TECHNICAL & SERVICE MANUAL

Size: px
Start display at page:

Download "TECHNICAL & SERVICE MANUAL"

Transcription

1 SPLIT-TYPE, HEAT PUMP AIR CITIERS TECHNICAL & SERVICE MANUAL January 00 No. OC REVISE EITI-A Indoor unit [Model names] PCH-AK PCH-.AK PCH-AK PCH-AK PCH-AK PCH-AK PCH-AKH PCH-.AKH PCH-AKH PCH-AKH PCH-AKH PCH-AKH [Service Ref.] PCH-AK PCH-.AK PCH-AK PCH-AK PCH-AK PCH-AK PCH-AKH PCH-.AKH PCH-AKH PCH-AKH PCH-AKH PCH-AKH Revision: RoHS PARTS LIST is added. Service Ref. of outdoor unit has been modified. Some descriptions have been modified. Please void OC. Note: This manual describes only service data of the indoor units. RoHS compliant products have <> mark on the spec name plate. For servicing of RoHS compliant products, refer to the RoHS Parts List. CTENTS INOOR UNIT TEMP. /OFF REMOTE CTROLLER Model name indication. REFERENCE MANUAL. PART NAMES AN FUNCTIS. SPECIFICATIS. ATA. OUTLINES AN IMENSIS. WIRIN IARAM 8. REFRIERANT SYSTEM IARAM 9 8. TROUBLESHOOTIN 9. FUNCTI SETTIN 0. SYSTEM CTROL 0. ISASSEMBLY PROCEURE. PARTS LIST 9. RoHS PARTS LIST 8. OPTIAL PARTS 8

2 REFERENCE MANUAL -. OUTOOR UNIT S SERVICE MANUAL Service Ref. PUH-/.AKA.TH-A, PUH-/.AKA.TH-A PUH-VKA.TH-A, PUH-VKA.TH-A PUH-YKA.TH-A, PUH-YKA.TH-A PUH-YKSA.TH-A PUH-/YKSA.TH-A, PUH-/YKSA.TH-A PUH-/./VKA.TH, PUH-/./VKA.TH PUH-YKA.TH, PUH-YKA.TH PUH-//YKSA.TH, PUH-/YKSA.TH PUH-/./NKA.TH, PUH-/./NKA.TH PUH-//TKSA.TH, PUH-/TKSA.TH Service Manual No. OC OC OC

3 PART NAMES AN FUNCTIS Indoor Unit Left/right guide vanes Change the direction of airflow from the horizontal blower. Air outlet Long-life filter Removes dust and foreign matter from air coming in through the grille (Recommended cleaning interval : Approx, every,00 operating hours) Up/down guide vanes Change the direction of airflow from the vertical blower. Intake grille Air intake Remote controller Once the controls are set, the same operation mode can be repeated by simply pressing the /OFF button. Operation buttons Set Temperature buttons /OFF button own Up Fan Speed button Timer Menu button (Monitor/Set button) Mode button (Return button) Filter button (<Enter> button) TEMP. /OFF Test Run button Set Time buttons Check button (Clear button) Back MENU /OFF FILTER Ahead Timer On/Off button (Set ay button) BACK PAR-MAA MITOR/SET AY CLOCK OPERATI CHECK TEST CLEAR Airflow Up/own button Louver button ( Operation button) Opening the door To return operation number Ventilation button ( Operation button) To go to next operation number

4 isplay For purposes of this explanation, all parts of the display are shown as lit. uring actual operation, only the relevant items will be lit. Identifies the current operation Shows the operating mode, etc. * Multilanguage display is supported. ay-of-week Shows the current day of the week. Time/Timer isplay Shows the current time, unless the simple or Auto Off timer is set. If the simple or Auto Off timer is set, shows the time remaining. Sensor indication isplayed when the remote controller sensor is used. Locked indicator Indicates that remote controller buttons have been locked. Clean The Filter indicator Comes on when it is time to clean the filter. Centrally Controlled indicator Indicates that operation of the remote controller has been prohibited by a master controller. Timer Is Off indicator Indicates that the timer is off. Temperature Setting Shows the target temperature. F C TIME SUN M TUE WE THU FRI SAT TIMER Hr AFTER AFTER OFF ERROR COE F C LYHr. Up/own Air irection indicator The indicator shows the direction of the outcoming airflow. One Hour Only indicator isplayed if the airflow is set to Low and downward during COOL or RY mode. (Operation varies according to model.) The indicator goes off after one hour when the airflow direction also changes. FUNCTI FILTER WEEKLY SIMPLE AUTO OFF Room Temperature display Shows the room temperature. Louver display Indicates the action of the swing louver. oes not appear if the louver is stationary. (Power On indicator) Indicates that the power is on. Timer indicators The indicator comes on if the corresponding timer is set. Fan Speed indicator Shows the selected fan speed. Ventilation indicator Appears when the unit is running in Ventilation mode. Caution Only the Power on indicator lights when the unit is stopped and power supplied to the unit. If you press a button for a feature that is not installed at the indoor unit, the remote controller will display the Not Available message. If you are using the remote controller to drive multiple indoor units, this message will appear only if the feature is not present at the parent unit. When power is turned for the first time, it is normal that PLEASE WAIT is displayed on the room temperature indication (For max. minutes). Please wait until this PLEASE WAIT indication disappear then start the operation.

5 SPECIFICATIS Rating Conditions (JIS B8) Item Function Capacity Total input Service Ref. Power supply Input Running current Starting current External finish Heat exchanger Fan(drive))No. Fan motor output Airflow(Low-High) External static pressure Booster heater Operation control & Thermostat Noise level(low-high) Cond. drain connection O.. INOOR UNIT OUTOOR UNIT REFRIERANT PIPIN imensions Weight Service Ref. Power supply Input Running current Starting current External finish Refrigerant control Compressor Model Motor output Starter type Protection devices Heat exchanger Fan(drive))No. Fan motor output Airflow efrost method Crankcase heater Noise level imensions Weight Refrigerant Charge Pipe size O.. Connection method Between the indoor & outdoor unit W H W H Liquid as Service Ref. Btu/h W A A K/min <CFM> Pa(mmAq) db(a) kg,(lbs) A A K/min <CFM> W db(a) kg,(lbs) kg,(lbs) Indoor side Outdoor side Height difference Piping length Notes. Rating Conditions (JIS B8) : Indoor : :(80 o F)B. 9:( o F)WB Outdoor : :(9 o F)B. :( o F)WB : Indoor : 0:(8 o F)B. Outdoor : :( o F)B. :( o F)WB Refrigerant piping length (one way) : m(ft). Above data based on indicated voltage Indoor Unit phase 0V 0Hz Outdoor Unit phase 0V 0Hz 8,00, uaranteed operating range PCH-AK(H),00 (,900),00 (,00). (.) 0.0 (.0) 0.(.).0 (.98) Upper limit Lower limit Upper limit Lower limit,900, Indoor : B,.: WB : B,.: WB : B 0: B PCH-.AK(H) PCH-AK(H) PCH-.AK(H) Single phase. 0Hz. 0-0V Sirocco (direct)o <-9> Munsell 0.0Y 8.9 / 0.9 Plate fin coil Sirocco (direct)o <9-> 0 (direct blow) (.) (.) Remote controller & built-in - - (),000 (9-/8),0 (-9/) 80 (-/) 0 (8-/) (0) [8. ()] PUH-VKA.TH NH8VMT. 0.0 (,90) 0 (-/8) () Max. 0m Max. 0m Single phase. 0Hz. 0-0V. 9.9 Munsell.0Y.8/. Capillary tube Hermetic. 0.8 Line start Internal thermostat. High-pressure switch Plate fin coil Propeller (direct) () [ (9)] PUH-.VKA.TH NHVMT (,) Reverse cycle (-/) 9 + (-/8 add ) 80 (-/) 8 (0) R-. (.9).8 (.) 9. (/8).88 (/8) Flared Flared Max. 0m Max. 0m,00 (,00),00 (9,00). (.) 0. (.) 0. (9.0). (0.0). 9.8 Outdoor : B -: B : B,.: WB -8.: B, -9.: WB

6 Rating Conditions (JIS B8) Item Function Capacity Total input Service Ref. Power supply Input Running current Starting current External finish Heat exchanger Fan(drive))No. Fan motor output Airflow(Low-High) External static pressure Booster heater Operation control & Thermostat Noise level(low-high) Cond. drain connection O.. INOOR UNIT OUTOOR UNIT REFRIERANT PIPIN imensions Weight Service Ref. Power supply Input Running current Starting current External finish Refrigerant control Compressor Model Motor output Starter type Protection devices Heat exchanger Fan(drive))No. Fan motor output Airflow efrost method Crankcase heater Noise level imensions Weight Refrigerant Charge Pipe size O.. Connection method Between the indoor & outdoor unit W H W H Liquid as Service Ref. Btu/h W A A K/min (CFM) Pa(mmAq) db(a) kg,(lbs) A A K/min (CFM) W db(a) kg,(lbs) kg,(lbs) Indoor side Outdoor side Height difference Piping length Notes. Rating Conditions : Indoor :.B. :(80 o F) W.B. 9:( o F) Outdoor :.B. :(9 o F) W.B. :( o F) : Indoor :.B. 0:(8 o F) Outdoor :.B. :( o F) W.B. :( o F) Refrigerant piping length (one way) : m(ft). Above data based on indicated voltage Indoor Unit phase 0V 0Hz Outdoor Unit phase 0V 0Hz 8,00, uaranteed operating range PCH-AK PCH-AK Sirocco (direct)) (-9),00, Upper limit Lower limit Upper limit Lower limit,00,800. Single phase. 0Hz. 0V Munsell 0.0Y 8.9 / 0.9 Plate fin coil Indoor.B. : W.B..:.B. : W.B..:.B. :.B. 0: PCH-.AK PCH-.AK Sirocco (direct)) (9-) 0 (direct blow) Remote controller & built-in - - (),000 (9-/8),0 (-9/) 80 (-/) 0 (8-/) (0) PUH-AKA.TH-A NH8AMT. 0.0 (,90) 0 (-/8) () Max. 0m Max. 0m Single phase. 0Hz. 0V Munsell.0Y.8/. Capillary tube Hermetic Line start Internal thermostat. High-pressure switch Plate fin coil Propeller (direct)),00, () PUH-.AKA.TH-A NHAMT (,) Reverse cycle (-/) 9 + <-/8 add > 80 (-/) 8 (0) R-. (.0).8 (.) 9. (/8).88 (/8) Flared Flared Max. 0m Max. 0m.0 9. Outdoor.B. :.B. -:.B. : W.B..:.B.-8.: W.B.-9.:

7 Rating Conditions (JIS B8) Item Function Capacity Total input Service Ref. Power supply Input Running current External finish Heat exchanger Fan(drive))No. Fan motor output Airflow(Low-High) External static pressure Booster heater Operation control & Thermostat Noise level(low-high) Cond. drain connection O.. INOOR UNIT OUTOOR UNIT REFRIERANT PIPIN imensions Weight Service Ref. Power supply Input Running current Starting current External finish Refrigerant control Compressor Model Motor output Starter type Protection devices Heat exchanger Fan(drive))No. Fan motor output Airflow efrost method Crankcase heater Noise level imensions Weight Refrigerant Charge Pipe size O.. Connection method Between the indoor & outdoor unit W H W H Liquid as Service Ref. Btu/h W A K/min (CFM) Pa(mmAq) db(a) kg,(lbs) A A K/min (CFM) W db(a) kg,(lbs) kg,(lbs) Indoor side Outdoor side Height difference Piping length PCH-AK PCH-.AK w/w 8,00 /,000,00 /,00. /.9,00,0.8 w w/w,900 / 0,00,000 /,000.0 /.8,00 8,000.9 w PCH-AK PCH-.AK Single phase. 0Hz. 0V /.8.0 /.99 Sirocco (direct)o (-9) Munsell 0.0Y 8.9 / 0.9 Plate fin coil Sirocco (direct)o (9-) 0 (direct blow) Remote controller & built-in - - (),000 (9-/8),0 (-9/) 80 (-/) 0 (8-/) (0) PUH-NKA.TH NHJNBT. 0.0 (,90) 0 (-/8). () Max. 0m Max. 0m Single phase. 0Hz. 0V.. Munsell.0Y.8/. Capillary tube Hermetic.9 /..0 /. 8 Line start Internal thermostat. High-pressure switch Plate fin coil Propeller (direct) () PUH-.NKA.TH NHJ8NBT (,) Reverse cycle (-/) 9 + (-/8 add ) 80 (-/) () R-. (.9).8 (.) 9. (/8).88 (/8) Flared Flared Max. 0m Max. 0m Notes : w. Rating conditions (JIS 8) (INOOR) :.B. : W.B. 9: (OUTOOR) :.B. : w. Rating conditions (SSA 8) (INOOR) :.B. 9: W.B.9: :.B. : (OUTOOR) :.B. : :.B. :.B. :

8 Rating Conditions (JIS B8) Item Function Capacity Total input Service Ref. Power supply Input Running current Starting current External finish Heat exchanger Fan(drive))No. Fan motor output Airflow(Low-High) External static pressure Booster heater Operation control & Thermostat Noise level(low-high) Cond. drain connection O.. INOOR UNIT OUTOOR UNIT REFRIERANT PIPIN imensions Weight Service Ref. Power supply Input Running current Starting current External finish Refrigerant control Compressor Model Motor output Starter type Protection devices Heat exchanger Fan(drive))No. Fan motor output Airflow efrost method Crankcase heater Noise level imensions Weight Refrigerant Charge Pipe size O.. Connection method Between the indoor & outdoor unit W H W H Liquid as Service Ref. Btu/h W A A K/min (CFM) Pa(mmAq) db(a) kg,(lbs) A A K/min (CFM) W db(a) kg,(lbs) kg,(lbs) Indoor side Outdoor side Height difference Piping length Notes. Rating Conditions : Indoor :.B. :(80 o F) W.B. 9:( o F) Outdoor :.B. :(9 o F) W.B. :( o F) : Indoor :.B. 0:(8 o F) Outdoor :.B. :( o F) W.B. :( o F) Refrigerant piping length (one way) : m(ft). Above data based on indicated voltage Indoor Unit phase 0V 0Hz Outdoor Unit phase 0V 0Hz / phase V 0Hz 8,900, PCH-AK PCH-AK Single phase. 0Hz.0-0V 9,000 8, Munsell 0.0Y 8.9 / 0.9 Plate fin coil Sirocco (direct)o (9-) 0 (direct blow) Remote controller & built-in - (),0(-9/) 80 (-/) 0(8-/) () PUH-VKA.TH, PUH-VKA.TH-A/ PUH-YKA.TH, PUH-YKA.TH-A VKA...phase, 0Hz, 0-0V / YKA...phase, 0Hz, 00-V, wires..8 /. 8 / Munsell.0Y.8/. Capillary tube Hermetic NHVNHT/ NHYAT./. Line start VKA-A...Inner thermostat. High-pressure switch YKA-A...Anti-phase protector, Thermal relay, thermal switch, High-pressute switch. uaranteed operating range Upper limit Lower limit Upper limit Lower limit Plate fin coil Propeller (direct)o (,) Reverse cycle 8 80 (-/) 9 + (-/8 add ) 80 (-/) () R-. (.) 9. (/8).88 (/8) Flared Flared Max. 0m Max. 0m Indoor.B. : W.B..:.B. : W.B..:.B. :.B. 0:.9.89 /.8 8 / Outdoor.B. :.B. -:.B. : W.B..:.B.-8.: W.B.-9.:

9 Rating Conditions (JIS B8) Item Function Capacity Total input Service Ref. Power supply Input Running current Starting current External finish Heat exchanger Fan(drive))No. Fan motor output Airflow(Low-High) External static pressure Booster heater Operation control & Thermostat Noise level(low-high) Cond. drain connection O.. INOOR UNIT OUTOOR UNIT REFRIERANT PIPIN imensions Weight Service Ref. Power supply Input Running current Starting current External finish Refrigerant control Compressor Model Motor output Starter type Protection devices Heat exchanger Fan(drive))No. Fan motor output Airflow efrost method Crankcase heater Noise level imensions Weight Refrigerant Charge Pipe size O.. Connection method Between the indoor & outdoor unit W H W H Liquid as Service Ref. Btu/h W A A K/min <CFM> Pa(mmAq) db(a) kg,(lbs) A A K/min <CFM> W db(a) kg,(lbs) kg,(lbs) Indoor side Outdoor side Height difference Piping length Notes. Rating Conditions (JIS B8) : Indoor : :(80 o F)B. 9:( o F)WB Outdoor : :(9 o F)B. :( o F)WB : Indoor : 0:(8 o F) Outdoor : :( o F)B. :( o F)WB. Refrigerant piping length (one way) : m(ft). Above data based on indicated voltage Indoor Unit phase 0V 0Hz Outdoor Unit phase 0V 0Hz / phase V 0Hz. uaranteed operating range 9,00, PCH-AK(H) 9,000 (,00) 8,00 (0,00).0 (.) 0. (.) 0. (9.0). (0.0) Upper limit Lower limit Upper limit Lower limit,00 0, Indoor : B,.: WB : B,.: WB : B 0: B PCH-AK(H) PCH-AK(H) PCH-AK(H) Single phase. 0Hz. 0-0V <9-> Munsell 0.0Y 8.9 / 0.9 Plate fin coil Sirocco (direct) O <0-88> 0 (direct blow) (.) (.) Remote controller & built-in (),0 ( -9/ ) 80 (-/) 0 (8-/) 0 (0-/8) () [ (9)] PUH-VKA.TH/ PUH-YKA.TH Munsell.0Y.8/. Capillary tube Hermetic NHVNHT/ NHYAT. /. Line start Propeller (direct) O (,) 8 80 (-/) (). (.) 9. (/8).88 (/8) Max. 0m Max. 0m,00 (,900) 0,0 (,0).(.0) 0. (.8) 0.0 (.9).8 (.) (8) [9. (8)] PUH-YKSA.TH, PUH-YKSA.TH-A VKA...phase, 0Hz, 0-0V / YK(S)A...phase, 0-80Hz, V, wires..8 /. 8 /.9.89 /.8 8 / Reverse cycle 80 <-/> 9 + <-/8 add > R- NHYAT. VKA...Inner thermostat. High-pressure switch YKA...Anti-phase protector, Thermal relay, Thermal switch, High-pressute switch Plate fin coil Flared Flared.0. 0 Propeller (direct) O (,0) 8,8 (9-/) 9 (0). (9.) 9. (/8) 9.0 (/).9. 0 Outdoor : B -: B : B,.: WB -8.: B, -9.: WB

10 Rating Conditions (JIS B8) Item Function Capacity Total input INOOR UNIT OUTOOR UNIT REFRIERANT PIPIN Service Ref. Power supply Input Running current External finish Heat exchanger Fan(drive))No. Fan motor output Airflow(Low-High) External static pressure Booster heater Operation control & Thermostat Noise level(low-high) Cond. drain connection O.. imensions Weight Service Ref. Power supply Input Running current Starting current External finish Refrigerant control Compressor Model Motor output Starter type Protection devices Heat exchanger Fan(drive))No. Fan motor output Airflow efrost method Crankcase heater Noise level imensions Weight Refrigerant Charge Pipe size O.. Connection method Between the indoor & outdoor unit W H W H Liquid as Service Ref. Btu/h W A K/min (CFM) Pa(mmAq) db(a) kg,(lbs) A A K/min (CFM) W db(a) kg,(lbs) kg,(lbs) Indoor side Outdoor side Height difference Piping length PCH-AK w/w,900 /,00,00 /,00. /.8 0,900 9,00.8 w PCH-AK w/w,900 /,00,00 / 9,80. /.,00,0. w /..9 / PCH-AK (9-) Single phase. 0Hz. 0V Reverse cycle Munsell 0.0Y 8.9 / 0.9 Plate fin coil Sirocco (direct) O PCH-AK (0-88) 0 (direct blow) Remote controller & built-in (),0 ( -9/ ) 80 (-/) 0 (8-/) 0 (0-/8) () (8) PUH-NKA.TH PUH-TKSA.TH Single, 0Hz, 0V 8 80 (-/) 8 (). (.) 9. (/8).88 (/8) Munsell.0Y.8/. Capillary tube Hermetic NHJNAT. Line start Inner thermostat, HP. switch Plate fin coil Propeller (direct) O (,) Notes: w. Rating conditions (JIS 8) (INOOR) :.B. : W.B. 9: (OUTOOR) :.B. : w. Rating conditions (SSA 8) (INOOR) :.B. 9: W.B. 9: :.B. : (OUTOOR) :.B. : :.B. : W.B. : w. Thermal relay, Thermal switch, Reversed phase protector, HP switch (-/) 9 + (-/8 add ) R- Flared Flared Max. 0m Max. 0m. /.0.8 /. 9, 0Hz, 0V NHJTKAT. w Propeller (direct) O (,0) 8,8 (9-/). (0.). (0.) 9. (/8) 9.0 (/)

11 Rating Conditions (JIS B8) Item Function Capacity Total input Service Ref. Power supply Input Running current Starting current External finish Heat exchanger Fan(drive))No. Fan motor output Airflow(Low-High) External static pressure Booster heater Operation control & Thermostat Noise level(low-high) Cond. drain connection O.. INOOR UNIT OUTOOR UNIT REFRIERANT PIPIN imensions Weight Service Ref. Power supply Input Running current Starting current External finish Refrigerant control Compressor Model Motor output Starter type Protection devices Heat exchanger Fan(drive))No. Fan motor output Airflow efrost method Crankcase heater Noise level imensions Weight Refrigerant Charge Pipe size O.. Connection method Between the indoor & outdoor unit W H W H Liquid as Service Ref. Btu/h W A A K/min <CFM> Pa(mmAq) db(a) kg,(lbs) A A K/min <CFM> W db(a) kg,(lbs) kg,(lbs) Indoor side Outdoor side Height difference Piping length Notes. Rating Conditions (JIS B8) : Indoor : :(80 o F)B. 9:( o F)WB Outdoor : :(9 o F)B. :( o F)WB : Indoor : 0:(8 o F)B. Outdoor : :( o F)B. :( o F)WB. Refrigerant piping length (one way) : m(ft). Above data based on indicated voltage Indoor Unit phase 0V 0Hz Outdoor Unit phase V 0Hz,00, uaranteed operating range PCH-AK(H),00 (,00),900 (,900).0 (.0) 0. (.).0 (.).0 (.0) Upper limit Lower limit Upper limit Lower limit 9,00, Indoor : B,.: WB : B,.: WB : B 0: B PCH-AK(H) PCH-AK(H) PCH-AK(H) Single phase. 0Hz. 0-0V Munsell 0.0Y 8.9 / 0.9 Plate fin coil Sirocco (direct) O 0. - <9-,00> 0 (direct blow) (.0) Remote controller & built-in - -8 (),0 (-/) 80 (-/) 0 (0-/8) (9) [ (0)] PUH-YKSA.TH, PUH-YKSA.TH-A..89 ZRKC-TF (,0) phases. 0Hz. 80-V ( wires)..8 Munsell.0Y.8/. Capillary tube Hermetic,00 (,00),000 (8,000).8 (.8) 0. (.).0 (.).0 (.0) (99) [8 (0)] PUH-YKSA.TH, PUH-YKSA.TH-A.. ZR8KC-TF.0 Line start Anti-phase protector, Internal thermostat, Thermal switch, High-pressure switch Plate fin coil Propeller (direct) O (,0) Reverse cycle 8 90 (8-/) + (-9/ add ),8 (9-/) () (8) R-. (.9).0 (.0) 9. (/8) 9.0 (/) Flared Flared Max. 0m Max. 0m.8.0 Outdoor : B -: B : B,.: WB -8.: B, -9.: WB

12 Rating Conditions (SSA 8) Item Function Capacity Total input Service Ref. Power supply Input Running current Starting current External finish Heat exchanger Fan(drive))No. Fan motor output Airflow(Low-High) External static pressure Booster heater Operation control & Thermostat Noise level(low-high) Cond. drain connection O.. INOOR UNIT OUTOOR UNIT REFRIERANT PIPIN imensions Weight Service Ref. Power supply Input Running current Starting current External finish Refrigerant control Compressor Model Motor output Starter type Protection devices Heat exchanger Fan(drive))No. Fan motor output Airflow efrost method Crankcase heater Noise level imensions Weight Refrigerant Charge Pipe size O.. Connection method Between the indoor & outdoor unit W H W H Liquid as Service Ref. Btu/h W A A K/min <CFM> Pa(mmAq) db(a) kg,(lbs) A A K/min <CFM> W db(a) kg,(lbs) kg,(lbs) Indoor side Outdoor side Height difference Piping length,00, PCH-AK PCH-AK,00, ,00,00.8 Single phase. 0Hz. 0V 0..0 PCH-AK PCH-AK Munsell 0.0Y 8.9 / 0.9 Plate fin coil Sirocco (direct) O 0. - <9-,00> 0 (direct blow) Remote controller & built-in - -8 (),0 (-/) 80 (-/) 0 (0-/8) (9) PUH-TKSA.TH ZRKC-TF (,0) phases. 0Hz,0V..8 Munsell.0Y.8/. Capillary tube Hermetic (99) PUH-TKSA.TH ZR8KC-TF (,0) Reverse cycle 8 90 (8-/) + (-9/ add ),8 (9-/) () (8) R-. (.9).0 (.0) 9. (/8) 9.0 (/) Flared Flared Max. 0m Max. 0m 9,00, Line start Anti-phase protector, Internal thermostat, Thermal switch, High-pressure switch Plate fin coil Propeller (direct) O Notes: w. Rating conditions (SSA 8) : Indoor :.B. 9: W.B. 9: Outdoor :.B. : :Indoor :.B. : Outdoor :.B. :( F) W.B. :( F) Refrigerant piping length(one way):m(ft) w. Above data based on indicated voltage Indoor Unit phase 0V 0Hz Outdoor Unit phase 0V 0Hz

13 ATA -. PERFORMANCE ATA ) COOLIN CAPACITY Service Ref CA Outdoor intake air B C Refrigerant piping length (one way) PCH-AK(H) PCH-.AK(H) PCH-AK(H) PCH-AK(H) PCH-AK(H) PCH-AK(H) Service Ref. m m m m m m m m m m Indoor Intake air WB C P.C CA P.C. CA P.C. CA P.C. CA P.C. CA P.C. PCH-AK/ PUH-AKA.TH-A PCH-.AK/ PUH-.AKA.TH-A PCH-AK/ PUH-VKA.TH, PUH-VKA.TH-A, PUH-YKA.TH, PUH-YKA.TH-A PCH-AK, PCH-AKH/ PUH-YKSA.TH PUH-YKSA.TH-A PCH-AK, PCH-AKH/ PUH-YKSA.TH PUH-YKSA.TH-A PCH-AK, PCH-AKH/ PUH-YKSA.TH PUH-YKSA.TH-A PCH-AK, PCH-AKH/ PUH-VKA.TH PCH-.AK, PCH-.AKH/ PUH-.VKA.TH PCH-AKH/ PUH-VKA.TH, PUH-YKA.TH Notes CA : Capacity (W) P.C. : Power consumption () capacity correction factors 0Hz

14 ) HEATIN CAPACITY Service Ref CA Outdoor intake air WB C Refrigerant piping length (one way) PCH-AK(H) PCH-.AK(H) PCH-AK(H) PCH-AK(H) PCH-AK(H) PCH-AK(H) Service Ref. m m m m m m m m m m Indoor Intake air B C P.C CA P.C. CA P.C. CA P.C. CA P.C. CA P.C PCH-AK, PCH-AKH/ PUH-VKA.TH PCH-AK/ PUH-AKA.TH-A PCH-.AK, PCH-.AKH/ PUH-.VKA.TH PCH-.AK/ PUH-.AKA.TH-A PCH-AK, PCH-AKH/ PUH-VKA.TH, PUH-VKA.TH-A, PUH-YKA.TH, PUH-YKA.TH-A PCH-AK, PCH-AKH/ PUH-YKSA.TH PUH-YKSA.TH-A PCH-AK, PCH-AKH/ PUH-YKSA.TH PUH-YKSA.TH-A PCH-AK, PCH-AKH/ PUH-YKSA.TH PUH-YKSA.TH-A Notes CA : Capacity (W) P.C. : Power consumption () capacity correction factors

15 -. PERFORMANCE ATA ) COOLIN CAPACITY Service Ref. PCH-AK/ PUH-NKA.TH PCH-.AK/ PUH-.NKA.TH PCH-AK/ PUH-NKA.TH PCH-AK/ PUH-TKSA.TH Indoor Intake air W.B.( C) Notes CA : Capacity (W) P.C. : Power consumption () CA Hz Outdoor intake air.b.( C) P.C CA P.C. CA P.C. CA P.C. CA P.C. CA P.C capacity correction factors Service Ref. PCH-AK PCH-.AK PCH-AK PCH-AK PCH-AK PCH-AK m m m m Refrigerant piping length (one way) m m m m m m

16 ) HEATIN CAPACITY Service Ref. PCH-AK/ PUH-NKA.TH PCH-.AK/ PUH-.NKA.TH PCH-AK/ PUH-NKA.TH PCH-AK/ PUH-TKSA.TH Indoor Intake air.b.( C) Notes CA : Capacity (W) P.C. : Power consumption () CA Outdoor intake air W.B.( C) P.C CA P.C. CA P.C. CA P.C. CA P.C. CA P.C capacity correction factors Service Ref. PCH-AK PCH-.AK PCH-AK PCH-AK PCH-AK PCH-AK m m m m Refrigerant piping length (one way) m m m m m m

17 -. ELECTRICAL ATA Rating Conditions (JIS B8) Indoor 0V 0Hz phase Outdoor 0V 0Hz phase / 80V 0Hz phase Indoor unit MOEL Outdoor unit Mode Capacity (W) Total Input () Input () Current (A) Starting current (A) Input () Current (A) Starting current (A) Indoor Outdoor PCH-AKH PCH-.AKH PCH-AKH PCH-AKH PCH-AKH PCH-AKH PUH-VKA PUH-.VKA PUH-VKA/PUH-YKA PUH-YKSA PUH-YKSA PUH-YKSA, ,00 [,80]. [.0] , ,000 [8,0]. [.0] , ,00 [0,0].0 [.9] , ,0 [,0].0 [.] , ,00 [,0]. [.8] , ,800 [,0]. [.8] /..8/ / / Indoor 0V 0Hz phase Outdoor 0V 0Hz phase / 00V 0Hz phase MOEL Indoor unit PCH-AKH PCH-.AKH PCH-AKH PCH-AKH PCH-AKH PCH-AKH Outdoor unit PUH-VKA PUH-.VKA PUH-VKA/PUH-YKA PUH-YKSA PUH-YKSA PUH-YKSA Mode Capacity (W),0,0 [,0],90 00 [8,980],0 8,0 [0,80] 9,90 0,00 [,880],00,800 [,0],0,900 [,0] Total Input ().. [.].. [.]..0 [.98].. [.8].. [.].9.9 [.] Input () Current (A) Starting current (A) Input () Current (A) /.. / Starting current (A) / / 9 9 Indoor Outdoor Indoor 0V 0Hz phase Outdoor 0V 0Hz phase / V 0Hz phase Indoor unit MOEL Outdoor unit Mode Capacity (W) Total Input () Input () Current (A) Starting current (A) Input () Current (A) Starting current (A) Indoor Outdoor Indoor unit MOEL Outdoor unit Mode Capacity (W) Total Input () Input () Current (A) Starting current (A) Input () Current (A) Starting current (A) Indoor Outdoor PCH-AKH Indoor 0V 0Hz phase Outdoor 0V 0Hz phase PCH-AK PUH-AKA PCH-.AKH PUH-VKA PUH-.VKA PUH-VKA/PUH-YKA PUH-YKSA PUH-YKSA PUH-YKSA,00,00 8,00 0,0,900,000,00 [,00],000 [9,00],00 [0,00] 0,000 [,0],00 [,900],00 [8,000].0. [.].9. [.].8.0 [.].. [.0]..0 [.0].9.8 [.8] /..89 / / 8 / 0 0, , PCH-.AK PUH-.AKA, , PCH-AKH PCH-AKH PCH-AKH PCH-AKH

18 Rating Conditions (JIS B8) Indoor 0V 0Hz phase Outdoor 0V 0Hz phase / 80V 0Hz phase Indoor unit MOEL Outdoor unit Mode Capacity (W) Total Input () Input () Current (A) Starting current (A) Input () Current (A) Starting current (A) Indoor Outdoor PCH-AK PCH-.AK PCH-AK PCH-AK PCH-AK PCH-AK PUH-VKA PUH-.VKA PUH-VKA/PUH-YKA PUH-YKSA PUH-YKSA PUH-YKSA, , , , , , , , , , , , /..8/ / / Indoor 0V 0Hz phase Outdoor 0V 0Hz phase / 00V 0Hz phase Indoor unit MOEL Outdoor unit Mode Capacity (W) Total Input () Input () Current (A) Starting current (A) Input () Current (A) Starting current (A) Indoor Outdoor PCH-AK PCH-.AK PCH-AK PCH-AK PCH-AK PCH-AK PUH-VKA PUH-.VKA PUH-VKA/PUH-YKA PUH-YKSA PUH-YKSA PUH-YKSA, , , , , , , , , , , /.. / / / 9 9 Indoor 0V 0Hz phase Outdoor 0V 0Hz phase / V 0Hz phase Indoor unit MOEL Outdoor unit Mode Capacity (W) Total Input () Input () Current (A) Starting current (A) Input () Current (A) Starting current (A) Indoor Outdoor PCH-AK PCH-.AK PCH-AK PCH-AK PCH-AK PCH-AK PUH-VKA PUH-.VKA PUH-VKA/PUH-YKA PUH-YKSA PUH-YKSA PUH-YKSA, , , , , , , , , , , , /..89 / / 8 / 0 0 8

19 Indoor 0V 0Hz phase Outdoor 0V 0Hz phase/phases Rating conditions () Indoor :.B. : W.B. 9: Outdoor :.B. : Indoor unit MOEL Outdoor unit Mode Capacity (W) Total Input () Indoor unit Outdoor unit Input () Current (A) Starting current (A) Input () Current (A) Starting current (A) PCH-AK PUH-NKA, PCH-.AK PUH-.NKA, Rating condition () Indoor :.B. 9: W.B.9: Outdoor :.B. : Rating condition () Indoor :.B. : Outdoor :.B. : W.B. : } (SSA8,8) Indoor unit MOEL Outdoor unit Mode Capacity (W) Total Input () Indoor unit Outdoor unit Input () Current (A) Input () Current (A) Starting current (A), PCH-AK PUH-NKA, PCH-.AK PUH-.NKA, , Rating conditions () Indoor :.B. : W.B. 9: Outdoor :.B : Indoor unit MOEL Outdoor unit Mode Capacity (W) Total Input () Indoor unit Outdoor unit Indoor unit Outdoor unit Input () Current (A) Starting current (A) Input () Current (A) Starting current (A) MOEL Indoor unit Outdoor unit Mode Capacity (W) Total Input () Input () Current (A) Input () Current (A) Starting current (A) PCH-AK PUH-NKA, , PCH-AK PUH-NKA 9, PCH-AK PUH-TKSA, Rating condition () Indoor :.B. 9: W.B. 9: Outdoor :.B. : W.B. : Rating condition () Indoor :.B. : Outdoor :.B. : W.B. : } (SSA8,8) 9, PCH-AK PUH-TKSA, PCH-AK PUH-TKSA, , PCH-AK PUH-TKSA, ,

20 -. STANAR OPERATI ATA Rating Conditions (JIS B8) Service Ref. Mode Capacity Input Indoor unit Service Ref. Phase, Hz Volts Amperes Electrical circuit Total Refrigerant circuit Indoor side Outdoor side Outdoor unit Service Ref. Phase, Hz Volts Amperes ischarge pressure Suction pressure ischarge temperature Condensing temperature Suction temperature Ref. pipe length Intake air temperature ischarge air temperature Intake air temperature SHF BF W KW V A V A Mpa (Of/F ) Mpa (Of/F ) C C C m B C WB C B C B C WB C PCH-AKH PCH-.AKH PCH-AKH PCH-AKH PCH-AKH PCH-AKH,00,00 8,00 0,0,900,000,00 [,00],000 [9,00],00 [0,00] 0,000 [,0],00 [,900],00 [8,000] PCH-AKH, PUH-VKA.TH PUH-.VKA.TH, (9.) (9.) (.8) [.] (.) PCH-.AKH, [.] PCH-AKH, PUH-VKA.TH PUH-YKA.TH, 0 /, / /..89/.8.0 (0.9). (.).0 (0.8).9 (9.8) (.) (.8) (.9) [.] (.) PCH-AKH, PUH-YKSA.TH PUH-YKSA.TH PUH-YKSA.TH..8 (8.) 0.0 (.) , 0 [.0].. (.) 0.9 (.98) PCH-AKH, , (9.) (8.) (.90) [.0] (.) PCH-AKH, , (0.) (8.) (.9) [.8] (.88) The unit of pressure has been changed to Mpa on the international system of unit (SI unit system). The converted score against the traditional unit system can be gotten according to the formula below. (Mpa )=0.(Of/F ) 0

21 Service Ref. Mode Capacity Input Indoor unit Service Ref. Phase, Hz Volts Amperes Electrical circuit Total Refrigerant circuit Indoor side Outdoor side Outdoor unit Servise Ref. Phase, Hz Volts Amperes ischarge pressure Suction pressure ischarge temperature Condensing temperature Suction temperature Ref. pipe length Intake air temperature ischarge air temperature Intake air temperature SHF BF.B. W.B..B..B. W.B. W KW V A V A MPa (kgf/f) MPa (kgf/f) C C C m C C C C C PCH-AK,00.8 PCH-AK, (9.) 0. (.8) ,0.9 PUH-AKA.TH-A PUH-.AKA.TH-A, (9.) 0. (.8) PCH-.AK,800. PCH-.AK, (0.) 0. (.) , 0 0, (.9) 0.8 (.9) PCH-AK,00.8 PCH-AK, /..0 (0.8) 0. (.) ,00.0 PUH-VKA.TH-A PUH-YKA.TH-A /, 0 0 /.89/.8.9 (9.8) 0. (.) PCH-AK 0,000. PCH-AK, (8.) 0.0 (.) ,0. PUH-YKSA.TH-A PUH-YKSA.TH-A PUH-YKSA.TH-A, 0.. (.) 0.9 (.0) The unit of pressure has been changed to MPa based on the international SI system. The conversion factor is : (MPa)=0.(kgf/F) PCH-AK,00. PCH-AK, (9.) 0.8 (.9) , 0, (8.) 0. (.8) PCH-AK,00.9 PCH-AK, (0.) 0. (.) , 0, (8.) 0.8 (.9)

22 Service Ref. PCH-AK PCH-.AK PCH-AK PCH-AK Mode Capacity Input Electrical circuit Total Refrigerant circuit Indoor side Outdoor side Indoor unit service Ref. Phase, Hz Volts Amperes Outdoor unit service Ref. Phase, Hz Volts Amperes ischarge pressure Suction pressure ischarge temperature Condensing temperature Suction temperature Ref. pipe length.b. Intake air temperature W.B. ischarge air temperature.b..b. Intake air temperature W.B. W KW V A V A MPa (Of/F) MPa (Of/F) : : : m : : : : :,00.9, PUH-NKA.TH, (.) (0.) (.0) (.) ,0.8 PCH-AK 9 -..,000.8 PCH-.AK, PUH-.NKA.TH, (.) (9.9) (.) (.8) , ,00.8 PCH-AK, PUH-NKA.TH, (.) (.) (.) (.) , ,80., PUH-TKSA.TH, (.0) (0.) (.8) (.) ,0. PCH-AK Service Ref. Mode Capacity Input Indoor unit service Ref. Phase, Hz Volts Amperes Outdoor unit service Ref. Phase, Hz Volts Amperes Electrical circuit Total Refrigerant circuit Indoor side Outdoor side ischarge pressure Suction pressure ischarge temperature Condensing temperature Suction temperature Ref. pipe length.b. Intake air temperature W.B. ischarge air temperature.b. Intake air temperature.b. W.B. W KW V A V A MPa (Of/F) MPa (Of/F) : : : m : : : : : PCH-AK,000. PCH-AK, PUH-TKSA.TH, (9.) (.8) (.88) (.) , PCH-AK,00.8 PCH-AK, PUH-TKSA.TH, (0.) (.) (.) (.) , The unit of pressure has been changed to MPa based on the international SI system. The conversion factor is : (MPa)=0.(kgf/F)

23 OUTLINES AN IMENSIS PCH-AK PCH-AKH rainage pipe connection (mm I..) Refrigerant-pipe connection (liquid pipe side/flared connection) rainage pipe connection (for the left arrangement) Knock out hole for upper pipe arrangement Knock out hole for left drain-piping arrangement Knock out hole for left drain pipe arrangement Refrigerant-pipe connection (gas pipe side/flared connection) 8 Knock out hole for wiring arrangement NOTES:. Use M0 or W/8 screws for anchor bolt.. Please be sure when installing the drain-up machine (option parts). refrigerant pipe will be only upper drain pipe arrangement. [Front view] Electrical box Celling ~ 9 (suspension bolt pitch) 8 98 When electrical box is pulled down 98 0 Electrical box (/8F) liquid 0 (/8F) gas (rainage) Air outlet Air intake 98 Unit : mm

24 PCH-.AK PCH-.AKH PCH-AK PCH-AKH Unit : mm rainage pipe connection (mm I..) Refrigerant-pipe connection (liquid pipe side/flared connection) rainage pipe connection (for the left arrangement) Knock out hole for upper pipe arrangement Knock out hole for left drain-piping arrangement Knock out hole for left drain pipe arrangement Refrigerant-pipe connection (gas pipe side/flared connection) 8 Knock out hole for wiring arrangement NOTES:. Use M0 or W/8 screws for anchor bolt.. Please be sure when installing the drain-up machine (option parts). refrigerant pipe will be only upper drain pipe arrangement When electrical box is pulled down Electrical box [ Front view ] 8 Celling 0 (suspension bolt pitch) Air outlet (/8F liquid) (/8F gas) (rainage) 80 ~ Electrical box Air intake 8

25 PCH-AK PCH-AKH Unit : mm rainage pipe connection (mm I..) Refrigerant-pipe connection (liquid pipe side/flared connection) rainage pipe connection (for the left arrangement) Knock out hole for upper pipe arrangement Knock out hole for left drain-piping arrangement Knock out hole for left drain pipe arrangement NOTES: Refrigerant-pipe connection (gas pipe side/flared connection) 8 Knock out hole for wiring arrangement. Use M0 or W/8 screws for anchor bolt.. Please be sure when installing the drain-up machine (option parts). refrigerant pipe will be only upper drain pipe arrangement. 0 (suspension bolt pitch) 0 Air outlet Electrical box [ Front view ] 8 Celling When electrical box is pulled down 0 ~ Electrical box (/8F liquid) (/F-gas) (rainage) Air intake 8

26 PCH-AK PCH-AK PCH-AKH PCH-AKH (/8F liquid) (/F gas) (rainage) Unit : mm rainage pipe connection (mm I..) Refrigerant-pipe connection (liquid pipe side/flared connection) rainage pipe connection (for the left arrangement) Knock out hole for upper pipe arrangement Knock out hole for left drain-piping arrangement Knock out hole for left drain pipe arrangement Refrigerant-pipe connection (gas pipe side/flared connection) 8 Knock out hole for wiring arrangement NOTES:. Use M0 or W/8 screws for anchor bolt.. Please be sure when installing the drain-up machine (option parts). refrigerant pipe will be only upper drain pipe arrangement. (suspension bolt pitch) 0 Air outlet Electrical box [ Front view ] 8 Celling 0 8 Air intake 8 98 ~ When electrical box is pulled down Electrical box 9

27 WIRE REMOTE CTROLLER Unit : mm 0 0 9

28 WIRIN IARAM PCH-AK(H) PCH-.AK(H) PCH-AK(H) PCH-AK(H) PCH-AK(H) PCH-AK(H) SYMBOL NAME P.B INOOR POWER BOAR I.B INOOR CTROLLER BOAR FUSE FUSE (T.AL0V) ZNR VARISTOR CNL CNECTOR<LOSSNAY> CN CNECTOR<REMOTE SWITCH> CN CNECTOR<HA TERMINAL-A> CN CNECTOR<CENTRALLY CTROL> SW SWITCH <MOEL SELECTI>*See Table. SW SWITCH <CAPACITY COE>*See Table. SW SWITCH<SYSTEM SELECTI>*See Table. SW SWE SWITCH<EMERENCY OPERATI> CNECTOR<EMERENCY OPERATI> X RELAY<RAIN PUMP> X RELAY<FAN MOTOR> BCR FAN CTROL ELEMENT LE POWER SUPPLY<I.B> LE POWER SUPPLY<R.B> SYMBOL NAME C CAPACITOR<FAN MOTOR> MF FAN MOTOR MV VANE MOTOR P RAIN-UP MACHINE (OPTIAL) TB TERMINAL BLOCK (POWER SUPPLY) TB TERMINAL BLOCK<INOOR/OUTOOR CNECTIN LINE> TB TERMINAL BLOCK<REMOTE CTROLLER TRANSMISSI LINE > TH ROOM TEMP.THERMISTOR <0:/k", :/.k" ETECT> TH PIPE TEMP.THERMISTOR/LIQUI <0:/k", :/.k" ETECT> SYMBOL W.B RU BZ LE LE SW SW R.B TB HEATER FS, H H 88H NAME WIRELESS REMOTE CTROLLER BOAR<OPTI> RECEIVIN UNIT BUZZER LE<RUN INICATOR > LE<HOT AJUST> SWITCH<HEATIN /OFF> SWITCH<COOLIN /OFF> WIRE REMOTE CTROLLER BOAR TERMINAL BLOCK<REMOTE CTROLLER TRANSMISSI LINE > THERMAL FUSE <98: 0A: AKH/ : A: AKH/ 0: A:.,,,AKH> HEATER HEATER THERMAL SWITCH HEATER CTACTOR Refer to tables,, Please set the voltage using the remote controller. For the setting method, please refer to the indoor unit Installation Manual OFF SWE When installing drain-up machine (Optional part). SW RE WHT WHT BLK SW MF X SW WHT RE (.SENSOR) (PUMP) CN CN RN (VANE) CNV SW OFF WHT (WIRERESS) CN90 BLU (REMOC) CN *When installing optional WHT (.SENSOR) drain-up machine, disconnect TB CN the CN jumper connector MV TH TH and replace it with the drain sensor (S). (OPTI) I.B WHT RE BLU ORN RE (FAN) (.HEATER) (.U.M) (POWER) (POWER FAN CNC CNP CN BOAR) X FUSE CNK BCR WHT X (POWER ZNR BOAR) CN P X RE BLU CN CNL RE WHT LE LE CN CN BLK RE (INTAKE) (INOOR/OUTOOR COMUNICATI) CN0 WHT (PIPE) CN CN0 YLW ORN BRN BLU BLU BLK WHT P.B CNSK (RE) C.V CNS (WHT) TRANSMISSI WIRES CV TB L N RN/YLW TB I.B H YLW YLW POWER SUPPLY [Servicing] ~(PHASE) Fasten terminal of the terminal board"tb"equips lock system. 0-0V 0Hz 0V 0Hz To remove the fastened terminal, pull it while pressing the protruding portion (locking lever) of the terminal. The fastened terminal protruding portion should face upward. TO OUTOOR UNIT YLW (HEATER) CN RY 88H FS RE H RE FS RE WHT R.B TB BZ RU RECEIVER 9 88H TB RE RE L BLU N RN/YLW CNB W.B (OPTI) LE LE SW SW PCH-~AKH models only POWER SUPPLY ~(PHASE) 0-0V 0Hz 0V 0Hz S [Self-diagnosis]. For details on how to operate self-diagnosis with the wireless remote control, refer to the technical manuals etc.. For the wired remote control : When you quickly press twice the CHECK switch on the remote control, the unit begins self-diagnosis, and Check Codes generated in the past appear on the display. For Check Codes and Symptoms refer to the table. Check code Symptom P Abnormality of room temperature thermistor.(th). P Abnormality of pipe temperature thermistor / Liquid.(TH). P Abnormality of drain sensor(s). P Malfunction of drain-up machine. P Freezing / overheating protection is working. P8 Abnormality in outdoor unit. Refer to outdoor unit wiring diagram. E0 E Abnormality of the signal transmission between remote controller and indoor unit. Fb Abnormality of indoor controller board. No trouble generated in the past. FFFF No corresponding unit. Table SW OFF Table MOELS PCH-AK(H) PCH-.AK(H) PCH-AK(H) Table SW MOELS PCH-AK(H) OFF OFF OFF SW 8 PCH-AK(H) PCH-AK(H) OFF SW OFF OFF OFF NOTES:. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring for servicing.. Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (,, ).. Symbols used in wiring diagram above are, : Connector, : Terminal (block). [Emergency operation procedure].when the indoor unit microcomputer has failed, but all other components work properly, if you set the switch(swe,sw)on the indoor control board, the indoor unit will begin Emergency Operation..When you activate emergency operation of the cooling or heating, you have to set the switch(swe)and switch(sw)on indoor controller. SWE: Indoor fan is running high speed. rain-up machine(optional)is working. SW-: Emergency operation of cooling mode. SW-,: Emergency operation of heating mode..before you activate emergency operation, check the following points: Emergency operation cannot be activated when: The outdoor unit malfunctions. The indoor fan malfunctions. Emergency operation becomes continuous only by switching the power source on / off. / OFF on the remote control or temperature control etc. does not function. Avoid operating for a long time when the outdoor unit begins defrosting while emergency operation of the heating is activated, because it will start to blow cold air. Emergency cooling should be limited to 0 hours maximum (The indoor unit heat exchanger may freeze). After emergency operation has been deactivated, set the switches etc. to their original positions. Movement of the vanes does not work in emergency operation, therefore you have to slowly set them manually to the appropriate position. 8

29 REFRIERANT SYSTEM IARAM PCH-AK(H) / PUH-VKA.TH, PUH-AKA.TH-A, PUH-NKA.TH PCH-.AK(H) / PUH-.VKA.TH, PUH-.AKA.TH-A, PUH-.NKA.TH PCH-AK(H) / PUH-VKA.TH, PUH-VKA.TH-A, PUH-NKA.TH PUH-YKA.TH, PUH-YKA.TH-A Unit : mm Indoor unit Indoor heat exchanger Indoor coil thermistor TH istributor with strainer Restrictor valve Strainer Refrigerant pipe (option).88mm( /8") (with heat insulator) Flexible tube Capillary tube PCH-(O... I...-R0) PCH-.(O... I...8-R0) PCH-(O...0 I...0-R80) Flared connection Refrigerant flow in cooling Refrigerant flow in heating Oil separator -way valve Ball valve Strainer Service port Accumulator Refrigerant pipe Ball valve (option) (with service port) 9.mm( /8") (with heat insulator) Service port Compressor High pressure control switch Outdoor unit Outdoor heat exchanger Bypass valve Restrictor valve Strainer <R.V.coil> OFF Outdoor coil thermistor (RT) Capillary tube PUH-(O...0 I...0-R0) PUH-.(O...0 I...-R0) PUH-(O...0 I...-R00) PCH-AK(H) / PUH-YKSA.TH, PUH-YKSA.TH-A, PUH-TKSA.TH Indoor unit Indoor heat exchanger Indoor coil thermistor TH Restrictor valve Strainer Refrigerant pipe (option) -way valve 9.0mm( /) Ball valve (with heat insulator) Strainer Flexible tube Flared connection Service port Oil separator Accumulator Service port Compressor High pressure control switch Outdoor unit Outdoor heat exchanger Bypass valve Outdoor coil thermistor (RT) Restrictor valve Capillary tube (O... I...0-R80) istributor with strainer Capillary tube (O...0 I...0-R0) Refrigerant pipe Ball valve (option) (with service port) 9.mm( /8") (with heat insulator) Strainer 9

30 PCH-AK(H) / PCH-AK(H) / PUH-YKSA.TH, PUH-YKSA.TH-A PUH-YKSA.TH, PUH-YKSA.TH-A Unit : mm Indoor unit Indoor heat exchanger Indoor coil thermistor TH Restrictor valve Strainer Refrigerant pipe (option) 9.0mm( /") Ball valve (with heat insulator) Strainer Flexible tube Flared connection Service port -way valve Accumulator Oil separator High pressure control switch Service port Compressor Outdoor unit Outdoor heat exchanger Bypass valve Capillary tube Outdoor coil thermistor (RT) Restrictor valve Capillary tube istributor with strainer PCH- PCH- Capillary tube O...0 I...-R0 O...0 I...0-R00 Refrigerant pipe Ball valve (option) (with service port) 9.mm( /8") (with heat insulator) Thermal switch Strainer PUH- (O...0 I...-R80) PUH- (O...0 I...-R00) PCH-AK / PUH-TKSA.TH PCH-AK / PUH-TKSA.TH Indoor unit Indoor heat exchanger Indoor coil thermistor TH Restrictor valve Strainer Refrigerant pipe (option) 9.0mm( /") Ball valve (with heat insulator) Strainer Flexible tube Flared connection Service port Oil separator -way valve Accumulator High pressure control switch Service port Compressor Outdoor unit Outdoor heat exchanger Bypass valve Capillary tube Outdoor coil thermistor (RT) Restrictor valve Capillary tube istributor with strainer PCH- PCH- Capillary tube O...0 I...-L0 O...0 I...0-L00 Refrigerant pipe Ball valve (option) (with service port) 9.mm( /8") (with heat insulator) Thermal switch Strainer PUH- (O...0 o I...-L80) o PUH- (O...0 o I...-L0) o PR 0

31 8 TROUBLESHOOTIN 8-. TROUBLESHOOTIN <Error code display by self-diagnosis and actions to be taken for service (summary)> Present and past error codes are logged and displayed on the wired remote controller or controller board of outdoor unit. Actions to be taken for service,which depends on whether or not the the inferior phenomenon is reoccurring at service, are summarized in the table below. Check the contents below before investigating details. Unit conditions at service Error code Actions to be taken for service (summary) The inferior phenomenon is reoccurring. The inferior phenomenon is not reoccurring. isplayed Not displayed Logged Not logged Judge what is wrong and take a corrective action according to SELF-IANOSIS ACTI TABLE (8-). Identify the cause of the inferior phenomenon and take a corrective action according to TROUBLESHOOTIN BY INFERIOR PHENOMENA (8-). Consider the temporary defects such as the work of protection devices in the refrigerant circuit including compressor, poor connection of wiring, noise and etc. Re-check the symptom, and check the installation environment, refrigerant amount, weather when the inferior phenomenon occurred, and wiring related. Reset error code logs and restart the unit after finishing service. There is no abnormality in electrical components, controller boards, and remote controller. Recheck the abnormal symptom. Identify the cause of the inferior phenomenon and take a corrective action according to TROUBLESHOOTIN BY INFERIOR PHENOMENA (8-). Continue to operate unit for the time being if the cause is not ascertained. There is no abnormality in electrical components, controller boards, remote controller etc. 8-. MALFUNCTI-IANOSIS METHO BY REMOTE CTROLLER <In case of trouble during operation> When a malfunction occurs to air conditioner, both indoor unit and outdoor unit will stop and operation lamp blinks to inform unusual stop. Wired remote controller B E Turn on the power. Press the [CHECK] button twice. Set address with [TEMP] button if system control is used. Press the [/OFF] button to stop the self-check. A CHECK button B Address C TEMP. button C BACK ERROR COE TEMP. MENU /OFF MITOR/SET AY /OFF FILTER CHECK TEST B ERROR COE E IC : Indoor unit OC: Outdoor unit E Check code : No trouble generated in the past. F F F F : No corresponding unit. F Unit No. PAR-MAA CLOCK OPERATI CLEAR ERROR COE Timer /OFF button A F <To delete check code> isplay the error code at the self-check result display screen. The address for self-check will blink when the /OFF button is pressed twice within three seconds.

32 Wired remote controller Check code Symptom Remark P Intake sensor error P Pipe (TH) sensor error P rain sensor error P PA rain pump error Forced compressor stop P Freezing/ Overheating protection operation P8 Pipe temperature error / Outdoor unit error E, E Remote controller signal receiving error Fb Indoor unit control system error (memory error, etc.) E0, E E, E Remote controller transmission error Remote controller control board error On wired remote controller Check code displayed in the LC. If the unit cannot be operated properly after the above test run has been performed, refer to the following table to remove the cause. Symptom Cause Wired remote controller For about For about minutes after power-on,operation of the remote controller is not possible PLEASE WAIT minutes after power-on due to system start-up. (Correct operation) Connector for the outdoor unit s protection device is not connected. PLEASE WAIT Error code Reverse or open phase wiring for the outdoor unit s power terminal block isplay messages do not appear even when operation switch is turned (operation lamp does not light up). After about minutes has expired after power-on Incorrect wiring between indoor and outdoor units Remote controller wire short On the wireless remote controller with condition above, following phenomena take place. No signals from the remote controller are accepted. Operation lamp is blinking. The buzzer makes a short piping sound. Note: Operation is not possible for about 0 seconds after cancellation of function selection. (Correct operation) For description of each LE (LE, ) provided on the indoor controller, refer to the following table. LE (power for microcomputer) Indicates whether control power is supplied. Make sure that this LE is always lit. LE (power for wired remote controller) Indicates whether power is supplied to the wired remote controller. This LE lights only in the case of the main indoor unit.

33 8-. SELF-IANOSIS ACTI TABLE Note: Refer to the manual of outdoor unit for the details of display such as F, U, and other E. Error Code Meaning of error code and detection method Cause Countermeasure Abnormality of room temperature thermistor (TH) The unit is in -minute resume prevention mode if short/open of thermistor is detected. Abnormal if the unit does not reset normally after minutes. (The unit returns to normal operation, if it has normally reset.) Constantly detected during cooling, drying, and heating operation. efective thermistor characteristics Contact failure of connector (CN0) on the indoor controller board (Insert failure) Breaking of wire or contact failure of thermistor wiring efective indoor controller board Check resistance value of thermistor. 0:.0k" 0: 9.k" 0:.k" 0:.k" 0:.0k" If you put force on (draw or bend) the lead wire with measuring resistance value of thermistor breaking of wire or contact failure can be detected. P Short: 90: or more Check contact failure of connector (CN0) on Open: -0: or less the indoor controller board. Refer to 8-. Turn the power back on and check restart after inserting connector again. Check room temperature display on remote controller. Replace indoor controller board if there is abnormal difference with actual room temperature. P P P Abnormality of pipe temperature thermistor/liquid (TH) The unit is in -minute resume prevention mode if short/open of thermistor is detected. Abnormal if the unit does not reset normally after minutes. (The unit returns to normal operation, if it has normally reset.) Constantly detected during cooling, drying, and heating (except defrosting) operation. Short: 90: or more Open: -0: or less Abnormality of drain sensor (S) Suspensive abnormality, if short/open of thermistor is detected for 0 seconds continuously. Turn off compressor and indoor fan. Short/open is detected for 0 seconds continuously during suspensive abnormality. (The unit returns to normal operation, if it has normally reset.) etect the following condition. uring cooling and drying operation. In case that pipe <liquid> temperature - room temperature <-0deg (Except defrosting) When pipe <liquid> temperature or room temperature is short/open temperature. uring drain pump operation. Malfunction of drain pump (P) Suspensive abnormality, if thermistor of drain sensor is let heat itself and temperature rises slightly. Turn off compressor and indoor fan. rain pump is abnormal if the condition above is detected during suspensive abnormality. Constantly detected during drain pump operation. efective thermistor characteristics Contact failure of connector (CN) on the indoor controller board (Insert failure) Breaking of wire or contact failure of thermistor wiring efective refrigerant circuit is causing thermistor temperature of 90: or more or -0: or less. efective indoor controller board efective thermistor characteristics Contact failure of connector (CN) on the indoor controller board. (Insert failure) Breaking of wire or contact failure of drain sensor wiring efective indoor controller board Malfunction of drain pump efective drain Clogged drain pump Clogged drain pipe Attached drop of water at the drain sensor rops of drain trickles from lead wire. Clogged filter is causing wave of drain. efective indoor controller board. Turn the power off, and on again to operate after check. Check resistance value of thermistor. For characteristics, refer to (P) above. Check contact failure of connector (CN) on the indoor controller board. Refer to 8-. Turn the power on and check restart after inserting connector again. Check pipe <liquid> temperature with remote controller in test run mode. If pipe <liquid> temperature is exclusively low (in cooling mode) or high (in heating mode), refrigerant circuit may have defective. Check pipe <liquid> temperature with remote controller in test run mode. If there is exclusive difference with actual pipe <liquid> temperature, replace indoor controller board. Turn the power off, and on again to operate after check. Check resistance value of thermistor. 0:.0k" 0:.9k" 0:.k" 0:.8k" 0:.k" Check contact failure of connector (CN) on the indoor controller board. Refer to 8-. Turn the power back on and check restart after inserting connector again. Replace indoor controller board if drain pump operates with the line of drain sensor connector CN- and is short-circuited, and abnormality reappears. Turn the power off, and on again to operate after check. Check if drain-up machine works. Check drain function. Check the setting of lead wire of drain sensor and check clogs of the filter. Replace indoor controller board if drain pump operates with the line of drain sensor connector CN- and is short-circuited and abnormality reappears. Refer to 8-. Turn the power off, and on again to operate after check.

34 Error Code Meaning of error code and detection method Cause Countermeasure P Freezing/overheating protection is working Freezing protection ( mode) The unit is in six-minute resume prevention mode if pipe temperature stays under -: for minutes, minutes after the compressor started. Abnormal if it stays under -: for minutes again within minutes after -minute resume prevention mode. <Frost prevention mode> If pipe temperature is : or below when minutes has passed after compressor starts operating, unit will start operating in frost prevention mode which stops compressor operation. After that, when pipe temperature stays 0: or more for minutes, frost prevention mode will be released and compressor will restart its operation. Overheating protection ( mode) The units is in -minute resume prevention mode if pipe temperature is detected as over 0: after the compressor started. Abnormal if the temperature of over 0: is detected again within 0 minutes after -minute resume prevention mode. ( or drying mode) Clogged filter (reduced airflow) Short cycle of air path Low-load (low temperature) operation beyond the tolerance range efective indoor fan motor Fan motor is defective. Indoor controller board is defective. efective outdoor fan control Overcharge of refrigerant efective refrigerant circuit (clogs) ( mode) Clogged filter (reduced airflow) Short cycle of air path Over-load (high temperature) operation beyond the tolerance range efective indoor fan motor Fan motor is defective. Indoor controller board is defective. efective outdoor fan control Overcharge of refrigerant efective refrigerant circuit (clogs) 8 Bypass circuit of outdoor unit is defective. ( or drying mode) Check clogs of the filter. Remove shields. Measure the resistance of fan motor's winding. Measure the output voltage of fan's connector (FAN) on the indoor controller board. WThe indoor controller board should be normal when voltage of AC 0~0V is detected while fan motor is connected. Refer to 8-. Check outdoor fan motor. Check operating condition of refrigerant circuit. ( mode) Check clogs of the filter. Remove shields. Measure the resistance of fan motor's winding. Measure the output voltage of fan's connector (FAN) on the indoor controller board. WThe indoor controller board should be normal when voltage of AC 0~0V is detected while fan motor is connected. Refer to 8-. Check outdoor fan motor. ~8Check operating condition of refrigerant circuit. P8 Abnormality of pipe temperature < mode> etected as abnormal when the pipe temperature is not in the cooling range minutes later of compressor start and minutes later of the liquid pipe is out of cooling range. Note ) It takes at least 9 min. to detect. Note ) Abnormality P8 is not detected in drying mode. range : - deg ] (TH-TH) TH: Liquid pipe temperature TH: Intake temperature < mode> When 0 seconds have passed after the compressor starts operation and the hot adjustment mode has finished, the unit is detected as abnormal when condenser/evaporator pipe temperature is not in heating range within 0 minutes. Note ) It takes at least minutes to detect abnormality. Note ) It excludes the period of defrosting (etection restarts when defrosting mode is over) range : deg [ (TH-TH) Slight temperature difference between indoor room temperature and pipe temperature thermistor Shortage of refrigerant isconnected holder of pipe thermistor efective refrigerant circuit Converse connection of extension pipe (on plural units connection) Converse wiring of indoor/ outdoor unit connecting wire (on plural units connection) efective detection of indoor room temperature and pipe temperature thermistor Stop valve is not opened completely. ~ Check pipe temperature with room temperature display on remote controller. Check converse connection of extension pipe or converse wiring of indoor/outdoor unit connecting wire. Abnormality in outdoor unit Wrong wiring of indoor/outdoor connecting wire Reversed phase Protection device is working amaged outdoor coil thermistor Check the indoor/outdoor connecting wire. Change the connection of electric wiring. Check the protection device. Measure the resistance of the outdoor coil thermistor. If the resistance is normal, replace the outdoor controller board.

35 Error Code Meaning of error code and detection method Cause Countermeasure E0 or E E or E Remote controller transmission error(e0)/signal receiving error(e) Abnormal if main or sub remote controller can not receive normally any transmission from indoor unit of refrigerant address 0 for minutes. (Error code : E0) Abnormal if sub remote controller could not receive for any signal for minutes. (Error code: E0) Abnormal if indoor controller board can not receive normally any data from remote controller board or from other indoor controller board for minutes. (Error code: E) Indoor controller board cannot receive any signal from remote controller for minutes. (Error code: E) Remote controller transmission error(e)/signal receiving error(e) Abnormal if remote controller could not find blank of transmission path for seconds and could not transmit. (Error code: E) Remote controller receives transmitted data at the same time, compares the data, and when detecting it, judges different data to be abnormal 0 continuous times. (Error code: E) Abnormal if indoor controller board could not find blank of transmission path. (Error code: E) Indoor controller board receives transmitted data at the same time, compares the data,and when detecting it, judges different data to be abnormal 0 continuous times. (Error code: E) Contact failure at transmission wire of remote controller All remote controllers are set as sub remote controller. In this case, E0 is displayed on remote controller, and E is displayed at LE (LE, LE) on the outdoor controller circuit board. Mis-wiring of remote controller efective transmitting receiving circuit of remote controller efective transmitting receiving circuit of indoor controller board of refrigerant address 0 Noise has entered into the transmission wire of remote controller. Two remote controller are set as main. (In case of two remote con trollers) Remote controller is connected with two indoor units or more. Repetition of refrigerant address efective transmitting receiving circuit of remote controller efective transmitting receiving circuit of indoor controller board Noise has entered into transmission wire of remote controller. Check disconnection or looseness of indoor unit or transmission wire of remote controller. Set one of the remote controllers main. If there is no problem with the action above. Check wiring of remote controller. Total wiring length: max.00m (o not use cable x or more) The number of connecting indoor units: max.units The number of connecting remote controller: max.units When it is not the above-mentioned problem of ~ iagnose remote controllers. a) When RC OK is displayed, Remote controllers have no problem. Put the power off, and on again to check. If abnormality generates again, replace indoor controller board. b) When RC N is displayed, Replace remote controller. c) When RC E is displayed, d) When ERC 00-0 is displayed, [ c),d) Noise may be causing abnormality. ] If the unit is not normal after replacing indoor controller board in group control, indoor controller board of address 0 may be abnormal. Set a remote controller to main, and the other to sub. Remote controller is connected with only one indoor unit. The address changes to a separate setting. ~ iagnose remote controller. a) When RC OK is displayed, remote controllers have no problem. Put the power off,and on again to check. When becoming abnormal again, replace indoor controller board. b)when RC N is displayed, replace remote controller. c)when RC E or ERC 00- is displayed, noise may be causing abnormality.

36 Error Code Meaning of error code and detection method Cause Countermeasure Fb Abnormality of indoor controller board Abnormal if data cannot be normally read from the nonvolatile memory of the indoor controller board. efective indoor controller board Replace indoor controller board. E or E Abnormality of remote controller control board Abnormal if data cannot be normally read from the nonvolatile memory of the remote controller control board. (Error code: E) Abnormal if the clock function of remote controller cannot be normally operated. (Error code: E) efective remote controller Replace remote controller. PA (0) (00) Forced compressor stop (due to water leakage abnormality) When the intake temperature subtracted with liquid pipe temperature is less than -0:, drain sensor is detected whether it is soaked in the water or not at the interval of 90 seconds. (rain pump will start operating when the drain sensor is detected to be soaked in the water.) The unit has a water leakage abnormality when the following conditions, a and b, are satisfied while the above-mentioned detection is performed. a) The drain sensor is detected to be soaked in the water 0 times in a row. b) The intake temperature subtracted with liquid pipe temperature is detected to be less than -0: for a total of 0 minutes. (When the drain sensor is detected to be NOT soaked in the water, the detection record of a and b will be cleared.) The drain sensor detection is performed in operations other than cooling. (When the unit stops operating, during heating or fan operation, when the unit stops because of some abnormality) *Once the water leakage abnormality is detected, abnormality state will not be released until the main power is reset. ) rain pump trouble ) rain defective rain pump clogging rain pipe clogging ) Open circuit of drain sensor side heater ) Contact failure of drain sensor connector ) ew condensation on drain sensor rain water descends along lead wire. rain water waving due to filter clogging ) Extension piping connection difference at twin, triple, quadruple system ) Mis-wiring of indoor/ outdoor connecting at twin, triple, quadruple system 8) Room temperature thermistor / liquid pipe temperature thermistor detection is defective. Check the drain pump. Performance Please confirm whether water can be drained. Confirm the resistance of the drain sensor side heater. Check the connector contact failure. Check the drain sensor leadwire mounted. Check the filter clogging Check the piping connection. Check the indoor/ outdoor connecting wires. Check the room temperature display of remote controller. Check the indoor liquid pipe temperature display of outdoor controller board.

37 8-. TROUBLESHOOTIN BY INFERIOR PHENOMENA Phenomena Cause Countermeasure ()LE on indoor controller board is off. When LE on indoor controller board is also off. Power supply of 0~0V AC is not supplied to indoor unit. efective indoor controller board efective indoor power board Check the voltage of indoor power supply terminal block (L,N). When AC0~0V is not detected. Check the power supply wiring. When AC0~0V is detected. -Check (below). Check voltage output from CNK on indoor controller board. When AC0~0V is not detected. Check the fuse on indoor controller board. Check the wiring connection between indoor power supply terminal block and CN on indoor controller board. When AC0~0V is detected. -Check (below). Check voltage output from CNS on indoor power board. When no voltage output. Check the wiring connection between CNK on indoor controller board and CNSK on indoor power board. If no problem are found,indoor power board is defective. When C.~.V is detected. Check the wiring connection between CNS on indoor power board and CN on indoor power board. If no problem are found,indoor controller board is defective. When LE on indoor controller board is lit. Mis-setting of main/sub for indoor unit (There is no unit corresponding to main unit.) Reconfirm the setting of main/sub for indoor unit Set the main unit. Set main/sub using SW- on indoor controller board. ()LE on indoor controller board is blinking. When LE on indoor controller board is also blinking. Connection failure of indoor/outdoor unit connecting wire When LE is lit. Mis-wiring of remote controller wires When indoor units are wired in one refrigerant system, each indoor unit sets main unit. (SW-) Short-cut of indoor/outdoor unit connecting wire Check indoor/outdoor unit connecting wire for connection failure. Check the connection of remote controller wires in case of twin triple indoor unit system. When or more indoor units are wired in one refrigerant system, connect remote controller wires to one of those units. Remove indoor/outdoor connecting wires and check LE on indoor controller board. When LE is blinking, check the shortcut of indoor/outdoor connecting wires. When LE is lit, connect indoor/outdoor connecting wires again, and; if LE is blinking, outdoor unit s controller board is defective; if LE is lit, connection failure of indoor/outdoor terminal block etc. has returned to normal. Short-cut of remote controller wires efective remote controller Remove remote controller wires and check LE on indoor controller board. When LE is blinking, check the short-cut of remote controller wires. When LE is lit, connect remote controller wires again and: if LE is blinking, remote controller is defective; if LE is lit, connection failure of remote controller terminal block etc. has returned to normal.

38 Phenomena Cause Countermeasure ()Upward/downward vane performance failure ()Receiver for wireless remote controller The vane is not downward during defrosting and heat preparation and when the thermostat is OFF in HEAT mode. (Working of COOL protection function) Vane motor does not rotate. efective vane motor Breaking of wire or connection failure of connector Up/down vane setting is No vanes. Upward/downward vane does not work. The vane is set to fixed position. Weak batteries of wireless remote controller Contact failure of connector (CNB) on wireless remote controller board (Insert failure) Contact failure of connector (CN90) on indoor controller board(insert failure) Contact failure of connector between wireless remote controller board and indoor controller board 8-. TEST RUN AN EMERENCY OPERATI 8--. Before test run 8--. When wired remote controller or indoor unit micro computer troubles 8 Normal operation (The vane is set to horizontal regardless of remote control.) Check (left). Check the vane motor. (Refer to How to check the parts.) Check for breaking of wire or connection failure of connector. Check Up/down vane setting. (Unit function selection by remote controller). Normal operation (Each connector on vane motor side is disconnected.) Replace batteries of wireless remote controller. ~ Check contact failure of each connector. If no problems are found of connector, replace indoor controller board. When the same trouble occurs even if indoor controller board is replaced, replace wireless remote controller board. After completing installation and the wiring and piping of the indoor and outdoor units, check for refrigerant leakage, looseness in the power supply or control wiring, wrong polarity, and no disconnection of one phase in the supply. Use a 00-volt megohmmeter to check that the resistance between the power supply terminals and ground is at least.0m". o not carry out this test on the control wiring (low voltage circuit) terminals. Warning: o not use the air conditioner if the insulation resistance is less than.0m". Insulation resistance 8--. Test run (Using wired remote controller) F E B C PAR-MAA TEST RUN COOL, HEAT BACK H ûc TEMP. MENU /OFF MITOR/SET AY CLOCK ûc OPERATI A /OFF button B Test run display C Indoor temperature liquid line temperature display /OFF lamp E Power display SIMPLE /OFF FILTER CHECK CLEAR TEST I M A F Error code display Test run remaining time display Set temperature button H Mode selection button I Fan speed button M TEST button Turn on the power at least hours before the test run. Press the [TEST] button twice. "TEST RUN" liquid crystal display Press the [Mode selection] button. Make sure that wind is blown out. Press the [Mode selection] button and switch to the cooling (or heating) mode. Make sure that cold (or warm) wind is blown out. Press the [Fan speed] button. Make sure that the wind speed is switched. Check operation of the outdoor unit fan. Release test run by pressing the [/OFF] button. Stop 8 Register a telephone number. The telephone number of the repair shop, sales office, etc., to contact if an error occurs can be registered in the remote controller. The telephone number will be displayed when an error occurs. For registration procedures, refer to the operation manual for the indoor unit. [Emergency operation procedure].when the indoor unit microcomputer has failed, but all other components work properly, if you set the switch(swe,sw)on the indoor control board, the indoor unit will begin Emergency Operation..When you activate emergency operation of the cooling or heating, you have to set the switch(swe)and switch(sw)on indoor controller. SWE: Indoor fan is running high speed. rain-up machine(optional)is working. SW-: Emergency operation of cooling mode. SW-,: Emergency operation of heating mode..before you activate emergency operation, check the following points: Emergency operation cannot be activated when: The outdoor unit malfunctions. The indoor fan malfunctions. Emergency operation becomes continuous only by switching the power source on / off. / OFF on the remote control or temperature control etc. does not function. Avoid operating for a long time when the outdoor unit begins defrosting while emergency operation of the heating is activated, because it will start to blow cold air. Emergency cooling should be limited to 0 hours maximum (The indoor unit heat exchanger may freeze). After emergency operation has been deactivated, set the switches etc. to their original positions. Movement of the vanes does not work in emergency operation, therefore you have to slowly set them manually to the appropriate position.

39 8-. HOW TO CHECK THE PARTS PCH-,.,,,, AK PCH-,.,,,, AKH Parts name Room temperature thermistor (TH) Pipe temperature thermistor (TH) Normal.k"~9.k" Check points isconnect the connector then measure the resistance using a tester. (Surrounding temperature 0:~0:) Abnormal Open or short (Refer to the next pege for a detail.) Fan motor Relay connector Orange Red Pink Vane motor Red White Black Protector OFF : 0i : : 80i 0: M Yellow Brown Blue Measure the resistance between the terminals using a tester. (Winding temperature 0:) Motor terminal or Relay connector Red Black White Black Connector Brown Yellow Brown Blue Red Orange Red Pink AK(H) 0." 9." AK(H) 8~"., AK(H).0".8" Normal Normal., AK(H) 0~0" AK(H).".", AK(H) Abnormal 0." 0." Open or short Abnormal Open or short Pink Orange Red M Yellow Blue Connector Brown Yellow Brown Blue Red Orange Red Pink Normal,, AK(H) 0~0" Abnormal Open or short Heater (Only PCH-AKH) Measure the resistance of each heater element by using a tester. (Surrounding temperature 0:) AKH." 0. 80V., AKH 9." 0. 80V Normal AKH." V, AKH.".0 80V Abnormal Open or short rain-up mechanism (Option) ray ray Measure the resistance between the terminals using a tester. (Winding temperature 0:) Normal 9" Abnormal Open or short Contactor (Only PCH-AKH) Measure the resistance between the terminals using a tester. Normal 88H 0" Abnormal Open or short 9

40 <Thermistor Characteristic graph> Thermistor for lower temperature Room temperature thermistor(th) Pipe temperature thermistor(th) 0 < Thermistor for lower temperature > 0 Thermistor R0=kΩ ± % Fixed number of B=80 ± % Rt=exp { 80( +t ) } 0: kω 0: 9.kΩ 0:.kΩ :.kω 0:.kΩ 0:.0kΩ Resistance (k") Temperature (:) 8-.TEST POINT IARAM 8--. Power board PCH-AK PCH-AKH PCH-.AK PCH-.AKH PCH-AK PCH-AKH PCH-AK PCH-AKH PCH-AK PCH-AKH PCH-AK PCH-AKH CNS Connect to the indoor controller board (CN) Between to.-.v C (Pin (+)) CNSK Connect to the indoor controller board (CNK) Between to 0-0V AC 0

41 8--. Indoor controller board PCH-AK PCH-AKH PCH-.AK PCH-.AKH PCH-AK PCH-AKH PCH-AK PCH-AKH PCH-AK PCH-AKH PCH-AK PCH-AKH CN Connect to the indoor power board (CNS) (.~.V C) LE Power supply (I.B) LE Power supply (R.B) SW Emergency operation CN Connect to the terminal block(tb) (Remote controller connecting wire) (0.~.V C) CN0 Transmission (Indoor/outdoor) CNK Connect to the indoor power board (CNSK) (0~0V AC) CN0 Room temperature thermistor (TH) CN Pipe temperature thermistor/liquid (TH) FUSE (. A 0 V) CN rain sensor (S) CN Power supply input (0~0V AC) CN90 Connect to the wireless remote controller board (CNB) CNP rain-pump output (P) (0~0V AC) CNV Vane motor output (MV) CN Connector (HA terminal-a) CN Centrally control CN0/9 (RE) CN Heater output (V C) SWE Emergency operation CN Remote switch CNL Connector (LOSSNAY) FAN Fan motor output SW System setting Jumper wire J, J Pair number setting with wireless remote controller SW Capacity setting SW Model setting

42 8-8. FUNCTIS OF IP SWITCH AN JUMPER WIRE Each function is controlled by the dip switch and the jumper wire on control p.c. board. Jumper wire Functions Setting by the dip switch and jumper wire Remarks SW Model settings OFF MOELS SW PCH-AK(H) OFF PCH-.AK(H) OFF SW Capacity settings PCH-AK(H) PCH-AK(H) OFF OFF PCH-AK(H) OFF PCH-AK(H) OFF SW System settings 8 OFF SW- Main/Sub setting OFF : Main : Sub SW- Rotaion operation setting OFF : Not avairable : avairable J J Pair number setting with wireless remote controller Wireless remote controller setting 0 ~ 9 Control PCB setting J J <Settings at time of factory shipment> Wireless remote controller: 0 Control PCB: (for both J and J) Four pair number settings are supported. The pair number settings of the wireless remote controller and indoor control PCB (J/J) are given in the table on the left. (' ' in the table indicates the jumper line is disconnected.)

43 8-9. OUTOOR UNIT SERVICE FUNCTIS (OUTOOR CTROLLER BOAR) () Compulsory defrosting When all of the following conditions are satisfied, pressing SW starts the compulsory defrosting. uring HEAT mode The compressor is. The outdoor coil temperature is being displayed by LE. (Outdoor controller board dip switch SW- : OFF, SW- : ) The outdoor coil thermistor reads 8 C or below. The operation state and the termination conditions of the compulsory defrosting are the same as those of the normal defrosting. As an exception, the defrost interval after the defrosting completion is 0 minutes. () Fixed fan-output While the compressor is operating (except during defrosting) and the fan output step is indicated by LE, pressing SW fixes the fan output. The fixed fan-output can be released when any of the following conditions are satisfied. SW is pressed again. SW setting is changed. The compressor stops. efrosting operation starts. () Function of switches on the outdoor controller board SW: Clears the check code memory (push-button switch) SW: Switches the output state indication and the check code display (push-button switch) SW-,: Switches the output state indication items (dip switch) () 00% fan output Fan output is fixed to 00% by shorting the connector CN. However, the fan stops during compressor OFF or defrosting. Open-circuit of CN restarts the normal fan control. () Time shortening Short circuit of the connector CN shortens the time as follows Fan control period: 0 seconds seconds Three-minutes time delay function : minutes seconds Max. time of defrosting : minutes seconds efrost interval : 0 ~ 0 minutes ~ seconds Compressor /OFF time for bypass valve /OFF : 0 minutes seconds Compressor time to start other functions : x minutes x seconds Crankcase heater operation : hour seconds () Crankcase heater control With jumper wire J The crankcase heater is from when the power is turned until the compressor starts, and then turns one hour after the compressor stops. Without jumper wire J The crankcase heater is from when the power is turned until the compressor starts, and repeats -hour and - hour OFF, after the compressor stops.

44 9 FUNCTI SETTIN 9-. UNIT FUNCTI SETTIN BY THE REMOTE CTROLLER Each function can be set according to necessity using the remote controller. The setting of function for each unit can only be done by the remote controller. Select function available from the table. () Functions available when setting the unit number to 00 (Select 00 referring to setting the indoor unit number.) W The functions below are available only when the wired remote controller is used.the functions are not available for floor standing models. <Table > Function selections Function Settings Mode No. Setting No. Power failure automatic recovery Indoor temperature detecting LOSSNAY connectivity Power supply voltage Frost prevention temperature Humidifier control Rotation OFF Indoor unit's (Main) internal sensor Remote controller's internal sensor w Not supported Supported (indoor unit not equipped with outdoor air intake) Supported (indoor unit equipped with outdoor air intake) 0V 0V,0V : (Normal) -: When the compressor operates, the humidifier also operates. When the fan operates, the humidifier also operates. h cycle 8cycle Back up function Initial setting (when sent from the factory) Remarks The setting is applied to all the units in the same refrigerant system. () Functions available when setting the unit number to 0-0 or AL (0 in case of wireless remote controller) When setting functions for an indoor unit in an independent system, set the unit number to 0 referring to setting the indoor unit number. When setting functions for a simultaneous- Twin indoor unit system, set the unit number to 0 to 0 for each indoor unit in case of selecting different functions for each unit referring to setting the indoor unit number. When setting the same functions for an entire simultaneous Twin indoor unit system, set refrigerant address to AL (0 in case of wireless remote controller) referring to setting the indoor unit number. Function Settings Initial setting (Factory setting) - : Not available Mode Setting Ceiling -Way cassette Ceiling Wall Floor No. No. concealed suspended mounted standing PLH-AAK(H) PEH-EAK(H) PLH-KAK(H) PCH-AK(H) PEH-EAK(H) PKHAKL(H) PKA-FAKL(H) PSH-AK(H) Filter sign 00Hr 00Hr 0 No filter sign indicator Air flow Quiet Standard (Fan speed) Standard High ceiling High ceiling High ceiling} No.of air outlets directions directions directions Optional high efficiency Not supported filter Supported Vane setting No vanes (Vane No. setting:plh-aak(h)only) Vane No. setting Vane No. setting Energy saving air isabled flow ( mode) Enabled Optional humidifier Not supported (PLH-AAK(H) only) Supported Vane differential setting No. setting (TH: -8:) - - in heating mode No. setting (Standard, TH:8-:) - - (cold wind prevention) No. setting (TH: -8:) - - Swing Not available - - Available - - Set temperature in heating Available mode ( deg up) Not available Fan speed when the Extra low heating thermostat is OFF Stop Set fan speed Quiet operation mode isabled (Standard) of PLH-AAK(H)(Fan speed) Enabled (Quiet operation mode) Fan speed when the Set fan speed cooling thermostat is OFF Stop etection of abnormality of Available 8 the pipe temperature (P8) Not available

45 Rotation setting (Function setting mode No.0) Function setting Features Indoor controller board Mode No. Setting No. SW- setting SW- setting 9 0 Each system operates alternately for (hours hours. cycle) 0 (8hours cycle) Each system operates alternately for 8hours. OFF : Main : Sub 0 (Back up function) When abnormality occurs while operating, it changes as a back up unit, and operating continues. This system can correspond only by the pattern of two refrigerant group by : (indoor and outdoor unit combination) systems. Example of unit's operation (Setting No. = 0 or 0) Main indoor unit OFF Operation starts Main Sub Sub Main Main Unit is abnormal Main Sub Outdoor unit Sub indoor unit OFF (Setting No. = 0) Main indoor unit OFF h h (Setting No. = 0 8hours cycle) Main Unit is abnormal Operation starts Main Sub Main Remote Controller Sub Indoor unit Sub indoor unit OFF 9--. Selecting functions using the wired remote controller First, try to familiarize yourself with the flow of the function selection procedure. In this section, an example of setting the room temperature detection position is given. For actual operations, refer to steps to 0. Setting number Address Unit number Mode number I F A E B Modes 0 to can be activated by pressing buttons A and B simultaneously, and modes to 8 by pressing buttons B and J. C J

46 Selecting functions using the wired remote controller Check the function selection setting. Switch to function setting mode. (Press A and B at the same time with the remote controller stopped.) For modes and higher, press J and B at the same time. Specify address Specify unit No. (Use C and.) Refer to address unit No. to the figure below Enter the setting. (Press E.) Select mode No. 0 (room temperature detection position). Select setting No. 0 (remote controller fixed). (Use F and.) (Specified indoor unit: BLOW operation) NO YES Change refrigerant address unit No. 8 Enter the setting. (Press E.) Example: Selecting room temperature detection position 9 Finished YES NO 0 Ending function display (Press A and B at the same time.) The above procedure must be carried out only if changes are necessary. : system Simultaneous twin system Rotation system Outdoor unit Outdoor unit Outdoor unit Outdoor unit Indoor unit Main indoor unit Sub indoor unit Main indoor unit Sub indoor unit Remote controller Remote controller Remote controller Indoor unit address = 00 unit No. = 0 Main indoor unit address = 00 unit No. = 0 Sub indoor unit address = 0 unit No. = 0 Main indoor unit address = 00 unit No. = 0 Sub indoor unit address = 0 unit No. = 0

47 [Operating Procedure] Check the setting items provided by function selection. If settings for a mode are changed by function selection, the functions of that mode will be changed accordingly. Check all the current settings according to steps to, fill in the "Check" column in Table, and then change them as necessary. For factory settings, refer to the indoor unit's installation manual. Switch off the remote controller. Set the outdoor address. A Hold down the FILTER and ( mode or more) B TEST C Press the [ CLOCK] buttons ( and ) to select the desired buttons simultaneously for at least two seconds. FUNCTI will start to flash, address. The address changes from "00" to "". SELECTI and then the remote controller's display content will change as shown below. Address display section * If the unit stops after FUNCTI flashed for two seconds or "88" flashes in the room temperature display area for two seconds, a transmission error may have occurred. SELECTI Check to see if there are any sources of noise or interference near the transmission path. Note If you have made operational mistakes during this procedure, exit function selection (see step 0), and then restart from step. Set the indoor unit number. Press the /OFF button so that "- -" flashes in the unit number display area. Unit number display section C Press the [ CLOCK] buttons ( and ) to select the unit number of the indoor unit for which you want to perform function selection. The unit number changes to "00", "0", "0","0",0" and "AL" each time a button is pressed. * To set modes 0 to 0 or to select unit number "00". * To set modes 0 to or to 8 carry out as follows: To set each indoor unit individually, select "0" to "0". To set all the indoor units collectively, select "AL". Confirm the address and unit number. E Press the MOE button to confirm the address and unit number. After a while, "- - " will start to flash in the mode number display area. Mode number display section * "88" will flash in the room temperature display area if the selected address does not exist in the system. Furthermore, if "F" appears and flashes in the unit number display area and the address display area also flashes, there are no units that correspond to the selected unit number. In this case, the address and unit number may be incorrect, so repeat steps and to set the correct ones. E When the address and unit number are confirmed by pressing the MOE button, the corresponding indoor unit will start fan operation. This helps you find the location of the indoor unit for which you want to perform function selection. However, if "00" or "AL" is selected as the unit number, all the indoor units corresponding to the specified address will start fan operation. Example) When the address is set to 0 and the unit number is address Indoor unit esignate operation Outdoor unit Main Remote controller Fan draft * When grouping different systems, if an indoor unit other than the one to which the address has been set performs fan operation, there may be another address that is the same as the specified one. In this case, check the IP switch of the outdoor unit to see whether such a address exists. Sub Select the mode number. F Press the [ TEMP] buttons ( and ) to set the desired mode number. (Only the selectable mode numbers can be selected.) Mode number display section Mode number 0 = Indoor temperature detection Select the setting content for the selected mode. Press the MENU button. The currently selected setting number will flash, so check the currently set content. F Press the [ TEMP] buttons ( and ) to select the desired setting number. Setting number display section Setting number = Indoor unit operating average Setting number = Remote controller built-in sensor 8 Register the settings you have made in steps to. The mode number and setting number will stop flashing and remain lit, indicating the E Press the MOE button. The mode number and setting number will start end of registration. to flash and registration starts. * If " " is displayed for both the mode number and setting number and " " flashes in the room temperature display area, a transmission error may have occurred. Check to see if there are any sources of noise or interference near the transmission path. 9 If you wish to continue to select other functions, repeat steps to 8. 0 Complete function selection. A Hold down the FILTER and ( mode or more) TEST buttons simultaneously for at least two seconds. After a while, the function selection screen will disappear and the air conditioner OFF screen will reappear. * o not operate the remote controller for at least 0 seconds after completing function selection. (No operations will be accepted even if they are made.) Note If a function of an indoor unit is changed by function selection after installation is complete, make sure that a " " mark, etc., is given in the "Check" column of Table to indicate the change.

48 9-. FUNCTI SELECTI OF REMOTE CTROLLER The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when needed. Item.Change Language ("CHANE LANUAE").Function limit ("FUNCTI SELECTI").Mode selection ("MOE SELECTI").isplay change ("ISP MOE SETTIN") Item Language setting to display () Operation function limit setting (operation lock) ("LOCKIN FUNCTI") () Use of automatic mode setting ("SELECT AUTO MOE") () Temperature range limit setting ("LIMIT TEMP FUNCTI") () Remote controller main/sub setting ("CTROLLER MAIN/SUB") () Use of clock setting ("CLOCK") () Timer function setting ("WEEKLY TIMER") () Contact number setting for error situation ("CALL.") () Temperature display :/ F setting ("TEMP MOE :/ F") () Room air temperature display setting ("ROOM TEMP ISP SELECT") () Automatic cooling/heating display setting ("AUTO MOE ISP C/H") Item (Setting content) isplay in multiple languages is possible. Setting the range of operation limit (operation lock) Setting the use or non-use of "automatic" operation mode Setting the temperature adjustable range (maximum, minimum) Selecting main or sub remote controller * When two remote controllers are connected to one group, one controller must be set to sub. Setting the use or non-use of clock function Setting the timer type Contact number display in case of error Setting the telephone number Setting the temperature unit (: or F) to display Setting the use or non-use of the display of indoor (suction) air temperature Setting the use or non-use of the display of "" or "" display during operation with automatic mode [Function selection flowchart] Refer to next page. [] Stop the air conditioner to start remote controller function selection mode. [] Select from item. [] Select from item. [] Make the setting. (etails are specified in item) [] Setting completed. [] Change the display to the normal one. (End) [etailed setting] [] -. CHANE LANUAE setting The language that appears on the dot display can be selected. Press the [ MENU] button to change the language. Japanese (JP), English (B), erman (), Spanish (E), Russian (RU), Italian (I), Chinese (CH), 8 French (F) [] -. Function limit () Operation function limit setting (operation lock) To switch the setting, press the [ /OFF] button. no : Operation lock setting is made on all buttons other than the [ /OFF] button. no : Operation lock setting is made on all buttons. OFF (Initial setting value) : Operation lock setting is not made * To make the operation lock setting valid on the normal screen, it is necessary to press buttons (Press and hold down the [FILTER] and [ /OFF] buttons at the same time for two seconds.) on the normal screen after the above setting is made.. () Use of automatic mode setting When the remote controller is connected to the unit that has automatic operation mode, the following settings can be made. To switch the setting, press the [ /OFF] button. (Initial setting value) : The automatic mode is displayed when the operation mode is selected. OFF : The automatic mode is not displayed when the operation mode is selected. () Temperature range limit setting After this setting is made, the temperature can be changed within the set range. To switch the setting, press the [ /OFF] button. LIMIT TEMP COOL MOE : The temperature range can be changed on cooling/dry mode. LIMIT TEMP HEAT MOE : The temperature range can be changed on heating mode. LIMIT TEMP AUTO MOE : The temperature range can be changed on automatic mode. OFF (initial setting) : The temperature range limit is not active. * When the setting, other than OFF, is made, the temperature range limit setting on cooling, heating and automatic mode is made at the same time. However the range cannot be limited when the set temperature range has not changed. To increase or decrease the temperature, press the [ TEMP ( ) or ( )] button. To switch the upper limit setting and the lower limit setting, press the [ ] button. The selected setting will flash and the temperature can be set. Settable range /ry mode : Lower limit: 9 : ~ 0: Upper limit: 0 : ~ 9: mode : Lower limit: : ~ 8: Upper limit: 8 : ~ : Automatic mode : Lower limit: 9 : ~ 8: Upper limit: 8 : ~ 9: [] -. Mode selection setting () Remote controller main/sub setting To switch the setting, press the [ /OFF] button. Main : The controller will be the main controller. Sub : The controller will be the sub controller. () Use of clock setting To switch the setting, press the [ /OFF] button. : The clock function can be used. OFF: The clock function cannot be used. () Timer function setting To switch the setting, press the [ /OFF] button (Choose one of the followings.). WEEKLY TIMER (initial setting): The weekly timer can be used. AUTO OFF TIMER: The auto off timer can be used. SIMPLE TIMER: The simple timer can be used. TIMER MOE OFF: The timer mode cannot be used. * When the use of clock setting is OFF, the "WEEKLY TIMER" cannot be used. () Contact number setting for error situation To switch the setting, press the [ /OFF] button. CALL OFF: The set contact numbers are not displayed in case of error. CALL **** *** **** : The set contact numbers are displayed in case of error. CALL_ : The contact number can be set when the display is as shown on the left. Setting the contact numbers To set the contact numbers, follow the following procedures. Move the flashing cursor to set numbers. Press the [ TEMP. ( ) and ( )] button to move the cursor to the right (left). Press the [ CLOCK ( ) and ( )] button to set the numbers. [] -. isplay change setting () Temperature display :/ F setting To switch the setting, press the [ /OFF] button. : : The temperature unit : is used. F: The temperature unit F is used. () Suction air temperature display setting To switch the setting, press the [ /OFF] button. : The suction air temperature is displayed. OFF: The suction air temperature is not displayed. () Automatic cooling/heating display setting To switch the setting, press the [ /OFF] button. : One of "Automatic cooling" and "Automatic heating" is displayed under the automatic mode is running. OFF: Only "Automatic" is displayed under the automatic mode. 8

49 Flowchart of Function Setting Setting language (English) Normal display (isplay when the air condition is not running) Hold down the E button and press the button for seconds. Remote controller function selection mode Hold down the E button and press the button for seconds. E Press the operation mode button. Press the TIMER MENU button. Press the TIMER /OFF button. Change Language Item Item ot display EN E E ES F RU IT E TEMP. MENU /OFF BACK MITOR/SET AY PAR-MAA CLOCK /OFF FILTER CHECK TEST OPERATI CLEAR I A B ZH FR C H Function selection E E JA Item OFF on on OFF OFF Operation lock setting is not used. (Initial setting value) Operation lock setting is except On/Off buttons. Operation lock setting is All buttons. The automatic mode is displayed when the operation mode is selected. (Initial setting value) The automatic mode is not displayed when the operation mode is selected. The temperature range limit is not active. (Initial setting value) The temperature range can be changed on cooling/dry mode. The temperature range can be changed on heating mode. The temperature range can be changed on automatic mode. Mode selection E OFF The remote controller will be the main controller. (Initial setting value) The remote controller will be the sub controller. The clock function can be used. (Initial setting value) The clock function can not be used. Weekly timer can be used. (Initial setting value) Auto off timer can be used. Simple timer can be used. Timer mode can not be used. OFF CALL- The set contact numbers are not displayed in case of error. (Initial setting value) The set contact numbers are displayed in case of error. isplay mode setting : F OFF OFF The temperature unit : is used. (Initial setting value) The temperature unit F is used. Room air temperature is displayed. (Initial setting value) Room air temperature is not displayed. One of "Automatic cooling" and "Automatic heating" is displayed under the automatic mode is running. (Initial setting value) Only "Automatic" is displayed under the automatic mode. 9

50 0 SYSTEM CTROL 0-. VARIETY OF SYSTEM CTROL FUNCTIS System Name System iagram Features A.Remote controller operation (Standard) B.Remote controller operation Use of two controllers enables operation of the air conditioner both from a distance and nearby. C.roup control operation Use of one remote controller to control multiple air conditioners with the same settings simultaneously. Indoor unit Outdoor unit Indoor unit Remote Controller Remote Controller * One of the wired remote controllers must be set as a sub remote controller. Remote Controller Inter face Indoor unit Outdoor unit There are two types of remote controllers: wired type and wireless type. Simultaneous twin indoor units are started or stopped simultaneously. Up to two remote controllers can be connected to one group. Simultaneous twin units are counted as each unit. Operation control by the latest command (last entered priority) Wired and wireless remote controllers can be combined as a pair. One group can consist of up to indoor units, and they can be started sequentially by connecting the remote controller to them and assigning an address to each inter face. Simultaneous twin units are counted as one unit. All the units belonging to the same group are operated in the same mode, but thermostats can be turned /OFF individually for each indoor unit. Up to two remote controllers can be connected. Parts Required in Addition to Standard System Components (Indoor/Outdoor Units, Remote Controller) Wired remote controller (additional) (PAR-MAA) Inter face MAC-9IF-E.Remote/local combined control operation Allows start/stop of the air conditioner from a distance, and prohibits/permits start/ stop from remote controllers. Relay box Indoor unit Remote Controller Remote operating panel All the air conditioners can be turned /OFF collectively from a distance. Operation can be switched between the remote operating panel and local controller. Operations (e.g., temperature adjustment, airflow, airflow direction) except for start/stop operations can be performed even if the operations from the local remote controllers are prohibits. In the case of simultaneous twin units, connect the controller to one indoor unit only. If connected to two indoor units, an error (operation stop) may occur. Control by an external timer is possible by connecting it. Remote /OFF adapter (PAC-SERA-E) Relay box (Part to be provided at your site) Remote operating panel (Part to be provided at your site) E.Operation by external signal Use of optional "remote / OFF adapter" enables remote control via relay. (Level signal) Remote /OFF adapter (PAC SERA-E) F.Control and remote display by external signal (extraction of monitor signal) Enables you to display the operation state and control start/stop from a distance. Adapter Indoor unit Remote Controller Remote display panel (operation, error) Extraction of non-voltage contact output Use of optional "remote operation adapter" and "remote display panel" (Part to be provided at your site) provides non-voltage contact outputs of signals (operation, error) and operation/stop input function. Extraction of C V contact output Use of optional "multiple remote controller adapter" and "remote display panel" (Part to be provided at your site) provides C V contact outputs of signals (operation, error) and operation/stop input function. Remote operation adapter (PAC-SF0RM-E) Remote display panel (Part to be provided at your site) Multiple remote controller adapter (PAC-SA88HA) Remote display panel (Part to be provided at your site) 0

51 System Name System iagram Features. Timer operation Enables control of start and stop. * For control by external timer, refer to Remote/ handheld combined control operation". Weekly timer: In addition to /OFF, up to eight temperature patterns can be set for each day of the week. * Only one timer can be selected; the auto off, simple and weekly timers cannot be combined. Simple timer: Start and stop operations can each be performed once within hours (can be set in -hour increments). Auto off timer: Operation is stopped when the preset time elapses following the start of operation. The time can be set from 0 minutes to hours in 0-minute increments. * Only one timer can be selected; the simple and auto off timers cannot be combined. Parts Required in Addition to Standard System Components (Indoor/Outdoor Units, Remote Controller) MA Remote controller (PAR-MAA) H.Interlock operation with peripheral equipment Enables control of Mitsubishi Lossnay ventilator by remote controller. Lossnay ventilator Indoor unit Remote Controller Connecting a Lossnay ventilator and an indoor unit enables control of interlock/solo ventilation operation and airflow. (Only the microcomputer type Lossnay ventilator can be used.) I.Rotation Main Remote Controller Sub Indoor unit Outdoor unit When abnormality occurs while operating, it changes into operating the back up unit, and operating is continued. (Unit function Mode No. 0 setting No., Indoor controller board SW-- ) Main / Sub setting Main : Indoor controller board SW- : OFF Sub : Indoor controller board SW- : Each system operates alternately for hours or 8 hours. (Unit function Mode No. 0 setting No.: hours/ No. : 8 hours, Indoor controller board SW - ) Main / Sub setting Main : Indoor controller board SW- : OFF Sub : Indoor controller board SW- : This system can correspond only by the pattern of two refrigerant group by : (indoor and outdoor unit combination) systems.

52 0-. E REMOTE CTROLLER (STANAR) OPERATI () One Wired Remote Controller (OC: Outdoor unit IC: Indoor unit R: Remote controller (for wireless type: receiver) Slim Air Conditioners System Standard : Simultaneous Twin Indoor controller board switch setting System diagram (Wired remote controller) Outdoor unit OC Indoor unit IC Wired remote controller R Indoor/Outdoor connection cable Remote controller cable OC IC- R OC IC- R IC- SW- OFF Indoor unit IC IC- (Main) IC- (Sub) (Reference) If simultaneous twin, connect the remote controller to an indoor unit. All functions of the indoor unit can control even if different models (different types) are mixed. Electrical wiring diagram Power source wiring Outdoor unit Indoor unit Remote controller OC (Polarity) IC LN (No polarity) R Power supply terminal block L, N Indoor/outdoor connection cable terminal block, (Polarity) Remote controller cable terminal block, (No polarity) Power source wiring () Wireless remote controller Slim Air Conditioners System Standard : Simultaneous Twin Indoor controller board switch setting System diagram Outdoor unit (Wireless remote OC controller receiver) Indoor unit IC Wireless remote controller receiver section R' Indoor/Outdoor connection cable Wireless remote controller cable OC IC- 9 R' Wireless remote controller cable OC IC- 9 R' IC- SW- OFF Indoor unit IC IC- (Main) IC- (Sub) (Reference) If simultaneous twin, connect the remote controller to an indoor unit. All functions of the indoor unit can control even if different models (different types) are mixed. Electrical wiring diagram Indoor unit IC Controller board CN90 Wireless remote controller receiver R CNB 9 Remote controller cable terminal block

53 0-. TWO-REMOTE CTROLLER OPERATI () Two Wired Remote Controllers (R: Wired remote controller) Slim Air Conditioner System Standard : Simultaneous Twin System diagram (wired remote controller) Outdoor unit OC Indoor unit IC Wired remote controller R Outdoor unit OC Indoor unit IC Wired remote controller R OC Indoor/outdoor connection cable Remote controller cable OC IC IC R- R- R- R- OC IC- IC- R- R- OC IC- IC- R- R- Indoor controller board switch setting SW- Indoor unit IC OFF IC- (Main) IC- (Sub) [Reference] In the case of free component multi type systems consisting of simultaneous twin units, connect the remote controllers to each indoor unit. All the functions of the connected indoor units can be controlled even if the system consists of different models. In the case of free component multi type systems consisting of simultaneous twin units, the indoor units should be connected by crossover wiring. Set one of the remote controllers as the main controller (factory setting) and the other as the sub controller using the remote controller's function selection. () Two Wireless Remote Controllers (R': Wireless remote controller receiver) Indoor controller board switch setting Slim Air Conditioner System Standard : Simultaneous Twin System diagram (wireless remote controller receiver) Outdoor unit OC Indoor unit IC Wireless remote controller receiver section R' OC Indoor/outdoor connection cable IC- IC- Receiver connection 9 9 cable R'- R'- Remote controller cable * Numbers given in ( ) apply when power is supplied to the indoor and outdoor units separately. [Reference] In the case of free component multi type systems consisting of simultaneous twin units, connect two wireless remote controller receivers (one each) to any two of the indoor units. All the functions of the connected indoor units can be controlled even if the system consists of different models. In the case of free component multi type systems consisting of simultaneous twin units, the indoor units should be connected by crossover wiring. In the case of "standard :" connection, it is not possible to connect two remote controller receivers to the indoor units. However, with systems consisting of simultaneous twin units, it is possible to connect a remote controller receiver to two indoor units. In this case, all the pair numbers will be "0" (factory setting, no change necessary), and all the units will be turned /OFF simultaneously. When using two or more wireless remote controllers, the display contents on the remote controllers may differ from the actual settings, since the operation made last by any of the remote controllers will be effective. () One Wired and One Wireless Remote Controller (R: Wired remote controller, R': Wireless remote controller receiver) Slim Air Conditioner System Standard : Simultaneous Twin System diagram (wired remote controller and wireless remote controller receiver) Outdoor unit OC Indoor unit IC Wired remote controller R Receiver R' OC Indoor/outdoor connection cable Remote controller cable IC R 9 Receiver connection cable R' OC IC- R IC- 9 [Reference] In the case of free component multi type systems consisting of simultaneous twin units, connect both the wired remote controller and wireless remote controller receiver to any one of the indoor units. All the functions of the connected indoor units can be controlled even if the system consists of different models. In the case of free component multi type systems consisting of simultaneous twin units, the indoor units should be connected by crossover wiring. When using two or more wireless remote controllers, the display contents on the remote controllers may differ from the actual settings, since the operation made last by any of the wireless remote controllers will be effective. R' SW- OFF Indoor unit IC IC- (Main) IC- (Sub) Indoor controller board switch setting SW- OFF Indoor unit IC IC- (Main) IC- (Sub)

54 0-. ROUP CTROL OPERATI (COLLECTIVE OPERATI AN CTROL OF MULTIPLE REFRIERANT SYSTEMS ( to )) roup control can be operated by using MAC-9IF-E. The setting of wired remote controller is subjected to variation according to the function of the indoor unit. (for mode operation, setting temperature, fan step, air direction) The display of remote controller and operating the indoor unit might be different. Neither the test run nor the function setting can be done by MA remote controller connected with MAC-9IF-E..Connecting the MA& CTACT TERMINAL Interface to the Indoor Unit Connect the interface unit and the indoor control board using the connecting cable that came with the interface. Extending or shortening the connecting cable that comes out of the interface may cause it to malfunction. Also, keep the connecting cable as far as possible away from the electrical wires and ground wire. o not bundle them together. INOOR CN0 or CN9 Indoor control board Connect the connecting cable that comes with the interface unit to the connector CN0 or CN9 on the indoor control board..connecting the remote control interface with each system (For details on each system, see the relevant instruction manual.) Replace the interface unit mounting cord clamp with a supplied mounting cord clamp based on the thickness of the connecting cable used for each system. Mounting screws (black). o Interface unit mounting cord clamp or mounting cord clamps Connecting cable for each system The cables connected to the Indoor unit should be mounted on or near the Indoor unit. If the connecting cable is not securely mounted, the connector may detach, break, or malfunction. Mounting screws o 0 Mounting cord clamp Electrical wire mounting bracket Mounting screws o Mounting cord clamp Set the interface dip switch (SW00 0) settings before turning on the power. If the interface dip switch (SW00 0) settings are not set correctly, the system will not function properly.

55 Use as a Wired Remote Control (Using the MA Remote Controller) Note:. Be sure the Auto / isplay Setting on the MA remote controller is set to OFF before use. For information on how to set the Auto/ isplay Setting, see the MA remote controller instruction manual. The actual operating status of the unit may differ from what is shown on the remote controller display. A test run cannot be initiated using the test run switch on the MA remote controller... The horizontal vanes on the unit cannot be operated using the louver switch.. The range of room temperature indication is between 0: and 8:. Indoor unit ip switch settings SW00 does not have to be set. CN0 Interface unit A B TB80 Remote control cord that came with the MA remote controller (Non polarity) MA remote controller (PAR-MAA) * PAR-0MAA cannot be used with this interface. SW0: SW0- No. -: Refrigerant address Set this switch when multiple indoor units (and remote control interfaces) are connected to a single MA remote controller. Always start the refrigerant address at "0". Even when connecting multiple outdoor units, set a different refrigerant address for each indoor unit. Refrigerant address 0 Refrigerant address "0" Refrigerant address "" Refrigerant address "" Outdoor unit Outdoor unit Indoor unit Interface MA remote controller SW0- No. In case of connecting MAC-9IF-E to this model, No. should be set to OFF and No. should be set to..

56 SW0: Settings to accommodate MA remote controller and settings to accommodate outdoor units SW No. No. No. No. No. Functions OFF Comments Only specify these settings when connecting an Refrigerant address 0 MA remote controller. Refrigerant address Refrigerant address Refrigerant address Refrigerant address Refrigerant address Refrigerant address Refrigerant address Refrigerant address 8 Refrigerant address 9 Refrigerant address 0 Refrigerant address Refrigerant address Refrigerant address Refrigerant address Refrigerant address SW No. Functions OFF Comments No. Room temperature detector Indoor unit Remote control This should be set to OFF. No. The model of Mr. SLIM exists in the same group. Not mixed Mixed This should be set to.

57 SW0 : Air Conditioner Function Settings SW No. Functions No. only type/ Heat pump type No. No. No. Auto mode Fan speed OFF Heat pump type Not available (setting No. disabled) Available (unit) only type Available (setting No. enabled) Available (remote controller) speeds speeds (-speed model set ) Comments Set the mode in accordance with the operation manual for the indoor unit. Heat pump type : Set to. only type : Set to OFF. Set to OFF. When operating a -speed model with the -speed setting (), the MA remote controller display will indicate fan speeds. The table below shows the displays and the actual outputs at that time. isplay Meaning Indoor unit output Low speed Low speed Medium speed High speed High speed High speed No. No. No. Vane Swing Not in use Available Available Not available Not available The Vane function of either of indoor unit : When the function is provided, it is Available (OFF). When the function is not provided, it is Not available (). The Swing function of either of indoor unit : When the function is provided, it is Available (OFF). When the function is not provided, it is Not available (). Permanently set to OFF. No. 8 Fan mode Not available Available Set to. * Fan speed step model : An actual fan speed is step though the display of remote controller becomes step or step.. Test Run (Check Operations) Interface status monitor You can check the status of the interface by the LE lamp on the interface unit board. LE lamp no. Lamp off Lamp on Blinking LE C V is not being supplied from the air conditioner. C V is being supplied from the air conditioner. LE evice is not communicating properly with the air conditioner. Blinking at approx. second intervals: evice is communicating normally with the air conditioner. LE evice is not communicating properly with the MA remote controller. Blinking at approx. 8 second intervals: evice is communicating normally with the MA remote controller. * Use the table above to check the device operations.. Mounting the Remote Control Interface Unit The Interface unit should be placed in a location where the connecting cable from the interface can reach an indoor unit. The device will not function properly if the connecting cable is extended so the connecting cable should not be extended. Mount the interface unit securely to a pillar or wall using or more screws. When Using Wall Mounting Brackets Attach the wall mounting brackets to the interface unit using mounting screws. Mount the unit to a pillar or wall using mounting screws. Interface unit Wall mounting brackets Cord clamp for wiring Mounting screws Mounting screws Mounting screws

58 When Mounting irectly to a Wall Mount the interface unit case to the wall using the mounting screws. When mounting the interface unit inside a ceiling or wall, install an access door to facilitate maintenance. Interface case mounting screws When the interface unit is mounted above an indoor unit, it should be positioned 0 mm or more away from the unit to ensure that ceiling grills can be removed. Mounting screws * When mounting the interface unit using a cushioning material, be sure to mount it in a location where it will not fall. Interface unit 0 mm or more Attach the interface unit connecting cable here. Store extra connecting cable in the ductwork space behind the indoor unit. * If there is any slack in the connecting cable, use a fastener to keep it in place. Cushioning material 8

59 0-. POWER OUTAE AUTOMATIC RECOVERY OPERATI Whenever a power outage or switching of the power supply causes the power supply of an operating air conditioner to go from OFF to, this function will automatically restore the operation of the air conditioner to its previous operating mode. w If the power is turned from OFF to when the air conditioner is not in operation, the air conditioner will not automatically be turned on. However, the timer operation will be cancelled if the air conditioner is in timer operation (including when the unit is waiting for its start time). Setting for timer operation must be performed once again. If there is a momentary power outage of less than one second while the air conditioner is in operation, there may not be a clear determination of whether or not there was a power failure. When it has been determined that there has been a power failure, recovery will take approximately four minutes after the power is restored. Please wait. (Once "PLEASE WAIT" has appeared on the display, a protection system will operate to prevent the unit from restarting for three minutes.) When it has been determined that there has been no power failure, operation will continue as is. Settings can be made by function selections from the remote controller. When there is group control, selection of all refrigerants is required. 0-. INIVIUAL CTROL OPERATI FROM A SEPARATE ROOM By simply centralizing the remote controllers installed in each room in a separate control room, individual control or centralized monitoring of the air conditioners in each room can be attained. Air conditioner control can be performed up to a total of 00 meters away by connecting the indoor units and remote controllers with 0. to. mm -core cable. Indoor unit Indoor unit Indoor unit Remote controller Control room room room room If a remote controller is installed in a room and control room, refer to the section on operating with two remote controllers. 0-. COMBINE REMOTE/LOCAL CTROL Operation/remote controller prohibit/ stop can be controlled from a remote location by routing the remote stop/start adapter (PAC-SERA-E sold separately) through the relay box installed on site. When this remote control is cancelled, the local remote controller can be used for operating and stopping the air conditioner.. Basic system wiring Use the remote start/stop adapter (PAC-SERA-E) and connect the "Start/Stop Circuit From Remote Location" that comes from the relay box and remote/local selection switch and connect it to the CN connector on the printed circuit board for the indoor unit <Points of precaution> Match the rated power supply voltage of the remote/local selection switch and relay (X) with the power supply for the controller. When performing group control of multiple outdoor unit using a timer, be sure to arrange the timer so that all units do not start at the same time. If this is not performed, all of the units will start at one time creating an over current that will cause the circuit breaker to operate. An on-delay system is one that includes specifications for operating a limited time when an on signal is received and has a temporary off timer for recovery operations. Use a connecting relay when the wiring length exceeds 0 meters, such as when performing remote wiring. If this is not provided, abnormal operation will occur. () System diagram Control circuit power supply Relay box Relay box Relay box Indoor unit Indoor unit Indoor unit Indoor unit Remote controller Remote controller Remote controller Remote controller Remote/Local selection switch Control room W room room room W The AC for the control room is usually disconnected from the remote/local control system. 9

60 () Basic wiring diagram () Part specifications Control circuit power supply edicated short circuit prevention device Remote/Local selection switch SW SW No. unit relay box T No. unit relay box T To next unit Remote/Local selection switch (Example) Single polarity single-throw switch (V rating) Adapter for remote start/stop Model PAC-SERA-E (Sold separately) Relay box T Timer (On delay system) X Relay One method of easily distinguishing the on/off status of SW and SW is to use together with a "illuminated switch R" or pilot lamp. T Brown Red X X Orange X T X Brown Red Orange Remote control SW Remote/Local selection switch SW escription of functions Starting/stopping with remote controller disabled. AC is in operation. Starting/stopping by remote operation enabled. OFF Starting/stopping with remote controller disabled. Starting/stopping by remote operation enabled. OFF Starting/stopping with remote controller disabled. AC is in operation. Starting/stopping by remote operation enabled. OFF Starting/stopping with remote controller disabled. Starting/stopping by remote operation enabled. Note: When using group address, connect to refrigerant address "0" on the inside.. Examples of system applications In any of the following examples, there is a five to six second delay from the time the operating command is issued until the operation begins. This is when starting and stopping is performed by remote operation or external timer and when starting and stopping by the remote controller is to be prohibited. Indoor unit circuit board Orange SW Red Red CN Timer CN On site wiring Brown On site wiring Brown For remote operation For timer operation This is when starting and stopping is performed by remote operation or external timer and when starting and stopping by the remote controller is to be separated. Indoor unit Indoor unit Orange circuit board Orange circuit board SW Orange Red Brown On site wiring This is when permitting or prohibiting operation by remote controller is performed by external circuit. Indoor unit circuit board Orange This is not used. Protect exposed wire by wrapping with insulating tape Indoor unit circuit board CN SW On site wiring Red Brown CN Orange Indoor unit circuit board SW Red Red Timer SW CN SW CN On site wiring Brown Brown On site wiring For remote operation This is when starting and stopping is performed by remote operation and then allowing starting or stopping by remote control at any time. Use momentary switch for SW. (Manual operation/automatic recover switch on time is more than one second.) Press SW (on time is more than one second) and operation starts. After this has been done, stopping or restarting can be down by remote controller. If SW is on, operation by remote controller cannot be performed. If SW is off, operation by remote controller is permitted. 0

61 0-8. OBTAININ REMOTE ISPLAY The model of a wireless type can not correspond. Use the remote operation adapter (PAC-SF0RM-E) to provide operation/error non-voltage contact output and on/off input function. () Wiring method Wireless CN90 CN TB External input TB Error External input No voltage (Momentary "a" contact) Error output (No voltage momentary "a" contact) HA CN TB Operation Operating output (No voltage momentary "a" contact) Indoor control circuit board Remote operation adapter TB is a dedicated terminal for contact point input. Never input voltage. It will damage.caution the indoor control circuit board. <Connections on the indoor unit side> When using external output function Insert the 9-prong connector (-core) of the attached cable to CN90 on the indoor control circuit board. When using the external input function Insert the -prong connector (-core) of the attached cable to CN on the indoor control circuit board. W The connector is direction-sensitive. Use care not to make an error when inserting. Never force the connectors. This will result in damage. () Locally procured parts Item Name Model and specifications External output function External output signal wire Use sheathed vinyl coated cord or cable. Wire type: CV, CVS or equivalent. Wire size: Stranded wire 0.mm to.mm Single straged: {0.mm to.mm isplay lamp, etc. No voltage a contact AC00V (C0V), A or less External input function External input signal wire Use sheathed vinyl coated cord or cable. Wire type: CV, CVS or equivalent. Wire size: Stranded wire 0.mm to.mm Single straged: {0.mm to.mm Switch No voltage a contact (Start and stop operation is switched by inputting a pulse of 00ms or more) 0-9. TIMER OPERATI Timer operation can be performed by setting the wired or wireless remote controller timer. Start and stop times can be set in 0-minute increments within a -hour period. When used in combination with the central control remote controller of the M-NET control system for the outdoor unit, one program timer can be used for individual timer settings for each group of the central control system. (Each timer setting can be stored in data memory so timer settings for up to 0 groups can be set individually.) W Please refer to the MELANS catalog or technical information for details about the central control remote controller. Operating with on-site timer () Summary of system If the Remote /OFF adapter (PAC- SERA-E) (sold separately) is used, the on-site timer can be operated to turn each unit on and off. Power supply for controller Timer control panel (on-site) Indoor unit Remote controller Indoor unit Remote controller Indoor unit Remote controller

62 () Basic pattern for timer control Use a no-voltage contact point output timer (one that has separate circuits for the load side and timer power supply). a) Timer-independent control b) Combined control by timer and remote controller As selected by remote controller operation switch. Orange From indoor unit Red Brown T () Basic system Refer to 0-. COMBINE REMOTE/LOCAL CTROL. SW SW OFF From indoor unit Timer control Remote controller control Orange T Red Brown SW 0-0. LINKE OPERATI WITH PERIPHERAL AIR CITIERS EQUIPMENT Lossnay operation Linked operation with a Lossnay unit can be obtained by connecting Lossnay linkage cable (Model PAC-SB8VS - sold separately) to the CNL (Remote kit) on the circuit board of the indoor unit. This function must be selected from the remote controller. Summary of wiring Connect the Lossnay linkage cable (Model PAC- SB8VS) connector to CNL on the indoor unit on the circuit board of the indoor unit. Connect the lead wire of the Lossnay linkage cable to the Lossnay external control input terminal blocks () and () (At this time, the input terminal blocks () and () have no polarity.) Wiring diagram Control circuit board Connector (CNL) Slim indoor unit Lossnay linkage (PAC-SB8VS) Lossnay External control input terminal block Precautions when wiring The Lossnay linkage cable can be extended up to a maximum of 00 meters. When extending the Lossnay linkage cable, be sure to connect securely and take proper steps to ensure insulation. (Extension cable specifications: Sheathed vinyl cord or cable 0. to 0.mm ) Lossnay linked cable Arrange wiring so that there can be no contact between the Lossnay linkage cable and the power supply cord. Contact may cause malfunctioning. (Separate by cm or more.) 0-. OBTAININ HUMIIFIER SINAL The humidifier signal that is linked to the AC heating operation (indoor unit ventilator) can be obtained by connecting the adapter for the humidifier signal to connector CN on the printed circuit for the indoor unit and wiring it to the humidifier unit via the on-site relay box. There is no output when the thermostat is off, during heating preparation and during defrosting. Humidifier unit Basic wiring X: Relay (CV) CN (Indoor unit circuit board) W Please consult your nearest Mitsubishi Electric representative for information about obtaining the adapter for humidifier signal. System example Humidifier unit Indoor unit Remote controller Relay box (On-site tinstallation) Relay box (On-site tinstallation) Remote controller 0-. EXTERNAL MOUNTIN OF TEMPERATURE SENSOR Temperature control from an alternative external location can be performed by connecting the temperature sensor (Model PAC-SETS-E - sold separately) to the CN0 connector on the circuit board for the indoor unit. The wired remote controller also has an internal temperature sensor. Function selection from the remote controller is required. Refer to FUNCTI SETTIN for information of installation manual about selecting functions with the remote controller.

63 0-. MULTIPLE REMOTE CTROL ISPLAY You can control several units with a multiple remote control display, by wiring an optional multiple remote controller adapter (PAC-SA88HA-E) with relays and lamps on the market. How to wire () Connect the multiple remote controller adapter to the connector CN on the indoor controller board. () Wire three of the five wires from the multiple remote controller adapter as shown in the figure below. <Wiring > CN on indoor controller board connector(p) RE BROWN REEN YELLOW ORANE Optional multiple remote controller adapter The maximum distance between indoor board and relay is 0m. X X Electrical insulation is needed. Wiring at the actual place X X L RL Power supply Refer to 8--. Indoor controller board. [Notes on Signs] X:Relay (for operation lamp) X:Relay (for check lamp) RL:Operation Lamp L:Check Lamp [Field supplied parts] Relays:V C with rated coil power consumption below 0.9W. Lamps:Matching to power supply voltage. <System> Power supply wires wires wires wires No. unit No. unit No. unit Muitiple remote control -OFF display (Field supply) (Operation check) <Wiring diagram> Power supply Remote controller RL- L- RL- L- RL- L- Multiple Remote Control isplay Remote controller cable Remote controller Relay box (Field supply) Whenever the indoor unit is operating, the duct fan operates. ()Connect the optional multiple remote controller adapter(pac-sa88ha-e)to the connector CN on the indoor controller board. ()rive the relay after connecting the V C relay between the Yellow and Orange connector lines. Use a relay under W. MB: Electromagnetic switch power relay for duct fan. X: Auxiliary relay (V C LY-F) Remote controller X- X- X- X- X- X- X- X- X- X- X- X- Relay box reen Connector (P) Multiple remote controller adapter No. unit No. unit No. unit connect to the connector CN 0-. INTERLOCKIN OPERATI METHO WITH UCT FAN (Booster fan) ~ CN on indoor controller board Red Brown Be sure to secure insulation material by tape and such Yellow Orange Indoor unit side Multiple remote controller adapter PAC-SA88HA-E Installation at site MB Be sure to secure insulation material by tape and such

64 ISASSEMBLY PROCEURE INOOR UNIT PCH-AKH OPERATIN PROCEURE. Removing the air intake grill () Slide the intake grill holding knobs (at two locations) backward to open the intake grill. () When the intake grill left open, push the stoppers on the rear hinges (at two locations) to pull out the intake grill. Figure PHOTOS&ILLUSTRATI intake grill intake grill hoiding knobs slide shinges Pull out the intake grill. Removing the electrical box () Remove the air intake grill. () Remove the screw from the beam and remove the beam. () Remove the screws from the electrical cover, and remove the electrical cover. () isconnectors including CNV and CN. () Remove the screws from the electrical box and pull out the electrical box. <Electrical parts in the electrical box> Terminal block (for power supply) Terminal block (for in/outdoor connecting wire) Terminal block (for remote controller) Fan motor capacitor Indoor control board Power board Figure Screws(electrical cover) Slide to the left electrical cover screws(electrical box) Photo beam clamp Fan motor capacitor Power board Indoor control board Terminal block (power supply) Terminal block Terminal block (remote control) (in/out connecting)

65 OPERATIN PROCEURE PHOTOS&ILLUSTRATI. Removing the fan motor () Remove the air intake grill. () Remove the screw for removing the motor support at both left and right side. () Loosen the set screws at the fan motor side of the connecting joint. () Slide the fan motor to the left side and pull it out. Photo Screws Motor set screws Motor support connecting joint. Removing the sirocco fan () Remove the air intake grill. () Remove beam. () Remove the lower casing while pressing the stoppers at upper side of the casing. () Loosen the set screws at the connecting joint. () Remove the sirocco fan and shaft together by sliding the shaft to the left. Photo Motor Set screw Catch Casing (Note) Make sure that the upper side casing is snapped to the fan plate securely with catch. Connecting joint Sirocco fan Shaft Bearing Screws. Removing the side panel (right or left) () Remove the air intake grill. () Remove the screw from the side panel, and remove the side panel by sliding the panel to the front. Figure side panel Sliding the pare to the front screw

66 OPERATIN PROCEURE PHOTOS&ILLUSTRATI. Removing the vane motor () Remove the air intake grill. () Remove the left side panel. () Remove the relay connector of vane motor. () Remove the electrical box. () Remove the screws of vane motor, then remove vane motor. (Note) Connect the lead wires and connectors properly and place them in the proper position so that the wires are not pinched by other parts. Photo Screw Check panel Relay connector of the pipe thermistor Left side panel Photo Hold indoor coil thermistor Trap. Removing the indoor coil thermistor () Remove the air intake grill. () Remove the right side panel. () Remove the relay connector of the indoor coil thermistor. () Remove the screw, and remove the check panel. () Extract the indoor coil thermistor from the holder. <Caution for the installation> There is a possibility for the short circuit when connector gets wet by water through the thermistor lead wire. Therefore, lead wire of the pipe thermistor should be trapped as shown in the picture. Photo Relay connector of the vane motor Screws Vane motor. Removing the Under panel () Remove the air intake grill. () Remove the beam. () Remove the side panel (right and left). () Unscrew the screws of the under panel, then remove the under panel. w Weight of the under panel : approx. kg. Photo Screws Under panel

67 OPERATIN PROCEURE 9. Removing the drain pump (option) () Remove the air intake grill. () Remove the beam. () Remove the side panel (right and left). () Remove the under panel. Remove the screws of the right and left side drain pan. () Remove the insulation in center of the drain pan, and after removing the screw, remove the drain pan. Photo 8 PHOTOS&ILLUSTRATI (Note) Please aware that there might be drain left in the drain pan when you remove the drain pump. Screw rain pan Screw (Insulation) Screw 0. Removing the guide vane () Remove the intake grill. () Remove the beam. () Remove the side panel (right and left). () Remove the under panel. () Remove the drain pan. () Remove the screw from the guide vane, then remove the guide vane. Photo 9 rain pan uide vane Screw. Removing the Auto vane () Remove the intake grill. () Remove the left side panel. () Remove the left side box. () Remove the under panel. () Remove the screw from the auto vane. () Slide the auto vane to the right side and pull the auto vane out. Photo 0 Auto vane Screw

68 OPERATIN PROCEURE PHOTOS&ILLUSTRATI. Removing the electric heater. () Remove the air intake grille. (See the figure ) () Remove the beam. () Remove the electrical box cover and disconnect the connector (P red) of the heater. () Loosen clamps for the heater lead wires. () Remove the side panels (right and left). (See the figure ) () Remove the under panel. (See the photo ) () Remove the drain pan. (See the photo 8) (8) Remove the screws from the service panel. (9) Pull out the heater with the service panel. Photo Screws Clamp Connector (heater) Service panel Electrical box. Removing the heat exchanger. () Remove the air intake grille. (See the figure ) () Remove the beam. () Remove the panels (right and left). (See the figure ) () isconnect the relay connector of the pipe thermistor. () Remove the under panel. (See the photo ) () Remove the drain pan. (See the photo 8) () Unscrew the screw of the pipe cover, and remove the pipe cover. (8) Unscrew the screw of the pipe support, and remove the pipe support. (9) Unscrew the screw of the heat exchanger, and remove the heat exchanger. Remove the heat exchanger with care. Since this is quite heavy, removing work should be done with more than people. wweight of heat exchanger : approx..kg Photo Pipe support Screws Pipe cover Screws Heat exchanger 8

69 PARTS LIST FAN AN HEATER PARTS PCH-AKH PCH-AK Q'ty / set No. Parts No. Parts Name Specifications PCH AKH AK R0 J 0 MOTOR LE Remarks (rawing No.) Wiring Recommended iagram Symbol Q'ty Price Unit Amount TW B0 0 CASIN R0 E SIROCCO FAN R0 E 0 ROOM TEMPERATURE THERMISTOR TH R0 E PIECE (MOTOR) R0 J 0 FAN MOTOR 09BPMS MF R0 J RAIN PLU 8 R0 A 9 RAIN PAN ASSY 9 R0 K 00 THERMAL SWITCH OFF:0: :: H 0 R0 8J 0 R0 0J 0 INSULATOR INSULATOR TW J 00 HEATER ELEMENT 80V W H R0 J 0 PIPE TEMPERATURE THERMISTOR TH TW H 80 HEAT EXCHANER R0 P0 0 THERMAL FUSE 0V 98: 0A FS, 9

70 FAN AN HEATER PARTS PCH-.AKH, PCH-.AK PCH-AKH, PCH-AK Q'ty / set No. Parts No. Parts Name Specifications PCH.. AKH AK R0 9J 0 MOTOR LE Remarks (rawing No.) Wiring Recommended iagram Symbol Q'ty Price Unit Amount TW 0J FAN MOTOR O9CP0MS MF R0 00 SHAFT JOINT R0 E PIECE (MOTOR) R0 E SIROCCO FAN R0 E 0 ROOM TEMPERATURE THERMISTOR TH R0 9J 00 SHAFT (FAN) 8 R0 E00 0 SLEEVE BEARIN 9 R0 9J BEARIN SUPPORT 0 R0 J RAIN PLU R0 A 9 RAIN PAN ASSY TW B0 0 CASIN R0 E SIROCCO FAN R0 0J 0 R0 0J 0 INSULATOR INSULATOR TW 0J 00 HEATER ELEMENT 80V 00W H R0 J 0 PIPE TEMPERATURE THERMISTOR TH R0 9J 80 R0 J 80 HEAT EXCHANER HEAT EXCHANER 8 TW J 0 THERMAL FUSE 0: A 0V FS, 9 R0 K 00 THERMAL SWITCH OFF:0: :: H 0

71 FAN AN HEATER PARTS PCH-AKH PCH-AK Q'ty / set No. Parts No. Parts Name Specifications PCH- AKH AK R0 E PIECE (MOTOR) Remarks (rawing No.) Wiring Recommended iagram Symbol Q'ty Price Unit Amount R0 J 0 MOTOR LE R0 J 0 FAN MOTOR 0BP90MS MF R0 00 SHAFT JOINT R0 E9 SIROCCO FAN R0 E 0 ROOM TEMPERATURE THERMISTOR TH R0 9J 00 SHAFT 8 R0 E00 0 SLEEVE BEARIN 9 R0 J BEARIN SUPPORT 0 R0 J RAIN PLU R0 A 9 RAIN PAN ASSY TW B0 0 CASIN R0 E0 SIROCCO FAN R0 0J 0 R0 J 0 INSULATOR INSULATOR TW 9J 00 HEATER ELEMENT 80V 900W H R0 J 0 PIPE TEMPERATURE THERMISTOR TH R0 J 80 HEAT EXCHANER 8 TW 89 0 THERMAL FUSE : A 0V FS, 9 R0 K 00 THERMAL SWITCH OFF:0: :: H

72 FAN AN HEATER PARTS PCH-AKH, PCH-AK PCH-AKH, PCH-AK No. Parts No. Parts Name Specifications R0 9J 00 SHAFT Q'ty / set PCH AKH AK Remarks (rawing No.) Wiring Recommended iagram Symbol Q'ty Price Unit Amount R0 J 0 MOTOR LE R0 J 0 FAN MOTOR 0BP0MS MF R0 E PIECE (MOTOR) R0 E8 SIROCCO FAN R0 E 0 ROOM TEMPERATURE THERMISTOR TH R0 E9 SIROCCO FAN 8 R0 00 SHAFT JOINT 9 R0 A 9 RAIN PAN ASSY 0 R0 E0 SIROCCO FAN R0 J RAIN PLU TW B0 0 CASIN R0 E00 0 SLEEVE BEARIN R0 J BEARIN SUPPORT R0 0J 0 R0 J 0 INSULATOR INSULATOR TW J 00 HEATER ELEMENT 80V 000W H R0 J 0 PIPE TEMPERATURE THERMISTOR TH 8 R0 J 80 TW H 80 HEAT EXCHANER HEAT EXCHANER 9 TW J 0 THERMAL FUSE 0: A 0V FS, 0 R0 K 00 THERMAL SWITCH OFF:0: :: H

73 STRUCTURAL PART PCH-AK PCH-AKH Part numbers that are circled are not shown in the figure. Q, ty/set No. Parts No. Parts Name Specifications PCH-AK PCH-AKH R0 N S.PLATE-L R0 A 00 L.L FILTER R0 J 0 RILLE HINE R0 8J 9 RILLE ASSY R0 J 9 RILLE ASSY R0 J 0 RILLE CATCH R0 A 00 L.L FILTER 8 REAR SUPPORT 9 R0 J 9 UNER PANEL 0 BEAM(A) TW E0 00 W.BOAR CASE R0 8J S.PLATE-R R0 J 808 RIHT LE (R) R0 J 8 SERVICE PANEL R0 J RIHT SIE PANEL R0 J 0 RIHT SIE BOX R0 J 08.V ASSY-R 8 R0 J FRT PANEL 9 R0 J 00 AUTO VANE 0 R0 J 08.V ASSY-L R0 A REAR PANEL R0 J 08 LEFT SIE BOX R0 E0 VANE MOTOR R0 J 809 LEFT LE (L) R0 J LEFT SIE PANEL R0 J JOINT SOCKET TW E00 0 RAIN HOSE COVER Remarks (rawing No.) (B0HK0) (BHH08) Wiring Recommended Price iagram Symbol Q'ty Unit Amount MV

74 STRUCTURAL PART PCH-.AK PCH-AK PCH-AK PCH-.AKH PCH-AKH PCH-AKH Part numbers that are circled are not show in the figure. No. Parts No. Parts Name Specifications R0 J R0 J R0 J 809 R0 N R0 J R0 A R0 A R0 J 0 R0 J 0 R0 J 9 R0 A 00 R0 9J 9 TW E0 00 R0 8J R0 J R0 J R0 J R0 J 808 R0 J 8 R0 8J 8 R0 J 0 R0 J 0 R0 9J R0 J R0 9J 00 R0 J 00 R0 J 08 R0 J 08 R0 J 08 R0 J 08 R0 E00 08 R0 9J R0 J R0 J TW E00 0 LEFT SIE PANEL LEFT SIE PANEL LEFT LE S.PLATE-L S.PLATE-L REAR PANEL REAR PANEL RILLE HINE RILLE CATCH RILLE ASSY L.L FILTER UNER PANEL W.BOAR CASE REAR SUPPORT BEAM (A) S.PLATE-R S.PLATE-R RIHT SIE PANEL RIHT SIE PANEL RIHT LE SERVICE PANEL SERVICE PANEL RIHT SIE BOX RIHT SIE BOX FRT PANEL FRT PANEL AUTO VANE AUTO VANE.V ASSY-R.V ASSY-C.V ASSY-L LEFT SIE BOX LEFT SIE BOX VANE MOTOR VANE MOTOR JOINT SOCKET RAIN HOSE COVER Q, ty/set PCH., AK, AKH Remarks (rawing No.) (B0HK0) (BHH08) Wiring Recommended Price iagram Symbol Q'ty Unit Amount MV MV

75 STRUCTURAL PART PCH-AK PCH-AK PCH-AKH PCH-AKH Part number that are circled are not shown in the figure. No. Parts No. Parts Name Specifications R0 J R0 J R0 A R0 A 00 R0 J 0 R0 8J 9 R0 J 0 R0 J 9 R0 A 00 R0 J 9 TW E0 00 R0 J R0 J 808 R0 8J 8 R0 J 0 R0 J R0 J R0 J 00 R0 J 08 R0 J 08 R0 J 08 R0 E00 08 R0 J R0 J 809 R0 J TW E00 0 LEFT SIE PANEL S.PLATE-L REAR PANEL L.L FILTER RILLE HINE RILLE ASSY RILLE CATCH RILLE ASSY L.L FILTER UNER PANEL W.BOAR CASE REAR SUPPORT BEAM(A) RIHT SIE PANEL RIHT LE SERVICE PANEL RIHT SIE BOX S.PLATE-R FRT PANEL AUTO VANE.V ASSY-R.V ASSY-C.V ASSY-L LEFT SIE BOX VANE MOTOR LEFT LE JOINT SOCKET RAIN HOSE COVER Q, ty/set PCH-, AK PCH-, AKH Remarks (rawing No.) (B0HK0) (BHH08) Wiring Recommended Price iagram Symbol Q'ty Unit Amount MV

76 ELECTRICAL PARTS PCH-AK PCH-.AK PCH-AK PCH-AK PCH-AK PCH-AK 8 TEMP. /OFF 9 0 No. Parts No. Parts Name Specifications R0 0L CAPACITOR = 0V Q'ty / set PCH.,, AK Remarks (rawing No.) Wiring iagram Symbol C Recommended Q'ty Unit Price Amount TW 9J CAPACITOR = 0V C R0 A CAPACITOR = 0V C R0 E0 9 FUSE 0V.A FUSE TW E 0 INOOR CTROLLER BOAR I.B TW A TERMINAL BLOCK P (L,N, ) TB TW E TERMINAL BLOCK P (,,) TB TW TERMINAL BLOCK P (,) TB CTROL BOX (B00N00) 8 TW E POWER BOAR CTROL COVER (B0A808) P.B 9 CTROL COVER (B0A809) CTROL COVER (B0A800) 0 TW E0 0 REMOTE CTROLLER COR 0m TW E08 REMOTE CTROLLER PAR-MAA R.B

77 ELECTRICAL PARTS PCH-AKH PCH-.AKH PCH-AKH PCH-AKH PCH-AKH PCH-AKH 9 8 TEMP. /OFF 0 No. Parts No. Parts Name Specifications R0 0L CAPACITOR = 0V Q'ty / set PCH.,, AKH Remarks (rawing No.) Wiring iagram Symbol C Recommended Q'ty Unit Price Amount TW 9J CAPACITOR = 0V C R0 A CAPACITOR = 0V C R0 E0 9 FUSE 0V.A FUSE TW E 0 INOOR CTROLLER BOAR I.B TW A TERMINAL BLOCK P (L,N, ) TB TW E TERMINAL BLOCK P (,,) TB TW TERMINAL BLOCK P (,) TB CTROL BOX (B00N0) 8 TW E POWER BOAR P.B 9 R0 RELAY CTROL COVER JC-A CV (B0A808) 88H 0 CTROL COVER (B0A809) CTROL COVER (B0A800) TW E0 0 REMOTE CTROLLER COR 0m TW E08 REMOTE CTROLLER PAR-MAA R.B

78 RoHS PARTS LIST FAN AN HEATER PARTS PCH-AKH PCH-AK RoHS Q'ty / set No. Parts No. Parts Name Specifications PCH AKH AK 8 9 R0 J 0 R0 8J 0 R0 E R0 H08 0 R0 E R0 8J 0 R0 8J R0 E 9 R0 E 00 MOTOR LE CASIN SIROCCO FAN ROOM TEMPERATURE THERMISTOR PIECE (MOTOR) FAN MOTOR RAIN PLU RAIN PAN ASSY THERMAL SWITCH 09BPMS OFF:0: :: 0 R0 J 0 INSULATOR R0 J 0 INSULATOR TW E 00 HEATER ELEMENT 80V W R0 H0 0 TW H 80 PIPE TEMPERATURE THERMISTOR HEAT EXCHANER R0 P0 0 THERMAL FUSE 0V 98: 0A Remarks (rawing No.) Wiring iagram Symbol TH MF H H TH FS, Recommended Q'ty Price Unit Amount 8

79 FAN AN HEATER PARTS PCH-.AKH, PCH-.AK PCH-AKH, PCH-AK RoHS Q'ty / set No. Parts No. Parts Name Specifications PCH.. AKH AK R0 0J 0 MOTOR LE TW 0J R0 800 R0 E R0 E R0 H08 0 R0 0J 00 R0 E0 0 R0 0J R0 8J R0 A8 9 R0 8J 0 R0 E FAN MOTOR SHAFT JOINT PIECE (MOTOR) SIROCCO FAN ROOM TEMPERATURE THERMISTOR SHAFT (FAN) SLEEVE BEARIN BEARIN SUPPORT RAIN PLU RAIN PAN ASSY CASIN SIROCCO FAN O9CP0MS R0 J 0 INSULATOR R0 0J 0 INSULATOR TW E 00 HEATER ELEMENT 80V 00W R0 H0 0 PIPE TEMPERATURE THERMISTOR R0 0J 80 HEAT EXCHANER R0 J 80 HEAT EXCHANER 8 9 TW J 0 R0 E 00 THERMAL FUSE THERMAL SWITCH 0: A 0V OFF:0: :: Wiring Remarks Recommended iagram (rawing No.) Symbol Q'ty MF TH H TH FS, H Price Unit Amount 9

80 FAN AN HEATER PARTS PCH-AKH PCH-AK RoHS Q'ty / set No. Parts No. Parts Name Specifications PCH R0 E R0 J 0 R0 9J 0 R0 800 R0 E9 R0 E8 0 R0 0J 00 R0 E0 0 R0 J R0 8J R0 E8 9 R0 9J 0 R0 E0 R0 J 0 R0 J 0 TW E 00 R0 H0 0 R0 J 80 TW 0 R0 E 00 PIECE (MOTOR) MOTOR LE FAN MOTOR SHAFT JOINT SIROCCO FAN ROOM TEMPERATURE THERMISTOR SHAFT SLEEVE BEARIN BEARIN SUPPORT RAIN PLU RAIN PAN ASSY CASIN SIROCCO FAN INSULATOR INSULATOR HEATER ELEMENT PIPE TEMPERATURE THERMISTOR HEAT EXCHANER THERMAL FUSE THERMAL SWITCH 0BP90MS 80V 900W : A 0V OFF:0: :: AKH AK Wiring Remarks Recommended iagram (rawing No.) Symbol Q'ty MF TH H TH FS, H Price Unit Amount 80

81 FAN AN HEATER PARTS PCH-AKH, PCH-AK PCH-AKH, PCH-AK RoHS No. Parts No. Parts Name Specifications R0 0J 00 SHAFT Q'ty / set PCH AKH AK Remarks (rawing No.) Wiring iagram Symbol Recommended Q'ty Price Unit Amount R0 J 0 MOTOR LE R0 0J 0 FAN MOTOR 0BP0MS MF R0 E PIECE (MOTOR) R0 E8 SIROCCO FAN R0 H08 0 ROOM TEMPERATURE THERMISTOR TH R0 E9 SIROCCO FAN 8 R0 800 SHAFT JOINT 9 R0 E9 9 RAIN PAN ASSY 0 R0 E0 SIROCCO FAN R0 8J RAIN PLU R0 9J 0 CASIN R0 E0 0 SLEEVE BEARIN R0 9J BEARIN SUPPORT R0 J 0 R0 J 0 INSULATOR INSULATOR TW E 00 HEATER ELEMENT 80V 000W H R0 H0 0 PIPE TEMPERATURE THERMISTOR TH 8 R0 J 80 TW H 80 HEAT EXCHANER HEAT EXCHANER 9 TW J 0 THERMAL FUSE 0: A 0V FS, 0 R0 E 00 THERMAL SWITCH OFF:0: :: H 8

82 STRUCTURAL PART PCH-AK PCH-AKH Part numbers that are circled are not shown in the figure Q, ty/set No. Parts No. Parts Name Specifications PCH-AK PCH-AKH R0 N S.PLATE-L R0 A 00 L.L FILTER R0 J 0 RILLE HINE R0 8J 9 RILLE ASSY R0 J 9 RILLE ASSY R0 J 0 RILLE CATCH R0 A 00 L.L FILTER 8 REAR SUPPORT 9 R0 J 9 UNER PANEL 0 BEAM(A) TW E0 00 W.BOAR CASE R0 8J S.PLATE-R R0 J 808 RIHT LE (R) R0 J 8 SERVICE PANEL R0 J RIHT SIE PANEL R0 J 0 RIHT SIE BOX R0 J 08.V ASSY-R 8 R0 J FRT PANEL 9 R0 J 00 AUTO VANE 0 R0 J 08.V ASSY-L R0 A REAR PANEL R0 J 08 LEFT SIE BOX R0 E0 VANE MOTOR R0 J 809 LEFT LE (L) R0 J LEFT SIE PANEL R0 J JOINT SOCKET TW E00 0 RAIN HOSE COVER RoHS Remarks (rawing No.) (B0HK0) (BHH08) Wiring Recommended Price iagram Symbol Q'ty Unit Amount MV 8

83 STRUCTURAL PART PCH-.AK PCH-AK PCH-AK PCH-.AKH PCH-AKH PCH-AKH Part numbers that are circled are not show in the figure No. Parts No. Parts Name Specifications Q, ty/set Wiring Recommended Price PCH Remarks., iagram (rawing No.) Symbol Q'ty Unit Amount AK, AKH (B0HK0) (BHH08) RoHS R0 8J R0 J R0 8J 809 R0 E00 R0 E0 R0 0J R0 A R0 8J 0 R0 9J 0 R0 9J 9 R0 A9 00 R0 0J 9 TW E0 00 R0 9J R0 J R0 8J R0 J R0 8J 808 R0 9J 8 R0 0J 8 R0 8J 0 R0 J 0 R0 0J R0 8J R0 0J 00 R0 E 00 R0 8J 08 R0 8J 08 R0 8J 08 R0 8J 08 R0 E0 08 R0 E0 R0 E R0 8J TW E0 0 LEFT SIE PANEL LEFT SIE PANEL LEFT LE S.PLATE-L S.PLATE-L REAR PANEL REAR PANEL RILLE HINE RILLE CATCH RILLE ASSY L.L FILTER UNER PANEL W.BOAR CASE REAR SUPPORT BEAM (A) S.PLATE-R S.PLATE-R RIHT SIE PANEL RIHT SIE PANEL RIHT LE SERVICE PANEL SERVICE PANEL RIHT SIE BOX RIHT SIE BOX FRT PANEL FRT PANEL AUTO VANE AUTO VANE.V ASSY-R.V ASSY-C.V ASSY-L LEFT SIE BOX LEFT SIE BOX VANE MOTOR VANE MOTOR JOINT SOCKET RAIN HOSE COVER MV MV 8

84 STRUCTURAL PART PCH-AK PCH-AK PCH-AKH PCH-AKH Part numbers that are circled are not shown in the figure. RoHS No. Parts No. Parts Name Specifications R0 J R0 E0 R0 A9 R0 A0 00 R0 8J 0 R0 0J 9 R0 9J 0 R0 9J 9 R0 A9 00 R0 J 9 TW E0 00 R0 J R0 8J 808 R0 0J 8 R0 J 0 R0 J R0 9J R0 E 00 R0 9J 08 R0 9J 08 R0 9J 08 R0 E0 08 R0 E R0 8J 809 R0 8J TW E0 0 LEFT SIE PANEL S.PLATE-L REAR PANEL L.L FILTER RILLE HINE RILLE ASSY RILLE CATCH RILLE ASSY L.L FILTER UNER PANEL W.BOAR CASE REAR SUPPORT BEAM(A) RIHT SIE PANEL RIHT LE SERVICE PANEL RIHT SIE BOX S.PLATE-R FRT PANEL AUTO VANE.V ASSY-R.V ASSY-C.V ASSY-L LEFT SIE BOX VANE MOTOR LEFT LE JOINT SOCKET RAIN HOSE COVER Q, ty/set PCH-, AK PCH-, AKH Remarks (rawing No.) (B0HK0) (BHH08) Wiring Recommended Price iagram Symbol Q'ty Unit Amount MV 8

85 ELECTRICAL PARTS PCH-AK PCH-.AK PCH-AK PCH-AK PCH-AK PCH-AK 8 TEMP. /OFF 9 0 RoHS No. Parts No. Parts Name Specifications R0 A CAPACITOR = 0V Q'ty / set PCH.,, AK Remarks (rawing No.) Wiring iagram Symbol C Recommended Q'ty Unit Price Amount TW E CAPACITOR = 0V C R0 A CAPACITOR = 0V C R0 E0 9 FUSE 0V.A FUSE TW E 0 INOOR CTROLLER BOAR I.B TW E TERMINAL BLOCK P (L,N, ) TB TW E TERMINAL BLOCK P (,,) TB TW E TERMINAL BLOCK P (,) TB CTROL BOX (B00N00) 8 TW E POWER BOAR CTROL COVER (B0A808) P.B 9 CTROL COVER (B0A809) CTROL COVER (B0A800) 0 TW E0 0 REMOTE CTROLLER COR 0m TW E REMOTE CTROLLER PAR-MAA R.B 8

86 ELECTRICAL PARTS PCH-AKH PCH-.AKH PCH-AKH PCH-AKH PCH-AKH PCH-AKH 9 8 TEMP. /OFF 0 RoHS No. Parts No. Parts Name Specifications R0 A CAPACITOR = 0V Q'ty / set PCH.,, AKH Remarks (rawing No.) Wiring iagram Symbol C Recommended Q'ty Unit Price Amount TW E CAPACITOR = 0V C R0 A CAPACITOR = 0V C R0 E0 9 FUSE 0V.A FUSE TW E 0 INOOR CTROLLER BOAR I.B TW E TERMINAL BLOCK P (L,N, ) TB TW E TERMINAL BLOCK P (,,) TB TW E TERMINAL BLOCK P (,) TB CTROL BOX (B00N0) 8 TW E POWER BOAR P.B 9 R0 E0 RELAY CTROL COVER JC-A CV (B0A808) 88H 0 CTROL COVER (B0A809) CTROL COVER (B0A800) TW E0 0 REMOTE CTROLLER COR 0m TW E REMOTE CTROLLER PAR-MAA R.B 8

87 OPTIAL PARTS -. REFRIERANT PIPES Service Ref. : PCH-AK(H), PCH-.AK(H), PCH-AK(H) Part No. PAC-0FFS-E PAC-0FFS-E PAC-0FFS-E PAC-FFS-E Pipe length m m 0m m Pipe size O.. Liquid:[9. as:[.88 Connection method Indoor unit: Flared Outdoor unit: Flared Service Ref. : PCH-AK(H),PCH-AK(H), PCH-AK(H) Part No. PAC-PCPI-E PAC-SCPI-E PAC-SCPI-E PAC-SCPI-E Pipe length m m 0m m Pipe size O.. Liquid:[9. as:[9.0 Connection method Indoor unit: Flared Outdoor unit: Flared Note. How to connect refrigerant pipes. Factory supplied optional refrigerant pipings contain refrigerant at the above atmospheric pressures. As long as the connection takes no more than minutes, no air will enter, and there will be no need for air purging. Remove the blind caps and make the connections within minutes. After the connections for the indoor and outdoor units are made, open the stop valve on the outdoor unit to allow refrigerant gas to flow. Note. The following main parts are contained in the optional refrigerant piping kit. Heat insulating cover, vinyl tapes, nipples, sleeve and flange (for wall hole). -. MULTIPLE REMOTE CTROLLER AAPTER This adapter is needed for remote indication (operation/check). Part No. Applicable Service Ref. PAC-SA88HA-E PCH-,.,,,, AK(H) BRN RE ORN YLW RN -. REMOTE /OFF AAPTER Part No. Applicable Service Ref. -. REMOTE SENSOR Part No. Applicable Service Ref. PAC-SERA-E PCH-,.,,,, AK(H) PAC-SETS-E PCH-,.,,,, AK(H) -. REMOTE OPERATI AAPTER Part No. Applicable Service Ref. PAC-SF0RM-E PCH-,.,,,, AK(H) 8

88 -.RAIN PUMP Part No. Applied Service Ref. PAC-SHM-E PCH-,., AK(H) PAC-SHM-E PCH-,, AK(H) Motor Casing (Inverted corn shape) rain water Rotating blabe (Inverted triangle plate) Flow of drain water Suction port -.HIH PERFORMANCE FILTER Part No. PAC-SE80KF-E PAC-SE8KF-E PAC-SE8KF-E Applicable Service Ref. PCH-AK(H) PCH-.,, AK(H) PCH-, AK(H) 88

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK T AVAILABLE C AMPM AMPM SPLIT-TYPE, HEAT PUM PAIR CDITIERS No. OC REVISED EDITI-A TECHNICAL & SERVICE MANUAL Series PLH Indoor unit [Model names] PLH-3AK PLH-3AKH PLH-AKS PLH-AKHS PLH-5AKS PLH-5AKHS PLH-6AKS

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE,HEAT PUMP AIR CDITIERS 1997 No. OC135 TECHNICAL & SERVICE MANUAL Series PCH Ceiling Suspended Indoor unit [Models names] [Service Ref.] PCH-2GKHA PCH-2.5GKHA PCH-3GKHA PCH-4GKHSA PCH-5GKHSA

More information

SERVICE MANUAL PCH-P50GAH PCH-P60GAH PCH-P71GAH PCH-P100GAH PCH-P125GAH PCH-P140GAH. May 2008

SERVICE MANUAL PCH-P50GAH PCH-P60GAH PCH-P71GAH PCH-P100GAH PCH-P125GAH PCH-P140GAH. May 2008 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS SERVICE MANUAL May 008 No. OC8 REVISED EDITION-B Indoor unit [Model names] [Service Ref.] PCA-RP0A PCA-RP0A PCA-RP0A# PCA-RP0A PCA-RP0A

More information

PKA-RP60FAL PKA-RP71FAL PKA-RP100FAL PKH-P60FALH PKH-P71FALH PKH-P100FALH

PKA-RP60FAL PKA-RP71FAL PKA-RP100FAL PKH-P60FALH PKH-P71FALH PKH-P100FALH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS May 005 No.OC33 SERVICE MANUAL Indoor unit [Model names] PKA-RP60FAL PKA-RP7FAL PKA-RP00FAL [Service Ref.] PKA-RP60FAL PKA-RP7FAL PKA-RP00FAL

More information

AA PLA-RP AA2 PEAD-RP EA PEAD-RP EA2 PEAD-RP GA PKA-RP GAL PKA-RP FAL PCA-RP GA PCA-RP HA PSA-RP GA

AA PLA-RP AA2 PEAD-RP EA PEAD-RP EA2 PEAD-RP GA PKA-RP GAL PKA-RP FAL PCA-RP GA PCA-RP HA PSA-RP GA SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL DATA BOOK [Model names] [Model names] PLA-RP AA PLA-RP AA PEAD-RP EA PEAD-RP EA PEAD-RP GA PKA-RP GAL PKA-RP FAL PCA-RP GA PCA-RP

More information

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TECHNICAL & SERVICE MANUAL. Ceiling Concealed STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL RA December 22 No. OCH REVISED EDITI-C Indoor unit [Model names] PKFY-PVBM-E PKFY-P2VBM-E PKFY-P2VBM-E [Service Ref.] PKFY-PVBM-E PKFY-PVBM-ER2

More information

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA(2) PEAD-RP125EA PEAD-RP140EA

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA(2) PEAD-RP125EA PEAD-RP140EA SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 005 SERVICE MANUAL Series PEAD R7C/RA Service ref. Models RP35EA() RP50EA RPEA RP7EA RP00EA() RP5EA RPEA NOTE: This manual describes only service data

More information

PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P20VBM-ER1 PKFY-P25VBM-E PKFY-P25VBM-ER1

PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P20VBM-ER1 PKFY-P25VBM-E PKFY-P25VBM-ER1 SPLIT-TYPE, HEAT PUMP AIR CDITIERS November No. OCH REVISED EDITI-A TECHNICAL & SERVICE MANUAL RA R7C R Indoor unit [Model names] PKFY-PVBM-E PKFY-PVBM-E PKFY-PVBM-E [Service Ref.] PKFY-PVBM-E PKFY-PVBM-E

More information

PKA-RP60KAL.TH PKA-RP71KAL.TH PKA-RP100KAL.TH

PKA-RP60KAL.TH PKA-RP71KAL.TH PKA-RP100KAL.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS SERVICE MANUAL May 2011 No. OCH452 REVISED EDITION-A Indoor unit [Model names] PKA-RP60KAL PKA-RP71KAL PKA-RP100KAL [Service Ref.] PKA-RP60KAL.TH

More information

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A Revision E: Capacity corrections have been corrected [7-1. 2), 3)]. OBH502 REVISED EDITION-D is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 REVISED EDITION-E Models MUZ-D30NA / - 1 / -

More information

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 Wireless type Models MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA Indoor unit service manual MSZ-D NA Series (OBH501) MSY-D

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

Air-Conditioners Indoor unit

Air-Conditioners Indoor unit Air-Conditioners Indoor unit PLA-A AA PKA-A A/PKA-A AL PKA-A FA/PKA-A FAL PCA-A A eutsch Nederlands Español Italiano ÏÏËÓÈÎ Português ansk Svenska OPERATI MANUAL FOR USER For safe and correct use, please

More information

SERVICE MANUAL MUZ-GB50VA - MUZ-GB50VA - E2 OUTDOOR UNIT. No. OB455 REVISED EDITION-D. Wireless type Models HFC

SERVICE MANUAL MUZ-GB50VA - MUZ-GB50VA - E2 OUTDOOR UNIT. No. OB455 REVISED EDITION-D. Wireless type Models HFC SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision D: RoHS PARTS LIST has been changed. Please void OB455 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB455 REVISED EDITION-D Wireless

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

SLZ-KF25VA.TH SLZ-KF35VA.TH SLZ-KF50VA.TH SLZ-KF60VA.TH

SLZ-KF25VA.TH SLZ-KF35VA.TH SLZ-KF50VA.TH SLZ-KF60VA.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL October 205 No. Indoor unit [Model Name] SLZ-KF25VA SLZ-KF35VA SLZ-KF50VA SLZ-KF60VA [Service Ref.] SLZ-KF25VA.TH SLZ-KF35VA.TH SLZ-KF50VA.TH

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

SERVICE TECHNICAL GUIDE

SERVICE TECHNICAL GUIDE SPLIT-TYPE, HEAT PUMP AIR CDITIERS SERVICE TECHNICAL GUIDE [Model names] PLA-RP AA PKA-RP GAL PKA-RP FAL PCA-RP GA PEA-RP EA PEAD-RP EA PEAD-RP GA [Model names] PUHZ-RP VHA

More information

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-SP100JA(L) PEAD-SP125JA(L) PEAD-SP140JA(L) Models PEAD-SP71JA(L) <indoor unit>

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-SP100JA(L) PEAD-SP125JA(L) PEAD-SP140JA(L) Models PEAD-SP71JA(L) <indoor unit> SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 4 SERVICE MANUAL Series PEAD R4A Models PEAD-SP7JA(L) PEAD-SPJA(L) PEAD-SP5JA(L) PEAD-SPJA(L) NOTE: This manual describes only service data of the indoor

More information

PKA-RP35HAL PKA-RP35HALR1 PKA-RP35HALR1-ER PKA-RP50HAL PKA-RP50HALR1 PKA-RP50HALR1-ER

PKA-RP35HAL PKA-RP35HALR1 PKA-RP35HALR1-ER PKA-RP50HAL PKA-RP50HALR1 PKA-RP50HALR1-ER SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS SERVICE MANUAL July 2014 No. OCH453 REVISED EDITION-A Indoor unit [Model Name] PKA-RP35HAL PKA-RP50HAL [Service Ref.] PKA-RP35HAL PKA-RP35HALR1

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

TECHNICAL & SERVICE MANUAL. Wall Mounted. Series PKFY PKFY-P20VAM-A PKFY-P25VAM-A R407C R22 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No.

TECHNICAL & SERVICE MANUAL. Wall Mounted. Series PKFY PKFY-P20VAM-A PKFY-P25VAM-A R407C R22 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. SPLIT-TYPE, HEAT PUMP AIR CDITIERS 00 No. OC TECHNICAL & SERVICE MANUAL Series PKFY Wall Mounted R07C R Indoor unit [Model names] PKFY-P0VAM-A [Service Ref.] PKFY-P0VAM-A CTENTS INDOOR UNIT. SAFETY PRECAUTI.

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL RESET SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. OC0 TECHNICAL & SERVICE MANUAL Series SLZ Ceiling Cassettes R0A Indoor unit [Model names] SLZ-A09AR SLZ-AAR SLZ-A8AR [Service Ref.] SLZ-A09AR.TH SLZ-AAR.TH

More information

PKA-RP35HAL PKA-RP50HAL

PKA-RP35HAL PKA-RP50HAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS March 2009 No. OCH453 SERVICE MANUAL Indoor unit [Model names] PKA-RP35HAL PKA-RP50HAL [Service Ref.] PKA-RP35HAL PKA-RP50HAL NOTE: This

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 12 TECHNICAL & SERVICE MANUAL Series SEZ Model name SEZ-KD25VA(L) SEZ-KD35VA(L) SEZ-KDVA(L) SEZ-KDVA(L) SEZ-KD71VA(L) INDOOR UNIT ON/OFF TEMP TEMP.

More information

PLFY-P15VCM-E3.TH PLFY-P20VCM-E3.TH PLFY-P25VCM-E3.TH PLFY-P32VCM-E3.TH PLFY-P40VCM-E3.TH

PLFY-P15VCM-E3.TH PLFY-P20VCM-E3.TH PLFY-P25VCM-E3.TH PLFY-P32VCM-E3.TH PLFY-P40VCM-E3.TH SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL June 04 No. Indoor unit [Model Name] PLFY-PVCM-E PLFY-P0VCM-E PLFY-PVCM-E PLFY-PVCM-E PLFY-P40VCM-E R40A [Service Ref.] PLFY-PVCM-E.TH PLFY-P0VCM-E.TH

More information

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL December No.HWE0 REVISED EDITION-B Indoor unit [Model names] SEZ-KD25VAQ SEZ-KD35VAQ SEZ-KDVAQ SEZ-KDVAQ SEZ-KD71VAQ [Service Ref.] SEZ-KD25VAQ.TH

More information

Floor Standing PFFY-P20VKM-E PFFY-P20VKM-ER1 PFFY-P25VKM-E PFFY-P25VKM-ER1 PFFY-P32VKM-E PFFY-P32VKM-ER1 PFFY-P40VKM-E PFFY-P40VKM-ER1

Floor Standing PFFY-P20VKM-E PFFY-P20VKM-ER1 PFFY-P25VKM-E PFFY-P25VKM-ER1 PFFY-P32VKM-E PFFY-P32VKM-ER1 PFFY-P40VKM-E PFFY-P40VKM-ER1 SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL November 008 No. OC0 REVISED EDITI-A Series PFFY Indoor unit [Model names] PFFY-P0VKM-E PFFY-PVKM-E PFFY-PVKM-E PFFY-P0VKM-E Floor Standing

More information

SERVICE MANUAL. Series PEA SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS CONTENTS

SERVICE MANUAL. Series PEA SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS CONTENTS SPLIT-TYPE, HEAT PUMP AIR CDITIERS 0 SERVICE MANUAL Series PEA Model name PEA-RP00GAQ PEA-RP0GAQ PEA-RP00GAQ PEA-RP00GAQ This manual describes only service data of the indoor units. CTENTS

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F. Revision F: The descriptions of the expansion valve coil have been corrected. (10-4.) Some descriptions have been modified. Please void OBH543 REVISED EDITION-E. OUTDOOR UNIT SERVICE MANUAL HFC utilized

More information

PKFY-P32VGM-E PKFY-P40VGM-E PKFY-P50VGM-E

PKFY-P32VGM-E PKFY-P40VGM-E PKFY-P50VGM-E SPLIT-TYPE, HEAT PUMP AIR CDITIERS July 00 No. OC0 REVISED EDITI-A TECHNICAL & SERVICE MANUAL Series PKFY Wall Mounted R0A R0C R [Model names] PKFY-PVGM-E PKFY-P0VGM-E PKFY-P0VGM-E [Service

More information

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100 Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW

More information

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Models HFC

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Models HFC Revision G: Errors in TROUBLESHOOTING have been corrected. Please void OB455 REVISED EDITION-F. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB455 REVISED EDITION-G Models MUZ-GB50VA - E1 MUZ-GB50VA

More information

MUH-24RV - MSH-30RV -

MUH-24RV - MSH-30RV - SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models Refer to the Service Manual OB85 REVISED EDITION C when MSH-8RV- E is connected with MXZ-NV- E or MXZ-NV- E as multi system units.

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467. SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

PEA-RP100, 125, 140GAA

PEA-RP100, 125, 140GAA Air-Conditioners PEA-RP00, 25, 40AA OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. English Contents.

More information

FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.

FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. Air-Conditioners PEA-A4,30,36,4AA OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. English MANUEL UTILISATION

More information

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1 Revision B: 3. SPECIFICATION has been corrected. Please void OBH732 REVISED EDITION-A. INDOOR UNIT SERVICE MANUAL. OBH732 REVISED EDITION-B Models MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA

More information

SERVICE MANUAL PKA-M60KA.TH PKA-M71KA.TH PKA-M100KA.TH PKA-M60KAL.TH PKA-M71KAL.TH PKA-M100KAL.TH R32/R410A. No. OCH661.

SERVICE MANUAL PKA-M60KA.TH PKA-M71KA.TH PKA-M100KA.TH PKA-M60KAL.TH PKA-M71KAL.TH PKA-M100KAL.TH R32/R410A. No. OCH661. SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS SERVICE MANUAL Indoor unit [Model Name] PKA-M60KA PKA-M7KA PKA-M00KA PKA-M60KAL PKA-M7KAL PKA-M00KAL [Service Ref.] R32/R40A PKA-M60KA.TH

More information

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Wireless type Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Wireless type Models HFC. Revision E: REVISED EDITION-E R410A Revision E: MUZ-GB50VA- E3 has been added. Please void OB455 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB455 REVISED EDITION-E Wireless type Models MUZ-GB50VA - E1 MUZ-GB50VA -

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS TECHNICAL & SERVICE MANUAL R07C Outdoor unit [model names] No.OC6 REVISED EDITION-B PUH-PVGAA PUH-P.6VGAA PUH-P.6YGAA PUH-PVGAA PUH-PYGAA

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS 004 TECHNICAL & SERVICE MANUAL R40A Outdoor unit [model names] PUHZ-RP.6VHA PUHZ-RPVHA PUHZ-RP.5VHA PUHZ-RP3VHA PUHZ-RP4VHA PUHZ-RP5VHA PUHZ-RP6VHA [Service Ref.] PUHZ-RP.6VHA

More information

SERVICE MANUAL. R410A Outdoor unit [model names] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS April 2007

SERVICE MANUAL. R410A Outdoor unit [model names] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS April 2007 SPLIT-TYPE, HEAT PUMP AIR CDITIERS SPLIT-TYPE, AIR CDITIERS April 007 No.OC379 REVISED EDITI-C SERVICE MANUAL R0A Outdoor unit [model names] PU-P7VHA PU-P7YHA PU-P00VHA PU-P00YHA PU-P5YHA PU-P0YHA PUH-P7VHA

More information

SERVICE MANUAL INDOOR UNIT MFZ-KA25VA - MFZ-KA50VA - MFZ-KA35VA - No. OB409. Models. Revision E: SPLIT-TYPE AIR CONDITIONERS REVISED EDITION-E

SERVICE MANUAL INDOOR UNIT MFZ-KA25VA - MFZ-KA50VA - MFZ-KA35VA - No. OB409. Models. Revision E: SPLIT-TYPE AIR CONDITIONERS REVISED EDITION-E SPLIT-TYPE AIR CONDITIONERS Revision E: MFZ-KA5VA- E5, MFZ-KA35VA- E5 and MFZ-KA50VA- E5 have been added. Please void OB409 REVISED EDITION-D. INDOOR UNIT SERVICE MANUAL. OB409 REVISED EDITION-E Models

More information

Air-Conditioners PKA-A HA/PKA-A HAL PCA-A KA. Indoor unit OPERATION MANUAL. English

Air-Conditioners PKA-A HA/PKA-A HAL PCA-A KA. Indoor unit OPERATION MANUAL. English Air-Conditioners Indoor unit PKA-A HA/PKA-A HAL PCA-A KA OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. English

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS December No. OCH7 REVISED EDITI-B TECHNICAL & SERVICE MANUAL RA R7C R Indoor unit [Model names] PKFY-PVKM-E PKFY-PVKM-E [Service Ref.] PKFY-PVKM-E.TH PKFY-PVKM-ER.TH

More information

SERVICE MANUAL MUCFH-GA35VB - MUCFH-GA50VB - MUCFH-GA60VB - E1 OUTDOOR UNIT. No. OB381. Models HFC

SERVICE MANUAL MUCFH-GA35VB - MUCFH-GA50VB - MUCFH-GA60VB - E1 OUTDOOR UNIT. No. OB381. Models HFC FLOOR AND CEILIN TYPE AIR CONDITIONERS Revision B: The fan guard for MUCFH-A 60VBhas been changed. Please void OB8 REVSED EDITION-A. E OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB8 REVISED EDITION-B

More information

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA OUTDOOR UNIT. No. OBH543. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA OUTDOOR UNIT. No. OBH543. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH543 Models MUZ-FE09NA MUZ-FE12NA Indoor unit service manual MSZ-FE NA Series (OBH542) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 2010 SERVICE MANUAL PEA-RP200GAQ PEA-RP250GAQ PEA-RP400GAQ PEA-RP500GAQ. [Model names] CONTENTS

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 2010 SERVICE MANUAL PEA-RP200GAQ PEA-RP250GAQ PEA-RP400GAQ PEA-RP500GAQ. [Model names] CONTENTS SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 00 SERVICE MANUAL [Model names] PEA-RP00GAQ PEA-RP50GAQ PEA-RP400GAQ PEA-RP500GAQ This manual describes only service data of the indoor units. CONTENTS Indoor unit.

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE

More information

SERVICE MANUAL MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No.

SERVICE MANUAL MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No. SPLIT-TYPE AIR CONDITIONERS Revision E: Detail of the indoor fan speed control in COOL or DRY operation has been added (9-1.3, 9-2.3). Please void OBH515 REVISED EDITION-D. INDOOR UNIT SERVICE MANUAL.

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

PLFY-P32VAM-E.UK PLFY-P40VAM-E.UK PLFY-P50VAM-E.UK PLFY-P63VAM-E.UK PLFY-P80VAM-E.UK PLFY-P100VAM-E.UK PLFY-P125VAM-E.UK

PLFY-P32VAM-E.UK PLFY-P40VAM-E.UK PLFY-P50VAM-E.UK PLFY-P63VAM-E.UK PLFY-P80VAM-E.UK PLFY-P100VAM-E.UK PLFY-P125VAM-E.UK SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL July No. OC REVISED EDITI-B Indoor unit [Model names] PLFY-PVAM-E PLFY-PVAM-E PLFY-PVAM-E PLFY-PVAM-E PLFY-PVAM-E PLFY-PVAM-E PLFY-PVAM-E [Service

More information

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type 11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER ( Split system, Air cooled ) cooling only type FDKN8CEN-S, FDKN8CEP-S, FDKN8CEN FDKN8CEP, FDKN258CEN-S, FDKN258CEP-S FDKN258CEN, FDKN258CEP, FDKN8CEN FDKN8CEP,

More information

SERVICE MANUAL MFZ-KA25VA - MFZ-KA35VA - MFZ-KA35VA - E1. Wireless type Models FLOOR-TYPE, HEAT PUMP AIR CONDITIONERS. No.

SERVICE MANUAL MFZ-KA25VA - MFZ-KA35VA - MFZ-KA35VA - E1. Wireless type Models FLOOR-TYPE, HEAT PUMP AIR CONDITIONERS. No. FLOOR-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models MFZ-KAVA - MFZ-KA3VA - E E. OB409 MFZ-KA0VA - E Indication of model name MFZ-KAVA - E MFZ-KA3VA - E MFZ-KA0VA - E NOTE: This service

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

Air-Conditioners. Indoor unit PSA-RP KA OPERATION MANUAL. English

Air-Conditioners. Indoor unit PSA-RP KA OPERATION MANUAL. English Air-Conditioners Indoor unit PSA-RP KA OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. English Contents 1. Safety

More information

SERVICE MANUAL MLZ-KA25VA - MLZ-KA35VA - MLZ-KA50VA - E1 INDOOR UNIT. No. OBH483. Ceiling cassette type Models

SERVICE MANUAL MLZ-KA25VA - MLZ-KA35VA - MLZ-KA50VA - E1 INDOOR UNIT. No. OBH483. Ceiling cassette type Models CEILING CASSETTE TYPE, HEAT PUMP AIR CONDITIONERS INDOOR UNIT SERVICE MANUAL. OBH483 Ceiling cassette type Models E1 MLZ-KA25VA - E1 MLZ-KA35VA - MLZ-KA50VA - E1 Outdoor unit service manual MXZ-A VA Series

More information

SERVICE MANUAL MUH-GA50VB- MUH-GA50VB - MUH-GA60VB - MUH-GA80VB - E1 OUTDOOR UNIT. No. OB368 REVISED EDITION-B. Wireless type Models HFC.

SERVICE MANUAL MUH-GA50VB- MUH-GA50VB - MUH-GA60VB - MUH-GA80VB - E1 OUTDOOR UNIT. No. OB368 REVISED EDITION-B. Wireless type Models HFC. Revision:B - E has been added. SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Please void OB68 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB68 REVISED EDITION-B Wireless type Models E -

More information

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER Manual No. '06 PAC, KX-T-110 TECHNICAL MANUAL Collection data PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) FDUMVA201HEN2R 251HEN2R 302HEN2R 402HEN2R 502HEN2R 602HEN2R MULTI-TYPE (V-MULTI)

More information

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589) SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service

More information

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2 Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models

More information

SERVICE MANUAL MSZ-HM09NA MSZ-HM12NA MSZ-HM15NA MSZ-HM18NA MSZ-HM24NA INDOOR UNIT. No. OBH746 REVISED EDITION-B. Models

SERVICE MANUAL MSZ-HM09NA MSZ-HM12NA MSZ-HM15NA MSZ-HM18NA MSZ-HM24NA INDOOR UNIT. No. OBH746 REVISED EDITION-B. Models Revision B: 3-1. OPERATING RANGE has been modified. Please void OBH746 REVISED EDITION-A. INDOOR UNIT SERVICE MANUAL. OBH746 REVISED EDITION-B Models MSZ-HM09NA MSZ-HM12NA MSZ-HM15NA MSZ-HM18NA MSZ-HM24NA

More information

Contents. 1. Safety Precautions

Contents. 1. Safety Precautions Contents. Safety Precautions....................................... Parts Names........................................... 3 3. Screen Confi guration.................................... 6 4. Setting the

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax: Tel: 08 0 www.heronhill.co.uk Fax: 08 80 TOSHIBA Heronhill - for all your Toshiba requirements FILE NO. A90-00 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE, HEAT PUMP COOLING ONLY WAY CASSETTE TYPE RAV-0TUH--PE

More information

Кондиционеры Mitsubishi Heavy

Кондиционеры Mitsubishi Heavy Кондиционеры Mitsubishi Heavy Техническое руководство Кондиционеры настенного типа SRK28HD, SRK40HD INDOOR UNIT Models SRK28HD, SRK40HD OUTDOOR UNIT Model SRC28HD REMOTE CONTROLLER Model SRC40HD GENERAL

More information

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1 SPLIT-TYPE AIR CONDITIONERS Revision D: Changing defrost finish temperature has been corrected (10-1.). Please void OBH516 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED

More information

TECHNICAL & SERVICE MANUAL. Ceiling Cassettes

TECHNICAL & SERVICE MANUAL. Ceiling Cassettes RESET RESET SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SLH/SL Indoor unit [Model names] SLH-AR SLH-.6AR SLH-AR SL-AR SL-.6AR SL-AR Ceiling Cassettes

More information

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type J-Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type J-Series Heat Pump Indoor Unit FTX20JV1B FTX25JV1B FTX35JV1B FTX20J2V1B

More information

SERVICE MANUAL MSC-A07YV - (WH) MSC-A09YV - (WH) MSC-A12YV - (WH) HFC. Wireless type Models

SERVICE MANUAL MSC-A07YV - (WH) MSC-A09YV - (WH) MSC-A12YV - (WH) HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models E MSC-A07YV - (WH) E MSC-A09YV - (WH) E MSC-AYV - (WH) HFC utilized R40A. OB39 CONTENTS Indication

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

SERVICE MANUAL INDOOR UNIT

SERVICE MANUAL INDOOR UNIT SPLIT-TYPE AIR CONDITIONERS Revision A: MSZ-SF25/35/42/50VE- E2 and MSZ-SF25/35/ 42/50VE- EN2 have been added. Please void OBH600. INDOOR UNIT SERVICE MANUAL. OBH600 REVISED EDITION-A Models MSZ-SF25VE

More information

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT SERVICE MANUAL. OBH589 Models MSZ-EF22VEW - MSZ-EF22VEW - E1 MSZ-EF25VEW - E1 MSZ-EF22VEB - E1 MSZ-EF35VEW - E1 MSZ-EF22VES E1 - MSZ-EF42VEW - E1 MSZ-EF25VEW - E1

More information

MSZ-GE06NA- 8, 9 MSZ-GE09NA- 8, 9 MSZ-GE12NA- 8, 9 MSZ-GE15NA- 8, 9 MSZ-GE18NA- 8, 9

MSZ-GE06NA- 8, 9 MSZ-GE09NA- 8, 9 MSZ-GE12NA- 8, 9 MSZ-GE15NA- 8, 9 MSZ-GE18NA- 8, 9 SPLIT-TYPE AIR CONDITIONERS Revision D: MSZ-GE06/09/12/15/18NA- 9 and MSY- GE09/12/15/18NA- 9 have been added. Please void OBH548 REVISED EDITION-C INDOOR UNIT SERVICE MANUAL. OBH548 REVISED EDITION-D

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271

More information

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL

More information

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type

More information

Part 3 Troubleshooting

Part 3 Troubleshooting Part Troubleshooting What is in this part? This part contains the following chapters: Chapter See page Troubleshooting 2 Error Codes: Hydro-box 7 Error Codes: Outdoor Units Error Codes: System Malfunctions

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338 TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE9NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 9,000BTU / h 11,900BTU / h 17,500BTU

More information

SERVICE MANUAL MSC-GE20VB - E1 MSC-GE25VB - E1 MSC-GE35VB - E1 MS-GE50VB - E1 MSH-GE50VB - E1 INDOOR UNIT. No. OBH529. Models

SERVICE MANUAL MSC-GE20VB - E1 MSC-GE25VB - E1 MSC-GE35VB - E1 MS-GE50VB - E1 MSH-GE50VB - E1 INDOOR UNIT. No. OBH529. Models SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT SERVICE MANUAL. OBH529 Models MSC-GE20VB - E1 MSC-GE25VB - E1 MSC-GE35VB - E1 MS-GE50VB - E1 MSH-GE50VB - E1 service manual MU-GA VB Series (OB386) MUH-GA VB Series

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

SERVICE MANUAL MSZ-D30NA MSZ-D36NA MSY-D30NA MSY-D36NA INDOOR UNIT. No. OBH501. Wireless type Models

SERVICE MANUAL MSZ-D30NA MSZ-D36NA MSY-D30NA MSY-D36NA INDOOR UNIT. No. OBH501. Wireless type Models INDOOR UNIT SERVICE MANUAL. OBH501 Wireless type Models MSZ-D30NA MSZ-D36NA MSY-D30NA MSY-D36NA CONTENTS Outdoor unit service manual MUZ-D NA Series (OBH502) MUY-D NA Series (OBH502) 1. TECHNICAL CHANGES

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL R40A Outdoor unit [model names] SUZ-KA5VA SUZ-KA35VA SUZ-KA5VAH SUZ-KA35VAH SUZ-KA50VA SUZ-KA60VA SUZ-KA7VA [Service Ref.] SUZ-KA5VA.TH

More information

SERVICE MANUAL MUX-A22WV - E1 HFC. Multi system type Model SPLIT-TYPE, AIR CONDITIONER. No. OB318 R410A CONTENTS. Revision A: MUX-A22WV -

SERVICE MANUAL MUX-A22WV - E1 HFC. Multi system type Model SPLIT-TYPE, AIR CONDITIONER. No. OB318 R410A CONTENTS. Revision A: MUX-A22WV - SPLIT-TYPE, AIR CDITIER Revision A: MUX-AWV - E can be connected to MSC-A07/AYV - E. PARTS LIST has partially modified. Please void OB8. SERVICE MANUAL Multi system type Model HFC utilized R40A. OB8 REVISED

More information

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

SERVICE MANUAL MSZ-FH25VE MSZ-FH35VE INDOOR UNIT. No. OBH623. Models SPLIT-TYPE AIR CONDITIONERS

SERVICE MANUAL MSZ-FH25VE MSZ-FH35VE INDOOR UNIT. No. OBH623. Models SPLIT-TYPE AIR CONDITIONERS SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT SERVICE MANUAL. Models MSZ-FH25VE MSZ-FH35VE - E1 - E1 Outdoor unit service manual MUZ-FH VEHZ Series (OBH625) MUZ-FH VE Series MXZ-D VA Series CONTENTS 1. TECHNICAL

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information