Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

Size: px
Start display at page:

Download "Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW"

Transcription

1 0Hz Heat Pump Inverter Single Phase.kW to 8.0kW turn to the experts Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal capacity are available from.kw through 8.0kW to meet the needs of residential applications. CERTIFICATION: All models are registered with MEPS. ELECTRICAL RANGE Units offered in single phase 0V ~ 40V. ENVIRONMENTAL REFRIGERANT The uses R410a, the environmentally sound refrigerant that provides home owners with additional peace of mind because R410a has zero ozone--depletion potential. UNIT DESIGN: The copper tube(i-g), coated fin, enhanced sine wave, aluminum fin coil is designed for optimum heat transfer and corrosion protection. The sereis 0 Hz Split--System of inverter Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. These heat pump systems provide economy of operation through energy conservation when used with components designated by the manufacturer. The series recovers heat for indoor comfort from outdoor air during the heating season and, by automatically reversing the refrigerant system, remove indoor heat and excess humidity during the cooling season. SOUND SHIELD All ODU have compressor sound SHIELD for noise attenuation. OPERATING RANGE: Minimum outdoor operating ambient in cooling mode is -10 C, and maximum is 48 C. Minimum outdoor operating range for heating mode is -1 C, maximum is 4 C. HIDDEN DISPLAY The lights can be turned off by remote controller when the unit is running. -WAY DRAINAGE CONNECTION Both left and right sides of indoor unit are possible for drainage hose connection, easy for installation. LOUVER POSITION MEMORY When starting the unit again after shutting down, its louver will restore to the angle originally set by the user. 1

2 FEATURES AND BENEFITS ( CONT.) REFRIGERANT LEAKAGE DETECT (1)Only be active in cooling mode. ()If the refrigerant have leakage, the display area will show EC and AC will turn off. (3)The refrigerant leakage detect function can better prevent the compressor being damaged by refrigerant leakage or compressor overload. 8 HEATING (1)In heating operation, the preset temperature of the air conditioner can be as lower as 8, which keeps the room temperature steady at 8 and prevents household things freezing when the house is unoccupied for a long time in severe cold weather. ()This function can be memorized if the power fails. QUIET DESIGN Select SILENCE on remote controller to enter silence operation.(press the button for second). Indoor fan will run at super breeze, which can keep indoor in a very low noise level, make a comfortable feeling for sleep. FOLLOW ME ( 1) With this function, the room temperature sensor built in remote controller is activated and replaces the one in indoor unit. Then the air conditioner will regulate the room temperature based on the temperature around the remote controller, just like the air conditioner is following the user. ()Pressing the Follow me button on remote controller to active this function. Then the remote controller will send PCB the signal every three minutes. If the PCB doesn t receive the signal for 7 minutes or pressing Follow me button again, the follow me function will terminate. LOW AMBIENT COOLING The outdoor fan speed can be changed according to the condenser temperature and the AC can run smoothly under the temperature as low as -10. PRODUCT NUMBER NOMENCLATURE 4 / 38 Q H F IDU 38 - ODU Nominal Capacity Platform name H - Split and Wall Mounted K - Cooling only Q - Heat pump and cooling

3 PART NAMES Parts list Part No. Name of Part Qty 1 Indoor Unit 1 Mounting Screw A ST3.9x -C-H 1 3 Mounting Plate 4 Anchor Air Filter 1 6 Remote Control 1 7 Mounting Screw B ST.0x10 -C-H 1 8 Remote Control Holder 9 Outdoor Unit 1 Indoor 8 Outdoor 9 Display symbols OPERATION TIMER PERIOD SELECTION PREHEAT OR DEFROST IN PROGRESS SELECTED TEMPERATURE SELF-DIAGNOSTIC CODES 3

4 REMOTE CONTROLLER Buttuns 1. Temp Up / Temp Down Buttons. Mode Button 3. On/ Off Button 4. Horizontal Swing ( ) Button. Self Clean Button 6. Follow Me Button 7. Fan Button 8. Timer On( ) / Timer Off ( ) Buttons 9. Sleep Button 10. Turbo Button / Silence Button 11. LED Button / F. P Button NOTE: Vertical Swing ( ) are not available on this model. Remote control display 1. OPERATING MODE DISPLAY: Indicates the current operation mode AUTO, COOL, DRY, HEAT (heat pumps only), or FAN.. TRANSMISSION INDICATOR: Illuminates when remote control transmits signals to the indoor unit. 3. TEMPERATURE/TIMER DISPLAY: Temperature setting from 17 C to 30 C) or set times for the timer operation (0~4h) will be displayed. If FAN mode is selected, there will be no temperature displayed. 4. ON/OFF INDICATOR: This symbol appears when the unit is turned on by the remote control, and disappears when the unit is turned off.. FAN MODE DISPLAY: Indicates when fan mode is selected. 6. FAN SPEED DISPLAY: Indicates the set fan speed. Nothing is displayed when the mode is set to AUTO or DRY. 7. FOLLOW ME DISPLAY: This indicator will be displayed when the remote sensing function is activated. This option is not available in DRY and FAN modes. 8. TIMER DISPLAY: Indicates the timer settings. It displays TIMER ON when the auto--on time function is set, TIMER OFF when the auto--off time function is set, and TIMER ON OFF when both functions are set. 4

5 SPECIFICATION Model Number - System - Indoor - Outdoor Refrigerant Type Power Supply R410A R410A R410A Volts-Phase-Hz 0-40V~, 1Ph, 0Hz 0-40V~, 1Ph, 0Hz 0-40V~, 1Ph, 0Hz Capacity - Rated (Range) Kw.0(1.~3.0) 3.60(1.40~4.40) 4.89(1.60~.30) Cooling Power Input - Rated (Range) Kw 0.61(0.30~1.1) 0.88(0.3~1.0) 1.44(0.40~1.80) Efficiency - Rated (Range) EER 4.10(3.00~4.0) 4.10(3.60~4.70) 3.40(.90~4.40) Operating Current (Range) A.8(1.4~.3) 3.9(1.6~.4) 6.4(1.8~8.0) Capacity - Rated (Range) Kw.70(1.10~4.00) 3.80(1.10~4.80).0(1.40~6.00) Heating Powr Input - Rated (Range) Kw 0.68(0.30~1.0) 0.9(0.30~1.60) 1.6(0.40~.00) Efficiency - Rated (Range) COP 4.00(.70~4.0) 4.00(3.10~4.60) 3.40(3.00~4.60) Operating Current (Range) A 3.1(1.3~6.7) 4.(1.3~7.1) 7.1(1.8~8.8) Dimension (WxDxH) mm 800x188x7 940x0x7 940x0x7 Net Weight kg Cooling Airflow (Turbo/H/M/L) L/s 17/161/139/114 /03/17/16 /11/178/18 Indoor Unit Moisture Removal L/hr Cooling - (Sound Pressure) (H/M/L) - 1m dba (@spl) 41/37/33 44/41/38 44/41/38 Cooling Sound Power (H) Outdoor Unit Heating- (Sound Pressure) (H/M/L) - 1m dba (@spl) 41/37/33 44/41/38 44/41/38 Heating - (Sound Power) (H) dba (@swl) Dimension (WxDxH) mm 780x0x40 810x310x8 810x310x8 Net Weight kg Compressor Type Rotary Rotary Rotary Fan Motor Output W Cooling - (Sound Pressure) (H) at 1m distance dba (@spl) 6 7 Cooling Sound Power (H) Cooling Usable Temperature Range 0 C -10~48-10~48-10~48 Heating Usable Temperature Range 0 C -1~4-1~4-1~4 Liquid Line Ø/Gas Line Ø mm/inch 6.3/9. / 1/4"/3/8" 6.3/1.7 / 1/4"/1/" 6.3/1.7 / 1/4"/1/" Pipe Size Coupler Style flaring flaring flaring Drain (Inside Diameter) Ø mm Minimum Length m Maximum Length m 0 0 Chargeless Length m Additional Refrigerant Gm / m 1 1 1

6 SPECIFICATION (CONT.) Model Number - System - Indoor - Outdoor Refrigerant Type Power Supply R410A R410A R410A Volts-Phase-Hz 0-40V~, 1Ph, 0Hz 0-40V~, 1Ph, 0Hz 0-40V~, 1Ph, 0Hz Capacity - Rated (Range) Kw.93(1.80~6.70) 6.30(1.8~6.90) 8.00(3.40~8.0) Cooling Power Input - Rated (Range) Kw 1.80(0.0~.40) 1.91(0.~.30).3(0.80~.70) Efficiency - Rated (Range) EER 3.30(.80~4.00) 3.30(3.00~3.90) 3.40(3.10~4.40) Operating Current (Range) A 7.9(.~10.) 8.6(.~10.3) 10.4(3.6~1.0) Capacity - Rated (Range) Kw 6.0(1.60~7.10) 7.40(1.70~7.60) 9.00(3.10~9.90) Heating Powr Input - Rated (Range) Kw 1.97(0.0~.0).4(0.0~.40).0(0.80~3.10) Efficiency - Rated (Range) COP 3.30(.90~4.0) 3.30(3.00~4.10) 3.60(3.0~4.80) Operating Current (Range) A 8.7(.~11.0) 9.8(.~10.) 11.1(3.6~13.8) Dimension (WxDxH) mm 104x3x31 104x3x31 160x83x363 Net Weight kg Cooling Airflow (Turbo/H/M/L) L/s 333/319/67/36 333/319/67/36 389/37/300/6 Indoor Unit Moisture Removal L/hr Cooling - (Sound Pressure) (H/M/L) - 1m dba (@spl) 0/4/4 1/46/4 1/4/39 Cooling Sound Power (H) Outdoor Unit Heating- (Sound Pressure) (H/M/L) - 1m dba (@spl) 0/4/4 1/46/4 1/4/39 Heating - (Sound Power) (H) dba (@swl) Dimension (WxDxH) mm 84x30x x31x x31x860 Net Weight kg Compressor Type Twin Rotary Twin Rotary Twin Rotary Fan Motor Output W Cooling - (Sound Pressure) (H) at 1m distance dba (@spl) Cooling Sound Power (H) Cooling Usable Temperature Range 0 C -10~48-10~48-10~48 Heating Usable Temperature Range 0 C -1~4-1~4-1~4 Liquid Line Ø/Gas Line Ø mm/inch 9./1.9 / 3/8"//8" 9./1.9 / 3/8"//8" 9./1.9 / 3/8"//8" Pipe Size Coupler Style flaring flaring flaring Drain (Inside Diameter) Ø mm Minimum Length m Maximum Length m Chargeless Length m Additional Refrigerant Gm / m

7 HEAT PUMP HEATING PERFORMANCE 160% 140% 10% Vs Rating Capacity % 100% 80% 60% 40% % 0% Condenser Coil Entering Air Temperature 10% 100% 80% Vs Rating Capacity % 60% 40% 0% % Condenser Coil Entering Air Temperature 7

8 HEAT PUMP HEATING PERFORMANCE (CONT.) 10% 100% 80% Vs Rating Capacity % 60% 40% 0% % Condenser Coil Entering Air Temperature Note: Test mode: High fan speed and free frequency, inside condition(d/w) 0.0 / /6.0 is the rated heating test condition;.0 /1.0 is the defrost test condition /-8.0 is the minimum heating test condition from ISO standard; /-11.0 is the minimum heating test condition from Carrier standard. PHYSICAL DATA UNIT SIZE/SERIES SHIPPING WT (kg) OPERATING WT(kg) IDU IDU ODU ODU COMPRESSOR Rotary REFRIGERANT Type Control Puron (R410A) Capillary Charge (kg) FAN IDU Cross Type,Direct Drive ODU Propeller Type, Direct Drive MOTOR DRIVE IDU AC DC ODU DC AC DC 8

9 ELECTRICAL DATA MODEL VPH / OPERATING VOLTS* COMPRESSOR Max Min MODEL RLA INDOOR FAN MOTOR MODEL FLA OUTDOOR FAN MOTOR MODEL FLA MRC MAX FUSE** OR CKT BKR AMPS 0 ASN98DUFZ.3 RPG0E 00. WZDK36-38G-W ASN98DUFZ.3 RPG8D 06. WZDK40-38G-W / DA130M1C-31FZ 3.9 RPG8D 06. WZDK40-38G-W DA10S1C-0FZ 970. RPG4C 0.3 YDK3-6F DA10S1C-0FZ RPG4C 03. YDK100-6T DA0SC-30MT 8. 8 WZDK8-38G 046. WZDK7-38G * Permissible limits of the voltage range at which the unit will operate satisfactorily ** Time --- Delay fuse. FLA --- Full Load Amps MRC --- Maximum Running Current RLA --- RatedLoadAmps CONNECTION DIAGRAMS CONNECTING CABLE OUTDOOR TO INDOOR 0-40V~,1Ph,0Hz FIELD POWER SUPPLY GND W 1(L) (N) S GND W 1(L) (N) S L N Indoor Unit Power Supply 0-40V~/1Ph/0Hz Indoor Signal High Voltage Ground IDU TERMINAL BLOCK Power to Indoor Unit 0-40V~/1Ph/0Hz Indoor Signal High Voltage Main Power Supply 0-40V~/1Ph/0Hz ODU TERMINAL BLOCK Notes: 1. Do not use thermostat wire for any connection between indoor and outdoor units.. All connections between indoor and outdoor units must be as shown. The connections are sensitive to polarity and will result in a fault code. 9

10 UNITS INSTALLATION 0cm or more 10

11 4 4 B B 6 Air freshening filter(1) (used to install on Air filter) The holes for fixing anchors should be mm. C D Indoor unit outline Left rear side refrigerant pipe hole φ6 A Right rear side refrigerant pipe hole φ6 40 :(A:800, B:7, C:100, D:9) C D Indoor unit outline Left rear side refrigerant pipe hole φ6 A 4036 / 400: (A:940, B:7, C:110, D:100) Right rear side refrigerant pipe hole φ6 11

12 4 B C Installation plate D Indoor unit outline 1. Left rear side refrigerant pipe hole φ6 A 4060 / 406 : (A:104, B:31, C:93, D:163) Right rear side refrigerant pipe hole φ6 C D Indoor unit outline B Left rear side refrigerant pipe hole φ6 A Right rear side refrigerant pipe hole φ6 4080: (A:19, B:36, C:17, D:7) IDU Dimension H W D Model W D H / /

13 Model / / x40x40 810x310x8 84x30x x31x Wire cross section is depending on the rated (max) current which is indicated as below: 13

14 Model 0 / / Rated (max) current of appliance (A) Indoor Wire Connection 1.Lift the indoor unit front panel..remove the indoor unit electrical cover and cord clamp by loosening the screws. 3.Pass the connecting wires from the back of indoor unit and connect to the indoor terminal block. Outdoor Wire Connection 1. Remove the electrical cover and cord clamp by loosening the screws.. Connect wires to the outdoor terminal block by same sequence to indoor unit. Connection Diagrams Power supply from outdoor W 1 (N) S W 1 (N) S L N For all family Power supply 14

15 S INDOOR WIRING DIAGRAM M SWING MOTOR1 WHITE INDOOR UNIT JX1 OUTDOOR UNIT CN M SWING MOTOR 3() IN FAN C_ C_1 FAN CAPACITOR BOARD KEY BOARD BLACK/BLUE CN11 L-IN AC-N CN16 CN6 CN4 L-OUT RY1 3 P_1 CN14 CN8 CN9 PLASMA 1 3 BLUE BLACK OLP TEMP. SENSOR HEATER : ION CN 41 COMPRESSOR U V W EXPANSIVE VALVE 6() CN 36 CN 31 CN 30 CN 3 CN CN 1 CN 4 4-WAY BLUE BROWN CN13_1 CN13_ 3 4 MULTI-FUCTION CONTROL BOX CN10A 8 DISPLAY BOARD CN3(CN301) CN-KEY Wire Contoller ROOM TEMPERATURE SENSOR PIPE TEMPERATURE SENSOR RFMOD (Wi-Fi Contoller) BLACK : CN 1 CN 0 BLACK REACTOR R100(R003) CN 40 CN 4 : CN 3 W NOTE:Four-way valve is used in the Cooling & Heating unit only 1(L)(N) S L N POWER SUPPLY OUTDOOR FAN HEATER 1 HEATER : HEATER OUTDOOR WIRING DIAGRAM CN44 WIRING DIAGRAMS AMBIENT SENSOR (WHITE) DISCHARGE SENSOR M ~ HEAT EXCHANGER SENSOR (BLACK) U V W W (N) 1(L) S CN1_1CN1_ BLUE L N CN 3 Wiring diagram 4/380 4/ /3800 1

16 AC FAN WIRING DIAGRAMS (CONT.) SWING MOTOR INDOOR WIRING DIAGRAM M M M ELECTRONIC EXPANSIVE VALVE VERTICAL SWING MOTOR TO OXYGEN ENRICHMENT OR ANION GENERATOR (ELECTRONIC HEATER) RELAY ASSISTANT BOARD C_1 C_ CN1_COMP CN_COMP N.O. COM BLACK BLACK CT WHITE A CN14 LOW/HIGH : CN CN10 WHITE ION CN_N3 CN_HEAT Or CN4 CN_N CN8 Or Or CN_N CN_ION 4 BLUE BROWN BLACK OUTDOOR WIRING DIAGRAM HIGH PRESSURE PROTECT : LOW PRESSURE PROTECT BLUE OUTDOOR AMBIENT TEMPERATURE SENSOR CN17 CN18 CN6 CN4 M ~ CONDENSER TEMPERATURE SENSOR DISCHARGE SENSOR OUTDOOR FAN 3 () CN11 CN1 CompTop : T4 T3 N-OUT L-OUT CN7 MAIN BOARD ON(4) CN4 CN COM(3) RY CN9 PLASAM MAIN BOARD 3 CN1 ~ ~ CN1 INDOOR MOTOR MIRCO SWITCH 1 1 CN13 IPM BOARD CN8 WHITE CNL CN10 U V W CN CN3 CN CN_TIN CN_TO CNN CN_S BLUE(BLACK) 1()3(4) 1()3(4) (4) CN30 L-IN N-IN CN3 CN4 GND P-1(P-) CN CN3 Notes: This symbol indicates the element is optional,the actual shape shall be prevail. BLUE BLACK FAN CAPACITOR HEAT CN9 CN8 HEAT1 CN6 CN 4-WAY CN1 CN S BLUE BLUE W 1(L) (N) S INDOOR UNIT T1_room T_pipe TRANSFORMER REACTOR BOARD DISPLAY POWER BOARD BLUE HEATER HEATER1 4-WAY V(S) W(C) U(R) 1(L)(N) S L N W COMPRESSOR L N POWER SUPPLY Wiring diagram 4/ /

17 WIRING DIAGRAMS (CONT.) Wiring diagram 4/38080 INDOOR WIRING DIAGRAM M S ROOM TEMPERATURE SENSOR PIPE TEMPERATURE SENSOR SWING MOTOR1 WHI T E BLUE(BLACK) INDOOR UNIT JX1 OUTDOOR UNIT M (10) SWING MOTOR HEATER W (N) S 1(L) ION IN FAN M CN1_1 CN1_ CN6_1 CN4 P_1 CN CN14 CN6_ L-OUT L-IN N CN11(CN1) CN16 RY1 CN10A ( CN 10) MULTI-FUCTION CONTROL BOX 8(7) DISPLAY BOARD MICRO SWITCH PLASMA CN43 CN44 CN8 CN9 Wire Contoller DC FAN CT1 CN1 BLUE BLACK L-IN N-IN CN3 CN4 ELECTRONIC EXPANSIVE VALVE A CN7 CN17 N-OUT ON(4) RY COM(3) CN1 CompTop CN14 LOW/HIGH MAIN BOARD T4 T3 U V W GND P-1 DISCHARGE SENSOR 4 BLACK OUTDOOR WIRING DIAGRAM CN1 LOW PRESSURE PROTECT HIGH PRESSURE PROTECT CN CN3 CN4 CN ~ ~ IPM BOARD BLUE BLUE BLUE L-OUT CN38 CN37 CN6 CN11 CN1 REACTOR V(S) W(C) U(R) COMPRESSOR CN39 BLUE 4-WAY CN1 CN HEAT1 CN6 CN HEAT CN9 CN8 CN18 S CN10 OUTDOOR AMBIENT TEMPERATURE SENSOR CONDENSER TEMPERATURE SENSOR BLUE 4-WAY HEATER1 HEATER NOTE: As the standby control needs, the cross section area of cable connected to W, 1(L), (N) must be selected to suit the maximum system current. The maximum system current is equal to thesum of indoor unit and outdoor unit rated current. W 1(L)(N) S L N L N POWER SUPPLY 17

18 TROUBLESHOOTING For ease of service, the systems are equipped with diagnostic code display LEDs on both the indoor and outdoor units. The outdoor diagnostic display is two LEDs (Red and Green) on the outdoor unit board and is limited to very few errors. The indoor diagnostic display is a combination of flashing LEDs on the display panel or the front of the unit. If possible, always check the diagnostic codes displayed on the indoor unit first. The diagnostic codes displayed in the indoor and outdoor units are listed in the tables below. Operation lamp Timer lamp Display LED STATUS 1 time X E0 Indoor unit EEPROM parameter error times X E1 Indoor / outdoor units communication error 3times X E Zero crossing signal detection error 4 times X E3 Indoor fan speed has been out of control times X E4 6times X E Open circuit or short circuit of indoor room temperature T1 sensor Open circuit or short circuit of evaporator coil temperature T sensor 7 times X EC Refrigerant Leakage Detection 1time O E0 Current overload protection times O F1 Open circuit or short circuit of outdoor ambient T4 temperature sensor 3times O F Open circuit or short circuit of condenser coil temperature T3 sensor 4times O F3 Open circuit or short circuit of compressor discharge T temperature sensor times O F4 Outdoor unit EEPROM parameter error 6 times O F Outdoor fan speed has been out of control 1times P0 IPM malfunction or IGBT over-strong current protection times P1 Over voltage or over low voltage protection 3times P High temperature protection of compressor top diagnosis and solution times P4 Inverter compressor drive error = Flashing, X = Off O = Light For additional diagnostic information, refer to the Service Manual 18

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless System Sizes 09 to 36 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only. Actual models

More information

Hi - Wall Split Systems 12K - 18K - 24K

Hi - Wall Split Systems 12K - 18K - 24K R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic

More information

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE040427 Models TAC-07CS/K TAC-09CS/K TAC-2CS/K TAC-8CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-2CHS/K TAC-8CHS/K TAC-24CHS/K CONTENTS. IMPORTANT

More information

Ducted inverter reverse cycle air conditioning

Ducted inverter reverse cycle air conditioning Ducted inverter reverse cycle air conditioning What is ducted inverter reverse cycle air conditioning? Ducted inverter reverse cycle air conditioning is an ideal solution for whole-of-home or office cooling

More information

CAUTION DLFEHA. SERVICE MANUAL High Wall Ductless System Sizes 09 to 24

CAUTION DLFEHA. SERVICE MANUAL High Wall Ductless System Sizes 09 to 24 DLFEHA SERVICE MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 MODEL/SERIAL NUMBER NOMENCLATURES... 2 SPECIFICATIONS COOLING ONLY...

More information

Installation Instructions

Installation Instructions 40MAQ / 38MAQ 619PB / 538PR High---Wall Ductless Split System Sizes 09 to 30 Installation Instructions TABLE OF CONTENTS PAGE PARTS LIST... 2 SAFETY CONSIDERATIONS... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS...

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing. R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification

More information

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS Aurora Wall Split Systems. Built for one of the harshest climates on Earth. Aurora Wall Split Systems The leading Australian owned air conditioning

More information

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS Aurora Wall Split Systems. Built for one of the harshest climates on Earth. Aurora Wall Split Systems The leading Australian owned air conditioning

More information

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump 0-40V ~ 0Hz Ph 80-40V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump - 8-4 - 0 - - 48-0 DC Inverter Inverter Technology $ Efficient

More information

Service Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM

Service Manual.   Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM Service Manual Multi Split Type Heat Pump Air Conditioners Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM CONTENT 1. Product features 2. Specification 3. Dimensions 4. Refrigeration cycle

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES: 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons Product Data The 50 Hertz Outdoor Sections of Split-System Heat Pumps are designed for quiet, reliable heating during the winter

More information

Installation, Operation & Maintenance

Installation, Operation & Maintenance Installation, Operation & Maintenance Contura 5G Series R410a High Ambient & High Efficiency MS-SVX041A-EN 1 Contents 1. Precaution 1.1 Safety Precuation 03 1.2 Warning 03 2. Product Specifications 06

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...

More information

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. 02 - The Perfect Climate Kaden Wall Mounted Air Conditioners Creating the perfect climate in your home is essential for your family s comfort. Kaden

More information

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18 Submittal Sheet Submitted for: Approval Record Job Name: Contractor: Engineer: Date: Location: Tag: AIR-CON MULTI-SPLIT II Indoor Units Outdoor Unit High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

More information

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS SERVICE MANUAL MULTI COMBI OUTDOOR AND INDOOR UNITS CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS (36k,42k) COMBINATION TABLE (unit: kw) MC-E18AI MC-E24AI MC-E28AI MC-E36AI 1 model 2 models 2 models

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 8MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 0, 6 and 48 Fig. 1 18K Fig. 2 24K and 0K Product Data INDUSTRY LEADING FEATURES / BENEFITS A competitively priced and creative solution to design

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by Multi Split Systems Reverse Cycle, Inverter Air Conditioner Exclusively distributed by AUS 13 23 50 www.lennoxaus.com.au NZ 0800 653 330 www.lennoxnz.co.nz 1 As a global leader in comfort solutions, Lennox

More information

Service Manual CAUTION ! WARNING INTRODUCTION. 619PB High Wall Ductless System Sizes 09 to 36

Service Manual CAUTION ! WARNING INTRODUCTION. 619PB High Wall Ductless System Sizes 09 to 36 619PB High Wall Ductless System Sizes 09 to 36 Service Manual TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 MODEL/SERIAL NUMBER NOMENCLATURES... 2 SPECIFICATIONS... 3 COMPATIBILITY...

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL

More information

Wall Split System Air Conditioning

Wall Split System Air Conditioning Wall Split System Air Conditioning Comfort you can depend on. The perfect combination of stylish good looks and efficient performance. These systems are designed to keep you comfortable all year round.

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (1132718-M) WALL MOUNTED SPLIT UNIT LOMO N Series WALL MOUNTED SPLIT UNIT R410A Eco-friendly Refrigerant Quiet Fast Cooling

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

Installation Instructions

Installation Instructions 40MHH High Wall Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes only. Actual

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Ducted Systems About Toshiba s Ducted systems. Combining high power with high efficiency. Toshiba s Ducted systems allows you to air The Toshiba Air Conditioning DC Hybrid. The

More information

WALL MOUNTED UNITS SDH W SDH W SDH W SDH W

WALL MOUNTED UNITS SDH W SDH W SDH W SDH W WALL MOUNTED UNITS Technical Dossier WALL MOUNTED UNITS SDH 14-026 W SDH 14-036 W SDH 14-051 W SDH 14-065 W 2010 1- CONTENTS 1- Contents... 2 2- Technical specifications... 3 3- Temperature by capacities...

More information

Service Manual for TAS-18EHN, TAS-24EHN

Service Manual for TAS-18EHN, TAS-24EHN Service Manual for TAS-18EHN, TAS-24EHN CONTENTS 1. Precaution... 3 1.1 Safety Precaution... 3 1.2 Warning... 3 2. Function... 7 3. Dimension... 8 3.1 Indoor Unit... 8 3.2 Outdoor Unit... 10 4. Refrigerant

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. R COOL EER 0V ~ 50Hz 1Ph HEAT COP Heat Pump High Wall Split Systems 1K - 18K - 4K 0K - 6K Plasma Green Plasma Green Technology 1K-18K-4K Tropical Compressor

More information

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B INVERTER SPLIT-TYPE ROOM AIR CONDITIONER User and Remote Control Manual Read This Manual Inside

More information

C&H NORDIC Commercial 4 SERVICE MANUAL

C&H NORDIC Commercial 4 SERVICE MANUAL C&H NORDIC Commercial 4 SERVICE MANUAL CONTENTS PRODUCT...3 1 MODELS LIST... 3 1.1 Outdoor Unit.... 3 1.2 Indoor Unit.... 4 2 PRODUCT DATA.... 5 2.1 Product Data of Indoor Unit... 5 2.2 Operation Range...

More information

SUPER DC INVERTER MULTI TYPE INSTRUKCJA SERWISOWA

SUPER DC INVERTER MULTI TYPE INSTRUKCJA SERWISOWA ODMFI-B-1211 INSTRUKCJA SERWISOWA SUPER DC INVERTER MULTI TYPE K2OD-14HFN1-Q, K2OD-18HFN1-Q, K3OD-21HFN1-Q K3OD-27HFN1-Q, K4OD-28HFN1-Q, K4OA-36HFN1-Q K5OC-36HFN1-Q DC MULTI OUTDOOR UNITS CONTENTS 1. General

More information

DUCTED. SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. fordanddoonan.com.au 1800 AIR CON

DUCTED. SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. fordanddoonan.com.au 1800 AIR CON * H E A T I N G & C O O L I N G DUCTED SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. Mobile device not included * Terms and Conditions apply. See back cover for details.

More information

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Internal Condensate

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (3278-M) BORA Series WALL MOUNTED SPLIT UNIT NON-INVERTER Series Concealed display Hidden temperature display on a classy

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump 0-0V ~ 0Hz Ph 0-0V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Ducted Split System Heat Pump - - - 0 - - - 0 DC Inverter Inverter Technology $ Operation Hydrophilic Aluminum Fins Independent

More information

Service Manual CAUTION. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 ! WARNING SAFETY CONSIDERATIONS

Service Manual CAUTION. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 ! WARNING SAFETY CONSIDERATIONS 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 MODEL/SERIAL NUMBER NOMENCLATURES... 2 SPECIFICATIONS... 3 DIMENSIONS...

More information

INVERTER DUCTED SYSTEMS

INVERTER DUCTED SYSTEMS INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About

More information

Q Series. Inverter Split Systems

Q Series. Inverter Split Systems Q Series Inverter Split Systems Creating comfort in the home. Australians have been enjoying the comfort, convenience and reliability of Rinnai household appliances in their homes for over 40 years. Our

More information

Service Manual CAUTION

Service Manual CAUTION 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Service Manual TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 MODEL/SERIAL NUMBER NOMENCLATURES... 2 SPECIFICATIONS...

More information

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit. SERVICE MANUAL Indoor unit Outdoor unit 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* INDEX PART1 GENERAL INFORMATION PART2 ELECTRICAL DIAGRAM PART3 TROUBLE

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

PRODUCT LINE-UP Residential & Light Commercial air conditioners

PRODUCT LINE-UP Residential & Light Commercial air conditioners PRODUCT LINE-UP Residential & Light Commercial air conditioners Carrier air conditioning Energy savings Maximum energy savings thanks to accurate digital power control and super-efficient compressor. Comfort

More information

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

HI-WALL SPLIT SYSTEMS

HI-WALL SPLIT SYSTEMS HI-WALL SPLIT SYSTEMS What you ll find inside: Technology Digital Inverter range Controllers Product specifications Effective air filtration Energy efficient Heating & cooling 1 Toshiba Air Conditioning.

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

SERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS

SERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS SERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 6 3. Dimension... 7 3.1 Indoor

More information

Technical Manual. Multi Split Trio Quattro DCI REFRIGERANT R410A HEAT PUMP

Technical Manual. Multi Split Trio Quattro DCI REFRIGERANT R410A HEAT PUMP Technical Manual Multi Split Trio Quattro DCI Indoor Units WNG 9 DCI INV WNG 12 DCI INV WNG 18 DCI INV ECF 9 DCI INV ECF 12 DCI INV ECF 18 DCI INV PXD 9 DCI INV PXD 12 DCI INV PXD 18 DCI INV LS 35 DCI

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

Now with WiFi as standard Find out more at

Now with WiFi as standard Find out more at Floor Console Now with WiFi as standard Find out more at www.greeonline.com (SMPS model) Power Saving Technology GREE Sine-Wave DC Inverter technology allows a room to reach the required temperature more

More information

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8. Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule

More information

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units

SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units FS2MIF-140AE2 FS2MIF-180AE2 FS3MIF-210AE2 FS3MIF-270AE2 FS4MIF-280AE2 FS4MIF-360AE2 FS5MIF-360AE2 NOTE: Before servicing the unit,

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier Inverter Ducted Systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

Installation Instructions

Installation Instructions 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes

More information

Submittal Data Sheet

Submittal Data Sheet Submittal Data Sheet INDOOR UNIT OUTDOORE UNIT Model No. DIR-09AC17-DKI DIR-09AC17-DKO AS-09TR1SVDDA Type T1, INVERTER Performance Cooling Capacity Btu/h 9000 Heating Capacity Btu/h / Cooling Capacity

More information

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote

More information

Product Data. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 INDUSTRY LEADING FEATURES / BENEFITS 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 Product Data INDUSTRY LEADING FEATURES / BENEFITS A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT. The 38MAQ series ductless

More information

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB

More information

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Bosch Split-Type Ductless Air Conditioner / Heat Pump Bosch Split-Type Ductless Air Conditioner / Heat Pump Climate 5000 AA Series Service Manual 2 Bosch Climate 5000 AA Series Split Type Ductless Air Conditioner / Heat Pump Service Manual Data subject to

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become

More information

DuctlessAire ES Series. Service Manual 2016 ABSSA-B4-1601

DuctlessAire ES Series. Service Manual 2016 ABSSA-B4-1601 DuctlessAire ES Series Service Manual 2016 ABSSA-B4-1601 CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Model list... 4 3. Dimension... 5 3.1 Indoor Unit... 5 3.2 Outdoor Unit...

More information

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION. 38MA*R Outdoor Unit Single Zone Ductless System Sizes 09 to 36

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION. 38MA*R Outdoor Unit Single Zone Ductless System Sizes 09 to 36 38MA*R Outdoor Unit Single Zone Ductless System Sizes 09 to 36 Service Manual TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 MODEL / SERIAL NUMBER NOMENCLATURES... 2 SPECIFICATIONS...

More information

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM

More information

FAN COILS wall mounted

FAN COILS wall mounted SERVICE MANUAL FAN COILS wall mounted SF-51H, SF-68H, SF-85H PRODUCT MODELS LIST Model Name Cooling Capacity (W) Product Code Air Flow (m 3 /h) Power Supply (V,Ph,Hz) Remarks SF-51H 2700 EM55001260 550

More information

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) TECHNICAL MANUAL & PARTS LIST DRAFT INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK20ZD-S - 1 - INDOOR UNIT Model SRK20ZD-S OUTDOOR UNIT Model SRC20ZD-S REMOTE

More information

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE031229 Models TAC-07CS/K TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CSC/K TAC-09CSC/K TAC-12CSC/K TAC-18CSC/K TAC-24CSC/K TAC-07CHS/K

More information

Product Brochure 2017

Product Brochure 2017 Product Brochure 2017 2017 Brand Story The Internet era is a diverse and unconventional time, where one size fits all products and solutions simply aren t enough. Customers want to be treated as individuals

More information

Compact design & easy maintenance

Compact design & easy maintenance Compact design & easy maintenance 18 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice.

More information

KSIN INVERTER SERIES Service Manual 2013

KSIN INVERTER SERIES Service Manual 2013 KSIN INVERTER SERIES Service Manual 2013 CONTENTS 1. Precaution............ 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function............ 6 3. Dimension............ 8 3.1 Indoor Units... 8 3.2

More information

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette Leading edge reverse cycle air conditioning Ducted and ceiling cassette Seeley International never stops striving to innovate and build the world s most energy efficient heaters and air conditioners. The

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

SERVICE MANUAL. KSIO MINI Split DC Inverter Air Conditioner. Model Numbers:

SERVICE MANUAL. KSIO MINI Split DC Inverter Air Conditioner. Model Numbers: KSIO MINI Split DC Inverter Air Conditioner SERVICE MANUAL Model Numbers: KSIO009-H124-I KSIO012-H123-I KSIO018-H221-I KSIO024-H219-I KWIO09-H2 KWIO12-H2 Table of Contents 1. Precaution 2. Part Names And

More information

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF AOU 9RLFW AOURLFW R40A CONTENTS. DESCRIPTION OF EACH CONTROL OPERATION. COOLING

More information

Westinghouse. Split System Inverter Series. Service Manual

Westinghouse. Split System Inverter Series. Service Manual Westinghouse Split System Inverter Series Service Manual Model: WIWPK/WCHPK Range: 2.6kw 7.6kw CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 5 3. Dimension... 6

More information

Change for Life. Service Manual

Change for Life. Service Manual Change for Life Service Manual Models: GWH09QB-K3DNA1G GWH09QB-K3DNA2G GWH09QB-K3DNA5G GWH09QB-K3DNB2G GWH09QB-K3DNB4G GWH09QB-K3DNB6G GWH12QC-K3DNA1G GWH12QC-K3DNA2G GWH12QC-K3DNA5G GWH12QC-K3DNB2G GWH12QC-K3DNB4G

More information

Product Brochure Smart Power. Low Profile Ducted

Product Brochure Smart Power. Low Profile Ducted Product Brochure 2017 Smart Power Low Profile Ducted 2017 Brand Story The Internet era is a diverse and unconventional time, where one size fits all products and solutions simply aren t enough. Customers

More information

Installation Instructions

Installation Instructions 38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes

More information

Mission 3D Inverter Series

Mission 3D Inverter Series Mission 3D Inverter Series Service Manual 2014 MBSEU-A-1412 CONTENTS 1. Precaution... 3 1.1 Safety Precaution... 3 1.2 Warning... 3 2. Function... 6 3. Dimension... 7 3.1 Indoor Unit... 7 3.2 Outdoor Unit...

More information

Just feel well. 2017/2018 Air conditioning

Just feel well. 2017/2018 Air conditioning 1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

TROUBLESHOOTING TROUBLESHOOTING. Indoor unit EEPROM parameter error. Indoor / outdoor units communication error. Zero-crossing signal detection error

TROUBLESHOOTING TROUBLESHOOTING. Indoor unit EEPROM parameter error. Indoor / outdoor units communication error. Zero-crossing signal detection error www.olmo-comfort.com TROUBLESHOOTING When below list for identification of error code occurs, please turn off air conditioner and disconnect power, and then contact the qualified professionals for service.

More information

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307.

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307. WALL SPLIT-TYP WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS MOUNTED SERVICE MANUAL No.TE1307 Models: TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** CONTENTS: 1. IMPORTANT NOTICE 2. OPERATION DETAILS

More information

Table of Contents. Page. 1. Safety Precautions Specifications Product Features Maintenance and Disassembly...

Table of Contents. Page. 1. Safety Precautions Specifications Product Features Maintenance and Disassembly... Table of Contents Page 1. Safety Precautions... 1 1. In case of Accidents or Emergency 2. Pre-Installation and Installation 3. Operation and Maintenance 2. Specifications... 3 1. Model Reference 2. Electrical

More information