HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

Size: px
Start display at page:

Download "HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER"

Transcription

1 FORM NO. HFJ-6 Supersedes Form No. PTZ-789 HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER Features The FH**TTT is EcoNet Enabled: This allows the FH**TTT to directly communicate with the EcoNet Smart Home System. The FH**TTT features an Electronic Expansion Valve (EEV) The FH**TTT features a Constant Torque Two-stage motor (ECM) which provides enhanced SEER performance with most Fujitsu outdoor units. Evaporator is constructed of aluminum fins bonded to internally grooved aluminum tubing. Versatile -way convertible design for upflow, downflow, horizontal left and horizontal right applications. Factory-installed indoor coil. Sturdy cabinet construction with 1.0 inch [. mm] of foil faced insulation for excellent sound and insulating characteristics. Field-installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include circuit breakers which meet U.L. and cul requirements for service disconnect. 1 1 / ton [. kw] through ton [17.6 kw] models are between 1 / to 7 inches [1080 to 18 mm] tall and inches [9 mm] deep. All models meet or exceed 0 to 00 CFM [16 to 189 L/s] per ton at. inches [.7 kpa] of external static pressure. Enhanced airflow up to.7" external static pressure. Suitable for application in mobile homes. FH**TTT Constant Torque (ECM) Efficiencies up to 17 SEER Manufactured for Fujitsu General America, Inc. Fairfield, NJ

2 Table of Contents TABLE OF CONTENTS Engineering Features... Model Number Identification... Dimensional Data...-6 Airflow Directional Data...7 Airflow Performance Data Electrical Data Electrical Wiring...19 Accessories...19 Limited Warranty...0 Fujitsu General America, Inc.

3 Engineering Features Engineering Features Equipped standard with an EcoNet Air Handler control board that allows it to directly communicate with the EcoNet Control Center. The EcoNet Control Center serves as the hub of communication for a home s Heating, Cooling, and Water Heating systems, and is required to operate an EcoNet Enabled Heating and Cooling system in fully communicating mode. Selected models equipped with an electronic expansion valve (EEV), which can intelligently change the EEV position based on system demands. By the measurement of the suction pressure via the vapor line pressure transducer (factory installed) and the vapor line thermistor (field connected to the vapor line, but factory provided within the air handler) the EcoNet enabled air handler control calculates the suction superheat at the indoor coil. This calculation permits the air handler control to make decisions for when to open and close the EEV for the purpose of maintaining a predetermined suction superheat. The EEV is equipped with a -pole removable external stator, and inlet and outlet chatleff fittings for optimal serviceability. These valves also have an internal check valve to provide heat pump compatibility. When operating in heating mode, the air handler control will open the EEV completely to permit the check valve to operate and maximize reverse refrigerant flow. The most compact unit design available, all standard heat air handler models only 1 / to 7 inches [1079 to 18 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check. Coils have copper sweat refrigerant connections. Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to inches [1 mm] for 1 1 / inch [8 mm] conduit. Front refrigerant and drain connections. Fujitsu General America, Inc.

4 Model Number Identification F H 1 T T T J M C Product Capacity Width Metering Device Speed Volt Efficiency Controls Fujitsu H = Air Handler =,000 [7.0 kw] 6 = 6,000 [10. kw] 8 = 8,000 [1.07 kw] 60 = 60,000 [17.8 kw] 1 = 1" = " T = TEV T = Constant Torque T = Two-Stage J = 08/0 1 ph S = Standard M = Medium C = Communicating N = Non-Communicating Available TEV Models at J Voltage FH1TTTJMC FH61TTTJMC FH81TTTJMC FH60TTTJMC Fujitsu General America, Inc.

5 Unit Dimensions Dimensional Data Return Air Opening Dimensions Model Cabinet Size Return Air Opening Width (Inches) Return Air Opening Depth/Length (Inches) 1 19 /8 19 / 7 /8 19 / ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE HIGH VOLTAGE CONNECTION 7 /8 [. mm], 1 / [7.8 mm], 1 1 / [0 mm] DIA. KNOCKOUTS. SUPPLY AIR 10 /16 [6 mm] NOTE: CLEARANCE REQUIRED IN FRONT OF UNIT FOR FILTER AND COIL MAINTENANCE. W LOW VOLTAGE CONNECTION /8 [1.9 mm] AND 7 /8 [. mm] KNOCKOUT A H AUXILIARY DRAIN CONNECTION / [19.1 mm] FEMALE PIPE THREAD (NPT) HORIZONTAL APPLICATION ONLY PRIMARY DRAIN CONNECTION / [19.1 mm] FEMALE PIPE THREAD (NPT) AUXILIARY DRAIN CONNECTION / [19.1 mm] FEMALE PIPE THREAD (NPT) UPFLOW/DOWNFLOW APPLICATION ONLY LIQUID LINE CONNECTION COPPER (SWEAT) 19 1 / [9 mm] RETURN AIR OPENING 1 11 /16 [1 mm] VAPOR LINE CONNECTION COPPER (SWEAT) UPFLOW UNIT SHOWN: UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT OR LEFT AIR SUPPLY. Unit Dimensions & Weights Model Size FH**TTT Refrigerant Connections Sweat (In.) [mm] ID Liquid Vapor Unit Height H In. [mm] Unit Width W In. [mm] Supply Duct A In. [mm] Unit Weight/Shipping Weight (Lbs.) [kg] Unit With Coil (Max. KW) 1M /8 [9.] / [19.0] 1 / [1080] 1 1 / [.] 19 1 / [9.] 111/16 [0/7] 61M /8 [9.] / [19.0] 0 1 / [18] 1 1 / [.] 19 1 / [9.] 19/1 [9/66] 81M /8 [9.] 7/8 [.] 7 1 / [18] 1 1 / [.] 19 1 / [9.] 11/1 [6/69] 60M /8 [9.] 7/8 [.] 1 / [110] 1 / [6.] 1 / [8.0] 161/178 [7/81] *Maximum dehumidification airflow. Fujitsu General America, Inc.

6 Dimensional Data Unit Dimensions FIGURE 6 VERTICAL DOWNFLOW & HORIZONTAL RIGHT APPLICATION RAILS DETAIL A ENSURE THE RETAINING CHANNEL IS FULLY ENGAGED WITH THE COIL RAIL FIGURE 7 INDOOR COIL AND DRAIN PAN SET-UP STRAPS TOP AIR STOP HORIZONTAL ADAPTER KIT PRESSURE TRANSDUCER VAPOR LINE CONNECTION AUXILIARY HORIZONTAL DRAIN CONNECTION PRIMARY DRAIN CONNECTION AUXILIARY UPFLOW/DOWNFLOW DRAIN CONNECTION LIQUID LINE CONNECTION ELECTRONIC EXPANSION VALVE (EEV) VERTICAL DRAIN PAN ELECTRONIC EXPANSION VALVE CONTROL 1 /16 [11 mm] 1 /8 [10 mm] 1 /16 [76 mm] 1 /16 [8 mm] 11 /8 [9 mm] 1 1 /16 [7 mm] 1 /8 [ mm] 1 /16 [71 mm] 1 / [1 mm] /8 [16 mm] 6 Fujitsu General America, Inc.

7 Airflow Directional Data Airflow Directional Data UPFLOW DOWNFLOW HORIZONTAL LEFT HAND AIRFLOW HORIZONTAL RIGHT HAND AIRFLOW Fujitsu General America, Inc. 7

8 Airflow Performance Data Airflow Performance Airflow performance data is based on cooling performance with a coil and no filter in place. Select performance table for appropriate unit size, voltage and number of electric heaters to be used. Make sure external static applied to unit allows operation within the minimum and maximum limits shown in table below for both cooling and electric heat operation. For optimum blower performance, operate the unit in the. [8 mm] to.7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of.1 inch [ mm] W.C. external static range. Airflow Operating Limits Model Cabinet Width 1 1 Cooling BTUH x 1,000 Cooling Tons Nominal Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (7. CFM [18 L/s]/1,000 BTUH) (0 CFM [1 L/s]/Ton Nominal) Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (. CFM [16 L/s]/1,000 BTUH) (00 CFM [189 L/s]/Ton Nominal) Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (0.0 CFM [1 L/s]/1,00 BTUH) (60 CFM [170 L/s]/Ton Nominal) Maximum kw Electric Heating & Minimum Electric Heat CFM [L/s] [] 800 [78] 70 [0] [91] [67] 100 [66] 1080 [10] [97] Maximum Electric Heat Rise F [ C] 6 [17.] 1 [10.6] 1-8/ [80] 1600 [7] 10 [680] 10 [709] 0 [10] [911] 1800 [80] 160 [76] [786] [1.] 8 Fujitsu General America, Inc.

9 Airflow Performance Data 08V/0V Airflow Performance Data FH**TTT (Constant Torque (ECM) ) Air Handler FH**TTT 1ME No Heat 1ME with 1kW 1ME No Heat Outdoor Unit (-)A17 Speed From Factory Y1 tap Y tap (-)A17 Y1 tap Y tap (-)A17 Y1 tap Y tap Blower Size HP Size # Speeds 1/ 10x8 1/ 10x8 1/ 10x8 Speed CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] 797 [76] 6 [99] 7 [168] [10] 91 [79] [6] 7 [] 9 [0] [] 09 [0] 177 [8] [9] 6 [67] 6 [8] 0 [8] 0 [7] [9] 67 [18] [00] [71] 79 [] 699 [0] 67 [0] 607 [86] Fujitsu General America, Inc. 9

10 Airflow Performance Data 08V/0V Airflow Performance Data FH**TTT (Constant Torque (ECM) ) Air Handler FH**TTT 1ME with 1kW 61ME No Heat 61ME with 1kW Heater Outdoor Unit Speed From Factory (-)A17 Y1 tap Y tap (-)A176 (-)A176 Y1 tap Y tap Y1 tap Y tap Blower Size HP Size # Speeds 1/ 10x8 / 10x10 / 10x10 Speed CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] 767 [6] 9 [6] 6 [1] [6] 76 [] 670 [16] 60 [8] [6] [8] 8 [0] 776 [66] 69 [11] 99 [8] [17] 10 [9] 96 [] 909 [9] 80 [87] [91] 801 [78] 78 [9] 6 [0] 1 [] [06] 1007 [7] 91 [] 797 [76] 6 [08] Fujitsu General America, Inc.

11 Airflow Performance Data 08V/0V Airflow Performance Data FH**TTT (Constant Torque (ECM) ) Air Handler FH**TTT 61ME No Heat 61ME with 1kW Heater 81ME No Heat 81ME with 1kW Heater 81ME No Heat 81ME with 1kW Heater Outdoor Unit (-)A176 (-)A176 (-)P1760 (-)A178 (-)P1760 (-)A178 (-)P1760 (-)A178 (-)P1760 (-)A178 Speed From Factory Y1 tap Y tap Y1 tap Y tap Y1 tap Y tap Y1 tap Y tap Y1 tap Y tap Y1 tap Y tap Blower Size HP Size # Speeds / 10x10 / 10x10 1/ 10x10 1/ 10x10 1/ 10x10 1/ 10x10 Speed 1 1 CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] 10 [97] 1001 [7] 99 [] 87 [1] [616] 160 [9] 11 [7] 117 [1] 1107 [] [8] 971 [8] 907 [8] 8 [9] [606] 17 [8] 1189 [61] 119 [7] 1087 [1] [08] 7 [7] 68 [06] 97 [8] 8 [] 97 [] [0] [1] 10 [9] 99 [70] 99 [8] [660] 161 [6] 11 [6] 186 [607] 1 [86] [77] 69 [8] 61 [90] 61 [6] [] 0 [0] [61] [07] 1019 [81] 971 [8] 90 [9] [61] 11 [6] 100 [61] 17 [9] 11 [7] [69] 1160 [7] 111 [9] 1080 [10] [78] 166 [767] 180 [76] 19 [706] 1 [6] [8] 110 [8] 1100 [19] 106 [01] [777] 160 [77] 1 [7] 19 [70] 16 [67] Fujitsu General America, Inc. 11

12 Airflow Performance Data 08V/0V Airflow Performance Data FH**TTT (Constant Torque (ECM) ) Air Handler FH**TTT 60ME No Heat 60ME with 1kW Heater 60ME No Heat 60ME with 1kW Heater Outdoor Unit (-)A17 (-)A17 (-)A17 (-)A17 Speed From Factory Y1 tap Y tap Y1 tap Y tap Y1 tap Y tap Y1 tap Y tap Blower Size HP Size # Speeds 1/ 11x11 1/ 11x11 1/ 11x11 1/ 11x11 Speed CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] 171 [67] 10 [61] 18 [89] 118 [8] [77] 11 [71] 160 [689] 106 [66] 1 [6] [6] 176 [60] 11 [7] 11 [] [68] 11 [60] 1 [8] 11 [] 1071 [06] [69] 116 [61] 17 [9] 1190 [6] [8] 1709 [807] 169 [778] 161 [761] 160 [76] [6] 187 [607] 1 [78] 116 [6] [816] 168 [79] 1610 [760] 11 [71] 19 [68] Fujitsu General America, Inc.

13 Airflow Performance Data 08V/0V Airflow Performance Data FH**TTT (Constant Torque (ECM) ) Air Handler FH**TTT 1MT No Heat 61MT No Heat Outdoor Unit (-)A17 (-)A176 Speed From Factory Y1 tap Y tap Y1 tap Y tap Size HP Blower Size / 10 x 10 / 10 x 10 # Speed Speeds 1 1 CFM [L/s] Air Delivery/RPM/Watts (Dry Coil No Filter) 08-0 VAC 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] CFM [L/s] 899 [] 6 [99] 6 [1] 197 [9] 18 [6] RPM Watts CFM [L/s] 88 [17] 69 [97] 70 [69] 99 [] 7 [06] 69 [17] 07 [1] RPM Watts CFM [L/s] 897 [] 88 [91] 781 [69] 70 [9] 67 [18] 61 [9] 6 [66] RPM Watts CFM [L/s] TBD TBD TBD TBD TBD TBD TBD RPM TBD TBD TBD TBD TBD TBD TBD Watts TBD TBD TBD TBD TBD TBD TBD CFM [L/s] 99 [69] 9 [0] 899 [] 8 [0] 807 [81] 7 [6] 70 [] RPM Watts CFM [L/s] 1000 [7] 96 [7] 87 [99] 77 [66] 719 [9] 66 [0] 7 [70] RPM Watts CFM [L/s] 906 [8] 66 [09] 99 [8] 17 [] 7 [06] 6 [171] 08 [1] RPM Watts CFM [L/s] 1178 [6] 1100 [] 107 [99] 999 [71] 911 [0] 86 [07] 816 [8] RPM Watts CFM [L/s] 100 [96] 991 [68] 9 [7] 87 [90] 779 [68] 71 [7] 60 [0] RPM Watts CFM [L/s] 178 [60] 16 [66] 170 [99] 11 [7] 1160 [7] 108 [99] 106 [89] RPM Watts Fujitsu General America, Inc. 1

14 Airflow Performance Data 08V/0V Airflow Performance Data FH**TTT (Constant Torque (ECM) ) Air Handler FH**TTT 81MT No Heat 60MT No Heat Outdoor Unit (-)A178 (-)A1760 Speed From Factory Y1 tap Y tap Y1 tap Y tap Size HP Blower Size / 10 x 10 / 10 x 10 # Speed Speeds 1 1 CFM [L/s] Air Delivery/RPM/Watts (Dry Coil No Filter) 08-0 VAC 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] CFM [L/s] 91 [1] 8 [97] 7 [] 666 [1] 601 [8] [6] 6 [1] RPM Watts CFM [L/s] 1180 [7] 116 [1] 1067 [0] 9 [1] 909 [9] 86 [0] 796 [76] RPM Watts CFM [L/s] 189 [70] 18 [70] 106 [711] 167 [69] 106 [66] 18 [61] 1 [8] RPM Watts CFM [L/s] 18 [60] 1 [8] 118 [8] 110 [] 99 [69] 976 [60] 9 [] RPM Watts CFM [L/s] 169 [78] 16 [767] 18 [78] 1 [79] 101 [708] 10 [688] 1 [67] RPM Watts CFM [L/s] 17 [68] 108 [617] 16 [88] 118 [8] 11 [0] 10 [97] 99 [69] RPM Watts CFM [L/s] 19 [66] 188 [608] 10 [76] 1161 [8] 1089 [1] 109 [86] 96 [] RPM Watts CFM [L/s] 179 [8] 1699 [80] 167 [777] 160 [76] 11 [7] 106 [711] 1 [68] RPM Watts CFM [L/s] 19 [68] 188 [6] 19 [67] 166 [97] 10 [67] 11 [] 1078 [09] RPM Watts CFM [L/s] 1888 [891] 180 [87] 180 [8] 171 [86] 1711 [807] 1666 [786] 16 [766] RPM Watts Notes: Constant Torque motor speed changes. All Constant Torque motors have speed tabs. Speed tab 1 is for continuous fan. Speed tab (low static) and Speed tab (high static) are for lower tonnage. Speed tab (low static) and Speed tab (high static) are for higher tonnage. Constant Torque air handlers are always shipped from factory at Speed tab, except for -8, which is set at Speed tab. For instance, (-)H1T-HM17JA is always shipped at high static -ton airflow (Speed tab ). To change to 1.-ton airflow, move the blue wire to Speed tab or on the Constant Torque motor. The low static Speed tab (lower tonnage) and (higher tonnage) are used for external static below 0." WC. The high static Speed tab (lower tonnage) and (higher tonnage) are used for external static exceeding 0." WC. Move the blue wire to the appropriate Speed tab as required by the application needs. The airflow for continuous fan (Speed tab 1) is always set at 0% of the Speed tab. The above airflow table lists the airflow information for air handlers without heater and air handler with maximum heater allowed for each model. The following formula can be used to calculate the approximate airflow, if a smaller (N kw) than the maximum heater kit is installed. Approximate Airflow = Airflow without heater (Airflow without heater Airflow with maximum heater) x (N kw/maximum heater kw) 1 Fujitsu General America, Inc.

15 Electrical Data Electrical Data Blower Only No Electric Heat FH**TTT Model FH**TTT Voltage Phase* Hertz HP [W] RPM Speeds Circuit Amps. Minimum Circuit Ampacity Maximum Overcurrent Protector 1M 1 1/ M 1 / / M 1 / M 1 / * Blower motors are all single phase motors. Fujitsu General America, Inc. 1

16 Electrical Data Electrical Data With Electric Heat FH**TTT Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Model FH**TTT Heater Model No. Heater kw (08/0V) (80V) PH/HZ No. Elements kw Per Type Supply Circuit Single Circuit Multiple Circuit Circuit Amps. Ampacity Minimum Circuit Ampacity Maximum Overcurrent Protection RXBH-17?0J./.0 1/ SINGLE 10.8/ /18 0/0 RXBH-17?0./.0 1/ SINGLE 10.8/ /18 0/0 RXBH-17?0J.6/.8 1/ SINGLE 17./ /7 /0 RXBH-17?07J./7. 1/ SINGLE 6.0/ /0 /0 RXBH-17?10J 7./9.6 1/ SINGLE.6/ / 0/60 1M 9./1. 1/ SINGLE.1/ /68 60/70 RXBH-17A1J.1/. 1/ MULTIPLE CKT 1 1.0/ / / 6./8. 1/ MULTIPLE CKT 0.1/.7 0 8/ 0/ RXBH-17A07C./7. /60 -. SINGLE 1.0/ / / RXBH-17A10C 7./9.6 /60 -. SINGLE 0.0/ /1 0/ RXBH-17A1C 9./1. / SINGLE 6.1/ /0 /0 NOTES: * Values only. No single point kit available. Electric heater BTUH - (heater watts + motor watts) x.1 (see airflow table for motor watts.) Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. Heater loads are balanced on phase heater kits with or 6 heating elements only. If non-standard fuse size is specified, use next size larger fuse size. J Voltage (0V) single phase air handler is designed to be used with single or three phase 0 volt electric heaters. In the case of connecting -phase power to the air handler terminal block without the heater, bring only two leads to the terminal block. Cap, insulate and fully secure the third lead. If the kit is listed under both single and multiple circuits, the kit is shipped from factory as multiple circuits. For single phase application, Jumper bar kit RXBJ-A1 and RXBJ-A1 can be used to convert multiple circuits to a single supply circuit. Refer to Accessory Section for details. The airflow for continuous fan is set 0% of the cooling airflow.?heater kits connection type. A=Breaker B=Terminal Block C=Disconnect Pull Out 16 Fujitsu General America, Inc.

17 Electrical Data Electrical Data With Electric Heat FH**TTT (Cont.) Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Model FH**TTT 61M 81M Heater Model No. Heater kw (08/0V) (80V) PH/HZ No. Elements kw Per Type Supply Circuit Single Circuit Multiple Circuit Circuit Amps. Ampacity Minimum Circuit Ampacity Maximum Overcurrent Protection RXBH-17?0J./.0 1/ SINGLE 10.8/ /1 0/ RXBH-17?0J.6/.8 1/ SINGLE 17./ /0 0/0 RXBH-17?07J./7. 1/ SINGLE 6.0/ / 0/ RXBH-17?10J 7./9.6 1/ SINGLE.6/ / 0/60 RXBH-17A1J 10.8/1. 1/ SINGLE 1.9/ /80 70/80.6/.8 1/ MULTIPLE CKT 1 17./ /0 0/0 7./9.6 1/ MULTIPLE CKT.6/ /0 /0 1.8/17.0 1/ SINGLE 61.6/ /9 90/100 RXBH-17A18J./.7 1/ MULTIPLE CKT 1.0 1/ / 8./11. 1/ MULTIPLE CKT 0.0 /9 60/60 RXBH-17A07C./7. /60 -. SINGLE 1.0/17..0 /7 /0 RXBH-17A10C 7./9.6 /60 -. SINGLE 0.0/.1.0 0/ 0/ RXBH-17A1C 10.8/1. / SINGLE 0.0/.6.0 /9 /0 RXBH-17A18C 1.8/17.0 / SINGLE.6/ /7 0/60 RXBH-17B0J.6/.8 1/ SINGLE 17./ /0 0/0 RXBH-17B07J./7. 1/ SINGLE 6.0/ / 0/ RXBH-17B10J 7./9.6 1/ SINGLE.6/ / 0/60 RXBH-17?0J.6/.8 1/ SINGLE 17./ /0 0/0 RXBH-17?07J./7. 1/ SINGLE 6.0/ / 0/ RXBH-17?10J 7./9.6 1/ SINGLE.6/ / 0/60 RXBH-17A1J RXBH-17A18J RXBH-A0J 10.8/1. 1/ SINGLE 1.9/ /80 70/80.6/.8 1/ MULTIPLE CKT 1 17./ /0 0/0 7./9.6 1/ MULTIPLE CKT.6/ /0 /0 1.8/17.0 1/ SINGLE 61.6/ /9 90/100./.7 1/ MULTIPLE CKT 1 0./.6.0 1/ 0/ 8./11. 1/ MULTIPLE CKT 1.1/ /9 60/60 1./19. 1/60-8 SINGLE 69./80.0 9/10 100/110 7./9.6 1/ MULTIPLE CKT 1.6/ / 0/60 7./9.6 1/ MULTIPLE CKT.6/ /0 /0 18.0/.0 1/ SINGLE 86./ /10 1/10 RXBH-AJ 6.0/8.0 1/ MULTIPLE CKT 1 8.8/..0 1/7 /0 6.0/8.0 1/ MULTIPLE CKT 8.8/ / 0/ 6.0/8.0 1/ MULTIPLE CKT 8.8/ / 0/ RXBH-17A07C./7. /60 -. SINGLE 1.0/17..0 /7 /0 RXBH-17A10C 7./9.6 /60 -. SINGLE 0.0/.1.0 0/ 0/ RXBH-17A1C 10.8/1. / SINGLE 0.0/.6.0 /9 /0 RXBH-17A18C 1.8/17.0 / SINGLE.6/ /7 0/60 NOTES: * Values only. No single point kit available. Electric heater BTUH - (heater watts + motor watts) x.1 (see airflow table for motor watts.) Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. Heater loads are balanced on phase heater kits with or 6 heating elements only. If non-standard fuse size is specified, use next size larger fuse size. J Voltage (0V) single phase air handler is designed to be used with single or three phase 0 volt electric heaters. In the case of connecting -phase power to the air handler terminal block without the heater, bring only two leads to the terminal block. Cap, insulate and fully secure the third lead. If the kit is listed under both single and multiple circuits, the kit is shipped from factory as multiple circuits. For single phase application, Jumper bar kit RXBJ-A1 and RXBJ-A1 can be used to convert multiple circuits to a single supply circuit. Refer to Accessory Section for details. The airflow for continuous fan is set 0% of the cooling airflow.?heater kits connection type. A=Breaker B=Terminal Block C=Disconnect Pull Out Fujitsu General America, Inc. 17

18 Electrical Data Electrical Data With Electric Heat FH**TTT (Cont.) Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Model FH**TTT 81M 60M Heater Model No. RXBH-A0C* RXBH-AC* Heater kw (08/0V) (80V) PH/HZ No. Elements kw Per Type Supply Circuit Single Circuit Multiple Circuit Circuit Amps. Ampacity Minimum Circuit Ampacity Maximum Overcurrent Protection 1./19. /60 -. SINGLE 0.0/6..0 /6 60/70 7./9.6 /60 -. MULTIPLE CKT 1 0.0/.1.0 0/ 0/ 7./9.6 /60 -. MULTIPLE CKT 0.0/ /9 /0 18.0/.0 / SINGLE 0.0/ /77 70/80 9.0/1.0 / MULTIPLE CKT 1.0/ / 0/ 9.0/1.0 / MULTIPLE CKT.0/ /7 /0 RXBH-17?0J.6/.8 1/ SINGLE 17./ /1 0/ RXBH-17?07J./7. 1/ SINGLE 6.0/ / 0/ RXBH-17?10J 7./9.6 1/ SINGLE.6/ /6 0/60 RXBH-17A1J RXBH-17A18J RXBH-A0J RXBH-AJ 10.8/1. 1/ SINGLE 1.9/ /81 80/90.6/.8 1/ MULTIPLE CKT 1 17./ /1 0/ 7./9.6 1/ MULTIPLE CKT.6/0.0 0 /0 /0 1.8/17 1/ SINGLE 61.6/ /9 90/100./.7 1/ MULTIPLE CKT 1 0./.6.6 1/ 1/./.7 1/ MULTIPLE CKT 1.1/7. 0 /9 60/60 1./19. 1/ SINGLE 69./80.6 9/ /110 7./9.6 1/ MULTIPLE CKT 1.6/ /6 0/60 7./9.6 1/ MULTIPLE CKT.6/0.0 0 /0 /0 18.0/.0 1/ SINGLE 86./ /11 1/10 6.0/8.0 1/ MULTIPLE CKT 1 8.8/..6 /8 /0 6.0/8.0 1/ MULTIPLE CKT 8.8/. 0 6/ 0/ 6.0/8.0 1/ MULTIPLE CKT 8.8/. 0 6/ 0/ 1.6/8.8 1/ SINGLE 10.8/ /16 10/17 RXBH-A0J 7./9.6 1/ MULTIPLE CKT 1.6/ /6 0/60 (60S only) (1800 CFM only) 7./9.6 1/ MULTIPLE CKT.6/0.0 0 /0 /0 7./9.6 1/ MULTIPLE CKT.6/0.0 0 /0 /0 RXBH-17A07C./7. /60 -. SINGLE 1.0/17..6 /8 /0 RXBH-17A10C 7./9.6 /60 -. SINGLE 0.0/.1.6 1/ / RXBH-17A1C 10.8/1. / SINGLE 0.0/.6.6 /9 /0 RXBH-17A18C 1.8/17.0 / SINGLE.6/ /7 0/60 RXBH-A0C* RXBH-AC* RXBH-A0C* (1800 CFM only) RXBH-A0C (60S only) (1800 CFM only) 1./19. /60 -. SINGLE 0.0/6..6 6/6 60/70 7./9.6 /60 -. MULTIPLE CKT 1 0.0/.1.6 1/ / 7./9.6 /60 -. MULTIPLE CKT 0.0/.1 0 /9 /0 18.0/.0 / SINGLE 0.0/ /78 70/80 9.0/1.0 / MULTIPLE CKT 1.0/ / 0/ 9.0/1.0 / MULTIPLE CKT.0/8.9 0 /7 /0 1.6/8.8 / SINGLE 60.0/ /9 90/ /1. / MULTIPLE CKT 1 0.0/.7.6 /0 /0 10.8/1. / MULTIPLE CKT 0.0/.7 0 8/ 0/ NOTES: * Values only. No single point kit available. Electric heater BTUH - (heater watts + motor watts) x.1 (see airflow table for motor watts.) Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. If non-standard fuse size is specified, use next size larger fuse size. J Voltage (0V) single phase air handler is designed to be used with single or three phase 0 volt electric heaters. In the case of connecting -phase power to the air handler terminal block without the heater, bring only two leads to the terminal block. Cap, insulate and fully secure the third lead. If the kit is listed under both single and multiple circuits, the kit is shipped from factory as multiple circuits. For single phase application, Jumper bar kit RXBJ-A1 and RXBJ-A1 can be used to convert multiple circuits to a single supply circuit. Refer to Accessory Section for details. The airflow for continuous fan is set 0% of the cooling airflow.?heater kits connection type. A=Breaker B=Terminal Block C=Disconnect Pull Out 18 Fujitsu General America, Inc.

19 Electrical Wiring Electrical Wiring Power Wiring Field wiring must comply with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinance. Supply wiring must be 7 C minimum copper conductors only. See electrical data for product Ampacity rating and Circuit Protector requirement. Accessories Combustible Floor Base RXHB- Model Cabinet Size 1 Nominal Cooling Capacity-Tons Combustible Floor Base Model Number RXHB-1 RXHB- Jumper Bar Kit Ckt. to 1 Ckt. RXBJ-A1 is used to convert single phase multiple three circuit units to a single supply circuit. Kit includes cover and screw for line side terminals. Jumper Bar Kit Ckt. to 1 Ckt. RXBJ-A1 is used to convert single phase multiple two circuit units to a single supply circuit. Kit includes cover and screw for line side terminals. Note: No jumper bar kit is available to convert three phase multiple two circuit units to a single supply circuit. Auxiliary Horizontal Overflow Pan Accessory RXBM- Auxiliary Horizontal Overflow Pan Accessory Model Number - RXBM-AC8 - RXBM-AC61 Supply and Return Air Sensor Kit RXHT-A0 The RXHT-A0 Thermistor Kit is to be used with the air handler control to monitor the system return and leaving air temperatures. These temperatures can be monitored with the EccoNet communicating thermostat. Grounding This product must be sufficiently grounded in accordance with National Electrical Code (C.E.C. in Canada) and any applicable local ordinance. A grounding lug is provided. Auxiliary Electric Heater Kits RXBH- Heater Kits include circuit breakers which meet UL and cul requirements for service disconnect. See the Electric Heat Electrical Data in this specification sheet for specific Heater Kit Model numbers. External Filter Base RXHF- Model Cabinet Size Coil Model Filter Size In. [mm] 1 0 x 0 [08 x 08] Horizontal Adapter Kit Model Number (Single Qty.) Part Number* RXHF x 0 [6 x 08] RXHF-.70 *Accommodates 1" or " filter Horizontal Adapter Kit Model Number (10-Pack Qty.) 1/61 RXHH-A0 RXHH-A0 x RXHH-A06 RXHH-A06 x RXHH-A0 RXHH-A0 x 10 A B 1.0. Horizontal Adapter Kit RXHH- This horizontal adapter kit is used to convert Upflow/Downflow only models to horizontal flow. See the following table to order proper horizontal adapter kit. External Filter Base RXHF- Model Cabinet Size *Accommodates 1" or " filter Filter Size In. [mm] 1 0 x 0 [08 x 08] Part Number* RXHF-1 x 0 [6 x 08] RXHF-.70 A 19.0 B 1.0. RXHF- Fujitsu General America, Inc. 19

20 Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Fujitsu General America, Inc. will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. Conditional Parts (Registration Required)...Ten (10) Years *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. 0 Fujitsu General America, Inc.

21 Notes Fujitsu General America, Inc. 1

22 Notes Fujitsu General America, Inc.

23 Notes Fujitsu General America, Inc.

24 Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. In keeping with its policy of continuous progress and product improvement, the right is reserved to make changes without notice. PRINTED IN U.S.A. -18 QG FORM NO. HFJ-6 Supersedes Form No. ATZ-0

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows the RHT to directly communicate

More information

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile

More information

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Rheem High Efficiency Modulating EcoNet Enabled Air Handler Air Handlers Series Rheem High Efficiency Modulating EcoNet Enabled Air Handler - Series Constant CFM (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 20.5 SEER The is EcoNet Enabled: This allows

More information

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3 FORM NO. H66- REV. 1 Supersedes Form No. G66-6 Rev. WH1T SERIES Constant Torque (ECM) Efficiencies up to 1 SEER HIGH EFFICIENCY AIR HANDLER Features WH1T feature a Constant Torque motor (ECM) which provides

More information

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor Air Handlers Rheem Air Handlers RHML- Series X-13 (ECM) RHML feature GE s new X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 2 ton [7.0 kw] through 5 ton [17.6

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

Rheem Standard Efficiency Air Handler

Rheem Standard Efficiency Air Handler Air Handlers Rheem Standard Efficiency Air Handler RHSL- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ-544 Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER FB***TS SERIES X-13 (ECM) Motor Efficiencies up to 16 SEER Features Industry Standard R-410A Refrigerant also Suitable for R-22

More information

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Rheem High Efficiency Modulating EcoNet Enabled Air Handler Air Handlers Rheem High Efficiency Modulating EcoNet Enabled Air Handler RHMV- Series Constant CFM Motor (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 20.5 SEER The RHMV Air Handler is part

More information

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant FORM NO. H11-527 REV. 5 Supersedes Form No. H11-527 Rev. 4 AIR HANDLERS (Model with Coil) AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant earth friendly

More information

Ruud High Efficiency Air Handler

Ruud High Efficiency Air Handler Air Handlers Ruud High Efficiency Air Handler RBHP- Series X-13 (ECM) Motor Efficiencies up to 16 SEER Industry Standard R-410A Refrigerant also Suitable for R-22 Applications Models featuring Electric

More information

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Rheem Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check

More information

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-509 REV. 8 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5 kw] through 5 ton [18 kw] models are always just 35

More information

AIR HANDLERS AIR HANDLERS

AIR HANDLERS AIR HANDLERS FORM NO. H11-33 REV. 1 Supersedes Form No. H11-33 AIR HANDLERS AIR HANDLERS RHBL- Efficiency X-13 (ECM) featuring Industry Standard R-410A Refrigerant RHAL- Standard Efficiency PSC featuring Industry Standard

More information

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Ruud Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check

More information

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Rheem Air Handler RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RHAL- Series PSC Motor Efficiencies up to 14. SEER Front or Bottom Return Flow Check Piston for cooling or heat pump

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS AIR HANDLERS FEATURING R-22 REFRIGERANT: (-)HLA Efficiency (-)HSA Standard Efficiency FEATURING EARTH-FRIENDLY R-410A REFRIGERANT: (-)HLL Efficiency (-)HSL Standard Efficiency

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS AIR HANDLERS FEATURING EARTH-FRIENDLY R-410A REFRIGERANT: (-)HKL Premium Efficiency efrigerant WARNING! These instructions are intended as an aid to qualified licensed service

More information

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG: Ameristar TAG: M4AH4E26B1A00AA SUBMITTAL 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE NOTE: 2 CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR

More information

Bosch BVA Series Air Handler

Bosch BVA Series Air Handler Bosch BVA Series Air Handler 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BVA Product Specifications Data subject to change 12.2016 Bosch Thermotechnology Corp. Product Specifications

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS AIR HANDLERS FEATURING EARTH-FRIENDLY R-410A REFRIGERANT: efrigerant (-)HPL Premium 16 SEER Efficiency! RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION!

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS AIR HANDLERS FEATURING EARTH-FRIENDLY R-410A REFRIGERANT: (-)HPL Premium 16 SEER Efficiency efrigerant! RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION!!

More information

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES TP TECH GUIDE TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP 1200-2000 CFM BLOWERS 3-5 TON COILS OPTIONAL ELECTRIC HEATERS ISO 9001 Certified

More information

Bosch BVA Series Air Handler

Bosch BVA Series Air Handler Bosch BVA Series Air Handler --- Ton Capacity R0A Product Specifications Product Specifications BVA Series Air Handler --- Ton Capacity R0A Air Handler Features Multi-speed ECM blower motor. Factory-installed

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-552 MULTI POSITION GAS FURNACE 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 92% residential gas furnace CSA certified 4 way multi-poise design 7-Segment LED all

More information

Modular Multi-position Air Handler

Modular Multi-position Air Handler Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

RHEEM Split Systems Condensers All submitted condensers meet the 15 SEER minimum All submitted condensers meet the 208/230V specification All submitted condensers contain enhanced mufflers to help dissipate

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

FEM4X. Product Specifications FAN COILS /14/15

FEM4X. Product Specifications FAN COILS /14/15 ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS 1 1/2 thru 5 tons Available for environmentally sound R 410A systems Factory installed TXV metering device Sweat connections Aluminum Tube, Aluminum Fin Evaporator

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-537 MULTI POSITION GAS FURNACE FF***PS95 Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 95% residential gas furnace CSA certified 4 way multi-poise design

More information

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105) TECHNICAL GUIDE VARIALE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: N1VS 600-2000 CFM LOWERS 2-5 TON COILS OPTIONAL 1 & 3 φ ELECTRIC HEATERS ISO 9001 Certified Quality Management

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

WAHL A Product Specifications

WAHL A Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Number Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2 Service Literature Corp. 0527 L10 Revised May 2011 CB26UH and CBX26UH Series Table of Contents CB26UH CBX26UH Model Number Information................... 2 Specifications / Electrical Data................

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal

More information

TECHNICAL SPECIFICATIONS B6VMMX

TECHNICAL SPECIFICATIONS B6VMMX TECHNICAL SPECIFICATIONS BVMM Series Air Handler with TV, -, Btuh (Heat Pump & Air Conditioner) R-4A Refrigerant The BVMM Series of air handlers, when combined with our heat pump or air conditioner, offers

More information

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560) ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1½ thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed High Efficiency, 3

More information

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SB TEM4A0B24S21SB TEM4A0B30S31SB TEM4A0B36S31SB TEM4A0C37S31SB TEM4A0C42S41SB TEM4A0C48S41SB TEM4A0C60S51SB The TEM4 series air handler is designed

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace

More information

REM4P, REM4X. Product Specifications

REM4P, REM4X. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT REM4P, REM4X Product Specifications FAN COILS ALL MODELS 2 thru 5 tons Available for environmentally sound R 410A systems Factory installed piston metering device with

More information

CBX32MV (HFC-410A) SERIES UNITS

CBX32MV (HFC-410A) SERIES UNITS Service Literature Corp. 005-L2 Revised November 5, 202 (HFC-40A) SERIES UNITS (icomfort-enabled) NOTICE A thermostat is not included and must be ordered separately. The Lennox icomfort thermostat must

More information

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers Modular Multi-position Air Handlers Black Epoxy Coil TAM4A0A18S11ED TAM4A0A24S21ED TAM4A0A30S21ED TAM4A0A36S31ED TAM4A0B42S31ED TAM4A0C48S41ED TAM4A0C60S51ED Standard Coil TAM4A0A18S11SD TAM4A0A24S21SD

More information

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering device

More information

COMMUNICATING TWO-STAGE VARIABLE SPEED MULTI-POSITION GAS FURNACES

COMMUNICATING TWO-STAGE VARIABLE SPEED MULTI-POSITION GAS FURNACES FORM NO. GFJ-540 COMMUNICATING TWO-STAGE VARIABLE SPEED MULTI-POSITI GAS FURNACES 96% A.F.U.E. Input Rates from 60 to 115 kbtu [11.72 to 33.71 kw] Manufactured for Fujitsu General America, Inc. Fairfield,

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

16 SEER TWO-STAGE AIR CONDITIONERS

16 SEER TWO-STAGE AIR CONDITIONERS FORM NO. ATZ-210 Supersedes Form No. ATZ-210 16 SEER TWO-STAGE AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability

More information

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4A Fan Unit. Sizes 001 thru 004 Product Data FH4A Fan Unit Sizes 001 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

FAN UNIT FH4A Sizes 001 thru 004

FAN UNIT FH4A Sizes 001 thru 004 FAN UNIT FH4A Sizes 001 thru 004 PRACTICALITY & PERFORMANCE Reliability, dependability, and great value are built into the FH4A Fan Units. The unit is compact and easy to install, with capacities ranging

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006 Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed PRODUCT SPECIFICATIONS AIR HANDLERS CBA8MV DAVE LENNOX SIGNATURE COLLECTION R-0A Ready - Multi-Position - Variable Speed Bulletin No. 080 August 08 Supersedes March 08 Nominal Capacity -. to Tons Optional

More information

Dimensions H x W x D in. (mm)

Dimensions H x W x D in. (mm) ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Model Series Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,

More information

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560) ENVIRONMENTALLY SOUND REFRIGERANT FXM4X Product Specifications FAN COILS FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Sweat

More information

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SA TEM4A0B24S21SA TEM4A0B30S31SA TEM4A0C36S41SA TEM4A0C42S41SA TEM4A0C48S41SA TEM4A0C60S51SA The TEM4 series air handler is designed for installation

More information

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES INSTALLATION NUAL MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: GENERAL.............................................. 1 SAFETY................................................ 1 UNIT INSTALLATION.....................................

More information

FXM4X. Product Specifications FAN COILS FXM4X

FXM4X. Product Specifications FAN COILS FXM4X ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Copper

More information

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil

More information

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 Due to continuous product improvement, specifications are

More information

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil Specification 2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,

More information

Hydronic Air Handler Powered by Tankless Technology

Hydronic Air Handler Powered by Tankless Technology Integrated Solutions Hydronic Air Handler Powered by Tankless Technology RW1P/RW1T- Series Nominal Heating Capacities: 40-100 kbtu [11.7-29.3 kw] Tankless Water Heater Models: RTG-64DVL indoor direct vent

More information

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7 Multi-Position, Variable-Speed Air Handlers 1½ to 5 Tons Standard Features Suitable for use with R-410A and R-22 refrigerants Check flowrater expansion device for cooling and heat pump applications Variable-speed

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4A Fan Unit. Sizes 001 thru 004 Product Data FH4A Fan Unit Sizes 00 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,

More information

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers Modular Multi-position Air Handlers TAM4A0A18S11SA TAM4A0A24S21SA TAM4A0A30S21SA TAM4A0A36S31SA TAM4A0B42S31SA TAM4A0C48S41SA TAM4A0C60S51SA PUB. NO. 22-1848-01 Features and Benefits Air-Tite II TM Cabinet

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw) Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. ) FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features

More information

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-538 Supersedes Form No. GTZ-503 Rev. 1 TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 95% A.F.U.E. ) 95% A.F.U.E. MULTI POSITION GAS FURNACES Features

More information

CB X 32 mv

CB X 32 mv PRODUCT SPECIFICATIONS AIR HANDLERS CBXMV DAVE LENNOX SIGNATURE COLLECTION R-0A Ready - Multi-Position - Variable Speed Bulletin No. 0 October 0 Supersedes July 0 Nominal Capacity -. to + Tons Optional

More information

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3 FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace

More information

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 Check flowrater for heat pump and cooling-only applications All-aluminun tube/aluminum

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

Multi-Position Gas Furnaces

Multi-Position Gas Furnaces MODEL: Multi-Position Gas Furnaces FORM NO. GSC-552 Rev. 1 Sure Comfort 92% A.F.U.E. Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] 92% residential gas furnace

More information

CWA4 Chilled & Hot Water Fan Coil

CWA4 Chilled & Hot Water Fan Coil CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000

More information

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg) FCM4X Product Specifications FAN COILS WITH OBSERVERt COMMUNICATING CONTROL ALL MODELS S 2, 3, 4, and 5 Tons S Multi- position installation S Communicating, self configuring when used with Observer Communicating

More information

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed PRODUCT SPECIFICATIONS AIR HANDLERS CBXMV DAVE LENNOX SIGNATURE COLLECTION R-0A Ready - Multi-Position - Variable Speed Bulletin No. 0 February 08 Supersedes November 07 Nominal Capacity -. to + Tons Optional

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006 Product Data FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant Sizes 002 thru 006 A02332 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4B the most advanced air

More information

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat) ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400

More information

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-540 Supersedes Form No. GTZ-503 Rev. 1 TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] (All Models 95% A.F.U.E. ) TWO STAGE VARIABLE SPEED MULTI POSITION GAS

More information