2 Introducing the NEW UTICA H2O Series... A complete line of Stainless Steel, Single and Dual Indirect Water Heaters, Storage Tanks, and Hydronic Buffer Tanks. Need An Easy Domestic Hot Water Solution With A Low Operating Cost and the Longevity Of Stainless Steel? Utica H2O Stainless Steel Single Indirect Water Heaters Need A Hot Water Solution To Balance Input and Storage While Reducing Short Cycling? Utica H2O Stainless Steel Storage Tanks Need A Hot Water Solution For Use With Chillers, Heat Pumps, and Low Mass Boilers? Utica H2O Stainless Steel Single & Dual Solar Water Heaters (Electric Back-Up can heat the tank if solar heat is unavailable) standard features Capacities (Gallons) Si Need A Hot Water Solution For Solar Applications Or Small Zones? ng Sta W le inle at C ss er oi S H l In te ea d el te ir Utica H2O Stainless Steel Hydronic Buffer Tanks 30, 40, 40L, 50, 60, 60L, 80 & L Stainless Steel Construction Top Connections (For Easy, Neat, Clean Installation) Stainless Steel Dip Tube Thermoplastic Jacket (Won t dent, scratch or corrode) Low Pressure Drop (Ideal For Low Mass Boilers) T & P Valve, Stainless Aquastat Well & Drain Valve (Factory installed-taped and doped) EPS Insulation (Provides Less Than.5 F Per Hour Standby Loss) Large Diameter, Smooth Heat Exchangers - Prevent Buildup (Stainless Steel s Are 25 to 30 Long and 1-1/8 in Diameter) Honeywell L4080B (Shipped Loose) Made in the USA warranty Limited Lifetime Warranty (Residential), 5 Yr. (Commercial) Limited Lifetime Warranty OPTIONS Low Profile 40L & 60L Capacities High Output 80 & 115 Capacities Electric Back-Up Commercial Connections (For increased DHW flow) * 60, 80 & 115 Capacities 80 & 115 Capacities ( Dom., Blr.)
3 S s Bu tain ffe les rt ss an tee ks l S St tai or nle ag ss e St Ta ee nk l 40, 60, 80 & 115 D Sta u W al inle at C ss er o S H il S te ea o el te la r r t er re s c 30, 40, 60, 60L, 80 & , 80 & 115 * 60L Capacities 60, 80 & 115 Capacities 80 & 115 Capacities ( ) (,, 2 ) All Capacities 40, 60, 80 & 115 Capacities
4 Utica H 2 O Stainless Steel Single Indirect Water Heaters Dimensions/Weights Storage Capacity (Gals.) Heating Surface Sq. Ft. Piping Connections NPT Domestic Water In/Out Boiler Water In/Out H2OI30UB /4 1 HOT OUTLET DOM. COLD INLET 3/4" NPT RECIRC. PORT 1 1/2" NPT HOT OUTLET 1 1/4" NPT BOILER SUPPLY 1 1/2" NPT DOM. COLD INLET 9.5 Dimensions & Weights s Height Dia. Shp. Wgt. (Lbs.) H2OI30UB H2OI40UB H2OI40LUB H2OI50UB H2OI60UB H2OI60LUB H2OI80UB H2OI115UB H2OI80CUB H2OI115CUB H2OI80HOUB H2OI115HOUB H2OI80HOCUB H2OI115HOCUB AQUASTAT WELL DRAIN STANDARD UNIT AQUASTAT WELL DRAIN COMMERCIAL UNIT BOILER RETURN BOILER SUPPLY 1 1/4" NPT BOILER RETURN H2OI40UB /4 1 H2OI40LUB /4 1 H2OI50UB 50 3/4 1 H2OI60UB /4 1 H2OI60LUB /4 1 H2OI80UB H2OI115UB H2OI80CUB 80 H2OI115CUB H2OI80HOUB H2OI115HOUB H2OI80HOCUB H2OI115HOCUB Note: Max. Working pressure 150 psi for all capacities. General Information (See Installation, Operation and Maintenance Manual for complete instructions) Max. First Hour Rating Continuous Rating Boiler Output Required Min. Boiler Water Flow Through Pressure Drop Through 140 F 115 F 140 F 115 F (BTU/Hr.) (Gal./Min.) (Ft. Water) H2OI30UB , H2OI40UB , H2OI40LUB , H2OI50UB , H2OI60UB , H2OI60LUB , H2OI80UB , H2OI115UB , H2OI80CUB , H2OI115CUB , H2OI80HOUB , H2OI115HOUB , H2OI80HOCUB , H2OI115HOCUB , Note: All ratings are based on 200 F boiler water supply and 50 F cold water inlet. See installation manual for ratings at different temperatures and flow rates. Specifications subject to change without notice. Equipment Options Certification/ Decoding Factory installed brass drain and relief valves, welded stainless steel cold water dip tube factory installed and pressure tested, Honeywell L4080B aquastat for field installation. (L) Low profile models for applications with low clearances. (C) Commercial models with larger tappings for higher flow rates. (HO) High Output models available to meet greater demand. H2O I=Indirect Capacity: 30=30 Gals. 40=40 Gals. 50=50 Gals. L=Lowboy C=Commercial HO=High Output HOC=High Output 60=60 Gals. Commercial 80=80 Gals. 115=115 Gals. Conforms to UL STD 174 Certified to CAN/CSA STD C22.2 No L UB UB=Utica Boiler
5 Utica H 2 O Stainless Steel Storage Tanks Piping Connections NPT Dimensions/Weights Storage Capacity (Gals.) Cold/Hot Supply/Return Heat Source Pressure SUPPLY TO HEAT SOURCE RETURN FROM HEAT SOURCE H2OST30UB H2OST40UB H2OST60UB H2OST60LUB H2OST80UB COLD WATER INLET HOT OUTLET H2OST115UB TOP CONNECTIONS ALL 1" NPT H2OST80CUB 80 1 H2OST115CUB Note: Max. Working pressure 150 psi for all capacities. 3/4" NPT RECIRC. PORT 1 1/2" NPT HOT OUTLET AQUASTAT WELL DRAIN STANDARD UNITS General Information (See Installation, Operation and Maintenance Manual for complete instructions) Specifications subject to change without notice. Equipment Options Certification/ Decoding Factory installed brass drain and relief valves, welded stainless steel cold water dip tube factory installed and pressure tested, Honeywell L4080B aquastat for field installation. (L) Low profile models for applications with low clearances. (C) Commercial models available for applications with larger connections. H2O ST=Storage ST Tank Capacity: L=Lowboy 30=30 Gals. C=Commercial 40=40 Gals. 60=60 Gals. 80=80 Gals. 115=115 Gals. L UB UB=Utica Boiler 1" NPT SUPPLY TO HEAT SOURCE 1" NPT RETURN FROM HEAT SOURCE Conforms to UL STD 174 Certified to CAN/CSA STD C22.2 No /2" NPT COLD INLET AQUASTAT WELL Schematic Diagram (Typical Installation) 9.5 DRAIN COMMERCIAL UNITS s Dimensions & Weights Height Dia. Shp. Wgt. (Lbs.) H2OST30UB H2OST40UB H2OST60UB H2OST60LUB H2OST80UB H2OST115UB H2OST80CUB H2OST115CUB
6 Utica H 2 O Stainless Steel Buffer Tanks Dimensions/Weights Storage Capacity (Gals.) Piping Connections NPT H2OBT40114UB H2OBT40112UB 40 H2OBT402UB 2 H2OBT60114UB H2OBT60112UB 60 H2OBT602UB 2 H2OBT80112UB H2OBT80114UB 80 H2OBT802UB 2 H2OBT115114UB H2OBT115112UB 115 H2OBT1152UB 2 H2OBT40114WCUB H2OBT40112WCUB 40 H2OBT402WCUB 2 H2OBT60114WCUB H2OBT60112WCUB 60 H2OBT602WCUB 2 H2OBT80114WCUB H2OBT80112WCUB 80 H2OBT802WCUB 2 H2OBT115114WCUB H2OBT115112WCUB 115 H2OBT1152WCUB 2 Note: Max. Working pressure 60 psi for all capacities. H2O40BT114UB H2O40BT112UB H2O40BT2UB H2O60BT114UB H2O60BT112UB H2O60BT2UB H2O80BT114UB H2O80BT112UB H2O80BT2UB H2O115BT114UB H2O115BT112UB H2O115BT2UB Dimensions & Weights Height A B C Shp. Wgt. (Lbs.) 87 (97 WC) 115 (125 WC) 125 (135 WC) 160 (170 WC) General Information (See Installation, Operation and Maintenance Manual for complete instructions) Specifications subject to change without notice. Equipment Options Certification/ Decoding Factory installed brass drain and relief valves, welded stainless steel cold water dip tube factory installed and pressure tested, Honeywell L4080B aquastat for field installation. (WC) With H2O BT=Buffer BT 40 Tank Capacity: 40=40 Gals. 60=60 Gals. 80=80 Gals. 115=115 Gals = NPT WC=With 112= NPT 2=2 NPT WC UB UB=Utica Boiler Conforms to UL STD 174 Certified to CAN/CSA STD C22.2 No
7 UTICA H 2 O Stainless steel Buffer tanks Reduces chiller or boiler short cycling (Short cycling results in reduced operating efficiency and shorter equipment life) Used in systems having several low BTU cooling or heating loads calling at different times Full size tappings on buffer tank for peak performance (,, and 2 ) Used in systems operating below the design load condition, which is most of the time. H 2 O hydraulically decoupled To/From Boiler/Chiller/Heat-Pump To/From System Buffer Tanks Buffer Tank Sizing - Calculating Capacity Utica H 2 O buffer tanks are a simple, cost effective way to improve overall system efficiency by reducing unnecessary equipment short cycling. The recommended capacity or volume of a buffer tank is based on four variables. 1) The duration of the heating or cooling source on time (minutes). The desired length of on time for each run cycle depends on the type of equipment used. Heat pump and chiller manufacturers typically recommend a minimum of 5 to 10 minutes on time, and boiler manufacturers may recommend a minimum of 10 minutes on time. Check with your equipment manufacturer. Generally, the longer the on time, the higher the overall operating efficiency. 2) The minimum rate of heat input (BTU/HR). This is based on the heat pump or chiller output, or the boiler output at the minimum firing rate if the boiler has a variable input system that ramps input down as the demand decreases. 3) The minimum system load (BTU/HR). This is the demand placed on the system with the smallest zone calling for heat. 4) The allowable tank temperature rise (deg. F). This varies depending on the type of heating or cooling system used, and on the design of the distribution system. Chillers may require a tight, (6 deg. F), differential to assure good dehumidification and prevent freezing, heat pumps may require a (10 deg. F) differential to maintain a high COP, and boilers with hydronic heating distribution systems may require a differential anywhere between 10 to 40 deg. F depending on the application. The following formula determines the tank volume: V = T X ( Q heat input - Q min. heat load) Tank temp. rise X 500 V = Buffer tank volume (gallons) Q heat source = heat source output (BTU/HR) Tank temp rise (deg. F) T = desired heat source on cycle (min.) Q min. heat load = heat output to minimum load Water to Water Heat Pump Example: Town and Country Mechanical wants a minimum heat pump on time of 10 minutes. The heat pump output is 46,500 BTU/HR. The smallest zone is a 7,000 BTU/HR bathroom. The allowable temperature differential is 90 to 100 deg. F for the radiant heat zones. V = 10 x (46,500-7,000) (100-90) x 500 = 79.0 Gallons minimum volume. Choose the H2O80BT buffer tank.
8 Utica H 2 O Stainless Steel Dual and Single Solar Water Heaters Dimensions/Weights TOP COIL SUPPLY COLD WATER IN BOTTOM SOLAR COIL RETURN Dimensions & Weights s Height SINGLE COIL Dia. Shp. Wgt. (Lbs.) H2OI60EUB H2OI80EUB H2OI115EUB DUAL COIL TOP COIL RETURN HOT WATER OUT BOTTOM SOLAR COIL SUPPLY TOP COIL 3/8" ID THERMAL WELL 1/2" NPT RECIRC. RETURN PORT TOP HEATING COIL FOR BACKUP BOTTOM COIL 3/8" ID THERMAL WELL BOTTOM HEATING COIL FOR SOLAR DUAL COIL UNITS H2OI60DUB H2OI80DUB H2OI115DUB H2OI60DEUB H2OI80DEUB H2OI115DEUB " X 10" ELECTRICAL BOX 3/8" ID THERMAL WELL DRAIN VALVE ELECTRIC BACKUP UNITS Storage Capacity (Gals.) Top Heating Surface Sq. Ft. SINGLE COIL Bottom Heating Surface Sq. Ft. Piping Connections NPT H2OI60EUB H2OI80EUB 80 1 H2OI115EUB DUAL COIL H2OI60DUB H2OI80DUB H2OI115DUB H2OI60DEUB H2OI80DEUB H2OI115DEUB Note: Max. Working pressure 150 psi for all capacities. General Information (See Installation, Operation and Maintenance Manual for complete instructions) Max. First Hour Rating Continuous Rating Max. Rec. Top Max. Rec. Bottom Min. Boiler Water Flow Through Pressure Drop Through 140 F 115 F 140 F 115 F (Gal./Hr.) (Gal./Hr.) (Gal./Min.) (Ft. Water) SINGLE COIL H2OI60EUB H2OI80EUB H2OI115EUB DUAL COIL H2OI60DUB H2OI80DUB H2OI115DUB H2OI60DEUB H2OI80DEUB H2OI115DEUB Note: All ratings are based on 180 F boiler water supply and 50 F cold water inlet. For Dual units, continuous ratings shown are for the lower coil only. Specifications subject to change without notice. Equipment Options Certification/ Decoding Factory installed brass drain and relief valves, welded stainless steel cold water dip tube factory installed and pressure tested, Honeywell L4080B aquastat for field installation. Removable thermal well to accept a solar control thermostat or thermistor. Dual coil units equipped with two aquastat wells which control each coil independently and built-in recirculation tapping. Units with Electric Back-Up are provided with 4 x 10 electrical box with pre-wired heating element, thermostat, and hi-limit. All electric back-up units provided with 240 volt AC, 3500 watt element. (E) Electric Back-Up models for supplemental heating. H2O 60 D E UB I=Indirect Capacity: D=Dual E=Electrical UB=Utica Boiler 60=60 Gals. Back up 80=80 Gals. (3500 Watts) 115=115 Gals. Conforms to UL STD 174 Certified to CAN/CSA STD C22.2 No PN Rev. 11/13 Contractor Assistance: P.O. Box 4729 Utica, New York tel: fax:
Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk.
Innovative. Efficient. Dependable. Dunkirk. Dunkirk H 2 O - Stainless Steel Single & Dual Indirect Water Heaters - Storage Tanks - Hydronic Buffer Tanks Introducing the NEW Dunkirk H 2 O Series... A complete
More informationDunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk.
Innovative. Efficient. Dependable. Dunkirk. Dunkirk H 2 O - Stainless Steel Single Indirect Water Heaters - Stainless Steel Storage Tanks - Stainless Steel Hydronic Buffer Tanks - Stainless Steel Single
More informationH 2 HYDRONIC BUFFER TANKS INSTALLATION, OPERATION & MAINTENANCE MANUAL
O HYDRONIC BUFFER TANKS INSTALLATION, OPERATION & MAINTENANCE MANUAL 22, 40, 60, 80, 115 Gallon 2 = 2 inch NPT Pipe Connections 112 = 1½ inch NPT Pipe Connections 114 = 1¼ inch NPT Pipe Connections WC
More informationH 2. Hydronic Buffer Tanks INSTALLATION, OPERATION & MAINTENANCE MANUAL MODELS
MODELS OBT402 OBT40112 OBT40114 OBT402WC OBT40112WC OBT40114WC OBT602 OBT60112 OBT60114 OBT602WC OBT60112WC OBT60114WC OBT802 OBT80112 OBT80114 OBT802WC OBT80112WC OBT80114WC OBT1152 OBT115112 0BT115114
More informationINSTALLATION AND OPERATING INSTRUCTIONS
17 West Street West Hatfield, MA 01088 Phone: (413) 247-3380 * (800) 582-8423 Fax: (413) 247-3369 E-mail: info@stiebel-eltron-usa.com SB 150, SB 200 Glass Lined Indirectly Fired Water Heaters With Single
More informationAdvanced Heating & Hot Water Systems. Stainless Steel Indirect & Storage Tanks
Advanced Heating & Hot Water Systems Stainless Steel Indirect & Storage Tanks w w w. h t p r o d u c t s. c o m Stainless Steel Storage Tanks MODEL Height Dimensions Diameter Drain Inlet Outlet Weight
More informationDHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element
Indirect Tanks for Domestic Hot Water New! Single coil tanks with electric element DHW Tanks FOR ALL SOLAR, GEOTHERMAL OR HYDRONIC APPLICATIONS LIMITED LIFETIME W A R R A N T Y Heavy Gauge Steel With Porcelain
More informationINDIRECT FIRED WATER HEATERS
H E A T T R A N S F E R P R O D U C T S INDIRECT FIRED WATER HEATERS RESIDENTIAL COMMERCIAL Heat Transfer Products, Inc., reserves the right to make product changes or updates without notice. Heat Transfer
More informationHeat Pumps COMFORT NEED IT. When You
Heat Pumps COMFORT When You NEED IT COMFORT When You NEED IT SpacePak s Solstice heat pumps are air-to-water reverse cycle heat pumps that use the comfort of Hydronics as the primary source for both heating
More information/99 USA. Installation Manual SU Save These Instructions!
46992 7/99 USA Installation Manual SU 160-200 Save These Instructions! TABLE OF CONTENTS 1 General Guidelines 3 2 Technical Data and Tank Connections 4 3 Transportation and Placement 5 4 Installation 6
More informationIndirect Fired Water Heater
Indirect Fired Water Heater 35-119 Gallon Capacities Features Heavy Duty Construction Hydrastone cement lining provides long tank life Copper-silicon tappings cannot rust or corrode High impact composite
More informationBetter Boilers.
Better Boilers FEATURING OUR IBC SUPREME SUPER COIL 316Ti STAINLESS STEEL HEAT EXCHANGER. From the factory in Vancouver, our uniquely designed and engineered Super Coil VFC Heat Exchanger is the best Heat
More informationSemi-Instantaneous Indirect Fired Water Heater
MODEL BWX Semi-Instantaneous Indirect Fired Water Heater Use Boiler Water Or HTHW To Heat Domestic Water Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone
More informationH 2 INDIRECT-FIRED WATER HEATERS FOR SINGLE WATER HEATER INSTALLATIONS INSTALLATION, OPERATION & MAINTENANCE MANUAL
H 2 O INDIRECT-FIRED WATER HEATERS FOR SINGLE WATER HEATER INSTALLATIONS INSTALLATION, OPERATION & MAINTENANCE MANUAL 30, 40, 50, 60, 80, 85, 115 Gallon L = Low Boy Profile C = Commercial Pipe Connections
More informationH 2. Hot Water Storage/ Booster Tanks. For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL
H 2 O Hot Water Storage/ Booster Tanks For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL 30, 40, 60, 80, 115 Gallon L = Low Boy Profile C = Commercial Pipe Connections Conforms
More informationH 2 O MODELS INSTALLATION, OPERATION & MAINTENANCE MANUAL O60D O80D O115D O60E O80E O60DE O80DE O115DE INDIRECT-FIRED WATER HEATERS
H 2 O MODELS H 2 O60D H 2 O80D H 2 O115D H 2 O60E H 2 O80E H 2 O60DE H 2 O80DE H 2 O115DE INDIRECT-FIRED WATER HEATERS with Dual Coil SOLAR HOT WATER STORAGE TANK Applications Dual Coil Indirect Fired
More informationAT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL
RESIDENTIAL / LIGHT COMMERCIAL ELECTRIC BOILERS Save Money, Save Space, Save the Environment! 100% Efficient Compact Wall Hung Design Zero Emissions, Green Alternative (No Fossil Fuel, No Chimney, No Carbon
More informationWarmth, efficiency, and total peace of mind.
Warmth, efficiency, and total peace of mind. Combi & Heating Boilers Self-Monitoring Self-Adjusting Self-Commissioning High Efficiency, Wall Mounted, Modulating Condensing Boiler with THINK Intelligence
More informationINSTALLATION AND OPERATING INSTRUCTIONS IBC TECHNOLOGIES INDIRECT-FIRED WATER HEATERS
INSTALLATION AND OPE INSTRUCTIONS IBC TECHNOLOGIES INDIRECT-FIRED WATER HEATERS MODELS - IBC 30, IBC 40, IBC 40L, IBC 50, IBC 60, IBC 60L, IBC 80, IBC 115 HIGH OUTPUT MODELS - IBC 80-HO, IBC 80-HO-C, IBC
More informationStainless Steel Indirect Water Heaters
Stainless Steel Indirect Water Heaters 12 Squire Models to Choose From - 6 Standard Models from 30 to 119 Gallons - 6 Solar Models from 65 to 119 Gallons 316L Passivated Stainless Steel Tank 316L High
More informationVersa- Hydro. up to 96% Efficient
Versa- Advanced Heating & Hot Water Systems Hydro up to 96% Efficient The cost effective Versa-Hydro combines space heating, domestic hot water, and total system control into one compact, high efficiency
More informationECO1ZN3P, ECO2ZN4P ECO
WARNING HOT This product may have hot fluid circulating through it. DO NOT TOUCH! SOME UNION NUTS MAY BECOME LOOSE AND CONSEQUENTLY LEAK THROUGH TRANSPORTATION VIBRATION AND HANDLING. DO NOT OVERTIGHTEN
More informationTANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith
TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE A. O. Smith www.hotwater.com A. O. Smith Tankless Advantage ENDLESS HOT WATER * Heating water only as it s being used means you will never run out of
More informationBosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler
Stainless Steel Condensing Boiler Engineering Submittal Sheet Boiler Components Engineering Specifications There shall be provided and installed Bosch Buderus SSB255 SSB 399 SSB512 in quantities of. Bosch
More informationSERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job
SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,
More informationwww.americanwaterheater.com Energy-efficient, plentiful, and endless supply of hot water. Compact size and wall-mounted to free up valuable floor space. SAVE ENERGY. SAVE SPACE. PAGE [ 2 ] American Water
More informationA Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.
New Size Available Menu SL 10-85G3 Express Setup Load Status Supply Supply User Setup Installer Setup Diagnostics Back IBC 5:59 Return Return A Better Boiler Just Got Better Better Boilers High Performance
More informationEco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps
(/) Eco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps The perfect combination for any heat pump or geothermal hydronic heating system. Eco Ultra is the only buffer storage tank that is also a fully
More informationColumbia Boiler Company
EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net
More informationStainless Steel Indirect Water Heaters
Stainless Steel Indirect Water Heaters 12 Squire Models to Choose From - 6 Standard Models from 30 to 119 Gallons - 6 Solar Models from 65 to 119 Gallons 316L Passivated Stainless Steel Tank 304L High
More informationPackaged Semi-Instantaneous Steam Fired Water Heater
MODEL STX Packaged Semi-Instantaneous Steam Fired Water Heater Shell and Tube Style Heater Features Reliable Only high grade materials used in construction to ensure long operating life Heat exchange pressure
More informationHigh Capacity Instantaneous Steam Fired Water Heater
MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and
More informationVe r s a - Hyd ro. 96% Efficient. The cost effec t i ve. ersa-hydro
ersa-hydro Versa- Hydro 96% Efficient The cost effec t i ve Ve r s a - Hyd ro combines space heating, domestic hot water, and total system control into one compact, high efficiency mod-con unit. I n n
More informationTrinity Tft High Efficiency Gas Condensing Boiler & Water Heater
Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: A. Supply and install modulating and condensing boiler(s) as specified herein. Date:
More informationTrinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater
Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: Date: A. Supply and install modulating and condensing boiler(s)/water heater(s)
More informationCaleffi Hydronic Solutions Contact: Rex Gillespie, Director of Marketing Phone: (414)
Caleffi North America, Inc. 3883 W. Milwaukee Road Milwaukee, WI 53208 T: 414.238.2360 F: 414.238.2366 LITERATURE RELEASE Caleffi Hydronic Solutions June 10, 2010 Contact: Rex Gillespie, Director of Marketing
More informationIndirect Fired Water Heaters
Indirect Fired Water Heaters Installation and Operating Manual C US Models: SST150-40 SST250-65 SST300-80 SST450-119 CAUTION: The heat transfer medium must be water or other nontoxic fluid having a toxicity
More informationTANKLESS PRODUCT GUIDE
TANKLESS PRODUCT GUIDE SOLID. STATE. When it comes to building durability into a product, nobody does it like State. In fact, we've tested our water heaters in some of the most hostile environments and
More informationProject Name: Location: Engineer: Contractor: I. GENERAL
Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL I. PRODUCT Rep: Date: A. Supply and install modulating and condensing boiler(s) as specified
More informationEasy Installation & Service
Water Commercial Electric Heavy Duty Water Heaters Heavy Duty Electric commercial water heaters are available in 50 through 175 gallon capacities. All models quick ship from Rheem warehouses no deposit
More informationOwner s Manual Therma-Stor II Heat Recovery System
PO Box 8680 Madison, WI 53708 TS-138C Revised 8/08 Owner s Manual Therma-Stor II Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents 1.
More informationGas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities
Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Capacities W E A R E F R I E N D L Y T O T H E E A R T H Gas Fired DOUBLE-EFFECT Chiller-Heater Absorption Principle Yazaki MG-Series
More informationH 2. Hot Water Storage/ Booster Tanks INSTALLATION, OPERATION & MAINTENANCE MANUAL MODELS OST30 OST40 OST60 OST60L OST80 OST80C OST115 OST115C
MODELS OST30 OST40 OST60 OST60L OST80 OST80C OST115 OST115C O Hot Water Storage/ Booster Tanks For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL 30, 40, 60, 80, 115 Gallon L =
More informationHeat Pump Water Heater
MODEL PBX Heat Pump Water Heater Fully Integrated Heat Pump Water Heater (HPWH) 40-119 Gallon Capacity Features Highest Efficiency Heat Pump transfers heat from surrounding air into the hot water tank
More informationARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL
ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL Manufacturer's Warning To reduce the possibility of injury due to scalding,
More informationINSTALLATION INSTRUCTIONS WINTER/SUMMER KIT
INSTALLATION INSTRUCTIONS WINTER/SUMMER KIT HYDRONIC HEATING WITH THE SOLAR WATER HEATER This winter/summer kit provides the necessary components for connections to a boiler. Through the proper installation
More informationTWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler
D E S I G N E D T O L E A D TWZ/CT/ODV Series Oil-Fired Hot Water Boilers (Less Tankless Heater) Installation Supplement for boilers equipped with honeywell L7248L 2012 Compliant boiler control These instructions
More informationLOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC
LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC COLD CLIMATES REFERRING SPECIFICALLY TO CLIMATES ZONES 6 & 7 HYDRONIC HEATING USING A FLUID TO TRANSFER
More informationTepid Water Delivery System
Provides Tepid Water For Emergency Fixtures Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust or corrode High impact composite
More informationTrinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater
Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: Date: A. Supply and install modulating and condensing boiler(s)/water heater(s)
More informationInstallation & Operation Manual Models: TSU
TSU-I-O Rev A Installation & Operation Manual Models: TSU 150-940 CAUTION: This appliance is not intended for potable water. This manual must only be used by a qualified heating installer / service technician.
More informationInstallation & Operation Manual Models: SIT030, SIT040, SIT050, SIT065, SIT080, & SIT119
SIT-I-O Rev B Installation & Operation Manual Models: SIT030, SIT040, SIT050, SIT065, SIT080, & SIT119 WARNING This manual must only be used by a qualified heating installer / service technician. Read
More informationTable of Contents. Installation, Operation, and Maintenance Manual V100 Series
V101 EXPANSION TANK CONNECTION WARRANTY ON PUMPS VOID IF RUN DRY! CHECK VALVES INSTALLED IN ALL PUMPS WARNING HOT This product may have hot fluid circulating through it. DO NOT TOUCH! V10 EXPANSION TANK
More informationunion swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve
VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging
More informationTechnical Data Manual Model Nos. and pricing: see Price List
VITOCELL 300-H Indirect-fired domestic hot water storage tank 42 to / 160 to Technical Data Manual Model Nos. and pricing: see Price List Vitocell 300-H EHA Series Horizontal indirect-fired domestic hot
More informationG124X - G234X - G334X Atmospheric Gas Boilers
G124X - G234X - G334X Atmospheric Gas Boilers Setting the Standard for Efficiency High Efficiency: Full line of Atmospheric Gas Boilers Flexible, Corrosion Resistant GL-180M Cast Iron Limited Lifetime
More informationCommercial Gas Water Heaters
CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable
More informationInstallation & Operation Manual Models: SIT030 - SIT119
SIT-I-O Rev N Installation & Operation Manual Models: SIT030 - SIT119 CAUTION: The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1, as listed in Clinical
More informationMECHANICAL VENTING VERSATILITY
MODULATING ULTRA FORCE HIGH EFFICIENCY POWER VENT The full line of State Modulating Ultra Force High Efficiency Power Vent condensing water heaters has been designed to provide years of dependable service
More informationBosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler
Bosch Buderus SSB800/1000/1000TL Engineering Submittal Sheet Boiler Components C US Engineering Specifications There shall be provided and installed Bosch Buderus Model SSB800 SA, Model SSB1000 SA, Model
More informationCirculators high efficiency ECM Circulators
Circulators high efficiency ECM Circulators Circulators high efficiency ECM Circulators Small ECM circulators now available in North America Grundfos Alpha: Provides constant and proportional differential
More informationPART NO. COMBUSTION AIR TERMINATION CAP
ACCESSORIES FOR SUNSTAR TUBE HEATERS VENT CAP SIDEWALL OR ROOF Unique design prevents back drafts and assists in drawing off and exhausting the products of combustion regardless of wind direction Heavy-gauge
More informationAFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh
WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION
More informationLight Duty Commercial Electric Water Heater
MODEL E Light Duty Commercial Electric Water Heater 6-120 Gallon Capacity, up to 6 KW, Single Phase and Three Phase Open Delta Features Heavy Duty Construction High Efficiency Hydrastone cement lining
More informationResidential & Commercial Water Heating
Advanced Heating & Hot Water Systems High Efficiency Residential & Commercial Water Heating A Product For Every Water Heating Need Mod Con DS VWH Mod Con VWH Elite VWH Plus Light Duty Heavy Duty Gas Fired
More informationSuggested Specifications Prestige Excellence 110
Suggested Specifications Prestige Excellence 110 General Requirements A. Furnish and install (qty) completely assembled, modulating, sealed combustion, high efficiency, combination gas-fired boiler(s)
More informationOutdoor Reset IQ Option Card, p/n
Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...
More informationHeat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.
Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow
More informationOutdoor Reset IQ Option Card, p/n
Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...
More informationIndirect-Fired Water Heaters
Indirect-Fired Water Heaters Premier Series Dual Coil Commercial The growing importance of energy efficiency and today s high fuel prices means there s never been a better time to install an AMTROL Mate
More informationIndustry Best 10 Year Commercial Warranty
Medium Dut y Advanced Heating & Hot Water Systems Single Phase or 3 Phase Operation Field Convertible Models: to 1 Gal. Large Volume 3 Phase Commercial Point of Use Single Phase Only Junction Box & Terminal
More informationPART NO. THROUGH THE ROOF VENT CAP
ACCESSORIES FOR SUNSTAR TUBE HEATERS SIDEWALL VENT CAP Unique design prevents back drafts and assists in drawing off and exhausting the products of combustion regardless of wind direction Heavy-gauge aluminum
More informationCommercial Gas Water Heaters
CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable
More informationBosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler
Bosch Buderus SSB1000TL/TL2/TL3/TL4 Engineering Submittal Sheet Boiler Components C US Engineering Specifications There shall be provided and installed Bosch Buderus Model SSB1000TL in quantities of. Bosch
More informationInstallation & Operation Manual Models:
SJS-I-O Rev C Installation & Operation Manual Models: 60-119 : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss
More informationTechnical Data Manual Model Nos. and pricing: see Price List
Technical Data Manual Model Nos. and pricing: see Price List VITOCELL 300-H EHA Series Indirect-fired domestic hot water storage tank 42 to 119 USG (160 to 450 L) Product may not be exactly as shown Vitocell
More informationMascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing
Mascot Gas-Fired Residential and Commercial Wall-Mounted Boiler Easy Installation, 96% Efficiency, Fully Condensing Mascot is a high-efficiency, wall-mounted boiler available in three BTU sizes 126, 167,
More informationSystems and Tanks. 40 H/V 60 H/V 80 V 115 V 139 V Gallon. Applications Sizing System Design
Systems and Tanks Model size 0 H/V 60 H/V 80 V 5 V 9 V Gallon Applications Sizing System Design Systems In recent years there have been many energy-saving improvements to controls and hydraulics associated
More informationINSTALLATION AND OPERATING INSTRUCTIONS IBC TECHNOLOGIES INDIRECT-FIRED WATER HEATERS
INSTALLATION AND OPE INSTRUCTIONS TECHNOLOGIES INDIRECT-FIRED WATER HEATERS MODELS - 30, 40, 40L, 50, 60, 60L, 80, 115 HIGH OUTPUT MODELS - 80-HO, 80-HO-C, 115-HO, 115-HO-C FOR SINGLE WATER HEATER INSTALLATIONS
More informationRaypak Residential Products
Raypak Residential Products Raypak s Residential Boiler Product Family Raypak revolutionized the boiler market in 1948 with the first innovative high recovery boilers that utilized superior finned copper
More informationGOLD Plus 30/40/60/80
PLUS Line Indirect-Fired Water Heaters Series 3 Manual Installation Startup Maintenance Parts PLUS 100/110/119 GOLD Plus 30/40/60/80 Plus 40/60/80 This manual must only be used by a qualified heating installer/service
More informationPhantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor
PHNTM Floor Standing Heating s Phantom-X 399C/500C Residential High Efficiency Gas s PHNTM399C, PHNTM500C Submittal Sheet Wholesaler Job Name Mechanical Contractor Number Gas Type BTU/hr INPUT BTU/hr OUTPUT
More informationJFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine
JFT Flight Machine Models JFT Flight Machine Options Project Item Quantity CSI Section 00 Approval Date Blower dryer Additional wash section Additional load module Additional unload module (8m) wash down
More informationCommercial Hot Water Maker
Boiler Mate Series Commercial Hot Water Maker Indirect-Fired Water Heaters Models WH-7C and WH-10C 1 INNOVATIVE DESIGN FOR REAL WORLD APPLICATIONS The Boiler Mate Series commercial Hot Water Maker design
More informationHubbell NX500 High Efficiency Gas Condensing Water Heater
Hubbell NX500 High Efficiency Gas Condensing Water Heater Suggested Specification Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep:
More informationGet The Edge Over The Competition with The Summit
Gas-Fired Hydronic Boilers Condensing and Modulating for Low NOx and High Efficiency Get The Edge Over The Competition with The Summit Solve installation problems and significantly reduce running costs
More informationASME Packaged Electric Water Heater
MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long
More informationTable of Contents. Installation, Operation, and Maintenance Manual ELBPxx
Series ELBP8/ELBP30 FUSE C 4Vac R NC NO 0 min 5 Delay Off Actuator GROUND NEUTRAL LIVE Reset R CAUTION 5 VOLTS ONLY 3 4 5 6 7 8 8 Zone Wired Module 4038 Dry Contacts Pump Boiler ELBP50 GROUND NEUTRAL Reset
More informationMarine Coolant Heater Catalog
Marine Coolant Heater Catalog Sure Marine Service, Inc. 5320 28th Ave. N.W. Seattle, WA 98107 (800) 562-7797 (206) 784-9903 Marine Coolant Heater Catalog Introduction... 4 Sizing Considerations... 4 Table
More informationASME Packaged Indirect Fired Water Heater
Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining provides superior protection and tank longevity Heavy duty construction withstands
More informationCOMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY
PRIME COMMERCIAL CONDENSING GAS WATER HEATER 40-119 GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY WATER HEATERS TM (Optional) TM THE ULTIMATE IN CONDENSING GAS WATER HEATING THE PRIME ADVANTAGE Industry's
More informationOPERATION AND INSTALLATION UTILISATION ET INSTALLATION
OPERATI AND INSTALLATI UTILISATI ET INSTALLATI Electric Modulating Micro-Boiler» HydroShark 7» HydroShark 0» HydroShark» HydroShark» HydroShark 9» HydroShark» HydroShark 9» HydroShark HydroShark 7 - HydroShark
More informationWater Heaters. Solar Applications
Water Heaters Applications (Optional) 3-way diverting valve Pump Bypass for Cooling Water Bypass Return STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55 CHESWICK,
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS BT INDIRECT SERIES WATER HEATERS BTI 30, BTI 40, BTI 55, BTI 65, BTI 80, BTI 80-MAX, BTI 119-MAX FOR SINGLE WATER HEATER INSTALLATIONS CAUTION 1. The heat transfer-medium
More informationAM Rapid Recovery Water Heaters
Technical Data Sheet AM Rapid Recovery Water Heaters The Advanced Modular Rapid Recovery water heaters from AERCO provide a complete water heating solution in one convenient package. With a packaged integrated
More informationWood Boiler Plumbing Schematics
Wood Boiler Plumbing Schematics Solo Plus Froling FHG Solo Innova Excel Multi-Fuel 2 TABLE OF CONTENTS Section Page 1.0 Introduction..4 2.0 Plumbing Diagrams....5 2.1 Plumbing Example-Solo/Excel 1........5
More informationMini-Combo id. Model MCH. Installation and Operation Instructions. Induced Draft Residential Gas-Fired Space/Water Heater
Installation and Operation Instructions Document 2101B Installation and Operation Instructions for Mini-Combo id Model MCH Induced Draft esidential Gas-Fired Space/Water Heater Note: This document is to
More informationRESIDENTIAL WATER HEATERS SELECT Power Vent Gas Models (Single Pipe) * Height shown is to top of blower outlet ** All connections 3, increasers or red
WATER HEATERS RESIDENTIAL All Select Models Feature: Long-lasting PEXAN cross-link polymer dip tube C3 technology flammable vapor ignition resistant design Easy-to-light Piezo igniter Durable brass drain
More informationBid Date: Date: Project Name: Model Selected: i200x. Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Accessories: Contractor:
i200x/i201x & i250x/i251x Submittal Data Date: Project Name: Project #: City/St/ZIP: Engineer: Contractor: Bid Date: Model Selected: i200x i250x i201x i251x Fuel Type: Natural Gas Propane Accessories:
More informationApplications and Piping Strategies for Condensing Boilers - Introduction
Applications and Piping Strategies for Condensing Boilers - Introduction Foil 2, 10/2015 Viessmann Manufacturing Applications and Piping Strategies for Condensing Boilers Webinar Objectives: 1. Control
More information