DESIGN & TECHNICAL MANUAL

Size: px
Start display at page:

Download "DESIGN & TECHNICAL MANUAL"

Transcription

1 AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA

2 1. INDOOR UNIT : AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA DTR_AS076E_

3 1. INDOOR UNIT CONTENTS 1. FEATURES WIRELESS REMOTE CONTROLLER SPECIFICATIONS DIMENSIONS WIRING DIAGRAMS CAPACITY TABLE COOLING CAPACITY HEATING CAPACITY FAN PERFORMANCE AIR VELOCITY DISTRIBUTION AIR FLOW OPERATION NOISE (SOUND PRESSURE) NOISE LEVEL CURVE SOUND LEVEL CHECK POINT ELECTRICAL CHARACTERISTICS SAFETY DEVICES EXTERNAL INPUT & OUTPUT EXTERNAL INPUT EXTERNAL OUTPUT FUNCTION SETTINGS OPTIONAL PARTS CONTROLLERS OTHERS

4 - (01-01) - 111FEATURES MODELS AS G07LMCA / AO G07LMCA AS G09LMCA / AO G09LMCA AS G12LMCA / AO G12LMCA AS G14LMCA / AO G14LMCA FEATURES zenergy efficiency class AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA MODEL AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA Cooling A++ A++ A++ A++ Heating (Average) A+ A+ A+ A+ zhigh efficient compact design More comfortable airflow zquiet operation INDOOR UNIT Airflow mode can be set in 4 steps and more detailed airflow setting is possible. *21dB only at cooling operation (22dB at heating operation) Fan speed Quiet Noise level 21dB(A) (AS G07/09/12LMCA) zoutdoor unit low noise When air-conditioner operates in large capacity, operation noise of outdoor unit will be suppressed. * In case of room temperature being close to setting temperature, operation noise may not decrease. Rated noise level Noise level down

5 - (01-02) - z10 C HEAT Operation The room temperature can be set to go no lower than 10 C, thus ensuring that the room does not get too cold when not occupied. NOTE: When the room temperature is higher than 10 C, 10 C HEAT operation will not start. Operation starts and maintains the room temperature at 10 C when the temperature drops below 10 C. 20 C 10 C HEAT Button ON Indoor unit operation START 10 C zpowerful operation 20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly. Temperature Powerful Setting temp. Normal mode Time zeconomy operation Example : Cooling operation Economy operation is energy saving, as the set temperature of indoor unit is shifted by 1 C and the maximum electric value of the outdoor unit is suppressed. Temp. Economy operation Shift setting temp Set temperature Normal operation Time Control maximum current zlow outdoor air temperature correspondence Corresponds to cooling operation at -10 C outdoor air temperature Corresponds to heating operation at -15 C outdoor air temperature Cooling Heating -10 to 43 C -15 to 24 C zcorresponds to maximum 20m long piping

6 - (01-03) - 222WIRELESS REMOTE CONTROLLER FEATURES ¾¾4 mode timer setup available (ON / OFF / PROGRAM / SLEEP). ¾¾Easy operation. ¾¾Easy to change custom code (max. 4 custom codes) by button operation. zsimple function setting Setting of the air conditioner selection function is performed by remote controller. zbuilt-in timers Select from four different timer programs (On / Off / Program / Sleep). zprogram timer The program timer operates the on and off timer once within a 24 hour period. zsleep timer The sleep timer function automatically corrects the temperature thermostat setting according to the timer setting to prevent excessive cooling and heating while sleeping. Cooling operation/dry operation When the sleep timer is set, the set temperature automatically rises 1 C every hour. The set temperature can rise up to a maximum of 2 C. Heating operation When the sleep timer is set, the set temperature automatically drops 1 C every 30 minutes. The set temperature can drop to a maximum of 4 C. Timer setting 1 C 2 C 3 C 4 C 60min. 30min. 1 C 2 C 60min. 90min. Timer setting zswitching remote controller custom code After code change Mixed-up A B C D I.U. I.U. I.U. I.U. I.U. I.U. I.U. I.U. A B C D Code selector switch eliminates unit being wrongly switched. (Up to 4 custom codes can be set.) *I.U.=Indoor unit

7 - (01-04) - FUNCTIONS 1 Signal Transmitter C HEAT button 3 MODE button 4 ECONOMY button 5 LOW NOISE button 6 ON TIMER button OFF TIMER button CLOCK ADJUST button 9 POWERFUL button TEMP. Set button ( / ) 11 Start/Stop button FAN button 13 SWING button 14 SET button 15 SLEEP TIMER button 16 CANCEL button 17 RESET button 18 TIMER SELECT button ( / ) 19 Remote Controller Display 20 Operation Mode indicator 21 Low Noise Mode indicator Display panel Temperature Set indicator 23 Fan Speed indicator 24 Swing indicator 25 Clock & Timer indicator NOTE: Some button operations may not be available for all units or systems, refer to the operation manual. To facilitate explanation, the accompanying illustration has been drawn to show all possible indicators; in actual operation, however, the display will only show those indicators appropriate to the current operation. SPECIFICATION SIZE (H x W x D mm) 205 x 61 x 17 WEIGHT ( g ) 122 ACCESSORY Holder

8 - (01-05) - 333SPECIFICATIONS Type WALL MOUNTED INVERTER HEAT PUMP Model name AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA Power source 230V~ 50Hz Available voltage range V~ 50Hz Capacity Cooling Rated kw Btu/h 6,800 8,500 11,600 13,600 Min - Max kw 0.5~ ~4.4 Btu/h 1,700~10,200 1,700-10,900 3,100-13,300 3,100~15,000 Heating Rated kw Btu/h 10,200 10,900 13,600 17,100 Min - Max kw 0.5~ ~6.0 Btu/h 1,700-11,600 1,700-13,600 3,100-18,000 3,100-20,400 Input power Rated Cooling Min - Max kw Rated Heating Min - Max Current Cooling Rated A Heating EER Cooling kw/kw COP Heating Sensible capacity Cooling kw Power factor Cooling % Heating Moisture removal l/h(pints/h) 1.0(1.8) 1.3(2.3) 1.8(3.2) 2.1(3.7) Maximum operating current * Cooling A Heating High Cooling Med Low Fan Sound pressure level Heat exchanger type Enclosure Dimensions (H W D) Weight Connection pipe Operation range Remote controller type Drain hose Airflow rate Heating Quiet m 3 /h High Med Low Quiet Type Q ty Crossflow fan x 1 Motor output W 30 High Cooling Med Low Quiet db(a) High Heating Med Low Quiet Dimensions (H W D) mm Fin pitch Main:320 x 630 x 20 Sub:84 x 630 x 13.3 Main:1.1, Sub:1.4 Rows Stages Main:2 x 20, Sub:1 x 4 Pipe type Copper Fin type Aluminium Material Polystyrene Colour White (Approximate colour of MUNSELL N9.25) Net 268 x 840 x 203 mm Gross 270 x 884 x 336 Net 8.5 kg Gross 10.5 Size Liquid Ø 6.35 (Ø 1/4 in.) mm Gas Ø 9.52 (Ø 3/8 in.) Ø 12.7 (Ø 1/2 in.) Method Flare Cooling C 18 to 32 %RH 80 or less Heating C 16 to 30 Wireless Material PP + LLDPE Size mm Ø 13.8 (I.D.), Ø 15.8 to Ø 16.7 (O.D.) NOTES: Specifications are based on the following conditions Cooling:Indoor temperature of 27 C DB / 19 CWB and outdoor temperature of 35 C DB / 24 CWB. Heating:Indoor temperature of 20 C DB/15 CWB and outdoor temperature of 7 C DB / 6 CWB. Pipe length: 5 m, Height difference: 0 m (Outdoor unit - Indoor unit) The protective function might work when using it in environment out of the temperature range mentioned above. *: The maximum current is the maximum value when operated within the operation range.

9 - (01-06) - Model name ASÜG07LMCA ASÜG09LMCA ASÜG12LMCA ASÜG14LMCA Energy efficiency class Cooling A++ A++ A++ A++ Heating (Average) A+ A+ A+ A+ Pdesign Cooling 2.0 (35 C) 2.5 (35 C) 3.4 (35 C) 4.0 (35 C) kw Heating (Average) 2.3 (-10 C) 2.4 (-10 C) 3.5 (-10 C) 3.9 (-10 C) SEER Cooling kwh/kwh SCOP Heating (Average) Annual energy consumption QCE kwh/a QHE (Average) Sound power level Cooling High db (A) Heating

10 - (01-07) - 444DIMENSIONS MODELS ::AS G07LMCA, AS G09LMCA, AS G12LMCA, AS G14LMCA (Unit : mm)

11 - (01-08) - INSTALLATION PLACE (Unit : mm)

12 - (01-09) - 555WIRING DIAGRAMS MODELS::AS G07LMCA, AS G09LMCA, AS G12LMCA, AS G14LMCA

13 - (01-10) - 666CAPACITY TABLE 66666COOLING CAPACITY MODEL: AS G07LMCA AFR 12.5 Outdoor temperature Indoor temperature CDB CWB CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP MODEL: AS G09LMCA AFR 12.5 Outdoor temperature Indoor temperature CDB CWB CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP MODEL: AS G12LMCA AFR 12.5 Outdoor temperature Indoor temperature CDB CWB CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP MODEL: AS G14LMCA AFR 12.8 Outdoor temperature Indoor temperature CDB CWB CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP AFR : AirFlow Rate (m 3 /min) TC : Total Capacity (kw) SHC : Sensible Heat Capacity (kw) IP : Input Power (kw)

14 - (01-11) HEATING CAPACITY MODEL: AS G07LMCA AFR 12.5 Outdoor temperature Indoor temperature ( CDB) ( CDB) ( CWB) TC IP TC IP TC IP TC IP TC IP MODEL: AS G09LMCA AFR 12.5 Outdoor temperature Indoor temperature ( CDB) ( CDB) ( CWB) TC IP TC IP TC IP TC IP TC IP MODEL: AS G12LMCA AFR 12.5 Outdoor temperature Indoor temperature ( CDB) ( CDB) ( CWB) TC IP TC IP TC IP TC IP TC IP MODEL: AS G14LMCA AFR 12.8 Outdoor temperature Indoor temperature ( CDB) ( CDB) ( CWB) TC IP TC IP TC IP TC IP TC IP AFR : AirFlow Rate (m 3 /min) TC : Total Capacity (kw) IP : Input Power (kw)

15 - (01-12) - 777FAN PERFORMANCE 77777AIR VELOCITY DISTRIBUTION MODELS::AS G07LMCA, AS G09LMCA, AS G12LMCA Conditions: Fan speed: HIGH Operation mode: FAN 2 (m) Unit : m/s TOP VIEW Vertical flap: Up Horizontal flap: Center (m) 3 (m) Unit : m/s TOP VIEW Vertical flap: Up Horizontal flap: Right & Left (m) 3 2 (m) Unit : m/s SIDE VIEW Vertical flap: Up Horizontal flap: Center (m) 3 (m) Unit : m/s SIDE VIEW Vertical flap: Down Horizontal flap: Center (m)

16 - (01-13) - MODEL: AS G14LMCA Conditions: Fan speed: HIGH Operation mode: FAN 2 (m) Unit : m/s TOP VIEW Vertical flap: Up Horizontal flap: Center (m) 3 (m) Unit : m/s TOP VIEW Vertical flap: Up Horizontal flap: Right & Left (m) 3 2 (m) Unit : m/s SIDE VIEW Vertical flap: Up Horizontal flap: Center (m) 3 (m) Unit : m/s SIDE VIEW Vertical flap: Down Horizontal flap: Center (m)

17 - (01-14) AIR FLOW MODELS::AS G07LMCA, AS G09LMCA, AS G12LMCA zcooling Fan speed Number of rotations (r.p.m.) Air flow m 3 /h 750 HIGH 1320 l/s 208 CFM 441 m 3 /h 640 MED 1160 l/s 178 CFM 376 m 3 /h 480 LOW 930 l/s 133 CFM 282 m 3 /h 310 QUIET 680 l/s 86 CFM 182 zheating Fan speed Number of rotations (r.p.m.) Air flow m 3 /h 750 HIGH 1320 l/s 208 CFM 441 m 3 /h 640 MED 1160 l/s 178 CFM 376 m 3 /h 520 LOW 980 l/s 144 CFM 306 m 3 /h 330 QUIET 710 l/s 92 CFM 194

18 - (01-15) - MODEL: AS G14LMCA zcooling Fan speed Number of rotations (r.p.m.) Air flow m 3 /h 770 HIGH 1360 l/s 213 CFM 453 m 3 /h 680 MED 1220 l/s 188 CFM 400 m 3 /h 530 LOW 990 l/s 147 CFM 311 m 3 /h 360 QUIET 750 l/s 100 CFM 212 zheating Fan speed Number of rotations (r.p.m.) Air flow m 3 /h 770 HIGH 1360 l/s 213 CFM 453 m 3 /h 680 MED 1220 l/s 188 CFM 400 m 3 /h 560 LOW 1040 l/s 155 CFM 329 m 3 /h 380 QUIET 770 l/s 105 CFM 223

19 - (01-16) - 888OPERATION NOISE (SOUND PRESSURE) 88888NOISE LEVEL CURVE MODEL: AS G07LMCA zcooling 80 zheating Octave band sound pressure level, db: (0 db= µbar) HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db: (0 db= µbar) HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC NC QUIET NC-15 QUIET ,000 2,000 4,000 8,000 Octave band center frequency,hz ,000 2,000 4,000 8,000 Octave band center frequency,hz MODEL: AS G09LMCA zcooling 80 zheating Octave band sound pressure level, db: (0 db= µbar) HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db: (0 db= µbar) HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC NC QUIET NC-15 QUIET ,000 2,000 4,000 8,000 Octave band center frequency,hz ,000 2,000 4,000 8,000 Octave band center frequency,hz

20 - (01-17) - MODEL: AS G12LMCA zcooling zheating Octave band sound pressure level, db: (0 db= µbar) HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db: (0 db= µbar) HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 NC QUIET 10 QUIET ,000 2,000 4,000 8,000 Octave band center frequency,hz ,000 2,000 4,000 8,000 Octave band center frequency,hz MODEL: AS G14LMCA zcooling 80 zheating Octave band sound pressure level, db: (0 db= µbar) HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db: (0 db= µbar) HIGH NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC QUIET NC QUIET NC ,000 2,000 4,000 8,000 Octave band center frequency,hz ,000 2,000 4,000 8,000 Octave band center frequency,hz

21 - (01-18) SOUND LEVEL CHECK POINT

22 - (01-19) - 999ELECTRICAL CHARACTERISTICS Model name AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA Voltage V 230~ Power supply Frequency Hz 50 Max. operating current A 0.4 Connection cable mm Wiring spec. *1 Limited wiring length m 21 *1: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005.

23 - (01-20) SAFETY DEVICES Model Protection form AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA Circuit protection Current fuse (PC board) 250V 3.15A Fan motor protection Thermal protector program OFF: 105 ± 10 C ON: 90 ± 10 C

24 - (01-21) EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CNA01 Control input - See external CNB01 - Operation status output input/output settings CNB02 - Error status output for details EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop" mode or "Forced stop" mode can be selected with function setting of indoor unit. Unit operation is started at the following contents by adding the contact input of a commercial ON/OFF switch to a connector on the external control PC board and turning it ON. Unit operation Initial setting after power is ON Starting mode other than initial setting Operation mode Auto changeover Mode at previous operation Set temperature 24 C Temperature at previous operation Air flow mode AUTO Mode at previous operation Up-down air direction (swing) Standard air direction (swing OFF) Air direction at previous operation zcircuit diagram example Indoor unit control PC board Communication kit Connected unit Connector Ex.) Switch 1 3 *10 m Signal Optional parts Field supply * Make the distance from the PC board to the connected unit within 10m. Contact capacity: DC 24 V or more, 10 ma or more. Use non-polar relays and switches. zwhen function setting is in "Operation/Stop" mode Input signal Indoor unit ON OFF Operation Stop

25 - (01-22) - zwhen function setting is in "Forced stop" mode Input signal Command ON OFF Forced stop Normal Indoor unit Operation Stop Remote controller ON ON ON Remote control operation invalidity zparts (Optional) Parts name External connect kit Communication kit Model name UTY-XWZXZ5 UTY-XCBXZ2 * For operating the EXTERNAL function, the wall mounted type requires the communication kit in addition to the wire (UTY-XWZXZ5). Wire (External input) : UTY-XWZXZ5

26 - (01-23) EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. zcircuit diagram example Indoor unit control PC board Communication kit Connected unit Connector V DC V *10 m Ex.)Relay unit Ex.)Display Relay power supply Signal Optional parts Field supply *: Make the distance from the PC board to the connected unit within 10 m. Relay spec.: Max. DC 24 V, 10 ma to less than 500 ma. Indoor unit Output signal Operation Stop ON OFF zparts (Optional) Parts name External connect kit Communication kit Model name UTY-XWZXZ5 UTY-XCBXZ2 * For operating the EXTERNAL function, the wall mounted type requires the communication kit in addition to the wire (UTY-XWZXZ5). Wire (External output) : UTY-XWZXZ5

27 - (01-24) - ERROR STATUS OUTPUT An air conditioner error status signal can be output. zcircuit diagram example Indoor unit control PC board Communication kit Connected unit Connector V DC V *10 m Ex.)Relay unit Ex.)Display Relay power supply Signal Error status Optional parts Error Normal Field supply *: Make the distance from the PC board to the connected unit within 10 m. Relay spec.: Max. DC 24 V, 10 ma to less than 500 ma. Output signal zparts (Optional) ON OFF Parts name External connect kit Communication kit Model name UTY-XWZXZ5 UTY-XCBXZ2 * For operating the EXTERNAL function, the wall mounted type requires the communication kit in addition to the wire (UTY-XWZXZ5). Wire (External output) : UTY-XWZXZ5

28 - (01-25) FUNCTION SETTINGS INDOOR UNIT (Setting by remote controller) The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit to malfunction. After the power is turned on, perform the Function Setting according to the installation conditions using the remote controller. The settings may be selected between the following two: Function Number and Setting Value. Settings will not be changed if invalid numbers or setting values are selected. PREPARATION Before turning on the power of the indoor unit: - Confirm whether the piping air-tight test and vacuuming have been conducted. - Reconfirm whether there is no miswiring. Turn on the power of the indoor units. FUNCTION SETTING METHOD (for Wireless remote controller) Entering the Function Setting Mode While pressing the POWERFUL button and SET TEMP. ( ) simultaneously, press the RESET button to enter the function setting mode. STEP 1 Setting the Remote controller Custom code Use the following steps to select the custom code of the remote controller. (Note that the air conditioner cannot receive a custom code if the air conditioner has not been set for the custom code.) The custom codes that are set through this process are applicable only during the Function Setting process. For details on how to set the custom codes through the normal process, refer to "REMOTE CONTROLLER CUSTOM CODE SETTING". 111 Press the SET TEMP. ( ) ( ) button to change the custom code between. Match the code on the display to the air conditioner custom code. (initially set to ) (If the custom code does not need to be selected, press the 10 C HEAT button and proceed to STEP 2.) 222 Press the MODE button and check that the indoor unit can receive signals at the displayed custom code. 333 Press the 10 C HEAT button to accept the custom code, and proceed to STEP 2. The air conditioner custom code is set to "A" prior to shipment. The remote controller resets to custom code A when the batteries in the remote controller are replaced. If you use a custom code other than custom code A, reset the custom code after replacing the batteries. If you do not know the air conditioner custom code setting, try each of the custom codes ( ) until you find the code which operates the air conditioner. STEP 2 Selecting the Function Number and Setting Value 111 Press the SET TEMP. ( ) ( ) buttons to select the function number. (Press the 10 C Heat button to switch between the left and right digits.) 222 Press the POWERFUL button to proceed to setting the value. (Press the POWERFUL button again to return to the function number selection.) 333 Press the SET TEMP. ( ) ( ) buttons to select the setting value. (Press the 10 C Heat button to switch between the left and right digits.) 444 Press the MODE button, then the START/STOP button in order to fix the settings. 555 Press the RESET button to end the function setting mode. 666 After completing the Function Setting, be sure to turn off the power and turn it on again. Function number Setting value CAUTION After turning off the power, wait 30 seconds or more before turning on it again. The Function Setting will not become active unless the power is turned off then on again.

29 - (01-26) - FUNCTION DETAILS 1) Filter sign Functions 2) Room temperature control for cooling 3) Room temperature control for heating 4) Auto restart 5) Room temperature sensor switching 6) Remote controller custom code 7) External input control 8) Room temperature sensor switching (Aux.) 9) Indoor unit fan control for energy saving for cooling 1) Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room. If the indication is not required, select "No indication" (03). (... Factory setting) Setting description Function number Setting value Standard (400 hours) 00 Long interval (1000 hours) Short interval (200 hours) 02 No indication 03 2) Room temperature control for cooling Depending on the installed environment, correction of the room temperature sensor may be required. Select the appropriate control setting according to the installed environment. (... Factory setting) Setting description Function number Setting value Standard 00 Slightly lower control Lower control 02 Higher control 03 3) Room temperature control for heating Depending on the installed environment, correction of the room temperature sensor may be required. Select the appropriate control setting according to the installed environment. (... Factory setting) Setting description Function number Setting value Standard 00 Lower control Slightly higher control 02 Higher control 03

30 - (01-27) - 4) Auto restart Enable or disable automatic restart after a power interruption. (... Factory setting) Setting description Function number Setting value Enable Disable 01 * Auto restart is an emergency function such as for power outage etc. Do not attempt to use this function in normal operation. Be sure to operate the unit by remote controller or external input device. 5) Room temperature sensor switching (Only for wired remote controller) When using the Wired remote controller temperture sensor, change the setting to "Both" (01). (... Factory setting) Setting description Function number Setting value Indoor unit Both 01 * 00: Sensor on the indoor unit is active. *01: Sensors on both indoor unit and wired remote controller is active. *Remote controller sensor must be turned on by using the remote controller. 6) Remote controller custom code (Only for wireless remote controller) The indoor unit custom code can be changed. Select the appropriate custom code. (... Factory setting) Setting description Function number Setting value A 00 B C 02 D 03 7) External input control "Operation/Stop" mode or "Forced stop" mode can be selected. (... Factory setting) Setting description Function number Setting value Operation/Stop mode 00 (Setting prohibited) Forced stop mode 02 8) Room temperature sensor switching (Aux.) To use the sensor on the wired remote controller only, change the setting to "Wired remote controller" (01). This function will only work if the function setting 42 is set at "Both" (01) (... Factory setting) Setting description Function number Setting value Both Wired remote controller 01

31 - (01-28) - 9) Indoor unit fan control for energy saving for cooling Enables or disables the power-saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation. (... Factory setting) Setting description Function number Setting value Disable Enable 01 *00: When the outdoor unit is stopped, the indoor unit fan operates continuously following the setting on the remote controller.. *01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very low speed.

32 - (01-29) - REMOTE CONTROLLER CUSTOM CODE SETTING Use the following steps to select the custom code of the remote controller. (Note that the air conditioner cannot receive a signal if the right custom code has not been set.) 111 Press the START/STOP button until only the clock is displayed on the remote controller display. 222 Press the MODE button for at least five seconds to display the current custom code (initially set to ). 333 Press the SET TEMP. ( ) ( ) button to change the custom code between. Match the code on the display to the air conditioner custom code. 444 Press the MODE button again to return to the clock display. The custom code will be changed. If no buttons are pressed within 30 seconds after the custom code is displayed, the system returns to the original clock display. In this case, start again from step 1. The air conditioner custom code is set to A prior to shipment. The remote controller resets to custom code A when the batteries in the remote controller are replaced. If you use a custom code other than custom code A, reset the custom code after replacing the batteries. If you do not know the air conditioner custom code setting, try each of the custom codes ( ) until you find the code which operates the air conditioner.

33 - (01-30) OPTIONAL PARTS CONTROLLERS Exterior Parts name Model No. Summary Wired remote controller UTY-RVN M Large and full-dot liquid crystal screen, wide and large keys easy to press, user-intuitive arrow key. *Optional communication kit is necessary for installation. Wired remote controller UTY-RNN M The room temperature can be controlled by detecting the temperature accurately with built-in thermo sensor. *Optional communication kit is necessary for installation. Simple remote controller UTY-RSN M Compact remote controller concentrates on the basic functions such as Start/Stop, Fan Control, Temperature Setting and Operation mode. *Optional communication kit is necessary for installation OTHERS Exterior Parts name Model No. Summary Communication kit UTY-XCBXZ2 Use to connect with optional devices and air conditioner PC board. (X1) (X2) External connect kit UTY-XWZXZ5 Required when external device is connected. *Optional communication kit is necessary for installation.

34 2. SINGLE TYPE : AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA DTR_AO130E_

35 CONTENTS SPECIFICATIONS DIMENSIONS REFRIGERANT CIRCUIT WIRING DIAGRAMS CAPACITY COMPENSATION RATE FOR PIPE LENGTH.AND HEIGHT DIFFERENCE ADDITIONAL CHARGE CALCULATION AIR FLOW OPERATION NOISE (SOUND PRESSURE) NOISE LEVEL CURVE SOUND LEVEL CHECK POINT ELECTRICAL CHARACTERISTICS SAFETY DEVICES

36 - (02-01) - 111SPECIFICATIONS Type INVERTER COOLING & HEATING Model name AOÛG07LMCA AOÛG09LMCA AOÛG12LMCA AOÛG14LMCA Power source Available voltage range 230 V~ 50 Hz V Starting current A Fan Sound pressure level Sound power level Heat exchanger type Compressor Refrigerant Air flow rate Cooling 1,670 1,830 1,940 m 3 /h Heating 1,470 1,600 1,700 Type Q'ty Propeller fan 1 Motor output W Cooling db(a) Heating Cooling db(a) Heating Dimensions (H W D) mm Fin pitch Rows x Stages Pipe type Fin type Copper Aluminium Type Q'ty Rotary 1 Motor output W Type (Global Warming Potential) R410A (1975) Charge g Refrigerant oil Type POE(VG74) Enclosure Dimensions ( H W D) Weight Connection pipe Operation range Material Colour Steel BEIGE (Approximate colour of MUNSELL 10YR 7.5/1.0) Net mm Gross Net kg Gross Size Method Pre-charge length Liquid Φ6.35 (Φ 1/4 in.) mm Gas Φ9.52 (Φ 3/8 in.) Φ12.7 (Φ 1/2 in.) Max. length m 20 Max. height difference 15 Flare Cooling -10 to 43 C Heating -15 to NOTES: Specifications are based on the following conditions. Cooling: Indoor temperature of 27 CDB / 19 CWB and outdoor temperature of 35 CDB / 24 CWB. Heating: Indoor temperature of 20 CDB / 15 CWB and outdoor temperature of 7 CDB / 6 CWB. Pipe length: 5 m, Height difference: 0 m. (Outdoor unit - Indoor unit) The protective function might work when using it out the operation range.

37 - (02-02) - 222DIMENSIONS MODELS::AO G07LMCA, AO G09LMCA, AO G12LMCA (Unit : mm) INSTALLATION PLACE 600 mm or more 100 mm or more 250 mm or more (Service space) 200 mm or more 100 mm or more CAUTION When the outdoor temperature is 0 C or less, do not use the accessory drain pipe and drain cap. If the drain pipe and drain cap are used, the drain water in the pipe may freeze in extremely cold weather. (Reverse cycle model only) In areas with heavy snowfall, if the intake and outlet of outdoor unit is blocked with snow, it might become difficult to get warm and it is likely to cause breakdown. Please construct a canopy and a pedestal or place the unit on a high stand (local configured). If the space is larger than stated, the condition will be the same as those without any obstacles.

38 - (02-03) - MODEL: AO G14LMCA (Unit : mm) Top view Front view 540 Airflow 352 Side view Drain pipe mounting place (ø20) Bottom view 4-ø11.3mm hole 209 INSTALLATION PLACE When there are obstacles at the back or front sides. When there are obstacles at the back, side(s), and top. 600 mm or more When there are obstacles at the back, side with the installation of more than one unit. 600 mm or more 100 mm or more 100 mm or more 250 mm or more (Service space) 300 mm or more 250 mm or more 250 mm or more 300 mm or more If the space is larger than stated, the condition will be the same as those without any obstacles.

39 - (02-04) - 333REFRIGERANT CIRCUIT MODELS::AO G07LMCA, AO G09LMCA, AO G12LMCA, AO G14LMCA : Cooling : Heating Refrigerant pipe diameter Liquid: 1/4" (6.35mm) Gas: 3/8" (9.52 mm): AO*G07LMCA, AO*G09LMCA, AO*G12LMCA 1/2" (12.70 mm): AO*G14LMCA

40 - (02-05) - 444WIRING DIAGRAMS MODELS::AO G07LMCA, AO G09LMCA

41 - (02-06) - MODEL: AO G12LMCA

42 - (02-07) - MODEL: AO G14LMCA

43 - (02-08) - CAPACITY COMPENSATION RATE FOR PIPE LENGTH 555 AND HEIGHT DIFFERENCE MODEL: AO G07LMCA, AO G09LMCA COOLING Û1 Indoor unit is higher than outdoor unit. Pipe length (m) Height difference H (m) Û2 Indoor unit is lower than outdoor unit HEATING Pipe length (m) Û1 Indoor unit is higher than outdoor unit Height difference H (m) Û2 Indoor unit is lower than outdoor unit Height difference H Indoor unit Outdoor unit H Outdoor unit H Indoor unit Connection pipe 1 Indoor unit is higher than outdoor unit. Connection pipe 2 Indoor unit is lower than outdoor unit.

44 - (02-09) - MODEL: AO G12LMCA COOLING Û1 Indoor unit is higher than outdoor unit. Pipe length (m) Height difference H (m) Û2 Indoor unit is lower than outdoor unit HEATING Pipe length (m) Û1 Indoor unit is higher than outdoor unit Height difference H (m) Û2 Indoor unit is lower than outdoor unit Height difference H Indoor unit Outdoor unit H Outdoor unit H Indoor unit Connection pipe 1 Indoor unit is higher than outdoor unit. Connection pipe 2 Indoor unit is lower than outdoor unit.

45 - (02-10) - MODEL: AO G14LMCA COOLING Û1 Indoor unit is higher than outdoor unit. Pipe length (m) Height difference H (m) Û2 Indoor unit is lower than outdoor unit HEATING Pipe length (m) Û1 Indoor unit is higher than outdoor unit Height difference H (m) Û2 Indoor unit is lower than outdoor unit Height difference H Indoor unit Outdoor unit H Outdoor unit H Indoor unit Connection pipe 1 Indoor unit is higher than outdoor unit. Connection pipe 2 Indoor unit is lower than outdoor unit.

46 - (02-11) - 666ADDITIONAL CHARGE CALCULATION MODELS::AO G07LMCA, AO G09LMCA Refrigerant type R410A Refrigerant amount g 700 zrefrigerant charge Total pipe length m 15 or less 20 (Max.) Additional charge g g/m MODEL: AO G12LMCA Refrigerant type R410A Refrigerant amount g 850 zrefrigerant charge Total pipe length m 15 or less 20 (Max.) Additional charge g g/m MODEL: AO G14LMCA Refrigerant type R410A Refrigerant amount g 1050 zrefrigerant charge Total pipe length m 15 or less 20 (Max.) Additional charge g g/m

47 - (02-12) - 777AIR FLOW MODELS::AO G07LMCA, AO G09LMCA zcooling Number of rotations (r.p.m.) 730 Air flow m 3 /h 1670 l/s 464 CFM 984 zheating Number of rotations (r.p.m.) Air flow m 3 /h l/s 408 CFM 866 MODEL: AO G12LMCA zcooling Number of rotations (r.p.m.) Air flow m 3 /h l/s 508 CFM 1078 zheating Number of rotations (r.p.m.) Air flow m 3 /h l/s 444 CFM 942

48 - (02-13) - MODEL: AO G14LMCA zcooling Number of rotations (r.p.m.) 850 Air flow m 3 /h 1940 l/s 539 CFM 1141 zheating Number of rotations (r.p.m.) Air flow m 3 /h l/s 472 CFM 1000

49 - (02-14) - 888OPERATION NOISE (SOUND PRESSURE) 88888NOISE LEVEL CURVE MODEL: AO G07LMCA zcooling zheating Octave band sound pressure level, db: (0 db= µbar) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db: (0 db= µbar) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 - NC-25 NC-20 NC-15 NC ,000 2,000 4,000 8,000 Octave band center frequency,hz ,000 2,000 4,000 8,000 Octave band center frequency,hz MODEL: AO G09LMCA zcooling 80 zheating Octave band sound pressure level, db: (0 db= µbar) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db: (0 db= µbar) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 NC ,000 2,000 4,000 8,000 Octave band center frequency,hz ,000 2,000 4,000 8,000 Octave band center frequency,hz

50 - (02-15) - MODEL: AO G12LMCA zcooling zheating Octave band sound pressure level, db: (0 db= µbar) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db: (0 db= µbar) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 NC ,000 2,000 4,000 8,000 Octave band center frequency,hz ,000 2,000 4,000 8,000 Octave band center frequency,hz MODEL: AO G14LMCA zcooling zheating Octave band sound pressure level, db: (0 db= µbar) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db: (0 db= µbar) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 NC ,000 2,000 4,000 8,000 Octave band center frequency,hz ,000 2,000 4,000 8,000 Octave band center frequency,hz

51 - (02-16) SOUND LEVEL CHECK POINT Air flow 1 m

52 - (02-17) - 999ELECTRICAL CHARACTERISTICS Model name AOÛG07LMCA AOÛG09LMCA AOÛG12LMCA AOÛG14LMCA Power supply Voltage V 230 ~ Frequency Hz 50 Max. operating current *1 A Starting current A Wiring spec. *2 Circuit breaker current A 15 Power cable mm *1: The maximum current is the total current of indoor unit and outdoor unit. *2: Wiring spec.: Selected sample (Selected based on Japan Electrotechnical Standards and Codes Committee E0005)

53 - (02-18) SAFETY DEVICES Model Circuit protection Protection form Current fuse (Main printed circuit board) AOÛG07LMCA AOÛG09LMCA AOÛG12LMCA 250V 3.15A 250V 20A AOÛG14LMCA 250V 5A Fan motor protection Terminal protection program OFF: 100 ± 15 C ON: 95 ± 10 C OFF: 150 ± 15 C ON: 120 ± 15 C Compressor protection Terminal protection program (Discharge temp.) OFF:110 C ON: After 7 minutes

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Cassette type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA OUTDOOR AO GLALL AO G4LALL AO G8LALL AO G4LALA . INDOOR UNIT : AU GLVLB AU G4LVLB AU G8LVLB

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G18LFCA AS G24LFCA AS G30LFCA OUTDOOR AO G18LFC AO G24LFL AO G30LFT 1. INDOOR UNIT : AS G18LFCA AS G24LFCA AS G30LFCA DTR_AS052E_01

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFW AOU24RLXFW 1. INDOOR UNIT : ASU18RLF ASU24RLF DTR_AS51E_1 21.12.22 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR G24LMLA OUTDOOR AO G24LALA 1. INDOOR UNIT : DTR_AR063E_01 2013.02.28 - (3) - 1. INDOOR UNIT CONTENTS 1. FEATURES... 01-01 2. WIRED REMOTE CONTROLLER...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL . INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8 . INDOOR UNIT CONTENTS.

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LKC AS A12LKC OUTDOOR AO R09LKC AO R12LKC 1.INDOOR UNIT : AS A09LKC AS A12LKC DTR_AS039E_01 2010.02.24 1. INDOOR UNIT CONTENTS 1.

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_05 2015.06.01 1. INDOOR UNIT

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_01 2013.02.28 1. INDOOR UNIT

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AR C72LHTA AR C90LHTA OUTDOOR AO A72LALT AO A90LALT 1. INDOOR UNIT : AR C72LHTA AR C90LHTA DTR_AR061E_03 2013.11.08 1. INDOOR UNIT CONTENTS

More information

6. DUCT TYPE AR 60FUAK, AR 60UUAK

6. DUCT TYPE AR 60FUAK, AR 60UUAK R410A 6. AR 60FUAK, AR 60UUAK ART60UUAK D2D_AR010E/04 2006.05.30 - (06-01) - 6-1. FEATURE MODELS : AR 60FUAK / AO 60FMAYT AR 60UUAK / AO 60UMAYT ART60UUAK / AOT60UMAYT FEATURES Universal design indoor

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote

More information

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems Market District Commons Black Oak Engineering Daikin Ductless Heat Pump Split Systems N/A N/A M001 Plans Fujitsu ductless heat pump systems 353 Rte. 46 West Fairfield, NJ Fujitsu Fujitsu Halcyon 07004

More information

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8. Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule

More information

Hi-spec Design model. Photo : LT series

Hi-spec Design model. Photo : LT series Hi-spec Design model Photo : LT series 02 Hi-spec Design model * *LT series only 03 Human sensor Human sensor control * Even if people leave the room and forget to turn off the power, 20 minutes after

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

OUTDOOR AIR UNIT DTV_OAE034E_03--CHAPTER

OUTDOOR AIR UNIT DTV_OAE034E_03--CHAPTER DTV_OAE034E_03--CHAPTER01 2015.01.16 CONTENTS 1. FEATURES... A-01 2. SPECIFICATIONS... A-02 3. ELECTRIC CHARACTERISTICS... A-03 4. DIMENSIONS... A-05 5. REFRIGERANT CIRCUIT...A-11 6. WIRING... A-12 6-1.

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL DTW_3SP001E_03 DESIGN & TECHNICAL MANUAL High power series ( 3 phase type ) FUTURE SOLUTION OF DOMESTIC HEATING Air to Water Split type 111OUTDOOR UNIT CONTENTS 3 PHASE TYPE : WO K112LAT, WO K140LAT, WO

More information

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 M-SERIES SINGLE ZONE SYSTEMS MSZ-FH High Performance Wall-Mount Heat Pump Systems 1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 3-1. SPECIFICATIONS... MSZ-FH-6 MSZ-FH09NA

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data EEDEN AZQS-BV1 Air Conditioning Technical Data EEDEN14-131 AZQS-BV1 TABLE OF CONTENTS AZQS-BV1 1 Features............................................................. 2 2 Specifications.......................................................

More information

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1 Revision B: 3. SPECIFICATION has been corrected. Please void OBH732 REVISED EDITION-A. INDOOR UNIT SERVICE MANUAL. OBH732 REVISED EDITION-B Models MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA

More information

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO Domestic Air conditioner ON/OFF CAUTION 1. READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. Wall mounted Type Arc-Series HSU-14HR03/R2 2. THIS MANUAL IS USED BY QUALIFIED

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Internal Condensate

More information

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC TECHNICAL CATALOGUE MONO SPLIT RAK-18PSC RAK-25PSC RAK-35PSC RAC-18WSC RAC-25WSC RAC-35WSC HITACHI Specifications in this catalogue are subject to change without prior notice in order for HITACHI to bring

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

Air Conditioners. Technical Data RZQG-L

Air Conditioners. Technical Data RZQG-L Air Conditioners Technical Data O u t d o o r u n i t s o p t i m i z e d f o r s e a s o n a l e f f i c i e n c y w w w. d a i k i n. e u RZQG-L Air Conditioners Technical Data O u t d o o r u n i t

More information

Highly Efficient,Powerful Heating and Cooling.

Highly Efficient,Powerful Heating and Cooling. AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS* A09LEC AS* A12LEC AO* R09LECN AO* R12LECN R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KE30NKU + CU-KE30NKU CS-KE36NKU + CU-KE36NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KE30NKU CS-KE36NKU Product Code No. 1 852 360 88

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2 Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models

More information

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467. SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B

More information

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100 Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF AOU 9RLFW AOURLFW R40A CONTENTS. DESCRIPTION OF EACH CONTROL OPERATION. COOLING

More information

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Ductless Split Systems Wall-mounted, Single Zone Heat Pump Ductless Split Systems Wall-mounted, Single Zone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N OPERATING MANUAL AIR CONDITIONER DUCT TYPE ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379293-02 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION...

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085

More information

2 &3-4 Head Multi System

2 &3-4 Head Multi System 2 &3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities and

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G09LTCB AS*GLTCB AS*G4LTCB AO*G09LTCN AO*GLTCN AO*G4LTCN R40A CONTENTS. DESCRIPTION OF EACH

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU9RLS ASURLS ASU5RLS AOU9RLSH AOURLSH AOU5RLSH R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

PUHZ-SHW140YHA PUHZ-SHW230YKA

PUHZ-SHW140YHA PUHZ-SHW230YKA 1 Specifications Model Name PUHZ-SHW1YHA PUHZ-SHWYKA Power supply (phase, cycle, voltage) 3φ, 0V, Hz 3φ, 0V, Hz Max. current A 13.0 6.0 Breaker size A 16 3 Outer casing Galvanized plate Galvanized plate

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589) SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service

More information

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type J-Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type J-Series Heat Pump Indoor Unit FTX20JV1B FTX25JV1B FTX35JV1B FTX20J2V1B

More information

SERVICE MANUAL MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No.

SERVICE MANUAL MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No. SPLIT-TYPE AIR CONDITIONERS Revision E: Detail of the indoor fan speed control in COOL or DRY operation has been added (9-1.3, 9-2.3). Please void OBH515 REVISED EDITION-D. INDOOR UNIT SERVICE MANUAL.

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271

More information

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION! CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION... 3 OPERATION... 3 TIMER FUNCTIONS... 5 ON/OFF TIMER... 5 WEEKLY TIMER... 6 TEMPERATURE SET BACK TIMER... 8 FILTER DISPLAY RESET...

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

TECENICAL DATA. Model No. HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I. Wall mounted Type. DC Inverter E-Series

TECENICAL DATA. Model No. HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I. Wall mounted Type. DC Inverter E-Series TECENICAL DATA Order No.AC0902T003V0 Wall mounted Type DC Inverter E-Series Model No. HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I 9K 12K 18K 24K 09K 12K 18K WARNING

More information

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz] PCRHK1543 Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 XS187 & PNRXS187 + CH187 XS187 & PNRXS187 + CL187 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

Ductless Split Systems Concealed Duct Heat Pumps

Ductless Split Systems Concealed Duct Heat Pumps Ductless Split Systems Concealed Duct Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH

More information

SERVICE MANUAL INDOOR UNIT MFZ-KA25VA - MFZ-KA50VA - MFZ-KA35VA - No. OB409. Models. Revision E: SPLIT-TYPE AIR CONDITIONERS REVISED EDITION-E

SERVICE MANUAL INDOOR UNIT MFZ-KA25VA - MFZ-KA50VA - MFZ-KA35VA - No. OB409. Models. Revision E: SPLIT-TYPE AIR CONDITIONERS REVISED EDITION-E SPLIT-TYPE AIR CONDITIONERS Revision E: MFZ-KA5VA- E5, MFZ-KA35VA- E5 and MFZ-KA50VA- E5 have been added. Please void OB409 REVISED EDITION-D. INDOOR UNIT SERVICE MANUAL. OB409 REVISED EDITION-E Models

More information

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) TECHNICAL MANUAL & PARTS LIST DRAFT INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK20ZD-S - 1 - INDOOR UNIT Model SRK20ZD-S OUTDOOR UNIT Model SRC20ZD-S REMOTE

More information

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed. 1 TECHNICAL CHANGES MUZ09UN MUZ-A09NA MUZ12UN MUZ-A12NA MUH15TN MUZ-A15NA MUH17TN MUZ-A17NA MUH24WN MUZ-A24NA MU15TN MUY-A15NA MU17TN MUY-A17NA MU24WN MUY-A24NA 1. Outdoor unit model has been changed.

More information

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1 Order No: MAC0512115C1 CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU Air Conditioner CONTENTS Page Page 1 Safety Precautions 3 2 Specification 5 2.1. CS-E18EKU CU-E18EKU 5 2.2. CS-E21EKU CU-E21EKU 7 3 Location

More information

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type G-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type G-Series Cooling Only Indoor Unit FTXS20G2V1B

More information

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1 SPLIT-TYPE AIR CONDITIONERS Revision D: Changing defrost finish temperature has been corrected (10-1.). Please void OBH516 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G4LFCA AS*G4LFCC AS*G0LFCA AO*G4LFL AO*G4LFCC AO*G0LFT R40A CONTENTS. DESCRIPTION OF EACH

More information

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Mechanical Contractor Company: Contact: Phone: Address:, Distributor Branch

More information

CASSETTE TYPE AIR CONDITIONER

CASSETTE TYPE AIR CONDITIONER CASSETTE TYPE AIR CONDITIONER (5, / 3, BTU/h) TECHNICAL MANUAL Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. CONTENTS. FEATURES....

More information

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT SERVICE MANUAL. OBH589 Models MSZ-EF22VEW - MSZ-EF22VEW - E1 MSZ-EF25VEW - E1 MSZ-EF22VEB - E1 MSZ-EF35VEW - E1 MSZ-EF22VES E1 - MSZ-EF42VEW - E1 MSZ-EF25VEW - E1

More information

TECHNICAL CATALOGUE MONO SPLIT RAK-18PED RAC-18WED RAC-25WED RAC-35WED RAC-X10/14EAG RAC-L10/14EAG RAC-M25/35EAG

TECHNICAL CATALOGUE MONO SPLIT RAK-18PED RAC-18WED RAC-25WED RAC-35WED RAC-X10/14EAG RAC-L10/14EAG RAC-M25/35EAG TECHNICAL CATALOGUE MONO SPLIT RAK-18PED RAK-25PED/25PEDC RAK-35PED/35PEDC RAK-50PED/50PEDC RAS- X10/14/18EAG RAS-L10/14EAG RAS-M25/35/50EAG RAC-18WED RAC-25WED RAC-35WED RAC-X10/14EAG RAC-L10/14EAG RAC-M25/35EAG

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL KHS308 + CH308 KHS368 + CH368 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KHS308 KHS368 Product Code No. 85 354 8 85 354 9 Outdoor

More information

SERVICE MANUAL INDOOR UNIT. No. OBH788

SERVICE MANUAL INDOOR UNIT. No. OBH788 INDOOR UNIT SERVICE MANUAL. Models MSZ-AP25VG - E1, EN1 MSZ-AP35VG - E1, EN1 MSZ-AP42VG - E1, EN1 MSZ-AP50VG - E1, EN1 MSZ-AP25VGK - E1, EN1 MSZ-AP35VGK - E1, EN1 MSZ-AP42VGK - E1, EN1 MSZ-AP50VGK - E1,

More information

SERVICE MANUAL INDOOR UNIT

SERVICE MANUAL INDOOR UNIT SPLIT-TYPE AIR CONDITIONERS Revision A: MSZ-SF25/35/42/50VE- E2 and MSZ-SF25/35/ 42/50VE- EN2 have been added. Please void OBH600. INDOOR UNIT SERVICE MANUAL. OBH600 REVISED EDITION-A Models MSZ-SF25VE

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information