MDX. Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap. Operation & Maintenance Manual

Size: px
Start display at page:

Download "MDX. Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap. Operation & Maintenance Manual"

Transcription

1 MDX Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap Operation & Maintenance Manual MODELS MDX TABLE OF CONTENTS 1.0 GENERAL How to use this manual 1.2 Symbols 1.3 Warranty 1.4 Standard equipment 1.5 Description 1.6 Use 1.7 Saftey instructions 2.0 MACHINE UNPACKING AND HANDLING Unpacking and handling 2.2 Package disposal 3.0 SET UP Machine positioning 3.2 Installation 3.3 Start-up 3.4 Decommissioning 3.5 Control panel 4.0 TIMED CONDENSATE DRAIN TRAP Operation 4.2 Controls 4.3 Maintenance 5.0 MAINTENANCE Each week 5.2 Each month 5.3 Each 6 months 6.0 TROUBLESHOOTING TECHNICAL FEATURES Data sheet 7.2 Electric Wiring diagrams 7.2 Refrigeration diagrams 8.0 INSTALLATION LAYOUT 18 1/19 Cod Rev

2 1.0 GENERAL 1.1 How to use this manual All features of this machine, all information on safety, machine installation, operation, adjusting and maintenance are described in this manual. This manual is integral part of this machine and should absolutely be read and understood by any person operating and maintaining this machine. Should this machine be sold again, this manual should be given to the new machine owner. Should this manual be lost, please ask for a new copy to your authorized dealer. 1.2 Symbols Symbols included in the below frames refer to safety instructions to be followed during the machine operation and maintenance. The other symbols refer to machine features and are either on the machine or on explanation screens. Air inlet Condensate drainage Air outlet Direction of rotation of ventilator motor Electric shock danger! 1.3 Warranty This product is supplied after being regularly tested. It is guaranteed for 12 months from the delivery date. This warranty applies provided the customer has complied with contract and administrative rules and the machine is installed and used under the instructions of this manual. The manufacturer agrees in fixing or replacing all parts proved to be worn and faulty at the factory free of charge. Final decision is left to our authorized service technicians. Labor costs are not covered by this warranty and the customer will therefore be charged with the relative amount. Any liability for direct or indirect damages caused to people due to misuse and improper maintenance of this product is not included in this warranty. It is limited to operation and manufacture defects. All parts subject to wear due to their specific use are not covered by this warranty. All transport, on-site, disassembly and reassembly costs due to our technician s intervention are not covered by this warranty and the customer will therefore be charged with the relative amount if defects are not under our liability. 1.4 Standard equipment Instruction and maintenance manual. Wiring diagram. Condensate drain unit (where not already fitted). 1.5 Description The frigorific circuit dryers in this series have been developed in order to eliminate without further expenses and overall dimensions all humidity contained in compressed air by lowering its temperature at about +3 C / 37,4 F. These dryers take advantage of frigorific circuit s features by utilizing freon gas. The air which is obtained is without humidity, while all condensate that accumulated in the condensate separator is discharged on the outside through an electronic programmable discharger, in order to avoid air consumption. The installation s overload, within the maximum use s limits, causes a worsening of dryer s performances (higher dew point), but doesn t prejudice its safety. ATTENTION: the machine is equipped with a power supply - sectioning device (1S1). The Authorized Installer must care for the dryer s correct connection to the power system, according to the Country current norms. A start and stop device (ON/OFF) allows the dryer to be turned on and it permits its normal working. This units are equipped with a frigorific circuit safety system to prevent damages. A cartridge pressure control opens the compressor s contacts at a preset pressure and remains in this position until the reset button is activated. The reset button remains enabled until the line pressure returns to the factory setted safe level. An ammeterical and a thermometrical protection (an authomatic re-establishment on the compressor) prevent from electric and frigorific circuit s damages. 2/19 Cod Rev

3 1.6 Use The use of a dryer is recommended in the treatment of compressed air if a low content of impurities and a high drying is required, such as in the pharmaceutical and food industry or in medical applications. 1.7 General safety instruction Read this manual carefully before performing any operation. This machine has been designed and realized to be used as described below. Any other use is not allowed. Any maintenance or cleaning operation of inner parts has to be performed by specialized staff only. The Suppier is not responsable for any use other than the intended use or not in compliance with the instructions mentioned in this manual. WHAT SHOULD BE DONE: Be familiar with all controls. Before performing any maintenance make sure that the dryer is not connected to the compressed air network (intake and outtake cut-off cocks closed) and no pressure is inside the machine Before removing the protection panels unplug the machine and allow 15 minutes for the inner parts to cool down. Before removing the cooling fan protection grid make sure the dryer is unplugged. Make sure that all protection panels are properly fitted while the machine is working and after any maintenance operation. Make sure that the intake air is free from inflammable fumes or vapours which might cause either explosion or fire risk. WHAT SHOULD NEVER BE DONE: Never place inflammable objects near the dryer. Never use the dryer if the power cable is faulty or the connection is not safe. Never allow anyone to operate the dryer without giving him/her proper instructions. Never make any operation on safety parts. Never hit inner pipes with objects. Never touch any part of the cooling circuit when the machine is running. They are very hot! Never drain the condensate directly into the sewage system. This plant has been designed and realized in compliance with European safety regulations EC 98/37, EEC 73/23 and EEC 89/336. All installation, use and maintenance operations should therefore be perfomed according to the instruction of this manual. Any cleaning/maintenance operation on the dryer should be performed by a qualified and specialized personnel only, fully familiar with precautions to be taken. 2.0 MACHINE UNPACKING AND HANDLING 2.1 Unpacking and handling When supplied the dryer is packed into a suitable cardboard box to be always handled in an upright position using a means with a suitable lifting power (see technical data). After cutting straps (always wear safety gloves and cut them either with scissors or cutting nippers), take the dryer out. Withdraw the package from the top remove the wooden pallet and place the dryer in the choosen position. 2.2 Package disposal We recommend to keep the package so that it can be used again in case the dryer should be moved. Keep it for the warranty period at least. If needed, it will be easier and safer to pack it and send it to the service center. If you decide not to keep the package, it should be delivered to the authorized organization for its disposal. 3/19 Cod Rev

4 3.0 SET-UP 3.1 Machine Positioning - The dryer should be placed in a suitable room with the following features: fully flat floor; protected against weather conditions and direct sun light; properly ventilated, so to keep temperature within 41 F and 104 F even when the dryer is running. It should also be large enough so to have at least one free meter in front of the dryer for a proper machine cooling; properly ventilated since the dryer heats the room up while working. 3.2 Installation - Before any operation check that the pipes to be connected to the dryer are properly clean inside and do not contain any dirt. Install the machine in compliance with the following instructions: Connect the dryer to the air compressed line in compliance with one of the diagrams shown in the fig. 6 and the instructions on labels stuck to the machine and described on page 2. A by-pass structure able to cut the dryer off (disconnection) from the air compressed line is recommended. It will avoid any break in the air supply in case of problems during routine maintenance. Connect the condensate drain tube in compliance with local regulations. The condensate cannot be drained directly into the sewage system since it is a pollutant. A water-oil separator of suitable capacity is therefore recommended. Make sure that voltage and frequency of the electric network are steady and in compliance with data on the machine plate and local regulations of the country in which the dryer is used. Always fit a safety switch in the line. It is up to the customer to decide for its capacity (refer to technical data on the plate). To avoid any deposit of solid particles into the dryer and of oil into the heat exchanger a ceramic filter (QF) before the dryer is always recommended. Aim the dryer so that all controls can be easily read and all maintenance operation easily performed. 3.3 Start-Up Make sure that intake and outtake valves are closed. Turn the door blocking switch (S1) on position 1, in this way the heating system will be activated. Push the (ON/OFF) button on the control panel. Wait for at least 15 minutes until the dryer is steady. Now open the outtake air valve and then open gradually the intake air valve. In this way, the plant is gradually pressurized. If the plant is overloaded over the max. use limits (see technical data), its performance will be remarkably lower but safety will not be in danger. 3.4 Decommissioning - In the case there is the need to move the dryer, proceed as follows: 1. insulate the unit from the compressed air line; 2. if necessary, depressurize the dryer s air circuit by using the condensate drainer (TEST button); 3. insulate the dryer from electricity; 4. disconnect the dryer from electrical feeding; Packing and transport of faulty machines - Repack the dryer in its original box or with a similar one of the same dimensions. The dryer must be kept vertically and packed as supplied from the manufacturer. Do not transport the dryer without its packing, you may damage it irreparably. MATERIALS WITHOUT PACKING AND DOCUMENTS WILL NOT BE ACCEPTED. 4/19 Cod Rev

5 3.5 Control Panel These dryers are equipped with an electronic controller. Please note that the SET POINT & other control parameters have been optimized and factory set. Altough the set point value can be displayed, the ability to alter these factory settings via the digital interface on the front panel has been removed to eliminate the possiblity of unit damage caused by improper settings. A description of the operation of the digital interface is provided below however, to facilitate factory-authorized adjustments. The control panel shown in fig. 2 consists of 5 buttons (ON/OFF, TEST, SET, DOWN and UP) and a three-figure display with three warning LED s shown as 1, 2, 3 and two manometers for low and high refrigerant pressure. DEW POINT fig. 2 Control Panel Status LEDs 1 On = Compressor energized 2 On = Drain valve(s) energized 3 On = Dx solenoid energized Button Functions TEST SET Performs a test of the condensate discharge valve when pressed for more than 3 seconds during the normal operation. Displays the set point value when pressed during normal operation. Stores all changes when pressed after changing set point. DOWN Decreases the displayed value when pressed during set point programming. UP Increases the displayed value when pressed during set point programming. ON/OFF Activates or deactivates unit operation when pressed for 3 seconds. When deactivated, the OFF message is displayed. Set Point Modification Press the SET button (the current set point value is displayed). Modify the displayed set point value by using the UP or DOWN button (if modification is not performed in 15 seconds the controller automatically returns to the normal operating display indicating the DEW POINT value). Confirm the new set value by pushing the SET button within 10 seconds of the modification, the flashing of the set point value confirms acceptance of the new data. If the modified data is not confirmed within 10 seconds, the new data will not be stored and the controller will revert to the previous set point. Please note that changes to the set point WILL adversely effect dryer operation and therefore should only be done by authorized technical service personnel. 5/19 Cod Rev

6 Digital Display Message Numeric Value Description Dewpoint Temperature Error Codes The controller recognizes specific types of operational errors. When an error occurs the display shows a flashing alarm message alternating with the current dewpoint value, as described below: Message (flashing) HtA LtA PF1 Cause High Dewpoint Temperature Low temperature alarm Temperature Sensor failure All the alarms except for PF1 are automatically reset when the cause is removed. PF1 must be cleared by switching the unit off and then re-started. PF1 has a priority over all the other displayed messages. 4.0 INTELLIDRAIN ZERO-LOSS DRAIN TRAP 4.1 Operation The IntelliDrain is designed to remove condensate from any compressed air application without air loss. It is completely automatic, and requires no external settings or adjustments. A two-stage condensate level sensor installed in the trap s internal cavity signals both the beginning and the end of the discharge cycle so the trap discharges only liquid and no air is wasted regardless of load. At start-up, purge any air from the trap s inlet connection by pushing the TEST button several times. The factory-installed inlet filter should be examined and cleaned daily for the first week of operation, and monthly thereafter. 4.2 Controls Green LED: Red LED: Pushbutton: Electrical Power ON Discharge Solenoid Energized (valve open) Discharge TEST (Open Valve Manually) 4.3 Maintenance Close the ball valve located on the filter/stop installed at the drain trap inlet. Depressurize the trap by by pushing the TEST button. Unscrew the plug in the end of the filter/stop to access the filter screen. Clean the filter screen with a compressed air jet. Reassemble and open filter/stop valve. 6/19 Cod Rev

7 5.0 MAINTENANCE 5.1 Weekly - Check visually if the condensate is properly drained. 5.2 Monthly - Clean prefilter to remove any possible dirt on the inner filtering element. Proceed as described on Every 6 months Unplug the machine before performing the following: According to room s temperature, quality of the ambient air and at the beginning of summertime, remove the left side panel and clean the condenser with some compressed air and clean the aluminium fins in order to remove possible dust or deposits which might decrease its performance. Check out compressor s power consumption with reference to dryer s back label or the data sheet on this manual (see chapter 7.1). 6.0 TROUBLESHOOTING SYMPTOM POSSIBLE ORIGIN SOLUTION Temperature shown in display is higher than preset value High compressed air inlet temperature High compressed air flow High ambient air temperature Fouled refrigerant condenser Low refrigerant charge Faulty refrigerant compressor Faulty refrigerant solenoid valve Faulty fan thermostat Faulty control relay Refrigerant high pressure switch open Reduce air temperature to within design limits Reduce air flow to within design limits Increase ventilation rate of installation area Clean condenser Locate & repair leak & re-charge Repair or replace Repair or replace Repair or replace Repair or replace Eliminate cause & reset switch Excessive air pressure drop across dryer Inlet/outlet piping reversed Thermostat sensor out of well Faulty thermostat Ambient temperature below freezing Obstruction in air circuit Connect properly Re-install Repair or replace Install dryer in heated space Locate & remove blockage Water present in air downstream of dryer Air by-pass valve open Condensate drain strainer fouled Faulty condensate drain High dew point temperature Close valve Clean strainer Repair or replace See Symptom #1 above Fan doesn't start and/or stop. Faulty fan thermostat / pressostat Low refrigerant charge Low load with low ambient temperature Repair or replace Locate & repair leak & re-charge Install dryer in heated space 7/19 Cod Rev

8 7.0 TECHNICAL FEATURES 7.1 Data Sheet Model UNITS MDX 1500 MDX 1800 MDX 2400 MDX 3000 Air flow rate SCFM Compressor Power HP 8-1/ Power Consumption KW 6,37 8,21 10,51 11,78 Nominal Current* A 9,53 12,4 14,2 19,1 Full Load Current A 13,4 17, ,6 Locked Rotor Current A Power supply V/Ph/Hz 460/3/60 460/3/60 460/3/60 460/3/60 Air connections FLG ANSI 4 ANSI 4 ANSI 4 ANSI 6 Refrigerant type R134a R134a R22 R22 Weight lbs Maximum Air Inlet F Maximum Ambient F Maximum Pressure psig rating conditions of: 100 F & 100 psig air inlet, 100 F ambient, & 38 F leaving dew point 8/19 Cod Rev

9 7.2 Electric Wiring Diagrams MDX POWER WIRING DIAGRAM Cod Rev MDX CONTROL WIRING DIAGRAM 9/19 Cod Rev

10 MDX TERMINAL BLOCKS DIAGRAM MDX COMPONENTS DIPOSITION 10/19 Cod Rev

11 MDX PARTS LIST MDX POWER WIRING DIAGRAM Cod Rev /19 Cod Rev

12 MDX CONTROL WIRING DIAGRAM MDX TERMINAL BLOCKS DIAGRAM 12/19 Cod Rev

13 MDX COMPONENTS DIPOSITION MDX 2400 PARTS LIST 13/19 Cod Rev

14 MDX POWER WIRING DIAGRAM Cod Rev MDX CONTROL WIRING DIAGRAM 14/19 Cod Rev

15 MDX TERMINAL BLOCKS DIAGRAM 15/19 Cod Rev

16 MDX COMPONENTS DIPOSITION MDX 3000 PARTS LIST 7.3 Refrigerat Circuit Diagram 16/19 Cod Rev

17 MDX Cod Rev MDX Cod Rev /19 Cod Rev

18 MDX Cod Rev INSTALLATION LAYOUT 1 Air Compressor 2 Aftercooler 3 Condensate Separator 4 Receiver Tank 5 Automatic Drain 6 Particulate Prefilter 7 Dryer 8 Solenoid Drain Valve 9 Filter 1.0 micron 10 Filter 0.01micron 11 Activated Carbon Filter 12 Water/Oil Separator 18/19 Cod Rev

19 19/19 Cod Rev

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX MDX Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Operation & Maintenance Manual MODELS MDX 800 1000 1200 TABLE OF CONTENTS HOW TO USE THIS MANUAL 2 SYMBOLS 2 WARRANTY 2 1.0

More information

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250 MDX Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap Operation & Maintenance Manual MDX MODELS 18 THRU 250 TABLE OF CONTENTS HOW TO USE THIS MANUAL 2 SYMBOLS 2 WARRANTY

More information

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100 HTD High Temperature Non-Cycling Refrigerated Compressed Air Dryers Operation & Maintenance Manual MODELS HTD 21 thru HTD 100 - TABLE OF CONTENTS - 1.0 GENERAL 2 1.1 How to use this manual 1.2 Symbols

More information

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL DATE OF PURCHASE: MODEL: SERIAL NO.: Record above information from nameplate. Retain this information for future reference.

More information

Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers

Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers Installation, Operation and Maintenance Manual Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, 76-20 and Membrane Air Dryers Model 76-20 Models 76-01, 76-02, 76-10 Figure

More information

INSTRUCTION AND MAINTENANCE MANUAL

INSTRUCTION AND MAINTENANCE MANUAL Code 007758 0 Edit. 0/009 INSTRUCTION AND MAINTENANCE MANUAL DRYERS A A A A READ THIS MANUAL CAREFULLY BEFORE CARRYING OUT ANY OPERATIONS ON THE DRYER. Cod. 007758 0 - Edition 0/009 - CONTENTS PART A:

More information

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A) Code 007806 0 Edit. 0/04 INSTRUCTION AND MAINTENANCE MANUAL DRYERS A - A - A - A 4 (R40A) READ THIS MANUAL CAREFULLY BEFORE CARRYING OUT ANY OPERATIONS ON THE DRYER. Cod. 007806 0 - Edition 0/04 - CONTENTS

More information

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S Polar Air Dryer R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S PDRCF1150029 PDRCF4602000 Instructions Manual TABLE OF CONTENTS 1. Important safety notes - Please read... 1 1.1. Transportation...

More information

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A10

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A10 Code 00773 04 Edit. 03/0 INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A0 READ THIS MANUAL CAREFULLY BEFORE CARRYING OUT ANY OPERATIONS ON THE DRYER. Cod. 00773 04 - Edition

More information

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50 3227447 Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50 GENERAL SAFETY INFORMATION 1. PRESSURIZED DEVICES: This equipment is a pressure containing device.

More information

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual Instructions Manual 1. Important safety notes - Please read... 1 1.1. Transportation... 1 1.2 Positioning... 1 1.3 Installation... 1 1.4 Before operating... 1 1.5 Maintenance by an engineer... 1 1.6 Maintenance

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

MODULAR AUTOMATIC GRANULAR ICE FLAKER

MODULAR AUTOMATIC GRANULAR ICE FLAKER MODULAR AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 03 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having

More information

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL H-Series & 203 THRU 223 SERIES ARROW PNEUMATICS, INC. REGENERATIVE DRYER DIVISION 2111 WEST 21ST STREET BROADVIEW, IL 60155 708-343-9595 708-343-1907

More information

OPERATORS MANUAL. Direct expansion compressed air dryers CONTENTS. Models DFLO 130 DFLO 170 DFLO 220 DFLO 270 DFLO 360 DFLO 420 DFLO 530 DFLO 600

OPERATORS MANUAL. Direct expansion compressed air dryers CONTENTS. Models DFLO 130 DFLO 170 DFLO 220 DFLO 270 DFLO 360 DFLO 420 DFLO 530 DFLO 600 CONTENTS 1. GENERAL INFORMATION 2 1.1 Functional description 2 1.2 Use of the machine in safe conditions 2 2. SAFETY INFORMATION 3 2.1 General safety instruction 3 2.2 Equipment nameplate values 3 2.3

More information

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

NEWGATE TECHNOLOGIES, INC.

NEWGATE TECHNOLOGIES, INC. www W.newgatetechnologies.com NEWGATE TECHNOLOGIES, INC. Installation & Operations Manual SYNERGY Series High Inlet Temperature Refrigerated Air Dryers Models SYNERGY 025 ~ SYNERGY 125 Includes Safety

More information

AUTOMATIC GRANULAR ICE FLAKER

AUTOMATIC GRANULAR ICE FLAKER AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24480 rev. 01 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on choosing a

More information

C C C-600 INSTRUCTION MANUAL ICE CUBES MACHINE. (including: exploded views, part list & diagrams) CUISIMAT

C C C-600 INSTRUCTION MANUAL ICE CUBES MACHINE. (including: exploded views, part list & diagrams) CUISIMAT C-250 - C-400 - C-600 INSTRUCTION MANUAL ICE CUBES MACHINE (including: exploded views, part list & diagrams) Art.no.: *706.025 / *706.040 / *706.060 1 CONTENTS PRECAUTIONS... 2 INSTALLATION... 3-4 OPERATION...

More information

GRF-SERIES REFRIGERATION TYPE NON CYCLING STANDARD

GRF-SERIES REFRIGERATION TYPE NON CYCLING STANDARD Great Lakes Air Products 1515 S. Newburgh Road Westland, MI 48186 PH: 734-326-7080 www.glair.com COMPRESSED AIR DRYER INSTRUCTION MANUAL GRF-SERIES REFRIGERATION TYPE NON CYCLING STANDARD Contents Introduction

More information

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing

More information

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Owner s Manual Refrigerated Compressed Air Dryer Model F-50 Owner s Manual Refrigerated Compressed Air Dryer Model F-50 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all

More information

AQUAMAC MODELS

AQUAMAC MODELS AQUAMAC MODELS 300-500-800-1000 OUR SYSTEMS CONFORM TO EC STANDARD 73/23 CEE - 89/336 INSTRUCTION MANUAL Cod. 71503095/0-5/97 WARNING! THE FOLLOWING OPERATIONS AND THOSE EVIDENCED WITH THE SYMBOL ON THE

More information

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS Dear Customer, Congratulations on having chosen a quality product which will certainly fully meet your expectations. Thank you for having purchased

More information

Refrigerated & Desiccant Compressed Air Dryer Product Selector

Refrigerated & Desiccant Compressed Air Dryer Product Selector Refrigerated & Desiccant Compressed Air Dryer Product Selector ASD and HTD Series Refrigerated Dryer Units DD Series Desiccant Dryer Units Service Parts For faster service and to avoid errors, please use

More information

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252 EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252 ARROW PNEUMATICS, INC. REGENERATIVE DRYER DIVISION 500 NORTH OAKWOOD RD LAKE ZURICH, IL,60047 PHONE # (847)

More information

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series Over 100,000 compressed air users expect more when it comes to their compressed air supply. BOGE air provides them with the air to work. If it is

More information

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer MANUAL INSTALLATION OPERATION MAINTENANCE Regenerative Type Heatless Desiccant Dryer Dryspell Contents 1. Introduction 2 1.1 Design 1.2 Relevant Units 1.3 Statement of Conformity 1.4 Description 1.5 Adsorbant

More information

Refrigerated Compressed Air Dryers

Refrigerated Compressed Air Dryers Refrigerated Compressed Air Dryers 5-6,000 scfm.14-170 m 3 /min Refrigerated Non-Cycling Refrigerated Cycling Refrigerated High Temperature OWS - 210 Sullair Capabilities Sullair Leadership Since 1965,

More information

instructions for use Air Purifier with ionizer _00/

instructions for use Air Purifier with ionizer _00/ Instructions for use Air Purifier with Ionizer 5713710041_00/07.12 H T S R Q L P N O M I H A B C D E U F G Fig. 2 Fig. 3 Fig. 4 2 introduction Thank you for choosing a De Longhi product. Please take a

More information

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment RHP & FHP Series High Pressure Air Treatment Global Air Treatment 2 High Pressure Air Treatment RHP Series Refrigerated Dryers and E Series Filters for 700 900 psig Applications The demand for clean, dry

More information

AUTOMATIC MODULAR ICE FLAKER

AUTOMATIC MODULAR ICE FLAKER AUTOMATIC MODULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 08 It is strictly forbidden to reproduce this instruction manual or any part thereof. 1 5 3 4 Mod. N. V. W 2 2 M8 18 8 18 M8 M8 3 ~ 200

More information

Instruction book for Air dryers

Instruction book for Air dryers Instruction book for Air dryers FD7, FD16, FD30, FD40, FD60, FD80, FD100, FD120, FD160 and FD210 From following serial numbers onwards: FD7/16: AIQ 108 800 FD30/40/60: AIQ 114 800 FD80: AIQ 105 000 FD100:

More information

Refrigerated Compressed Air Dryers 5-6,000 scfm

Refrigerated Compressed Air Dryers 5-6,000 scfm Refrigerated Compressed Air Dryers 5-6,000 scfm Refrigerated Non-Cycling Refrigerated Cycling Refrigerated High Temperature OWS - 210 Sullair Capabilities Sullair Leadership Since 1965, Sullair has been

More information

BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1

BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1 REV. D Cooler is Better! TM USER S MANUAL BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1 American Panel Corporation 5800 S.E. 78th Street, Ocala, Florida 34472-3412 Phone: (352) 245-7055 Fax: (352) 245-0726

More information

AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM

AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM INSTRUCTIONS AND WARNINGS 24481 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear

More information

PROdry. High Inlet. Temperature. refrigerated. compressed air. dryers. Contents. For Sales & Service please contact:

PROdry. High Inlet. Temperature. refrigerated. compressed air. dryers. Contents. For Sales & Service please contact: 7610.724.11B 10/01 INSTRUCTION MANUAL Contents 1.0 INSTALLATION... 2 2.0 OPERATION... 3 3.0 MAINTENANCE... 4 TROUBLESHOOTING GUIDE... 6 SPECIFICATIONS... 7-8 ELECTRICAL SCHEMATICS... 9 DIMENSIONS AND WEIGHTS...

More information

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",

More information

Refrigerating air dryer. ACT ph. EN - User s maintenance and spare parts manual 7425MUM181UL_EN_

Refrigerating air dryer. ACT ph. EN - User s maintenance and spare parts manual 7425MUM181UL_EN_ Refrigerating air dryer ACT 20 500 1ph EN - User s maintenance and spare parts manual 7425MUM181UL_EN_2015-01 Dear Customer, thank you for choosing our product. In order to get the best performances out

More information

AACH50 1/2 HP GALLONS (200 TO 1200L) INSTRUCTION MANUAL

AACH50 1/2 HP GALLONS (200 TO 1200L) INSTRUCTION MANUAL Ideal for ponic System Reservoirs 1/2 HP 53-317 GALLONS (200 TO 1200L) AACH50 INSTRUCTION MANUAL Before operating this appliance, please read the instruction manual thoroughly and keep on file for future

More information

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

More information

CAHT Series Refrigerated Dryers

CAHT Series Refrigerated Dryers CAHT Series Refrigerated Dryers Installation & Operation Maintenance Manual CAHT20 - CAHT50 (-1) 115/1/60 (-2) 20/1/60 MODEL: SERIAL NUMBER: 8740 Pioneer Blvd Santa Fe Springs, CA 90670 Tel. 562-46-95

More information

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL OPERATING AND INSTALLATION MANUAL TANKLESS ELECTRIC WATER HEATER WITH ELECTRO-MECHANICAL FLOW SWITCH» MINI 2» MINI 2.5» MINI 3» MINI 3.5» MINI 4» MINI 6 The Mini series is tested and certified by WQA against

More information

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS REFRIGERATED COMPRESSED AIR DRYER WRA-0050 WRA-0200 WARNING READ ALL INFORMATION IN THIS MANUAL BEFORE BEGINNING INSTALLATION

More information

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

V A C U U M A N D P R E S S U R E T E C H N O L O G Y Medical Air System Totally Oil Free ULTRAAR Series 4 EN ISO 7396-1 / HTM 0201 220V - 400V / 50Hz 60Hz SPECIFICATION ULTRAAR The ULTRAAR Medical Air System Totally Oil Free shall conform to ISO 7396-1 and

More information

1 HP Air Mover. Owner s Manual

1 HP Air Mover. Owner s Manual 1 HP Air Mover Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may

More information

Refrigerating air dryer ACT Air water cooled. EN - User s maintenance and spare parts manual 7425MUM182_EN_

Refrigerating air dryer ACT Air water cooled. EN - User s maintenance and spare parts manual 7425MUM182_EN_ Refrigerating air dryer ACT 20 500 Air water cooled EN - User s maintenance and spare parts manual 7425MUM182_EN_2012-10 CANADA Dear Customer, thank you for choosing our product. In order to get the best

More information

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL OPERATING AND INSTALLATION MANUAL TANKLESS ELECTRIC WATER HEATER WITH ELECTRO-MECHANICAL FLOW SWITCH» MINI 2» MINI 2.5» MINI 3» MINI 3.5» MINI 4» MINI 6 The Mini series is tested and certified by WQA against

More information

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting

More information

Quality Components as a basis for Quality Equipment

Quality Components as a basis for Quality Equipment Above & Beyond Regenerative Type Compressed Air Dryers SPS - Heatless Regenerative Dryers SPEH - External Heated Regenerative Dryers SPBS - Heated Blower Purge Regenerative Dryers Quality Components as

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN

More information

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management Product Data Sheet Refrigerant Dryer -ES 66 (-W) to -ES 660 (-W) with energy saving management Version: 1.6.0 Author: Karsten Unger Datum: 05.07.2016 Field of application Refrigeration dryers of the -ES

More information

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTRUCTION FOR THE USER THC V E OIL BLU INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods

More information

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W) Refrigeration Dryer 66 (-W) bis 2400 (-W) Version: 1.0.1 Author: Karsten Unger Date: 20.09.2013 Field of application Refrigeration dryers of the series are designed for drying compressed air flows up to

More information

MDH Series Air Dryer. User s Guide

MDH Series Air Dryer. User s Guide MDH Series Air Dryer User s Guide Models covered: MDH1 MDH2 MDH3 MDH4 MDH5 MDH6 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS MDH SERIES AIR DRYER! We here at PUREGAS

More information

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual (English) Table of Contents Page General Safety Instructions...2 System Overview...3 RecoverX-CAR Operation

More information

HP / 20(IVR) KW / 15(IVR)

HP / 20(IVR) KW / 15(IVR) MANUAL USE AND MAINTENANCE SILENCED SCREW ROTARY COMPRESSOR UNITS HP - 0 / 0(IVR) KW - / (IVR) Code 00780044 0 Edition 0/0 THIS MACHINE MUST BE CONNECTED TO TWO DIFFERENT POWER SUPPLIES: THREE-PHASE SUPPLY

More information

CHILLER. Model CH3000. Operator s & Installation Manual

CHILLER. Model CH3000. Operator s & Installation Manual CHILLER Model CH3000 Operator s & Installation Manual Release Date: February 14, 2011 Publication Number: 620054173OPR Revision Date: May 08, 2014 Revision: B Visit the Cornelius web site at www.cornelius.com

More information

AUTOMATIC MODULAR ICE-CUBE MAKER

AUTOMATIC MODULAR ICE-CUBE MAKER AUTOMATIC MODULAR ICE-CUBE MAKER INSTRUCTIONS AND WARNINGS 24851 ed. 06-2012 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having

More information

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer Adsorption dryer Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE Regenerative Type Heatless Desiccant Dryer WE REDEFINE COMPRESSED AIR TREATMENT SYSTEMS 5/232 KNG Pudur road, Somayampalayam

More information

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314) DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant

More information

R100 Oil-Less Refrigerant Recovery Unit

R100 Oil-Less Refrigerant Recovery Unit R100 Oil-Less Refrigerant Recovery Unit Operation Manual 1 INTRODUCTION Welcome to simple, efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit, R100. This unit combines

More information

Instructions manual DEHUMID HP50

Instructions manual DEHUMID HP50 Instructions manual DEHUMID HP50 Table of contents 1. Unpacking 3 2. Intended use 3 3. Disposal 3 4. Safety instructions 3 5. Functional principle 4 6. Automatic defrosting system 4 7. Set up and transportation

More information

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G User Manual for EYS 01G Screw-Press Separator Table of Contents Page 1. Introduction 2 2. General Safety Instructions 3 3. Installation 5 4. Start-up

More information

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page 150-3,000 scfm AEHD Series Desiccant Air Dryers AEHD Series Externally Heated Desiccant Air Dryer 150-3,000 scfm Front Page 1 AEHD Series Heated Dryer Externally Heated Desiccant Dryer 150-3,000 scfm Since

More information

User s Information and Installation Instructions

User s Information and Installation Instructions Outdoor Air Conditioner User s Information and Installation Instructions 2-Stage R-410A Split System These units have been designed and tested for capacity & efficiency in accordance with A.H.R.I. Standards.

More information

User Manual. TN1500 Embedding Center. Read Prior to Operation! Always keep this manual near the unit! WP

User Manual. TN1500 Embedding Center. Read Prior to Operation! Always keep this manual near the unit! WP User Manual TN1500 Embedding Center Read Prior to Operation! Always keep this manual near the unit! WP46818 06.02.15 User Manual TN1500-Embedding Center 888.708.5233 Info@TannerScientific.com www.tannerscientific.com

More information

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0

More information

Product Data Sheet Refrigeration Dryer DFX

Product Data Sheet Refrigeration Dryer DFX Version: 1.0.6 Author: Tassilo Tappe Date: 10.07.2012 Field of application Refrigeration dryers of the DFX series are designed for drying compressed air flows up to 14 bar(g) / 16 bar(g) to pressure dew

More information

Refrigerating air dryer ACT ES EN - User s maintenance and spare parts manual 7425MUM320_EN_04.0

Refrigerating air dryer ACT ES EN - User s maintenance and spare parts manual 7425MUM320_EN_04.0 Refrigerating air dryer ACT ES 20 500 EN - User s maintenance and spare parts manual 7425MUM320_EN_04.0 Dear Customer, thank you for choosing our product. In order to get the best performances out of this

More information

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table) 1 2 Warning: - Do not place your hand or any other objects into the air outlet and fan. It could damage the heat pump and cause injuries; - In case of any abnormality with the heat pump, cut off the power

More information

MeacoDry ABC Range Dehumidifiers

MeacoDry ABC Range Dehumidifiers MeacoDry ABC Range Dehumidifiers Thank you for choosing Meaco, we really do appreciate it INSTRUCTION MANUAL [EN] MeacoDry ABC range SAFETY INFORMATION ATTENTION This dehumidifier must not be used in rooms

More information

RNP SERIES 33 F 39 F 1 C 4 C OFF OPERATOR MANUAL

RNP SERIES 33 F 39 F 1 C 4 C OFF OPERATOR MANUAL ON OFF 33 F 39 F 1 C 4 C 3227498 Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP75 RNP100 RNP125 RNP150 RNP200 RNP250 RNP300 RNP400 RNP500 GENERAL SAFETY INFORMATION

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com

More information

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS INGERSOLLrAND AIR COMPRESSORS HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS CAUTION: For HMD Models 84 Through 385 ONLY 1. Remove Dryer Chambers And Protective

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODELS: CH1001-A Operator s & Installation Manual Release Date: August 9, 2002 Publication Number: 620914301 Revision Date: May 6, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

CH250 AND CH251 CHILLERS

CH250 AND CH251 CHILLERS CH250 AND CH251 CHILLERS Operator s & Installation Manual Release Date: April 19, 2004 Publication Number: 620914801 Revision Date: May 15, 2015 Revision: G Visit the Cornelius web site at www.cornelius.com

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632

More information

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 1098 MR4PMUHV Electronic Temperature/Defrost Control with Relay Pack The MR series temperature controls are designed

More information

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International HC7-15-01 Ceramic Tower Heater Operating Instructions 3081955 HC7-15-01 2007 Soleus Air International Thank you for choosing a Soleus Air Ceramic Tower Heater. This owner s manual will provide you with

More information

ACT REFRIGERATING AIR DRYER USER S MAINTENANCE AND SPARE PARTS MANUAL. Air - Water Cooled CANADA 7425MUM182_EN_

ACT REFRIGERATING AIR DRYER USER S MAINTENANCE AND SPARE PARTS MANUAL. Air - Water Cooled CANADA 7425MUM182_EN_ ACT 20-500 REFRIGERATING AIR DRYER EN USER S MAINTENANCE AND SPARE PARTS MANUAL Air - Water Cooled 7425MUM182_EN_2012-02 CANADA -EN EN- ACT 20-500 Dear Customer, thank you for choosing our product. In

More information

BGH Series Hot Surface Ignition Control

BGH Series Hot Surface Ignition Control Installation Instructions BGH Series Issue Date April 14, 2011 BGH Series Hot Surface Ignition Control Application The BASO Gas Products BGH Series Hot Surface Ignition (HSI) control is microprocessor

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL Swimming Pool Heat Pump Swimming Pool Heat Pump INSTALLATION AND USER MANUAL Thank you for choosing our product and trusting our company. This manual is to provide you with necessary information for optimal

More information

CONTENTS. 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling

CONTENTS. 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling CONTENTS 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling 6. Installation 6.1 Plates 6.2 Dimensions 6.3 Location 6.4 Free room 6.5 Installation

More information

VSA Series Air Dryer. User s Guide

VSA Series Air Dryer. User s Guide VSA Series Air Dryer User s Guide Models covered: VSA1 VSA2 VSA3 VSA4 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS VSA SERIES AIR DRYER! We here at PUREGAS are very proud

More information

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable Smart Smart IR model (check applicable) is recognized as serviceable Service instruction SALES DATE MANUFACTURED ON (DATE): SOLD APPROVAL MARK SMART-EN-04 BLAUBERG Company is happy to offer your attention

More information

User s Information and Installation Instructions

User s Information and Installation Instructions Outdoor Air Conditioner User s Information and Installation Instructions 13 SEER R-410A High Efficiency Split System These units have been designed and tested for capacity & efficiency in accordance with

More information

The Highest Quality Compressed air treatment Refrigerant dryers CFM 0.33 to 91.1 M/min

The Highest Quality Compressed air treatment Refrigerant dryers CFM 0.33 to 91.1 M/min The Highest Quality Compressed air treatment Refrigerant dryers 12-3234 CFM 0.33 to 91.1 M/min web: www.accltd.com Air. CompressedAir. BogeAir. Solutions to improve air quality Guidance on the treatment

More information

UFM-T100H US ES CA Power Alarm Test TM

UFM-T100H US ES CA Power Alarm Test TM Alarm Power TM UFM-T100H US ES CA A E F I J K G B C D H L M N O P Q R S T U V W X US 1 3 2 Power Alarm 4 6 5 Power Alarm 7 9 8 Po we Ala r rm Power Alarm 10 11 Po we Po we Ala rm r 12 Pow Ala Ala rm r

More information

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138 7428146 Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138 1.0 SAFETY All compressed gases, including air, can be dangerous.

More information

Excellent performance with low operating costs, Energy saving and environmentally friendly

Excellent performance with low operating costs, Energy saving and environmentally friendly BOGE compressed air centre C 20 LDR 350 air cooled Screw compressor with BOGE energy saving refrigerant compressed air dryer on horizontal compressed air receivers Complete and ready to connect, fully

More information

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com UNPACKING

More information

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series AirCel Heated Regenerative Desiccant Dryers AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed

More information

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL LABORATORY ULTRA ZERO AIR GENERATOR ZAC-ULT Series USER MANUAL 166 Keystone Drive Montgomeryville, PA 18936 Telephone: 215-641-2700 Fax: 215-641-2714 Email: mtgmmville@matheson-trigas.com INT-0261-XX rev

More information

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15 THIS PAGE INTENTIONALLY LEFT BLANK. 2 Operating Instructions and Parts

More information

OPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB

OPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB OPERATION MANUAL Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB EKHBH016AB*** EKHBX016AB*** Indoor unit for hot water heat pump system and options CONTENTS Page Introduction...1

More information

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax A R R O W P N E U M A T I C S Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 F I L T E R S R E G U L A T O R S L U B R I C A T O R S A C C E S S O R I E S H E

More information

AHT EN- -EN REFRIGERATING AIR DRYER USER S MAINTENANCE AND SPARE PARTS MANUAL. Air Cooled ISSUE 2008_06

AHT EN- -EN REFRIGERATING AIR DRYER USER S MAINTENANCE AND SPARE PARTS MANUAL. Air Cooled ISSUE 2008_06 AHT 20-350 REFRIGERATING AIR DRYER -EN USER S MAINTENANCE AND SPARE PARTS MANUAL Air Cooled ISSUE 2008_06 7425MUM020 CANADA Dear Customer, thank you for choosing our product. In order to get the best performances

More information

OPERATION MANUAL. Indoor unit for air to water heat pump and sanitary warm water tank for air to water heat pump system EKHBH007A EKHBX007A

OPERATION MANUAL. Indoor unit for air to water heat pump and sanitary warm water tank for air to water heat pump system EKHBH007A EKHBX007A OPERATION MANUAL Indoor unit for air to water heat pump and sanitary warm water tank for air to water heat pump system EKHBH007A EKHBX007A EKHBH007A*** EKHBX007A*** Indoor unit for air to water heat pump

More information