technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air
|
|
- Julius Perkins
- 5 years ago
- Views:
Transcription
1 technical data FT(Y)S-B Wall Mounted Unit air conditioning systems Split Sky Air
2 Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Specifications are subject to change without prior notice. Zandvoordestraat 300 B Ostend Belgium Internet: EEDE03-/2 03/2003 Prepared in Belgium by Goekint Graphics
3 TABLE OF CONTENTS FT(Y)S-B Features Specifications... 3 Nominal capacity, capacity steps and nominal input Technical specifications 3 Dimensional drawings Piping diagrams Wiring diagrams Sound level... 2 Sound level data Sound pressure spectrum 7 Accessories... 6 Standard accessories Optional accessories 8 Control systems Center of gravity Installation For capacity tables, please refer to part II: outdoor units Split - Sky Air Indoor units
4 Features + Lightweight and compact + Extremely quiet in operation both indoors and outdoors + Automatic air flow director ensures uniform air flow and temperature distribution + Powerful mode can be selected for rapid cooling or heating. + Air purification filter - deodorises the air - helps to prevent bacterial and viral propagation + Photocatalytic deodorising air filter: - powerful decomposes cigarette and pet odours - removes house dust and pollen - deactivates bacteria and viruses + Washable front panel + The outdoor unit can easily be mounted on a roof, a terrace or placed against an outside wall. + The remote control has a 24 hour timer + The indoor model also has a start/stop button mounted on the front panel + Up to 5 indoor units can be operated from a single centralised control + Purpose designed holder provided for your remote control q 7 x Standard Optional 50,60 class only ! FTYS FTS 5 steps 2 Split - Sky Air Indoor units
5 2 Specifications NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FTS20BVMB FTS25BVMB FTS35BVMB FTS50BVMB FTS60BVMB NOMINAL INPUT Cooling Nominal kw For combination indoor + outdoor units (air cooled): INDOOR UNITS FTS20BVMB FTS25BVMB FTS35BVMB FTS50BVMB FTS60BVMB OUTDOOR UNITS RS20BVMB RS25BVMB RS35BVMB RS50BVMB RS60BVMB NOMINAL CAPACITY (2-3) Cooling () Nominal kw NOMINAL INPUT Cooling Nominal kw EER ENERGY LABEL Cooling C C C B C ANNUAL ENERGY CONSUMPTION Cooling kwh ,060 TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FTS20BVMB FTS25BVMB FTS35BVMB FTS50BVMB FTS60BVMB DIMENSIONS Unit H mm W mm ,050 D mm WEIGHT Unit kg COLOUR Unit White SOUND LEVEL Sound pressure (cooling) (4) high db(a) low db(a) Sound power (cooling) (5) high db(a) FAN Air flow rate (cooling) high m 3 /min low m 3 /min Speed steps 5 steps, silent and auto high rpm,260,300,330,330,320 medium rpm,05,055,090,60,60 low rpm ,000 Type Cross flow fan Motor output W 8 40 HEAT EXCHANGER Type ML fin - J7Hi - XA tube Rows x stages x fin pitch mm 2 x 2 x.4 2 x 2 x.4 2 x 6 x.4 2 x 6 x.4 2 x 6 x.4 AIR FILTER Removable/washable/mildew proof TEMPERATURE CONTROL Microprocessor control PIPING CONNECTIONS liquid mm J 6.4 gas mm J 9.5 J 2.7 drain mm J 8.0 INSULATION MATERIAL Heat insulation tape Both liquid and gas pipes For outdoor units Pair application See chapter RS-B Split - Sky Air Indoor units 3
6 2 Specifications 2 ELECTRICAL SPECIFICATIONS For indoor units only: FTS20BVMB FTS25BVMB FTS35BVMB FTS50BVMB FTS60BVMB CURRENT Nominal running current cooling A Maximum running current cooling A See chapter RS-B: electrical data For combination indoor units + outdoor units: FTS20BVMB FTS25BVMB FTS35BVMB FTS50BVMB FTS60BVMB RS20BVMB RS25BVMB RS35BVMB RS50BVMB RS60BVMB CURRENT Nominal running current cooling A Maximum running current cooling A Starting current cooling A See chapter RS-B: electrical data For indoor units only: FTS20BVMB FTS25BVMB FTS35BVMB FTS50BVMB FTS60BVMB POWER SUPPLY VM VM VM VM VM NOMINAL DISTRIBUTION SYSTEM Phase VOLTAGE Frequency Hz Voltage V NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 3 Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. 4 The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this chapter. 5 The sound power level is an absolute value indicating the power which a sound source generates. 6 Energy label: scale from A (most efficient) to G (less efficient). 7 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions) 4 Split - Sky Air Indoor units
7 2 Specifications NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FTYS20BVMB FTYS25BVMB FTYS35BVMB FTYS50BVMB FTYS60BVMB NOMINAL INPUT Cooling Nominal kw Heating Nominal kw For combination indoor + outdoor units (air cooled): INDOOR UNITS FTYS20BVMB FTYS25BVMB FTYS35BVMB FTYS50BVMB FTYS60BVMB OUTDOOR UNITS RYS20BVMB RYS25BVMB RYS35BVMB RYS50BVMB RYS60BVMB NOMINAL CAPACITY (3-4) Cooling () Nominal kw Heating (2) Nominal kw NOMINAL INPUT Cooling Nominal kw Heating Nominal kw EER Cooling Heating ENERGY LABEL Cooling C C C B C Heating C C D B C ANNUAL ENERGY CONSUMPTION Cooling kwh ,060 TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FTYS20BVMB FTYS25BVMB FTYS35BVMB FTYS50BVMB FTYS60BVMB DIMENSIONS Unit H mm W mm ,050 D mm WEIGHT Unit kg COLOUR Unit White SOUND LEVEL Sound pressure high db(a) 38/38 39/39 39/39 44/42 45/44 (cooling/heating) (5) low db(a) 26/26 27/27 27/27 35/* 36/* Sound power (cooling/heating) high db(a) 54/54 55/* 55/* 63/60 63/62 (6) FAN Air flow rate high m 3 /min 7.5/ / /7.9.5/ /7.5 (cooling/heating) low m 3 /min 3.9/ / / /8.8.6/2.8 Speed (cooling/heating) steps 5 steps, silent and auto high rpm,260/,220,300/,260,330/,260,330/,370,320/,330 medium rpm,05/,050,055/,090,090/,00,60/,90,60/,80 low rpm 770/880 80/ / /,000,000/,020 Type Cross flow fan Motor output W HEAT EXCHANGER Type ML fin - J7Hi - XA tube Rows x stages x fin pitch mm 2 x 2 x.4 2 x 2 x.4 2 x 2 x.4 2 x 6 x.4 2 x 6 x.4 AIR FILTER Removable/washable/mildew proof TEMPERATURE CONTROL Microprocessor control PIPING CONNECTIONS liquid mm φ6.4 gas mm φ9.5 φ2.7 drain mm φ8.0 INSULATION MATERIAL Heat insulation tape Both liquid and gas pipes For outdoor units Pair application See chapter RYS-B Split - Sky Air Indoor units 5
8 2 Specifications 2 ELECTRICAL SPECIFICATIONS For indoor units only: FTYS20BVMB FTYS25BVMB FTYS35BVMB FTYS50BVMB FTYS60BVMB CURRENT Nominal running current cooling A heating A Maximum running current cooling A heating A See chapter RXS-B: electrical data For combination indoor units + outdoor units: FTYS20BVMB FTYS25BVMB FTY3S5BVMB FTYS50BVMB FTYS60BVMB RYS20BVMB RYS25BVMB RYS35BVMB RYS50BVMB RYS60BVMB CURRENT Nominal running current cooling A heating A Maximum running current cooling A heating A Starting current cooling A See chapter RYS-B: electrical data heating A For indoor units only: FTYS20BVMB FTYS25BVMB FTYS35BVMB FTYS50BVMB FTYS60BVMB POWER SUPPLY VM VM VM VM VM NOMINAL DISTRIBUTION SYSTEM Phase VOLTAGE Frequency Hz Voltage V NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Nominal heating capacities are based on: indoor temperature 20 CDB * outdoor temperature 7 CDB/6 CWB * refrigerant piping length 7.5m (horizontal) * level difference 0m. 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. 5 The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this chapter. 6 The sound power level is an absolute value indicating the power which a sound source generates. 7 Energy label: scale from A (most efficient) to G (less efficient). 8 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions) 6 Split - Sky Air Indoor units
9 3 Dimensional drawings FT(Y)S B The mark (Y) shows piping direction Rear Air flow (indoor) required space (for performance and maintenance) unit (mm) 3 Left Right (including installation plate) (space for performance) (space for maintenance) (space for maintenance) Home leave lamp Name plate Signal receiver Room temp. thermistor Terminal block with earth terminal Bottom Front grille fixing screws (Inside) Flaps Signal transmitter Intelligent eye sensor Timer lamp Operation lamp Indoor unit ON/OFF switch Gas pipe 9.5Cut (The length of pipe outside the unit: about 300) Drain hose (connecting part I.D. J 4.0, O.D. J 8.0) Liquid pipe J6.4 CuT (the length of pipe outside the unit: about 350) (The hose length on the outside of the unit is approx. 40) Blade angle Up/down (automatic) Cooling, dry Heating Infrared remote control Right/left (manual) Wall hole for embedded piping J 65 hole Wall hole J 65 hole FTYS--: (ARC433A27) FTS--: (ARC433A24) Standard locations of wall holes 3D FT(Y)S50B The mark (Y) shows piping direction Air flow (indoor) required space (for performance and maintenance) unit (mm) Left Rear Rear Right (including installation plate) (space for performance) (space for maintenance) Name plate Required space (space for maintenance) Bottom Flaps Front grille fixing screws (Inside) Signal transmitter Signal receiver Indoor unit ON/OFF switch Intelligent eye sensor Room temp. thermistor Timer lamp Home leave lamp Horizontal blade (Automatic) Cooling, dry Operation lamp Blade angles Heating (FTX -- only) Dry Terminal block with earth terminal (Inside) Gas pipe 2.7Cut (The length of pipe outside the unit: about 340) Liquid pipe J6.4 CuT (the length of pipe outside the unit: about 350) Drain hose (connecting part I.D. J 4.0, O.D. J 8.0) (The hose length on the outside of the unit is approx. 440) Infrared remote control FTYS---: (ARC433A23) FTS---: (ARC433A24) Vertical blade (Automatic) Wall hole for embedded piping J 65 hole Standard locations of wall holes Wall hole J 65 hole 3D Split - Sky Air Indoor units 7
10 3 Dimensional drawings 3 FT(Y)S60B Air flow (indoor) required space (for performance and maintenance) unit (mm) The mark (Y) shows piping direction Rear Left Rear Right (space for maintenance) (space for performance) (including installation plate) Required space (space for maintenance) Bottom Flaps Front grille fixing screws (Inside) Signal transmitter Horizontal blade (Automatic) Cooling Operation lamp Signal receiver Intelligent eye sensor Timer lamp Home leave lamp A FTX(K)S Blade angle Indoor unit ON/OFF switch Room temp. thermistor Heating (FTX -- only) Dry FTX(K)S60-- FTX(K)S7-- Name plate Terminal block with earth terminal B 2.7 Gas pipe J B Cut (The length of pipe outside the unit: about 340) Liquid pipe J A Cut (The length of pipe outside the unit: about 390) Drain hose (connecting part I.D. J 4.0, O.D. J 8.0) (The hose length on the outside of the unit is approx. 440) Vertical blade (Automatic) Infrared remote control Wall hole for embedded piping J 80 hole Wall hole J 80 hole FTYS---: (ARC433A23) FTS---: (ARC433A24) Standard locations of wall holes 3D Split - Sky Air Indoor units
11 4 Piping diagrams FT(Y)S B Indoor unit 4 Heat exchanger Thermistor on heat exchanger Field piping Cross flow fan Fan motor Field piping Refrigerant flow Cooling Heating 4D033698A FT(Y)S50-60B Indoor unit Heat exchanger Thermistor on heat exchanger Field piping Cross flow fan Field piping Fan motor Refrigerant flow Cooling Heating 4D04008 Split - Sky Air Indoor units 9
12 5 Wiring diagrams 5 FT(Y)S B (Terminal for centralised control) Transmission circuit g Field wiring Outdoor CAUTION Signal receiver Note that operation will restart automatically if the main power supply is turned off and then back on again. Infrared remote control Indoor R C70 FU HP H3P MF MS PCB PCB3 RT, R2T S S36 SW XM : Protective earth : Running capacitor : Fuse : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip 3D FT(Y)S50B g Field wiring Rectifier Outdoor Transmission circuit CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again. Infrared remote control Signal receiver Indoor R FG FU H H3 HP H3P MF MS, M2S PCB PCB5 RT, R2T S S38 SW XM : Protective earth : Frame ground : Fuse : Harness : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip 3D038466A 0 Split - Sky Air Indoor units
13 5 Wiring diagrams FT(Y)S60B 5 g Field wiring Rectifier Outdoor Transmission circuit CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again. Infrared remote control Signal receiver Indoor R FG FU H H3 HP H3P MF MS, M2S PCB PCB5 RT, R2T S S38 SW XM : Protective earth : Frame ground : Fuse : Harness : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip 3D038532A Split - Sky Air Indoor units
14 6 Sound level Sound level data Cooling only Sound pressure level Model 230V, 50Hz Sound power level Cooling Measuring location (Cooling) H L FTS25B Location of microphone 54 FTS25B FTS35B FTS50B FTS60B Heat pump Sound pressure level Model 230V, 50Hz Sound power level Cooling/Heating Measuring location (Cooling/Heating) H L FTYS20B 38/38 26/26 Location of microphone 54/54 FTYS25B 39/39 27/27 55/* FTYS35B 39/39 27/27 55/* FTYS50B 44/42 35/* 63/60 FTYS60B 45/44 36/* 63/62 * This information was not available at the time of publication. 2 Split - Sky Air Indoor units
15 6 Sound level 6-2 Sound pressure spectrum Cooling only FTS20B FTS25-35B D D FTS50B FTS60B 4D D NOTE Operation differs with operation and ambient conditions. Legend 50/60Hz / V(H) 50/60Hz / V(L) Split - Sky Air Indoor units 3
16 6 Sound level Sound pressure spectrum Heat pump FTYS20B (Cooling) FTYS20B (Heating) 3D D FTYS25-35B (Cooling) FTYS25-35B (Heating) 3D D03865 NOTE Operation differs with operation and ambient conditions. Legend 50/60Hz / V(H) 50/60Hz / V(L) 4 Split - Sky Air Indoor units
17 6 Sound level 6-2 Sound pressure spectrum FTYS50B (Cooling) FTYS50B (Heating) D D FTYS60B (Cooling) FTYS60B (Heating) 3D D NOTE Operation differs with operation and ambient conditions. Legend 50/60Hz / V(H) 50/60Hz / V(L) Split - Sky Air Indoor units 5
18 7 Accessories Standard accessories FT(Y)S B ja Mounting plate je Remote control holder jk Operation manual jc Air purification filter 2 jg AAA dry-cell batteries 2 jl Installation manual jd Infrared remote control jh Indoor unit fixing screws M4x2L 2 FT(Y)S50-60B ja Mounting plate je Remote control holder jk Operation manual 2 jb Air purification filter with photocatalytic deodorising function 2 jg AAA dry-cell batteries jl Installation manual jd Infrared remote control jh Indoor unit fixing screws M4x2L Optional accessories FT(Y)S-B Option name Wiring adapter for time clock / remote control () Normal open contact KRP43AS Normal open pulse contact KRP43AS Centralised control board up to 5 rooms (2) KRC72 Central remote control DCS302B5 Unified ON/OFF control DCS30B5 Scheduletimer DST30B5 Interface adapter (3) KRP928A2S Air purification filter with frame KAF925B4 Air purification filter without frame KAF925B42 Air purification filter, with deodorising filter KAF952A42 Anti-theft protection for remote control KKF90A4 () Wiring adapter is also required for each indoor unit. (2) Wiring adapter supplied by Daikin. Time clock and other devices: field supply. (3) For DIII-NET adapter 6 Split - Sky Air Indoor units
19 8 Control systems 8- Infrared remote control FT(Y)S B C ON 3 6 HOME LEAVE POWERFUL MODE SILENT TEMP FAN ON/OFF SWING SENSOR ON CANCEL 2 OFF TIMER 3 0 <ARC433A24, A27> Signal transmitter: It sends signals to the indoor unit. 2 Display: It displays the current settings. (In this illustration, each section is shown with all its displays ON for the purpose of explanation.) 3 POWERFUL button: for POWERFUL operation 4 TEMPERATURE adjustment buttons: It changes the temperature setting 5 ON/OFF button: Press this button once to start operation. Press once again to stop it. 6 MODE selector button: It selects the operation mode (Auto, /DryI / Cool u / Heat w / Fan B) 7 FAN setting button: It selects the air flow rate setting. 8 SWING button 9 ON TIMER button 0 OFF TIMER button TIMER setting button: It changes the time setting 2 TIMER CANCEL button: It cancels the timer setting. 3 CLOCK button Split - Sky Air Indoor units 7
20 8 Control systems Infrared remote control FT(Y)S50-60B 2 C ON 3 POWERFUL TEMP ON/OFF 6 MODE FAN SWING ON OFF TIMER CANCEL <ARC433A23, A24> Signal transmitter: It sends signals to the indoor unit. 2 Display: It displays the current settings. (In this illustration, each section is shown with all its displays ON for the purpose of explanation.) 3 POWERFUL button: for POWERFUL operation 4 TEMPERATURE adjustment buttons: It changes the temperature setting 5 ON/OFF button: Press this button once to start operation. Press once again to stop it. 6 MODE selector button: It selects the operation mode (Auto, /DryI / Cool u / Heat w / Fan B) 7 FAN setting button: It selects the air flow rate setting. 8 SWING button Flap (horizontal blade) 9 ON TIMER button 0 OFF TIMER button TIMER setting button: It changes the time setting 2 TIMER CANCEL button: It cancels the timer setting. 3 CLOCK button 8 Split - Sky Air Indoor units
21 9 Center of gravity FT(Y)S B 9 4D020686E FT(Y)S50B 4D04032 FT(Y)S60B 4D04033 Split - Sky Air Indoor units 9
22 0 Installation 0 FT(Y)S B Indoor unit installation drawings ja Mounting plate How to attach the indoor unit. Hook the claws of the bottom frame to the mounting plate. If the claws are difficult to hook, remove the front panel. How to remove the indoor unit. Push up the marked area (at the lower part of the front panel) to release the claws. If it is difficult to release, remove the front panel. Front panel Bottom frame Mounting plate Clip Mark (rear side) M4 x 25L The mounting plate should be installed on a wall which can support the weight of the indoor unit. 30mm or more from ceiling Caulk pipe hole gap with putty. Front grille 50 mm or more from walls (on both side) Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe s cut line. Air filters Appearance of the indoor unit may differ from some models. Service lid This service lid is an open/close type. + Remove the screws on the service lid. + Slide the service lid leftward. + Rotate the service lid upward. jc Air purification filters Install air purification filter on air filter jc Air purification filter Air filter jd Infrared remote controller Before screwing the remote control holder to the wall, make sure that control signals are properly received by indoor unit. je Remote control holder (M3 x 20L) 20 Split - Sky Air Indoor units
23 0 Installation FT(Y)S50-60B Indoor unit installation drawings 0 ja Mounting plate M4 x 25L The mounting plate should be installed on a wall which can support the weight of the indoor unit. The figure shows a 50 class unit. (See Indoor Unit Installation. Installing the mounting plate for details regarding 60 and 7 class units.) Front grille 30mm or more from ceiling Caulk pipe hole gap with putty. Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe s cut line. 50 mm or more from walls (on both side) Wrap the installation pipe with the finishing tape from bottom to top Air filters Only for 60 class units. jb Air purification filter with photocatalytic deodorising function 50 class Tabs (upper 3 locations) Service lid Opening service lid Service lid is opening/closing type. Opening method ) Remove the service lid screws. 2) Lift the service lid upward. Tabs (lower 2 locations) 60 class Tabs (upper 3 locations) Tabs (lower 3 locations) Insert the upper side of the jb Air purification filter with photocatalytic deodorising function into the tabs (upper 3 locations), push the lower side of the filters up a little and into the tabs (lower 2 locations) (lower 3 locations). Split - Sky Air Indoor units 2
technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air
technical data FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order
More informationEEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air
EEDEN08-00 technical data FTXS-G2VB Indoor units air conditioning systems Split - Sky Air EEDEN08-00 technical data FTXS-G2VB Indoor units air conditioning systems Split - Sky Air Indoor Units R-40A FTXS-G2VB
More informationtechnical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air
technical data FTXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect
More informationAir Conditioners. Technical Data FTXS-G
Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Indoor Units R-410A FTXS-G TABLE
More informationtechnical data air conditioning systems FVXS-FV1B R-410A Split Sky Air
technical data FVXS-FV1B R-410A air conditioning systems Split Sky Air Indoor Units R-410A FVXS-FV1B TABLE OF CONTENTS FVXS-FV1B 1 Features.............................................................
More informationtechnical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air
technical data FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDXS-CVMB TABLE OF CONTENTS FDXS-CVMB 1 Features.............................................................
More informationtechnical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air
technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features.............................................................
More informationtechnical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air
technical data FHYKP-B Ceiling Mounted Corner Cassette air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human
More informationtechnical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air
technical data FHYP-B Ceiling Suspended Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and
More informationw w w. d a i k i n. e u ATXS-E
Daikin air conditioners for your home WALL MOUNTED UNIT ATXS-E w w w. d a i k i n. e u Daikin s stylishly elegant wall mounted Siesta unit will grace the dining, living or bedroom of any home. Siesta will
More informationtechnical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air
technical data FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help
More informationDaikin air conditioners for your home
Daikin air conditioners for your home WALL MOUNTE D UNIT w w w. d a i k i n. e u FTKS/FTXS-D Daikin has taken a further step towards achieving the ideal combination of style and efficiency. The D series
More informationDaikin air conditioners for your home
Daikin air conditioners for your home WLL MOUNTED UNIT www.daikineurope.com FTXG-C The UX1 has already won the Good Design ward 2003 for its modern design. This stylish wall mounted unit is available in
More informationFull range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G
Full range A class energy label Air conditioners, heating & cooling for your home WALL MOUNTED UNIT air to air heat pumps www.daikin.eu FTXS-G FOR EVERY HOME, FOR EVERY ROOM unique features Full range
More informationAir Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3
Air Conditioning Technical Data Wall mounted unit EEDEN15-0 FTX-J3 TALE OF CONTENTS FTX-J3 1 Features............................................................. 2 2 Specifications.......................................................
More informationfor your home FLXS-B Flexi type unit air to air heat pumps
Air conditioners, HEATING & COOLING for your home Flexi type unit air to air heat pumps www.daikin.eu FLXS-B TOP CLASS, MADE FOR A LONG FUTURE The importance of well-being and pleasure is increasing in
More informationDaikin air conditioners for your home
Daikin air conditioners for your home WALL MOUNTED UN IT www.daikineurope.com FTKS/FTXS-D Daikin has taken a further step towards achieving the ideal combination of style and efficiency. The D series stylish
More informationAir Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)
Air Conditioning Technical Data Flexi type unit EEDEN14-100 FLXS-B(9) Indoor Unit FLXS-B(9) TABLE OF CONTENTS FLXS-B(9) 1 Features............................................................. 2 2 Specifications.......................................................
More informationfor your home FTYN-GX FT(Y)N-F
Air conditioners for your home W A L L M O U N T E D U N I T www.daikin.eu FTYN-GX FT(Y)N-F FOR EVERY HOME, FOR EVERY ROOM EVERY DAY, MORE AND MORE PEOPLE ARE MAKING A CONSCIOUS EFFORT TO RAISE THEIR QUALITY
More informationBENEFIT FROM LOWER FUEL COSTS.
TODAY, MORE AND MORE PEOPLE ARE MAKING A VERY CONSCIOUS CHOICE TO ENJOY THE COMFORT OF AIR CONDITIONING IN THEIR HOME. IT IS WIDELY RECOGNISED THAT BALANCED AIR CONDITIONING HAS A TANGIBLE EFFECT ON THE
More informationAIR CONDITIONERS, HEATING & COOLING for your home
AIR CONDITIONERS, HEATING & COOLING for your home SLIM CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDXS-E FDXS-C COMFORTABLE AIR, THE WHOLE YEAR THROUGH A comfortable living space provides
More informationfor your home FTXS-G WALL MOUNTED UNIT
Air conditioners for your home WALL MOUNTED UNIT www.daikin.eu FTXS-G BUILT-IN INTELLIGENCE Pair or Multi Depending on the type of climate you want, you can choose between two models: cooling and heating
More informationFTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G
Cooling only INDOOR UNITS FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G Capacity cooling min~nom~max kw 1.3~2.0~2.8 1.3~2.5~3.2 1.4~3.5~4.0 1.7~4.2~5.0 1.7~5.0~5.3 1.7~6.0~6.7 2.3~7.1~8.5 Power
More informationAir conditioners, heating & cooling for the retailmarket and offices
Air conditioners, heating & cooling for the retailmarket and offices floor standing unit air to air heat pumps www.daikin.eu FVQ-B MAXIMUM RELIABILITY, MINIMUM ENERGY USE Advanced climate systems in modern
More informationMULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI
PART 2 - URURU MULTI MULTI SYSTEM The Daikin Ururu Multi heat pump system is unique in its ability to supply comfort heating, cooling humidification and fresh air ventilation. Designed primarily for two
More information1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units
Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply
More informationAir Conditioners Technical Data
Air Conditioners Technical Data W a l l m o u n t e d u n i t E E D E N 2-0 0 CTXS-K Indoor Unit Wall mounted unit CTXS-K TABLE OF CONTENTS CTXS-K Features.............................................................
More informationAir conditioners, heating & cooling for shops,restaurants and offices
Air conditioners, heating & cooling for shops,restaurants and offices 4-way blow ceiling suspended unit air to air heat pumps www.daikin.eu FUQ-B made by daikin : WORLD-FAMOUS FOR EFFICIENCY By purchasing
More informationIncluding mounting plate. General Rating Nameplate. Terminal strip with earth terminal
FTXB20-35C Rear side 770 Right side Standard location of holes in the wall 16 770 549 101 172 6 Left side Front panel fixing screws Including mounting plate 216 198 General Rating Nameplate 41.3 54.5 Hole
More informationAir Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r u n i t - m u l t i m o d e l E E D E N 2-0 0 MXS-K TABLE OF CONTENTS MXS-K Features............................................................. 2 2 Specifications.......................................................
More informationtechnical data air conditioning systems Indoor Units FBQ-C7VEB
technical data Indoor Units FBQ-C7VEB air conditioning systems technical data Indoor Units FBQ-C7VEB air conditioning systems Indoor Units R-40A FBQ-C7VEB TABLE OF CONTENTS FBQ-C7VEB Features.............................................................
More informationON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO
Domestic Air conditioner ON/OFF CAUTION 1. READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. Wall mounted Type Arc-Series HSU-14HR03/R2 2. THIS MANUAL IS USED BY QUALIFIED
More informationAir conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B
Air conditioners, heating & cooling for large spaces CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDQ-B THE MOST ADVANCED CLIMATE CONTROL FOR LARGE SPACES The quality air conditoning of Daikin
More informationAir Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW
Air Conditioning Technical Data Wall mounted unit EEDEN2-00 FTXG-JW Indoor Unit Wall mounted unit FTXG-JW TABLE OF CONTENTS FTXG-JW Features.............................................................
More informationAir Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C
Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-100 FDQ-C TABLE OF CONTENTS FDQ-C 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data EEDEN RXS-F8
Air Conditioning Technical Data EEDEN15-100 RXS-F8 Outdoor Unit RXS-F8 TABLE OF CONTENTS RXS-F8 1 Features............................................................. 2 2 Specifications.......................................................
More informationDesigned. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K
Designed colder climates for AIR TO AIR HEAT PUMPS FTXS-20-25K FTXS35-42-50K Optimised heating solutions down to -25 C outdoor temperatures Prestigious design Prevents winter freezing in summer homes Whisper
More informationtechnical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air
technical data RZQ-B ///Double Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help
More informationAir Conditioners. Technical Data FBQ-C
Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Indoor
More informationAir Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB
Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-204 FXMQ-MB Indoor Unit FXMQ-MB TABLE OF CONTENTS FXMQ-MB 1 Features.............................................................
More informationCeiling Suspended Unit
Ceiling Suspended Unit FHQ-B / RZQ-D(BW1) Wired remote control (standard) Wireless remote control (optional) Ceiling suspended units are the ideal solution for rooms without false ceilings. These indoor
More informationDaikin air conditioners for your home, shops, restaurants and offices
Daikin air conditioners for your home, shops, restaurants and offices CONCEALED CE ILING UN IT www.daikineurope.com FDEQ-B7 Concealed ceiling units are built into the false ceiling, leaving only the suction
More information4-WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices
EPLE03-17 -WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices NEW FCQ-B indoor unit FCQ35/50/60B7 wired reote control (optional) central reote control (optional)
More informationAir Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB
Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFAA2VEB > FFAA2VEB TABLE OF CONTENTS FFA-A 1 Features............................................................. 2 2 Specifications.......................................................
More informationEDUS Heat Pump - D-Series
EDUS 04-740 - Heat Pump - D-Series Split-System Room Air Conditioners D-Series The Single Split Duct-Free System Heat Pump FTXS09DVJU FTXS12DVJU FTXS15DVJU FTXS18DVJU FTXS24DVJU RX09FVJU RX12FVJU RX15FVJU
More informationAir Conditioning. Technical Data. Multi model application EEDEN MXS-E
Air Conditioning Technical Data Multi model application EEDEN1-100 MXS-E TABLE OF CONTENTS MXS-E 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B
Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-100 FDQ-B Indoor Unit FDQ-B TABLE OF CONTENTS FDQ-B 1 Features.............................................................
More informationAir conditioners Heating & Cooling
Air conditioners Heating & Cooling Wall mounted unit SEER and SCOP up to A ++ Discreet, modern design Whisper quiet in operation The right indoor for the right room www.daikin.eu FTXS20-25K/CTXS15-35K
More informationAir Conditioning. Technical Data EEDEN AZQS-BV1
Air Conditioning Technical Data EEDEN14-131 AZQS-BV1 TABLE OF CONTENTS AZQS-BV1 1 Features............................................................. 2 2 Specifications.......................................................
More informationDaikin air conditioners for shops, restaurant and offices
Daikin air conditioners for shops, restaurant and offices ROUNDFLOW CEILING MOUNTED CASSETTE w w w. d a i k i n. e u FCQH-C The new Daikin Sky Air Roundflow Cassette: Daikin has renewed its Sky Air ceiling
More informationtechnical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air
technical data FH(Y)B-FK7 Concealed Ceiling Unit air conditioning systems Split Sky ir Split - Sky ir ISO14001 assures an effective environmental management system in order to help protect human health
More informationAir conditioners Heating & Cooling
Air conditioners Heating & Cooling Wall mounted unit SEER up to A++ Discreet, modern design Whisper quiet in operation The right indoor for the right room Heat pump system www.daikin.eu FTXS-20-25K/CTXS-15-35K
More informationAir Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F
Air Conditioning Technical Data Concealed ceiling unit EEDEN16-100 FDXM-F Indoor Unit FDXM-F TABLE OF CONTENTS FDXM-F 1 Features............................................................. 2 2 Specifications.......................................................
More informationEEDEN technical data EKRTR. Altherma. Altherma
EEDEN08-720 technical data EKRTR Altherma Altherma Altherma Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental
More informationAir Conditioners. Technical Data FTY-H
Air Conditioners Technical Data W a l l M o u n t e d U n i t E E D E N 1 0-1 1 0 FTY-H Air Conditioners Technical Data W a l l M o u n t e d U n i t E E D E N 1 0-1 1 0 FTY-H Indoor Unit Wall mounted
More informationtechnical data air conditioning systems Indoor Units FCQ-C8VEB
technical data Indoor Units FCQ-C8VEB air conditioning systems technical data Indoor Units FCQ-C8VEB air conditioning systems TABLE OF CONTENTS FCQ-C8VEB! 1 Features.............................................................
More informationair conditioners for your home, shops, restaurants, offices, small hotels MULTI MODEL APPLICATIONS
air conditioners for your home, shops, restaurants, offices, small hotels MULTI MODEL APPLICATIONS ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture
More informationfor the retail market, hotels, restaurants and offices
Air conditioners, HEATING & COOLING for the retail market, hotels, restaurants and offices INVERTER DRIVEN CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FBQ-C INtelligent unit, neatly concealed
More informationtechnical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air
technical data RMXS-E7V3B1 Super multi plus air conditioning systems Split Sky Air Outdoor Units R-410A RMXS-E7V3B1 TABLE OF CONTENTS RMXS-E7V3B1 1 Features.............................................................
More informationSiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump
Service Manual Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type
More informationAir Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB
Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA0AUVEB Indoor Unit FAA-A TABLE OF CONTENTS FAA-A 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioners Technical Data
Air Conditioners Technical Data F l o o r s t a n d i n g u n i t E E D E N 2-0 0 FVQ-C Indoor Unit Floor standing unit FVQ-C TABLE OF CONTENTS FVQ-C Features.............................................................
More informationSiUS041638E. Service Manual. Inverter Pair Wall Mounted Type FTX-N Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump
Service Manual Inverter Pair Wall Mounted Type FTX-N Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type FTX-N Series Cooling Only Indoor Unit
More informationRemote control infrared ARC433B76 ARC433A8 ARC433B69
Cooling Only INDOOR UNITS FDKS25E FDKS35E FDKS50C FDKS60C Capacity cooling min~nom~max kw 1.3~2.4~3.0 1.4~3.4~3.8 1.7~5.0~5.3 1.7~6.0~6.5 Power input cooling min~nom~max kw -~0.69~- - ~1.09~- -~1.65~-
More information2. Pictographs 2.1 Basic Operation
Pictographs 2. Pictographs 2.1 Basic Operation ON / OFF button Operation starts and stops every time you press the button. MODE selector button Operation mode changes every time you press the button. H/P
More informationSiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump
Service Manual Inverter Pair Wall Mounted Type J-Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type J-Series Heat Pump Indoor Unit FTX20JV1B FTX25JV1B FTX35JV1B FTX20J2V1B
More informationfor small rooms in multi application
Air conditioners, heating & cooling for small rooms in multi application concealed ceiling unit air to air heat pumps www.daikin.eu FDbq-b HOSPITALITY STARTS WITH A STABLE AND DRAUGHT-FREE INDOOR CLIMATE
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS
More informationair conditioners for your home, shops, restaurants, offices, small hotels w w w. d a i k i n. e u M U L T I M O D E L A P P L I C A T I O N S
air conditioners for your home, shops, restaurants, offices, small hotels M U L T I M O D E L A P P L I C A T I O N S ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in
More informationAir Conditioners Technical Data
Air Conditioners Technical Data W a l l m o u n t e d u n i t E E D E N 2-0 0 4 FTXN-L Indoor Unit Wall mounted unit FTXN-L TABLE OF CONTENTS FTXN-L Features.............................................................
More informationURURU SARARA. Total. comfort solution
URURU SARARA Total comfort solution The new and unique ruru Sarara 5 air treatment techniques in 1 system Lowest environmental impact Perfect comfort Heating a room in winter tends to dry the air, which
More informationAir Conditioners. Technical Data RZQG-L
Air Conditioners Technical Data O u t d o o r u n i t s o p t i m i z e d f o r s e a s o n a l e f f i c i e n c y w w w. d a i k i n. e u RZQG-L Air Conditioners Technical Data O u t d o o r u n i t
More informationService Manual. Inverter Pair. Floor / Ceiling Suspended Dual Type B-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump
Service Manual Inverter Pair Floor / Ceiling Suspended Dual Type B-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair B-Series Cooling Only Indoor Unit Outdoor
More informationSHOPS, RESTA URA NTS, OFFICES, HOTELS,
AIR CONDITIONERS FOR YOUR HOME, A P A RTMENTS, SHOPS, RESTA URA NTS, OFFICES, HOTELS, Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture of high quality air
More informationair conditioners for your home, apartments, shops, restaurants, offices, hotels, w w w. d a i k i n. e u S U P E R M U L T I P L U S
air conditioners for your home, apartments, shops, restaurants, offices, hotels, S U P E R M U L T I P L U S ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in the successful
More informationSiUS04-924_A. Service Manual. Inverter Pair Wall Mounted Type H-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump
Service Manual Inverter Pair Wall Mounted Type H-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type H-Series Cooling Only Indoor Unit FTXS30HVJU
More informationAir Conditioning Technical Data RZASG-MV1
Air Conditioning Technical Data RZASG-MV1 Outdoor Unit RZASG-MV1 TABLE OF CONTENTS RZASG-MV1 1 Features............................................................. 2 2 Specifications.......................................................
More informationEEDEN technical data ERHQ AA. Altherma. Altherma
EEDEN08-720 technical data ERHQ0-06AA Altherma Altherma Altherma Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement
More informationInformation for end users. Floor standing units. 24/7 comfort in a contemporary package
Information for end users Floor standing units 24/7 comfort in a contemporary package Why choose Daikin? Daikin is the world leader when it comes to air conditioning and heating. Thanks to our constant
More informationDaikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort
Daikin Sensira R-32 Refreshingly new Discreet wall mounted unit providing high efficiency and comfort Why choose Daikin 2 Creating the perfect indoor climate is what Daikin units are all about. With more
More informationAir Conditioners Heating & Cooling
Air Conditioners Heating & Cooling 4 - W a y B l o w C e i l i n g M o u n t e d C a s s e t t e Energy label:» Up to class A Heat pump system Inverter technology Fits precisely» in standard modules» of
More informationTABLE OF CONTENTS RMXS-E8V1B
Outdoor Units R-410A RMXS-E8V1B TABLE OF CONTENTS RMXS-E8V1B! 1 Features........................................................... 814 2 Specifications.....................................................
More informationPure comfort & design
Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling
More informationSiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump
Service Manual Inverter Pair Wall Mounted Type G-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type G-Series Cooling Only Indoor Unit FTXS20G2V1B
More informationwhere innovation meets creativity
where innovation meets creativity Stylish wall mounted unit Designed for comfort With more than 90 years of experience in air conditioning and climate control solutions, Daikin combines the best of design
More informationDaikin air conditioners for shops, restaurants and offices
Daikin air conditioners for shops, restaurants and offices WALL MOUNTED UNIT www.daikineurope.co FAQ-B These popular indoor units can be ounted on virtually any type of wall leaving space free for furniture,
More informationPure comfort & design
Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling
More informationAir Conditioning Technical Data RZAG-MV1
Air Conditioning Technical Data RZAG-MV1 TABLE OF CONTENTS RZAG-MV1 1 Features............................................................. 2 2 Specifications.......................................................
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product
More informationAir Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C
Air Conditioning Technical Data Pair, Twin, triple, double twin EEDEN-00 RZQ-C TABLE OF CONTENTS RZQ-C Features............................................................. 2 2 Specifications.......................................................
More informationPure comfort & design
Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling
More informationAir Conditioning. Technical Data EEDEN RZQG-L8/7V1
Air Conditioning Technical Data EEDEN14-100 RZQG-L8/7V1 Outdoor Unit RZQG-L8/7V1 TABLE OF CONTENTS RZQG-L8/7V1 1 Features............................................................. 2 2 Specifications.......................................................
More informationVentilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF
Ventilation Technical Data Outdoor air processing unit, ventilation and air processing EEDEN13-205 FXMQ-MF TABLE OF CONTENTS FXMQ-MF 1 Features.............................................................
More informationAir Purifiers. Technical Data MC70L
Air Purifiers Technical Data E E D E N - 7 0 0 MC70L Air Purifiers Technical Data E E D E N - 7 0 0 MC70L Single Unit MC70L TABLE OF CONTENTS MC70L Features.............................................................
More informationAir Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B
Air Conditioning Technical Data Small concealed ceiling unit EEDEN15-100 FDBQ-B Indoor Unit FDBQ-B TABLE OF CONTENTS FDBQ-B 1 Features............................................................. 2 2
More informationEEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air
EEDEN08-00 technical data RZQS7-40C7VB air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has
More informationPCR0709A. Options. Indoor unit
Indoor unit No. 1 2 3 4 Item 5-room centralised controller Wiring adaptor for time clock/remote controller (Normal open pulse contact/normal open contact) Titanium apatite photocatalytic air-purifying
More informationAir Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C
Air Conditioning Technical Data 4-way blow ceiling mounted cassette EEDEN14-131 ACQ-C Indoor Unit ACQ-C TABLE OF CONTENTS ACQ-C 1 Features.............................................................
More informationtechnical data air conditioning systems RZQ B8W1B Split Sky Air
technical data RZQ00-25-40B8WB air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...
More information