intarpack refrigeration centrals intarpack intarpack centrifugal axial self-contained refrigeration centrals MDV / BDV / MDE / BDE series
|
|
- Madeline Black
- 6 years ago
- Views:
Transcription
1 selfcontained refrigeration centrals MDV / BDV / MDE / BDE series refrigeration centrals Selfcontained aircooled refrigeration centrals, designed for indoor or outdoor installation, with minimum space needs. centrals range cors compressor capacity from 4 to 60 HP at positi and negati temperature, in two different constructions: aircooled centrals ha been designed for indoor installation at an engine room. They feature medium pressure motorfans to duct outdoors the hot condensing air flow. High power in small place. Tropicalised design for ambient temperature up to. Rack of hermetic reciprocating or scroll compressors with noise insulation. Minimum maintenance needs, with simple access through removable panels. axial axial aircooled centrals ha been deloped for outdoor installation. Each model has been designed to operate under extreme ambient conditions, featuring acoustic insulated components for lower noise lel.
2 innovati refrigeration solutions High reliability compressors DanfossManeurop hermetic reciprocating and scroll compressors are known for their sturdy construction and high reliability operation, and, by being cooled by the refrigerant, they allow a ry efficient noise insulation. Description Features Selfcontained aircooled refrigeration centrals, from 1 to 3 compressors, for positi and negati temperature applications, featuring control board and electronic regulation (depending on the rsion) with control of condensing temperature. R404A refrigerant. Hermetic reciprocating or scroll compressors, noise insulated, with discharge muffler (for reciprocating compressor models), mounted on shock absorbers, internal klixon and crankcase heater. Condenser coil made in copper pipes and aluminium fins. Mediumpressure motorfans for rtical or horizontal air discharge for a ducted outlet of condensing hot air. Proportional control of condensation temperature by fan speed control. Refrigeration circuit equipped with high and low pressure switches, ceramic dehydratant filter, liquid receir and sight glass. Full control and power panel, with differential switch for each compressor (in 2 or more compressors units) and for each motorfan (in 2 motorfans units), MCB switch for compressor/s and motorfan/s, and electronic regulation (depending on the rsion). Copeland negati temperature scroll compressors with vapour injection system, provide a higher performance of up to 25% related to standard compressors. Centrifugal motorfan aircooled centrals include motorfans for a ducted outlet of condenser s hot air. Available static pressure (mmwc) As an option system for cooling capacity modulation. Oil separator (already included for 2 scroll compressors negati temperature units). Anticorrosion coil coating. Backflow damper in fan outlet. Protection system for voltage drop and phase failure Air flow (m³/h) Series 5: Cur 1 Series 6: Cur 2 Series 8: Cur 2 Very compact design with 800 mm maximum width Electric board with differential switch (depending on the model) and MCB switch Cooling s on the left side New generation electronic regulation (depending on the rsion) Centrifugal motorfan Tropicalised condensing coil MDVCVF and BDVCVF rsion (featuring cooling capacity modulation) aircooled centrals can be equipped with the system (Variable Refrigerant Capacity),, which adapts the refrigerant flow to the demand of the evaporating units, keeping constant the pressure in suction line. system is composed by a set of pressure and temperature regulation vals able to progressily change compressor cooling capacity from 100% to 10% of its nominal capacity, while reducing the absorbed electrical power. P abs Discharge muffler Noise insulated hermetic compressor 5% 55% P frig 100%
3 refrigeration centrals MDV / BDV series Applications aircooled centrals ha been designed to centralize the cooling production of a set of evaporating units. They ha been deloped to be installed indoors at an engine room and extracting outdoors the condensation hot air through ducts. Vertical discharge assembly (standard) As standard, motorfans are assembled for rtical air outlet with by front and by side maintenance access. cold room +2 ºC process room +12 ºC refrigerated showcase +2 ºC vitrines murales des fruits and légumes +7ºC Condensig hot air extraction duct By front maintenance access refrigerated packaged food display rack +2 ºC Cooling >500 mm Horizontal discharge assembly (as an option) Centrifugal motorfans assembled for horizontal air outlet is an option in these units. This change is possible to be made also in site with no need for special parts. positi temperature central By front maintenance access Cooling Refrigeration scheme MDVCF8 AP mc Refrigeration scheme legend Extraction duct dimensions mv mv Recommended dimensions for metal sheet or fibreglass ducts, depending on equivalent length. 90º elbow estimated equivalent length is also shown. 5 series 6 series 8 series 20m equivalent length: 400 x 300 mm 500 x 400 mm 1000 x 400 mm 40m equivalent length: 400 x 350 mm 600 x 400 mm 1200 x 400 mm 60m equivalent length: 400 x 400 mm 700 x 400 mm 1400 x 400 mm 90º elbow equivalent length: 8 m 10 m 15 m It is recommended to select the grilles for air intake and discharge according to the following instructions: air outlet grille for an air speed not greater than 5 m/s (equivalent to an airflow surface of 0,3 m for series 5, of 0,5 m for series 6 and of 1 m for series 8). Cd vd rl sa rc fl air inlet grille for an air speed not greater than 3 m/s (equivalent to an airflow surface of 0,5 m for series 5, of 1 m for series 6 and of 2 m for series 8). vl cp V rc P BP P vc cp: compressor rc: crankcase heater MV: Centrifugal motorfan cd: condenser fl: DEHYDRATANT filter vl: SIGHT GLASS rl: liquid receir VD: safety val vc: service val MC: electronic microcontroller P: PRESSURE TRANSDUCER ap: HIGH PRESSURE SWITCH bp: LOW PRESSURE SWITCH sa: OIL SEPARATOR (as an option)
4 innovati refrigeration solutions MDV series positi temperature Codification MDV CFM Series Size Capacity CF Electronic rsion. CMF Electromechanical rsion (only for series 5). CVF Cooling capacity modulation rsion. Technical features 400VIII50 Hz, R404A 1 compressor 2 compressors 3 compressors Series / Model Compressor HP Type* Model MDVCF H MTZ50 MDVCF H MTZ64 MDVCF ,5 H MTZ80 MDVCF H MTZ100 MDVCF H MTZ125 MDVCF H MTZ160 MDVCF H MDVCF ,5 H MDVCF H MDVCF H MDVCF H MDVCF H MDVCF H MDVCF H MDVCF H MDVCF H MDVCF H MDVCF H MDVCF H MDVCF H MDVCF H MTZ28 MTZ32 MTZ36 MTZ40 MTZ50 MTZ64 MTZ80 MTZ100 MTZ125 MTZ160 MTZ50 MTZ64 MTZ80 MTZ100 MTZ125 Ambient temp. Cooling capacity (kw)* Evaporating temperature +5 ºC 0 ºC 5 ºC 10 ºC 15 ºC 20 ºC 25 ºC 30 ºC 12,6 10,1 15,1 12,3 24,2 19, ,0 14,7 11, ,9 30, , ,4 49,1 39,5 57,1 47,0 65,1 53,7 7 12,6 10,2 14,9 20,4 25,0 20,1 2 9,1 12,4 10,0 11,1 1 25,6 20,5 30,2 40,8 50,0 40,2 59,1 4 33,6 26,9 39,2 32,9 49,1 39,9 55,8 44,9 66,3 6,9 10,4 12,7 20,6 16,5 2 20,1 7,3 12,7 17,2 21,1 25,6 20,6 33,7 27,3 41,1 49,7 40,2 27,2 21,7 3 26,8 41,2 33,1 46,6 37,6 5 44,7 6,9 5,5 6,6 11,1 16,9 20,6 7,5 5,8 6,6 7,6 1 27,3 22,1 33,8 26,7 41,2 33,4 21,8 17,2 26,7 21,1 33,7 27,0 38,2 30,4 46,5 36,6 5,5 4,3 6,7 8,6 6,8 8,6 4,5 6,7 5,3 6,1 7,0 1 21,7 27,0 33,6 26,8 27,2 21,7 30,7 2 37,6 4,2 3,3 6,8 6,5 4,5 3,3 6,1 7,0 5,5 6,3 8,1 13,0 26,9 21,4 13,1 10,2 1 12,5 21,5 23,8 1 29,8 23,4 2,4 2,9 5,3 4,1 4,7 8,1 10,4 8,2 2,3 2,9 3,5 4,2 6,4 8,2 12,3 16,3 12,4 20,8 16,4 9,7 7,2 12,1 9,2 16,4 12,8 1 13,6 2 18,0 2,3 1,6 2,8 2,0 3,0 3,0 4,5 2,2 1,4 2,8 1,9 3,3 2,4 3,0 3,1 5,7 7,9 8,8 12,0 8,9 15,6 11,8 6,8 6,1 9,1 12,7 17,2 13,0 Nominal power consump. (kw)* Max. absorbed current (A) Available static pressure* (mmwc) Condenser Air flow Weight (m³/h) (kg) LiqGas cooling SPL db(a)* /2 7 /8 67 4,9 22, /2 7 /8 65 6,4 26, /2 1 1/ , /8 1 1/ ,2 32, /8 1 3/ ,0 41, /8 1 3/ , /2 7 /8 60 5,0 23, /2 7 / /2 1 1/8 60 6,7 27, /2 1 1/8 59 8, /8 1 1/ , /8 1 3/ , /8 1 3/ , , ,1 82, ,0 46, ,1 55, , ,1 76, ,5 91, /8 1 5/ /8 1 5/ /8 2 1/ /8 1 3/ /8 1 5/ /8 1 5/ /8 2 1/ /8 2 1 /8 77 As an option Oil separator. Anticorrosion coil coating. Backflow damper in fan outlet. * Cooling capacity at nominal conditions of evaporating temperature 10 ºC (PT), ambient temperature, superheating 10K and subcooling 3K. Available static pressure in extraction ducts. SPL: Sound pressure lel shown in db(a) at 10 metre distance from the souce in free field. Compressor type according to the following nomenclature: H = Hermetic reciprocating compressor.
5 refrigeration centrals negati temperature BDV series Codification BDV CFM Serie Taille Capacité CF/SCF Electronic rsion. CMF/SCMF Electromechanical rsion (only for series 5). CVF Cooling capacity modulation rsion (only for reciprocating compressor models). Technical features 400VIII50 Hz, R404A Series / Model Compressor HP Type* Model Ambient temp. Cooling capacity (kw)* Evaporating temperature 10 ºC 15 ºC 20 ºC 25 ºC 30 ºC 40 ºC Nominal power consump. (kw)* Max. absorbed current (A) Available static pressure* (mmwc) Condenser Air flow Weight (m³/h) (kg) LiqGas cooling SPL db(a)* BDVSCF ZF13KVE 9,7 8,9 7,6 7,1 6,4 4,9 3,5 3,1 2,7 16, /2 1 1/8 59 BDVCF ,5 H NTZ215 11,2 6,7 7,4 2,8 1,9 5,8 29, /2 1 1/8 68 BDVSCF ZF18KVE 13,3 12,4 8,2 6,9 6,6 5,8 5,7 4,9 4,9 5,3 20, /2 1 1/ compressor BDVCF H NTZ271 BDVSCF ,5 BDVSCF ZF24KVE ZF33KVE 1 18,1 16,4 23,1 21,0 15,6 14,2 20,0 1 13,3 17,1 15,8 7,5 10,4 14,5 11,7 7,3 10,1 7,9 7, /2 1 1/ , /2 1 3/8 72 9,9 26, /2 1 3/8 72 BDVSCF ZF40KVE 27,9 25,5 24,1 22,2 20,7 19,1 17,6 16,3 1 12,3 10,0 10,1 32, /2 1 3/8 72 BDVSCF ZF48KVE 32,6 30,7 2 26,7 2 23,0 20,8 19,7 17,6 1 13,6 12, /2 1 5/8 72 BDVCF H NTZ96 13,1 8,1 6,3 6,5 5,0 3,6 3,7 2,6 2,6 1,6 5,0 27, /2 1 1/8 70 BDVCF50216 H NTZ108 11,4 8,9 7,3 7,6 5,8 3,1 2,0 5,7 31, /2 1 1/8 69 BDVCF H NTZ ,5 7, /2 1 1/ compressors BDVSCF BDVSCF BDVSCF ZF13KVE ZF18KVE ZF24KVE 19,5 1 26,5 2 36,1 32,8 1 22,6 31,1 2 14,1 12,8 19,2 18,0 26,6 2 11,8 16,3 1 22,5 20,7 9,7 1 18,8 17,5 7,0 15,5 14,5 9,8 9,8 12,5 10,8 7,9 32, /2 1 3/ , /2 1 3/ ,3 42, /2 1 5/8 75 BDVSCF ZF33KVE 4 42,0 39,9 36,9 34,2 31,6 28,9 26,9 23,4 22,6 20,1 18,8 16,5 15,8 19,8 53, /8 2 1/8 75 BDVSCF ZF40KVE 55,8 51,0 48,2 4 41,4 38,1 3 32,5 27,4 2 20,0 20,2 22, /8 2 1/8 75 BDVSCF ZF48KVE 6 61,4 56,6 53,4 48,8 4 41,6 3 33,3 29,2 27,1 24,1 21,8 27,6 72, /8 2 1/8 75 BDVCF H NTZ ,8 2 30,0 22, ,87 9,8 1 76, /8 2 1/ compressors BDVSCF BDVCF H BDVSCF BDVSCF ZF18KVE NTZ271 ZF24KVE ZF33KVE 40, ,4 51,9 46,5 66,3 62,4 34,7 32,6 46,7 38,1 4 40,5 57,5 54,2 2 27,6 38,2 30,1 38,9 49,5 46,7 2 23,5 31,1 23,3 30,0 42,2 39,9 20,9 20,0 17,5 2 25,5 35,6 33,8 17,6 17,1 1 12,6 22,9 20,4 28,2 14,7 1 18,6 16,1 23,7 17,6 49, ,7 91, ,8 58, ,1 75, /8 2 1/ /8 2 1/ /8 2 1/ /8 2 1/8 75 BDVSCF ZF40KVE ,1 5 56,6 50,7 48,6 43,1 41,3 3 30, , /8 2 1/8 75 As an option Oil separator (already included for 2 scroll compressors and 3 compressors models). Anticorrosion coil coating. Backflow damper in fan outlet. * Cooling capacity at nominal conditions of evaporating temperature 30 ºC (NT), ambient temperature, superheating 10K and subcooling 3K. Available static pressure in extraction ducts. SPL: Sound pressure lel shown in db(a) at 10 metre distance from the souce in free field. Compressor type according to the following nomenclature: H = Hermetic reciprocating compressor. = roll compressor with vapour injection system. * Resctricted model to 42 ºC ambient temperature.
6 innovati refrigeration solutions MDV / BDV series Dimensions series series 6 series Electronic regulation Standard electronic regulation for centrals in their CF and SCF rsions, for compressor/s and motorfan/s control. Electronic regulation Control of up to 3 power steps with suction pressure set point. Proportional control of condensing temperature by fan/s speed variator. External communication module through ModBus protocol and RS485 (as an option).
7 multiservice refrigeration centrals cooling capacity modulation MDVCVF / BDVCVF rsions Cooling capacity modulation Installing example Multiservice centrals, series MDVCVF and BDVCVF, featuring system (Variable Refrigerant Capacity) for cooling capacity modulation on hermetic recirpocating compressors, composed by: Suction pressure val (VP). Bypass pressure val (VC). Thermostatic expansion val for liquid injection (VE). Pressure control switch (IP). Versions of the multiservice centrals: series MDVCVF 6 and 8. series BDVCVF 6 and 8. Multiservice aircooled centrals are specifically designed for cooling production centrlization of a set of positi or negati temperature evaporating units. REFRIGERATED DISPLAYS 0 ºC vp CABINET 10 ºC system: Variable Refrigerant Capacity The system adjusts the refrigerant flow to the demand of the evaporating units, keeping constant the pressure in suction line. For refrigeration centrals with two or more compressors, the system is installed on one of the compressors, which modulates progresily its cooling capacity, while the other compressors are operating as power steps for a progresi modulation of all the unit cooling capacity. The system for two or more compressors features: progresi control of cooling capacity, with no pressure pulses, PI electronic regulation to keep constant the evaporation pressure to the set point, P abs 5% 55% P frig 100% it protects the compressor from motor reheat risk, it keeps the compressing ratio between the secure operating margins. T ev COLD ROOM 0 ºC PROCESS ROOM 12 ºC T set point REFRIGERATED SHOWCASES 0 ºC vp 10% P frig 100% system can be easily set, through a digital display, for a minimum suction pressure/temperature. The system is designed for compressors stop in case of low pressure (pump down) under the minimum set point. t: THERMOSTAT : THERMOSTATIC EXPANSION VALVE : vp: SOLENOID VALVE CONSTANT PRESSURE VALVE Principle scheme VC VP VE
intarpack refrigeration centrals intarpack intarpack centrifugal axial self-contained refrigeration centrals MDV / BDV / MDE / BDE series
selfcontained refrigeration centrals MDV / BDV / MDE / BDE series refrigeration centrals Selfcontained aircooled refrigeration centrals, designed for indoor or outdoor installation, with minimum space
More informationintarpack intarpack axial MDE / BDE series air-cooled condensing units High power in the smallest space. Tropicalised design for ambient temperature
aircooled condensing units intarpack intarpack aircooled compact refrigeration plants have been designed for outdoor installation, with minimum space needs. intarpack range covers compressor from 8 to
More informationCondensing units with inbuilt control board, to be connected to refrigerated cabinets and special evaporating units...
condensing units MDH / DH, MDF / DF series ondensing units ondensing units with inbuilt control board, to be connected to refrigerated cabinets and special evaporating units... intarbox entrifugal condensing
More informationProcess glycol chillers
Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic
More information50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw
Vertical Air-Cooled Split-System Cooling Units Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 50VZ (40PZ/38VZ)
More informationCHAPTER 6 CONDENSING UNITS
CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More informationRoof top SPACE RPC 450Z R407C M011
Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per
More informationwww.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION
More informationCDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.
DEHUMIDIFICATION 9 CDS 80 FUNCTION The CDS 80 works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier and through an evaporator coil. When passing through the
More informationcondenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications
Outdoor condensing unit for direct expansion applications Variable speed propeller fan Cooling ENVIRONMENTALLY HFC R40A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5. to 8.6 kw Use The CL
More informationAir-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a
Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition
More information500 EX Fusion Compressor Series
500 EX Fusion Compressor Series R404A M/T R404A L/T Capacity RANGE 13.8kW - 20.4kW 7.7kW -11.2kW Copeland Fusion Semi-Hermetic Horizontal Scroll Compressors For Medium and Low Temperature Applications
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationChiller units and air-water heat pumps RANGE OPERATING LIMITS
Chiller units and air-water heat pumps Cooling capacity: Heating capacity: 6, to 6,6 kw 8, to 69,4 kw ENVIRONMENTALLY FRIENDLY HFC R407C PROTECTION DE L'ENVIRONNEMENT Silent and compact design Air-conditioning
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationSplit-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.
capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationTechnical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the
More informationRefrigeration Units Product catalogue & selection guide 2011 edition
Refrigeration Units Product catalogue & selection guide 2011 edition Intarcon is born in 2007 as a common initiate of a group of entrepreneurs from leading companies in the refrigeration sector. Our engineering
More informationRoof top SPACE RPC 315Z R407C MA00
Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationTechnical Information
Date of last update: 02-08 Ref: Application Engineering Europe COPELAND SCROLL COMPRESSORS USING VAPOUR INJECTION FOR REFRIGERATION CONTENTS 1 Introduction...1 2 Principle of Operation...1 3 Capacity Effect...2
More informationCIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet
Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140
More informationEKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata
EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata
More informationWATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ
WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5
More informationGPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1
UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationHigh temperature air-to-water heat pumps
Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors
More informationRAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR
AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationprecision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs
next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationKlimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE
Klimaire 16 SEER CENTRAL DUCTED Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units 10 YEAR LIMITED GUARANTEE R410A R E F R I G E R A N T CSM Condensing Units Features Condensing
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More information60 Hz. Catalogue_2016 REFRIGERATION UNITS. - Commercial Range -
60 Hz atalogue_2016 - ommercial Range - RERIGERTION UNITS ommercial monoblocks Tropicalized design for high ambient temperature up to 45º Thermostatic expansion valve Hot gas defrosting Refrigerant load
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationEXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction
Reducted footprint Dual-wall construction Built-in variable frequency drive PLC control Variable speed condenser fan Cooling capacity: 5 to 50 kw Air flow: 1 000 to 12 000 m 3 /h ErP READY Use Precision
More informationApplication guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort
Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS
More informationCompact and silent Scroll compressors All-season operation
Compact and silent Scroll compressors All-season operation Cooling capacity: 40 to 161 kw 410a Cooling only Use The new generation of CONDENCIAT condensation units is the solution for all split-system
More informationApplication Engineering
Revised September, 2006 ECONOMIZED VAPOR INJECTION (EVI) COMPRESSORS INDEX SECTION PAGE 1. Introduction... 1 2. Theory of Operation... 1 3. Nomenclature... 3 4. ARI Low Temperature Ratings... 3 5. Approved
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating
More informationMAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation
Extensive range of chilled water or direct expansion systems Compact and attractive design Energy savings with EC motor and self-regulating control Easy to install Cooling capacity: 10 to 116 k Air flow
More informationAQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual
u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water
More informationAIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS
RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly
More informationCZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or
More informationPrecision air handling cabinets Ciatronic MICRO/EXPAIR
/ Reducted footprint Double-wall construction Built-in voltage variator PLC control Variable speed condenser fan ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5 to
More informationAIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative
More informationRAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS
AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.
More informationNext P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB
Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...
More informationTechnical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Multi-Scroll Air-Cooled Liquid Chillers Nominal cooling capacity: 167-582 kw 50 Hz EKS/BS business The picture refers to the model: EKS - BP / BS/AS 2 The competitive choice Air
More informationFHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions
Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationAquaflair TRAC-TRAF-TRAH
Aquaflair TRAC-TRAF-TRAH 110 400 kw Air-cooled chillers, free-cooling chillers and heat pumps for mission critical applications Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors
More informationKälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10
Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index
More informationMechanical Systems Mechanical Systems
VING IMPRO ALLY NATUR Mechanical Systems 2017 Mechanical Systems E RMANC PERFO Content Rack Units Racks Units Opti OL Indoor Mini Compact OLtec EVO Maxi Compact Flexi Optivell Innovell Econvell Maxivell
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationAir cooled water chillers
Air cooled chillers with screw compressors and axial fans RAH... K/Ka Series - 1 or more refrigerant circuits Cooling capacities from 307 to 1879 kw R-134a R-407C External installation High cooling capacities
More informationGHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES
Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationGHE Dehumidifiers for radiant cooling systems with heat recovery
Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationБольшая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.
Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,
More information> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base
More informationApplication guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort
Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM Providing indoor climate comfort MIL84E-0607 09-2007 Congratulations you have made a wise choice and we feel sure that
More informationMidea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual
Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without
More informationHi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE
Hi-Pres Self Contained A/C Unit TYPE SCU-C & SCU-W Product specifications HI-PRES MARINE & OFFSHORE Contents Introduction..................... 2 Type SCU-W.......................... 2 Type SCU-C...........................
More informationPURESTREAM CHILL-CUBE TM BY FRIULAIR
PURESTREAM CHILL-CUBE TM BY FRIULAIR Air-cooled water chiller Cooling capacity from 0.5 to 6 tons R407C Refrigerant QPS Inspection label certified to CSA standards 2 Year parts warranty The QBE Chill-Cube
More informationPRODUCT GUIDE
PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationAir cooled industrial chillers
Air cooled industrial chillers Main features R410A refrigerant Cooling capacity 5 175 kw Air cooled industrial chillers Models Versions HE High Efficiency Finned coil evaporators submerged in the storage
More informationUltimate energy saving technology
Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today
More informationAquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS
Electronic Control Optimized energy consumption Dehumidifi cation capacity:,7 to 7,7 kg/h Heating and dehumidifi cation of covered pools DESCRIPTION Series are dehumidifi cation units by cooling circuit,
More informationSELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS
SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION
More informationMechanical Heat Pump R515
P.A.Hilton Ltd Mechanical Heat Pump R515 Above: R515 shown fitted with standard wattmeter Stabilises in minutes allowing many tests to be conducted in a typical laboratory period. Allows a complete refrigerant
More informationi-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationintarpack chiller refrigeration chillers MWE / BWE series
refrigeration chillers MWE / BWE series intarpack chiller Aircooled chillers, designed for refrigeration applications with glycol water and brine. intarpack chiller series covers compressor power from
More informationThomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.
Thomas J Kelly Sr. Engineering Instructor Carrier Corporation August 20, 2003 1 SESSION OBJECTIVES At the conclusion of this session you should be able to: 1. Describe the basics principles of refrigeration
More informationCONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY
CONDENSING UNITS. AIR COOLED CONDENSER. CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY SERIES: DXCZ MODELS: 171, 201, 221, 251, 271, 351 371, 401, 451, 501, 701 and 721 COOLING CAPACITIES OF: 4,7
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2
More information4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB
4,5 22,5 kw Air-conditioned server-racks for direct installation into the room technicalcatalogue T_CLSEVO_0113_GB INDEX HIGHLIGHTS... 3 PLANT TYPE... 3 GENERAL CHARACTERISTICS... 5 SERIES IDENTIFICATION...
More informationEnergy Use in Refrigeration Systems
2012 Rocky Mountain ASHRAE Technical Conference Energy Use in Refrigeration Systems PRESENTED BY: Scott Martin, PE, LEED AP BD+C Objectives Understand mechanical refrigeration terms Describe how heat is
More informationSMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB
T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationDANFOSS OPTYMA PLUS INVERTER UNITS
Optyma Plus Inverter Condensing Units Danfoss Optyma Plus Inverter Units are designed with the unique benefits of stepless inverter scroll technology resulting in a 20-30% higher energy efficiency in a
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More information30GT FLOTRONIC AIR-COOLED CHILLERS
30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed
More informationMAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.
Temperature Control Units Water & Oil 30-500 F Portable Chillers Air & Water-Cooled 20-70 F Central Chillers Air & Water-Cooled Packages & Modules 20-70 F Pump Tank Stations Chilled or Tower Water 200-3600
More informationMotor-driven condensing units MTE MTE R-410A
Motor-driven condensing units MTE Outdoor motor-driven condensing units MTE - 0 kw Efficiency and compactness for commercial air conditioning Scroll compressor PLUS R-0A R-0A refrigerant Cooling only Split
More informationPersonalized comfort for offices and shopping malls RANGE OPERATING LIMITS
R-c Personalized comfort for offices and shopping malls iscreet solution in centralized facilities with closed water loop asy installation in false ceiling T-XH-5-I-I SRIPTION Heat Pumps and ooling Units
More informationPressure Enthalpy Charts
Pressure Enthalpy Charts What is a p-h Diagram? A p-h diagram is a diagram with a vertical axis of absolute pressure and a horizontal axis of specific enthalpy. "Enthalpy is the amount of energy in a substance
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationProduct Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)
Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationLZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 +63 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationRMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
RMA ECO-FRIENDLY REFRIGERANT GAS AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the
More informationair systems Roomtop RTC-RTH 15 to 30 - L
air systems Roomtop RTC-RTH 15 to 30 - L york air-conditioning products Roomtop RTC-RTH - L A complete range from 14.6 kw up to 27.0 kw YKN2open Features New YKN2open board Possibility to be installed
More informationNext MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB
6 15 kw Next MTR Air conditioners for Metrology Labs with upflow air delivery technicalcatalogue T_NXTMTR_0511_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3
More informationChapter-8 Capacity Control of Refrigeration Systems
Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control