TECHNICAL GUIDE MODELS: GM9T-UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

Size: px
Start display at page:

Download "TECHNICAL GUIDE MODELS: GM9T-UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE"

Transcription

1 TEHNIAL UIDE MODELS: M9T-UP AS-FIED ONDENSIN / HIH EFFIIENY UPFLOW TWO STAE FUNAES UP TO 94% AFUE NATUAL AS MBH INPUT EFFIIENY ATIN ETIFIED ISO 9001 ertified Quality Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at for the most up-to-date technical information. Additional rating information can be found at DESIPTION These ategory IV, highly efficient, compact, condensing type furnaces are designed for residential and commercial installations in a basement, closet, alcove, recreation room or garage where the ambient temperature is above 32 F, or higher. They may be either side wall or thru-roof vented using approved plastic type combustion air and vent piping. All units are factory assembled, wired and tested to assure dependable and economical installation and operation. WAANTY Lifetime limited warranty on both heat exchangers to the original purchaser; a 20-year limited warranty from original installation date to subsequent purchaser. 10-year warranty on the heat exchanger in commercial applications. 5-year limited parts warranty. FEATUES Two stage heating operation includes: - Two stage gas valve - Two stage inducer operation Provides increased comfort level & very quiet unit operation Adjustable delay timer allows two stage operation with single stage thermostat ompact, easy to install, ideal height 40" cabinet Blower-off delay for cooling SEE improvement. Easy to connect power/control wiring. Built-in, high level self diagnostics with fault code display. Low unit amp requirement for easy replacement application. Integrated control module for reliable, economical operation. May be installed as either two-pipe (sealed combustion) or single pipe vent (using indoor combustion air) Top intake & vent connection allows installation in narrow locations. Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. Induced combustion system with inshot main burners for quiet, efficient operation. No special vent termination kit required. 100% shut off main gas valve for extra safety. PS -four speed, direct drive motor with large, quiet blower. 24V, 40 VA control transformer and blower relay supplied for add-on cooling. Hi-tech tubular aluminized steel primary heat exchanger. Secondary (condensing) heat exchanger of 29-4 highgrade stainless steel. Timed on, adjustable off blower capability for maximum comfort. Solid removable bottom panel allows easy application. Easy access from front of unit for cleaning, maintenance or service. Protection from intake, exhaust or condensate blockage. Insulated blower compartment for quiet operation. FO DISTIBUTION USE ONLY - NOT TO BE USED AT POINT OF ETAIL SALE

2 A 1-1/2 AS PIPE ENTY 7/8 JUNTION BOX HOLE T-STAT WIIN 7/8 K.O. ONDENSATE DAIN 7/8 K.O /2 AS PIPE ENTY 7/8 JUNTION BOX HOLE OPTIONAL ETUN AI UT-OUT (either side) FO USE WITH EXTENAL FILTE FAME 13-7/8 T-STAT WIIN 7/8 K.O. ONDENSATE DAIN 7/8 K.O. 7/8 23-3/4 28-1/2 LEFT SIDE 7/8 26-3/4 FONT 1-1/2 1-1/4 24-3/8 5/8 20 5/8 IHT SIDE D B BOTTOM IMAE ETUN END /16 TOP IMAE SUPPLY END ABINET AND DUT DIMENSIONS Models Nominal abinet abinet Dimension FM Size A (in.) B (in.) (in.) D (in.) M9T040A12UP A 14-1/2 13-1/4 11-1/2 6-1/4 M9T060B12UP B 17-1/2 16-1/4 14-1/2 8-1/2 M9T080B12UP B 17-1/2 16-1/4 14-1/2 8-1/2 M9T08016UP / /8 M9T10016UP / /8 M9T10020UP / /8 M9T120D20UP D 24-1/2 23-1/4 21-1/2 10-5/8 2 Unitary Products roup

3 ELETIAL AND PEFOMANE DATA Input High/Low Output High/Low abinet Width * ESP (External Static Pressure).5" W is at furnace outlet ahead of cooling coil. Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical ode (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water. NOTES: 1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level. 2. Wire size based on copper conductors, 60, 3% voltage drop. 3. ontinuous return air temperature must not be below 55 F. 4. All filters must be high velocity cleanable type. 5. Air flows above 1800 FM require either return from two sides or one side plus bottom. Air Temp. ise Models Nominal Airflow* Total Unit AFUE MBH MBH FM In. Amps % F M9T040A12UP11 40/26 38/ / M9T060B12UP11 60/39 56/ / M9T080B12UP11 80/52 75/ / M9T08016UP11 80/52 75/ M9T10016UP11 100/65 93/ M9T10020UP11 100/65 93/ M9T120D20UP11 120/78 112/ / Input Max. Outlet Blower Blower Max. Min. Wire Size Operating Models High/Low Air Temp. Size Over-current 75 ft. Weight MBH F HP Amps In. Protect One Way Lbs. M9T040A12UP11 40/ / x M9T060B12UP11 60/ / x M9T080B12UP11 80/ / x M9T08016UP11 80/ / x M9T10016UP11 100/ / x M9T10020UP11 100/ x M9T120D20UP11 120/ x Unitary Products roup 3

4 BLOWE PEFOMANE FM Models M9T040A12UP11 M9T060B12UP11 M9T080B12UP11 M9T08016UP11 M9T10016UP11 M9T10020UP11 M9T120D20UP11 Models M9T10020UP11 M9T120D20UP11 Speed Tap Airflow with Bottom or One Side etrun - without Filters (FM) External Static Pressure, Inches W High N N Med-High N N Med-Low N N N Low N N N High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low Airflow with Two Side eturns or with Bottom and One Side eturn - without Filters Speed Tap External Static Pressure, Inches W High Med-High Med-Low Low High Med-High Med-Low Low NOTES: 1. Airflow expressed in standard cubic feet per minute (FM). 2. eturn air is through side opposite motor (left side). 3. In order to stay within the velocity rating of the filters, airflows above 1800 FM require either return from two sides or one side plus bottom. 4. Motor voltage at 115 V. 5. N = Operation at this static pressure is not recommended. 4 Unitary Products roup

5 FILTE PEFOMANE The airflow capacity data published in the Blower Performance table listed above represents blower performance WITHOUT filters. To determine the approximate blower performance of the system, apply the filter drop value for the filter being used or select an appropriate value from the Filter Performance table shown below. NOTE: The filter pressure drop values in the Filter Performance table shown below are typical values for the type of filter listed and should only be used as a guideline. Actual pressure drop ratings for each filter type vary between filter manufacturer. EOMMENDED FILTE SIZES Input/Output BTU/H FM abinet Size Side eturn Filter in. Bottom eturn Filter in. 40/ A 16 x x 25 60/ B 16 x x 25 80/ B 16 x x 25 80/ x x / x x / x x / D (2) 16 x x 25 NOTES: 1. Air velocity through throwaway type filters may not exceed 300 feet per minute. All velocities over this require the use of high velocity filters. 2. Air flows above 1800 FM require either return from two sides or one side plus bottom. FILTE PEFOMANE - PESSUE DOP INHES W.. AND (KPA) Airflow ange Minimum Filter Type Opening Size Disposable Washable Fiber Pleated FM in 2 In W.. In W.. In W & Above UNIT LEAANES TO OMBUSTIBLES Top Front ear Left Side ight Side Flue Floor/ loset Application Attic In. In. In. In. In. In. Bottom Alcove Upflow ombustible Yes Yes Unitary Products roup 5

6 For additional connection diagrams for all UP equipment refer to Low Voltage System Wiring document available online at in the Product atalog Section. A9 2 Stage Scroll A/ w/2 Stage Furnace, 2 Stage ooling eady- PT8/9; (F,L)*8/9T, (,L)*8/9T, XY8S-*, XYF8S-*, XY9S-*, XYF9S-* *DN22U Volt ommon Y First Stage ool Second Stage ool (Heat XFM) (ool XFM) *PP32U Volt ommon Y First Stage ool Second Stage ool (Heat XFM) (ool XFM) *DN *DP22U70124 *PP32U Volt ommon Y First Stage ool Second Stage ool W 24-Volt ommon First Stage ool Second Stage ool *PP32U Volt ommon First Stage ool Second Stage ool L HM Humidistat onnection of the "" Termainal, 24-Volt ommon, is optional when used with batteries onnection of the "" Termainal, 24-Volt ommon, is optional when used with batteries onnection of the "" Termainal, 24-Volt ommon, is optional when used with batteries onnection of the "" Termainal, 24-Volt ommon, is optional when used with batteries Step 1 of Thermostat User onfiguration Menu must be set to MLTI ST Thermostat Installer Setup Number 1 - System Type - must be set to 6-2 Heat/2 ool onventional Thermostat Installer Setup Number System Type - must be set to 8-2 Heat/2 ool Multistage onventional Step 1 of Thermostat User onfiguration Menu must be set to MS 2 Step 16 of Thermostat User onfiguration Menu must be set to ON to use omfort Alert Features Thermostat Installer Setup Number 15 - ompressor Protection - must be set to 5 2 STAE PS FUNAE ONTOL 24-Volt ommon First Stage ool Y/ Single/Second Stage ool W/W1 Single/ TWO STAE AI ONDITIONIN 24-Volt ommon First Stage ool Second Stage ool omfort Alert Interface 24V HUMIDIFIE (Optional) FIUE 1: Thermostat hart - A 6 Unitary Products roup

7 HP23 Two Stage H/P - H*5B, YZE - w/two Stage Furnace, 2 Stage ooling eady - PT8/9, (F,L)*8/9T, (,L)*8/9T, XY8S-*, XYF8S-*, XY9S-*, XYF9S-* W/ Series Demand ontrol; Hot Heat Pump Mode O onventional PS-2 STAE *PP32U70124 *DN22H00124 *PP32U71124 OOLIN EADY *DP22U70124 *PP32U72124 FUNAE ONTOL 24-Volt ommon Y /ool (ool XFM) (Heat XFM) E Emergency Heat O/B eversing Valve L /ool AUX Auxiliary Heat 24-Volt ommon /ool O eversing Valve Energized in ool L /ool First Stage Auxiliary Heat Second Stage Auxiliary Heat 24-Volt ommon /ool DHM Dehumidistat O eversing Valve Energized in ool L /ool First Stage Auxiliary Heat Second Stage Auxiliary Heat HM Humidistat 24-Volt ommon First Stage ool Y/ Single/Second Stage ool W/W1 Single/ Bonnet Sensor (Optional) 24V HUMIDIFIE (Optional) Thermostat Installer Setup Number System Type - must be set to 12-3 Heat/2 ool Heat Pump Selection of AS/ELE switch on thermostat not necessary Step 1 of Thermostat User onfiguration Menu must be set to Heat Pump 2 Set Delay on furnace to OFF Thermostat Installer Setup Number eversing Valve (O/B) Operation - must be set to 0 - O/B Terminal Energized in ooling Step 1 of Thermostat User onfiguration Menu must be set to Heat Pump 2 Thermostat Installer Setup Number Backup Heat Source - must be set to 1 - Heat Pump Backup Heat Source is Fossil Fuel Thermostat Installer Setup Number External Fossil Fuel Kit - must be set to 0 - External Fossil Fuel Kit is ontrolling Heat Pump Backup Heat TWO STAE HEAT PUMP 24-Volt ommon /ool OUT Second Stage ool Output W1 OUT First Stage Auxiliary Heat Output OUT Second Stage Auxiliary Heat Output O eversing Valve Energized in ool X/L /ool W Auxiliary Heat BS Bonnet Sensor BS Bonnet Sensor hange FFuel Jumper on Heat Pump to ON FIUE 2: Thermostat hart - HP Unitary Products roup 7

8 APPLYIN FILTE PESSUE DOP TO DETEMINE SYSTEM AIFLOW To determine the approximate airflow of the unit with a filter in place, follow the steps below: 1. Select the filter type. 2. Select the number of return air openings or calculate the return opening size in square inches to determine the proper filter pressure drop. 3. Determine the External System Static Pressure (ESP) without the filter. 4. Select a filter pressure drop from the table based upon the number of return air openings or return air opening size and add to the ESP from Step 3 to determine the total system static. 5. If total system static matches a ESP value in the airflow table (i.e. 0.20, 0.60, etc,) the system airflow corresponds to the intersection of the ESP column and Model/ Blower Speed row. 6. If the total system static falls between ESP values in the table (i.e. 0.58, 0.75, etc.), the static pressure may be rounded to the nearest value in the table determining the airflow using Step 5 or calculate the airflow by using the following example. Example: For a 120,000 Btuh furnace with 2 return openings and operating on high speed blower, it is found that total system static is 0.58" w.c. To determine the system airflow, complete the following steps: 1. Obtain the airflow values at 0.50" & 0.60" ESP. 0.50": 2285 FM 0.60": 2175 FM 2. Subtract the 0.50" from the 0.60" to obtain airflow difference = -110 FM 3. Subtract the total system static from 0.50" and divide this difference by the difference in ESP values in the table, 0.60" ", to obtain a percentage. ( ) / ( ) = Multiply percentage by airflow difference to obtain airflow reduction. (0.8) x (-110) = Subtract airflow reduction value to 0.50" to obtain actual 0.58" ESP = 2197 AESSOIES ONENTI VENT TEMINATION - 1T0302 (2") 1T0303 (3") For use through rooftop, sidewall. Allows combustion air to enter and exhaust to exit through single common hole. POPANE (LP) ONVESION KIT - 1NP All units This accessory conversion kit may be used to convert natural gas units for propane (LP) operation. onversions must be made by qualified distributor or dealer personnel. ONDENSATE NEUTALIZE KIT - 1NK0301 Neutralizer cartidge has a 1/2" plastic tube fittings for installation in the drain line. alcium carbonate refill media is also available from the Source 1 Parts (p/n ). SIDEWALL VENT TEMINATION KIT - 1HT0901 (3") 1HT0902 (2") For use on sidewall, two-pipe installations only. Provide a more attractive termination for locations where the terminal is visable on the side of the home. EXTENAL SIDE ETUN FILTE AK - 1SF Fits all cabinet sizes Attaches to side of furnace cabinet in side return applications. Holds any 16x25x1 permanent or disposable filter. SIDE ETUN FILTE AK- 1S All Models 1S All Models BOTTOM ETUN FILTE AK- 1B0114 or 1B For 14-1/2 cabinets 1B0117 or 1B For 17-1/2 cabinets 1B0121 or 1B For 21 cabinets 1B0124 or 1B For 24-1/2 cabinets HIH ALTITUDE PESSUE SWITHES - For installation where the altitude is less than 8,000 feet it is not required that the pressure switch be changed. For altitudes above 8,000 feet see kits below. onversion must be made by qualified distributor or dealer personnel. 1PS MBH 1PS /1200 MBH 1PS /1600, 100/1600, 120 MBH 1PS /2000 MBH 1PS MBH OOM S - A wide selection of compatible thermosets are available to provide optimum performance and features for any installation. 1H/1, manual change-over electronic non-programmable thermostat. 1H/1, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat. 1H/1, auto/manual changeover, electronic programmable. * For the most current accessory information, refer to the price book or consult factory. Subject to change without notice. Printed in U.S.A. opyright by York International orp All rights reserved. Supersedes: BT-B-0806 Unitary 5005 Norman Products York OK roup Drive 73069

TECHNICAL GUIDE. Echelon MODELS: FC9T GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

TECHNICAL GUIDE. Echelon MODELS: FC9T GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE TEHNIAL UIDE Echelon MODELS: F9T AS-FIED ONDENSIN / HIH EFFIIENY UPFLOW TWO STAE FUNAES UP TO 94% AFUE NATUAL AS 40-120 MBH INPUT EFFIIENY ATIN ETIFIED Due to continuous product improvement, specifications

More information

TECHNICAL GUIDE MODELS: GY9F*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 95% AFUE DESCRIPTION WARRANTY FEATURES YTG-B-0907

TECHNICAL GUIDE MODELS: GY9F*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 95% AFUE DESCRIPTION WARRANTY FEATURES YTG-B-0907 TEHNIAL UIDE MODELS: 9F*UP AS-FIED ONDENSIN / HIH EFFIIEN UPFLO FUNAES 95% AFUE NATUAL AS 48-96 MBH INPUT EFFIIEN ATIN ETIFIED ISO 9001 ertified Quality Management System DESIPTION These ategory IV, highly

More information

TECHNICAL GUIDE AFFINITY MODELS: PS9*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% TO 94% AFUE

TECHNICAL GUIDE AFFINITY MODELS: PS9*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% TO 94% AFUE TEHNIAL UIDE AFFINIT MODELS: PS9*UP AS-FIED ONDENSIN / HIH EFFIIEN UPFLO SINLE STAE FUNAES 92% TO 94% AFUE NATUAL AS 40-135 MBH INPUT EFFIIEN ATIN ETIFIED ISO 9001 ertified Quality Management System Due

More information

TECHNICAL GUIDE MODELS: GM9S*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92% TO 94% AFUE DESCRIPTION WARRANTY FEATURES BTG-A-0407

TECHNICAL GUIDE MODELS: GM9S*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92% TO 94% AFUE DESCRIPTION WARRANTY FEATURES BTG-A-0407 TEHNIAL UIDE MODELS: M9S*UP AS-FIED ONDENSIN / HIH EFFIIEN UPFLO FUNAES 92% TO 94% AFUE NATUAL AS 40-135 MBH INPUT EFFIIEN ATIN ETIFIED ISO 9001 ertified Quality Management System DESIPTION These ategory

More information

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE TEHNIAL GUIDE Acclimate MODELS: FL9S GAS-FIRED ONDENSING / HIGH EFFIIENY UPFLOW SINGLE STAGE FURNAES 92% AFUE NATURAL GAS 40-135 MBH INPUT EFFIIENY RATING ERTIFIED ISO 9001 ertified Quality Management

More information

TECHNICAL GUIDE. AFFINITY MODELS: PS8*DH GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW/HORIZONTAL FURNACES STANDARD & Low NOx DESCRIPTION WARRANTY

TECHNICAL GUIDE. AFFINITY MODELS: PS8*DH GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW/HORIZONTAL FURNACES STANDARD & Low NOx DESCRIPTION WARRANTY TEHNIAL UIDE AFFINIT MODELS: PS8*DH AS-FIED HIH EFFIIEN SINLE STAE DONFLO/HOIZONTAL FUNAES STANDAD & Low NOx NATUAL AS 40-130 MBH INPUT EFFIIEN ATIN ETIFIED DESIPTION These high efficiency, downflow/horizontal

More information

TECHNICAL GUIDE. Echelon MODELS: FC9M*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW MODULATING FURNACES

TECHNICAL GUIDE. Echelon MODELS: FC9M*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW MODULATING FURNACES TEHNIAL UIDE Echelon MODELS: F9M*UP AS-FIED ONDENSIN / HIH EFFIIEN UPFLO MODULATIN FUNAES NATUAL AS 60-0 MBH INPUT EFFIIEN ATIN ETIFIED ISO 900 ertified Quality Management System Due to continuous product

More information

TECHNICAL GUIDE MODELS: GM9S*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW/HORIZONTAL FURNACES 92% TO 94% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: GM9S*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW/HORIZONTAL FURNACES 92% TO 94% AFUE DESCRIPTION WARRANTY FEATURES TEHNIAL UIDE MODELS: M9S*DH AS-FIED ONDENSIN / HIH EFFIIEN DONFLO/HOIZONTAL FUNAES 92% TO 94% AFUE NATUAL AS 40-120 MBH INPUT EFFIIEN ATIN ETIFIED ISO 9001 ertified Quality Management System 278177-BT-A-0407

More information

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev. 036-1349-001 Rev. A (30) Heating TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 9 AFUE NATURAL GAS 37-130 MBH OUTPUT Air Conditioning EFFICIENCY RATING CERTIFIED R

More information

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES 036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING

More information

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S NATURAL GAS 60-120 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

INSTALLATION MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES. MODELS: PC9*UP, FC9C*UP, FL9C*UP (Modulating Upflow with ECM Motor)

INSTALLATION MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES. MODELS: PC9*UP, FC9C*UP, FL9C*UP (Modulating Upflow with ECM Motor) INSTALLATION MANUAL HIGH EFFIIENY TUBULA HEAT EXHANGE SEIES MODELS: P9*UP, F9*UP, FL9*UP (Modulating Upflow with EM Motor) 60-120 MBH INPUT (17.6-35.2 KW) INPUT EFFIIENY ATING ETIFIED ISO 9001 ertified

More information

INSTALLATION MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES. MODELS: PV9*UP / FC9V*UP / FL9V*UP (Two Stage Variable Speed Upflow)

INSTALLATION MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES. MODELS: PV9*UP / FC9V*UP / FL9V*UP (Two Stage Variable Speed Upflow) INSTALLATION MANUAL HIGH EFFIIENY TUBULAR HEAT EXHANGER SERIES MODELS: PV9*UP / F9V*UP / FL9V*UP (Two Stage Variable Speed Upflow) 40-120 MBH INPUT (11.7-35.1 KW) INPUT EFFIIENY RATING ERTIFIED ISO 9001

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409 TEHNIAL UIDE SINLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SSTEM OOLIN & HEAT PUMPS MODELS: F6FP018-060 DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal

More information

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C) TEHNIAL UIDE SINLE PIEE VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLIN & HEAT PUMPS MODELS: AV24 THRU 60*() DESRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal application. These versatile models may be used for split-system cooling or heat pump operation. ompact

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency

More information

G6RC Series TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS G6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency upfl

More information

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S

More information

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES FORM NO. G11-489 REV. 2 Supersedes Form No. G11-489 Rev. 1 GAS FURNACES RGPR- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single Phase [15 to 37 kw] (U.S.

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH FORM NO. G11-508 Supersedes Form No. G11-508 GAS FURNACES RGLE- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models)

More information

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES FORM NO. GSC-493 REV. 3 Supersedes Form No. GSC-493 Rev. 2 GF902U*B SERIES Models with Input Rates of 45,000, 60,000, 75,000, 90,000 & 105,000 BTU/HR [13.19, 17.58, 22, 26.38 & 30.77 kw] 90 PLUS WITH DUAL

More information

5.0 AIR HANDLER EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM INTERFACE BOARD

5.0 AIR HANDLER EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM INTERFACE BOARD 5.0 AI HANDLE EQUIPPED WITH THE OMFOT ONTOL 2 SYSTEM INTEFAE BOAD FIGUE 8 THE AI HANDLE OMFOT ONTOL 2 SYSTEM ONTOL BOAD The HPN-series of air handlers are designed to operate with conventional 24VA controls

More information

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE). This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency

More information

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G22-473 REV. 3 Supersedes Form No. G22-473 Rev. 2 GAS FURNACES UGPL- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR [15 to 37 kw] (U.S. & Canadian Models) Annual Fuel

More information

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-490 GAS FURNACES RGLR- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

FG7T (C and L Series)

FG7T (C and L Series) TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The

More information

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE

More information

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above) FORM NO. G22-482 REV. 8 Supersedes Form No. G22-482 Rev. 7 GAS FURNACES RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above) 90 PLUS WITH DUAL COMFORT CONTROL

More information

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. G66-477 Supersedes Form No. A11-152 Rev. 3 90 EFFICIENCY UPF GAS FURNACES 90RJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above)

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart M1200 Product Line Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.1 AFUE Input 60,000-120,000

More information

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL FORM NO. G11-499 Supersedes Form No. G11-499 GAS FURNACES RGFE- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kw] (All Models 92% A.F.U.E. or Above) Equipped with Comfort

More information

INSTALLATION MANUAL MODULAR VARIABLE SPEED AIR HANDLERS MODELS: MV LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL MODULAR VARIABLE SPEED AIR HANDLERS MODELS: MV LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL MODULA VAIABLE SPEED AI HANDLES MODELS: MV ISO 9001 ertified Quality Management System GENEAL.............................................. 1 SAFETY................................................

More information

Energy Saving. Space Saving.

Energy Saving. Space Saving. Energy Saving. Space Saving. An Unbeatable Combination! 92% Gas Furnace Comfort, efficiency, and dependability make an unbeatable combination in the 92% gas furnace! Energy Savings Two heat exchangers

More information

395CAV Sizes 045 thru 155 Series H and J

395CAV Sizes 045 thru 155 Series H and J ENERGY-EFFICIENT INDUCED-COMBUSTION DELUXE UPFLOW FURNACE 395CAV Sizes 045 thru 155 Series H and J With a unique approach to induced-combustion design, a 40-in. tall cabinet, 4-pass heat exchanger, an

More information

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...

More information

5.0 AIR HANDLER Comfort Control 2 System INTERFACE BOARD

5.0 AIR HANDLER Comfort Control 2 System INTERFACE BOARD 5.0 AI HANDLE omfort ontrol 2 System INTEFAE OAD FIGUE 8 THE AI HANDLE ONTOL OAD EQUIPPED WITH THE omfort ontrol 2 System The HPL-series of air handlers are designed to operate with conventional 24VA controls

More information

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2 System RGLE- Series 80% A.F.U.E. Input Rates 75-125 kbtu ENER

More information

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. GSC-497 REV. 2 Supersedes Form No. GSC-497 Rev. 1 GF901U SERIES Models with Input Rates 45,000, 60,000, 105,000 & 120,000 BTU/HR [13.19, 17.58, 30.77, & 35.17 kw] (All Models 90% A.F.U.E. or Above)

More information

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G66-452 REV. 3 Supersedes Form No. G66-452 Rev. 2 GAS FURNACES WGTA- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (U.S. & Canadian Models) (All Models 90% A.F.U.E.

More information

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above) FORM NO. G66-480 Supersedes Form No. G66-480 Rev. 0 90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/ HORIZONTAL

More information

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR FORM NO. G22-506 Supersedes Form No. G22-506 Rev. 1 GAS FURNACES RGLT- SERIES Models with Input Rates from 75,000 to 125,000 BTU/HR [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization Efficiency

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL

More information

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. G11-503 REV. 1 Supersedes Form No. G11-503 GAS FURNACES Visit www.rheem.com for complete details. RGRC- SERIES Model with Input Rates from 45,000 to 105,000 BTU/HR [13.19 to 30.77 kw] (All Models

More information

T9MPV SmartComfort VS90 Product Specifications

T9MPV SmartComfort VS90 Product Specifications 90+ Variable Speed Two -Stage Heating Furnace FLEXIBILITY Supports two--stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40 high with wider cabinets, for ease of installation

More information

GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A)

GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A) GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A) HVAC SERVICE PARTS Supersedes: 035-20642-001 Rev. A (0904) 035-20642-001 Rev. B (0205) 1 of 8 Figure 1: UPFLOW 2-STAGE VARIABLE

More information

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006) T9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 4 high with wider cabinets, for ease of installation. Factory shipped as natural gas, with LP Gas conversion

More information

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Rheem Classic Series Downflow/ Horizontal Gas Furnaces Gas Furnaces Rheem Classic Series Downflow/ Horizontal Gas Furnaces RGTC- Series Up to 95% A.F.U.E. Input Rates from 45 to 105 kbtu [13.19 to 30.77 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Ruud Acheiver Series Upflow Gas Furnaces

Ruud Acheiver Series Upflow Gas Furnaces Gas Furnaces Ruud Acheiver Series Upflow Gas Furnaces RGRC- Series 95% A.F.U.E. Input Rates from 45 to 105 kbtu [13.19 to 30.77 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY INSTALLATION MANUAL ESIDENTIAL AS FUNAE WITH PS MOTO MODELS: TM8M/TMLM*MP, YM8M/YMLM*MP, M8M/MLM*MP, LM8M/LMLM*MP (80% Modulating Multi-position / Low NOx) EFFIIENY ATIN ETIFIED ISO 9001 ertified Quality

More information

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL 25--21--65 Representative photo only, some models may vary in appearance. MANUFACTURED FOR NATURAL GAS CONVERTIBLE TO (LP) PROPANE GAS NOTE: These

More information

2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR

2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR 07.2009 Page: 117 Furnaces 97+% Gas Furnace Acclimate Series LXLP9C060B12MP11 * 97.5% MODULATING 60,000 BTU 1200 CFM MULTI-POSITION GAS FURNACE $3,780.47 LXLP9C080B12MP11 * 97.5% MODULATING 80,000 BTU

More information

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System Gas Furnaces Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2 System RGJF- Series Up to 94.8% A.F.U.E. Input Rates from 60 to 120 kbtu [17.58 to 35.16 kw] With

More information

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND FORM NO. G11-500 REV. 1 Supersedes Form No. G11-500 GAS FURNACES RGGE- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kw] (U.S. & Canadian Models) Equipped with Comfort Control

More information

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications ENGINEERING DATA Typical Applications G20RE and G20RXE WhisperHeat DOWN-FLO GAS FURNACES *78.0% A.F.U.E. 50,000 to 150,000 Btuh Input Add-On Cooling 2 thru 5 Nominal Tons *Isolated Combustion System rating

More information

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h Series 80% AFUE Multi-Position, Dual$aver Multi-Speed Gas Furnace Heating Input: 70,000 115,000 BTU/h Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve that allows installer to

More information

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E. FORM NO. G11-468 REV. 13 Supersedes Form No. G11-468 Rev. 12 GAS FURNACES RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kw] (All Models 92% A.F.U.E. or Above) Modulating

More information

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES FORM NO. G11-493 REV. 5 Supersedes Form No. G11-493 Rev. 4 GAS FURNACES RGRL- SERIES Models with Input Rates of 45,000, 60,000, 75,000 & 90,000 BTU/HR [13.19, 17.58, 22, & 26.38 kw] 90 PLUS WITH DUAL COMFORT

More information

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. GSC-534 GF901U SERIES Models with Input Rates 45, 60, 75, 90, 105 & 120 kbtu [13.19, 17.58, 21.9, 26.4, 30.77 & 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY UPFLOW GAS FURNACES The

More information

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage onvertible, Multi-Speed EM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h ontents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagrams...

More information

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-452 REV. 10 Supersedes Form No. G11-452 Rev. 9 GAS FURNACES RGTA- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) CLASSIC

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h 80% AFUE Multi-Position, TwinComfort Multi-Speed Gas Furnace Heating Input: 60,000 100,000 BTU/h Standard Features Patented dual-diameter tubular heat exchanger Two-stage gas valve that allows installer

More information

GAS FURNACES II 78% A.F.U.E. UPFLOW GAS FURNACES CRITERION

GAS FURNACES II 78% A.F.U.E. UPFLOW GAS FURNACES CRITERION FORM NO. G11-442 REV. 6 Supersedes Form No. G11-442 Rev. 5 GAS FURNACES RGDG- SERIES Standing Pilot Models with Input Rates from 45,000 to 150,000 BTU/HR [13 to 44 kw] (U.S. & Canadian Models) ENER UIDE

More information

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Data... Wiring Diagrams... 0

More information

8+* Bulletin No November 1997

8+* Bulletin No November 1997 ENGINEERING DATA VALUE 80Z UP-FLOW/HORIZONTAL GAS FURNACES *80.0 to 80.5% A.F.U.E. 45,000 to 20,000 Btuh (3.2 to 32.2 kw) Input Heating Capacity -/2 thru 6 Tons (3.5 thru 2. kw) Nominal Add-on Cooling

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

G34M Bulletin #69/ August 2003

G34M Bulletin #69/ August 2003 ENGINEERING DATA G34M MULTI POSITION GAS FURNACE 12.4 to 31.0 kw Output 52.7 to 131.9 Mj Input 3.5 to 17.6 kw Nominal Add-on Cooling GAS FURNACES 50 Hz G34M Bulletin #69/490045 August 2003 Typical Applications

More information

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. G11-450 REV. 13 Supersedes Form No. G11-450 Rev. 12 GAS FURNACES /RGRB- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) CLASSIC

More information

INSTALLATION MANUAL TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-B-0806

INSTALLATION MANUAL TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-B-0806 INSTALLATION MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: PT9 / FC9T / FL9T (Two Stage Downflow/Horizontal) 60-120 MBH INPUT (17.62-35.17 KW) INPUT EFFICIENCY RATING CERTIFIED ISO 9001

More information

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa) 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling

More information

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E. FORM NO. G11-468 REV. 15 Supersedes Form No. G11-468 Rev. 14 GAS FURNACES Visit www.rheemac.com/ taxcredit for complete details. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58

More information

MX Series Indoor Modular Blowers ModuleFlex Electric or Hot Water Heat with available Variable-Speed High Efficiency ECM Motor

MX Series Indoor Modular Blowers ModuleFlex Electric or Hot Water Heat with available Variable-Speed High Efficiency ECM Motor IM-MAH-0662403-11 November 2017 Installation Instructions MX Series Indoor Modular Blowers ModuleFlex Electric or Hot Water Heat with available Variable-Speed High Efficiency EM Motor TABLE OF ONTENTS

More information

ZONE PANEL KIT INSTALLATION MANUAL COMMUNICATING ZONE PANEL KIT - (S1-TCZCB01A) ZONE PANEL WITH ZONING TOUCH SCREEN FIRMWARE

ZONE PANEL KIT INSTALLATION MANUAL COMMUNICATING ZONE PANEL KIT - (S1-TCZCB01A) ZONE PANEL WITH ZONING TOUCH SCREEN FIRMWARE ZONE PANEL KIT INSTALLATION MANUAL OMMUNIATING ZONE PANEL KIT - (S1-TZB01A) ZONE PANEL WITH ZONING TOUH SEEN FIMWAE FO USE WITH TOUH SEEN OMMUNIATING ONTOL MODELS: S1-TTS GENEAL INFOMATION This kit is

More information

INSTALLATION MANUAL RESIDENTIAL GAS FURNACE MODELS TM8V*MP, TMLV*MP 80% AFUE. (Two Stage ECM Multi-position / Low NOx) LIST OF SECTIONS

INSTALLATION MANUAL RESIDENTIAL GAS FURNACE MODELS TM8V*MP, TMLV*MP 80% AFUE. (Two Stage ECM Multi-position / Low NOx) LIST OF SECTIONS INSTALLATION MANUAL ESIDENTIAL GAS FUNAE MODELS TM8V*MP, TMLV*MP 80% AFUE (Two Stage EM Multi-position / Low NOx) EFFIIENY ATING ETIFIED ISO 9001 ertified Quality Management System SAFETY...............................................

More information

Comfort, Quality and Efficiency.

Comfort, Quality and Efficiency. Comfort, Quality and Efficiency. An Unbeatable Combination! 80% Gas Furnace This low profile gas furnace stands tall in features and fuel economy Models are available in upflow/horizontal and downflow

More information

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS Service Literature orp. 1501-L2 August 2016 Revised March 2017 LRP14HP/DF/A/GE LRP16GE/HP 2 to 5 Ton (7.0 to 17.6 kw) LRP14HP/LRP14DF/LRP14A/LRP14GE/LRP16GE/LRP16HP SERIES UNITS The LRP14/16 series packaged

More information

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004) H9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe). Direct Vent Furnace 4 high with wider cabinets, for noise reduction and ease of installation. Factory shipped as natural

More information

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. G11-497 REV. 4 Supersedes Form No. G11-497 Rev. 3 RGRS/RGRT- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY UPF

More information

ELITE SERIES Downflow - High Efficiency Blower Motor

ELITE SERIES Downflow - High Efficiency Blower Motor PRODUCT SPECIFICATIONS GAS FURNACES EL80DFE ELITE SERIES Downflow - High Efficiency Blower Motor Bulletin No. 2066 July 208 Supersedes February 208 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on

More information

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D1ACV52A TUD2D140ACV52A TDD2B060ACV32A TDD2B080ACV32A TDD2C100ACV52A

More information

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h ADSH8 Heating Input: 40,000 100,000 BTU/h Two-Stage Convertible Multi-Speed Gas Furnace 80% AFUE Standard Features Two-stage convertible gas valve automatically adjusts to high or low stage Durable SureStart

More information

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower PRODUCT SPECIFICATIONS OIL FURNACES sl085bv DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower Bulletin No. 0677 August 05 Supersedes September 04 AFUE - Up to 87% Heating Input - 79,000 to

More information

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. ) FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features

More information

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S SL280DFV DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Blower Bulletin No. 20576 December 200 Supersedes July 200

More information

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-498 REV. 5 Supersedes Form No. G11-498 Rev. 4 RGTS- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/

More information

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-538 Supersedes Form No. GTZ-503 Rev. 1 TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 95% A.F.U.E. ) 95% A.F.U.E. MULTI POSITION GAS FURNACES Features

More information

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. ) FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential

More information

R-410A AFFINITY SERIES

R-410A AFFINITY SERIES -0A AFFINITY SEIES DNZ0-060 -5 Ton eneral.......................................... Installation........................................ Limitations.................................... Location........................................

More information

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX060, 080, 100, 120R TDX060, 080, 100, 120R Direct Vent with Variable Speed Inducer PUB. NO. 22-1705-02-1202

More information

80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-496 REV. 4 Supersedes Form No. G11-496 Rev. 3 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The

More information

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G22-498 Supersedes Form No. P66-765 Rev. 3 90TS- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/ HORIZONTAL

More information

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information