Compact 4-way Cassette ( ) Type
|
|
- Kristin Morgan
- 5 years ago
- Views:
Transcription
1 E08-0 Engineering Data Compact 4-way Cassette ( ) Type Indoor Unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor Unit RAV-SP404AT-E RAV-SP44AT-E Contents. Specifications. Connecting pipe length and lift difference between indoor units vs. capacity correction value. Dimension 4. Wiring diagram. Refrigerant cycle diagram 6. Sensible capacity table 7. Part load performance 8. Air speed distribution 9. Sound characteristics (NC-Curve)
2 . Specifications -. Indooor unit (Compact 4-Way Cassette( ) Type) Seires SDI4 SDI4 Model Indoor unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor unit RAV-SP404AT-E RAV-SP44AT-E Cooling capacity (kw) Heating capacity (kw) Power supply phase 0V (0-40V) 0Hz Running current (A) Power consumption (kw).00.9 Power factor (%) 90 9 Cooling EER.60.6 Energy efficiency class * A A Energy rating **.0 4. Electrical characteristics Running current (A) Power consumption (kw) Power factor (%) 9 9 Heating COP Energy efficiency class * A A Energy rating **..0 Maximum current (A) Main unit Zinc hot dipping steel plate Appearance Ceiling panel Model RBC-UMPG(W)-E (Sold separately) Panel color Moon-white(Muncel.GY 9.0 / 0.) Height (mm) Main unit Width (mm) 7 7 Depth (mm) 7 7 Outer dimension Height (mm) 7 7 Ceiling panel (Sold separately) Width (mm) Depth (mm) Main unit (kg) 7 7 Total weight Ceiling panel (Sold separately) (kg) Heat exchanger Finned tube Fan Turbo fan Turbo fan Fan unit Standard air flow H/M/L (m/min).0 / 9. / / 9. / 7.8 Motor (W) Air filter attached (long life) Controller (Sold Separately) RBC-AMTE, ASE,TCB-AXE Sound pressure level H/M/L (db A) 40 / 6 / 40 / 6 / Sound power level H/M/L (db A) / / 46 / / 46 Connecting pipe * EC standard **AS standard Gas side (mm).7.7 Liquid side (mm) Drain port (mm) VP
3 -. Outdoor unit Model Serieas SDI4 SDI4 Outdoor unit RAV-SP404AT-E RAV-SP44AT-E phase 0V (0-40V) 0Hz Power supply 0Hz(Power exclusive to outdoor is required.) Type Hermetic compressor Compressor Motor (kw).. Pole 4 4 Refirigerant charged (kg).0.0 Refirigerant control Pulse motor valve Standard length (m) Max. total length (m) 0 0 Pipe Additional refrigerant chrge under long piping connection 0g/m(m to 0m) 0g/m(m to 0m) Outdoor lower (m) 0 0 Height difference Outdoor higher (m) 0 0 Height (mm) 0 0 Outer dimension Width (mm) Depth (mm) Appearance Silky shade (Muncel Y8.-0.) Total weight (kg) Heat exchanger Finned tube Fan Propeller fan Fan unit Standard air flow (m/min) Motor (W) 4 4 Gas side (mm).7.7 Connecting pipe Liquid side (mm) Sound pressure level Cooling/Heating (db A) 4/47 4/47 Sound power level Cooling/Heating (db A) 6/64 6/64 Outside air temperature, cooling (C) 4 to - C Outside air temperature, Heating (C) to - C
4 . Connecting pipe length and lift difference between indoor units vs. capacity correction value -. RAV-SM40MUT-E Cooling Cooling performance Outdoor unit hight (m) % 98% 97% 96% 9% 94% Pipe length (m) RAV-SM4MUT-E Heating Heating performance Outdoor unit hight (m) % 9% 90% 8% 80% 7% Pipe length (m) 4
5 Model name MMU-AP007MH MMU-AP009MH MMU-AP0MH MMU-AP0MH MMU-AP08MH 4-way air Discharge Cassete Type Arialbi0c0p4;TOSHIBA CARRIER CORPORATION. Dimension -. RAV-SM40MUT-E/RAV-SM4MUT-E Bottom face of ceiling For branch duct knockout square hole O/ 0 Bottom face of ceiling Electric parts box O/ unit external dimension Knockout for flesh air intake O/ hanging bolt pitch 9 to 660 ceiling open dimension 700 Panel external dimension Refrigerant pipe (Gas) O/.7 Refrigerant pipe (Liquid) O/ hanging bolt pitch 9 to 660 ceiling open dimension 700 Panel external dimension O/ unit external dimension. Hanging bolt M0 or W/8 local arrange Drain discharge port Wiring connection port For branch duct knockout square hole O/ Ceiling panel 7 Bottom face of ceiling (NOTE) As ABS is used for the drain discharge port of the main unit, the vinyl chloride paste cannot be used. Use the flexible hose (Band fix) included in the package. Indoor unit 00 Stand-up 87. or less Stand-up 80 or less 9 to 660 ceiling open dimension 9 to 660 ceiling open dimension Drain-up standing-up size 000 or more or more Bottom face of ceiling Check port ( 40) 000 or more 000 or more or more 00 Wired remote controller RBC-AMTE Simple wired remote controller RBC-ASE Wireless remote controller kit TCB-AXE Weekly timer application RBC-AMTE and RBC-EXWE Obustacle Space required for installation and servicing Note:All dimensions are in mm.
6 4. Wiring diagram 4-. RAV-SM40MUT-E/RAV-SM4MUT-E TA TCJ TC LM LM FM FS CN4 (RED) CN (WHI) 4 4 CN (WHI) 4 4 CN4 (WHI) 4 4 CN68 (BLU) CN04 (YEL) CN7 (CHK) CN7 (DISP) CN0 (RED) Motor drive circuit CN04 (GRY) CN0 (BLK) CN80 (GRN) MCC-40 Power supply circuit Fuse F0 T.A 0V~ DC0V DCV DCV DC7V 4 4 (EXCT) CN7 (RED) Control P.C. Board for Indoor Unit RY 0 RY 0 Fuse F0 0V~ T6.A CN67 (BLK) + ~ ~ RED WHI BLK P0 BLK CN70 (WHI) CN66 (WHI) CN0 (WHI) CN60 (WHI) CN (WHI) (FAN DRIVE) 6 4 Connection interface (option) CN6 (YEL) CN09 (YEL) CN (RED) 4 4 BLK B WHI A CN4 (BLU) P.C. Board CN40 (BLU) U U4 Terminal for central remote controller BLK WHI Adapter for Wireless Remote Controller BLK WHI CN00 (WHI) B A Wired Remote Controller DP NOTE FM : Fan motor TA : Indoor temp. sensor TC : Temp. sensor TCJ : Temp. sensor LM,LM : Louver motor DP : Drain pump motor FS : Float switch RY0 : Drain control relay Serial L N signal Single phase 0 to 40V 0Hz Indoor unit earth screw Outdoor unit earth screw Color Identification BLK : BLACK BLU : BLUE RED : RED GRY : GRAY PNK : PINK GRN : GREEN WHI : WHITE BRN : BROWN ORN : ORANGE YEL : YELLOW 6
7 . Refrigerant cycle diagram -. RAV-SM40MUT-E/RAV- SM4MUT-E RAV-SP404AT-E/RAV-SP44AT-E Indoor unit TCJ sensor TC sensor Air heat exchanger Outer diameter of refrigerant pipe Gas side ØA Liquid side ØB.7mm 6.4mm TS sensor TD sensor -step muffler Ø9.0 00L Refrigerant pipe at gas side Ø.7 Packet valve Packed valve Outer dia. ØA TO sensor Outdoor unit Refrigerant pipe at liquid side Ø6.4 Packet valve Min. m Packed valve Outer dia. ØB PMV (Pulse Motor Valve) (CAM-B0YGTF-) Strainer Max. 0m 4-way valve (STF-008Z) TE sensor Rotary compressor (DA0AF-0F) Muffler Ø9 L60 Heat exchanger Ø8 ripple, rows, 4 steps FP. flat fin Distributor R40A.0 kg Cooling Heating Cooling Heating Pressure (MPa) (kg/cm²g) Discharge Suction Pipe surface temperature ( ÆC) Indoor heat exchanger Outdoor heat exchanger Compressor revolutions per second (rps)* Indoor fan Indoor/Outdoor temp. conditions (DB/WB) ( C) Pd Ps Pd Ps (TD) (TS) (TC) (TE) Indoor Outdoor Standard HIGH 7/9 / Overload HIGH /4 4/ Low load LOW 8/. / Standard HIGH 0/ 7/6 Overload LOW 8/ 4/8 Low load HIGH / 0/(70%) * 4 poles are provided to this compressor. The compressor frequency (Hz) measured with a clamp meter is times of revolutions (rps) of the compressor. * For the details of the outdoor units during twin combination of a digital inverter and a super digital inverter, refer to page 4 (Digital Inverter) and also page 7 (Super Digital Inverter) of the Service Manual File No.A
8 6. Sensible capacity table 6-. Super Digital Inverter 4 Series Sensible Heat Capacity : RAV-SM***MUT-E unit size 40 outdoor air temp. CDB indoor air temp. 4.0CWB.0CWB 6.0CWB 7.0CWB 8.0CWB 9.0CWB 0.0CWB.0CWB 4.0CWB 0.0CDB.CDB.0CDB 4.CDB 6.0CDB 7.0CDB 8.0CDB 0.0CDB.0CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC unit size 4 outdoor air temp. CDB indoor air temp. 4.0CWB.0CWB 6.0CWB 7.0CWB 8.0CWB 9.0CWB 0.0CWB.0CWB 4.0CWB 0.0CDB.CDB.0CDB 4.CDB 6.0CDB 7.0CDB 8.0CDB 0.0CDB.0CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC:Total Capacity [kw] SHC:Sensible Heat Capacity [kw] 8
9 7. Part load performance 7-. Combination Indoor unit : RAV-SM40MUT-E Outdoor unit : RAV-SP404AT-E Cooling Heating Q W Q W MINIMUM RATING Q : Capacity in W W : Power Consumption in W Cooling Outdoor temperature( C) Heating Outdoor temperature( C) Load(%) Q W Q W Q W Q W Q W Load(%) Q W Q W Q W Q W Q W Q W Q W Q W Q W Q W Q W
10 Combination Indoor unit : RAV-SM4MUT-E Outdoor unit : RAV-SP44AT-E Cooling Heating Q W Q W MINIMUM RATING Q : Capacity in W W : Power Consumption in W Cooling Outdoor temperature( C) Heating Outdoor temperature( C) Load(%) Q W Q W Q W Q W Q W Load(%) Q W Q W Q W Q W Q W Q W Q W Q W Q W Q W Q W
11 8. Air speed distribution 8-. RAV-SM40MUT-E/RAV-SM4MUT-E.9m 0.7m/s 0.m/s 0.m/s 0 4 m
12 9. Sound characteristics (NC-Curve) 9-. RAV-SM40MUT-E/RAV-SM4MUT-E Fan tap H M L Sound pressure level (db(a)) Octave band sound pressure level (db) Approximate threshold of hearing for continuous noise H M L NC-0 NC- 40 NC- 0 NC Octave band center frequency (Hz)
13
14 XXX. 008
Digital Inverter 4 series 8 & 10HP
E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct
More informationSERVICE MANUAL/INTEGRATION
FILE. A05-08 Revised: Jul/5/005 SERVICE MANUAL/INTEGRATION SPLIT TYPE INDOOR UNIT RAV-SM56UT-E RAV-SM56BT-E RAV-SM56CT-E RAV-SM80UT-E RAV-SM80BT-E RAV-SM80CT-E RAV-SM0UT-E RAV-SM0BT-E
More informationAIR-CONDITIONER SPLIT TYPE
FILE. A06-00 Revised : Mar. 007 SERVICE MANUAL/INTEGRATION AIR-CONDITIONER SPLIT TYPE INDOOR UNIT RAV-SM56UT-E RAV-SM56BT-E RAV-SM56CT-E RAV-SM80UT-E RAV-SM80BT-E RAV-SM80CT-E RAV-SM0UT-E
More informationSERVICE MANUAL SPLIT TYPE
FILE. A0-04 SERVICE MANUAL SPLIT TYPE RAV-SM560AT-E/RAV-SM800AT-E RAV-SM560UT-E/RAV-SM800UT-E RAV-SM560BT-E/RAV-SM800BT-E RAV-SM560KRT-E/RAV-SM800KRT-E RAV-SM560XT-E/RAV-SM800XT-E R40A PRINTED IN JAPAN,
More informationSERVICE MANUAL SPLIT TYPE R410A <DIGITAL INVERTER> INDOOR UNIT RAV-SM562MUT-E FILE NO. A06-005
FILE. A06-005 SERVICE MANUAL SPLIT TYPE INDOOR UNIT RAV-SM562MUT-E This Service Manual describes contents of the new indoor unit. For the outdoor unit, refer to the Service Manual with
More informationAIR-CONDITIONER SERVICE MANUAL SPLIT TYPE R410A OUTDOOR UNIT
FILE. A09-004 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE OUTDOOR UNIT RAV-SM2244AT8-E RAV-SM2804AT8-E RAV-SM2244AT8Z-E RAV-SM2804AT8Z-E RAV-SM2244AT8ZG-E RAV-SM2804AT8ZG-E RAV-SM2244AT7
More information4-Way Cassette type. Contents MMU-AP 2H2UL
E15-3C1 6 Indoor unit MMU-AP 2H2UL 4-Way Cassette type MMU-AP0072H2UL MMU-AP0092H2UL MMU-AP0122H2UL MMU-AP0152H2UL MMU-AP0182H2UL MMU-AP0212H2UL MMU-AP0242H2UL MMU-AP0302H2UL MMU-AP0362H2UL MMU-AP0422H2UL
More informationSERVICE MANUAL MMU-AP0092H, MMU-AP0122H, MMU-AP0152H, MMU-AP0182H, MMU-AP0242H, MMU-AP0272H, MMU-AP0302H, MMU-AP0362H, MMU-AP0482H, MMU-AP0562H,
FILE NO. A08-004 SERVICE MANUAL MMU-AP0092H, MMU-AP022H, MMU-AP052H, MMU-AP082H, MMU-AP0242H, MMU-AP0272H, MMU-AP0302H, MMU-AP0362H, MMU-AP0482H, MMU-AP0562H, This Service
More informationSERVICE MANUAL AIR CONDITIONER SPLIT TYPE
FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5
More informationAIR-CONDITIONER SPLIT TYPE
FILE. A07-003 Revised:Mar., 2008 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE INDOOR UNIT RAV-SM564UT-E RAV-SM804UT-E RAV-SM04UT-E RAV-SM404UT-E OUTDOOR UNIT RAV-SP404AT-E
More informationCeiling type. Contents MMC-AP 1H2UL MMC-AP0181H2UL MMC-AP0361H2UL MMC-AP0421H2UL
E15-3E1 MMC-AP 1H2UL Ceiling type MMC-AP0181H2UL MMC-AP0241H2UL MMC-AP0361H2UL MMC-AP0421H2UL Contents 1. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical
More informationAir to Water Heat Pump
E15-381 Engineering Data Book Air to Water Heat Pump Hydro Unit HWS-804XWHM3-E1 HWS-804XWHT6-E1 HWS-804XWHT9-E1 HWS-1404XWHM3-E1 HWS-1404XWHT6-E1 HWS-1404XWHT9-E1 Outdoor Unit 8 kw 11/14/16 kw HWS-804H-E1
More informationRAV-SP180AT2-UL (2 HP) RAV-SP240AT2-UL (3 HP) RAV-SP300AT2-UL (4 HP) RAV-SP360AT2-UL (4, 5 HP) RAV-SP420AT2-UL (5 HP)
SERVICE MANUAL FILE. A09-00-2 Revised : Feb. 200 REVISI 2 : Jan.202 Re-edit version.( file volume down) Contents have T been changed. OUTDOOR UNIT SPLIT TYPE RAV-SP80AT2-UL (2
More informationAir to Air Heat Exchanger
Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications
More informationAir to Water Heat Pump
E7- Air to Water Heat Pump Hydro Unit HWS-55XWHM-E HWS-805XWHM-E HWS-805XWHT6-E HWS-805XWHT9-E HWS-05XWHM-E HWS-05XWHT6-E HWS-05XWHT9-E HWS-P805XWHM-E HWS-P805XWHT6-E HWS-P805XWHT9-E HWS-P05XWHM-E HWS-P05XWHT6-E
More informationEngineering. Super Heat Recovery Multi System
Engineering Super-HRM Data Book Super Heat Recovery Multi System Foreword This engineering data book provides several useful data,charts and drawings to clarify the best performance of Toshiba Super Heat
More informationSERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE)
-1 SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) OUTDOOR UNIT RAV-SM564ATP-E (TR) RAV-SM804ATP-E (TR) RAV-SM1104ATP-E (TR) RAV-SM1404ATP-E (TR) RAV-SM564ATJP-E RAV-SM804ATJP-E RAV-SM1104ATJP-E
More informationAIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:
Tel: 08 0 www.heronhill.co.uk Fax: 08 80 TOSHIBA Heronhill - for all your Toshiba requirements FILE NO. A90-00 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE, HEAT PUMP COOLING ONLY WAY CASSETTE TYPE RAV-0TUH--PE
More informationMiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL
MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL 2 Toshiba solutions residential, light commercial and larger commercial buildings. Residential indoor units are designed to blend perfectly with all interiors
More informationLIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises
LIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises Toshiba Heat Pumps. We care about better air. Toshiba was the first company to incorporate inverter technology
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 XS187 & PNRXS187 + CH187 XS187 & PNRXS187 + CL187 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER
More informationAIR CONDITIONER (MULTI TYPE) SERVICE MANUAL
FILE No. A10-033 AIR CONDITIONER (MULTI TYPE) SERVICE MANUAL This service manual provides relevant explanations about new indoor unit (4 series). Please refer to the following service manuals for each
More informationIndex. Toshiba Solutions. Absolute comfort
2 3 Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor units line-up 20 Outdoor units
More informationAIR-CONDITIONER SERVICE MANUAL
FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED
More information1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units
Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply
More informationSERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) RAV-SM1104AT8P-E (TR) RAV-SM1404AT8P-E (TR) RAV-SM1104AT8JP-E RAV-SM1404AT8JP-E
FILE. SVM-17005-2 SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) OUTDOOR UNIT DIGITAL INVERTER> RAV-SM1104AT8P-E (TR) RAV-SM1404AT8P-E (TR) RAV-SM1104AT8JP-E RAV-SM1404AT8JP-E Revised no March, 2017 FILE.
More informationAIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE
-(1) SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-E3 / RAS-24UAH-E3 RAS-18UKHP-E3 / RAS-18UAH-E3 RAS-24UKP-E3 / RAS-24UA-E3 RAS-18UKP-E3 / RAS-18UA-E3 RAS-24UKP-AR3 / RAS-24UA-AR3 RAS-18UKP-AR3
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271
More informationTOSHIBA Carrier (UK) Ltd. LC DX Interface Installation manual ENGLISH. For commercial use. Model name:
TOSHIBA Carrier (UK) Ltd. LC DX Interface Installation manual Model name: For commercial use RAV-DXC010 LC DX Interface ENGLISH Please read this carefully before installing the LC DX interface. This Manual
More informationSERVICE MANUAL MMU-AP0071MH MMU-AP0091MH MMU-AP0121MH MMU-AP0151MH MMU-AP0181MH. <Compact 4-Way Air Discharge Cassette Type> FILE NO.
FILE. A06-002 SERVICE MANUAL MMU-AP007MH MMU-AP009MH MMU-AP02MH MMU-AP05MH MMU-AP08MH This Service Manual describes contents of the Compact 4-Way Air Discharge
More informationAIR-CONDITIONER RAS-M10YKV-E, RAS-M13YKV-E / RAS-M18YAV-E RAS-M10YKCV-E, RAS-M13YKCV-E / RAS-M18YACV-E SERVICE MANUAL SPLIT TYPE R410A SUPPLEMENT
FILE NO. A00-9906 SERVICE MANUAL SUPPLEMENT AIR-CONDITIONER SPLIT TYPE RAS-M10YKV-E, RAS-M13YKV-E / RAS-M18YAV-E RAS-M10YKCV-E, RAS-M13YKCV-E / RAS-M18YACV-E R410A PRINTED IN JAPAN, Nov.,1999 ToMo CONTENTS
More informationfor Light Commercial Use
Inverter Air Conditioning for Light Commercial Use 4 Toshiba's unique energy-efficient air conditioning innovations and technologies deliver high energy savings. Aluminum heat exchanger * High heat exchanger
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL XHS7 & PNRXS87 + CH7 XHS87 & PNRXS87 + CH87 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS7 (PNRXS87) XHS87 (PNRXS87)
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Cassette type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA OUTDOOR AO GLALL AO G4LALL AO G8LALL AO G4LALA . INDOOR UNIT : AU GLVLB AU G4LVLB AU G8LVLB
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS
More informationSuper. Digital Inverter. Inverter Air Conditioning for Light Commercial Use
Super Digital Inverter Inverter Air Conditioning for Light Commercial Use Super Digital Inverter Toshiba Super Digital Inverter series air conditioners combine economy and ecology in a compact body. They
More informationAIR-CONDITIONER SERVICE MANUAL (MULTI TYPE) R410A
FILE NO. A-0 Revision : Jun., 207 SERVICE MANUAL AIR-CONDITIONER (MULTI TYPE) Medium Static Ducted Type MMD- AP0074BH2UL MMD- AP0094BH2UL MMD- AP024BH2UL MMD- AP054BH2UL MMD- AP084BH2UL MMD- AP024BH2UL
More informationPMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100
Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW
More informationProduct Launch SHRMi
Product Launch SHRMi What s SHRM i SMMS i (High Efficiency & Reliability) Simultaneous Operation by heat recovery + = SHRM i meets various customers needs! Refrigerant flow, cooling Liquid pipe Flow selector
More informationAIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE
FILE. SVM-05009-2 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-E4 / RAS-24UAH-E4 RAS-18UKHP-E4 / RAS-18UAH-E4 RAS-24UKP-E4 / RAS-24UA-E4 RAS-18UKP-E4 / RAS-18UA-E4 RAS-24UKP-AR4 / RAS-24UA-AR4
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications
More informationTechnical HandBook. Version
Technical HandBook 24 Hour Technical Helpline: 0870 843 0333 Fault & DN Code Apps: Android & iphone Web Page toshiba calc.co.uk/fault codes/ Fault Code Text Service: 07624 803 017 technical.enquiries@toshiba-ac.com
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02
More informationMiNi-SMMS Design Manual HFC R-410A. Indoor unit. Outdoor unit
Ref.-No. SMME06-111-10-06 MiNi-SMMS Design Manual Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H Compact 4-way ceiling cassette
More informationTABLE OF CONTENTS ERSQ-AAY1
Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 TABLE OF CONTENTS ERSQ-AAY1 1 Features............................................................ 6 2 Specifications......................................................
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...
More informationSimultaneous. Heating and Cooling Solution for Large Buildings. Air Conditioning for large buildings
Simultaneous Heating and Cooling Solution for Large Buildings Air Conditioning for large buildings Toshiba solutions Index Introduction 3 SHRM-e 4 Energy saving 6 Individual temperature control 8 Soft
More informationAIR-CONDITIONER SPLIT TYPE
FILE NO. A06-05 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE INDOOR UNIT Heat Pump Model RAS-M0SMUV-E RAS-M3SMUV-E RAS-M6SMUV-E Cooling Only Model RAS-M0SMUCV-E RAS-M3SMUCV-E RAS-M6SMUCV-E R40A PRINTED IN
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product
More informationRAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E
FILE. A02-05 SPLIT TYPE RAS-0JKVP-E RAS-0JAVP-E RAS-3JKVP-E RAS-3JAVP-E PRINTED IN JAPAN, Mar.,2002 ToMo CONTENTS. SPECIFICATIONS... 3 2. REFRIGERANT R40A... 5 3. CONSTRUCTION VIEWS... 3 4. WIRING DIAGRAM...
More informationtechnical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air
technical data FHYKP-B Ceiling Mounted Corner Cassette air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human
More informationTECHNICAL DATA & SERVICE MANUAL MTF94C5TAA
TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL
More informationCeiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK
T AVAILABLE C AMPM AMPM SPLIT-TYPE, HEAT PUM PAIR CDITIERS No. OC REVISED EDITI-A TECHNICAL & SERVICE MANUAL Series PLH Indoor unit [Model names] PLH-3AK PLH-3AKH PLH-AKS PLH-AKHS PLH-5AKS PLH-5AKHS PLH-6AKS
More informationASU18RLF ASU24RLF AOU18RLXFWH AOU24RLXFWH CONTENTS WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT
WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT Indoor unit ASU8RLF ASURLF Outdoor unit AOU8RLXFWH AOURLXFWH CONTENTS SPECIFICATIONS.................... DIMENSIONS........................
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL KHS308 + CH308 KHS368 + CH368 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KHS308 KHS368 Product Code No. 85 354 8 85 354 9 Outdoor
More informationSingle Fan MiNi VRF Apartment Ready
SINGLE FAN MiNi VRF What you ll find inside: Technology Features Controllers Product specifications Single Phase Energy efficient Heating & cooling Single Fan MiNi VRF Apartment Ready SINGLE FAN MiNi VRF
More informationSide blow VRF. Engineering Data Book. Outdoor units E Model name: MCY-MHP0404HT-E MCY-MHP0504HT-E MCY-MHP0604HT-E
E14-361 Model name: MCY-MHP0404HT-E MCY-MHP0504HT-E MCY-MHP0604HT-E Side blow VRF Engineering Data Book Outdoor units Notice: Toshiba is committed to continuously improving its products to ensure the highest
More informationASU18RLF ASU24RLF AOU18RLXFW1 AOU24RLXFW1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASU8RLF ASURLF Outdoor unit AOU8RLXFW AOURLXFW CONTENTS SPECIFICATIONS.................... DIMENSIONS........................ REFRIGERANT SYSTEM
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01
More informationAir Conditioners. Technical Data FBQ-C
Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Indoor
More informationTECHNICAL DATA & SERVICE MANUAL
TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085
More information6. DUCT TYPE AR 60FUAK, AR 60UUAK
R410A 6. AR 60FUAK, AR 60UUAK ART60UUAK D2D_AR010E/04 2006.05.30 - (06-01) - 6-1. FEATURE MODELS : AR 60FUAK / AO 60FMAYT AR 60UUAK / AO 60UMAYT ART60UUAK / AOT60UMAYT FEATURES Universal design indoor
More informationINVERTER DUCTED SYSTEMS
INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL . INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8 . INDOOR UNIT CONTENTS.
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KE30NKU + CU-KE30NKU CS-KE36NKU + CU-KE36NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KE30NKU CS-KE36NKU Product Code No. 1 852 360 88
More informationSPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL
More informationSERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-12HA RO-12HB C O N T E N T S SPECIFICATIONS........................................ 1 OUTLINE AND DIMENSIONS..............................
More informationPlease read this Installation Manual carefully before installing the. This Manual describes the installation method of the. You must also refer to the
DX Installation manual Outdoor Unit Model name: RAV Digital Inverter and Digital Super Inverter For Commercial Use SM304ATP E SM404ATP E SM564ATP E M804ATP E SM1104ATP 4 P SM2246AT8 E SM2806AT8 E S P 56
More informationAIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE
FILE. SVM-05010-2 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE 42CJR024-723 / 38CJR024-723 42CJR018-723 / 38CJR018-723 42TAR024X-723 / 38TAR024X-723 42TAR018-723 / 38TAR018-723 42HNR024-713 / 38HNR024-713
More informationMUH-24RV - MSH-30RV -
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models Refer to the Service Manual OB85 REVISED EDITION C when MSH-8RV- E is connected with MXZ-NV- E or MXZ-NV- E as multi system units.
More informationRAS-24UKHP-ES-1 / RAS-24UAH-ES-1 RAS-18UKHP-ES2 / RAS-18UAH-ES2 RAS-24UKP-ES-1 / RAS-24UA-ES-1 RAS-18UKP-ES2 / RAS-18UA-ES2
FILE. SVM-03009 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-ES-1 / RAS-24UAH-ES-1 RAS-18UKHP-ES2 / RAS-18UAH-ES2 RAS-24UKP-ES-1 / RAS-24UA-ES-1 RAS-18UKP-ES2 / RAS-18UA-ES2 18 Class (Heat
More informationAIR-CONDITIONER SERVICE MANUAL UNDER CEILING / CONSOLE TYPE
FILE. SVM-02009 SERVICE MANUAL AIR-CONDITIONER UNDER CEILING / CONSOLE TYPE RAS-18UFHP-ES / RAS-18UAH-ES RAS-18UFP-ES / RAS-18UA-ES RAS-24UFHP-ES / RAS-24UAH-ES RAS-24UFP-ES / RAS-24UA-ES 18 Class 24 Class
More informationService Manual AIR TO WATER HEAT PUMP. Outdoor unit. Hydro unit
FILE. A10-1704 AIR TO WATER HEAT PUMP Service Manual Model name: Hydro unit HWS-805XWHM3-E(TR) HWS-805XWHT6-E(TR) HWS-805XWHT9-E HWS-1405XWHM3-E(TR) HWS-1405XWHT6-E(TR) HWS-1405XWHT9-E(TR) Outdoor unit
More informationtechnical data air conditioning systems Indoor Units FBQ-C7VEB
technical data Indoor Units FBQ-C7VEB air conditioning systems technical data Indoor Units FBQ-C7VEB air conditioning systems Indoor Units R-40A FBQ-C7VEB TABLE OF CONTENTS FBQ-C7VEB Features.............................................................
More informationTABLE OF CONTENTS RMXS-E8V1B
Outdoor Units R-410A RMXS-E8V1B TABLE OF CONTENTS RMXS-E8V1B! 1 Features........................................................... 814 2 Specifications.....................................................
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G18LFCA AS G24LFCA AS G30LFCA OUTDOOR AO G18LFC AO G24LFL AO G30LFT 1. INDOOR UNIT : AS G18LFCA AS G24LFCA AS G30LFCA DTR_AS052E_01
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationELECTRICAL QUANTITY WEIGHT (LB)
VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /
More informationAIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE
FILE. SVM-06004 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-18NKHP-E / RAS-18NAH-E RAS-18NKP-E / RAS-18NA-E RAS-24NKP-E / RAS-24NA-E RAS-B18NKPX / RAS-18N2AX RAS-24NKPX / RAS-24N2AX 18 Class 24
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product
More informationBlending Commercial and Residential. MiNi VRF
Blending Commercial and Residential MiNi VRF Toshiba Solutions Delivering Absolute Comfort Toshiba offers a solution for all applications: residential, light commercial and larger commercial buildings.
More informationContent. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...
R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor
More informationFILE NO. SVM SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24NKHP-E / RAS-24NAH-E RAS-18NKPX-T / RAS-18N2AX-T RAS-24NKPX-T / RAS-24N2AX-T
FILE. SVM-06009 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24NKHP-E / RAS-24NAH-E RAS-18NKPX-T / RAS-18N2AX-T RAS-24NKPX-T / RAS-24N2AX-T June, 2006 CONTENTS FILE. SVM-06009 1. SPECIFICATIONS 2.
More informationRAS-M10GKCVP-E RAS-M13GKCVP-E RAS-M16GKCVP-E
FILE. A05-014 SERVICE MANUAL SPLIT TYPE Indoor Unit RAS-M10GKCVP-E RAS-M13GKCVP-E RAS-M16GKCVP-E Outdoor Unit RAS-3M23GACV-E R410A PRINTED IN JAPAN, Jan.,2006 ToMo CONTENTS 1. SAFETY
More informationTECHNICAL & SERVICE MANUAL. Ceiling Concealed
STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A
More informationSERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) RAV-SM564UTP-E (TR) RAV-SM804UTP-E (TR) RAV-SM1104UTP-E (TR) RAV-SM1404UTP-E (TR) RAV-SM1604UTP-E (TR)
-5 SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) INDOOR UNIT RAV-SM564UTP-E (TR) RAV-SM804UTP-E (TR) RAV-SM1104UTP-E (TR) RAV-SM1404UTP-E (TR) RAV-SM1604UTP-E (TR) Revised on Apr. 2014
More informationTECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA
More informationSERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) RAV-SM304ATP-E (TR) RAV-SM404ATP-E (TR) RAV-SM304ATJP-E RAV-SM404ATJP-E OUTDOOR UNIT <DIGITAL INVERTER>
FILE. SVM-14059-3 SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) OUTDOOR UNIT RAV-SM304ATP-E (TR) RAV-SM404ATP-E (TR) RAV-SM304ATJP-E RAV-SM404ATJP-E Revised on July, 2016 Original instruction
More informationPUHZ-SHW140YHA PUHZ-SHW230YKA
1 Specifications Model Name PUHZ-SHW1YHA PUHZ-SHWYKA Power supply (phase, cycle, voltage) 3φ, 0V, Hz 3φ, 0V, Hz Max. current A 13.0 6.0 Breaker size A 16 3 Outer casing Galvanized plate Galvanized plate
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFW AOU24RLXFW 1. INDOOR UNIT : ASU18RLF ASU24RLF DTR_AS51E_1 21.12.22 1. INDOOR UNIT CONTENTS 1. FEATURE...
More informationAIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE
FILE. SVM-06005 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-18NKHD-E5 / RAS-18NAH-E RAS-18NKD-E5 / RAS-18NA-E RAS-24NKD-E5 / RAS-24NA-E RAS-18NKDX5 / RAS-18N2AX RAS-24NKDX5 / RAS-24N2AX 18 Class
More informationTECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER
Manual No. '06 PAC, KX-T-110 TECHNICAL MANUAL Collection data PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) FDUMVA201HEN2R 251HEN2R 302HEN2R 402HEN2R 502HEN2R 602HEN2R MULTI-TYPE (V-MULTI)
More informationService Manual AIR TO WATER HEAT PUMP. Outdoor unit. Hydro unit HWS-804XWHT6-E1(TR) HWS-1104H-E1(TR) HWS-804XWHM3-E1(TR) HWS-804H-E1(TR)
FILE. A10-1502 AIR TO WATER HEAT PUMP Service Manual Model name: Hydro unit Outdoor unit HWS-804XWHM3-E1(TR) HWS-804H-E1(TR) HWS-804XWHT6-E1(TR) HWS-1104H-E1(TR) HWS-804XWHT9-E1 HWS-1404H-E1(TR) HWS-1404XWHM3-E1(TR)
More informationSERVICE MANUAL SPLIT TYPE RAS-10N3AV2-E1 RAS-B10N3KV2-E1 RAS-B13N3KV2-E1 RAS-B16N3KV2-E1 RAS-13N3AV2-E1 RAS-16N3AV2-E R410A. Indoor Unit Outdoor Unit
SERVICE MANUAL Indoor Unit Outdoor Unit RAS-B10N3KV2-E1 RAS-B13N3KV2-E1 RAS-B16N3KV2-E1 SPLIT TYPE RAS-10N3AV2-E1 RAS-13N3AV2-E1 RAS-16N3AV2-E R410A January,
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA 1. INDOOR UNIT : AS G07LMCA AS G09LMCA
More informationAUXG18LRLB AUXG24LRLB UTG-UKYA-W AOYG18LBCA AOYG24LBCA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) CONTENTS
SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit AUXG8LRL AUXGLRL UTG-UKYA-W Outdoor unit AOYG8LCA AOYGLCA CONTENTS SPECIFICATIONS.................... DIMENSIONS....................... REFRIGERANT
More information