATV valve allows to exchange the thermostatic element with no need of dismantling the valve from the installation. 7 TECHNICAL DATA Parameter / piece Pressure class Value / material PN10 Media temperature 5 95 C Differential pressure Internal leak rate A - AB B - AB Glycol concentration max 50% max 100 kpa (1 bar) max 1% Kvs (Δp 100 kpa) max 3% Kvs (Δp 100 kpa) Body Nut O-rings brass CB753S brass CW617N EPDM TABLE OF ATV VERSIONS Art.-Nr type DN * Rp internal threads Kvs [m 3 /h] connections* ATV Rp 1 45 C ATV Rp 1 50 C ATV Rp 1 55 C ATV Rp 1 60 C ATV Rp 1¼ 45 C ATV Rp 1¼ 50 C ATV Rp 1¼ 55 C ATV Rp 1¼ 60 C opening temperature MOST COMMON APPLICATION A The ATV thermic valves are designed to efficiently load storage tanks and protect the solid fuel boilers from too low temperature of the returning water. If it is lower than the producer of the boiler recommends, it can cause smaller efficiency, corrosion, tarring and sooting which eventually brings to a shorter life span of the boiler. The ATV valve causes that water circulates in the short circuit until the boiler gains the required temperature. After the temperature is appropriate, the valve opens its B connection and loads the tank, also keeping the required temperature of the water returning to boiler. AB B

8 ProControl overview 8 Rotary mixing valves ARV Low torque required Very low torque is required to rotate the valves. Therefore actuators are slightly charged, what increases their lifespan. Sleeve valve position indicator The thicker, raised part of the valve knob defines the position of the sleeve inside the valve. This makes the setting and controlling of the valve easier. Legible scale The legible scale, located on the cover of the valve knob, allows to precisely determine the ARV valve position. Each valve comes with two covers with following scales: first scale from 0 to 10 and second from 10 to 0. They allow the valve to operate in different assembling positions. The non-slip material knob Made of special plastic, the knob allows easy and precise setting of the valve in manual mode.

9 ROTARY MIXING VALVES ARV The 3-way and 4-way rotary mixing valves ARV with female threads are made of brass. They are equipped with knobs for manual operation. Wide range of sizes gives the possibility to choose a valve that fits client s needs. The ARV valves have a limiting ring which restricts the rotation angle and makes the setup of the valves easier. You can automate the work of the valves by using electric actuators ARM. ARV valves can be used as mixing valves and also as diverting valves in all types of installations. TECHNICAL DATA 3 and 4-way rotary mixing valves ARV 9 Parameter / piece Pressure class Value / material PN10 Media temperature C Differential pressure Internal leak rate max 100 kpa (1 bar) max 1,5% (Δp 50 kpa) Glycol concentration max 50% Body O-rings brass CW617N EPDM Rotation angle 90 Required torque min 1 Nm for DN20 DN32 min 2 Nm for DN40 DN50 3-WAY ROTARY MIXING VALVES ARV Art.-Nr type DN Kvs [m 3 /h] ARV Rp ¾ ARV ,3 Rp ¾ ARV Rp ARV Rp 1 connections* ARV Rp 1¼ ARV Rp 1½ ARV Rp 2 4-WAY ROTARY MIXING VALVES ARV Art.-Nr type DN Kvs [m 3 /h] ARV Rp ARV Rp 1 connections* ARV Rp 1¼ ARV Rp 1½ ARV Rp 2 * Rp internal threads

10 ProControl overview 10 3 and 4-way rotary mixing valves ARV MOST COMMON APPLICATIONS The 3-way rotary mixing valve ARV mixes the hot water coming from the boiler with cold water returning from the installation. Thanks to that you can regulate temperature of the water flowing to the installation. The 3-way rotary mixing valve ARV distributes the water coming from the installation between the return to the boiler and the supply of the installation. Thanks to that you can regulate the temperature of the water flowing to the installation. The 3-way rotary mixing valve ARV diverts the hot water from the boiler to the supply of the heating installation or to the storage tank loading it.

11 3 and 4-way rotary mixing valves ARV 11 The 4-way rotary mixing valves ARV are designed to raise the temperature of the water flowing back to the boiler. The hot water from the boiler is mixed with the cold water returning from the installation simultaneously increasing the temperature of the water returning to the boiler. It helps to achieve a higher efficiency of the whole installation and also prevents corrosion, tarring and sooting of the boiler. ARV 3 AND 4-WAY REGULATING SETS The 3-way and 4-way rotary mixing valves ARV are designed to work with electric actuators ARM. There are regulating sets that include the ARV valve and the most popular actuator ARM 343 (230 V AC, 3-point, 120 s, 6 Nm). REGULATING SETS Art.-Nr type DN Kvs [m 3 /h] connections* ARV ARM ,3 Rp ¾ ARV ARM Rp ARV ARM Rp 1 ¼ Rotary mixing valve ARV ARV ARM Rp 1 ½ ARV ARM Rp ARV ARM Rp ARV ARM Rp 1 ¼ ARV ARM Rp 1 ½ ARV ARM Rp 2 * Rp internal threads Electric actuator ARM 343

12 ProControl overview 12 Electric actuators ARM LEDs signaling the state of the actuator Colour signaling LEDs determine the rotation direction of the ARM actuator and inform when the auxiliary switch is on. Electric wires marked with colours ARM actuator electric wires are marked with colours. Due to that mounting is easier and it also prevents mistakes. Mode switch Using the switch it is possible to choose between automatic and manual mode. Protection against damage of the actuator caused by valve jamming A built-in system prevents ARM actuators from damaging caused by jamming of the valve. It extends the lifespan of the actuator. Legible scale The legible scale located on the cover of the ARM actuator knob allows precise opening of the valve. Each actuator comes with two knob covers with the following scales: one with the scale from 0 to 10 and the second with the scale from 10 to 0. It allows the actuator to work in various mounting positions. Soft operation Thanks to a special grease on the racks, the ARM actuator works silently. It excludes the necessity of its installation in soundproofed rooms and extends its lifespan.

13 ELECTRIC ACTUATORS ARM The ARM electric actuators are designed for operating 3 and 4-way rotary mixing valves. They are made in many useful configurations. The torque value can be 6, 10 or 15 Nm. The actuator can be operated manually. The auxiliary switch is also an option. Thanks to the scale on the knob you always know in which position the actuator currently is. LED diodes on the body are signaling the direction in which the actuator is turning. The ARM actuators also have a system protecting the device in case of valve blockage. They are delivered with a 2 meter electric wire. TECHNICAL DATA electric actuators ARM 13 Parameter / piece Value / material Torque 6 Nm, 10 Nm, 15 Nm 230 V AC (2 and 3-point) Voltage 24 V AC (2 and 3-point) 24 V AC/DC (proportional) Operating range 90º Running time s, 30 s, 60 s, 90 s, 120 s, 240 s Auxiliary switch optional (settable 0 90 ) Ambient temperature 0 50ºC Power consumption Protection class Enclosure rating 2,5 4 VA II IP42 THE MOST POPULAR ELECTRIC ACTUATORS ARM Art.-Nr type voltage running time 90 [s] torque [Nm] control signal ARM V AC point SPDT ARM V AC point SPDT ARM V AC point SPST ARM V AC/DC 60/90/ proportional* *control signals: V, V, ma, ma In the table above these are the most popular versions of the electric actuators ARM. Other combinations of parameters are availabe on request. SCOPE OF SUPPLY: actuator ARM with knob and pre-mounted scale from 0 to 10 additional scale from 10 to 0 mounting set for valves: ARV AFRISO, ESBE (MG, G, F), Seltron, Somatherm, Hora, WIP, PAW, LK, BRV, IMIT, IVAR, HOVAL, OLYMP user s manual Other mounting sets are available on request.

14 ProControl overview 14 Constant temperature controller ACT Mode switch Using the switch it is possible to choose between automatic and manual mode. Temperature display The display allows to check the set and measured temperature of the mixed water. Touch panel The touch buttons easily allow to set the parameters of the regulator. Full control In ACT 443 the pre-mounted electric wire for pump control and additional sensor for the heat source enable more effective regulation of the installation. Ready to mount The pre-mounted electric wire with plug and pipe temperature sensor shorten the time needed to mount the regulator and guarantee proper electric connections. Constant temperature controller ACT with actuator In one housing you get the constant temperature controller and electric actuator to operate 3 and 4-way rotary mixing valves of various producers. LEDs signaling the state of the actuator Colour signaling LEDs determine the rotation direction of the actuator and inform in case of error or sensor failure.

15 CONSTANT TEMPERATURE CONTROLLER ACT The ACT controller is a modern unit with a built-in actuator designed for 3 and 4-way rotary mixing valves to maintain the constant temperature of the mixed water. It is equipped with touch buttons to set the required temperature and navigate through the menu. Wide temperature range (0 99 C) and the ability to switch modes gives the possibility to use this controller in heating and cooling installations. It also gives the possibility to display the set or the currently measured temperature of the water. With ACT 443 you can additionally control the pump and measure the heat source temperature for better regulation. TECHNICAL DATA constant temperature controller ACT 15 Parameter / piece Voltage Value / material 230 V AC Operating range 90 Ambient temperature 5 85 C Power consumption Protection class Enclosure rating Modes of operation Electric wire length Pipe sensor length Heat source sensor length (ACT 443) Pump wire length (ACT 443) 1,5 VA I IP42 heating or cooling 2 m 1 m 4 m 0,6 m TABLE OF ACT VERSIONS Art.-Nr type voltage running time 90 torque temperature range ACT V AC 120 s 6 Nm 0 99 C ACT V AC 120 s 6 Nm 0 99 C SCOPE OF SUPPLY: actuator ACT with knob and pre-mounted scale from 0 to 10 additional scale from 10 to 0 two mounting sets for valves: 1. ARV AFRISO, ESBE (MG, G, F), Seltron, Somatherm, Hora, WIP, PAW, LK, BRV, IMIT, IVAR, HOVAL, OLYMP 2. ESBE VRG, Danfoss HRB user s manual Other mounting sets are available on request. LOCATION OF THE TEMPERATURE SENSOR ACT 343 ACT 443 T2 230 V AC T1 T2 230 V AC 230 V AC T1

16 ProControl overview 16 Weather compensated controller ARC Pre-mounted electric wire The pre-mounted wire with electric plug shortens the time required to mount the controller and guarantees proper electric connections. Backlit touch screen The backlit touch screen enables a very easy setup of the controller even in dark boiler rooms. Set of temperature sensors The controller is delivered with the set of all temperature sensors required for the proper work of the unit. The immersion and contact sensors are delivered with pre-mounted electric wires. Weather control with actuator In one housing you get the weather controller and electric actuator to operate 3 and 4-way rotary mixing valves of various producers.

17 WEATHER COMPENSATED CONTROLLER ARC The ARC is a modern weather control unit with a build-in actuator. It is designed for controlling 3 or 4-way rotary mixing valves and circulating pumps. With a torque 10 Nm it can work with various valve sizes. It allows to operate the valve in manual mode. The ARC is the first regulator with a touch screen and therefore it is very easy to handle. Thanks to the programed installation schemes the start-up of the installation is very fast and requires only mounting the unit, connecting the temperature sensors and picking the scheme. The rest of the setups can be entered in a few quick steps in the menu. TECHNICAL DATA weather compensated controller ARC 17 Parameter / piece Voltage Circulation pump control Switching type Value / material 230 V AC 230 V AC / 4 (2) A tip 1B Operating range 90 Ambient temperature 0 40 C Power consumption Protection class Enclosure rating Electric wire length Pump wire length max 4 VA II IP42 1,9 m 0,6 m TABLE OF ARC VERSIONS Art.-Nr type voltage running time 90 torque ARC V AC 120 s 10 Nm auxiliary switch SCOPE OF SUPPLY: controller ARC with pre mounted electric wires two mounting sets for valves: 1. ARV AFRISO, ESBE (MG, G, F), Seltron, Somatherm, Hora, WIP, PAW, LK, BRV, IMIT, IVAR, HOVAL, OLYMP 2. ESBE VRG, Danfoss HRB set of temperature sensors (3 m contact sensor, 3 m immersion sensor, outdoor temperature sensor) user s manual Other mounting sets are available on request. LOCATION OF THE TEMPERATURE SENSORS T2 T3 T2 230 V AC T4 230 V AC T4 T3 T2 outdoor sensor T3 contact sensor T4 immersion sensor

18 ProControl overview 18 BUS connection Weather compensated controller AWC With BUS-connection it is possible to make a network out of AWC and ARC controllers. That means less temperature sensors are required. Big variety of schemes You can choose between many hydraulic schemes and AWC 440 gives the possibility of controlling 2 mixing circuits simultaneously. Electronic relay A triac output is available in both versions of AWC for controlling the speed of pumps. Set of temperature sensors The AWC controllers are delivered with 3 temperature sensors required for the basic work of the unit the outdoor, immersion and contact sensors.

19 WEATHER COMPENSATED CONTROLLER AWC The AWC is a modern weather compensated controller for heating circuits, domestic hot water systems, boilers and solar systems. It has 17 (AWC 410) or 52 (AWC 440) preset hydraulic schemes to choose from. AWC 440 can control two mixing circuits simultaneously. Both versions are equipped with a triac output for pumps. The setup is fast and easy thanks to the setup wizard known also from the ARC controller. TECHNICAL DATA Parameter / piece Voltage Power consumption Relay output Value / material 230 V AC < 5 VA 4 (1) A, 230 V AC weather compensated controller AWC 19 SCOPE OF SUPPLY: controller AWC set of 3 temperature sensors (contact sensor, immersion sensor, outdoor temperature sensor) user s manual Triac output 1 (1) A, 230 V AC Ambient temperature 5 40 C Controller housing Protection class Enclosure rating ASA - thermoplastics I IP20 Electric wires 0,75 1,5 mm 2 Sensor length max 30 m TABLE OF AWC VERSIONS Art.-Nr type voltage hydraulic schemes mechanical relays AWC V AC AWC V AC Other temperature sensors must be ordered depending on the chosen hydraulic scheme. EXAMPLE APPLICATIONS electronic relays T2 2 GND 4 GND T4 29 N 3 T3 25 N 26 N N T6 6 GND AWC 410 controls the mixing valve, heating circulation pump, storage tank loading pump, d.h.w. circulation pump. GND T5 5 GND 6 GND T2 3 GND T3 2 GND 4 GND 25 N 26 N 27 T N 30 N 31 T6 28 N T5 5 GND AWC 440 controls two mixing valves, two heating circulation pumps, storage tank loading pump.

20 ProControl overview 20 Double scale Thermostatic mixing valves ATM The double legible scale with temperatures of mixed water and set points helps to preset the proper temperature of mixed water and guarantees the correct functioning of the ATM valve. Socket for the Allen key Socket for the Allen 7 mm key allows to easily change the position of the knob. Especially in the case of difficult access to the valve's top. Inspection window Window at the top of the protective cover gives the possibility to check the valve's presetting. Especially important when the valve's cap is locked with the a seal. Protective cover Every ATM valve comes with a cover for the temperature adjustment knob. It eliminates the possibility of accidental changes in temperature. The seal lock gives the possibility to lock the cover when the valve's presetting should be protected. Innovative internal construction Different types Three types of connections and two Kvs factors allow to pick valves for almost all standard applications. As an additional option fittings with non-return valves are available. Thanks to the new, innovative construction, ATM valves work perfectly in hard dynamic pressure conditions and are more resistant to impurities. An additional protection spring secures the thermostatic element against overheating.

21 THERMOSTATIC MIXING VALVES ATM The ATM thermostatic mixing valves are intended to regulate the temperature of mixed water. ATM valves can be installed before water taps or showers. The ATM thermostatic mixing valves should be used always when a need to protect the users from scalding or a fast reaction to temperature or pressure changes is required. The ATM valves also give the possibility to safely heat the water up in tap water systems to prevent from the Legionella. The anti-scald function closes the hot water inlet in case of cold water lack. Thermostatic mixing ATM valves can be also used in underfloor heating systems as mixing valves before manifolds. They can be used with pure water or mixtures of water and glycol in concentrations of up to 50%. The ATM valves can be mounted in all positions. The valves with bottom mix are additionally nickel-plated. There are also fittings for valves G ¾ and G 1 available. Two of the three fittings in the set contain build-in non-return valves for hot and cold water connections. TECHNICAL DATA thermostatic mixing valves ATM 21 Parameter / piece Value / material Static working pressure max 10 bar Dynamic working pressure max 5 bar Differential pressure (ratio) 2:1 Working temperature max 90 C (temporarily 110 C) Temperature range C or C Kvs 1,6 m³/h, 2,3 m³/h or 2,5 m³/h Mixing accuracy ±2 C Body dezincification resistant brass (DZR) Glycol concentration max 50% Required flow rate min 6 l/min THERMOSTATIC MIXING VALVES ATM, side mix Art.-Nr type DN connections* temperature range Kvs [m 3 /h] ATM G ¾ C 1, ATM G ¾ C 1, ATM G C 1, ATM G C 1, ATM Rp ¾ C 1, ATM Rp ¾ C 1, ATM G C 2, ATM G C 2,5 THERMOSTATIC MIXING VALVES ATM, nickel-plated, bottom mix ATM G C 2, ATM G C 2,3 *Rp female thread, G male thread Setting the mixed water temperature on the thermostatic mixing valves ATM is very simple. Every number on the scale has its corresponding mixed water temperature as in the tables that follow: Side mix valves temperature** setting range C range C 1 20 C 35 C 2 25 C 44 C 3 29 C 48 C 4 33 C 52 C 5 37 C 56 C 6 43 C 60 C temperature** setting range C range C 1 20 C 35 C 2 24 C 40 C 3 28 C 45 C 4 33 C 52 C 5 38 C 57 C 6 43 C 60 C ** accuracy is ±2 C

22 ProControl overview 22 Thermostatic mixing valves ATM with bigger Kvs Double scale The double legible scale with temperatures of mixed water and set points helps to preset the proper temperature of mixed water and guarantees the correct functioning of the ATM valve. Protective cover Every ATM valve comes with a cover for the temperature adjustment knob. It eliminates the possibility of accidental changes in temperature. The seal lock gives the possibility to lock the cover when the valve s presetting should be protected. Inspection window Window at the top of the protective cover gives the possibility to check the valve's presetting. Especially important when the valve's cap is locked with the a seal. Anti-scald function Lack of cold water flow causes the inlet of hot water to shut off. Bigger Kvs value Kvs values 3,2 and 4,2 allow to use the ATM valves in big domestic water regulating systems. Mixed water flows out from the side of the valve A mixed water stream flows out from the side connection of ATM valve. It enables the valve to be mounted very easily.

23 THERMOSTATIC MIXING VALVES ATM WITH BIGGER Kvs thermostatic mixing valves ATM The bigger ATM thermostatic mixing valves are made of brass. They have a knob with a legible double scale for setting the required mixed water temperature in range C or C. The plastic cover with a seal lock feature eliminates the possibility to accidentally change the temperature. The anti-scald function closes the hot water inlet in case of cold water lack. The ATM valves can be mounted in all positions. The ATM thermostatic mixing valves should be used always when there is a need to protect the users from scald and a fast reaction to temperature or pressure changes. The ATM valves also let to safely heat the water up in the tap water systems to prevent from the Legionella bacteria. 23 The ATM valves with higher Kvs value are especially intended for bigger domestic hot water installations and underfloor heating systems. TECHNICAL DATA Parameter / piece Static working pressure Value / material max 10 bar Dynamic working pressure Media temperature C C max 5 bar max 90 C max 110 C Temperature stability ± 3 C Material brass CW617 and CW614 Glycol concentration max 50% Required flow rate min 9 l/min TABLE OF BIGGER ATM VERSIONS Art.-Nr type DN connections* * G male thread temperature range ATM G C 3, ATM G C 3, ATM G 1 ¼ C 4, ATM G 1 ¼ C 4,2 Kvs [m 3 /h] Setting the mixed water temperature on the thermostatic mixing valves ATM is very simple. Every number on the scale has its corresponding mixed water temperature as in the table that follows: temperature** setting range C range C 1 20 C 35 C 2 25 C 40 C 3 30 C 47 C 4 34 C 51 C 5 39 C 56 C 6 43 C 60 C ** accuracy is ±3 C

24 ProControl overview 24 most common applications for ATM VALVES MOST COMMON APPLICATIONS The ATM thermostatic mixing valve maintains the constant (set) hot water temperature in several water taps. You can choose between the temperature range C or C depending on the installation. The ATM thermostatic mixing valve maintains the constant (set) temperature in the circulation circuit for several water taps. You can choose between the temperature range C or C depending on the installation. The ATM thermostatic mixing valve maintains the constant (set) temperature in the water tap. You can choose between the temperature range C or C depending on the installation. The bottom mix version of the ATM thermostatic mixing valve maintains the constant (set) temperature in the water tap. You can choose between the temperature range C or C depending on the installation. The ATM thermostatic mixing valve maintains the constant (set) temperature in the underfloor heating system. The valves with the temperature range C are used for surface heating installations.

25 temperature characteristics for ATM VALVES 25 TEMPERATURE CHARACTERISTICS Outlet temperature [ C] Graph on the left: Just after a few seconds from opening the water flow through the valve, the outlet temperature stabilizes on the proper level Time [s] Graphs below: Three graphs show how the ATM valve reacts to sudden cold or hot water pressure changes. The mixed water temperature graph clearly shows that even when the pressure fluctuations are very big the mixed water temperature changes are very small. Pressure [bar] Cold water pressure 7,5 6,0 4,5 3,0 1,5 0, Time [s] Pressure [bar] Hot water pressure 7,5 6,0 4,5 3,0 1,5 0, Time [s] Temperature [ºC] Mixed water temperature Time [s]

26 ProControl overview 26 Solarset for preparing d.h.w. ASS Protective cover Every ATM valve comes with a cover for the temperature adjustment knob. It eliminates the possibility of accidental changes in temperature. Knob with scale The legible scale helps to set the proper temperature of the mixed water and guarantees the correct functioning of the ATM valve. Flattening for easy mounting The ATM mixing valve, diverting valve and tee have special flattening for a wrench to make the mounting easier. Anti-scald function Lack of cold water flow causes the inlet of hot water to shut off.

27 SOLARSET FOR PREPARING d.h.w. ASS The solarset ASS is entirely made of brass. It consists of an ATM mixing valve, diverting valve and a tee. The ATM valve has a knob with a legible scale that allows setting the required mixed water temperature in range C. The plastic cover eliminates the possibility of an accidental temperature change. The anti-scald function closes the hot water connection in case of cold water lack. The ATM valve also allows heating safely the water up in tap water systems to prevent from the Legionella bacteria. The solarset ASS can be mounted in all positions. All parts can be rotated by 360. TECHNICAL DATA solarset for preparing d.h.w. ASS 27 Parameter / piece Static working pressure Value / material max 10 bar Medium temperature 5 95 C Temperature range C Kvs 1,5 m 3 /h Temperature stability ± 2 C Diverting valve temperature 45 C ±2 C Connections G1 ATM valve body Diverting valve and tee body Sealing Housing and cover Scald safe brass CW602N (DZR) brass CW617N EPDM ABS yes TABLE OF ASS VERSIONS Art.-Nr type DN * G male thread Kvs [m 3 /h] connections* temperature range ASS ,5 G C 45 C diverting valve temperature APPLICATION SCHEME Diverting valve Additional heat source Tee ATM mixing valve When the temperature at the ASS solarset inlet is lower than 43 C, the diverting valve directs it to the additional heat source. If the temperature on the inlet is between 43 C and 47 C the diverting valve directs some of the water to the additional heat source and some directly to the ATM mixing valve. When the temperature at the ASS solarset inlet is above 47 C, the diverting valve directs all of it to the ATM valve and the additional heat source is not used. The water is mixed to the proper temperature at the ATM valve and then flows to the d.h.w. system.

28 ProControl overview 28 Zone valves AZV Position indicator On the top of the actuator there is an indicator that shows the current position of the internal element. This tells us in which way flows the medium in 3-way valves or whether the valve is open or closed in 2-way valves. Electric wires marked with colours AZV actuator electric wires are marked with colours. Due to that mounting is easier and it also prevents mistakes. Easy to dismount actuator It is easier to install the valve with dismounted actuator. To do so you have to remove the metal buckle and lift the actuator. After mounting the valve, put the actuator back on it. To make it easier it only fits in one position. Resistant to high differential pressure Thanks to the innovative construction of the internal elements the valve is resistant to high differential pressure (up to 3 bar). The internal construction also prevents the valve from blocking when in one positions for a longer period of time. Adapter for 3-way valves An optional adapter for 3-way switching valves AZV is available. It widens the possible medium temperature range to C (temporarily even 160 C).

29 zone valves AZV 29 ZONE VALVES AZV The zone valves AZV consist of two main elements the valve and the electric actuator. The valve body is made of brass and the internal elements from PPS composite. The electric actuator has a pre-mounted 1 metre wire. On the top of the actuator there is the position indicator. The zone valves AZV are designed to be used in heating, solar and air-conditioning installations as switching valves (3-way) or shut-off valves (2-way). They are controlled via SPST signal from any thermostat or other switch. TECHNICAL DATA Parameter / piece Value / material Connections G¾, G1 Kvs 2-way 3-way 11 m 3 /h 8 m 3 /h Differential pressure Working pressure Open/close time (2-way) Switching time (3-way) Valve body Internal elements Internal leakage Medium temperature Ambient temperature max 3 bar max 10 bar 12 s (90 angle) 8 s (60 angle) Brass CW617N and CW614N PPS composite max 1% Kvs 5 80 C (90 C temporarily) 1 60 C Glycol concentration max 50% Actuator supply voltage Power Enclosure rating Control signal Electric wire 230 V AC 7 VA IP40 SPST (2-point) 3 x 0,75 mm 2, isolated, 1 m ZONE VALVES AZV, 2-way shut-off valves, normally open (NO) or normally closed (NC) Art.-Nr type DN connections* Kvs [m 3 /h] position AZV G¾ 11 NC AZV G¾ 11 NO AZV G1 11 NC AZV G1 11 NO ZONE VALVES AZV, 3-way switching valves Art.-Nr type DN connections* Kvs [m 3 /h] AZV G¾ AZV G1 8 * G male thread

30 ProControl overview 30 zone valves AZV Adapter for 3-way switching valves Art.-Nr name/description Adapter for 3-way zone valves AZV which allows to use them with medium temperatures C (160 C temporarily) SAMPLE APPLICATIONS The 2-way shut-off valve combined with a heat tank thermostat in this installation will carry out the priority of heating the domestic water. If the temperature in the heat tank decreases the thermostat will open the valve and the boiler will quickly heat up the tank. After the temperature in the tank rises above this on the thermostat, the valve will close. The 3-way valve in this installation can be controlled via a heat tank thermostat or a controller. If a thermostat is used, the valve will change its position when the temperature of the water in the heat tank changes. When a controller is used, the valve will switch depending on the chosen priority (domestic hot water or heating).

31 31 OEM versions Electric actuators ARM OEM There is an OEM version of the ARM actuator available. It lacks the knob with scale. Instead it has a cover with indicator and range on the blue ring. To turn the device in manual mode an Allen key is helpful. You can order the cover with various logotypes. Thermostatic mixing valves ATM OEM We also have OEM versions of ATM valves intended for big investments. They are without the nickel-plated finishing and have a different design. The available versions come with ¾ or 1 male threads, Kvs 1,6 and temperature ranges of C or C. Nickel-plated thermostatic mixing valves ATM OEM Apart from the OEM ATM valves we can also deliver the standard ATM valves adjusted to our client s needs. There is a possibility to change the logotype on the plastic cover and valve labels.

32 ProControl overview 32 Notes

33

34 Right for making changes reserved. Copyright reserved. Schemas examples for illustrative purposes only A.PP A430.web.eng

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function Solar storage-to-boiler thermostatic connection kit 6-63 series REGI STERED BS EN ISO 900:000 Cert. n FM 64 UNI EN ISO 900:000 Cert. n 0003 CLEFFI 064/09 GB Function The solar storage-to-boiler connection

More information

Mercury Mixing Kit (Code: ME1053)

Mercury Mixing Kit (Code: ME1053) Mercury Mixing Kit (Code: ME1053) The installation and commissioning of the UFH mixing kit system must be exclusively performed by qualified personnel in accordance with the national guidelines and/or

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit Multi-function compact unit for temperature control, thermal disinfection and distribution for hydraulic and domestic water system 6005 series ACEDITED ISO 9001 FM 21654 01160/17GB replaces dp 01160/08GB

More information

HERZ Regulating valve 4002

HERZ Regulating valve 4002 HERZ Regulating valve 4002 Data sheet 4002, Issue 0214 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 42 1 4002 62 1 4002 43 1 4002 63 1 4002 44 1 4002 64 1 4002 45 1 4002 65 1 4002 46 1 4002 66 DN

More information

Partner Valve/High Quality Ball Valve LENO MSV-S

Partner Valve/High Quality Ball Valve LENO MSV-S Partner Valve/High Quality Ball Valve LENO MSV-S Description LENO MSV-S is a partner valve for all manual balancing valves in the LENO family. LENO MSV- S can also be applied as a high quality ball valve.

More information

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining

More information

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

Solar controllers Energy under control

Solar controllers Energy under control www.seltron.eu 2015 PROMATIC SGC Solar controllers Energy under control For domestic hot water. 14 PROMATIC SGC Solar controllers 15 PROMATIC SGC Solar controllers HIGHLIGHTS ycontrol of up to 65 different

More information

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic

More information

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Convertible radiator valve for one-pipe systems, centre distance 35 mm Convertible radiator valve for one-pipe systems, centre distance 35 mm 56 series ACCREDITED ISO 900 FM 65 033/6 GB Function 56 series convertible radiator valves are used on one-pipe radiator systems.

More information

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with

More information

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Multibox. Floor Heating Controller Flush individual room control for floor heating systems Multibox Floor Heating Controller Flush individual room control for floor heating systems IMI HEIMEIER / Floor Heating Control / Multibox Multibox K, RTL and K-RTL Multibox K, RTL and K-RTL is used for

More information

HERZ Differential Pressure Control Valve 4002

HERZ Differential Pressure Control Valve 4002 HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002

More information

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off Multibox 4 Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off IMI HEIMEIER / Floor Heating Control / Multibox 4 Multibox 4 RTL and K-RTL and K-RTL is

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure

More information

PROMATIC WDC Heating controllers Energy under control

PROMATIC WDC Heating controllers Energy under control www.seltron.eu 205 PROMATIC WDC Heating controllers Energy under control 36 Made for warmth. PROMATIC WDC Heating controllers 37 PROMATIC WDC Heating controllers HIGHLIGHTS ycontrol of up to 52 different

More information

Thermostatic mixing valves with interchangeable cartridges

Thermostatic mixing valves with interchangeable cartridges www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems

More information

Flush individual room control for floor heating systems

Flush individual room control for floor heating systems Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control

More information

Thermostatic mixing valves with replaceable cartridge for centralized systems

Thermostatic mixing valves with replaceable cartridge for centralized systems Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

Balancing & Control. Frese OPTIMIZER 6-way. Pressure Independent Control Group

Balancing & Control. Frese OPTIMIZER 6-way. Pressure Independent Control Group Balancing & Control Frese OPTIMIZER 6-way Pressure Independent Control Group Balancing & Control Frese OPTIMIZER 6-way Frese Innovative solutions from Frese balance global HVAC systems accurately and efficiently.

More information

Control valves for floor heating systems. Floor Heating Manifolds

Control valves for floor heating systems. Floor Heating Manifolds Control valves for floor heating systems Floor Heating Manifolds IMI HEIMEIER / Floor Heating Control / Control valves for floor heating systems Control valves for floor heating systems Supply control

More information

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

521 Series.  MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions MixCal adjustable three-way thermostatic mixing valve 37. www.caleffi.com Copyright 15 Caleffi 51 Series Installation, commissioning and service instructions Function The Caleffi MixCal three-way thermostatic

More information

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T www.caleffi.com 37. MixCal adjustable three-way thermostatic mixing valve Copyright Caleffi Installation, commissioning and servicing instructions Series Function The Caleffi MixCal three-way thermostatic

More information

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 INSTALLATION, COMMISSIONING AND OPERATING INSTRUCTIONS Contents Unit as delivered

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS INSTALLATION INSTRUCTIONS FOR CONTROL BOXES Pay attention to the total pressure loss when connecting UV4- to the control boxes for heating areas > 16 m²!

More information

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C. Anti-condensation circulation unit 8 series ACCREDITED ISO 9 F 654 ISO 9 No. CALEFFI 5/4 GB replaces dp 5/ Function The anti-condensation circulation unit performs the function of connecting the solid

More information

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

5231 Series.   Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341 NA31 www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 1 Caleffi Installation, commissioning and service instructions Function 531 Series ASSE 17 model 531 series high flow thermostatic

More information

Three-way reversing valve

Three-way reversing valve Three-way reversing valve For heating and cooling systems Pressurisation & Water Quality Balancing & Control thermostatic Control engineering avantage Three-way reversing valve for the distribution of

More information

Trade Product List 2013 BIOMASS ACCESSORIES

Trade Product List 2013 BIOMASS ACCESSORIES Trade Product List 2013 BIOMASS ACCESSORIES BIOMASS SYSTEM COMPONENTS Constant Temperature Control Accessories CONSTANT TEMPERATURE CONTROL PRODUCTS Order Code Description of Package and Contents Pictures

More information

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating FHM-Cx Mixing Shunts for Floor Heating Application Mixing shunt FHM-C5/C6 (UPS pump) The Danfoss compact mixing shunts are used for regulation of flow and supply temperature in hydronic floor heating systems.

More information

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

HEAT INTERFACE UNITS (Sanitary Hot Water Only) HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at

More information

Thermostatic valves with radiator connection systems

Thermostatic valves with radiator connection systems Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator

More information

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump Set point temperature regulating unit series ACCREDITED ISO 9 FM / GB replaces dp / GB Function The temperature regulating unit is made to be used in radiant panel systems, in combination with distribution

More information

Automatic balancing valves ASV-PV (new generation) DN 32-50

Automatic balancing valves ASV-PV (new generation) DN 32-50 Automatic balancing valves ASV-PV (new generation) DN 32-50 ASV-PV DN 32-50 Description ASV whiteboard animation SMT/SI ASV valves are automatic balancing valves. Together with Danfoss presetting radiator

More information

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50 Differential Pressure and Flow Meter Media 5 Indicator 160 Ø PN 50 Application Transmitter for measuring and indicating the differential pressure or measured variables derived from it Suitable for gases

More information

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge Regulux Description Separate presetting cone for consistent

More information

The solutions are here The choice is yours...

The solutions are here The choice is yours... Hydronic Balancing and Control The solutions are here The choice is yours... 1255 products to support your business The extended Hydronic Balancing and Control product range offers a solution for every

More information

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application: Data Sheet Compact Mixing Shunt for Floor Heating, FHM-Cx Application: FHM-C1 Mixing shunt FHM-C/ FHM-C Mixing shunt FHM-C Mixing shunt FHM-C The Danfoss floor heating compact mixing shunts are used for

More information

Akva Vita Instantaneous water heater

Akva Vita Instantaneous water heater Akva Vita Instantaneous water heater Akva Vita Table of Contents Akva Vita... 1 Table of Contents... 1 Safety notes... 2 Delivery... 2 Transport and storage... 2 Mounting... 3 Pipes connections... 4 Electrical

More information

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems Akva Vita TDP District heating flat station for direct heating and domestic hot water systems Akva Vita TDP Table of contents Akva Vita TDP... 1 Table of contents... 1 Safety notes... 2 Delivery... 2 Transport

More information

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting For reversed flow direction Thermostatic Radiator Valves Thermostatic valve body with and without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / For reversed flow direction For reversed

More information

RA 2000 Series RA 15/6T & TB Conversion Valve

RA 2000 Series RA 15/6T & TB Conversion Valve RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water

More information

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems Akva Vita TDP-F Table of contents Akva Vita TDP-F...1 Table of contents...1 Safety notes...2 Delivery...2

More information

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion

More information

Weather compensated flow temperature control of heating and boiler systems

Weather compensated flow temperature control of heating and boiler systems Instructions ECL Comfort 110 Application 130 Weather compensated flow temperature control of heating and boiler systems User guide, Installation & Maintenance DH-SMT/DK VI.KT.G3.02 Danfoss 06/2008 How

More information

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional. Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation

More information

manifold, for radiators

manifold, for radiators MMA, for radiators Eco-friendly materials, low lead content Quiet Precise and linear Dimension: DN 0 Temperature: C to + C Pressure class: PN 0 Description Area of use The Evoflow radiator is especially

More information

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA Thermostatic mixing valves with replaceable cartridge for centralized systems 3, 3 series CCREDITED ISO 9 FM ISO 9 No. 3 /3 N Replaces / N Function The thermostatic mixing valve is used in systems producing

More information

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602* User's Guide VI.7C.E6.02 2005.09 C37 *VI7CE602* *087R8070* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8070* *VI7CE602* Mixing controller with ON / OFF controlled

More information

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in

More information

Smart temperature control solutions

Smart temperature control solutions Smart temperature control solutions State-of-the-art heating and cooling solutions, expertise & know-how combined with top quality and superior customer service. 1 1 8 7 5 9 6 10 4 3 2 www.vexve.com Contents

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

5231 Series.  Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341. NA3. www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 5 Caleffi Installation, commissioning and service instructions Function 53 Series ASSE 7 model 53 series high fl ow thermostatic

More information

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating Data Sheet FHM-Cx Mixing Shunts for Floor Heating Application A self-acting proportional regulator is used to regulate the supply temperature. The regulator ensures that the desired supply temperature

More information

Components for solar heating systems

Components for solar heating systems solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised

More information

Standard. thermostatic valve body without presetting

Standard. thermostatic valve body without presetting Standard thermostatic valve body without presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEErInG advantage The standard thermostatic valve bodies are used in two-pipe

More information

FOR INSTALLING AND USING

FOR INSTALLING AND USING FOR INSTALLING AND USING Description and function The Solarmix thermostatic mixing valve is designed to reduce the water temperature to a safer level. Unlike the under basin, or bath/shower type valves

More information

THERMOSTATIC CONTROL TECHNOLOGY HORNE 40 AND 50 THERMOSTATIC MIXING SYSTEMS

THERMOSTATIC CONTROL TECHNOLOGY HORNE 40 AND 50 THERMOSTATIC MIXING SYSTEMS CONTROL TECHNOLOGY 40 AND 50 MIXING SYSTEMS 2 APPLICATIONS CONTROLLING TEMPERATURES IN; > hot water supplies distributed to groups of taps or showers. > domestic hot water supplies from large combination

More information

Thermostatic valve bodies

Thermostatic valve bodies Thermostatic valve bodies for single pipe heating systems Thermostatic valves with radiator connection systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Thermostatic valve bodies for single

More information

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems. AB-PM Consistent hydronic control Continuous energy savings AB-PM automatic balancing valve for a reliable and energy-saving heating system. 1 valve needed instead of 3 for pressure, flow and zone control

More information

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility Regulux Return Lockshield Radiator lockshield with consistent presetting and drain-off facility IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regulux Regulux The Regulux is used in warm water pump

More information

AVTI Multifunctional self - acting controller

AVTI Multifunctional self - acting controller AVTI Multifunctional self - acting controller Description / Application AVTI is a self - acting combined controller developed for controlling small heat units with a room heating system and a hot service

More information

ECL Comfort 110, application 130

ECL Comfort 110, application 130 Operating Guide ECL Comfort 110, application 130 (valid as of software version 1.08) English version www.danfoss.com How to navigate? Adjust temperatures and values. Switch between menu lines. Select /

More information

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control Thermostatic head K with contact or immersion sensor Thermostat-Köpfe For medium temperature control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K with contact or immersion

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

Mikrotherm. Manual Radiator Valves With presetting

Mikrotherm. Manual Radiator Valves With presetting Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,

More information

Paddle Flow Switch. Pressure Control Flow Switch

Paddle Flow Switch. Pressure Control Flow Switch Paddle Flow Switch GE-311 Plastic Paddle Flow Switch GE-312 Plastic Flow Switch GE-313 PETF Plastic Flow Switch GE-314 Stainless Steel Flow Switch GE-315 Adjustable Flow Switch GE-316 Brass Paddle Flow

More information

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves Vekotrim Valves for radiators with integrated valve Double connection fitting with shutoff ball valves for radiators with IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Vekotrim Vekotrim The Vekotrim

More information

Technical Product Guide

Technical Product Guide FMU - Floor Mixing Unit Boxed set pre-assembled for immediate installation: The FMU Floor Mixing Unit integrates both temperature and flow management, making the single piece unit very easy to install,

More information

Multilux 4-Eclipse-Set

Multilux 4-Eclipse-Set Multilux -Eclipse-Set Design-Edition with two-point connection, angle and straight type, for R / and connection, with automatic flow limitation IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Multilux

More information

prestige Control Application Supplement - ACVMax

prestige Control Application Supplement - ACVMax 2015-10 Prestige ACVMax Control Sup 12-14-15_ACVMax_Control 12/15/15 7:36 AM Page 1 prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory

More information

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface

More information

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA TankMixer water heater tank mixing valve 520 series CLEFFI 01267/17 N CCREDITED ISO 9001 FM 21654 ISO 9001 No. 000 Function The Caleffi TankMixer 520_X series kit combines a three-way thermostatic mixing

More information

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting Calypso exact Thermostatic Radiator Valves With stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Calypso exact Calypso exact thermostatic valve bodies are

More information

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise. Flush Individual Room Control for Floor Heating Systems To be precise. Contents Page Multibox K, Multibox RTL and Multibox K-RTL Description Construction Application 4 Temperature Setting 4 Function Article

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Prefabricated units / TA-COMFORT-S TA-COMFORT-S All in one design with differential pressure

More information

Control Application. Supplement - ACVMax

Control Application. Supplement - ACVMax prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

FSW300 Series Flow Switch

FSW300 Series Flow Switch . FSW300 Series Flow Switch - 2 - Series FSW300 Series FSW300 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.1.1 Reed contact - Switching of

More information

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting Calypso TRV-3 (for the Nordic countries) Thermostatic radiator valves With presetting IMI TA / Thermostatic heads and Radiator valves / Calypso TRV-3 (for the Nordic countries) Calypso TRV-3 (for the Nordic

More information

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function Anti-condensation recirculation and distribution unit 8 series ACCREDITED ISO 900 FM 654 ISO 900 No. 000 CALEFFI 04/4 GB Replaces dp 04/ GB GB Function The anti-condensation recirculation and distribution

More information

Signal anodes and sacrificial anodes. Rainwater harvesting. Domestic water system centre. Water filters

Signal anodes and sacrificial anodes. Rainwater harvesting. Domestic water system centre. Water filters Signal anodes and sacrificial anodes Rainwater harvesting Domestic water system centre Water filters CHAPTER Equipment for drinking water supply and rainwater harvesting OVERVIEW Equipment for drinking

More information

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control Thermostatic three-way valve body Thermostatic Radiator Valves without presetting, with automatic bypass control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic three-way valve body

More information

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1

More information

OEM Alpha Thermostat direct Analog

OEM Alpha Thermostat direct Analog OEM Alpha Thermostat direct Analog The OEM Alpha Thermostat direct Analog is a high-quality room thermostat in modern design for the registration and regulation of the desired room temperature, offering

More information

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems. 4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems. CT3101.0_00 EN June 2016 o o o o Valve with pre-adjustment; Variable centre

More information

MIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS

MIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS TCHNICAL SPCIFICATION DSCRIPTION Thermostatic mixing kit with micrometric valve with thermostatic option, circulation pump (rp Ready 641/2009/C - 622/2012/C), balancing lockshield and couple of manifolds

More information

DEVIATING VALVES ART K063

DEVIATING VALVES ART K063 FUNCTION The flow diverter valve Art.307 makes it possible to supply a branch circuit. Prepared to receive our electro-thermal controls Art. 978, 979, 980 or our thermostatic heads with remote sensor Art.

More information

Increase the attractiveness of your multi-family building

Increase the attractiveness of your multi-family building Modern heating technology for housing associations Increase the attractiveness of your multi-family building Energy-efficient and reliable heating solutions. Up to 23% energy savings thanks to intelligent

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS is a double differential thermostat used for domestic hot water heating. WITH DIFFERENTIAL THERMOSTAT ARE THREE POSSIBLE WAY OF USE: SYSTEM 1 (two sensors) Heating the domestic

More information

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS data sheet Danfoss prefabricated floorheatingunit Type FH-G/FH-GS//S Application The Danfoss prefabricated underfloorheating (UFH) unit for distribution of heating and domestic water is primarily designed

More information

Temperature controller for steam (PN 25) AVT / VGS - external thread

Temperature controller for steam (PN 25) AVT / VGS - external thread Data sheet Temperature controller for steam (PN 25) AVT / VGS - external thread Description The controller has a control valve VGS, thermostatic actuator and handle for temperature setting. Thermostatic

More information

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control

More information

CATALOGUE NUMBERS. Pressure Reducing Valve (PRV)** Mains Supply. Cold Water Outlets