Field settings table [6.8.2] =... ID66F2. Applicable units *BLQ05CAV3 *DLQ05CAV3 *BLQ07CAV3 *DLQ07CAV3. Notes (*1) *B* (*2) *D* 1/8

Size: px
Start display at page:

Download "Field settings table [6.8.2] =... ID66F2. Applicable units *BLQ05CAV3 *DLQ05CAV3 *BLQ07CAV3 *DLQ07CAV3. Notes (*1) *B* (*2) *D* 1/8"

Transcription

1 /8 [6.8.2] =... ID66F2 Applicable units *BLQ5CAV3 *DLQ5CAV3 *BLQ7CAV3 *DLQ7CAV3 Notes (*) *B* (*2) *D*

2 2/8 User settings Preset values Room temperature Comfort (heating) R/W [3-7]~[3-6], step: A C Eco (heating) R/W [3-7]~[3-6], step: A C Comfort (cooling) R/W [3-8]~[3-9], step: A C Eco (cooling) R/W [3-8]~[3-9], step: A C LWT main [8-9] Comfort (heating) R/W [9-]~[9-], step: C [8-A] Eco (heating) R/W [9-]~[9-], step: C [8-7] Comfort (cooling) R/W [9-3]~[9-2], step: C 8 C [8-8] Eco (cooling) R/W [9-3]~[9-2], step: C Comfort (heating) R/W -~, step: C Eco (heating) R/W -~, step: C -2 C Comfort (cooling) R/W -~, step: C Eco (cooling) R/W -~, step: C 2 C Tank temperature [6-A] Storage comfort R/W 3~[6-E] C, step: C [6-B] Storage eco R/W 3~min(5, [6-E]) C, step: C [6-C] Reheat R/W 3~min(5, [6-E]) C, step: C Quiet level R/W : Level : Level 2 2: Level 3 Electricity price [C-C] [D-C] High R/W,~99/kWh /kwh [C-D] [D-D] Medium R/W,~99/kWh /kwh [C-E] [D-E] Low R/W,~99/kWh /kwh Fuel price R/W,~99/kWh,~29/MBtu 8,/kWh Set weather dependent Main Set weather-dependent heating [-] Set weather-dependent heating Low ambient temp. for LWT main zone heating R/W -4~, step: C [-] Set weather-dependent heating High ambient temp. for LWT main zone heating [-2] Set weather-dependent heating Leaving water value for low ambient temp. for LWT main zone heating R/W [9-]~[9-] C, step: C [-3] Set weather-dependent heating Leaving water value for high ambient temp. for LWT main zone heating R/W [9-]~min(45, [9-]) C, step: C Set weather-dependent cooling [-6] Set weather-dependent cooling Low ambient temp. for LWT main zone cooling [-7] Set weather-dependent cooling High ambient temp. for LWT main zone cooling R/W 25~43 C, step: C [-8] Set weather-dependent cooling Leaving water value for low ambient temp. for LWT main zone cooling R/W [9-3]~[9-2] C, step: C [-9] Set weather-dependent cooling Leaving water value for high ambient temp. for LWT main zone cooling R/W [9-3]~[9-2] C, step: C 8 C Additional Set weather-dependent heating [-] Set weather-dependent heating Leaving water value for high ambient temp. for LWT add zone heating R/W [9-5]~min(45,[9-6]) C, step: C [-] Set weather-dependent heating Leaving water value for low ambient temp. for LWT add zone heating R/W [9-5]~[9-6] C, step: C [-2] Set weather-dependent heating High ambient temp. for LWT add zone heating [-3] Set weather-dependent heating Low ambient temp. for LWT add zone heating R/W -4~, step: C - Set weather-dependent cooling [-4] Set weather-dependent cooling Leaving water value for high ambient temp. for LWT add zone cooling R/W [9-7]~[9-8] C, step: C 8 C [-5] Set weather-dependent cooling Leaving water value for low ambient temp. for LWT add zone cooling R/W [9-7]~[9-8] C, step: C 2 C [-6] Set weather-dependent cooling High ambient temp. for LWT add zone cooling R/W 25~43 C, step: C [-7] Set weather-dependent cooling Low ambient temp. for LWT add zone cooling Installer settings System layout Standard A.2.. [E-] Unit type R/O ~5 2: Monobloc A.2..2 [E-] Compressor type R/O ~ : 8 A.2..3 [E-2] Indoor software type R/O : Type (*) : Type 2 (*2) A.2..7 [C-7] Unit control method R/W : LWT control : Ext RT control 2: RT control A.2..8 [7-2] Number of LWT zones R/W : LWT zone : 2 LWT zones A.2..9 [F-D] Pump operation mode R/W : Continuous : Sample 2: Request (*) *B*_(*2) *D*

3 3/8 A.2..A [E-4] Power saving possible R/O : No A.2..B User interface location R/W : At unit : In room A.2..C [E-D] Glycol present Options A.2.2.A [D-2] DHW pump : Secondary rtrn 2: Disinf. Shunt 3: Circul. Pump 4: CP & disinf. Sh A.2.2.B [C-8] External sensor : Outdoor sensor 2: Room sensor Control box A.2.2.E. [E-3] Backup heater steps BUH : step 2: 2 steps A.2.2.E.2 [5-D] BUH type R/W ~5 : P,(/+2) 4: 3PN,(/2) 5: 3PN,(/+2) A.2.2.E.3 [D-] Preferential kwh rate : Open tariff 2: Closed tariff A.2.2.E.4 [E-5] DHW operation A.2.2.E.5 [C-5] Contact type main R/W : Thermo ON/OFF 2: C/H request A.2.2.E.6 [C-6] Contact type add. R/W ~2 : Thermo ON/OFF Option box A.2.2.F. [C-2] Ext. backup heat src R/W ~3 A.2.2.F.2 [C-9] Alarm output rmally open : Normally closed A.2.2.F.3 [D-8] External kwh meter :, pulse/kwh 2: pulse/kwh 3: pulse/kwh 4: pulse/kwh 5: pulse/kwh A.2.2.F.4 [D-9] External kwh meter 2 :, pulse/kwh 2: pulse/kwh 3: pulse/kwh 4: pulse/kwh 5: pulse/kwh A.2.2.F.5 [C-8] External sensor : Outdoor sensor 2: Room sensor A.2.2.F.6 [D-4] PCC by digital inputs Capacities A.2.3. [6-2] Booster heater R/W ~kw, step:,2kw 3kW A [6-3] BUH: step R/W ~kw, step:,2kw 3kW A [6-4] BUH: step 2 R/W ~kw, step:,2kw kw Space operation LWT settings Main A.3... LWT setpoint mode R/W : Fixed : Weather dep. 2: Fixed + scheduled 3: WD + scheduled A [9-] Temperature range Minimum temp (heating) R/W 5~37 C, step: C A [9-] Temperature range Maximum temp (heating) R/W 37~, step: C A [9-3] Temperature range Minimum temp (cooling) R/W 5~8 C, step: C A [9-2] Temperature range Maximum temp (cooling) R/W 8~, step: C A [8-5] Modulated LWT A [9-B] Emitter type R/W : Quick : Slow Additional A LWT setpoint mode R/W : Fixed : Weather dep. 2: Fixed + scheduled 3: WD + scheduled A [9-5] Temperature range Minimum temp (heating) R/W 5~37 C, step: C A [9-6] Temperature range Maximum temp (heating) R/W 37~, step: C A [9-7] Temperature range Minimum temp (cooling) R/W 5~8 C, step: C A [9-8] Temperature range Maximum temp (cooling) R/W 8~, step: C Delta T source A [9-9] Heating R/W 3~, step: C A [9-A] Cooling R/W 3~, step: C Room thermostat A [3-7] Room temp. range Minimum temp (heating) R/W 2~8 C, step: A C A [3-6] Room temp. range Maximum temp (heating) R/W 8~3, step: A A [3-9] Room temp. range Minimum temp (cooling) R/W 5~, step: A (*) *B*_(*2) *D*

4 4/8 A [3-8] Room temp. range Maximum temp (cooling) R/W 25~, step: A A [2-A] Room temp. offset R/W -5~, step:, A [2-9] Ext. room sensor offset R/W -5~, step:, A Room temp. step R/W :,5 C : C Operation range A.3.3. [4-2] Space heating OFF temp R/W 4~35 C, step: C A [F-] Space cooling On temp R/W ~, step: C Domestic hot water (DHW) Type A.4. [6-D] R/W : Reheat only : Reheat + sched. 2: Scheduled only Disinfection A.4.4. [2-] Disinfection A [2-] Operation day R/W : Each day : Monday 2: Tuesday 3: Wednesday 4: Thursday 5: Friday 6: Saturday 7: Sunday A [2-2] Start time R/W ~23 hour, step: hour 23 A [2-3] Temperature target R/W 55~8, step: 7 A [2-4] Duration R/W 5~6 min, step: 5 min min Maximum setpoint A.4.5 [6-E] R/W 4~8, step: C 6 SP mode A.4.6 R/W : Fixed : Weather dep. Weather dependent curve A.4.7 [-B] Weather-dependent curve Leaving water value for high ambient temp. for DHW R/W 35~[6-E] C, step: C A.4.7 [-C] Weather-dependent curve Leaving water value for low ambient temp. for DHW R/W 45~[6-E] C, step: C 6 A.4.7 [-D] Weather-dependent curve High ambient temp. for DHW A.4.7 [-E] Weather-dependent curve Low ambient temp. for DHW R/W -4~, step: C - Heat sources Backup heater A.5.. [4-] Operation mode R/W ~2 : Disabled A.5..3 [4-7] Enable BUH step 2 A.5..4 [5-] Equilibrium temp. R/W -5~, step: C -4 C System operation Auto restart A.6. [3-] Preferential kwh rate A.6.2. [D-] Allowed heaters ne : BSH only 2: BUH only 3: All heaters A [D-5] Forced pump OFF R/W : Forced off : As normal Pwr consumpt. Control A.6.3. [4-8] Mode limitation : Continuous 2: Digital inputs A [4-9] Type R/W : Current : Power A [5-5] Amp. value R/W ~5 A, step: A 5 A A [5-9] kw value R/W ~2 kw, step:,5 kw 2 kw A [5-5] Amp. limits for DI Limit DI R/W ~5 A, step: A 5 A A [5-6] Amp. limits for DI Limit DI2 R/W ~5 A, step: A 5 A A [5-7] Amp. limits for DI Limit DI3 R/W ~5 A, step: A 5 A A [5-8] Amp. limits for DI Limit DI4 R/W ~5 A, step: A 5 A A [5-9] kw limits for DI Limit DI R/W ~2 kw, step:,5 kw 2 kw A [5-A] kw limits for DI Limit DI2 R/W ~2 kw, step:,5 kw 2 kw A [5-B] kw limits for DI Limit DI3 R/W ~2 kw, step:,5 kw 2 kw A [5-C] kw limits for DI Limit DI4 R/W ~2 kw, step:,5 kw 2 kw A [4-] Priority ne : BSH 2: BUH Averaging time A.6.4 [-A] averaging : 2 hours 2: 24 hours 3: 48 hours 4: 72 hours Ext amb. sensor offset (*) *B*_(*2) *D*

5 5/8 A.6.5 [2-B] R/W -5~, step:, Boiler efficiency A.6.A [7-5] R/W : Very high : High 2: Medium 3: Low 4: Very low Emergency A.6.C R/W : Manual : Automatic Overview settings A.8 [-] Leaving water value for high ambient temp. for LWT add zone heating R/W [9-5]~min(45,[9-6]) C, step: C A.8 [-] Leaving water value for low ambient temp. for LWT add zone heating R/W [9-5]~[9-6] C, step: C A.8 [-2] High ambient temp. for LWT add zone heating A.8 [-3] Low ambient temp. for LWT add zone heating R/W -4~, step: C - A.8 [-4] Leaving water value for high ambient temp. for LWT add zone cooling R/W [9-7]~[9-8] C, step: C 8 C A.8 [-5] Leaving water value for low ambient temp. for LWT add zone cooling R/W [9-7]~[9-8] C, step: C 2 C A.8 [-6] High ambient temp. for LWT add zone cooling R/W 25~43 C, step: C A.8 [-7] Low ambient temp. for LWT add zone cooling A.8 [-B] Leaving water value for high ambient temp. for DHW R/W 35~[6-E] C, step: C A.8 [-C] Leaving water value for low ambient temp. for DHW R/W 45~[6-E] C, step: C 6 A.8 [-D] High ambient temp. for DHW A.8 [-E] Low ambient temp. for DHW R/W -4~, step: C - A.8 [-] Low ambient temp. for LWT main zone heating R/W -4~, step: C - A.8 [-] High ambient temp. for LWT main zone heating A.8 [-2] Leaving water value for low ambient temp. for LWT main zone heating R/W [9-]~[9-], step: C A.8 [-3] Leaving water value for high ambient temp. for LWT main zone heating R/W [9-]~min(45, [9-]) C, step: C A.8 [-4] Weather dependent cooling of the main leaving water temperature zone. R/W : Disabled A.8 [-5] Weather dependent cooling of the additional leaving water temperature zone R/W : Disabled A.8 [-6] Low ambient temp. for LWT main zone cooling A.8 [-7] High ambient temp. for LWT main zone cooling R/W 25~43 C, step: C A.8 [-8] Leaving water value for low ambient temp. for LWT main zone cooling R/W [9-3]~[9-2] C, step: C A.8 [-9] Leaving water value for high ambient temp. for LWT main zone cooling R/W [9-3]~[9-2] C, step: C 8 C A.8 [-A] What is the averaging time for the outdoor temp? averaging : 2 hours 2: 24 hours 3: 48 hours 4: 72 hours A.8 [2-] When should the disinfection function be executed? R/W : Each day : Monday 2: Tuesday 3: Wednesday 4: Thursday 5: Friday 6: Saturday 7: Sunday A.8 [2-] Should the disinfection function be executed? A.8 [2-2] When should the disinfection function start? R/W ~23 hour, step: hour 23 A.8 [2-3] What is the disinfection target temperature? R/W 55~8, step: 7 A.8 [2-4] How long must the tank temperature be maintained? R/W 5~6 min, step: 5 min min A.8 [2-5] Room antifrost temperature R/W 4~6 C, step: C 6 C A.8 [2-6] Room frost protection R/W : Disabled A.8 [2-9] Adjust the offset on the measured room temperature R/W -5~, step:, A.8 [2-A] Adjust the offset on the measured room temperature R/W -5~, step:, A.8 [2-B] What is the required offset on the measured outdoor temp.? R/W -5~, step:, A.8 [3-] Is auto restart of the unit allowed? A.8 [3-] -- A.8 [3-2] -- A.8 [3-3] -- 4 A.8 [3-4] -- 2 A.8 [3-5] -- A.8 [3-6] What is the maximum desired room temperature in heating? R/W 8~3, step: A A.8 [3-7] What is the mimimum desired room temperature in heating? R/W 2~8 C, step: A C A.8 [3-8] What is the maximum desired room temperature in cooling? R/W 25~, step: A A.8 [3-9] What is the minimum desired room temperature in cooling? R/W 5~, step: A A.8 [4-] What is the BUH operation mode? R/W ~2 : Disabled (*) *B*_(*2) *D*

6 6/8 A.8 [4-] Which electric heater has priority? ne : BSH 2: BUH A.8 [4-2] Below which outdoor temperature is heating allowed? R/W 4~, step: C A.8 [4-3] Operation permission of the booster heater. R/W : Limited : No limit 2: Most optimum 3: Optimum 4: Only legionella A.8 [4-4] How to protect the water pipes from freezing R/W : Continuous pump operation : Intermittent pump operation 2: No protection A.8 [4-5] -- A.8 [4-6] -- (Do not change this value) / A.8 [4-7] Enable the second step of the backup heater? A.8 [4-8] Which power limitation mode is required on the system? limitation : Continuous 2: Digital inputs A.8 [4-9] Which power limitation type is required? R/W : Current : Power A.8 [4-A] -- A.8 [4-B] Automatic cooling/heating changeover hysteresis. R/W ~, step:, C A.8 [4-D] Automatic cooling/heating changeover offset. R/W ~, step:, 3 C A.8 [4-E] Is the installer on site? A.8 [5-] Is backup heater operation allowed above equilibrium temperature during space heating operation? R/W : Allowed : Not allowed A.8 [5-] What is the equilibrium temperature for the building? R/W -5~, step: C -4 C A.8 [5-2] Space heating priority. R/W : Disabled A.8 [5-3] Space heating priority temperature. R/W -5~, step: C A.8 [5-4] Set point correction for domestic hot water temperature. R/W ~, step: C A.8 [5-5] What is the requested limit for DI? R/W ~5 A, step: A 5 A A.8 [5-6] What is the requested limit for DI2? R/W ~5 A, step: A 5 A A.8 [5-7] What is the requested limit for DI3? R/W ~5 A, step: A 5 A A.8 [5-8] What is the requested limit for DI4? R/W ~5 A, step: A 5 A A.8 [5-9] What is the requested limit for DI? R/W ~2 kw, step:,5 kw 2 kw A.8 [5-A] What is the requested limit for DI2? R/W ~2 kw, step:,5 kw 2 kw A.8 [5-B] What is the requested limit for DI3? R/W ~2 kw, step:,5 kw 2 kw A.8 [5-C] What is the requested limit for DI4? R/W ~2 kw, step:,5 kw 2 kw A.8 [5-D] What type of backup heater installation is used? R/W ~5 : P,(/+2) 4: 3PN,(/2) 5: 3PN,(/+2) A.8 [5-E] -- A.8 [6-] The temperature difference determining the heat pump ON temperature. R/W 2~, step: C 2 C A.8 [6-] The temperature difference determining the heat pump OFF temperature. R/W ~, step: C 2 C A.8 [6-2] What is the capacity of the booster heater? R/W ~kw, step:,2kw 3kW A.8 [6-3] What is the capacity of the backup heater step? R/W ~kw, step:,2kw 3kW A.8 [6-4] What is the capacity of the backup heater step 2? R/W ~kw, step:,2kw kw A.8 [6-5] -- A.8 [6-6] -- A.8 [6-7] -- A.8 [6-8] What is the hysteresis to be used in reheat mode? R/W 2~, step: C A.8 [6-9] -- A.8 [6-A] What is the desired comfort storage temperature? R/W 3~[6-E] C, step: C A.8 [6-B] What is the desired eco storage temperature? R/W 3~min(5, [6-E]) C, step: C A.8 [6-C] What is the desired reheat temperature? R/W 3~min(5, [6-E]) C, step: C A.8 [6-D] What is the desired DHW production type? R/W : Reheat only : Reheat + sched. 2: Scheduled only A.8 [6-E] What is the maximum temperature setpoint? R/W 4~8, step: C 6 A.8 [7-] Domestic hot water booster heater overshoot temperature. R/W ~4 C, step: C A.8 [7-] Domestic hot water booster heater hysteresis. R/W 2~4, step: C 2 C A.8 [7-2] How many leaving water temperature zones are there? R/W : LWT zone : 2 LWT zones A.8 [7-3] -- 2,5 A.8 [7-4] -- A.8 [7-5] Boiler efficiency R/W : Very high : High 2: Medium 3: Low 4: Very low A.8 [8-] -- min A.8 [8-] Maximum running time for domestic hot water operation. R/W 5~95 min, step: 5 min 3 min A.8 [8-2] Anti-recycling time. R/W ~ hour, step:,5 hour 3 hour (*) *B*_(*2) *D*

7 7/8 A.8 [8-3] Booster heater delay timer. R/W 2~95 min, step: 5 min 5 min A.8 [8-4] Additional running time for the maximum running time. R/W ~95 min, step: 5 min 95 min A.8 [8-5] Allow modulation of the LWT to control the room temp? A.8 [8-6] Leaving water temperature maximum modulation. R/W ~, step: C 3 C A.8 [8-7] What is the desired comfort main LWT in cooling? R/W [9-3]~[9-2], step: C 8 C A.8 [8-8] What is the desired eco main LWT in cooling? R/W [9-3]~[9-2], step: C A.8 [8-9] What is the desired comfort main LWT in heating? R/W [9-]~[9-], step: C A.8 [8-A] What is the desired eco main LWT in heating? R/W [9-]~[9-], step: C 4 A.8 [8-B] -- 3 A.8 [8-C] -- A.8 [8-D] -- 6 A.8 [9-] What is the maximum desired LWT for main zone in heating? R/W 37~, step: C A.8 [9-] What is the mimimum desired LWT for main zone in heating? R/W 5~37 C, step: C A.8 [9-2] What is the maximum desired LWT for main zone in cooling? R/W 8~, step: C A.8 [9-3] What is the mimimum desired LWT for main zone in cooling? R/W 5~8 C, step: C A.8 [9-4] Leaving water temperature overshoot temperature. R/W ~4 C, step: C C A.8 [9-5] What is the mimimum desired LWT for add. zone in heating? R/W 5~37 C, step: C A.8 [9-6] What is the maximum desired LWT for add. zone in heating? R/W 37~, step: C A.8 [9-7] What is the mimimum desired LWT for add. zone in cooling? R/W 5~8 C, step: C A.8 [9-8] What is the maximum desired LWT for add. zone in cooling? R/W 8~, step: C A.8 [9-9] What is the desired delta T in heating? R/W 3~, step: C A.8 [9-A] What is the desired delta T in cooling? R/W 3~, step: C A.8 [9-B] What emitter type is connected to the main LWT zone? R/W : Quick : Slow A.8 [9-C] Room temperature hysteresis. R/W ~6 C, step:, C A.8 [9-D] Pump speed limitation R/W ~8, step: : % ~4 : 8~5% 5~8 : 8~5% 6 A.8 [9-E] -- 6 A.8 [A-] -- A.8 [A-] -- A.8 [A-2] -- A.8 [A-3] -- A.8 [A-4] -- A.8 [B-] -- A.8 [B-] -- A.8 [B-2] -- A.8 [B-3] -- A.8 [B-4] -- A.8 [C-] -- A.8 [C-] -- A.8 [C-2] -- A.8 [C-3] Bivalent activation temperature. R/W -25~, step: C A.8 [C-4] Bivalent hysteresis temperature. R/W 2~, step: C 3 C A.8 [C-5] What is the thermo request contact type for the main zone? R/W : Thermo ON/OFF 2: C/H request A.8 [C-6] What is the thermo request contact type for the add. zone? R/W ~2 : - : Thermo ON/OFF A.8 [C-7] What is the unit control method in space operation? R/W : LWT control : Ext RT control 2: RT control A.8 [C-8] Which type of external sensor is installed? : Outdoor sensor 2: Room sensor A.8 [C-9] What is the required alarm output contact type? rmally open : Normally closed A.8 [C-A] -- A.8 [C-C] High electricity price decimal (Do not use) R/W ~7 A.8 [C-D] Medium electricity price decimal (Do not use) R/W ~7 A.8 [C-E] Low electricity price decimal (Do not use) R/W ~7 A.8 [D-] Which heaters are permitted if prefer. kwh rate PS is cut? ne : BSH only 2: BUH only 3: All heaters A.8 [D-] Forced off contact type R/W ~3 : No : Open tariff 2: Closed tariff A.8 [D-2] Which type of DHW pump is installed? : Secondary rtrn 2: Disinf. Shunt 3: Circul. Pump 4: CP & disinf. Sh A.8 [D-3] Leaving water temperature compensation around. R/W : Disabled, shift 2 C (from -2 to 2 C) 2: Enabled, shift 4 C (from -2 to 2 C) 3: Enabled, shift 2 C (from -4 to 4 C) 4: Enabled, shift 4 C (from -4 to 4 C) (*) *B*_(*2) *D*

8 8/8 A.8 [D-4] Is the option box used for PCC? A.8 [D-5] Is the pump allowed to run if prefer. kwh rate PS is cut? R/W : Forced off : As normal A.8 [D-7] -- A.8 [D-8] Is an external kwh meter used for power measurement? :, pulse/kwh 2: pulse/kwh 3: pulse/kwh 4: pulse/kwh 5: pulse/kwh A.8 [D-9] Is an external kwh meter used for power measurement? :, pulse/kwh 2: pulse/kwh 3: pulse/kwh 4: pulse/kwh 5: pulse/kwh A.8 [D-A] -- A.8 [D-B] -- 2 A.8 [D-C] What is the high electricity price (Do not use) R/W ~49 A.8 [D-D] What is the medium electricity price (Do not use) R/W ~49 A.8 [D-E] What is the low electricity price (Do not use) R/W ~49 A.8 [E-] Which type of unit is installed? R/O ~5 2: Monobloc A.8 [E-] Which type of compressor is installed? R/O ~ : 8 A.8 [E-2] What is the indoor unit software type? R/O : Type (*) : Type 2 (*2) A.8 [E-3] What is the number of backup heater steps? BUH : step 2: 2 steps A.8 [E-4] Is the power saving function available on the outdoor unit? R/O : No A.8 [E-5] Can the system prepare domestic hot water? A.8 [E-6] -- A.8 [E-7] -- A.8 [E-8] Power saving function for outdoor unit. R/W : Disabled A.8 [E-9] -- A.8 [E-A] -- A.8 [E-B] -- A.8 [E-C] -- A.8 [E-D] Is the system filled with glycol? A.8 [F-] Pump operation allowed outside range. R/W : Disabled A.8 [F-] Above which outdoor temperature is cooling allowed? R/W ~, step: C A.8 [F-2] -- 3 A.8 [F-3] -- 5 A.8 [F-4] -- A.8 [F-5] -- A.8 [F-6] -- A.8 [F-9] Pump operation during flow abnormality. R/W : Disabled A.8 [F-A] -- A.8 [F-B] -- A.8 [F-C] -- A.8 [F-D] What is the pump operation mode? R/W : Continuous : Sample 2: Request (*) *B*_(*2) *D*

1/8. Field settings table [6.8.2] =... ID66F3. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P E

1/8. Field settings table [6.8.2] =... ID66F3. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P E /8 [6.8.2] =... ID66F3 Applicable indoor units *HYHBH5AAV3 *HYHBH8AAV3 *HYHBX8AAV3 Notes - 4P35373-E - 27.2 2/8 User settings Preset values Room temperature 7.4.. Comfort (heating) R/W [3-7]~[3-6], step:

More information

1/8. Field settings table. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P C

1/8. Field settings table. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P C 1/8 Applicable indoor units *HYHBH5AAV3 *HYHBH8AAV3 *HYHBX8AAV3 Notes - 4P353731-1C - 213.12 2/8 3/8 User settings Preset values Room temperature 7.4.1.1 Comfort (heating) R/W [3-7]~[3-6], step: A.3.2.4

More information

1/8. Field settings table. Applicable indoor units. *GSQH10S18AA9W ThermaliaC12* Notes - *GSQH10S18AA9W / ThermaliaC12* 4P C

1/8. Field settings table. Applicable indoor units. *GSQH10S18AA9W ThermaliaC12* Notes - *GSQH10S18AA9W / ThermaliaC12* 4P C 1/8 Applicable indoor units *GSQH1S18AA9W ThermaliaC12* Notes - *GSQH1S18AA9W / ThermaliaC12* 4P359382-1C - 214.3 2/8 3/8 User settings Preset values Room temperature 7.4.1.1 Comfort (heating) R/W [3-7]~[3-6],

More information

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 English Table of Contents Table of Contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview:

More information

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump. EGSQH0S8AA9W English Table of contents Table of contents About this document About the system Components in a typical system layout Operation Overview: Operation The user interface at a glance Buttons

More information

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump. English Table of contents Table of contents About this document About the system. Components in a typical system layout... 3 Operation 3 3. Overview: Operation... 3 3. The user interface at a glance...

More information

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB EHBH04CB EHBH08CB EHBHCB EHBH6CB EHBX04CB EHBX08CB EHBXCB EHBX6CB EHVH04S8CB EHVH08S8CB EHVH08S6CB EHVHS8CB EHVHS6CB EHVH6S8CB EHVH6S6CB EHVX04S8CB EHVX08S8CB EHVX08S6CB EHVXS8CB EHVXS6CB EHVX6S8CB EHVX6S6CB

More information

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV EHVH04S18CBV EHVH08S18CBV EHVH08S26CBV EHVH11S26CBV EHVH16S26CBV English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL Installation and operation manual Table of contents Page 1. Supplied accessories and intended use... 1 2. General layout and setup of a system... 2 3. Installation...

More information

Public. Altherma by Daikin. Altherma Commissioning Service Field Settings

Public. Altherma by Daikin. Altherma Commissioning Service Field Settings Public Altherma by Daikin Altherma Commissioning Service Field Settings Altherma Service Settings There are several service codes that can be altered to maximise the efficiency of the Altherma system.

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL Installation and operation manual Table of contents Page. Supplied accessories and intended use.... General layout and setup of a system... 3. Installation... 3 3.. Mounting

More information

Operation manual. ROTEX HPU hybrid heat pump module RHYHBH05AA RHYHBH08AA RHYHBX08AA. Operation manual ROTEX HPU hybrid heat pump module.

Operation manual. ROTEX HPU hybrid heat pump module RHYHBH05AA RHYHBH08AA RHYHBX08AA. Operation manual ROTEX HPU hybrid heat pump module. RHYHBH05AA RHYHBH08AA RHYHBX08AA English Table of contents Table of contents Target audience End users Documentation set About this document About the system Components in a typical system layout Operation

More information

User reference guide. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

User reference guide. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB EHVH04S18CB EHVH08S18CB EHVH08S26CB EHVH11S18CB EHVH11S26CB EHVH16S18CB EHVH16S26CB EHVX04S18CB EHVX08S18CB EHVX08S26CB EHVX11S18CB

More information

OPERATING MANUAL. Need Help? This manual covers: T955WH Wireless Thermostat System. Table of Contents

OPERATING MANUAL. Need Help? This manual covers: T955WH Wireless Thermostat System. Table of Contents OPERATING MANUAL This manual covers: T955WH Wireless Thermostat System Your wireless thermostat system includes a master thermostat (T955WH) and base module. The T955WH thermostat communicates wirelessly

More information

OPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB

OPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB OPERATION MANUAL Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB EKHBH016AB*** EKHBX016AB*** Indoor unit for hot water heat pump system and options CONTENTS Page Introduction...1

More information

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help? INSTALLATION MANUAL This manual covers the following models: T955W Master Thermostat Base Module Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency

More information

ST 53.1 User s manual

ST 53.1 User s manual Tech - 1 - ST 53.1 User s manual Table of contents I. Safety... 3 II. Description... 4 III. Installation... 4 IV. Operating the Controller... 6 IV.a) Principle of Operation... 6 IV.b) Control... 6 V. Controller

More information

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control For the owner and the heating engineer Operating and Installation Manual VRC 400 Programmable weather compensator with separat HW time control GB Contents Contents Notes on the documentation..... 4 Symbols

More information

ECL Comfort 210 / 296 / 310

ECL Comfort 210 / 296 / 310 User Guide ECL Comfort 210 / 296 / 310 English version www.danfoss.com Safety Note Necessary assembly, start-up, and maintenance work must be performed by qualified and authorized personnel only. 2 Danfoss

More information

Condensing Boiler RS100 Controller Training Program

Condensing Boiler RS100 Controller Training Program Condensing Boiler RS100 Controller Training Program Training Program #501102A 062311 www.rinnai.us 2009 Rinnai America Corporation Features and Benefits The RS100 connects directly to the boiler and acts

More information

FREQUENTLY ASKED QUESTIONS

FREQUENTLY ASKED QUESTIONS HEAT PUMP INVERTER R-410A All-in-one, all year round heating, cooling and domestic hot water supply solution FREQUENTLY ASKED QUESTIONS WANT TO KNOW MORE? AVERAGE ANNUAL CO 2 EMISSIONS Daikin Altherma

More information

/18 (JRK) MTD User Manual OJ Electronics A/S

/18 (JRK) MTD User Manual OJ Electronics A/S 67772 02/18 (JRK) MTD3-1999 User Manual Table of Contents Introduction.................................. 3 Menu Overview................................ 4 Icons....................................... 5

More information

Installation & User s Instructions

Installation & User s Instructions Installation & User s Instructions 8 080 shown Part No. 00 day Wired Digital Programmer & Room Sensor Part No. 080 day Wireless Digital Programmer & Room Sensor Part No. 00 hr Wireless Digital Programmer

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

Operating Functions Temperature Parameters

Operating Functions Temperature Parameters Operating Functions Temperature Parameters Room set temperature (T set) Room ambient temperature (T amb) Fundamental Functions After powered on, no matter when the compressor is started, the time interval

More information

Control Application. Supplement - ACVMax

Control Application. Supplement - ACVMax prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

MTC User Manual

MTC User Manual 67564 05/16 (JRK) MTC3-1991 User Manual WWW.MICRO-MATIC.NO Contents Contents.................................... 2 Introduction.................................. 3 Menu Overview................................

More information

Installation Guide. ECL Comfort 210, application A Table of Contents

Installation Guide. ECL Comfort 210, application A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning G2524en Heating controller Installation Instructions RVL471 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a

More information

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER

More information

prestige Control Application Supplement - ACVMax

prestige Control Application Supplement - ACVMax 2015-10 Prestige ACVMax Control Sup 12-14-15_ACVMax_Control 12/15/15 7:36 AM Page 1 prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory

More information

REMOTE CONTROL FOR CHILLER MYCHILLER

REMOTE CONTROL FOR CHILLER MYCHILLER REMOTE CONTROL FOR CHILLER MYCHILLER GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD... 5 BOARD CONFIGURATION... 7 LIST OF MAIN PARAMETERS... 7 CONFIGURATION OF MAIN

More information

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later Overview Modbus can access single adresses or multiple addresses simultaneously; either reading or writing

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER! WARNING Revise boiler control parameters only if you fully understand the purpose and result of the changes and on the advice of ECR Technical

More information

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422 ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single

More information

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4 Operating instructions multimatic VRC 700f/4 AT, BE (de), CH (de), DE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 2810 info@vaillant.de

More information

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1 OPERATION MANUAL EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1 EKHVMRD50+80ABV1 EKHVMYD50+80ABV1 CONTENTS Page 1. Definitions... 1 2. Introduction... 2 2.1. General information... 2 2.2. Scope

More information

T855S. Caution. Page. Table of Contents Table of Contents Thermostat Operation Thermostat Quick Reference Programming Features Warranty Information

T855S. Caution. Page. Table of Contents Table of Contents Thermostat Operation Thermostat Quick Reference Programming Features Warranty Information Operation Manual Operation Manual Pro1 Technologies 1111 S. Glenstone Ave., Suite 2-100 Springfield, MO 65804 Toll Free: 888-776-1427 Web: www.pro1iaq.com Hours of Operation: M-F 9AM - 6PM Eastern T855S

More information

OPERATING MANUAL. Need Help? This manual covers the following models: T805. Table of Contents

OPERATING MANUAL. Need Help? This manual covers the following models: T805. Table of Contents OPERATING MANUAL This manual covers the following models: T80 Congratulations on purchasing a new thermostat. This thermostat was designed to the highest reliability and ease of use standards. Thank you

More information

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O HMC300 Control unit EMS plus 6 720 808 471-00.1O Operating Instructions 6 720 813 192 (2014/10) Contents Contents Key to symbols and safety instructions................3 1.1 Key to symbols...........................

More information

THE HEAT PUMP CHOICE OF PROFESSIONALS

THE HEAT PUMP CHOICE OF PROFESSIONALS THE HEAT PUMP CHOICE OF PROFESSIONALS T H E E N E R G Y E F F I C I E N T H E AT I N G S Y S T E M TIME FOR ENERGY EFFICIENT AND INNOVATIVE SOLUTIONS Expectations of consumers are changing. With the high

More information

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort User manual CLIMATIC 2/4 - Controller Providing indoor climate comfort MUL35E-56 9-26 INDEX CONTENTS PAGE INDEX 1 GENERAL DESCRIPTION 2 THE KEYPAD, Climatic 2 3 THE KEYPAD, Climatic 4 4 THE KEYPAD REMOTE

More information

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions Lago SD3 Differential Controller with Speed Control Operating and Installation Instructions Please observe the safety instructions and read through this manual carefully before commissioning the equipment.

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The

More information

OPERATING MANUAL. This manual covers TopTech models: TT-S-855 and T855

OPERATING MANUAL. This manual covers TopTech models: TT-S-855 and T855 OPERATING MANUAL This manual covers TopTech models: TT-S-8 and T8 Congratulations on purchasing a new thermostat. This thermostat was designed to the highest reliability and ease of use standards. Thank

More information

Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~ Providing sustainable energy solutions worldwide

Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~ Providing sustainable energy solutions worldwide 162 105 46-7 Providing sustainable energy solutions worldwide Installation and Maintenance Manual CTC EcoHeat 400 400V 3N~ / 230V 1N~ IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE REFERENCE 2016-06-28

More information

OJ Waterline control system

OJ Waterline control system OJ Waterline control system THERMOSTATS FOR COMFORT HEATING AND SNOW MELTING Product presentation Mk3 It s all about Room Temperature Control! The essential main goals are: Comfort Flexibility Reliability

More information

Operating instruction. Remote control station WCM-FS /

Operating instruction. Remote control station WCM-FS / 83277702 1/22-04 1 User instructions... 4 1.1 User instructions... 4 1.2 User guide... 4 1.2.1 Symbols... 4 1.2.2 Target group... 4 1.3 Guarantee and Liability... 4 2 Safety... 5 2.1 Permissible application...

More information

RVL47. Heating Controller. Installations Instructions. Installation

RVL47. Heating Controller. Installations Instructions. Installation Heating Controller Installations Instructions Installation Place of installation - In a dry room, e.g. the boiler room - Mounting choices: - In a control panel (on the inner wall or on a DIN mounting rail)

More information

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution! SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS DE L AIR Comfort Module 5-2 kw Choose the easy heating solution! Comfort Module: heating with Carrier system innovation Proper control of heat pumps is key to

More information

Odyssey. issue 01c. system manual

Odyssey. issue 01c. system manual dyssey issue 01c system manual SYSTEM MANUAL Table of Contents Technical Specification 1 Summary of Features 2 General Description 3 Control ptions 4 Description of Main Features 5 Control Schemes 6 Installation

More information

Capacity controller for water chiller AK-CH 650

Capacity controller for water chiller AK-CH 650 Capacity controller for water chiller AK-CH 650 Menu operation via AKM Menu list This menu function can be used together with system software type AKM. The description is divided up into function groups

More information

Operating Instructions

Operating Instructions Operating Instructions Control panel Logamatic 4323 For the user Please read carefully before use 6 720 618 563-11/2008 US/CA Contents 1 Introduction................................................ 4 2

More information

Modbus TCP/IP Version 4.0 and Modbus RTU Gateway Version 2.4

Modbus TCP/IP Version 4.0 and Modbus RTU Gateway Version 2.4 Modbus TCP/IP Version 4.0 and Modbus RTU Gateway Version 2.4 Overview ModBus can access single addresses or multiple addresses simultaneously; either reading or writing single bit values or 16-bit values.

More information

G a

G a G2474 74 319 0081 0 a en Installation Instructions Heating controllers RVP3... Installation Place of installation In a dry room, e.g. in the boiler room Mounting choices: Control cabinet (in the front,

More information

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY RC 06 0712_1403 it - Istruzioni TELECONTROLLO en - Remote controller instruction hu - Utasítás TÁVVEZÉRLÉS ru - Руководство по эксплуатации pl - Instrukcja obsługi { 1. Commissioning of the boiler 26 2.

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins Table of Contents Parts Diagram........................................................... 1 Icon Descriptions......................................................... 2 Specifications...........................................................

More information

Owner s Manual. Part Number 33CS250-01

Owner s Manual. Part Number 33CS250-01 33CS Commercial Programmable Thermostat IMPORTANT: Read entire instructions before programming the thermostat. Owner s Manual Part Number 33CS250-01 GENERAL Carrier s 7-day, commercial, programmable thermostats

More information

MicroTech Series-200 Flooded Screw Chiller

MicroTech Series-200 Flooded Screw Chiller Open Protocol Data Infomation Packet Version 1.0 Group: Controls Date: February 1997 MicroTech Series-200 Flooded Screw Chiller Open Protocol Data Communications 2002 McQuay International - C O N F I D

More information

Product Manual SZ1009

Product Manual SZ1009 Product Manual SZ1009 Conventional Heating & Cooling Thermostats with Heat Pump Mode Communicating Thermostats Description The SZ1009 is a microprocessor-based mable thermostats designed for conventional

More information

Electronic Pellet Burner Controller NPBC-V3M

Electronic Pellet Burner Controller NPBC-V3M Electronic Pellet Burner Controller NPBC-V3M SOFTWARE VERSION 3.3a/3.2 page of 27 CHANGES IN THE USER MANUAL OR IN THE CONTROLLER'S SOFTWARE Version of the user manual Changes Page 2.2. The software version

More information

DES IGN I T ALI A N O

DES IGN I T ALI A N O DES IGN I T ALI A N O 01-04-2017 1 The innovation at your home 35 years of experience An Italian company with 35 years of experience in biomass heating. Since 1981 we have been producing and offering innovative

More information

Modulating clock thermostat

Modulating clock thermostat EN Digital timer thermosatat Modulating clock thermostat Installation and Service Manual 123189-AB Contents 1 Preface...4 1.1 General...4 2 Location of the installation...5 2.1 Position of the regulator...5

More information

Cooling kit UTW-KCL*D. Installation instructions FR NL EN DE IT. (Compatible with high-flow circulation pump, code UTW-PHF*D)

Cooling kit UTW-KCL*D. Installation instructions FR NL EN DE IT. (Compatible with high-flow circulation pump, code UTW-PHF*D) Document n 1541-1 ~ 24/04/2012 FR NL EN DE IT ES PT Cooling kit UTW-KCL*D (Compatible with high-flow circulation pump, code UTW-PHF*D) 3 8 7 Installation instructions intended for the professional technician

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G4LFCA AS*G4LFCC AS*G0LFCA AO*G4LFL AO*G4LFCC AO*G0LFT R40A CONTENTS. DESCRIPTION OF EACH

More information

prestige Control Application Supplement - Type 5 MCBA WARNING

prestige Control Application Supplement - Type 5 MCBA WARNING prestige Control Application Supplement - Type 5 MCBA WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Installation and Maintenance Manual CTC GSi 12. Modulating ground source heat pump. Providing sustainable energy solutions worldwide

Installation and Maintenance Manual CTC GSi 12. Modulating ground source heat pump. Providing sustainable energy solutions worldwide 162 105 50-1 2015-08-11 Providing sustainable energy solutions worldwide Installation and Maintenance Manual CTC GSi 12 Modulating ground source heat pump Installation and Maintenance Manual CTC GSi 12

More information

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round AIR TO WATER HEAT PUMPS Hot water and comfortable ambient temperature all year round HEAT PUMP PRINCIPLE CARRIER. A UNITED TECHNOLOGIES COMPANY Whether you need air conditioning for a new building or a

More information

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model Air to Water INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE & MONOBLOCK TYPE Compact model is an Economical and Clean hot water heating system by Heat Pump ROOM HEATING HOT WATER is an efficient hot

More information

Drayton Digistat +3RF

Drayton Digistat +3RF Drayton Digistat +3RF Programmable Room Thermostat Wireless 5-2 Day / 7 Day Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845

More information

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating

More information

OWNER S MANUAL. Part Number P

OWNER S MANUAL. Part Number P OWNER S MANUAL CPV230 Commercial Thermostat Part Number P374-2300 CONTENTS Page GENERAL...2 CONFIGURATION...3-12 Thermostat Display...3 Heat or Cool Indicator...4 Thermostat Front Panel Buttons...4 Thermostat

More information

Startup Checklist. check off executed action! Altherma EHS(X/H) Daikin Altherma EHSX Altherma EHSXB Altherma EHSH Altherma EHSHB -08P50AA -16P50AA

Startup Checklist. check off executed action! Altherma EHS(X/H) Daikin Altherma EHSX Altherma EHSXB Altherma EHSH Altherma EHSHB -08P50AA -16P50AA Startup Checklist check off executed action! Daikin Altherma EHSX Altherma EHSXB Altherma EHSH Altherma EHSHB -08P50AA -16P50AA Daikin Altherma EHSX Altherma EHSXB Altherma EHSH Altherma EHSHB -04P30AA

More information

Outline principle. Application Houses with water-borne heating systems. Maximal recommended heating output 13.5 kw. Alternative

Outline principle. Application Houses with water-borne heating systems. Maximal recommended heating output 13.5 kw. Alternative Outline principle Application Houses with water-borne heating systems. Maximal recommended heating output 13.5 kw. Alternative NOTE! This is an outline diagram. Actual installation must be project planned

More information

Providing sustainable energy solutions worldwide. Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~

Providing sustainable energy solutions worldwide. Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~ 162 105 30-2 2013-09-23 Providing sustainable energy solutions worldwide Installation and Maintenance Manual CTC EcoHeat 400 400V 3N~ / 230V 1N~ Removing the cooling module 1. Disconnect the cooling module

More information

ALFEA. Commissioning & Services

ALFEA. Commissioning & Services ALFEA & Services 1 Electrical connections 2 2 Hydraulic connections 3 2 Refrigerant connections Extensa + Excellia 4 Heat Pump Report Site : Customer : Installer: Commissioner : Contractor : Outdoor Unit

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

multimatic Operating instructions Operating instructions For the operator AT, BE (de), CH (de), DE VRC 700f/4 Publisher/manufacturer Vaillant GmbH

multimatic Operating instructions Operating instructions For the operator AT, BE (de), CH (de), DE VRC 700f/4 Publisher/manufacturer Vaillant GmbH Operating instructions For the operator Operating instructions multimatic VRC 700f/4 AT, BE (de), CH (de), DE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18

More information

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS Debonair 33CS Flush-Mounted Flatstat Commercial Programmable Thermostat IMPORTANT: Read entire instructions before programming the thermostat. Owner s Manual Part Number 33CS250-FS and 33CS220-FS GENERAL

More information

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE Technical features Guide to LCD symbols Guide to keys Technical features Supply by communication bus Number of temperature levels 2 (DAY / NIGHT) Temperature

More information

T600MEP-2 Programmable Economizer Thermostat

T600MEP-2 Programmable Economizer Thermostat Installation Instructions Issue Date January 19, 2005 T600MEP-2 Programmable Economizer Thermostat Application The T600MEP-2 is a programmable thermostat for control of single- or two-stage unitary rooftop

More information

Heating and D.h.w. Controller RVL482 Basic Documentation

Heating and D.h.w. Controller RVL482 Basic Documentation Heating and D.h.w. Controller RVL482 Basic Documentation Edition: 1.0 Controller series: A CE1P2542en 20.05.2008 Building Technologies Siemens Switzerland Ltd Building Technologies Group International

More information

Digital Thermostat Models: VS30W and VS30B

Digital Thermostat Models: VS30W and VS30B it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014 10:28 Digital Thermostat Models: VS30W and VS30B INSTALLER / USER MANUAL it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014

More information

Daikin Altherma Selection Report

Daikin Altherma Selection Report Daikin Altherma Selection Report Produced on 20.10.2014 with Daikin Altherma Simulator V4.4.7 - database Central 9.7.9 Project name Energa Sistemi Reference Airabela Client name Energa Sistemi Revision

More information

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

SD2. Differential Controller. Operating and Installation Instructions F2 72.3 SD2 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation. Safety

More information

Heating controller with optimisation functions

Heating controller with optimisation functions TAC 2112 C-10-42 Heating controller with optimisation functions 1999.12 The TAC 2112 offers for control of hot water systems. The radiator circuit is controlled according to an outdoor -compensated reset

More information

Air-to-Water Hydromodule + Tank WH-UD05HE5-1 WH-UD07HE5-1 WH-UD09HE5-1. Destination Europe Turkey

Air-to-Water Hydromodule + Tank WH-UD05HE5-1 WH-UD07HE5-1 WH-UD09HE5-1. Destination Europe Turkey Order : PAPAMY1607068CE Air-to-Water Hydromodule + Tank Indoor Unit WH-ADC0309H3E5 Outdoor Unit WH-UD03HE5-1 WH-UD05HE5-1 WH-UD07HE5-1 WH-UD09HE5-1 Destination Europe Turkey WARNING This service information

More information

OPERATION MANUAL. Unit and options for air to water heat pump system EDHQ011BB6V3 EDHQ014BB6V3 EDHQ016BB6V3 EDHQ011BB6W1 EDHQ014BB6W1 EDHQ016BB6W1

OPERATION MANUAL. Unit and options for air to water heat pump system EDHQ011BB6V3 EDHQ014BB6V3 EDHQ016BB6V3 EDHQ011BB6W1 EDHQ014BB6W1 EDHQ016BB6W1 OPERATION MANUAL Unit and options for air to water heat pump system EDHQ011BB6V3 EDHQ014BB6V3 EDHQ016BB6V3 EDHQ011BB6W1 EDHQ014BB6W1 EDHQ016BB6W1 EDLQ011BB6V3 EDLQ014BB6V3 EDLQ016BB6V3 EDLQ011BB6W1 EDLQ014BB6W1

More information

Modbus RTU RS485 Manual

Modbus RTU RS485 Manual Modbus RTU RS485 Manual AUTOMATED FUEL MAINTENANCE SYSTEMS FTI-5A, FTI-10A, FTI-20A FUEL TECHNOLOGIES INTERNATIONAL 06/10/2014 Rev B - Fuel Technologies - Modbus The Modbus Communications Setup Button

More information

prestige Control Application Supplement WARNING

prestige Control Application Supplement WARNING prestige Control Application Supplement WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions within this

More information

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort USER MANUAL S203 Controller for three circuits - control for 2 heating circuits - 1 domestic hot water control Saving energy, creating comfort This user manual consists of two parts. Issues that are intended

More information

YUTAKI M SERIES. Technical Catalogue RHUE-3AVHN1 RHUE-(3-6)A(V)HN-HM

YUTAKI M SERIES. Technical Catalogue RHUE-3AVHN1 RHUE-(3-6)A(V)HN-HM YUTAKI M SERIES Technical Catalogue RHUE-3AVHN1 RHUE-(3-6)A(V)HN-HM Contents Contents General information Features and benefits General data Capacity and selection data Acoustic characteristic curves

More information

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved. Monobloc LG Electronics Commercial Air Conditioning 56, Digital-ro 10-gil, Geumcheon-gu, Seoul, Korea www.lg.com http://partner.lge.com http://www.lgethermav.com Distributed by Copyright 2018 LG Electronics.

More information

ETN-24-SUPER-PROG (US Program - Celsius)

ETN-24-SUPER-PROG (US Program - Celsius) Meitavtec Ltd (Contel group) Tel: 972 (3) 962 6462 Fax: 972 (3) 962 6620 www.meitavtec.com support@meitavtec.com ETN24SUPERPROG (US Program Celsius) Owner s Manual Installation and Operating Instructions

More information

4 Wiring Brochure Wiring and

4 Wiring Brochure Wiring and - Brochure tekmarnet 4 Thermostat 544 D 544 06/05 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough In Wiring Rough-in 4 Wiring

More information

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS... User Manual Contents 1 DOCUMENT REVISION... 4 2 SOFTWARE VERSION... 4 3 BASIC DESCRIPTION... 4 4 BASIC OVERVIEW OF HYDRAULIC DIAGRAMS... 5 4.1 BOILER NOT CONTROLLED BY THE CONTROLLER:... 5 4.2 BOILER CONTROLLED

More information

- Data Brochure tekmarnet 4 Thermostat 542e

- Data Brochure tekmarnet 4 Thermostat 542e - Data Brochure tekmarnet 4 Thermostat 542e D 542e 03/08 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in

More information