HIGH-POWER HEAT PUMPS. Up to 300 kw
|
|
- Louise McLaughlin
- 6 years ago
- Views:
Transcription
1 HIGH-POWER HEAT PUMPS Up to 300 kw 1
2 2
3 NEW GENERATION OF HEAT PUMPS GORENJE 4 COMPLETE RANGE OF NEW GENERATION HIGH-POWER HEAT PUMPS 8 MODERN CONTROL UNIT HEAT PUMPS AIR-WATER 10 Heat pumps AEROGOR COMPACT W 11 Heat pumps AEROGOR COMPACT EVI W 12 Heat pumps AEROGOR SPLIT AW W 13 Heat pumps AEROGOR SPLIT AW EVI W 14 Heat pumps AEROGOR SPLIT HD W 15 Heat pumps AEROGOR SPLIT HD EVI W GEOTHERMAL HEAT PUMPS BRINE-WATER AND WATER-WATER 18 Heat pumps AQUAGOR TERRAGOR W 19 Heat pumps AQUAGOR TERRAGOR EVI W 20 Table of recommended circulating pumps 21 Operating range 22 Technical specification 3
4 COMPLETE RANGE OF NEW GENERATION HIGH-POWER HEAT PUMPS Model name Outlet water temperature Number of compressors Model name Outlet water temperature Number of compressors Model name Outlet water temperature Number of compressors Aerogor Compact W 60 C 1 Aerogor Split AW W 60 C 1 Aerogor Split HD 107 W 60 C 2 Aerogor Compact EVI W 65 C 1 Aerogor Split AW EVI W 65 C 1 Aerogor Split HD EVI 109 W 65 C 2 4
5 Model name Outlet water temperature Number of compressors Model name Outlet water temperature Number of compressors Model name Outlet water temperature Number of compressors Aerogor Split HD EVI 163 W 65 C 3 Aquagor 37 W 60 C 2 Aquagor W 60 C 2 Terragor 28 W 60 C 2 Terragor W 60 C 2 Aquagor EVI W 65 C 2 Terragor EVI W 65 C 2 5
6 MAIN ADVANTAGES OF HEAT PUMP WATER HEATERS -20 C LOW OPERATING COSTS HIGH TEMPERATURE OPERATION OPERATION AT ENVIRONMENT TEMPERATURE OF DOWN TO -20 C EUROPEAN QUALITY SILENT AND RELIABLE OPERATION Efficient operation with high coefficient of performance excellent COP. The heat pump reaches high temperatures of heating water; therefore, it is also suitable for conventional radiator systems. It is appropriate for both floor heating and radiator heating system (with higher heating water requirements of up to 65 C). The system can successfully operate down to environment temperatures of -20 C. Components by European manufacturers are installed in the heat pump, which guarantees quality and long useful life. It is allowed by the scroll compressor technology, topclass sound insulation, and ultrasilent axial fan. 6
7 ECONOMICAL AND EFFICIENT GORENJE HIGH-POWER HEAT PUMPS ARE INTENDED FOR LARGE BUILDINGS Economical and efficient heating system with Gorenje heat pumps is a smart choice for both new and existing buildings. High-power heat pumps are intended for larger buildings housing, for example, public institutions (schools, kindergardens, banks etc.) or smaller to medium-sized industrial and commercial premises (offices, sports halls, restaurants etc.). They are suitable for both low-temperature heating systems (new buildings with floor heating or low-temperature radiators) and buildings with high-temperature heating systems with conventional radiators (refurbished or older buildings) as they can heat the water to a temperature of 55 to 65 C. We offer two types of high-power geothermal heat pumps: Characteristics of high-power heat pumps: Aquagor W water/water heat pumps with heating capacity ranging from 37 to 115 kw. Terragor W brine/water heat pumps with heating capacity ranging from 28 to 83 kw. Aquagor EVI W water/water heat pump with heating capacity ranging from 48 to 126 kw. Terragor EVI W brine/water heat pumps with heating capacity ranging from 37 to 98 kw. Moreover, we offer different types of air-water heat pumps with wide range of heating capacity ( kw): Aerogor Compact W Aerogor Compact EVI W Aerogor Split AW W Aerogor Split AW EVI W Aerogor Split HD 107 W Aerogor Split HD EVI 109/163 W Geothermal heat pumps operate in two levels/cycles: Two compressors operate in a cascade system to allow the adjustment of heating power to the heating requirements of the building in different periods of the heating season. High-temperature heat pumps can heat the water to a temperature of 65 C: Aerogor Compact EVI W / Split AW EVI W / Split HD EVI W Terragor EVI W Aquagor EVI W Low-temperature heat pumps can heat the water to a temperature of 55 to 60 C: Aerogor Compact W / Split AW W / Split HD W Terragor W Aquagor W Complete range or air-water heat pumps allows active cooling mode during the hot summer months (serial integrated 4- way reversible valve and electronic expanison valve enables this procces). Geothermal heat pumps (brine-water / water- water) allows passive cooling mode in combination with preheat exchanger. Active cooling mode - optionally (on the request). ACTIVE/PASIVE COOLING HEATING MODE The heat pumps can operate in cascade system: 60/65 C DOMESTIC HOT WATER ACTIVE COOLING HEATING MODE DOMESTIC HOT WATER 7
8 MODERN CONTROL UNIT Modern control unit allows different settings for heating, cooling, and domestic hot water heating. The regulation is weather-dependent. The control unit regulates the heat pump and heating system operation according to the outdoor environment temperature and the desired indoor temperature in the user s home. Owing to a special algorithm, the heat pump only generates as much heat as required by the heating system, in any given moment. Basic regulation Basic regulation of RVS 61 supports two independent heating circuits one direct and one mixing circuit. For each circuit, the heating curve is set independently. Basic regulation of RVS 21 supports regulation of one direct heating circuit and DHW circuit. Basic regulation (RVS 61 and RVS 21) also supports heating of sanitary water with anti-legionella program, as well as alternative sources such as solar panels or wood-fired furnaces. It also allows hasslefree regulation of additional sources such as a heating oil or gas burner. Electronic controls are universal for all types of heat pumps and heating methods. In case of major systems, upgrading the basic regulation unit is quite straightforward. In most cases, heating circuit regulation depends on the exterior temperature. The heating curve depends on the characteristics of the building being heated, which is the only warranty that the heat pump, regardless of the outdoor temperature, will always heat the water to the lowest acceptable temperature. The level of temperature thus defines the efficiency of the heating system. The lower the heating temperature, the higher the Coefficient of Performance. RVS 21 RVS 61 Easy control Menu navigation is plain and simple. Each screen is indicated with a consecutive number so that the user is aware at all times which page of the menu is currently open. Commands re indicated with appropriate wording. The unit can be controlled via user keyboard on the heat pump, or through an additional room control unit. Basic functions are available through keys on the control unit and heating system temperature is easily set with a rotating dial located in the middle of the control unit. For advanced users, controls can also be routed hrough interfaces to a personal computer or even to an intelligent home system. INSTALLED HP CONTROLLER SIEMENS RVS 61 Control of direct HC*: Control of DHW circuit: Control active/passive cooling mode: Control of mixing HC*: Control of direct pump HC*: Solar system control: *HC = heating circuit Aerogor Compact W Aerogor Compact EVI W Aerogor Split AW W Aerogor Split AW EVI W Aerogor Split HD 107 W Aerogor Split HD EVI 109 W Aerogor Split HD EVI 163 W Aquagor Terragor W INSTALLED HP CONTROLLER SIEMENS RVS 21 Control of direct HC*: Control of DHW circuit: Active cooling mode: Control of mixed HC*: Control of direct pump HC*: Solar system control: with EXM** with EXM** with EXM** 8 Aquagor Terragor EVI W *HC = heating circuit **EXM = Extension module
9 Electronic control enable regulation of different heating systems Smart Web - remote control Large buildings in lot of cases need for different parts of the building different temperature regulation. Control units of heat pumps Gorenje enable regulation of different heating/cooling zones. Here are solutions for some cases. Regulation of different heating zones with control unit Siemens RVS 61 CASE 1: 3 HEATING ZONES WITH 3 MIXING HEATING CIRCUITS: 1st mixing heating circuit: controlled by Basic control unit RVS 61 2nd mixing heating circuit: Extension module Siemens AVS75.390/109 1 x NTC temperature sensor 3rd mixing heating circuit: Extension module RVS46.530/101 Regulation of different heating zones with control unit Siemens RVS 21 CASE 1: 3 HEATING ZONES WITH 3 MIXING HEATING CIRCUITS: 1st mixing heating circuit: Extension module Siemens AVS75.390/109 1 x NTC temperature sensor 2nd mixing heating circuit: Extension module Siemens AVS75.390/109 1 x NTC temperature sensor 3rd mixing heating circuit: Extension module RVS46.530/101 1 x NTC temperature sensor Room unit advanced/cooling/wired QAA75.611/701 CASE 2: 3 HEATING ZONES WITH 1 DIRECT AND 2 MIXING CIRCUITS: 1st direct heating circuit: The Smart Web application allows you to monitor your heat pump operation regardless of where you are. An internet connection can be used to connect the heat pump controllers to your personal computer or your cell phone. Thus, the system allows you to monitor the settings, to keep up to date with the device operating status, and to receive a warning in case of any failures. This makes remote control of your heating system convenient as well as cost and energy-effective due to constant control over equipment operation. Heat pump electronic control unit 1 x NTC temperature sensor Room unit advanced/cooling/wired QAA75.611/701 controlled by Basic control unit RVS 21 2nd mixixng heating circuit: USB Ethernet CASE 2: 3 HEATING ZONES WITH 1 DIRECT AND 2 MIXING CIRCUITS: 1st direct heating circuit: Extension module Siemens AVS75.390/109 1 x NTC temperature sensor OZW 164 controlled by Basic control unit RVS 61 3rd direct heating circuit: 1st mixing heating circuit: Extension module Siemens AVS75.390/109 controlled by Basic control unit RVS 61 1 x NTC temperature sensor 2nd mixing heating circuit: CASE 3: 3 ZONES WITH 3 DIRECT HEATING CIRCUITS: Extension module AVS75.390/109 1st direct heating circuit: 1 x NTC Temperature sensor controlled by Basic control unit RVS 21 CASE 3: 3 ZONES WITH 3 DIRECT HEATING CIRCUITS: 2nd direct heating circuit: Alarm 1st and 2nd direct heating circuit: controlled by Basic control unit RVS 61 Extension module Siemens AVS75.390/10 1 x NTC temperature sensor Internet 3rd direct heating circuit: 3nd direct heating circuit: Extension module Siemens AVS75.390/109 Extension module Siemens AVS75.390/109 1 x NTC temperature sensor 1 x NTC temperature sensor 9
10 HEAT PUMPS AEROGOR COMPACT W AIR WATER AEROGOR COMPACT W The main components and temperature sensors Compact outdoor unit Indoor unit Basic: DisplayBox W Display of control unit (HMI) Heating/Cooling mode HIGH TEMPERATURE OPERATION Advanced: ControlBox W main power switch display from control unit 1 x extension module AVS Heating/Cooling/DHW mode LEGEND MAIN ADVANTAGES Operating modes 10 Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 Type: Copeland scroll ZH High efficiency and quite scroll technology Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 60 C (55 C up to ambient temperature -15 C) High efficiency Scroll ZH compressor (1 X) SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 10 meter LAN cable with RJ45 connectors 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package
11 HEAT PUMPS AEROGOR COMPACT EVI W AIR WATER AEROGOR COMPACT EVI W The main components and temperature sensors Compact outdoor unit Indoor unit Basic: DisplayBox W Display of control unit (HMI) Heating/Cooling mode HIGH TEMPERATURE OPERATION Advanced: ControlBox W main power switch display from control unit 1 x extension module AVS Heating/Cooling/DHW mode LEGEND MAIN ADVANTAGES Operating modes Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 Type: Copeland scroll ZH EVI Extreme good performances Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 65 C (up to ambient temperature -20 C) High efficiency Scroll EVI compressor (1 X) SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 10 meter LAN cable with RJ45 connectors 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package 11
12 HEAT PUMPS AEROGOR SPLIT AW W AIR WATER AEROGOR SPLIT AW W The main components and temperature sensors Compact outdoor unit Indoor unit HIGH TEMPERATURE OPERATION LEGEND MAIN ADVANTAGES Operating modes 12 Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 Type: Copeland scroll ZH High efficiency and quite scroll technology Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 60 C (55 C up to ambient temperature -15 C) High efficiency Scroll ZH compressor (1 X) SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package
13 HEAT PUMPS AEROGOR SPLIT AW EVI W AIR WATER AEROGOR SPLIT AW EVI W The main components and temperature sensors Compact outdoor unit Indoor unit HIGH TEMPERATURE OPERATION LEGEND MAIN ADVANTAGES Operating modes Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 Type: Copeland scroll ZH EVI Extreme good performances Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 65 C (up to ambient temperature -20 C) High efficiency Scroll EVI compressor (1 X) SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package 13
14 HEAT PUMPS AEROGOR SPLIT HD W AIR WATER AEROGOR SPLIT HD 107 W The main components and temperature sensors Outdoor unit 1 Outdoor unit 2 Indoor unit (2 x compressors) HIGH TEMPERATURE OPERATION LEGEND MAIN ADVANTAGES Operating modes 14 Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 and 2 Type: Copeland scroll ZH High efficiency and quite scroll technology Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 60 C (up to ambient temperature -15 C) 2 X High efficiency Scroll ZH compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 2 x EEV (electonic expansion valve) + 2 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package
15 HEAT PUMPS AEROGOR SPLIT HD EVI W AIR WATER AEROGOR SPLIT HD EVI 109 W The main components and temperature sensors Outdoor unit 1 Outdoor unit 2 Indoor unit (2 x compressors) HIGH TEMPERATURE OPERATION LEGEND MAIN ADVANTAGES Operating modes Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 and 2 Type: Copeland scroll ZH EVI Extreme good performances Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 65 C (up to ambient temperature -20 C) 2 X High efficiency Scroll EVI compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 2 x EEV (electonic expansion valve) + 2 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package 15
16 HEAT PUMPS AEROGOR SPLIT HD EVI W AIR WATER AEROGOR SPLIT HD EVI 163 W The main components and temperature sensors Outdoor unit 1 Outdoor unit 2 Outdoor unit 3 Indoor unit (3 x compressors) HIGH TEMPERATURE OPERATION LEGEND MAIN ADVANTAGES Operating modes 16 Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressors 1, 2, 3 Type: Copeland scroll ZH EVI Extreme good performances Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor Max. Outlet water temperature: 65 C (up to ambient temperature -20 C) 3 X High efficiency Scroll EVI compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 3 x EEV (electonic expansion valve) + 3 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part APS System Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package
17 17
18 GEOTHERMAL HEAT PUMPS BRINE-WATER AND WATER-WATER HEAT PUMPS AQUAGOR TERRAGOR W The main components and temperature sensors Geothermal heat pumps operate in two levels/cycles: Two compressors operate in a cascade system to allow the adjustment of heating power to the heating requirements of the building in different periods of the heating season. HIGH TEMPERATURE OPERATION ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package MAIN ADVANTAGES Max. Outlet water temperature: 60 C Passive cooling mode Reverse active cooling optional 2 X High efficiency Scroll ZH compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) Large surface condenser and evaporator plate heat exchanger Robust and solid refrigeration cycle designed for highest stability and long term high performance Operating modes 18 LEGEND Q8: circulating pump on source side Q9: circulating pump on the secondary side (condenser) B91: inlet temperature sensor of source side (evaporator) B92: outlet temperature sensor of source side (evaporator) K1 / E11: compressor 1 K2 / E12: compressor 2 B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE/PASIVE COOLING
19 HEAT PUMPS AQUAGOR TERRAGOR EVI W The main components and temperature sensors Geothermal heat pumps operate in two levels/cycles: Two compressors operate in a cascade system to allow the adjustment of heating power to the heating requirements of the building in different periods of the heating season. HIGH TEMPERATURE OPERATION ACCESSORIES LIST 1 x Outdoor temperature sensor for weather-dependent regulation 2 x cable temperature (+5 to 95 C) sensors in the package MAIN ADVANTAGES Max. Outlet water temperature: 65 C Passive cooling mode Reverse active cooling optional 2 X High efficiency Scroll ZH compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 2 x EEV (electonic expansion valve) Large surface condenser and evaporator plate heat exchanger Robust and solid refrigeration cycle designed for highest stability and long term high performance Operating modes LEGEND Q8: circulating pump on source side Q9: circulating pump on the secondary side (condenser) B91: inlet temperature sensor of source side (evaporator) B92: outlet temperature sensor of source side (evaporator) K1 / E11: compressor 1 K2 / E12: compressor 2 B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: Flow switch build-in Pressure switch heating water (0,7 bar) Soft start module for compressor (Danfoss) Motor protection for compressor Crankcase heater for compressor Motor protection for fan Phase direction control High tariff lock Compressor over clock protection HEATING MODE DOMESTIC HOT WATER ACTIVE/PASIVE COOLING 19
20 OPERATING RANGE FOR AEROGOR COMPACT W AND AEROGOR COMPACT EVI W 70 OPERATING RANGE OF: AEROGOR COMPACT EVI W AEROGOR SPLIT HD EVI W OUTLET WATER TEMPERATURE [ C] OUTSIDE AMBIENT TEMPERATURE [ C] Optimum Maximum 70 OPERATING RANGE OF: AEROGOR COMPACT W AEROGOR SPLIT AW W, AEROGOR SPLIT HD W OUTLET WATER TEMPERATURE [ C] OUTSIDE AMBIENT TEMPERATURE [ C] 20
21 OPERATING RANGE FOR AQUAGOR TERRAGOR W AND AQUAGOR TERRAGOR EVI W OPERATING RANGE TERRAGOR W OPERATING RANGE TERRAGOR EVI W OUTLET WATER TEMPERATURE [ C] OUTLET WATER TEMPERATURE [ C] SOURCE (BRINE) TEMPERATURE [ C] SOURCE (BRINE) TEMPERATURE [ C] OPERATING RANGE AQUAGOR W OPERATING RANGE AQUAGOR EVI W OUTLET WATER TEMPERATURE [ C] OUTLET WATER TEMPERATURE [ C] SOURCE (WATER) TEMPERATURE [ C] SOURCE (WATER) TEMPERATURE [ C] 21
22 TABLE OF RECOMMENDED CIRCULATING PUMPS FOR AQUAGOR TERRAGOR W AND AQUAGOR TERRAGOR EVI W Model name Primary side source side (brine)* Secondary side heating side Terragor 28 W Aquagor 37 W Terragor 38 W Aquagor 50 W Terragor 43 W Aquagor 59 W Terragor 52 W Aquagor 67 W Terragor 56 W Aquagor 78 W Terragor 65 W Aquagor 89 W Terragor 70 W Aquagor 100 W Terragor 83 W Aquagor 115 W Terragor EVI 67 W Aquagor EVI 87 W Terragor EVI 81 W Aquagor EVI 105 W Terragor EVI 98 W Aquagor EVI 126 W WILO Stratos 40/1-8 WILO Stratos 30/1-8 WILO Stratos 50/1-8 WILO Stratos 50/1-8 WILO Stratos 50/1-8 WILO Stratos 50/1-8 WILO Stratos 50/1-9 WILO Stratos 50/1-8 WILO Stratos 50/1-9 WILO Stratos 50/1-8 WILO Stratos 65/1-12 WILO Stratos 65/1-12 WILO Stratos 80/1-12 WILO Stratos 80/1-12 WILO Stratos 80/1-12 WILO Stratos 80/1-12 WILO Stratos 65/1-12 WILO Stratos 65/1-12 WILO Stratos 80/1-12 WILO Stratos 80/1-12 WILO Stratos 80/1-12 WILO Stratos 80/ * Valid only for systems brine-water. On the primary (source) side of heat pump waterwater must be built-in submersible pump for the underground water. Type of submersible pump is depend on the deepness of borehole of and the distance (pipe length) from borehole to the heat pump.
23 Split system air / water : outdoor unit + indoor unit AEROGOR SPLIT HD W and SPLIT EVI HD W Model name Aerogor Split HD 107 W 2 x outdoor unit Aerogor Split HD EVI 109 W 2 x outdoor unit Aerogor Split HD EVI 163 W 3 x outdoor unit Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Code number 2 x / x / x / Connection between outdoor and indoor unit Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Heating capacity A7/W35 kw 106,60 109,04 163,33 COP A7/W35 / 4,77 4,91 4,91 Heating capacity A7/W45 kw 102,37 110,31 165,24 COP A7/W45 / 3,79 4,04 4,04 Heating capacity A7/W55 kw 96,66 112,34 168,28 COP A7/W55 / 3,00 3,31 3,31 Heating capacity A7/W65 kw / 112,76 168,91 COP A7/W65 / / 2,72 2,72 Heating capacity A2/W35 kw 86,73 93,46 140,00 COP A2/W35 / 3,70 3,80 3,80 Heating capacity A2/W45 kw 83,37 94,14 141,02 COP A2/W45 / 3,02 3,12 3,12 Heating capacity A2/W55 kw 79,21 95,24 142,66 COP A2/W55 / 2,39 2,56 2,56 Heating capacity A2/W65 kw / 96,25 144,18 COP A2/W65 / / 2,10 2,10 Heating capacity A-2/W35 kw 72,88 86,49 129,56 COP A-2/W35 / 3,32 3,44 3,44 Heating capacity A-7/W35 kw 61,22 80,59 120,72 COP A-7/W35 / 3,06 3,09 3,09 Heating capacity A-15/W35 kw 49,81 67,05 100,43 COP A-15/W35 / 2,45 2,59 2,59 Maximum outlet water temperature C Operating range C -20 C to +40 C -20 C to +40 C -20 C to +40 C Active cooling / yes yes yes Cooling capacity - reversible operation A35/W12 kw 68,4 73,6 110,4 Power input - reversible operation A35/W12 kw 31 33,4 50,1 ERR / 2,2 2,2 2,2 Neto weight - outdoor unit kg Neto weight - indoor unit kg 2 x x x 185 Dimensions of outdoor unit (W x D x H) mm 1050 x 1700 x x 1700 x x 1700 x 1530 Dimensions of indoor unit (W x D x H) mm 1233 x 1371 x x 1371 x x 1371 x 1300 Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz Noise emissions [5m] - indoor unit db Noise emissions [8m] - outdoor unit db Connecting dimensions primary side mm 2 x (22 mm / 35 mm) 2 x (22 mm / 35 mm) 3 x (22 mm / 35 mm) Connecting dimensions secondary side 1 1/2 1 1/2 1 1/2 Type of screw thread - outdoor unit / inner inner inner Air flow - primary side m 3 /h 2 x x x Nominal water flow - secondary side m 3 /h 2 x 5,1 2 x 5,7 3 x 5,7 Pressure drop - primary side kpa 2 x 0,061 2 x 0,061 3 x 0,061 Pressure drop - secondary side kpa max 20 max 20 max 20 Recommended temperature difference (flow / return) K Main connection cable dimension mm 2 5 x 25 mm 2 5 x 25 mm 2 5x25 mm 2 Power connection (indoor - outdoor unit) mm 2 2 x 3 x 1,5 mm 2 2 x 3 x 1,5 mm 2 3 x 3 x 1,5 mm 2 Electrical connection cable between indoor - outdoor unit [sheathed] mm 2 2 x 10 x 0,75 mm 2 2 x 10 x 0,75 mm 2 3 x 10 x 0,75 mm 2 Fuse / Type A 63 A / C 80 A / C 100 A / C Current nominal A 2 x 18 2 x 20,8 3 x 20,8 Current maximal A 2 x 36,3 2 x 35,9 3 x 35,9 Softstart / 2 x MCD201 2 x MCD201 3 x MCD201 Starting current A 2 x 47,52 2 x 54,91 3 x 54,91 Type of refrigerant / R407C R407C R407C Volume of refrigerant kg 2 x 12,5 2 x 14 3 x 14 Type of expansion valve / EEV EEV EEV Type of compressor / Copeland SCROLL ZH Copeland SCROLL EVI Copeland SCROLL EVI Number of compressors / Circulating pumps - return flow / no no no Fan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Back-up electrical flow heater / no no no 3-way diverting valve / no no no Serial integrated controller / Siemens RVS 21 Siemens RVS 21 Siemens RVS 21 Control of mixing heating cirquit / with extension module with extension module with extension module Control of direct heating cirquit / with extension module with extension module with extension module Solar system control / with extension module with extension module with extension module ModBus / with extension module with extension module with extension module WebControl / with WebServer module with WebServer module with WebServer module Option for cascade system / (with LPB module) (with LPB module) (with LPB module) 23
24 24 System air / water - Compact outdoor unit AEROGOR COMPACT W + DisplayBox W / ControlBox W Model name Basic solution: Aerogor Compact 25 W + DisplayBox W Aerogor Compact 36 W + DisplayBox W Aerogor Compact 44 W + DisplayBox W Aerogor Compact 54 W + DisplayBox W Aerogor Compact EVI 27 W + DisplayBox W Operating modes Heating / Cooling Heating / Cooling Heating / Cooling Heating / Cooling Heating / Cooling Model name Advanced solution: Aerogor Compact 25 W + ControlBox W Aerogor Compact 36 W + ControlBox W Aerogor Compact 44 W + ControlBox W Aerogor Compact 54 W + ControlBox W Aerogor Compact EVI 27 W + ControlBox W Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Code numbers - Aerogor Compact W Code numbers - DisplayBox W Code numbers - ControlBox W Connection between outdoor unit and heating system water pipe connection water pipe connection water pipe connection water pipe connection water pipe connection Heating capacity A7/W35 kw 25,31 35,77 44,41 53,83 25,90 COP A7/W35 / 4,64 4,77 4,64 4,77 4,79 Heating capacity A7/W45 kw 24,30 34,35 42,65 51,70 26,20 COP A7/W45 / 3,69 3,79 3,69 3,79 3,93 Heating capacity A7/W55 kw 22,95 32,43 40,27 48,82 26,68 COP A7/W55 / 2,92 3,00 2,92 3,00 3,23 Heating capacity A7/W65 kw / / / / 26,78 COP A7/W65 / / / / / 2,65 Heating capacity A2/W35 kw 20,59 29,10 36,13 43,80 22,20 COP A2/W35 / 3,60 3,70 3,60 3,70 3,70 Heating capacity A2/W45 kw 19,79 27,97 34,73 42,10 22,36 COP A2/W45 / 2,93 3,70 2,93 3,70 3,04 Heating capacity A2/W55 kw 18,81 26,58 33,00 40,00 22,62 COP A2/W55 / 2,33 2,39 2,33 2,39 2,49 Heating capacity A2/W65 kw / / / / 22,86 COP A2/W65 / / / / / 2,05 Heating capacity A-2/W35 kw 17,30 24,45 30,36 36,80 20,54 COP A-2/W35 / 3,23 3,32 3,23 3,32 3,35 Heating capacity A-7/W35 kw 14,53 20,45 25,50 30,92 19,14 COP A-7/W35 / 2,98 3,06 2,98 3,06 3,01 Heating capacity A-15/W35 kw 11,82 16,71 20,75 25,15 15,93 COP A-15/W35 / 2,39 2,45 2,39 2,45 2,52 Maximum outlet water temperature C Operating range C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C Active cooling / yes yes yes yes yes Cooling capacity - reversible operation A35/W12 kw 16,50 23,30 28,20 34,20 18,60 Power input - reversible operation A35/W12 kw 7,10 10,10 12,80 15,50 8,00 ERR / 2,3 2,3 2,2 2,2 2,3 Neto weight - outdoor unit kg Neto weight - indoor unit kg Dimensions of outdoor unit (W x D x H) mm 1345 x 930 x x 1371 x x 1371 x x 1371 x x 1371 x 1246 Dimensions of indoor unit (W x D x H) mm 535 x 350 x x 350 x x 350 x x 350 x x 350 x 590 Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz Noise emissions [5m] - indoor unit db Noise emissions [8m] - outdoor unit db Connecting dimensions secondary side 1 1/4 1 1/2 1 1/2 1 1/2 1 1/4 Type of screw thread - outdoor unit / inner inner inner inner inner Air flow - primary side m 3 /h Nominal water flow - secondary side m 3 /h 3,20 4,60 4,10 5,10 3,90 Pressure drop - primary side kpa 0,05 0,057 0,043 0,061 0,057 Pressure drop - secondary side kpa max 20 max 20 max 20 max 20 max 20 Recommended temperature difference (flow / return) K Main connection cable dimension mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 10 mm 2 5 x 6 mm 2 Power connection (indoor - outdoor unit) mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 10 mm 2 5 x 6 mm 2 Electrical connection cable between indoor - outdoor unit [sheathed] mm 2 UTP & 5 x 0,75 mm 2 UTP & 5 x 0,75 mm 2 UTP & 5 x 0,75 mm 2 UTP & 5 x 0,75 mm 2 UTP & 5 x 0,75 mm 2 Fuse / Type A 32 A / C 25 A / C 32 A / C 40 A / C 32 A / C Current nominal A 11,60 11,80 16,80 18,00 11,80 Current maximal A 27,90 23,90 28,90 36,30 29,90 Softstart / MCI 25 MCI 25 MCD201 MCD201 MCI 25 Starting current A 30,62 31,15 44,35 47,52 31,15 Type of refrigerant / R407C R407C R407C R407C R407C Volume of refrigerant kg 7,00 7,30 12,00 12,50 8,20 Type of expansion valve / EEV EEV EEV EEV EEV Type of compressor / Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL EVI Number of compressors / Circulating pumps - return flow / yes yes yes yes yes Fan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Back-up electrical flow heater / no no no no no 3-way diverting valve / no no no no no Serial integrated controller / Siemens RVS 21 Siemens RVS 21 Siemens RVS 21 Siemens RVS 21 Siemens RVS 21 Control of mixing heating cirquit / with extension module with extension module with extension module with extension module with extension module Control of direct heating cirquit / yes yes yes yes yes Solar system control / with extension module with extension module with extension module with extension module with extension module ModBus / with extension module with extension module with extension module with extension module with extension module WebControl / with WebServer module with WebServer module with WebServer module with WebServer module with WebServer module Option for cascade system / (with LPB module) (with LPB module) (with LPB module) (with LPB module) (with LPB module)
25 System air / water - Compact outdoor unit AEROGOR COMPACT W + DisplayBox W / ControlBox W Model name Basic solution: Aerogor Compact EVI 37 W + DisplayBox W Aerogor Compact EVI 48 W + DisplayBox W Aerogor Compact EVI 56 W + DisplayBox W Operating modes Heating / Cooling Heating / Cooling Heating / Cooling Model name Advanced solution: Aerogor Compact EVI 37 W + ControlBox W Aerogor Compact EVI 48 W + ControlBox W Aerogor Compact EVI 56 W + ControlBox W Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Code numbers - Aerogor Compact W Code numbers - DisplayBox W Code numbers - ControlBox W Connection between outdoor unit and heating system water pipe connection water pipe connection water pipe connection Heating capacity A7/W35 kw 35,58 47,13 54,95 COP A7/W35 / 4,79 4,91 4,91 Heating capacity A7/W45 kw 36,00 47,68 55,59 COP A7/W45 / 3,93 4,04 4,04 Heating capacity A7/W55 kw 36,66 48,56 56,61 COP A7/W55 / 3,23 3,31 3,31 Heating capacity A7/W65 kw 36,80 48,74 56,83 COP A7/W65 / 2,65 2,72 2,72 Heating capacity A2/W35 kw 30,50 40,40 47,10 COP A2/W35 / 3,70 3,80 3,80 Heating capacity A2/W45 kw 30,72 40,69 47,44 COP A2/W45 / 30,40 3,12 3,12 Heating capacity A2/W55 kw 31,08 41,17 48,00 COP A2/W55 / 2,49 2,56 2,56 Heating capacity A2/W65 kw 31,41 41,61 48,51 COP A2/W65 / 2,05 2,10 2,10 Heating capacity A-2/W35 kw 28,23 37,39 43,59 COP A-2/W35 / 3,35 3,44 3,44 Heating capacity A-7/W35 kw 26,30 34,84 40,62 COP A-7/W35 / 3,01 3,09 3,09 Heating capacity A-15/W35 kw 21,88 28,98 33,79 COP A-15/W35 / 2,52 2,59 2,59 Maximum outlet water temperature C Operating range C -20 C to +40 C -20 C to +40 C -20 C to +40 C Active cooling / yes yes yes Cooling capacity - reversible operation A35/W12 kw 23,90 31,80 36,80 Power input - reversible operation A35/W12 kw 10,80 13,80 16,70 ERR / 2,2 2,3 2,2 Neto weight - outdoor unit kg Neto weight - indoor unit kg Dimensions of outdoor unit (W x D x H) mm 1776 x 1371 x x 1371 x x 1371 x 1246 Dimensions of indoor unit (W x D x H) mm 535 x 350 x x 350 x x 350 x 590 Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz Noise emissions [5m] - indoor unit db Noise emissions [8m] - outdoor unit db Connecting dimensions secondary side 1 1/2 1 1/2 1 1/2 Type of screw thread - outdoor unit / inner inner inner Air flow - primary side m 3 /h Nominal water flow - secondary side m 3 /h 5,20 4,80 5,70 Pressure drop - primary side kpa 0,075 0,043 0,061 Pressure drop - secondary side kpa max 20 max 20 max 20 Recommended temperature difference (flow / return) K Main connection cable dimension mm 2 5 x 6 mm 2 5 x 10 mm 2 5 x 10 mm 2 Power connection (indoor - outdoor unit) mm 2 5 x 6 mm 2 5 x 10 mm 2 5 x 10 mm 2 Electrical connection cable between indoor - outdoor unit [sheathed] mm 2 UTP & 5 x 0,75 mm 2 UTP & 5 x 0,75 mm 2 UTP & 5 x 0,75 mm 2 Fuse / Type A 32 A / C 32 A / C 40 A / C Current nominal A 14,60 16,80 20,80 Current maximal A 27,10 30,60 35,90 Softstart / MCI 25 MCD201 MCD201 Starting current A 38,54 44,35 51,91 Type of refrigerant / R407C R407C R407C Volume of refrigerant kg 9,50 13,00 14,00 Type of expansion valve / EEV EEV EEV Type of compressor / Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVI Number of compressors / Circulating pumps - return flow / yes yes yes Fan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Back-up electrical flow heater / no no no 3-way diverting valve / no no no Serial integrated controller / Siemens RVS 21 Siemens RVS 21 Siemens RVS 21 Control of mixing heating cirquit / with extension module with extension module with extension module Control of direct heating cirquit / yes yes yes Solar system control / with extension module with extension module with extension module ModBus / with extension module with extension module with extension module WebControl / with WebServer module with WebServer module with WebServer module Option for cascade system / (with LPB module) (with LPB module) (with LPB module) 25
26 26 Split system air / water : outdoor unit + indoor unit AEROGOR SPLIT AW W and SPLIT AW EVI W Model name Aerogor Split AW 25 W Aerogor Split AW 36 W Aerogor Split AW 44 W Aerogor Split AW 54 W Aerogor Split AW 47 EVI W Aerogor Split AW 55 EVI W Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Code number / / / / / / Connection between outdoor and indoor unit Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Heating capacity A7/W35 kw 25,31 35,77 44,41 53,83 47,13 54,95 COP A7/W35 / 4,64 4,77 4,64 4,77 4,91 4,91 Heating capacity A7/W45 kw 24,30 34,35 42,65 51,70 47,68 55,59 COP A7/W45 / 3,69 3,79 3,69 3,79 4,04 4,04 Heating capacity A7/W55 kw 22,95 32,43 40,27 48,83 48,56 56,61 COP A7/W55 / 2,92 3,00 2,92 3,00 3,31 3,31 Heating capacity A7/W65 kw / / / / 48,74 56,83 COP A7/W65 / / / / / 2,72 2,72 Heating capacity A2/W35 kw 20,59 29,10 36,13 43,80 40,40 47,10 COP A2/W35 / 3,60 3,70 3,60 3,70 3,80 3,80 Heating capacity A2/W45 kw 19,79 27,97 34,73 42,10 40,69 47,44 COP A2/W45 / 2,93 3,02 2,93 3,02 3,12 3,12 Heating capacity A2/W55 kw 18,81 26,58 33,00 40,00 41,17 48,00 COP A2/W55 / 2,33 2,39 2,33 2,39 2,56 2,56 Heating capacity A2/W65 kw / / / / 41,61 48,51 COP A2/W65 / / / / / 2,10 2,10 Heating capacity A-2/W35 kw 17,30 24,45 30,36 36,80 37,39 43,59 COP A-2/W35 / 3,23 3,32 3,23 3,32 3,44 3,44 Heating capacity A-7/W35 kw 14,53 20,54 25,50 30,92 34,84 40,62 COP A-7/W35 / 2,98 3,06 2,98 3,06 3,09 3,09 Heating capacity A-15/W35 kw 11,82 16,71 20,75 25,15 28,98 33,79 COP A-15/W35 / 2,39 2,45 2,39 2,45 2,59 2,59 Maximum outlet water temperature C Operating range C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C Active cooling / yes yes yes yes yes yes Cooling capacity - reversible operation A35/W12 kw 16,5 23,3 28,2 34,2 31,8 36,8 Power input - reversible operation A35/W12 kw 7,1 10,1 12,8 15,5 13,8 16,7 ERR / 2,3 2,3 2,2 2,2 2,3 2,2 Neto weight - outdoor unit kg Neto weight - indoor unit kg Dimensions of outdoor unit (W x D x H) mm 800 x 580 x x 580 x x 785 x x 785 x x 785 x x 785 x 1105 Dimensions of indoor unit (W x D x H) mm 800 x 900 x x 1290 x x 1290 x x 1290 x x 1290 x x 1290 x 1045 Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz Noise emissions [5m] - indoor unit db Noise emissions [8m] - outdoor unit db Connecting dimensions primary side mm 16 mm / 28 mm 18 mm / 28 mm 18 mm / 35 mm 22 mm / 35 mm 18mm / 35mm 22 mm / 35 mm Connecting dimensions secondary side 1 1/4 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 Type of screw thread - outdoor unit / inner inner inner inner inner inner Air flow - primary side m 3 /h Nominal water flow - secondary side m 3 /h 3,2 4,6 4,1 5,1 4,8 5,7 Pressure drop - primary side kpa 0,05 0,057 0,043 0,061 0,043 0,061 Pressure drop - secondary side kpa max 20 max 20 max 20 max 20 max 20 max 20 Recommended temperature difference (flow / return) K Main connection cable dimension mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 10 mm 2 5 x 10 mm 2 5 x 10 mm 2 Power connection (indoor - outdoor unit) mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 Electrical connection cable between indoor - outdoor unit [sheathed] mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 Fuse / Type A 32 A / C 25 A / C 32 A / C 40 A / C 32 A / C 40 A / C Current nominal A 11,6 11,8 16, ,8 20,8 Current maximal A 27,9 23,9 28,9 36,3 30,6 35,9 Softstart / MCI 25 MCI 25 MCD201 MCD201 MCD201 MCD201 Starting current A 30,62 31,15 44,35 47,52 44,35 54,91 Type of refrigerant / R407C R407C R407C R407C R407C R407C Volume of refrigerant kg 7 7, , Type of expansion valve / EEV EEV EEV EEV EEV EEV Type of compressor / Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL EVI Copeland SCROLL EVI Number of compressors / Circulating pumps - return flow / yes yes yes yes yes yes Fan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Back-up electrical flow heater / no no no no no no 3-way diverting valve / no no no no no no Serial integrated controller / Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Control of mixing heating cirquit / yes yes yes yes yes yes Control of direct heating cirquit / yes yes yes yes yes yes Solar system control / yes yes yes yes yes yes ModBus / with extension module with extension module with extension module with extension module with extension module with extension module WebControl / z Web modulom z Web modulom z Web modulom z Web modulom with WebServer module with WebServer module Option for cascade system / (with LPB module) (with LPB module) (with LPB module) (with LPB module) (with LPB module) (with LPB module)
27 Split system air / water : outdoor unit + indoor unit AEROGOR SPLIT AW W and SPLIT AW EVI W Model name Aerogor Split AW 20 EVI W Aerogor Split AW 26 EVI W Aerogor Split AW 36 EVI W Aerogor Split AW 47 EVI W Aerogor Split AW 55 EVI W Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Code number / / / / / Connection between outdoor and indoor unit Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Heating capacity A7/W35 kw 19,95 25,90 35,58 47,13 54,95 COP A7/W35 / 4,91 4,79 4,79 4,91 4,91 Heating capacity A7/W45 kw 20,18 26,20 36,00 47,68 55,59 COP A7/W45 / 4,04 3,93 3,93 4,04 4,04 Heating capacity A7/W55 kw 20,55 26,68 36,66 48,56 56,61 COP A7/W55 / 3,31 3,23 3,23 3,31 3,31 Heating capacity A7/W65 kw 20,63 26,78 36,80 48,74 56,83 COP A7/W65 / 2,72 2,65 2,65 2,72 2,72 Heating capacity A2/W35 kw 17,10 22,20 30,50 40,40 47,10 COP A2/W35 / 3,80 3,70 3,70 3,80 3,80 Heating capacity A2/W45 kw 17,22 22,36 30,72 40,69 47,44 COP A2/W45 / 3,12 3,04 3,04 3,12 3,12 Heating capacity A2/W55 kw 17,43 22,62 31,08 41,17 48,00 COP A2/W55 / 2,56 2,49 2,49 2,56 2,56 Heating capacity A2/W65 kw 17,61 22,86 31,41 41,61 48,51 COP A2/W65 / 2,10 2,05 2,05 2,10 2,10 Heating capacity A-2/W35 kw 15,82 20,54 28,23 37,39 43,59 COP A-2/W35 / 3,44 3,35 3,35 3,44 3,44 Heating capacity A-7/W35 kw 14,75 19,14 26,30 34,84 40,62 COP A-7/W35 / 3,09 3,01 3,01 3,09 3,09 Heating capacity A-15/W35 kw 12,27 15,93 21,88 28,98 33,79 COP A-15/W35 / 2,59 2,52 2,52 2,59 2,59 Maximum outlet water temperature C Operating range C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C -20 C to +40 C Active cooling / yes yes yes yes yes Cooling capacity - reversible operation A35/W12 kw 14,6 18,6 23,9 31,8 36,8 Power input - reversible operation A35/W12 kw 6,6 8 10,8 13,8 16,7 ERR / 2,2 2,3 2,2 2,3 2,2 Neto weight - outdoor unit kg Neto weight - indoor unit kg Dimensions of outdoor unit (W x D x H) mm 600 x 580 x x 580 x x 580 x x 785 x x 785 x 1105 Dimensions of indoor unit (W x D x H) mm 800 x 900 x x 1290 x x 1290 x x 1290 x x 1290 x 1045 Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz Noise emissions [5m] - indoor unit db Noise emissions [8m] - outdoor unit db Connecting dimensions primary side mm 12 mm / 22 mm 16 mm / 28 mm 16mm / 28mm 18mm / 35mm 22 mm / 35 mm Connecting dimensions secondary side 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 Type of screw thread - outdoor unit / inner inner inner inner inner Air flow - primary side m 3 /h Nominal water flow - secondary side m 3 /h 3 3,9 5,2 4,8 5,7 Pressure drop - primary side kpa 0,05 0,057 0,075 0,043 0,061 Pressure drop - secondary side kpa max 20 max 20 max 20 max 20 max 20 Recommended temperature difference (flow / return) K Main connection cable dimension mm 2 5 x 4 mm 2 5 x 6 mm 2 5 x 6 mm 2 5 x 10 mm 2 5 x 10 mm 2 Power connection (indoor - outdoor unit) mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 3 x 1,5 mm 2 Electrical connection cable between indoor - outdoor unit [sheathed] mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 10 x 0,75 mm 2 Fuse / Type A 25 A / C 32 A / C 32 A / C 32 A / C 40 A / C Current nominal A 9,7 11,8 14,6 16,8 20,8 Current maximal A 25,5 29,9 27,1 30,6 35,9 Softstart / MCI 15 MCI 25 MCI 25 MCD201 MCD201 Starting current A 25,6 31,15 38,54 44,35 54,91 Type of refrigerant / R407C R407C R407C R407C R407C Volume of refrigerant kg 5,9 8,2 9, Type of expansion valve / 4.5 (12/16) EEV EEV EEV EEV Type of compressor / Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVI Number of compressors / Circulating pumps - return flow / yes yes yes yes yes Fan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Back-up electrical flow heater / yes, 3 x 2kW no no no no 3-way diverting valve / yes no no no no Serial integrated controller / Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Control of mixing heating cirquit / yes yes yes yes yes Control of direct heating cirquit / yes yes yes yes yes Solar system control / yes yes yes yes yes ModBus / with extension module with extension module with extension module with extension module with extension module WebControl / with WebServer module with WebServer module with WebServer module with WebServer module with WebServer module Option for cascade system / (with LPB module) (with LPB module) (with LPB module) (with LPB module) (with LPB module) 27
your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps
Follow our Green Tree heat pumps heat pumps manufacturer Green Join the Hotjet Green Tree your tree for you Line project, let us plant By purchasing the first heat pump in the HOTJET Green Tree product
More informationAIRLINE - commercial heat pumps Air / water heat pump for heating, cooling and DHW production - commercial use
S m a r t h e a t i n g s o l u t i o n s AIRLINE - commercial heat pumps Air / water heat pump for heating, cooling and DHW production - commercial use EFFICIENT SOLUTION with EASY OPERATION COP 4.62*
More information> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base
More informationHEAT PUMPS LINE AS AIR TO WATER
HET PUMPS LINE S IR TO WTER EROGOR ECO INVERTER LL-IN-ONE EROGOR ECO INVERTER EROGOR POWER EVI INVERTER SUPER PERFORMNCE Heating Cooling Domestic hot water SUPER DVNTGE Wifi module included Big touch screen
More informationPRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.
PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION
More informationV018-EN-02 AIR TO WATER HEAT PUMPS 2019 HEART OF YOUR HOME
V018-EN-02 AIR TO WATER HEAT PUMPS 2019 HEART OF YOUR HOME H E A T P U M P S Air To Water Heat Pumps Nowadays, people are becoming increasingly focused on the costs of heating as well as on environmental
More informationTechnical data LA 60TU
Technical data LA 6TU Device information LA 6TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance
More informationTechnical data LA 9S-TU
Technical data LA 9S-TU Device information LA 9S-TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance
More informationTechnical data LA 28TBS
Technical data LA 28TBS Device information LA 28TBS Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance
More informationStarting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)
Data sheet LA 16MS Air-to-water heat pump with deflector hoods Max. flow temperature: 58 C Casing colour: White aluminium (similar to RAL 9006) Air-to-water heat pump for outdoor installation with external
More informationECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.
ECOFOREST GEOTERMIA www.ecoforest.es comercial.geotermia@ecoforest.es Ground/Air Source Heat Pumps ecogeo ECOFOREST GEOTERMIA New company, 2010, Ecoforest Geotermia Manufacture of ground/air source heat
More informationAdvance Split
Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.
More informationHeating with airborne and geothermal energy making the best possible use of renewables
Heat pumps 2/3 Heating with airborne and geothermal energy making the best possible use of renewables This brochure provides detailed information on sustainable and environmentally responsible heat generation
More informationV016-EN-01 AIR TO WATER HEAT PUMPS 2016 HEART OF YOUR HOME
V016-EN-01 AIR TO WATER HEAT PUMPS 2016 HEART OF YOUR HOME H E A T P U M P S Air To Water Heat Pumps Nowadays, people are becoming increasingly focused on the costs of heating as well as on environmental
More informationEVI Scroll Air To Water Heat Pumps
AIR TO WATER HEAT PUMPS 2013 heart of your home H E A T P U M P S Air To Water Heat Pumps Nowadays, people are increasingly focusing on the costs of heating as well as on environmental issues. Traditional
More informationV017-EN-01 AIR TO WATER HEAT PUMPS HEART OF YOUR HOME
V017-EN-01 AIR TO WATER HEAT PUMPS 2017-2018 HEART OF YOUR HOME H E A T P U M P S Air To Water Heat Pumps Nowadays, people are becoming increasingly focused on the costs of heating as well as on environmental
More informationGeolo THE GROUND SOURCE HEAT PUMP PLUSES
Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar
More informationTechnical data LA 60TUR+
Technical data LA 6TUR+ Device information LA 6TUR+ Design - Heat source Outside air - Model Universal design reversible - Regulation - Thermal energy metering Integrated - Installation location Outdoors
More informationStarting current with soft starter Fuse protection
Data sheet LIH 26TE High temperature air-to-water heat pump Max. flow temperature: 75 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for
More informationTechnical data. Danfoss DHP-L
Technical data Danfoss DHP-L Heat pump with the same features as Danfoss DHP-H, but with separate hot water tank. Can reduce heating costs by more than 50 percent. Main parts... 2 Bipack contents... 3
More informationHeat pumps. Heating systems Industrial systems Refrigeration systems
Heat pumps Heating systems Industrial systems Refrigeration systems 2/3 Heating with airborne and geothermal heat making the best possible use of renewables This brochure provides detailed information
More informationPHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW
TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationCHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw
TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential
More informationData sheet SI 24TE. Brine-to-water heat pump with two performance levels
Data sheet SI 24TE Brine-to-water heat pump with two performance levels Order reference: SI 24TE Installation location: Indoors Flow temperature max 60 C Casing, powder-coated Heat pump for heating purposes
More informationCZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or
More informationNatural geothermal energy
Natural geothermal energy ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient. L A ++ A Scale space heating
More informationHITACHI line up: YUTAKI S 80 Very high water temperature Heat Pump
HITACHI line up: YUTAKI S 80 Very high water temperature Heat Pump Chauffage & Climatisation Hitachi Air Conditionning Europe SAS YUTAKI S80 Introduction: Why a very High temperature heat pump 1) Yutaki
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating
More informationNatural Heat VITOCAL 300-A VITOCAL 350-A. Air source heat pumps
Natural Heat VITOCAL 300-A VITOCAL 350-A Air source heat pumps Heat pumps Vitocal 300-A Vitocal 300-A is certified in accordance with the EHPA heat pump quality seal and NF-PAC. Top technology for top
More informationINVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.
LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2017 LG Electronics. All rights reserved. FEATURES & BENEFITS High Efficient Inverter Technologies EER 2.65 / COP 3.2 /
More informationPRODUCT RANGE HEAT PUMPS 2012
PRODUCT RANGE HEAT PUMPS 2012 TABLE OF CONTENTS Product range...4 Heat pump system benefits...6 Is the heat pump considered as a "RENEWABLE SOURCE"?...8 ENERGETIC advantage of the heat pump...10 ECONOMIC
More informationPRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.
PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 00 m /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION
More informationTOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS
TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and
More informationAIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw
COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,
More informationH4T R410A. refrigerant
H4T INDEX Polyvalent unit working modes...pag. 4 Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag.
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More informationPress. Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity
Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity What s new at a glance: - This year, Viessmann is launching a whole new series of innovative air/water heat pumps
More informationHeat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications
Heat Pump Technology Air Source, Water Source and Ground Source Optimised heat pumps for residential and commercial applications ICS Cool Energy Limited has nearly 25 years experience in supplying and
More informationNIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump
NIBE F1355 Ground source heat pump Speed-controlled ground source heat pump for large buildings Optimal annual coefficient of performance and minimal operating costs thanks to the inverter controlled compressor.
More informationOilon Ground Source Heat Pumps
Oilon Ground Source Heat Pumps Homes - Large properties - Industry Ground source heat pump Oilon CUBE For properties 90-400 m² Extremely high domestic hot water production The Oilon CUBE ground source
More informationINVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by
4mm 이상 ~ 15mm 미만 (음화형 규정) LG Electronics http://www.lg.com http://partner.lge.com Copyright 2017 LG Electronics. All rights reserved. Distributed by FEATURES & BENEFITS High Efficient Inverter Technologies
More informationRefrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions
TECHNICAL DATA SHEET HP08L-M-WEB Performance Data 1) A-7W35 A2W35 A10W35 A2W50 Heating capacity 8,67 kw 11,14 kw 14,91 kw 9,87 kw Cooling capacity 6,16 kw 8,58 kw 12,33 kw 6,43 kw Input 2,51 kw 2,56 kw
More informationVIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O
VIESMANN VITOCAL Air/water heat pumps Technical guide VITOCAL 300-A Type AWC-I and AW-O Up to 60 C flow temperature Modulating output range 3 to 9 kw Reversible air source heat pump with electric drive
More informationSA 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser coils...pag. 6 Brazed
More informationNABILATON PRO. The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton.
NABILATON PRO NABILATON PRO KIT The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton. INVERTER TECHNOLOGY Increasing the compressor motor rotation
More informationDimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference
Data sheet LI 9TU High efficiency air-to-water heat pump for indoor installation. Max. flow temperature: 60 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for
More informationS-Therm Air to Water Heat Pumps
S-Therm Air to Water Heat Pumps AIR TO WATER HEAT PUMP Air to water heat pump Nowadays, people are increasingly focusing on the cost of heating as well as on environmental issues. Traditional heating systems
More informationStarting current with soft starter Fuse protection. Heat source connection
Data sheet SI 17TE Brine-to-water heat pump max. flow temperature: 58 C Casing colour: white Brown-red design screen (RAL 3011) Heat pump for indoor installation with integrated regulation WPM 2007 plus.
More informationHeating with airborne and geothermal heat
Heating with airborne and geothermal heat 2/3 Heating with airborne and geothermal heat making the best possible use of renewables This brochure provides detailed information on sustainable and environmentally
More informationNEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com
NEOSYS AIR TO WATER LIQUID CHILLER 200-1000 kw AIR TO WATER HEAT PUMP 200-500 kw lennoxemea.com NEOSYS, winning ENERGY PERFORMANCE The NEOSYS delivers energy efficiency at full and partial load by the
More informationStarting current with soft starter Fuse protection
Data sheet SI 14ME Brine-to-water heat pump Max. flow temperature: 58 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for indoor installation
More informationWZH Ground source heat pumps
Ground source heat pumps infolinia: +48 691 262 691 +60 C C.O.P. 5,1 HP heat pumps are particularly suitable for applications that utilise well water or ground source probes. These units have been designed
More informationWHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES
Ground source heat pumps +60 C C.O.P. 5,1 heat pumps are particularly suitable for applications that utilise ground source probes.these units have been designed for use with radiant floor heating systems
More informationType summary Albatros 2
OEM Type summary lbatros 2 The lbatros 2 family is a comprehensive range of controls. It offers solutions for basic to complex heating plant. Uniform and integral operating philosophy with clear-text display
More informationSUMMARY. S-THERM+, S-THERM and SWH technology. S-THERM+ introduction. S-THERM indoor unit. S-THERM outdoor unit. S-THERM+ control
HEAT PUMPS 2014 heart of your home H E A T P U M P S SUMMARY S-THERM+, S-THERM and SWH technology S-THERM+ introduction S-THERM+ indoor unit S-THERM+ outdoor unit S-THERM+ control S-THERM+ hydraulic scheme
More informationWHY A MHI HEAT PUMP?
HYDROLUTION HEATING HOT SANITARY WHY A MHI HEAT PUMP? Mitsubishi Heavy Industries Thermal Systems air to water heat pump is a complete modern system for heating, cooling and producing hot sanitary water
More informationHeating with natural heat
Heating with natural heat 2/3 Heat pumps: Heating and cooling with natural energy The purpose of this brochure is to give you detailed information about one of the most futureproof and environmentally
More information50A KP 70A KP 90A KP 120A KP 150A KP 210A
DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw
More informationGround Source Heat Pumps
indoor installation Ground Source Heat Pumps heat pumps The heat pump specialist indoor installation Ground Source Heat Pumps heat pumps The heat pump specialist AlphaWeb compatible Simply control your
More informationLZA High efficiency air to water heat pumps with HP compressor
High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationWDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES
Ground source heat pumps +60 C C.O.P. 5,1 heat pumps are particularly suitable for applications that utilise ground source probes.these units have been designed for use with radiant floor heating systems
More informationLEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS
Total heat recovery multi-purpose units LEP Indoor monobloc water-water unit LEP 50-40 kw Maximum efficiency with total recovery and dissipation in water. Total heat recovery multi-purpose unit Multi-purpose
More informationDo you want a versatile solution
Do you want a versatile solution to make significant savings? ESTIA TOSHIBA AIR CONDITIONING RESIDENTIAL HEATING AIR-TO-WATER HEAT PUMP ESTIA hatever you need ESTIA TO MAKE SIGNIFICANT SAVINGS Toshiba
More informationTechnical description. Atec.
www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.
More informationLCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS
Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose
More informationTHE HEART OF YOUR COMFORT
S m a r t h e a t i n g s o l u t i o n s THE HEART OF YOUR COMFORT Efficient DHW heating solution. PREMIUM BRAND SLO/EU MADE 25 YEARS 50.000 COMPREHENSIVE SOLUTIONS CUSTOMERS More than 50.000 satisfied
More informationEfficient heating that won t cost the earth
Product Range Guide Efficient heating that won t cost the earth CTC is an international manufacturer of innovative renewable heating solutions. For over 90 years our ranges of high performance products
More informationHEAT PUMPS EN - flyer 10/p/2017 Made in Poland
HEAT PUMPS EN - flyer 0/p/07 Made in Poland www.galmet.eu A + Spectra 60 AIR SOURCE HEAT PUMP WATER HEATER T E C H N O L O G I A FOR DHW - spectra AND spectra smart Spectra Smart heat pumps Convenient
More informationTechnical Information
Date of last update: May-12 Ref: : Application Engineering Europe ENHANCED VAPOUR INJECTION (EVI) FOR ZH*KVE SCROLL COMPRESSORS 1 Introduction... 2 2 Principle of operation... 2 3 Capacity effect... 3
More informationAquaflair TRAC-TRAF-TRAH
Aquaflair TRAC-TRAF-TRAH 110 400 kw Air-cooled chillers, free-cooling chillers and heat pumps for mission critical applications Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors
More informationPlanning guide. Atec.
www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.
More informationLG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
More informationHeat pump systems and Chillers
PRODUCT OVERVIEW Heat pump systems and Chillers HIdROS was formed in 1993 as a distribution company operating in the humidification and dehumidification sector of the air conditioning market. The expansion
More information- cooling operation - built-in heat meter - electronic circulating pumps
-PN Brine to Water heat pump with domestic hot water tank 4,6-10,9 kw with R407c refrigerant The HAUTEC series may be used in conjunction with different heat sources such as geothermal probes or geothermal
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationAIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round
AIR TO WATER HEAT PUMPS Hot water and comfortable ambient temperature all year round HEAT PUMP PRINCIPLE CARRIER. A UNITED TECHNOLOGIES COMPANY Whether you need air conditioning for a new building or a
More informationControl Products & Systems OEM
LMS The modular management system for condensing boilers Control Products & Systems OEM www.siemens.com/buildingtechnologies-oem LMS advanced electronics and proven software At times of dwindling resources,
More informationPRODUCT LINEUP AIR TO WATER. For RESIDENTIAL. Room Heating & Cooling
PRODUCT LINEUP AIR TO WATER For RESIDENTIAL Room Heating & Cooling 238 Complete Solution meets various needs The clean energy produced by WATERSTAGE reliably delivers comfort to all spaces in the home
More informationPRODUCT GUIDE
PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency
More informationLG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
More informationprestige Control Application Supplement - TriMax
prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions
More informationnemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING
171 water cooled chillers / heat pumps and motoevaporating units COOLING HEATING R410A 1 96 3 2 0 1 3 f i f t y c o o l y e a r s RCGROUP SpA 19632013 fiftycoolyears PLATE 5,4 30,5 kw 6,4 37,4 kw 172 VERSIONS
More informationA2/W35: 8.6kW, Power consumption: 2.39kW, COP 3,6. A2/W35: 10.1kW, Power consumption: 2,8kW, COP 3,6
Heat pumps Air-Water Hotjet I 10 Hotjet 11i A2/W35: 8.6kW, ower consumption: 2.39kW, CO 3,6 20 Hotjet 15i A2/W35: 10.1kW, ower consumption: 2,8kW, CO 3,6 Hotjet 8i A2/W35: 7.2kW, ower consumption: 2,01kW,
More informationHeat Pumps. ground-to-water models air-to-water models. Energy-saving solutions
Heat Pumps ground-to-water models air-to-water models www.regulus.eu 2 Heat Pumps CONTENTS 5 Heat Pump Q&A 6 How does it work? 7 Where does a Heat Pump take energy from? 9 EcoAir 406-420 Air-to-Water Heat
More informationAir cooled industrial chillers
Air cooled industrial chillers Main features R410A refrigerant Cooling capacity 5 175 kw Air cooled industrial chillers Models Versions HE High Efficiency Finned coil evaporators submerged in the storage
More informationHEAT PUMPS AQUAGOR G / TERRAGOR G / AEROGOR SPLIT G 55/62 C -20 C
HT PUMPS QUOR / TRROR / ROOR SPLIT /62-20 2 INTROUTION closer look at nature reveals new technologies for a cosy and warm home. Heat is energy, and energy is all around us. Nature is one of the key resources
More information80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features
Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationBRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.
More information
Mobile Heating System K e - for high comfort and remote control. HEYLO All Rights Reserved. EXPERT FOR PROFESSIONALS
Mobile Heating System K 160 - e - for high comfort and remote control The Advantages for your customer at a glance Higher comfort Lower Energy consumption More Information Better service Exchanger-burner-ventilator
More information30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient
PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme
More informationAir / Water Heat Pump - Compact Design Modulating 8 18 kw
Air Ground Water Air / Water Heat Pump - Compact Design Modulating 8 18 kw Heliotherm Sensor Comfort Compact A modulating air / water heat pump in compact design for outdoor installation for generous sized
More informationAir to water Heat Pump System
Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a
More informationEVI + INVERTER MODELS A Q U A P U R A
W W W L V P R E N E W A B L E S I E A Q U A P U R A H E A T I N G & C O O L I N G AIR TO WATER HEAT PUMPS A++ 35ºC A+ 55ºC EVI + INVERTER MODELS REPLACE YOUR OIL / GAS BOILER IDEAL FOR UNDERFLOOR HEATING
More informationTechnical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating
Technical Data Danfoss DHP-C Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating costs A built in 180 litre water tank Main parts... 2 Bipack contents...
More informationTechnical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
More informationCONTENT. S-THERM+, S-THERM and SWH technology. S-THERM+ introduction. S-THERM indoor unit. S-THERM outdoor unit. S-THERM+ control
HEAT PUMPS 2015 heart of your home H E A T P U M P S CONTENT S-THERM+, S-THERM and SWH technology S-THERM+ introduction S-THERM+ indoor unit S-THERM+ outdoor unit S-THERM+ control S-THERM+ hydraulic scheme
More informationBWL air heat pumps BWS brine heat pumps
BWL air heat pumps BWS brine heat pumps Wolf - Heat pumps Benefits offered by Wolf heat pumps From each 1 kwh power, heat pumps generate between 3 and 5 kwh heat Free environmental energy from the ground
More informationfood-retail.danfoss.com Overview Brochure ADAP-KOOL Evaporator Controllers Achieve best-in-class energy efficiency and food safety
Overview Brochure ADAP-KOOL Evaporator s Achieve best-in-class energy efficiency and food safety Proven solutions based on 30 years of experience food-retail.danfoss.com Robust, Easy & Intelligent From
More information