INFORMATION BOOKLET NRG Zone Models 2,3 and 4 Designed, Developed and Manufactured in Ireland

Size: px
Start display at page:

Download "INFORMATION BOOKLET NRG Zone Models 2,3 and 4 Designed, Developed and Manufactured in Ireland"

Transcription

1 INFORMATION BOOKLET NRG Zone Models 2,3 and 4 Designed, Developed and Manufactured in Ireland

2 Section 1 - Introduction THE NRG ZONE CENTRAL HEATING MANIFOLD This document will help you to understand the NRG ZONE and allow you to put it to proper use right away. Please read this document carefully before you decide upon any particular system design and installation procedure you intend to use. For further information on the various methods of installation available to you and the numerous functions of the unit refer to the online help and installation support material on the web - GETTING TO KNOW THE NRG ZONE The NRG ZONE function descriptions and illustrations in this document are for your reference only. They are intended as a guide to help explain how you can take full advantage of the many features that the NRG ZONE system has to offer. In this booklet we have highlighted some of many benefits of the NRG ZONE. The NRG ZONE benefits are universal and apply to all involved in the heating industry, from architects, heating engineers, plumbers, right through to the end user. APPLICATION OF THE PATENTED NRG ZONE TECHNOLOGY Heating systems (such as sealed or open configurations, high temperature appliances; gas or oil boiler and/or geothermal equipment; heat pumps etc.) can all be used to their highest potential with proper, well thought-out installation system layouts. This is where the NRG Zone technology can make the difference. The safety and cost effectiveness of your final system will depend on your specific appliance selection and the pipe work arrangement that you decide on prior to the installation. INSTALLATION AND CUSTOMER SUPPORT You must always be aware of, and consider the health and safety risks associated with lifting and mounting the unit. It is imperative that your installation must comply with all parts of the Building Regulations and all ancillary equipment manufacturer s installation instruction guidelines when installing this product. NRG AWARENESS LTD. cannot accept responsibility for any fault arising through bad workmanship or incorrect application of its products. Our support staff are highly experienced and many hold advanced degrees in a diverse variety of fields in the heating and construction industries. This knowledge and expertise contribute greatly when troubleshooting complex customer projects. We offer quick response times and a global reach, supporting customers all over the world. Our support team is also closely integrated with our development staff in order to actively incorporate customer feedback and requests into our products. NRG ZONE MANIFOLDS ARE ENGINEERED TO OUTPERFORM ALL OTHER FORMS OF HEATING DESIGN SYSTEMS An NRG ZONE manifold is used as a central heating part that allows for rapid system construction, total flexibility, complete reliability and ultimate cost effectiveness in any newbuild or retrofit central heating project. The system s concepts are well proven and comply with good practice and effective design technologies from standard system configurations throughout the heating industry. The NRG ZONE has thousands of potential applications ranging from; commercial property installations to educational institutions, hotels and on to simple domestic applications. The unit is easily calculated to be the most cost effective method known to create superlative heating system performance with the added benefit of decreasing the intended systems complexity and installation time. NRG ZONE products are totally versatile allowing for safe and efficient system construction using oil, gas, solid fuel and renewable energy sources such as heat pumps as well as CHP equipment. NRG ZONE units can be manufactured to any size, providing a completely customisable and dependable solution for any heating project. Design is the most important factor to consider when choosing a reliable system configuration to satisfy environmental concerns as well as economy and comfort for the end-users. In this respect and many others the NRG ZONE is second to none. In a patented logical and dependable way our NRG ZONE manifold performs unlike any other appliance to ensure your system operates to its maximum potential with the minimum of effort. Jim Brennan Chairman NRG AWARENESS LIMITED Any unauthorized modification to the appliance voids the warranty. The standard units are suitable for indoor use only. This unit does not contain asbestos. 2

3 Section 2 - Contents Section 3 Port Connections 3 Section 4 Connection Methods 4 Section 5 Dimensions 4 Section 6 Sealed and Open Vent Systems and Equipment 5 Section 7 Example Gas or Oil Boiler Open System Schematic 6 Section 8 Example Boiler, Heat Pump and Incorporating Solar DHW Schematic 7 Section 9 Example Heat Pump and Solid Fuel Stove Schematic 8 Section 1 0 Example Boiler, Solid Fuel Cook ers and Stoves and Heat Pump System Confi gurations 9 Section 1 1 Example Heat Pump, Boiler and Solid Fuel Stove Schematic 1 0 Section 1 2 Example Bespok e Manifolds and Commercial Applications 1 1 Section 1 3 Bespok e Manifolds 1 1 Section 1 4 System Controls 1 1 Section 1 5 NRG ZONE System Design Sheet 1 2 Section 3 - Port Connections NRG ZONE FLOW ACTIVITY WITH HEAT INPUT AT SIDE CONNECTIONS NRG ZONE FLOW ACTIVITY WITH HEAT INPUT AT BOTTOM CONNECTIONS 3

4 Section 4 - Connection Methods Section 5 - Dimensions FLOW CHAMBER Top Chamber - hottest flow Connection L1 & R1 are Flow ports Connections T1, T2 & T3 have altering functions All connections are 1 female iron fittings BYPASS CHAMBER Centre Chamber bypass/preheat Connections L2 & R2 have altering functions All connections are 1 female iron fittings RETURN CHAMBER Bottom Chamber cold return Connection L3 & R3 are Return ports All connections are 1 female iron fittings ZONES The flow & return connections to the manifold are located at the bottom of the unit (Return Chamber) The Flow connection are labelled A1, B1, C1 and so on All zone connections are 1 male iron fittings ZONE CONFIGURATION The following zone configurations are for standard applications. Alternative layouts for differing applications can be found on our website, The flow connections are labelled A1, B1, C1 and so on Zone pumps are best installed on the flow connections A1, B1, C1 and so on Non-return valves are fitted on each zone return, A2, B2, C2, and so on to prevent any inadvertent heat drift in zones that are not calling for heat For pumped DHW zones; a non-return valve should be fitted to the flow input to the cylinder coil to prevent gravity-fed back feeding of the stored hot water 4

5 Section 6 - Sealed and Open Vent Systems and Equipment SAFETY VENT, EXPANSIONS, COLD FEED AND PRIMARY CIRCUIT DESCRIPTIONS Fig 6.1 Fig 6.2 It is always recommended to over-size a system expansion vessel to avoid later problems. The point of connection of the expansion vessel into the system is important. The pressure-neutral point of an NRG ZONE is perfectly suitable to allow open access to any appliance connected to the expanding system volume as the system contents heat and cool. The physical location of the vessel can be at any convenient unused port in the NRG ZONE giving maximum flexibility, or can be directly on the inlet side of the heating appliance. If a system is extended, an expansion vessel of increased volume (or an additional vessel) may be required, unless previous provision has been made for the extension. The vessel charge pressure (1.5 bar standard) should not be less than the static head pressure at the centre of the expansion vessel. For static heads greater than 15 metres, the vessel charge pressure should be increased. As a guide, the expansion vessel is undersized if the pressure gauge indicates 2.65 bar or above when the boiler is at maximum temperature with all radiators or other zone distribution equipment in circulation. In such a case, a larger (or additional) expansion vessel is required. (Note that an appliance safety valve will commence over-pressure discharge at around 3 bar). It is also important that the discharge outlet from either safety valves or Automatic Air Vents (AAV) should never be located directly above the NRG ZONE unit as inadvertent leakage may go unnoticed and corrode the manifold. W hen installing an open system for a temperature controlled oil or gas boiler it is essential to ensure that the appliance has an unrestricted open vent and separate cold feed. It is also good practice to prevent heat rising in the cold feed pipe. This would warm the expansion tank contents which would evaporate and cause more fresh water to enter the system and damage the ferrous parts. The example at FIG 6.2 shows how a heat-lock loop could be formed to prevent that occurrence. The cold feed and expansion pipe may be connected separately to the manifold if the expansion pipe rises adequately above the tank. Fig 6.2 shows a double T configuration from connections T2 & T3 on the cold feed and expansion which may be useful by serving two functions; Fig 6.3 1) it will create a vent for the cold feed loop & 2) it will also minimise any inadvertent pitching-over of water from the expansion to the tank. W hen installing a solid fuel heating system it is essential to ensure that the appliance has an unrestricted open vent and separate cold feed. Possible solutions are illustrated at Fig 6.3 & Fig 6.4. An expansion header tank is located at the highest point in the system and a cold feed connected through a heat-lock loop as shown. The optional by-pass methods shown in Figs 6.3 & 6.4 connect the expansion pipe through a Flap type non-return valve on a horizontal pipe run and into the return on a the vertical rise from the heat-lock loop. This method is useful when the height of the expansion pipe is restricted. Fig 6.4 The optional expansion pipe to return by-pass strategy shown will minimise the possibility of water rising in the expansion pipe and pitchingover into the tank which is a trait commonly found in poorly configured open systems. Both methods shown provide the pre-requisite safe primary gravity fed heat-leak circuit through the DHW cylinder. However, Option one (Fig 6.3) will make the primary circuit heat available for heating in the NRG ZONE manifold before it heats the Hot Water cylinder. Option two; Fig (6.4) will make the primary circuit heat available for heating hot water in the cylinder before it reaches the NRG ZONE manifold. In both instances the appliance s pump (P1) should be thermostatically controlled by a pipe thermostat fitted on the return to the appliance to turn the pump ON above 55 C. This will prevent condensation forming in the fire-chamber which would otherwise damage the appliance. 5

6 Section 7 - Example Gas or Oil Boiler Open System Schematic SEALED OR OPEN SYSTEM Fig 7 Fig 7 - Represents a possible configuration of a single gas or oil boiler system or a possible dual interconnected system NRG ZONE 3, Boiler (x2), 2 Heating and 1 Hot water Zone. 1. The flow from the boiler is connected to L1 or R1. 2. The boiler return in connected to the L3 or R3. 3. It is not necessary to fit the return to an appliance to the same side of an NRG ZONE as the flow connection. 4. It is of course necessary to cap any unused port connections. 5. It is always necessary to have a venting facility either directly at or in the pipe rising from port T2. 6. The flows to the heating and hot water zones are to be connected as indicated in Section Information on standard Open & Sealed system configurations can be found in Section 6. The example at Fig. 7 shows how a single or two separate thermostatically controlled boilers may be connected to either the left or right hand side of an NRG ZONE manifold to form a fully pumped system. If the boiler(s) to be used are of similar efficiency then L3 and R3 would be used to connect the boiler returns. If one boiler is more efficient than another, say a condensing boiler, then the less efficient boiler s Return would be connected to the manifolds bypass chamber, connections L2 or R2. In this way the condensing boiler would have optimal advantage of collecting the coldest Return water returning from the zones at L3 or R3 and so increase its efficiency. The open configuration of the expansion and cold feed will also provide for constant de-aeration of the pipe-work and manifold as well as an unhindered cold feed to top up the system as required. In this instance non-return valves are used on the heating zone returns to the NRG ZONE manifold to prevent inadvertent heat drift and also on the flow connection to the DHW cylinder to prevent any back-flow from the hot water pipe-work that would otherwise waste the stored DHW temperature. Non return valves should not be fitted on any circuit, such as a DHW primary circuit, when the pipe work in that circuit is used as part of a gravity heat-leak such as required for solid fuel systems. The control wiring should be configured to prevent the boilers firing unless at least one zone control is calling for heat. 6

7 Section 8 - Example Boiler, Heat Pump and Incorporating Solar DHW Schematic SEALED OR OPEN SYSTEM OPTIONS DEPENDANT ON THE PARTICULAR APPLIANCE MANUFACTURER S INSTRUCTIONS Fig 8 Fig 8 - In this example the heat pump & boiler can w ork separately or in tandem along w ith an optional solar DHW system NRG ZONE 3, Boiler, Heat Pump and an optional Solar DHW System 1. The flow from the boiler is connected to L1 and the boiler return in connected to the L2 - bypass circuit. 2. The return to the heat pump (heat exchanger or buffer) is connected to R3. 3. The Flow from the heat pump (heat exchanger or buffer) is connected to both R1 & R2 through motorised valves where; 3.1 Motorised valve MV1 at R1 directs the Heat Pump Flow to the NRG ZONE Flow chamber to be used directly by the zones. 3.2 Motorised valve MV2 at R2 directs the Heat Pump Flow through the NRG ZONE Bypass chamber to preheat the other boiler s return. 4. The flows to the heating and hot water zones are to be connected as indicated in Section 4.5 Page Information on standard Open & Sealed system configurations can be found in Section 6.0 Page 5. The boiler Flow is connected to NRG ZONE Flow chamber and the return connected to the NRG ZONE Bypass chamber. In this circumstance the internal workings of the manifold will not hinder the coldest water returning from the zones to any of the boilers if that boiler alone is called into duty. W hen MV1 is opened, the heat pump flow output is directed to the NRG ZONE Flow chamber to directly supply the heating zones. W hen MV1 closes and MV2 opens the Heat Pump output is directed to the NRG ZONE Bypass chamber from where the boiler collects the then pre-heated water which is then heated to the boiler s higher temperature set point. Therefore in this example, the system can be heated by the boiler alone, the heat pump alone or a combination of the boiler and the heat pump working in tandem. W hen working alone each component has access to the coldest system water and when working together each component has access to the optimum temperature water available in the system to maximise their respective efficiencies. W here a thermal storage buffer is used with the heat-pump a correctly sized pressure/expansion vessel should be fitted to the system to accommodate the expansion of the additional water in the buffer. The optional DHW solar system is connected to the DHW cylinder and has no effect on the function of the NRG ZONE manifold. 7

8 Section 9 - Example Heat Pump and Solid Fuel Stove Schematic OPEN SYSTEM OPTIONS; DEPENDANT ON THE PARTICULAR APPLIANCE MANUFACTURER S INSTRUCTIONS Fig 9 Fig. 9 - Method for integrating a heat pump and another appliance in an open system ; in this example a solid fuel stove NRG ZONE 3, Heat Pump, Solid Fuel Stove & Dual Coil cylinder. 1. The flow from the heat pump is connected to L1 and the heat pump return in connected to L3. 2. The stove flow (rising at all times) is installed with an expansion pipe connected to a horizontal pipe run as a pre-requisite expansion/vent facility. 3. This Primary Flow pipe continues down to where it is connected to the primary coil in the DHW cylinder creating the necessary system heat leak. 4. On leaving the coil the water is directed through an injector tee and back to the stove return connection. This primary circuit must be unobstructed. 5. The secondary flow to the manifold is T connected to the gravity circuit and fed through a non-return valve. 6. The secondary return to the stove is connected to R2 and fed through the stoves pump to the injector tee. 7. The flows to the heating and hot water zones are to be connected as indicated in Section See Information on DHW circuits at Sections 6.3 & 6.4 In this instance a dual coil cylinder is used with one coil connected as a DHW zone and another as a Primary heat-leak. The particulars of the stove connection with an open gravity circuit is outlined in Section 6.3 Page 5 W ith this configuration the system therefore provides for the coldest return water from the zones to be fed to the heat pump to optimise it s co-efficiency of performance (COP) and increase its efficiencies. At the same time the warmest return water is fed to the stove. Stove manufacturer s demand that the return water to their appliances should be controlled by preventing the secondary system pump call until the return has reached at least dew point or 55 C (131 F). W hen the stove primary circuit is above the stove thermostat set point the stove pump should turn On and deliver its heat to the NRG ZONE manifold for zone distribution. If the pipe thermostat detects that the stove has dropped below its setpoint it will turn the pump Off. The primary circuit as shown from the stove will ensure the proper operation of the pre-requisite gravity circuit. Simultaneously the coldest zone water returning to the heat pump will promote its most efficient use. In this instance both appliances may operate simultaneously until the temperature in the heat pump Return has exceeded the appliances minimum temperature and it turns Off. This allows the other hotter appliance to continue as required. If the return circuit cools the heat pump will turn On again. 8

9 Section 10 - Example Boiler, Solid Fuel Cookers and Stoves and Heat Pump System Confi gurations SEALED OR OPEN SYSTEM OPTIONS; DEPENDANT ON THE PARTICULAR APPLIANCE MANUFACTURER S INSTRUCTIONS Fig 10.1 Fig 10.2 Fig 10.1 Show s an example interconnection of an oil or gas cooker w ith a heat pump in a sealed system confi guration w ith a common DHW single coil cylinder NRG ZONE 2, Heat Pump & Oil or Gas Cooker. Both appliances are thermostatically protected & controlled and so can be used in a seal system configuration. The stove has an open path through the manifold, directly to the primary DHW cylinder via the cylinder pump by-pass circuit. The stove will require this heat leak DHW circuit at times when the cooking only function is in operation or to cater for any over-heat situation. The pipe-work shown will create two separate thermo-siphon loops; one from the cooker to the NRG ZONE and the second from the NRG-Zone to the DHW Cylinder. The manifold s open water pathways will not hinder the primary DHW return water re-circulating back to the stove as it operates. 1. The Cooker Flow is connected to L1 & the Return should be fitted to L2. (See Section 3 - NRG ZONE Construction and Connection Methods ). The Primary circuit to the DHW cylinder is connected to the T2 (Flow) & T3 (Return) and circumvents the secondary bypass pump directly to the cylinder coil as indicated. 2. The system being sealed; requires an expansion vessel which may be fitted to the unused L3 port. An Automatic Air Vent is located on the horizontal flow pipe-work to the primary DHW coil. 3. The secondary DHW pump is controlled through an injector tee to the coil based on primary over-heat or time and temperature controlled zone call. 4. The heat pump Flow is connected to R1 and the return to R3 to receive the coldest system water. 5. The flows to the heating are to be connected as indicated in Section 4. Fig 10.2 show s an example interconnection of a solid fuel stove cooker w ith a Solid Fuel Stove in an Open system confi guration w ith a common DHW single coil cylinder NRG ZONE 2, Heat Pump & a Solid Fuel Boiler / Stove. The stove has an open path to the primary flow through the domestic hot water cylinder coil forming the pre-requisite gravity thermosiphoning circuit. By using secondary pumps and injector tee s as indicated, the primary circuit from the stove to the cylinder remains open at all times forming the necessary gravity fed circuit. The secondary circuit pumps can be used as required, assisting the Stove s heat transfer as it s pipe stat reaches temperature. (See Section 9, Fig 9, Overview, Page 8 for more information). The cylinder secondary pump is used to increase the velocity of water through the DHW coil and so speed up the circuit s heat transfer rate if required. 1. The cooker Flow & Return should be attached to the NRG ZONE as described in Section 3 - NRG ZONE Construction and Connection Methods. The Flow to the DHW cylinder Primary circuit is connected to T2 (Flow) -T3 (Return) circuit and circumvents the secondary bypass pump directly to the cylinder coil as indicated. 2. The expansion pipe is tee connected from the horizontal pipe at the highest point of the open circuit 3. The cold feed should be fitted with reference to the cold feed connection methods described in Section 6 Sealed and Open Vent Systems & Equipment. 4. A non-return valve controlled Cold Feed bypass circuit may also be fitted as indicated to prevent inadvertent pitching as explained in Section The flows to the heating are to be connected as indicated in Section 4. 9

10 Section 11 - Example Heat Pump, Boiler and Solid Fuel Stove Schematic OPEN SYSTEM INTERCONNECTION; BOILER, HEAT PUMP, SOLID FUEL STOVE AND A THERMAL STORE (BUFFER) Fig 11 Fig Example method for integrating a heat pump, a Boiler and a solid fuel stove in an open system configuration NRG ZONE 4, Boiler, Heat Pump, Solid Fuel Boiler Stove and thermal Store Buffer. 1. The primary flow from the boiler is fitted to L1. 2. The primary return to the boiler is fitted to L2. 3. The Flow output from the Heat Pump is connected in tandem using motorised valves to act either as a direct heat supply (Through MV1) or to pre-heat the Boiler (Through MV2). 4. The stove is fitted as described in Section 6 - Sealed and Open Vent Systems & Equipment at Fig 6.4 Hot Water priority. 5. The buffer is connected to the NRG ZONE at A1 and A2 but in this instance without a Non-Return valve as the water flow changes direction to either deliver or store system heat as required. 6. The alternate pumps and motorised valve assemblies at the buffer (MV3 & MV4) are facing in the opposite direction to each other to cater for this reverse circulation strategy. 7. The system may be used in an Open configuration as shown or as a sealed system where for instance an oil or gas cooker is used to replace the solid fuel stove. 8. The Buffer can facilitate the storage of geothermal heat from the Heat Pump or to act as an additional safety Thermal Store for the solid fuel appliance to delay the heat transfer to zones until it is required. The gas/oil boiler and heat pump configuration is as described in Section 8 with the difference being that the heat pump flow and preheat connections are directly jointed to the flow and return to the boiler as indicated. In this arrangement the unique method of operation of the NRG ZONE will allow anyone of the three appliances to work independently of the others, in tandem with any other or all three together without compromising the others efficiency. In normal circumstances the buffer is used to store heat from the heat pump during cheaper night rate electric supply times or uniquely to absorb excess heat from the stove as needed. With this method the controls may be configured to store unrequired excessive heat from the stove in the buffer. This heat can be reintroduced to the system if and when it is required. It will of course be necessary to allow for the controls to dump any extraordinary excess heat from the uncontrolled Solid Fuel unit using an appropriately configured controls plan. NRG Awareness Ltd can assist in this area if required. OPERATION OF BUFFER HEATING/DISTRIBUTION CONTROLS: Opening MV1 will allow direct heat from the heat pump to the NRG ZONE and alternatively MV2 will allow the heat Pump to preheat the return to the Oil/Gas Boiler. Operating the MV3/Pump assembly will allow heat to be stored in the buffer and operating the MV4/Pump assembly will allow stored heat to be deliver from the buffer to the system. The buffer therefore becomes highly energy effective to greatly reduce otherwise wasted energy and maintain safety. This unique method will provide for both efficiency and safety as well as maximising the heat distribution potential from the system over a longer period of time. 10

11 Section 12 - Example Bespok e Special Manifolds and Commercial Applications OPEN SYSTEM INTERCONNECTION OF A BOILER, HEAT PUMP, SOLID FUEL STOVE AND A THERMAL STORE (BUFFER) Fig 12 Fig Example Commercial Application including 2 Boilers, 2 heat pump, and 5 Zones w ith a Flow Shunt Pump Facility 1. The left-hand bespoke NRG ZONE shown may be located remotely if required and incorporate a Thermal Store Buffer outlet or a boiler area DHW facility if required. 2. The Heat Pumps and Boilers are connected in parallel to a Header Flow-Return Pipe arrangement with isolation by either non-return valves or motorised control valves as required. 3. The output from the heat pumps are interconnected to both the boilers and the manifold directly as a direct heat supply (through MV1) or as a pre-heat for the boilers (through M V2) as required. (See Section 11). 4. The Flow & Returns from the Boiler connect to L1 and L2 and the Heat Pump is connected to A1 and A2. 2 Bespoke NRG ZONE Manifolds (Special Order) 2 Boilers, 2 Heat Pump, Shunt pump facility. A multi-boiler heating system, otherwise known as a cascade system, is much more economical in running costs than a single large output boiler. W hilst cascades are fairly commonplace in larger gas boiler installations, they would appear to be more the exception than the rule and until the advent of the NRG ZONE method the proper interconnection of different boiler types was certainly a rarity. Yet the logic of using differing boiler types to gain the best system efficiency is indisputable. 5. The Fill/Expansion facility is per; Section 6 - Sealed and Open Vent Systems & Equipment at Fig 6.1 & The Left-hand bespoke NRG ZONE manifold is shown with flange connections at the sides and an optional set of ports (Option A) beneath which can be used as described as a zone or (Option B) as a Thermal Store Buffer facility as described throughout this publication. 7. The Manifold pumps between the NRG ZONE Units have a uniquely energy effective function as the Shunt Pump (P1) can be controlled to maintain the heating temperature in the units and the System Pump (P2) can be controlled to only operate when a remote zone is calling and therefore provide the coldest return water to the boilers as demand calls. Multi-boiler - multi-fuel installations are considerably more energy efficient and will save on fuel bills especially where heat demand patterns vary in different parts of the system. Additionally this configuration is beneficial where there are zoned areas that either do not require the full output capacity of the boiler or are just occasionally used. For premises requiring a larger capacity, the weather is an important factor, imposing variable requirements for maximum output in the coldest winters to minimal in summer. Firing up a large capacity single boiler just to meet a heating top up requirement is not economical. The NRG ZONE example installation shown above identifies just how easy it now is to make super-efficient systems a simple reality. Section 13 - Bespok e Manifolds The NRG Awareness team of engineers are available to assist in the designing of special order manifolds for your particular project requirements. These purpose-built manifolds can be designed to cater for the largest complex system configurations. NRG ZONE manifolds can also be provided to suit any application as a single unit with multiple appliance heat input ports and multiple zone outlets of any size. The units are ideal for off-site pod manufacturing and large or complex heating installations. Bespoke manifolds work in exactly the same way as the standard units described in this manual. Section 14 - System Controls System Controls are our speciality and we can provide either technical advice or support for your projects. We also supply control equipment and panels for a full range of installation from simple domestic to full Building M anagement System solutions. 11

12 Section 15 - NRG ZONE System Design Sheet Drawing Legend T: +353 (0) E: info@nrgawareness.com EMEA Head Office: NRG Awareness, Unit 8, Little Island Industrial Estate, Ballytrasna, Little Island, Co. Cork w w w.nrgaw areness.com

THE OXYVENT TANK. Patent No. EP INSTALLATION MANUAL. This Manual is to be left with owner. TUV Certificate of Design Approval

THE OXYVENT TANK. Patent No. EP INSTALLATION MANUAL. This Manual is to be left with owner. TUV Certificate of Design Approval THE OXYVENT TANK Patent No. EP1264146 INSTALLATION MANUAL This Manual is to be left with owner TUV Certificate of Design Approval Oxyvent Limited, Headford, Killarney, Co. Kerry, Ireland Tel: +353-64-7754449

More information

Link-Up. Solid Fuel Association Guide to Central Heating.

Link-Up. Solid Fuel Association Guide to Central Heating. Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store

More information

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS Today s inescapable need to improve energy efficiency in UK homes has brought installers many opportunities to make extra earnings through the upgrading

More information

Efficiency Maximiser for Solid Fuel Central Heating

Efficiency Maximiser for Solid Fuel Central Heating Efficiency Maximiser for Solid Fuel Central Heating INSTALLATION AND TECHNICAL MANUAL CONTENTS CONTENTS AND CAUTION 1 INTRODUCTION AND INSTRUCTIONS BEFORE LIGHTING BOILER STOVE 2 INSTALLATION INSTRUCTIONS

More information

High Output Boiler Systems

High Output Boiler Systems High Output Boiler Systems Information for Dual System link up methods Instructions for Use, Installation & Servicing For use in GB & IE (Great Britain & Republic of Ireland). IMPORTANT THE OUTER CASING,

More information

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions Xcel HEATBANK Thermal Store The solution to multi-fuel heating Renewable Energy Solutions Description of Standard Options Xcel HEATBANK Thermal Store Size and Capacity 01 02 The Xcel HEATBANK thermal store

More information

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE ISSUE 6 1016 INSTALLATION AND USER GUIDE ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE ADVANCE APPLIANCES LTD PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. IMPORTANT: Gravity circultation

More information

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions HEATBANK Xcel Thermal Store The solution to multi-fuel heating Renewable Energy Solutions A Leading Supplier of Renewable Heat Products and Flue Systems 0333 999 7974 // www.specflue.com Suitable for simultaneous

More information

Sirius FS. Working towards a cleaner future

Sirius FS. Working towards a cleaner future Sirius FS Floor Standing Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 160kW Modular Boiler Applications: up to 640kW Working towards a cleaner future heating specialists 1. Product

More information

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses INSPIRED H I G H H O T EF F ICIENCY E F F I C I E N C Y W A T E R S Y S T E M S E XT REME HIGH EFFICIENCY HO T W AT ER SY ST EMS w i th I N JECT I O N DYN A M I C S T ECHN I CAL DO CUME N TA T I O N I

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION SOLARCYL IM/SC INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented

More information

Kills bills. How Vaillant technologies reduce home heating bills

Kills bills. How Vaillant technologies reduce home heating bills Kills bills How Vaillant technologies reduce home heating bills Energy efficiency is a choice For most people, home heating and hot water systems have always been out of sight and out of mind. But now,

More information

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS cyclone key advantages Cyclone... Responding rapidly to changing market expectations we have evolved the Joule Cyclone vented and unvented stainless

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

SEALED THERMAL STORE

SEALED THERMAL STORE ISSUE 3 0717 INSTALLATION AND USER GUIDE ENERGYMANAGER SEALED THERMAL STORE ADVANCE APPLIANCES LTD PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. SCHEMATIC DIAGRAM OF ENERYMANAGER THERMAL

More information

Combi Konverter Solar System

Combi Konverter Solar System Installation Manual Combi Konverter Solar System Issue 1 These instructions are specific to the integration of the RMSolar Combi Konverter system with the combi boiler. The RMSolar instructions should

More information

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2 Trade of Plumbing Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2 Table of Contents List of Figures... 4 List of Tables... 5 Document Release History... 6 Module 2 Domestic

More information

EFG ENERGY OPTIMISING SYSTEMS

EFG ENERGY OPTIMISING SYSTEMS EFG ENERGY OPTIMISING SYSTEMS High-performance energy control systems for maximum performance from solar collectors and other renewable and non-renewable heat sources Maximum comfort, minimum energy costs

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION 0 RD 0 RI 0000-06 IM/ IM/a INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting

More information

Pivot Stove Hydronic Installation Guide

Pivot Stove Hydronic Installation Guide Pivot Stove Hydronic Installation Guide Install Location When installing the header tank - install directly above the appliance. There needs to be a continual rise between the appliance and the header

More information

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS David Grassl PE Mechanical Engineer Principal Similar to traditional boiler systems, condensing boiler systems have many designs they can operate

More information

PRODUCT DATA SHEETS HEAT PUMPS

PRODUCT DATA SHEETS HEAT PUMPS PRODUCT DATA SHEETS HEAT PUMPS HIGH-TEMPERATURE BRINE-TO-WATER HEAT PUMP: UNIERSAL DESIGN - MAX. FLOW TEMPERATURE 70 C HIGHER FLOW TEMPERATURES FOR HEATING AND DOMESTIC HOT WATER PREPARATION LOW-TEMPERATURE

More information

VENTED CYLINDER RANGE

VENTED CYLINDER RANGE VENTED CYLINDER RANGE FULL RANGE OF VENTED CYLINDERS MANUFACTURED FROM EITHER COPPER OR STAINLESS STEEL ONE NAME. EVERY SOLUTION. WWW.GLEDHILL.NET CONTENTS BUILT ON EXPERIENCE THE GLEDHILL BRAND HAS BEEN

More information

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler H o t Wa te r Syste m s Senator Electric Flow Boilers Making Life Simpler Electric Wet Central Heating The Range Senator electric flow boiler is designed to heat re-circulated water used in wet central

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space. DPS Hi-Flow Mains Pressure Hot Water from an existing vented copper cylinder... Converts an existing hot water cylinder to provide potable mains pressure hot water at high flow rates to all existing outlets.

More information

Understand and apply domestic central heating system installation and maintenance techniques

Understand and apply domestic central heating system installation and maintenance techniques Level: 2 Credit value: 10 URN: Y/602/2888 Unit aim This combination unit provides basic learning in the installation, maintenance, decommissioning and soundness testing of a basic range of wet central

More information

ADVANCE ECB ELECTRIC COMBINATION BOILER

ADVANCE ECB ELECTRIC COMBINATION BOILER ISSUE ISSUE 45 0115 0317 INSTALLATION AND USER GUIDE ADVANCE ECB ELECTRIC COMBINATION BOILER ADVANCE APPLIANCES LTD HOUSEHOLDER - PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE 1 SCHEMATIC

More information

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring Page 1 of 8 IMAGINATION SOLAR LTD Installation Guide B1 Planning the Plumbing and Wiring Unit 4 Montpelier Central, Station Road Bristol BS6 5EE t: 0117 942 6668 f: 0117 942 8998 e: enquiries@imaginationsolar.com

More information

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint Home Heating Guide Why Vaillant? Because they can reduce our heating bills and our carbon footprint Because we re here to help If you have any questions, please call 01634 292300. We can also give you

More information

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER ENERSTORE Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER Newark Copper Cylinder Co Ltd Brunel Drive Newark Notts. NG24 2EG Tel: 01636 678437 Fax: 01636 678964 Internet: www.newarkcoppercylinder.co.uk

More information

Installation and Commissioning Manual

Installation and Commissioning Manual Manual Advance Buffer Vessels for Ground Source Heat Pump Systems Installation and Commissioning Manual Copyright 2015 Kensa Heat Pumps Ltd Page 1 of 12 Contents Page Section Description Page 1... Safety

More information

THERMAL STORE MAINS PRESSURE SYSTEM

THERMAL STORE MAINS PRESSURE SYSTEM THERMAL STORE MAINS PRESSURE SYSTEM Hot Water Storage Solutions Our THERMflow thermal store, works at the heart of your heating and hot water system to provide a high performance, mains pressure solution

More information

Grant Energy Management Control Systems. Includes weather compensation, sequence controllers, low loss headers and zone pumps

Grant Energy Management Control Systems. Includes weather compensation, sequence controllers, low loss headers and zone pumps Grant Energy Management Control Systems Includes weather compensation, sequence controllers, low loss headers and zone pumps Reduces heating bills Environmentally friendly Header systems suitable for systems

More information

SOLAR HEATING SYSTEMS

SOLAR HEATING SYSTEMS introducing SOLAR HEATING SYSTEMS TM the low carbon water heating system June 2008 Irl 1 In this environmentally challenging world, it s time to rethink our heating.....while we still have time. There

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control. Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow

More information

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No. INTRODUCTION The Worcester Greenskies cylinder is a Stainless Steel Unvented Twin Coil Storage vessel specifically designed to be installed in conjunction with the Worcester Greenskies solar package. Should

More information

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5)

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5) March 15, 2011 Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5) Our Daikin Altherma project involves integrating an indoor unit (EKHBX054BA3VJU) with an existing domestic hot

More information

Where gas is not an option,

Where gas is not an option, Where gas is not an option, the perfect solution is the economical Fusion Boiler the most complete electric boiler on the market it s electric Fusion Electric Boiler provides complete peace of mind for

More information

Daikin Blueprint: Delivering Hot Water with a Chiller

Daikin Blueprint: Delivering Hot Water with a Chiller Daikin Blueprint: Delivering Hot Water with a Chiller Analyzing the design of heat recovery on air-cooled chillers and the effect it has on building energy consumption By Paul Crisman Daikin Chiller Applications

More information

Saving energy comes naturally to us.

Saving energy comes naturally to us. Domestic Heat Pumps Saving energy comes naturally to us. Low carbon solutions for heating and hot water The sustainable heating solution for today and tomorrow Home heating with lashings of hot water Whether

More information

experience We carefully design each individual installation to optimise performance Good underfloor heating explained

experience We carefully design each individual installation to optimise performance Good underfloor heating explained 2.7m 23 1.8m Good underfloor heating explained Radiator versus Underfloor Heating 2.7m 1.8m 21 Radiator System Underfloor Heating System Hot air rises. The hotter the air, the quicker it rises. Radiators

More information

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet: PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL Operation and Maintenance THERMAL INTEGRATION LTD. Tel: 0845 2411441 Internet: www.heatweb.com Introduction The District Pandora Heat Bank provides hot

More information

INSTALLATION INSTRUCTIONS Solamander Hydronic Energy Hub Controller SR313

INSTALLATION INSTRUCTIONS Solamander Hydronic Energy Hub Controller SR313 INSTALLATION INSTRUCTIONS Solamander Hydronic Energy Hub Controller SR313 Table of Contents 1 Important Safety Instructions... 3 2 System Description... 4 2.1 The System... 4 2.2 Energy Sources and Uses...

More information

Operation / Installation Manual

Operation / Installation Manual Operation / Installation Manual RINNAI PRESTIGE and RINNAI SUNMASTER Solar Split Systems Electric and Gas Boosted NOT E The appliance must be installed, commissioned and serviced by an authorised person

More information

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy A total hot water and heating thermal store that can also make the most of renewable energy Design, Installation & Servicing Instructions All models comply with the Hot Water Association specification

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary... 5.5.1 General... 13 5.6 CD/30 (Oil Condensing Boiler Installation Assessment Form)... 15 5.6.1 General... 15 5.7 Technician Stationary... 18 5.7.1 CD/40 Energy Efficiency Checklist... 18 5.8 Work Notification

More information

Hydronic Mechanical Panels

Hydronic Mechanical Panels Hydronic Assemblies Inc. 56 Horse Hill Rd Concord NH 2015-2016 Hydronic Mechanical Panels Contact 4805 Main St. Waitsfield, Vermont 05673 Phone : 802-583-5500 WWW.Houseneeds.com Hydronic Assemblies Inc.

More information

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS 3.18.6 Independent Control of Two Space and One Water Heating Circulation Zones in a Fully Pumped System with Three Motorised Valves... 64 3.19 Non Domestic Systems and Processes... 64 SECTION 4 FUEL CONSERVATION

More information

ADVANCE ELECTRIC THERMAL STORE

ADVANCE ELECTRIC THERMAL STORE ISSUE 13 1118 INSTALLATION AND USER GUIDE ADVANCE ELECTRIC THERMAL STORE ADVANCE APPLIANCES LTD HOUSEHOLDER PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. 2 INTRODUCTION Advance thermal

More information

Installation & User Instructions

Installation & User Instructions PROVISIONAL COPY Grant ThermaWave System Thermal Store Range Installation & User Instructions Part No. DOC 78. Rev 01. June 2011 Contents 1 Introduction & General Requirements 3 1.1 Installation Requirements

More information

The Ultimate Solution for Electric Central Heating. Fusion. Comet

The Ultimate Solution for Electric Central Heating. Fusion. Comet The Ultimate Solution for Electric Central Heating Fusion Comet Our range of Electric Boilers provide complete peace of mind for reliability, performance and safety 2 The Fusion range of electric boilers

More information

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark Introduction: Energy use is the single largest operating expense in commercial office

More information

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS G R A N T C Y L I N D E R & S T O R E R A N G E High Efficiency Direct and Indirect Hot Water Storage Solutions FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS GRANT DUOWAVE

More information

THERMflow Thermal Store Cylinders

THERMflow Thermal Store Cylinders THERMflow Thermal Store Cylinders Technical Manual Tel: (01592) 611123 www.mcdonaldwaterstorage.com September 2018 THERMflow Thermal Store Tank Technical Manual Manual must be completed by Installer and

More information

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges 2 The new GT Condenser provides higher efficiencies and low running costs from the Ideal range of pressurised gas boilers. Extracting

More information

2018 Price List & Haus Care Service Guide

2018 Price List & Haus Care Service Guide 2018 Price List & Haus Care Service Guide COMPLETE HEATING TECHNOLOGIES 01636 676325 heathaus.com sales@heathaus.com Installation, Design & Consultation for Domestic & Commercial GAS, OIL & LPG 2 Truly

More information

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS Renewable Range Gledhill - The Cylinder Specialist Thinking of using

More information

Installation & Operation Manual Models: TSU

Installation & Operation Manual Models: TSU TSU-I-O Rev A Installation & Operation Manual Models: TSU 150-940 CAUTION: This appliance is not intended for potable water. This manual must only be used by a qualified heating installer / service technician.

More information

Slide 1 Jul 20, 2006 Viessmann UK

Slide 1 Jul 20, 2006 Viessmann UK Slide 1 Jul 20, 2006 Viessmann UK Why use solar energy Global warming Fossil fuels Fuel price increases Green statement Slide 2 Jul 20, 2006 Viessmann UK Slide 3 Jul 20, 2006 Viessmann UK Choice of Collector

More information

BOILER APPLICATION GUIDE for:

BOILER APPLICATION GUIDE for: T MFC Series Boiler Application Guide GF-148-B TECHNICAL APPLICATION GUIDE BOILER APPLICATION GUIDE for: Piping and Controls, Water Quality, and Single/Multi Installations Applies to MFC Series Models:

More information

Outdoor Reset Control Theory FULL versus PARTIAL reset

Outdoor Reset Control Theory FULL versus PARTIAL reset Outdoor Reset Control Theory FULL versus PARTIAL reset Conventional boilers must be protected against sustained operation at low temperatures. If not, they will be damaged by sustained flue gas condensation.

More information

Commercial Heat Pump Water Heating Solutions

Commercial Heat Pump Water Heating Solutions Commercial Heat Pump Water Heating Solutions - Swimming pool and spa heating - Pool enclosure ventilation + heat recovery - Commercial hot water - Underfloor heating www.waterheating.co.nz reliable If

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

INTA ION MODERN BAR / BATH SHOWER MIXER CP

INTA ION MODERN BAR / BATH SHOWER MIXER CP INTA ION MODERN BAR / BATH SHOWER MIXER 910000CP INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER Page 1 of 10 INTRODUCTION This installation guide has

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09 I N S P I R E D E F F I C I E N C Y Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION Issue 11/09 Technical data Description Extreme 200 Extreme 300 Extreme 500 Weight (empty) kg 63 77

More information

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C SHERPA Th e multifunctional air-water split heat pump. PATENTED TECHNOLOGY The combination of an inverter air-water heat pump together with a water-water heat pump allows heating/ and high temperature

More information

SUN EQUINOX HEATING SYSTEMS

SUN EQUINOX HEATING SYSTEMS SUN EQUINOX HEATING SYSTEMS HIGH-EFFICIENCY HOT WATER SOLUTIONS INSTALLATION & OPERATION MANUAL Production Number: Customer Contact Information Other Resources 260-65-5605 http://www.solarusagenow.com

More information

TORRENT STAINLESS INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION.

TORRENT STAINLESS INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION. TORRENT STAINLESS OPEN VENTED STAINLESS STEEL THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION. WWW.GLEDHILL.NET

More information

THERMAL STORE MAINS PRESSURE SYSTEM

THERMAL STORE MAINS PRESSURE SYSTEM THERMAL STORE MAINS PRESSURE SYSTEM Hot Water Storage Solutions T: 015 1 Our THERMflow thermal store, works at the heart of your heating and hot water system to provide a high performance, mains pressure

More information

Applications and Piping Strategies for Condensing Boilers - Introduction

Applications and Piping Strategies for Condensing Boilers - Introduction Applications and Piping Strategies for Condensing Boilers - Introduction Foil 2, 10/2015 Viessmann Manufacturing Applications and Piping Strategies for Condensing Boilers Webinar Objectives: 1. Control

More information

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy A total hot water and heating thermal store that can also make the most of renewable energy Design, Installation & Servicing Instructions All models comply with the Hot Water Association specification

More information

Breeze extended to include Variable Speed Drives Breeze range extended to include Steam Primary

Breeze extended to include Variable Speed Drives Breeze range extended to include Steam Primary HT-Breeze Instantaneous Water Heaters Breeze extended to include Variable Speed Drives Breeze range extended to include Steam Primary Contents HT-Breeze pages 2-7 When space is tight and hot water needs

More information

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION Ecoline Geo RI HP INSTALLATION MANUAL The Ecoline GEO is an indirect unvented cylinder designed and approved for use with a heat pump. The

More information

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Introduction to Hydronics A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Hydronic heating systems use hot water or steam to deliver the

More information

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler Application Guide Vitodens 100-W B1HA/B1KA Residential Boiler APPLICATION GUIDE The application examples contained in this document serve as a guideline only. These are not engineered drawings and are

More information

INSTALLATION & TECHNICAL MANUAL

INSTALLATION & TECHNICAL MANUAL The FUSION Range of Boilers INSTALLATION & TECHNICAL MANUAL If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: info@electric-heatingcompany.co.uk Or visit our website

More information

Installation Manual. Instrucciones de instalación y manual de usuario 1

Installation Manual. Instrucciones de instalación y manual de usuario 1 Installation Manual Instrucciones de instalación y manual de usuario 1 Installation instructions and user manual V8 2 INDEX 1 GENERAL SAFETY WARNINGS... 4 2 OPERATING PRINCIPLE... 5 3 TECHNICAL FEATURES...

More information

TOTAL SYSTEM EFFICIENCY: CONTROL STRATEGIES & SYSTEM DISTRIBUTION. David Grassl PE Mechanical Engineer Principal

TOTAL SYSTEM EFFICIENCY: CONTROL STRATEGIES & SYSTEM DISTRIBUTION. David Grassl PE Mechanical Engineer Principal TOTAL SYSTE EFFICIENCY: CONTROL STRATEGIES & SYSTE DISTRIBUTION David Grassl PE echanical Engineer Principal This is the second paper in the total system efficiency series that will detail various control

More information

Installation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference.

Installation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference. Installation and Service Instructions for use by heating contractor Solar Control Module for solar connections to the Vitotronic control SM1 SOLAR CONTROL MODULE Product may not be exactly as shown IMPORTANT

More information

Risk Assessment and Control Measures for Household Hot Water Systems

Risk Assessment and Control Measures for Household Hot Water Systems Risk Assessment and Control Measures for Household Hot Water Systems Introduction and Scope The impending changes to the Part G Building regulations have focussed attention on some of the potential hazards

More information

Control Application. Supplement - ACVMax

Control Application. Supplement - ACVMax prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Inta City Concealed Shower Mixing Valve CT80010CP

Inta City Concealed Shower Mixing Valve CT80010CP Inta City Concealed Shower Mixing Valve CT80010CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept

More information

Best Practices for Condensing Boilers

Best Practices for Condensing Boilers ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal at www.cleaverbrooks.com. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For

More information

Enzo Concealed Shower Mixing Valve

Enzo Concealed Shower Mixing Valve Enzo Concealed Shower Mixing Valve EZ40010CP, EZ40013CP & EZ40014CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible.

More information

EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL EnergyMasterHP user guide Cylinder for use with NIBE heat pump systems v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL working with you before, during & after your project Nu-Heat Know-How

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The

More information

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,

More information

SINUS HYDROFIXX THE MANIFOLD WITH INTEGRATED HYDRONIC JUNCTION QUALITY THROUGH EXPERTISE.

SINUS HYDROFIXX THE MANIFOLD WITH INTEGRATED HYDRONIC JUNCTION QUALITY THROUGH EXPERTISE. THE MANIFOLD WITH INTEGRATED HYDRONIC JUNCTION QUALITY THROUGH EXPERTISE. Contents 1. Success of an Innovation.................................................................................. 3 2. Fields

More information

BUILDING MANAGEMENT SYSTEMS. Introduction to Building Management Systems

BUILDING MANAGEMENT SYSTEMS. Introduction to Building Management Systems BUILDING MANAGEMENT SYSTEMS Introduction to Building Management Systems The Building Management System is used for all the functions carried out by the building including energy services security monitoring,

More information

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500 Unvented Calorifier Range. Operating and Maintenance Manual. For Models 125 300 & 500 Telephone 08456 448802 Fax 08456 448803 Emial info@mhgheating.co.uk Web www.mhgheating.co.uk TABLE OF CONTENTS. Section

More information

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd Abstract This paper presents the design approach adopted for the expansion of a large existing

More information

Logamax plus GB142. Applications Manual. Gas condensing boiler

Logamax plus GB142. Applications Manual. Gas condensing boiler Applications Manual Gas condensing boiler WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury, loss of life or property damage. Refer to the installation and

More information

systemate 2000 fully integrated thermal store

systemate 2000 fully integrated thermal store systemate 2000 fully integrated thermal store user instructions In the interest of continuously improving the SysteMate 2000 range. Gledhill Water Storage Ltd reserve the right to modify the product without

More information

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and

More information

A totally renewable heat source

A totally renewable heat source Up-To 44kW, 75kW, 88kW A totally renewable heat source www.central-boiler.co.uk Why choose a Central Boiler? How it works The E-Classic boiler makes heating with wood as simple and efficient as it gets.

More information