Owner s Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Size: px
Start display at page:

Download "Owner s Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER."

Transcription

1 Induced Combustion Gas Furnace NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. Owner s Manual CERTIFIED USER: Please read all instructions in the manual and retain all manuals for future reference. FIRE OR EXPLOSION HAZARD Failure to follow safety warnings could result in injury, death, or property damage. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS -Do not try to light any appliance. -Do not touch any electrical switch; do not use any phone in your building. -Leave the building immediately. -Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. -If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. A02182 CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in personal injury and/or death. Carbon Monoxide is invisible, odorless, and toxic! Bryant Heating and Cooling Systems recommends a carbon monoxide alarm in your home, even if you do not own a gas appliance. Locate the carbon monoxide alarm in the living area of your home and away from gas appliances and doorways to attached garages. Follow the alarm manufacturer s instruction included with the alarm. ELECTRICAL OPERATION HAZARD Failure to follow this warning could result in personal injury, death, or property damage. Do not use this furnace if any part has been under water. A flood -damaged furnace is extremely dangerous. Attempts to use the furnace can result in fire or explosion. A qualified service agency should be contacted to inspect the furnace and to replace all gas controls, control system parts, electrical parts that have been wet or the furnace if deemed necessary. 1

2 WELCOME TO TODAY S GENERATION OF COMFORT Congratulations! Your new, higher efficiency gas furnace is a sound investment which will reward you and your family with years of warm memories winter after winter. Not only is your new furnace energy efficient, it is also extremely reliable. Spend just a few minutes with this booklet to learn about the operation of your new furnace and the small amount of maintenance it takes to keep it operating at peak efficiency. Years went into the development of your new furnace. Take a little time now to assure its most efficient operation for years to come. TABLE OF CONTENTS WELCOME TO A NEW GENERATION OF COMFORT... 2 FURNACE COMPONENTS... 2 GENERAL FURNACE SAFETY... 2 IMPORTANT FACTS... 2 SAFETY CONSIDERATIONS... 3 BEFORE STARTING YOUR FURNACE... 3 STARTING YOUR FURNACE... 3 Steps for Starting Your Furnace... 4 SHUTTING DOWN YOUR FURNACE... 5 PERFORMING ROUTINE MAINTENANCE... 5 Filtering Out Trouble... 6 COMBUSTION AREA AND VENT SYSTEM... 7 BEFORE YOU REQUEST A SERVICE CALL... 8 REGULAR DEALER MAINTENANCE... 8 INSTALLATION DATA... 9 GENERAL FURNACE SAFETY 1. Combustible Materials, Gasoline Warning Furnace Must be Kept Free and Clear of Insulating Material Warning Furnace Needs Air for Combustion and Ventilation Warning Starting (Lighting) and Shutting Down the FurnaceWarning...4,5 5. DraftSafeguardSwitchCaution ProperFurnaceShutdownProcedures FloodDamageWarning Fire or Explosion Hazard Warning Carbon Monoxide Warning Service and Maintenance Electrical Hazard Warning ImproperVentWarning SharpEdgesCaution No Filter Caution Filter Rod Modification Caution Dirt,Rust,orAccumulationCaution...7 FURNACE COMPONENTS (Furnace shown in upflow position; may be used in downflow or horizontal orientation or applications. Vent Elbow may be turned to a different position, depending on type of installation) INDUCER MOTOR ASSEMBLY PRESSURE SWITCH FLUE COLLECTOR BOX GAS VALVE MANUAL RESET LIMIT SWITCHES HOT SURFACE IGNITER CONTROL RATING PLATE NOT SHOWN (LOCATED ON BLOWER DOOR) VENT ELBOW MAIN LIMIT SWITCH (BEHIND GAS VALVE) DRAFT SAFEGUARD SWITCH FLAME SENSOR GAS MANIFOLD GAS BURNER BLOWER DOOR SAFETY SWITCH BLOWER AND MOTOR CAPACITOR A02259 Fig. 1-80% AFUE Single Stage Furnace Components INDUCER MOTOR ASSEMBLY PRESSURE SWITCH FLUE COLLECTOR BOX GAS VALVE MANUAL RESET LIMIT SWITCHES HOT SURFACE IGNITER CONTROL RATING PLATE NOT SHOWN (LOCATED ON BLOWER DOOR) VENT ELBOW MAIN LIMIT SWITCH (BEHIND GAS VALVE) DRAFT SAFEGUARD SWITCH FLAME SENSOR GAS MANIFOLD GAS BURNER BLOWER DOOR SAFETY SWITCH BLOWER AND MOTOR CAPACITOR A02260 Fig. 2-80% AFUE Two -Stage Furnace Components 2

3 IMPORTANT FACTS (DO S AND DON TS) S DO: READ AND UNDERSTAND THIS MANUAL. S DO: Have your furnace and vent system inspected annually by a qualified service technician. S DO: Inspect your filter monthly and clean or replace when needed. S DO: Provide adequate airflow to the furnace for efficient combustion and safe ventilation. S DO: Keep your furnace free and clear of insulating material. Some materials may be combustible. Examine the furnace area when the furnace is installed or when insulation is added. S DO NOT: Enclose your furnace in an airtight room or seal it behind solid doors. S DO NOT: Keep combustible materials, gasoline, and other flammable liquids or vapors around your furnace. S DO NOT: Cover your furnace in any manner. S DO NOT: Store anything (including trash or debris) near your furnace. S DO NOT: In any way block or restrict airflow around your furnace. S DO NOT: In any way block or restrict airflow to your supply air and return air grills. S DO NOT: Use your furnace room as a broom closet or a place to store any kind of chemical or cleaner. S DO NOT: Contaminate the air used for combustion of your furnace with any kind of chemical or fumes. This could also cause heat exchangers, metal vent systems or components to deteriorate. NOTE: These chemicals or fumes are present in many products around the home, such as: water softener salts, any type of household cleaning product, any type of laundry product, adhesives, paints, varnishes, paint strippers, waxes and plastics, etc. During remodeling be sure the combustion air is fresh and uncontaminated. If these compounds are burned in your furnace, the heat exchangers and metal vent system may deteriorate. NOTE: The qualified installer or agency must use only factory -authorized replacement parts, kits, and accessories when modifying this product. This furnace contains safety devices which must be manually reset. If the furnace is left unattended for an extended period of time, have it checked periodically for proper operation. This precaution will prevent problems associated with no heat, such as frozen water pipes, etc. See Before You Request a Service Call section in this manual. ELECTRICAL OPERATION HAZARD Failure to follow this safety warning could result in injury, death, or property damage. Do not keep combustible materials, gasoline, and other flammable liquids or vapors around your furnace. FIRE OR EXPLOSION HAZARD Failure to follow safety warnings could result in personal injury, death, or property damage. Keep insulation clear of furnace and maintain clearances shown on unit clearance label. BEFORE STARTING YOUR FURNACE Examine the furnace installation to determine that: 1. All flue gas carrying areas external to the furnace (i.e. chimney, vent connector) are clear and free of obstructions. 2. The vent connector is in place, slopes upward and is physically sound without holes or excessive corrosion. 3. The return -air duct connection(s) is physically sound, is sealed to the furnace casing, and terminates outside the space containing the furnace. 4. The physical support of the furnace is sound without sagging cracks, gaps, etc. around the base. 5. There are no obvious signs of deterioration of the furnace. 6. The pilot and burner flames are in good adjustment (by comparison with pictorial sketches or drawings of the main burner flame and, if applicable, the pilot burner flame). SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components. Only trained and qualified personnel should install, repair, or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning or replacing air filters. All other operations must be performed by trained service personnel. Observe safety precautions in this manual, on tags, and on labels attached to the furnace, and other safety precautions that may apply. Recognize safety information. This is the safety -alert symbol. When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety -alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability or operation. 3

4 STARTING YOUR FURNACE Your furnace uses an automatic, hot surface ignition system to light the burners each time the thermostat signals the furnace to start. CLOSE Follow these important safeguards: S Never attempt to manually light the burners with a match or other source of flame. Fig. 5 - Close Valve 3. Turn OFF electrical supply to the furnace. A06188 S S Fig. 3 - Do Not Light Burner with Match A92319 Read and follow the operating instructions on inside of main furnace door, especially the item that reads as follows: Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow B in the safety information above on this furnace label. If you don t smell gas, go to the next step. If a suspected malfunction occurs with your gas control system, such as the burners do not light when they should, refer to the shutdown procedures on inside of main furnace door, or in the Shutting Down Your Furnace section and call your dealer as soon as possible. A92185 Fig. 6 - Turn Off Electrical Supply 4. Remove the outer door by loosening the thumbscrew and pulling the door forward. 1 2 FIRE AND EXPLOSION HAZARD Failure to follow this warning could result in personal injury, death or property damage. Should the gas supply fail to shut off or if overheating occurs, turn off the manual gas valve to the furnace BEFORE turning off the electrical supply and install lockout tag. S CHECK AIR FILTER: Before attempting to start your furnace, be sure the furnace filter is clean and in place. See Performing Routine Maintenance section in this manual. Do not run the furnace without a filter in place. Then proceed as follows: STEPS FOR STARTING YOUR FURNACE 1. Set your room thermostat to the lowest temperature setting. 3 A02073 Fig. 7 - Remove Furnace Door 5. Turn the control switch on the gas control to the OFF position and wait 5 minutes. Then smell for gas, including near the floor. If you smell gas, STOP! Follow B on furnace label. If you don t smell gas, go to next step. ON OFF OR Fig. 4 - Lowest Temperature Setting 2. Close the external manual gas valve. A08121 A02266 Fig. 8 - Control Switch to OFF 6. After waiting 5 minutes, if you still smell gas, STOP! Follow the safety information on the cover of this manual. If you do not smell gas, go to the next step. 7. Turn the control switch to ON. 4

5 OR ON OFF Fig. 9 - Control Switch to ON 8. Replace the outer door and tighten the thumbscrew Fig Furnace Door Replaced 9. Turn ON the electrical supply to the furnace. A02267 A Afterabout17 seconds,the gasvalve permitsgas to flow to the main burners where it is ignited. Hot flames begin to warm the furnace s heat exchanger. After a time delay of approximately seconds the furnace blower is switched on. NOTE: If the main burners fail to ignite, the furnace control system will go through three more ignition cycles. Then if burners fail to ignite, the system will lockout. If lockout occurs or the blower does not come on, shut down your furnace and call your dealer for service. 13. Set your thermostat to the temperature that satisfies your comfort requirements. SUGGESTION: Setting the thermostat back a few degrees and compensating for the difference with warmer clothing can make a big difference in your fuel consumption on extremely cold days. The few degrees at the top of your thermostat comfort level are the most costly degrees to obtain. When the room temperature drops below the temperature selected on the thermostat, the furnace will switch on automatically. When the room temperature reaches the setting selected on the thermostat, the furnace will be automatically switched off. Continuous Fan Operation -Some thermostats have a FAN switch with 2 selections: AUTO and ON. When thermostat is set on AUTO, the furnace blower cycles on and off, controlled by the thermostat. In ON position, the furnace blower runs continuously except for a sec delay at the call for heat. Continuous fan keeps the temperature level in your home more evenly balanced. It also continuously filters the indoor air. FanOnt - On all but the 310AAV or 310JAV, the continuous fan blower speed can be increased or decreased if desired due to change of seasons, large gatherings in your home, etc. Simply change your FAN switch from on to off (or auto depending on your thermostat), and then return to on, within 1 to 3 seconds. The blower will switch to the next highest speed. There are at least 3 speeds to choose from. If the blower is running on its highest speed, a request to change will direct the blower to return to its lowest speed. Fig Turn On Electrical Supply 10. Open the external manual gas valve. A92359 SHUTTING DOWN YOUR FURNACE Should you ever suspect a malfunction in your furnace, you will need to turn the furnace off. The following procedures must be followed: 1. Set your room thermostat to the lowest temperature setting. (See Fig. 3.) 2. Close the external manual gas valve (See Fig. 4). OPEN 3. Turn off electrical supply to the furnace. (See Fig. 5.) 4. Remove outer furnace door. (See Fig. 6.) 5. Turn the switch on the gas control to the OFF position. (See Fig.7.) A06189 Fig Open Valve 11. Set the room thermostat to a temperature slightly above the room temperature. This will automatically signal the furnace to start. The inducer motor will start and the hot surface igniter will energize. When hot, the igniter will have an orange glow. 6. Replace the outer furnace door. (See Fig. 9.) 7. If the furnace is being shut down because of a malfunction, call your dealer as soon as possible. 5

6 PERFORMING ROUTINE MAINTENANCE With proper maintenance and care, your furnace will operate economically and dependably. Instructions for basic maintenance are found on this and the following pages. However, before beginning maintenance, follow these safety precautions: ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Turn off electrical power supply to your furnace before removing the access doors to service or perform maintenance. Fig Turn Off Electrical Supply 2. Remove filter cabinet door (See Fig. 14 and 15.) NOTE: It may be necessary to remove 1 thumbscrew. A92185! CAUTION CUT HAZARD Failure to follow this caution may result in personal injury. Although special care has been taken to minimize sharp edges, be extremely careful when handling parts or reaching into the furnace. Wear safety glasses, gloves, and appropriate protective clothing. FILTERING OUT TROUBLE! CAUTION UNIT PERFORMANCE HAZARD Failure to follow this caution may result in product damage. Never operate your furnace without a filter in place. Doing so may damage the furnace blower motor. An accumulation of dust and lint on internal parts of your furnace can cause a loss of efficiency. Fig Removing Side Filter Cabinet Door A06190 A dirty filter will cause excessive stress on the furnace, heat exchanger, and blower motor and can cause it to overheat and automatically shut down. The furnace filter should be checked every 4 weeks and cleaned or replaced if necessary. If installed with factory specified disposable media filter, check or replace filter before each heating and cooling season. Replace disposable media filter at least twice a year. If your furnace filter needs replacing, be sure to use the same size and type of filter that was originally specified The air filter for the furnace may be located in a filter cabinet attached to the side or bottom of the furnace. If air filter has been installed in another location, contact your dealer for instructions. To inspect, clean and/or replace the air filter(s), follow these steps: 1. Turn off the electrical supply to the furnace. Fig Removing Bottom Filter Cabinet Door A Slide air filter out of filter cabinet. Keep dirty side up (if dirty) to avoid spilling dirt. (See Fig. 16 and 17.) 6

7 Fig Slide Side Filter Out of Furnace A00227 Fig Replace Side Filter Cabinet Door A06192 A00228 Fig Slide Bottom Filter Out of Furnace 4. Inspect the filter. If torn, replace it. NOTE: If a washable filter has been replaced with: a. Factory specified disposable media filter Do not clean. If dirty, replace only with media filter having the same part number and size. Install with airflow direction arrow pointing towards blower. b. Electronic Air Cleaner (EAC) Refer to EAC Owner s Manual for maintenance information. 5. Wash filter (if dirty) in sink, bathtub, or outside with a garden hose. Always use cold tap water. A mild liquid detergent may be used if necessary. Spray water through filter in the opposite direction of airflow. Allow filter to dry. 6. Reinstall clean air filter. 7. Replace filter cabinet door. (See Fig. 18 and 19.) 8. Turn on electrical supply to furnace (See Fig. 11). A06193 Fig Replace Bottom Filter Cabinet Door NOTE: If side return ducts are used, 2 filters may be required in some models. The procedure listed above may be used to remove side filters.! CAUTION PERSONAL INJURY HAZARD Failure to follow this caution may result in personal injury. Use care when cutting support rods in filters to protect against flying pieces and sharp rod ends. Wear safety glasses, gloves, and appropriate protective clothing. Filters may be field modified by cutting filter material and support rods (3) in filters. Alternate sizes and additional filters may be ordered from your dealer. FURNACE CASING WIDTH IN (MM) /2 (368) /2 (445) SIDE RETURN IN (MM) (1) 16 x 25 (406 x 635) (1) 16 x 25 (406 x 635) FILTER QUANTITY AND SIZE * ** BOTTOM RETURN IN (MM) (1) 14 x 25 (356 x 635) (1) 16 x 25 (406 x 635) FILTER TYPE* 1 (25 mm) thick cleanable or /16 (110 mm) thick media---type 1 (25 mm) thick cleanable or /16 (110 mm) thick media---type 21 (533 ) 24 (610) *Recommended **Some furnaces may have 2 filters (1) 16 x 25 (406 x 635) (1) 16 x 25 (406 x 635) (1) 20 x 25 (508 x 635) (1) 24 x 25 (610 x 635) 1 (25 mm) thick cleanable or 4---5/16 (100 mm) thick media---type 1 (25 mm) thick cleanable or /16 (100 mm) thick media---type 7

8 COMBUSTION AREA AND VENT SYSTEM ELECTRICAL OPERATION HAZARD Failure to follow this warning could result in personal injury or death. For proper and safe operation the furnace needs air for combustion and ventilation. Do not block or obstruct air openings on the furnace, air opening to the area in which the furnace is installed, and the space around the furnace. ELECTRICAL OPERATION HAZARD Failure to follow this warning could result in personal injury or death. If holes are found or if the vent pipe is obstructed or is not connected, toxic fumes can escape into your home. DO NOT OPERATE YOUR FURNACE. Call your dealer for service. Fig Burner Flame CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in personal injury or death. If dirt, rust, soot, or scale accumulations are found, call your dealer. Do not operate your furnace. A92330 Inspect the combustion area and vent system before each heating season. An accumulation of dirt, soot, or rust can mean a loss of efficiency and improper performance. Buildups on the main burners can cause faulty firing. This delayed ignition is characterized by an alarmingly loud sound. NOTE: If your furnace makes a loud noise when the main burners are ignited, shut down the furnace and call your servicing dealer. Use your flashlight and follow these steps for inspecting the combustion area and vent system of your furnace: 1. Turn off electrical supply to the furnace and remove the access door. (See Fig. 6 and 7.) 2. Carefully inspect the gas burner for dirt, rust, or scale. Inspect the elbow, flue connection area, and the vent pipe for rust. 3. Inspect the vent pipe for a sag, holes, or a disconnection. A horizontal vent pipe must slope upward away from furnace. If rusty joints or seams, or signs of water leakages are found, call your dealer for service. 4. Restore electrical power to the furnace. (See Fig. 11.) 5. Start the furnace and observe its operation. If possible, watch the burner flames. Are they burning bright blue? If not or if you suspect some other malfunction, call your servicing dealer. 6. Replace the access door. (See Fig. 10.) 8

9 BEFORE YOU REQUEST A SERVICE CALL Before you call for service, check for several easily solved problems: S Check for sufficient airflow. Check the air filter for dirt. Check for blocked return -air or supply -air grilles. Be sure they are open and unobstructed. If this isn t the cause of the problem, call your servicing dealer. If your furnace isn t operating at all, check the following list for easily solved problems: S Is your thermostat set above room temperature? Is the HEAT mode selected? S Is the electrical power supply switch on? Is the blower access door firmly in place? Are any fuses blown? (There is a fuse on the furnace control.) Has a circuit breaker tripped? S Is the manual shut-off valve in the gas supply pipe leading to the furnace open? Does the lever point in the same direction that the pipe runs (open)? Or is it at a right angle to the pipe (closed)? NOTE: Before proceeding with the next checks, turn off the electrical power supply to the furnace. Remove access door. S Is the switch on the gas valve turned to the ON position? If this or the preceding check shows an interruption in the gas supply, make sure the gas has not been shut off for safety reasons. If nothing else seems to be wrong, follow the start-up procedures found on pages 4 and 5 of this booklet.! CAUTION PERSONAL INJURY HAZARD Failure to follow this caution may result in personal injury. If for some reason the vent is blocked, the draft safeguard switch will shut off the furnace. (See Page 2 for switch location.) The switch will automatically reset after the furnace cools off. If the furnace fails to operate, contact a qualified service agency. S Check the manual reset limit switches located on the ends of the burner enclosure (see Fig. 1 and 2). If the furnace has experienced a high -temperature condition due to inadequate combustion air, these switches will shut off the furnace. Reset the switches by pushing the button on the switch. If the switch trips a second time, turn off the furnace and call for service. S If your furnace still fails to operate, call your servicing dealer for troubleshooting and repairs. Tell your dealer the model and serial numbers for your furnace. (You should have them recorded on page 10 of this booklet.) By knowing exactly which furnace you have, the dealer may be able to offer suggestions over the phone or save valuable time through knowledgeable preparation for the service call. Regular dealer maintenance In addition to the type of routine maintenance you might be willing to do, your furnace should be inspected regularly by a properly trained service technician. A semiannual inspection (or annual inspection, at least) should include the following: 1. Inspection of all flue gas passages including the burners, heat exchanger, inducer, elbow, and vent pipe. 2. Inspection of all combustion and ventilation air passages and openings. 3. Close check of all gas pipes leading to and inside of your furnace. 4. Inspection and cleaning of the blower motor and wheel. 5. Routine inspection and cleaning/replacement of the air filter. 6. Inspection of all supply - and return -air ducts for obstructions, air leaks, and insulation. Any problems found should be resolved at this time. 7. Inspection of furnace installation for proper support and any obvious deterioration of the furnace. The support must be sound and without sags, gaps, cracks, etc., around the furnace base so as to provide an air seal between the return -air duct and furnace. 8. A check for loose connections attaching individual components. Inspection of all electrical wiring and their connections. 9. Operational check of the furnace itself to determine working condition. Repair or adjustment should be made at this time. Ask your servicing dealer for further details about an economical service contract that covers seasonal inspections. 9

10 NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information will be helpful should your system require maintenance or service. FURNACE Model # Serial # AIR CONDITIONER OR HEAT PUMP Model # Serial # INDOOR COIL (Furnace Coil or Fan Coil) Model # Serial # INSTALLATION INFORMATION: Date Installed DEALERSHIP CONTACT INFORMATION: Company Name Address Phone Number Technician Name NOTE TO INSTALLER: This manual must be left with the equipment owner. Heating&CoolingSystems TO OBTAIN INFORMATION ON PARTS: Consult your installing dealer or classified section of your local telephone directory under the Heating Equipment or Air Conditioning Contractors & Systems heading for dealer listing by brand name. Have available the Model No., Series Letter, & Serial No. of your equipment to ensure correct replacement part. Copyright 2008 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indianapolis, IN Printed in the U.S.A. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10 Edition Date: 03/08 Catalog No: OM Replaces: OM

Owner s Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. Induced Combustion Gas Furnace Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: Please read all instructions in the manual and retain all manuals for future reference.

More information

HOME OWNER S INFORMATION Induced Combustion Gas Furnace

HOME OWNER S INFORMATION Induced Combustion Gas Furnace HOME OWNER S INFORMATION Induced Combustion Gas Furnace NOTE TO INSTALLER: This manual must be left with the equipment user. USER: Please read all instructions in the manual and retain all manuals for

More information

Owner's Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner's Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. Induced Combustion Gas Furnace Owner's Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.

More information

This document was created with FrameMaker 4.0.4

This document was created with FrameMaker 4.0.4 This document was created with FrameMaker.0. WELCOME TO TODAY S GENERATION OF COMFORT Congratulations! Your new, higher efficiency gas furnace is a sound investment which will reward you and your family

More information

GAS FURNACE. User's Information Manual for the operation and maintenance of model GB1AAV or GB3AAV Gas Furnace

GAS FURNACE. User's Information Manual for the operation and maintenance of model GB1AAV or GB3AAV Gas Furnace GAS URNACE User's Information Manual for the operation and maintenance of model GB1AAV or GB3AAV Gas urnace NOTE: This manual must be left with the equipment user. MODEL GB1AAV UPLOW URNACE WARNING: If

More information

NOTE TO INSTALLER: This manual must be left with the equipment user. Model 480BAV Upflow and 481BAV Downflow/Horizontal

NOTE TO INSTALLER: This manual must be left with the equipment user. Model 480BAV Upflow and 481BAV Downflow/Horizontal NOTE TO INSTALLER: This manual must be left with the equipment user. Model 0BAV Upflow and BAV Downflow/Horizontal USER S INORMATION MANUAL OR THE OPERATION AND MAINTENANCE O YOUR NEW GAS-IRED URNACE WARNING:

More information

MODELS 373LAV, 376CAV DOWNFLOW/HORIZONTAL and 383KAV, 395CAV UPFLOW GAS FURNACE

MODELS 373LAV, 376CAV DOWNFLOW/HORIZONTAL and 383KAV, 395CAV UPFLOW GAS FURNACE USER S INORMATION MANUAL USER S INORMATION MANUAL MODELS LAV, CAV DOWNLOW/HORIZONTAL and KAV, CAV UPLOW GAS URNACE NOTE TO INSTALLER: This manual must be left with the equipment user. Upflow WARNING: If

More information

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE 58CLA OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. WELCOME TO A NEW GENERATION

More information

HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace

HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace NOTE TO INSTALLER: This manual must be left with the equipment user. USER: Please read all instructions in the manual and retain all manuals

More information

HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace

HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies

More information

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. c_::_':_-_:_ r'" _" "_1 WARNING: If the information in this manual is not followed exactly, a fire or explosion may Iresult causing property damage, personal injury or [loss of life. m m m Do not store

More information

Owner s Manual. ama PG9MXA TWO --- STAGE CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual. ama PG9MXA TWO --- STAGE CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. Owner s Manual PG9MXA TWO --- STAGE CONDENSING GAS FURNACE NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR

More information

Owner s Manual. Condensing Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual. Condensing Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. Condensing Gas Furnace Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.

More information

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. CONDENSING GAS FURNACE Owner s Manual NOTE: Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may vary based

More information

Owner's Manual. Condensing Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner's Manual. Condensing Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. Condensing Gas Furnace Owner's Manual NOTE: Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may vary based

More information

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. CONDENSING GAS FURNACE Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.

More information

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. CONDENSING GAS FURNACE Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.

More information

Owner s Manual PG9MAB ! WARNING. Condensing Gas Furnace NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual PG9MAB ! WARNING. Condensing Gas Furnace NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. PG9MAB Condensing Gas Furnace Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.

More information

MODEL 340MAV, 350MAV, 352MAV, 355MAV CONDENSING GAS FURNACE

MODEL 340MAV, 350MAV, 352MAV, 355MAV CONDENSING GAS FURNACE USER S INFORMATION MANUAL MODEL 340MAV, 30MAV, 32MAV, 3MAV CONDENSING GAS FURNACE USER: Please read all instructions in the manual and retain all manuals for future reference. NOTE TO INSTALLER: This manual

More information

Owner s Information Manual

Owner s Information Manual 48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)

More information

GAS FURNACE USER S INFORMATION MANUAL FOR OPERATION AND MAINTENANCE OF YOUR GAS-FIRED FURNACE

GAS FURNACE USER S INFORMATION MANUAL FOR OPERATION AND MAINTENANCE OF YOUR GAS-FIRED FURNACE MULTIPOISE, CONDENSING 8MCA, 8MTA, 8MVP, 8MXA GAS FURNACE USER S INFORMATION MANUAL FOR OPERATION AND MAINTENANCE OF YOUR GAS-FIRED FURNACE NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT

More information

USER S INFORMATION MANUAL FOR OPERATION AND MAINTENANCE OF YOUR GAS-FIRED FURNACE

USER S INFORMATION MANUAL FOR OPERATION AND MAINTENANCE OF YOUR GAS-FIRED FURNACE MULTIPOISE, CONDENSING DIRECT VENT/NON-DIRECT VENT 8MCB, 8MTB, 8MVB, 8MXB GAS FURNACE USER S INFORMATION MANUAL FOR OPERATION AND MAINTENANCE OF YOUR GAS-FIRED FURNACE NOTE TO INSTALLER: THIS MANUAL MUST

More information

USER'S MANUAL PGE Single Package Rooftop

USER'S MANUAL PGE Single Package Rooftop USER'S MANUAL PGE Single Package Rooftop Gas Heating/Electric Cooling Units Sizes 036-150 3 to 12-1/2 Tons NOTE TO INSTALLER: This manual should be left with the equipment owner. WARNING: If the information

More information

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit Packaged Gas/Electric Units Owner s Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Disconnect power at fuse box or service panel before performing

More information

Fig. 1 - Unit PGD4, PGS4, WPG4

Fig. 1 - Unit PGD4, PGS4, WPG4 OWNER S MANUAL 14 SEER Single -Package Air Conditioner and Gas Furnace System with R -410A Refrigerant Single Phase 2 to 5 Nominal Tons Three Phase 3 to 5 Nominal Tons PGD4andPGS4SeriesE,WPG4SeriesB Fig.

More information

User's Infomation Manual

User's Infomation Manual User's Infomation Manual 574A GAS HEATING/ELECTRIC COOLING Cancels: OM01-69 OM10-28 02-07 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Note to Installer:

More information

User s Information Manual

User s Information Manual 48AJ,AK,AW,AY020-060 Single-Package Rooftop Gas Heating Units with COMFORTLINK Controls and Scroll Compressors User s Information Manual NOTE TO INSTALLER This manual should be left with the equipment

More information

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable

More information

Bosch 80% AFUE Gas Furnace BGS80 Model

Bosch 80% AFUE Gas Furnace BGS80 Model Bosch 80% AFUE Gas Furnace BGS80 Model 4-Way Multipoise Category I Fan-Assisted Furnace User's Information Manual 3124627 2 Bosch 80% AFUE Gas Furnace User's Information Manual Data subject to change 06.2018

More information

User s Information Manual

User s Information Manual 62DA,DB,DC,DD07-38 Vertical or Horizontal Dedicated 100% Outdoor Air Unit with Optional Gas Heat User s Information Manual NOTE TO INSTALLER This manual should be left with the equipment owner. : If the

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this

More information

User s Information Manual

User s Information Manual 48N2,N3,N4,N5,N6,N7,N8,N9 75-150 Ton Gas Heating/Electric Cooling Units with ComfortLink Controls User s Information Manual NOTE TO INSTALLER: This manual should be left with the equipment owner. : If

More information

Packaged Gas/Electric

Packaged Gas/Electric Packaged Gas/Electric Units Owner's Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Failure to follow this warning can result in Disconnect power

More information

USER'S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW GAS-FIRED FURNACE

USER'S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW GAS-FIRED FURNACE MULTIPOISE, CONDENSING 8MCA, 8MVP, 8MXA HEATING & COOLING USER'S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW GAS-FIRED FURNACE NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW/HORIZONTAL & DOWNFLOW TWO STAGE INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this manual is not

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL CONDENSING GAS FURNACES SAFETY Recognize this symbol as an indication of Important Safety Information If not installed, operated and maintained in

More information

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit Packaged Gas Heat/Electric Cooling Units Owner's Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK. FIRE OR EXPLOSION Failure to follow this warning could result in personal injury,

More information

USER S INFORMATION MANUAL (2,4)SG13B

USER S INFORMATION MANUAL (2,4)SG13B USER S INFORMATION MANUAL (2,4)SG13B Series Gas Heating/Electric Cooling Package Unit Congratulations......your outdoor heating/cooling package unit is a valuable piece of equipment, designed and manufactured

More information

user s information manual

user s information manual user s information manual SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 580F Sizes 036-150 3 to 12 1 / 2 Tons Cancels: New OM11-18 10/15/00 NOTE TO INSTALLER This manual should be left with

More information

User s Information Manual

User s Information Manual 48TJD005-014 48TJE004-014 48TJF004-012 Single-Package Rooftop Heating/Cooling Units User s Information Manual NOTE TO INSTALLER This manual should be left with the equipment owner. FOR YOUR SAFETY Do not

More information

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump Packaged Heat Pumps Owner s Guide to Operating and Maintaining Your Heat Pump NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the spaces

More information

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces P.O. Box 799900, Dallas, TX 75379-9900 USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in manuals,

More information

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL Model RGAC/SGAC Self Contained Cooling/Gas Heat Supersedes: 145.24-O1 (708) Units Form 145.24-O1 (908) MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL CATEGORY III GAS HEATING/ELECTRIC

More information

Central Air Conditioning System

Central Air Conditioning System Owner s Information Manual Central Air Conditioning System NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information,

More information

Owner s Information Manual

Owner s Information Manual 50EZ---A and 50VT ---A Comfort and Performance 13 and 14 SEER Single Packaged Heat Pump System With PuronR (R ---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60) Owner s Information

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL 2005 Lennox Industries Inc. Dallas, Texas, USA USER S INFORMATION MANUAL 13GCSX SERIES UNITS GAS PACKAGED UNITS (2 5 TONS) Armstrong # 38152A068 505,058M 05/09 Supersedes 08/05 Table of Contents Litho

More information

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner. Packaged Air Conditioning Units Owner s Guide to Operating and Maintaining Your Air Conditioner ELECTRICAL SHOCK HAZARD. Failure to follow this warning could result in personal injury, Disconnect power

More information

EL296UHV SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING 2011 Lennox Industries Inc. Dallas, Texas, USA 506769 01 08/2012 Supersedes 10/2011 EL296UHV SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property

More information

Fig. 1 - Unit PHD4 and WPH4

Fig. 1 - Unit PHD4 and WPH4 OWNER S MANUAL 14 SEER Single -Package Heat Pump System with R -410A Refrigerant Single Phase and Three Phase 2 to 5 Nominal Tons PHD4 Series F and WPH4 Series B Fig. 1 - Unit PHD4 and WPH4 A09034 NOTE

More information

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS: U S E R S I N F O R M AT I O N MANUAL 2017 Lennox Industries Inc. Dallas, Texas, USA SL280UHNV SERIES 507650-01 10/2017 Improper installation, adjustment, alteration, service or maintenance can cause property

More information

EL195DFE SERIES GAS FURNACE WARNING

EL195DFE SERIES GAS FURNACE WARNING 2011 Lennox Industries Inc. Dallas, Texas, USA 506739 01 06/2011 EL195DFE SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result in serious injury,

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL 2017 Lennox Industries Inc. Dallas, Texas, USA 506737-01 04/2017 Supersedes 03/2017 USER S INFORMATION MANUAL EL195UHE SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance

More information

WARNING FIRE OR EXPLOSION HAZARD.

WARNING FIRE OR EXPLOSION HAZARD. 2017 Lennox Industries Inc. Dallas, Texas, USA 506897-01 04/2017 Supersedes 10/2015 EL280DF SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL195UHE SERIES GAS FURNACE WARNING WARNING 2012 Lennox Industries Inc. Dallas, Texas, USA 506737-01 12/2012 Supersedes 06/2011 EL195UHE SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property

More information

EL195UH SERIES GAS FURNACE WARNING

EL195UH SERIES GAS FURNACE WARNING 2010 Lennox Industries Inc. Dallas, Texas, USA 506597 01 11/2010 EL195UH SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result in serious injury,

More information

ML180UH SERIES GAS FURNACE WARNING WARNING

ML180UH SERIES GAS FURNACE WARNING WARNING 2017 Lennox Industries Inc. Dallas, Texas, USA 506525-01 04/2017 Supersedes 10/2015 ML180UH SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER USER S INFORMATION MANUAL MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER NOTE TO INSTALLER: This manual must be left with the equipment user. WELCOME TO EFFICIENT HOME COOLING COMFORT Congratulations

More information

WARNING FIRE OR EXPLOSION HAZARD.

WARNING FIRE OR EXPLOSION HAZARD. 2017 Lennox Industries Inc. Dallas, Texas, USA 506698-01 04/2017 Supersedes 10/2015 SL280DFV SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........

More information

NOTE TO EQUIPMENT OWNER:

NOTE TO EQUIPMENT OWNER: Owner s Information Manual Heat Pump System NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the space provided. This information, along

More information

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING 2015 Lennox Industries Inc. Dallas, Texas, USA 506443-01 01/2015 Supersedes 08/2012 SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can

More information

G61MPV SERIES GAS FURNACE WARNING

G61MPV SERIES GAS FURNACE WARNING 2003 Lennox Industries Inc. Dallas, Texas, USA 504,809M 03/2009 Supersedes 06/2003 G61MPV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result

More information

Oil Furnace USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Oil Furnace USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE Oil Furnace USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE MODEL PO8LAA LOW-BOY NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. MODEL PO8UAA

More information

OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES

OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES TABLE OF CONTENTS HOW YOUR GAS FURNACE WORKS...................... 2 KEEP THE FURNACE AREA CLEAR....................... 2 SFOR YOUR SAFETY,

More information

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING 2005 Lennox Industries Inc. Dallas, Texas, USA 505,058M (38152A068) 08/05 Supersedes 06/05 13GCSX Series Units Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE USERS INFORMATION MANUAL MODELS FOR USE WITH NATURAL GAS MHA-50N, MHA-75N, MHA-100N, MHA-125N, MDA-50N, MDA-75N, MDA-100N, MDA-125N FOR USE

More information

OWNER S MANUAL PG9YAA HIGH EFFICIENCY GAS FURNACE ! WARNING SAFETY CONSIDERATIONS

OWNER S MANUAL PG9YAA HIGH EFFICIENCY GAS FURNACE ! WARNING SAFETY CONSIDERATIONS HIGH EFFICIENCY GAS FURNACE OWNER S MANUAL NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: Please read all instructions in the manual and retain all manuals for future reference.

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE...........

More information

USER S INFORMATION MANUAL SLP98UHV SERIES

USER S INFORMATION MANUAL SLP98UHV SERIES 2017 Lennox Industries Inc. Dallas, Texas, USA 506443-01 04/2017 Supersedes 10/2015 USER S INFORMATION MANUAL SLP98UHV SERIES VARIABLE CAPACITY GAS FURNACE Improper installation, adjustment, alteration,

More information

Owner s Manual ! WARNING PLUS 95S - MODEL 355CAV DIRECT VENT 4 -WAY MULTIPOISE MODULATING CONDENSING GAS FURNACE WITH PERFECT SENSET PERFECT HUMIDITYT

Owner s Manual ! WARNING PLUS 95S - MODEL 355CAV DIRECT VENT 4 -WAY MULTIPOISE MODULATING CONDENSING GAS FURNACE WITH PERFECT SENSET PERFECT HUMIDITYT PLU 95 - MODEL 355CAV DIRECT VENT 4 -WAY MULTIPOIE MODULATING CONDENING GA FURNACE WITH PERFECT ENET PERFECT HUMIDITYT Owner s Manual NOTE TO INTALLER: THI MANUAL MUT BE LEFT WITH THE EQUIPMENT UER. UER:

More information

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1*

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1* 352'8&7 /,7(5$785(. /HQQR[,QGXVWULHV,QF 'DOODV 7H[DV 503,877M 02/99 Supersedes 9/98 G24M SERIES 50HZ GAS FURNACE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Litho USA :$51,1* If the information in this

More information

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL FOR YOUR COMBINATION GAS HEATING/ELECTRIC COOLING AIR CONDITIONING UNIT DO NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE BY A SERVICEMAN OR

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL CAST IRON GAS FIRED WATER HEATING BOILERS WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal

More information

Installation Instructions Part No

Installation Instructions Part No Heat Exchanger Cell Kit Cancels: New Installation Instructions Part No. 326600-751 IIK-310A-45-6 6-02 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL SERIES DV GAS FIRED HOT WATER HEATING BOILER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal

More information

User s Information Manual

User s Information Manual User s Information Manual Series 2 Models 1000-2000 MBH Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing

More information

USERS INFORMATION MANUAL

USERS INFORMATION MANUAL MODULAR DX OR CHILLED WATER COOLING WITH ELECTRIC OR HOT WATER HEATING MODELS: US, UM SERIES USERS INFORMATION MANUAL For Installation In: 1. Modular Homes & Buildings 2. Residential Homes LIST OF SECTIONS

More information

user s information manual

user s information manual user s information manual SINGLE PACKAGE ROOFTOP HEAT PUMP UNITS 664A 864A Sizes 024-048 Cancels: New OM02-55 5/1/96 NOTE TO INSTALLER: This manual should be left with the equipment owner. WARNING: Before

More information

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 507350-03 3/2016 Supersedes 9/2015 KG 024, 030, 036, 048, 060, 072, 074, 090 (2, 2-1/2, 3, 4, 5, 6 and 7-1/2 Tons) KG 092, 102, 120, 150 (7-1/2, 8 1/2,

More information

User s Information Manual

User s Information Manual User s Information Manual Series 3 Models 550 and 750 MBH Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL SERIES ODVB GAS FIRED HOT WATER HEATING BOILER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal

More information

CENTRAL AIR CONDITIONER

CENTRAL AIR CONDITIONER USER S INFORMATION MANUAL CENTRAL AIR CONDITIONER NOTE TO INSTALLER: This manual must be left with the equipment user. WELCOME TO EFFICIENT HOME COOLING COMFORT Congratulations on your excellent choice

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL TWO-STAGE SAFETY CONDENSING GAS FURNACES Recognize this symbol as an indication of Important Safety Information IMPORTANT: All manufacturer products

More information

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

OIL FIRED WARM AIR FURNACE. Homeowner Instructions OIL FIRED WARM AIR FURNACE Homeowner Instructions Fire, explosion, asphyxiation and electrical shock hazard. Improper installation and operation could result in death or serious injury. Read this manual

More information

User s Information Manual

User s Information Manual User s Information Manual Gas-Fired Water Boilers With or without Aqua Logic (CWH) Now available Matching High Performance Companion Water Heater (Unit sold separately) If the information in this manual

More information

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 506380 01 11/2009 KGA024, 030, 036, 048, 060, 072 (2, 2 1/2, 3, 4, 5, and 6 Tons) KGA092, 102, 120, 150 (7 1/2, 8-1/2, 10, and 12 Tons) KGA180, 210, 240,

More information

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water Aqua Balance WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water User s Information Manual * Low Lead Content If the information in this manual is not followed exactly, a fire

More information

Combination Cooling/Gas Heat Package Units

Combination Cooling/Gas Heat Package Units User s Manual Combination Cooling/Gas Heat Package Units YSC036E* YHC036E* YSC048E* YHC048E* YSC060E* YHC060E* YSC072E* YHC072E* YSC090E* YHC092E* YSC092E* YHC102E* YSC102E* YHC120E* YSC120E* July 2009

More information

User s Information Manual

User s Information Manual Gas-fired Water boiler Series 2 NOTICE: Series 1/Series 2 identification Read the boiler rating plate to determine the series number. The rating plate is located on the right side of the boiler. User s

More information

User s Information Manual

User s Information Manual User s Information Manual CONDENSING GAS BOILER 220/299/300/399 If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss

More information

HEAT PUMP A GUIDE TO OPERATING AND MAINTAINING YOUR RESIDENTIAL HEAT PUMP UNIT NOTE TO INSTALLER: THIS MANUAL SHOULD BE LEFT WITH THE EQUIPMENT USER.

HEAT PUMP A GUIDE TO OPERATING AND MAINTAINING YOUR RESIDENTIAL HEAT PUMP UNIT NOTE TO INSTALLER: THIS MANUAL SHOULD BE LEFT WITH THE EQUIPMENT USER. HEAT PUMP A GUIDE TO OPERATING AND MAINTAINING YOUR RESIDENTIAL HEAT PUMP UNIT NOTE TO INSTALLER: THIS MANUAL SHOULD BE LEFT WITH THE EQUIPMENT USER. WELCOME TO EFFICIENT YEAR-ROUND COMFORT Congratulations

More information

User s Information Manual

User s Information Manual TM User s Information Manual Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL THESE INSTRUCTIONS APPLY TO THE MODEL GTM SERIES GAS- FIRED WARM AIR FURNACE. This symbol indicates important Safety Related Information FIRE OR EXPLOSION HAZARD Failure to follow

More information

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS) See unit nameplate for manufacturer and address. 506003 01 5/2009 Supersedes 1/2008 TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS) TGA090, 102, 120, 150, TGA120 SHOWN (7

More information

Residential Gas Hybrid Water Heater

Residential Gas Hybrid Water Heater Residential Gas Hybrid Water Heater USER S INFORMATION MANUAL WGRGH20NG75F / WGRGH20NG76F / WGRGH20NG100F WGRGHNG75F / WGRGHNG76F / WGRGHNG100F Models* *A suffix of LP denotes propane gas NOTICE: Westinghouse

More information

User s Information Manual

User s Information Manual User s Information Manual Gas-fired water boilers Series 4 Featuring Flexibility Series 4 If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage,

More information

GOLD. User s Information Manual. Water Boiler Series 4

GOLD. User s Information Manual. Water Boiler Series 4 GV Water Boiler Series 4 User s Information Manual If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. Do

More information

User's Information Manual Customer Property: Contains wiring and service information.

User's Information Manual Customer Property: Contains wiring and service information. User's Information Manual Customer Property: Contains wiring and service information. Please retain RT-SVU03A-EN Library Service Literature Product Section Unitary Product Rooftop Lt. Comm. Model Y_ Literature

More information

AIR CLEANER A GUIDE TO OPERATING AND MAINTAINING YOUR ELECTRONIC. NOTE TO INSTALLER: This manual should be left with the equipment owner.

AIR CLEANER A GUIDE TO OPERATING AND MAINTAINING YOUR ELECTRONIC. NOTE TO INSTALLER: This manual should be left with the equipment owner. Thi d t t d ith F M k 4 0 4 AIR CLEANER A GUIDE TO OPERATING AND MAINTAINING YOUR ELECTRONIC AIR CLEANER NOTE TO INSTALLER: This manual should be left with the equipment owner. A BREATH OF SPRING-FRESH

More information