SEPARATION AND CONSTRUCTION REQUIREMENTS FOR SEWER AND WATER LINES (PARALLEL)
|
|
- Simon Davis
- 5 years ago
- Views:
Transcription
1 SEPARATION AND CONSTRUCTION REQUIREMENTS FOR SEWER AND WATER LINES (PARALLEL) W-1/S-3
2 SEPARATION AND CONSTRUCTION REQUIREMENTS FOR SEWER AND WATER LINES (CROSSINGS) W-2/S-4
3 TYPICAL TRENCH BACKFILL DETAILS W-3
4 TYPICAL LOCATION OF WATER METER BOX W-5A
5 TYPICAL LOCATION OF WATER METER BOX W-5B
6 DETAIL OF 1" SERVICE CONNECTION AND METER INSTALLATION W-7
7 DETAIL OF 1-1/2" SERVICE CONNECTION AND METER INSTALLATION W-9
8 DETAIL OF 2" SERVICE CONNECTION AND METER INSTALLATION W-11
9 DETAIL OF DUCTILE IRON METER MANIFOLD ASSEMBLY W-13B
10 u u u u u DIMENSIONS FOR FABRICATED STEEL FITTINGS (ALL DIMENSIONS IN INCHES) W-14
11 (760) 398-xxxx 10' OFFSET P C I A w P U A E T T L I E I O R N N E CALL BEFORE DIGGING CVWD A V DETAIL OF DOMESTIC WATER VALVE OPERATOR WELL INSTALLATION W-17
12 DETAIL OF DOMESTIC WATER VALVE OPERATOR WELL CAP AND FRAME W-18
13 DETAIL OF CONCRETE THRUST BLOCKS W-19/S-19
14 THRUST BLOCK BEARING AREAS W-20/S-20
15 1" AUTOMATIC COMBINATION AIR RELEASE & AIR/VACUUM VALVE INSTALLATIONS W-21A
16 2" AUTOMATIC COMBINATION AIR RELEASE & AIR VACUUM VALVE INSTALLATIONS W-21B
17 4" AND LARGER AUTOMATIC COMBINATION AIR RELEASE & AIR/VACUUM VALVE INSTALLATION W-21C
18 1" AND 2" AIR & VACUUM VALVE ENCLOSURE LOCATIONS W-22A
19 ALTERNATIVE 1" AND 2" AIR & VACUUM VALVE ENCLOSURE LOCATIONS W-22B
20 AIR RELEASE & AIR/VACUUM INSTALLATION LOCATIONS AT SIPHONS W-22C
21 DETAIL OF 4" OR 6" BLOWOFF ASSEMBLY INSTALLATION BLOWOFF TO STREET W-23
22 DETAIL OF SLOPE PROTECTION W-26/S-26
23 C A U T I O N w A T E R P I P E L I N E CALL BEFORE DIGGING 10' OFFSET CVWD (760) ' OFFSET A V UTILITY MARKER POST W-27/S-38
24 DETAIL OF 4" OR 6" DETECTOR CHECK WITH BY-PASS METER INSTALLATION FOR DUCTILE IRON PIPE W-30
25 DETAIL OF 8" DETECTOR CHECK WITH BY-PASS METER INSTALLATION FOR DUCTILE IRON PIPE W-31B
26 TEMPORARY BACTERIA-SAMPLE RISER DETAIL W-32
27 DETAIL OF WET BARREL TYPE FIRE HYDRANT INSTALLATION ADJACENT TO SIDEWALK OR CURB FOR DUCTILE IRON PIPE W-33A
28 DETAIL OF WET BARREL TYPE FIRE HYDRANT INSTALLATION UNIMPROVED STREET FOR DUCTILE IRON PIPE W-34A
29 CP TEST STATION DETAIL W-36A
30 WIRE LABELING IDENTIFICATION W-36B
31 DETAIL OF CATHODIC PROTECTION TEST STATION-IMPROVED AREAS W-36C
32 PIPE CASING CATHODIC PROTECTION W-36D
33 DETAIL OF 10" DETECTOR CHECK WITH BY-PASS METER INSTALLATION FOR DUCTILE IRON PIPE W-38
34 SEE STANDARD DRAWING W-7, W-9, AND W-11 TYPICAL DETAIL OF INDIVIDUAL 1" PRESSURE REDUCING VALVE INSTALLATION W-39
35 STANDARD CASING FOR DOMESTIC WATER MAINS W-40
36 A A DETAIL "B" PLAN SECTION "A-A" INLET FOR BLOW-OFF WATER AT WELL SITES (GRAVITY FLOW ONLY) W-41
37 SAMPLE STATION W-42
38 WELL SITE GATES & DETAILS W-43
39 STANDARD PIPE GATE ASSEMBLY W-44
40 DETAIL OF DOMESTIC WATER BEE PROOF METER READING LID W-45
41 DETAIL OF WELL DESTRUCTION W-46
42 6" x 1-2 1/2" TEMPORARY BLOW-OFF END OF MAIN INSTALLATION DOMESTIC WATER PIPES W-47
43 System Static Pressure, psi Hydrostatic Testing Maximum Allowable Leakage per 1,000 feet of Pipeline, Gallons per Hour Test Pressure Nominal Pipe Diameter, in or less L = SD P 148,000 HYDROSTATIC TESTING ALLOWABLE LEAKAGE CHART FOR TESTING DOMESTIC WATER PIPES W-48
44 GUARD POST DETAIL W-49
45 DOUBLE CHECK BACKFLOW PREVENTER ASSEMBLY FOR SIZES 4" THROUGH 10" W-50
46 CHAIN LINK FENCE GATES W-51
47 CHAIN LINK FENCE W-52
TABLE OF CONTENTS I-1 INTRODUCTION TO STANDARD DESIGNS 03/17/08
TABLE OF CONTENTS Sheet Number Title Revision Date I-1 INTRODUCTION TO STANDARD DESIGNS 03/17/08 STREETS ST-1 LOCAL STREETS 03/17/08 ST-1A LOCAL STREETS, 2015 GENERAL PLAN 11/15/04 ST-2 COLLECTOR AND ARTERIAL
More informationStandard Drawings Table of Contents
Standard Drawings Table of Contents 1. Standard Symbols, Abbreviations, & Legends 2. 1 Water Service 3. 1 ½ or 2 Water Service 4. 3 Water Service 5. 1 ½ 3 Water Service Manifold Assembly 6. 2 Blow Off
More informationCITY OF OZARK STANDARD DRAWING DETAILS FOR PUBLIC IMPROVEMENTS
CITY OF OZARK STANDARD DRAWING DETAILS FOR PUBLIC IMPROVEMENTS 2010 EDITION CITY OF OZARK, MISSOURI REVISIONS TO THE 2009 EDITION The following revisions have been made to the 2009 edition of the city
More informationDEPARTMENT OF PUBLIC WORKS & UTILITIES
CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS & UTILITIES URBAN SERVICES STANDARDS AND GUIDELINES January 2017 Craig Fulton, P.E., Director TABLE OF CONTENTS "URBAN SERVICES STANDARDS AND GUIDELINES"
More informationCITY OF PASADENA FIRE DEPARTMENT
Page 1 of 8 CITY OF PASADENA FIRE DEPARTMENT INSTALLATION OF COMMERCIAL SPRINKLERS (Revised 12/10/2014) SCOPE: This standard applies to the design and installation of automatic fire sprinkler systems in
More informationC. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.
SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this
More informationAUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)
AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations) This standard applies to the design and installation of automatic fire sprinkler systems in conjunction with
More informationSITE IMPROVEMENTS TO UAS AREA CP1512R
RANGE ROAD SITE IMPROVEMENTS TO UAS AREA CP1512R ROOSEVELT BLVD ACCESS ROAD DUFFY ROAD MARINE CORPS AIR STATION CHERRY POINT, NORTH CAROLINA INDEX OF DRAWINGS 748 LORD DUNMORE DRIVE, SUITE 101 RW 14L RW
More informationCITY OF LATHROP. Department of Public Works. DESIGN & CONSTRUCTION Standard Details
CITY OF LATHROP Department of Public Works DESIGN & CONSTRUCTION Standard Details January 2014 General G-1A Signature Blocks G-1B Signature Blocks G-2 Drafting Standards G-3 Drafting Standards G-4 Drafting
More informationCOBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM
SECTION 21 10 00 PART 1 - GENERAL 1.1 CODES A. Work shall conform to NFPA 13 Sprinkler Systems, 2002 Edition and NFPA 24 Outside Protection, 2002 Edition. NFPA 14 Standpipe Systems, 2000 Edition and International
More informationGLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE
GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE To: From: Subject: Whom It May Concern Carl Ray Austerman, Fire Marshal Contractor s Guide Welcome to the Glendale Fire Department s Contractors Guide. This
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationSAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION
Quality Products & Value Packages Residential Solutions FIRE PROTECTION COMFORTSUSTAINABILITYCONTROL PRESSURE REGULATORS TRENCH DRAINSHVAC SYSTEMS SAFETY ANTI-SCALE SYSTEMS HEATING & COOLING CONTROLS PLUMBING
More informationCity of Vista Fire Department
City of Vista Fire Department Development Services Section 600 Eucalyptus Avenue, Vista CA 92084 Guideline: Underground Piping for Private Fire Hydrants & Fire Sprinkler Supply. Updated: January, 2008
More informationOrange Township Fire Department Fire Prevention Bureau
Orange Township Fire Department Fire Prevention Bureau Under Ground Fire Protection Plan Submittal Checklist Project Name: Project Address: Date: Designers Name: Company Name: Phone Number: Email: Fax:
More informationEL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD INSTALLATION OF COMMERCIAL FIRE SPRINKLER SYSTEMS STANDARD #C-001 EFFECTIVE 03-25-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain
More informationFIRE INSPECTION CHECKLIST
Applicable Base Codes FIRE INSPECTION CHECKLIST Florida Fire Prevention Code, 5th Edition NFPA 1, Uniform Fire Code, Florida 2012 Edition NFPA 101, Life Safety Code, Florida 2012 Edition NFPA 13, 2010
More informationDOCUMENT TABLE OF CONTENTS
DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026
More information1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.
FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment
More informationSECTION SPRINKLER SYSTEMS
SECTION 15325 SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Wet-pipe sprinkler systems. B. Preaction sprinkler systems. C. System design, installation, and certification. D. Fire department
More informationAPPENDIX F: DETAIL DRAWINGS
APPENDIX F: DETAIL DRAWINGS DRAWING DIVISION 100 GENERAL NOTES 200 ROAD WAYS 300 TRAFFIC CONTROL 400 FENCES 500 SEDIMENT CONTROL 600 SANITARY AND STORM SEWERS 700 WATERMAIN 800 PARKS AND LANDSCAPING 900
More informationFIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.
15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.
More informationGLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE
GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE To: Contractors From: Charles Jenkins, Fire Marshal Subject: Contractor s Guide This guide is provided by the Fire Marshal as a service to the construction
More information1.1 SECTION INCLUDES.1 Materials and installation for aboveground oil storage tanks..2 Section Waste Management and Disposal.
Page 1 of 8 PART 1 GENERAL 1.1 SECTION INCLUDES.1 Materials and installation for aboveground oil storage tanks. 1.2 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management
More informationNew Construction Fire Inspection Process
New Construction Fire Inspection Process This document is intended to provide the Owner, Designer, and/or Contractor of new construction with an outline of required fire inspections and with the specific
More informationDESIGN & CONSTRUCTION GUIDELINES
ADMINISTRATIVE SERVICES 4202 E. FOWLER AVENUE, FPC110 PHONE: (813) 974-2625 FACILITIES PLANNING & CONSTRUCTION TAMPA, FLORIDA 33620-7550 WEBSITE: USF.EDU/FPC DESIGN & CONSTRUCTION GUIDELINES DIVISION 21
More informationWayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No
SECTION 213113 - ELECTRIC-DRIVE, CENTRIFUGAL FIRE PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationPort of St Helens SIA Aircraft Hanger Scappoose, OR
Port of St Helens SIA Aircraft Hanger Scappoose, OR AUTOMATIC FIRE SPRINKLER SYSTEM REVISION 2 MARCH 12, 2018 Scope: Furnish and install foam and water fire protection system including underground entrance
More informationPROJECT AND PUBLIC UTILITY CONTACTS VILLAGE OF BEAR LAKE PO BOX VIRGINIA STREET BEAR LAKE, MI (231) VILLAGE OF BEAR LAKE
MAPLE ST. WISE ST. LYNN ST. VIRGINIA ST. SMITH ST. RUSSELL ST. BODWELL ST. RUSSELL ST. MANISTEE COUNTY CHIGAN USDA WATER SYSTEM IMPROVEMENTS PROJECT CONTRACT 1 - DISTRIBUTION SYSTEM VICINITY MAP Know what's
More informationPLAN REVIEW SUBMITTAL GUIDE
PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide
More information007100S01 - PROGRAM DESIGN CRITERIA
Related Division Contents: 00 PROGRAM DESIGN 01 GENERAL INFORMATION 33 CENTRAL STEAM PIPING AND EQUIPMENT 21 FIRE PROTECTION PIPING AND EQUIPMENT 33 MAIN CAMPUS CENTRAL CHILLED WATER SYSTEM 07 ROOFING
More informationCubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM
SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for
More informationREFRIGERANT PIPING SYSTEM
PART 1 GENERAL 1.01 DESCRIPTION A. The requirements of this section apply to the refrigerant piping system connecting refrigeration and HVAC equipment specified in other sections of these specifications.
More informationUL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.
UL/FM Fire Protection Products Reliable fire protection products for your commercial, industrial, or institutional property. Reliable UL/FM Fire Protection Products Markets Power Institutional Company
More informationUL/FM Fire Protection Products Setting the Standard
UL/FM Fire Protection Products Setting the Standard Markets Power Institutional Company Overview Mueller Canada is a leader in high-quality commercial and institutional fire protection products, offering
More informationVSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.
Brochure# 228E 122011 TYPE VSA SEWAGE PUMP Capacities to 100 gpm, Heads to 120, Horsepower range 3/ thru 0, 3 thru discharge, 1750 and 1150 operation. HIGHLIGHTS Wet-Pit Installations Pumps Suspend From
More informationProvidence Water. Water Main Rehabilitation 2019 Project Overview. Edgewood, City of Cranston
1 Providence Water Water Main Rehabilitation 2019 Project Overview Edgewood, City of Cranston Wednesday, April 10, 2019 Rhode Island Shriners Imperial Room 2 Providence Water Source of Supply Supply Source:
More informationProject No. Tract No. APN ETo Zone No. MAWA = ccf ETWU = ccf
Project Name Project Location COACHELLA VALLEY WATER DISTRICT LANDSCAPE AND IRRIGATION PRE-SUBMITTAL CHECKLIST ORDINANCE NO. 1302.2 (This submittal checklist does not include all the requirements of the
More informationSECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Codes and Standards: A. Plumbing Code Compliance: Comply with applicable portions of National Standard Plumbing Code pertaining to selection and installation of Plumbing materials
More information2016 Plumbing Supplemental Plan Review List
Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for
More informationNEW WATER CONNECTION PROCEDURES FOR HOPE AND EDENVILLE TOWNSHIP RESIDENTS
NEW WATER CONNECTION PROCEDURES FOR HOPE AND EDENVILLE TOWNSHIP RESIDENTS WATER DISTRICT NO. 1 of MIDLAND COUNTY Office Location: 246 E. Price Rd. Midland, MI 48642 Mailing Address: PO Box 320 Sanford,
More informationConstruction and Installation Instructions For the A&A Splash Pad
Construction and Installation Instructions For the A&A Splash Pad Revised 9//09 These instructions are not meant to be detailed construction plans since you will be using your standard plumbing and deck
More informationB. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationJOB CREATION PROJECTS
SPRINGDALE INFRASTRUCTURE DEVELOPMENT PLAN JOB CREATION PROJECTS The following pages provide a narrative description, preliminary street alignment and a preliminary construction cost estimate for each
More informationPS12 CITY OF TERRE HAUTE VIGO COUNTY, INDIANA DRAWING NO. EXISTING AND NEW STRUCTURE DATA TABLE JW, CM. No. DATE DESCRIPTION REVISED BY JLH ACS
C JW, CM EXISTING AND NEW STRUCTURE DATA TABLE PS12 #5933 NEW OUTFALL STRUCTURE #1 1"=60' EXISTING OPENING THROUGH TREE LINE ( SEWER AND OUTFALL STRUCTURE SHALL BE INSTALLED AT THIS LOCATION TO AVOID ANY
More informationUL/FM Fire Protection Products Setting the Standard
UL/FM Fire Protection Products Setting the Standard Markets Power Institutional Company Overview Mueller Co. is a leader in high-quality commercial and institutional fire protection products, offering
More informationWater Distribution Study Guide Class III (Made available by: Kansas Rural Water Association)
Water Distribution Study Guide Class III (Made available by: Kansas Rural Water Association) 1. Which one of the following types of pumps works on the basis of inertia or mass moving in a circular motion?
More informationD-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING
D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationSECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE
SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department
More informationDIVISION 21 - FIRE SUPPRESSION
DIVISION 21 - FIRE SUPPRESSION DESIGN CRITERIA It is the policy of UC Davis to install fire sprinkler systems in all new construction/facilities. If the building is classified as a pole barn, shed, carport,
More informationSECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE
SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department
More informationUL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.
UL/FM Fire Protection Products Reliable fire protection products for your commercial, industrial, or institutional property. Reliable UL/FM Fire Protection Products Markets Power Institutional Company
More informationTABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7
TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1
More informationHEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods
230520 HEAT GENERATION Cornell s Design and Construction Standards provide mandatory design constraints and acceptable or required products for all construction at Cornell University. These standards are
More information2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7
WET SPRINKLER Monthly Wet Sprinkler 2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 VISUALS [per NFPA 25-1998 ed] 1. Gauge (Ck for Condition, Normal Pressure) [per 2-2.4.1] 2. Valves
More informationContren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters
Contren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters (Published jointly by American Fire Sprinkler Association and the National Center for Construction Education and Research.)
More informationSTANDARD SPECIFICATIONS Book 2 ENGINEERING DRAWINGS INCLUDES ADDENDUMS
STANDARD SPECIFICATIONS Book 2 ENGINEERING DRAWINGS INCLUDES ADDENDUMS July 23, 2018 Page 1 of 7 STANDARD LEGEND SYMBOLS (September, 1973)... AS-101A STANDARD LEGEND SYMBOLS (September, 1973)... AS-101B
More informationLetter of Credit Itemized Cost Estimate For: 100% Site Development Costs
Letter of Credit Itemized Cost Estimate For: 100% Site Development Costs The following form is to be filled out by the Project Consultant(s) and submitted to the City of Kitchener, Planning Division for
More informationWINTER OUTDOOR LIVESTOCK WATERING It s all about the Energy Choices
Livestock Watering Order No. 590.307-3 January 2006 WINTER OUTDOOR LIVESTOCK WATERING It s all about the Energy Choices This Factsheet outlines options for livestock watering in winter conditions with
More informationCounty of El Dorado Standard Plans
County of El Dorado Standard Plans Table of Contents Section 1 General Standards GS-01 General Legend and Abbreviations Section 2 Roads and Streets RS-01 RS-02 RS-03 RS-04 RS-05 RS-06 RS-07 RS-08 RS-20
More informationDIVISION 21 FIRE SUPPRESSION FIRE SUPPRESSION GENERAL PROVISIONS .1 PREPARATION OF CONTRACT DOCUMENTS
2006 Edition, Published January 1, 2006; Division Revision Date: June 30, 2016 21 00 00. FIRE SUPPRESSION 21 00 03. GENERAL PROVISIONS.1 PREPARATION OF CONTRACT DOCUMENTS.1.1 PLUMBING CONTRACT: Include
More informationDIVISION 21 - FIRE SUPPRESSION
DIVISION 21 - FIRE SUPPRESSION DESIGN CRITERIA It is the policy of UC Davis to install fire sprinkler systems in all new construction/facilities. If the building is classified as a pole barn, shed, carport,
More informationMontgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040
Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 SPRINKLER SHOP DRAWINGS 2007 NFPA 13 and 2007 NFPA 24 Project: Listed items require sprinkler
More informationSTEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationAPPENDIX J ILLUSTRATIONS
The following figures have been included in the 1994 edition of the Standard Plumbing Code to aid in interpreting this code. The figures are not to be construed as superseding the written text, but merely
More informationYour Single Source Partner with Watts for a Comprehensive Suite of Innovative Water Solutions
Your Single Source Partner with Watts for a Comprehensive Suite of Innovative Water Solutions WATER UALITY ACKFLOW REVENTION LUMBING & LOW CONTROL OneWattsWater.com Watts is the Smart Choice Foodservice
More informationSECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section
PART 1 - GENERAL 1.00 GENERAL PROVISIONS A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section 1.01 DESCRIPTION OF WORK A. Work Included: Provide
More informationNEW WATER CONNECTION PROCEDURES
NEW WATER CONNECTION PROCEDURES For Lincoln, Jerome, Village of Sanford WATER DISTRICT NO. 1 of MIDLAND COUNTY Office Location: 246 E. Price Rd. Midland, MI 48642 Mailing Address: PO Box 320 Sanford, MI
More informationJoseph Brennemann Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationDean Pump High Temperature Chemical Process Inline Pumps
Bulletin C-1.2.21. Dean Pump High Temperature Chemical Process Inline Pumps Series DL Dean Pump Series DL High Temperature Chemical Process Inline Pumps Capacities to 600 GPM (182 m 3 /hr) Heads to 0 feet
More informationOKLAHOMA STATE UNIVERSITY - BUILDING DESIGN STANDARDS
Page 1 PART 1 GENERAL 1.1 SUMMARY A. Work of this section includes providing basic mechanical materials including, but not limited to, the following: 1. Valves. 2. Pipe expansion joints. 3. Supports and
More informationWest District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8
City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire
More informationVALVES SECTION 15100
VALVES SECTION 15100 PART 1 GENERAL 1.1 DESCRIPTION A. The requirements of this SECTION apply to all Work of this DIVISION where applicable. The valves, materials, and methods herein are generally common
More informationFlow Control for Fire Protection
Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality
More informationTo expedite the plan review and inspection processes, please refer to the information below.
Guidelines: The goal of the Denison Fire Department is to assist its customers in understanding our submittal, plan review and inspection process and policies, as they pertain to new construction. Familiarity
More informationFlow Control for Fire Protection
Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality
More informationGas Station & C Store SECTION CWM Job No
SECTION 21 1300 - PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract
More informationThe following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors.
The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors. You can complete the test by printing a hard copy, or
More informationSECTION PLUMBING EQUIPMENT
PART 1 GENERAL 1.01 SECTION INCLUDES A. Water heaters. B. Packaged water heating systems. C. Domestic water heat exchangers. D. Water storage tanks. E. Water softeners. F. Reverse osmosis equipment. G.
More informationYour Single. Source. Partner with Watts Water. for a Comprehensive Suite. of Innovative Water Solutions. OneWattsWater.com
Your Single Source Partner with Watts Water for a Comprehensive Suite of Innovative Water Solutions OneWattsWater.com SINCE 1874 INNOVATIVE SOLUTIONS RESIDENTIAL CONST COMMERCIAL CONSTRUCTION MUNICIPAL
More informationTOWN OF GUILDERLAND SWIMMING POOL REGULATIONS. D. Pools under 48" in height but more than 24" deep require a barrier.
1. BUILDING PERMITS A. All pools over 24" in depth require a building permit. B. All pool enclosures require a building permit. C. All decks require a building permit. D. Pools under 48" in height but
More informationDIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES
DIVISION 21 FIRE SUPPRESSION PART 1 GENERAL 1.01 DESCRIPTION A. Provide UL listed, FM approved listed fire protection specialties or accessories as required by either the equipment manufacturer or the
More informationEnvironmental Health & Safety
Environmental Health & Safety Oklahoma State University FIRE SPRINKLER SYSTEM STANDARD Environmental Health and Safety University Health Services Suite 002 Stillwater, OK 74078 (405) 744-7241 www.ehs.okstate.edu
More informationADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri
ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1 TO CONTRACT DOCUMENTS ENTITLED: PROJECT MANUAL FOR: Women s and Children s Hospital New Water Service Main PROJECT NUMBER: CP172631 ADVERTISEMENT DATE: July
More informationSECTION WET-PIPE FIRE SUPPRESSION SPRINKLERS
SECTION 15932 WET-PIPE FIRE SUPPRESSION SPRINKLERS PART 1 - GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred
More informationRevision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.
SECTION 211300 FIRE SUPPRESSION SYSTEMS 1.0 All new and renovated buildings shall be provided with automatic sprinklers throughout and fire standpipe systems. The design and installation of these systems
More informationWhite Street Area Sewer Separation, Project ID Date Issued: June 8, 2015
White Street Area Sewer Separation, Project ID 11240090 Date Issued: June 8, 2015 ADDENDUM NO. 3 This addendum will only be distributed via e-mail, but will remain available for viewing on the MSDGC website
More informationA. This section includes design and performance information for fire protection and suppression systems.
SECTION 21 00 10: FIRE PROTECTION SYSTEM DESIGN 1. SUMMARY A. This section includes design and performance information for fire protection and suppression systems. 2. GENERAL A. All fire protection materials
More informationMound System Pressure Distribution Worksheet
Mound System Pressure Distribution Worksheet Number of bedrooms Septic tank size Minimum 1000 gallons Dosing tank size Minimum 800 gallons or 1 bedroom smaller than septic tank size whichever is larger
More informationSanitary Drainage Systems
11.1 MATERIALS See Section 3.1. Sanitary Drainage Systems 11.2 BUILDING SEWERS AND BUILDING DRAINS 11.2.1 Sewer or Drain in Filled Ground Chapter 11 Building sewers or building drains that are installed
More informationUNIVERSITY OF MISSOURI Central Station Air-Handling Units March
GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous
More information/s/ Michael T. Loeffler. Michael T. Loeffler Senior Director, Certificates and External Affairs. Attachment. September 14, 2018.
Northern Natural Gas Company P.O. Box 3330 Omaha, NE 68103-0330 402 398-7200 September 14, 2018 Via efiling Ms. Kimberly D. Bose, Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington,
More informationFire District Dwelling Construction Requirements
Fire District Dwelling Construction Requirements Includes Sacramento County Fire Marshals Association Standard for Residential Sprinklers City of Rancho Cordova Building & Safety Department 2729 Prospect
More informationDiscontinued Product
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Victaulic Series 759 alarm check valve works as a check valve by preventing the reverse flow of water from the system piping to the water supply. The valve
More informationDIVISION 15 MECHANICAL
DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with
More informationSeries 759 FireLock Alarm Check Valve
R IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS 10.70 Series 759 FireLock Alarm Check Valve Grooved Grooved PRODUCT DESCRIPTION U L FM U L C See Victaulic publication 10.01 for details. The Victaulic
More informationICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.
ICP Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A 1 inch diameter faucet, where the inside edge of the spout opening is 2.5 inches away
More informationUsed Fluid Handling Portable Used Oil Gravity Drains
Portable Used Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)
More information