Fan Coil Unit (FCU) Application Guide
|
|
- Amie Casey
- 6 years ago
- Views:
Transcription
1 Fan Coil Unit (FCU) Series Room Controllers TABLE OF CONTENTS and SCs Fan coil terminal equipment controllers 2 A VC3500E5000: Heating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves with wireless door switch 4 VTR8350A5000 -VC3404E5000: Cooling and electric heat: 2-pipe fan coil unit with 3-speed fan, dehumidification, 2-position valves 6 A VC3504E5000: Heating/cooling with changeover sensor: 2-pipe fan coil unit with 3-speed fan and wireless window switch 8 VTR8350A VC3400E5000: Cooling and electric heat: 2-pipe fan coil unit with 3-speed fan and dehumidification, 2-position valves 10 A VC3514E5000: Heating/cooling: 2-pipe fan coil unit with 3-speed fan and fresh air damper, 2-position valves 12 A5000 -VC3500E5000 -VC3300E5000: Heating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves with slave relay pack 14 A VC3504E5000: Cooling and electric heat: 2-pipe fan coil unit with 3-speed fan, 2-position valves with wired window switch 16 A VC3500E5000: Heating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves with wired door switch 18 Appendix A - Passive infra-red (PIR) motion detector cover specifications 20 Appendix B - option network wiring if communicating models are used 21 Appendix C - controllers occupancy sequence of operation schematic 21 Appendix D - SED Series - wireless door & window switch 22 Appendix E - controller & VC3000 relay pack 23
2 2 Fan Coil Controller OVERVIEW & Relay Pack This new cost-effective solution for upgrading line-voltage fan coil unit thermostats requires only two components: the terminal equipment controller and the SC3000 relay pack. This solution allows existing line voltage wiring between the fan coil unit and temperature controller to be re-used, reducing overall costs and installation time. The SC3000 relay pack features an onboard universal voltage power supply and line-voltage relays which directly drive fractional horsepower fan motors and valves. This eliminates the need to install and wire costly pilot relays and transformers. The Line Voltage Fan Coil Terminal Equipment Controller and SC3000 Relay Pack can be configured to handle a broad variety of applications covering all the standard implementations necessary for controlling line-voltage HVAC systems. In addition to controlling heating, cooling and fan activity, depending on the model the can handle wireless networking and switches, passive infrared (PIR) occupancy detection using either onboard or remote sensors, and dehumidification control. The applications described here cover all these features, and in combination with the s advanced scheduling and occupancy controls can provide the functionality for any required line-voltage HVAC implementation.
3 Fan Coil Controller 3 AND SCS FAN COIL TERMINAL EQUIPMENT CONTROLLERS Commercial interface (local override) Power Part Number Description Humidity PIR Cover Communication A0Axx Stand-alone fan coil terminal equipment controller No No Stand-alone A0Bxx BACnet fan coil terminal equipment controller No No BACnet A0Pxx Wireless fan coil terminal equipment controller No No ZigBee Pro Wireless A5Axx Stand-alone fan coil terminal equipment controller No Yes Stand-alone A5Bxx BACnet fan coil terminal equipment controller No Yes BACnet A5Pxx Wireless fan coil terminal equipment controller Yes Yes ZigBee Pro Wireless VTR8350A0Axx Stand-alone fan coil terminal equipment controller Yes No Stand-alone VTR8350A0Bxx BACnet fan coil terminal equipment controller Yes No BACnet VTR8350A0Pxx Wireless fan coil terminal equipment controller Yes No ZigBee Pro Wireless VTR8350A5Axx Stand-alone fan coil terminal equipment controller Yes Yes Stand-alone VTR8350A5Bxx BACnet fan coil terminal equipment controller Yes Yes BACnet VTR8350A5Pxx Wireless fan coil terminal equipment controller Yes Yes ZigBee Pro Wireless Transformer relay packs for fan coil units Power Part Number Description SC3500E5045 Transformer relay pack five relay fan outputs SC3504E5045 Transformer relay pack five relay fan outputs, and four outputs SC3514E5045 Transformer relay pack five relay outputs, smart VDC OCC output, and four inputs SC3400E5045 Transformer relay pack four relay outputs and smart VDC output SC3404E5045 Transformer relay pack four relay outputs, smart VDC output, and four inputs SC3300E5045 Transformer relay pack three slave fan outputs Wireless accessories for Series Power Part Number Description SED-DOR-P-5045 Wireless door switch SED-WIN-P-5045 Wireless window switch
4 4 Fan Coil Controller VTR83X0AXPXX WITH SC3500E5000 RELAY: HEATING/COOLING 4-PIPE FAN COIL UNIT WITH 3-SPEED FAN AND 2-POSITION VALVES WITH WIRELESS DOOR SWITCH Fan Airflow Direction Cooling Coil Heating Coil 2 POSITION COOLING VALVE 2 POSITION HEATING VALVE Onboard PIR Sensor SC3500E5000 AND / OR Door Switch SED-DOR-P-5000 Remote PIR Sensor Refer to the Wireless Door and Window Switch Installation Guide for the door pairing procedure. Configuration Parameter Name Configuration Settings Fan Menu L-M-H-A Fan cont. heat. On BI2 Door Dry Pulsed heating Off Pipe no. 4 Seq. operation Ht - Cl
5 Fan Coil Controller 5 SC3500E Tx/Rx 2 7 Vdc 3 Com BACnet+ BACnet- BACnet REF Tx / Rx 7 VDC Com UI 16 - BI1 UI 17 - BI2 SCom Sequence of Operation and Wiring Options Occupied Mode Setpoints revert to those defined by occupied cooling and heating. Stand-by Mode (only available when PIR motion detector sensor is used) Setpoints revert to those defined by stand-by cooling and heating. Unoccupied Mode Setpoints revert to those defined by unoccupied heating and cooling. Occupied Override Mode System reverts to occupied mode for duration determined by ToccTime parameter. On Call for Cool Cooling valve opens to maintain room temperature. Heating valve closed. On Call for Heat Heating valve opens to maintain room temperature. Cooling valve closed. Wireless Door Switch Wireless door switch automatically toggles occupancy. BACnet and Wireless communication models available (see Appendix B for network wiring). Can be configured for 2-pipe systems (without changeover). Binary inputs can be configured to control occupancy via door or window contact, remote motion sensor, or remote night setback.
6 6 Fan Coil Controller VTR8350AXXXX WITH SC3404E5000 RELAY: COOLING AND ELECTRIC HEAT 2-PIPE FAN COIL UNIT WITH 3-SPEED FAN, DEHUMIDIFICATION AND 2-POSITION VALVES Fan Airflow Direction Cooling Coil Electric Heating 2 POSITION COOLING VALVE SSR SOLID STATE RELAY (GENERIC) SC3404E5000 Configuration parameter name Configuration settings Fan menu L-M-H-A Fan cont. heat On Pulsed heating On Pipe no. 2 Seq. operation Ht-Cl
7 Fan Coil Controller 7 SC3404E Tx/Rx 2 7 Vdc Tx / Rx 7 VDC Com 3 4 Com RUI 1 5 SCom 6 RBI 2 7 SS 8 RS 9 Heat - 10 Heat + BACnet+ BACnet- BACnet REF UI 16 - BI1 UI 17 - BI2 SCom SOLIDSTATE RELAY (4-32Vdc) (-) (+) Sequence of Operation and Wiring Occupied Mode Setpoints revert to those defined by occupied cooling and heating. Stand-by Mode (only available when PIR motion detector sensor is used) Setpoints revert to those defined by stand-by cooling and heating. Unoccupied Mode Setpoints revert to those defined by unoccupied heating and cooling. Occupied Override Mode System reverts to occupied mode for duration determined by ToccTime parameter. On Call for Cool Cooling valve opens to maintain room temperature. On Call for Heat Electric heat operates to maintain room temperature. Cooling valve closes and dehumidification is disabled. On a Demand for Dehumidification Dehumidification achieved via cooling coil using reheat if necessary. Dehumidification only allowed in COOL mode or if cooling is enabled in AUTO mode. Dehumidification disabled if room temperature falls below low ambient lockout temperature, which is cooling setpoint minus configuration defined deadband value. Options BACnet and Wireless communication models available (see Appendix B for network wiring). Remote wall mount or return duct sensor ready. Can be configured for 2-pipe systems with changeover. Binary inputs can be configured to control occupancy via door or window contact, remote night setback, or provide alarms for service or filter monitoring. Universal input can be configured for changeover sensor.
8 8 Fan Coil Controller AXPXX WITH SC3504E5000 RELAY: HEATING/COOLING WITH CHANGEOVER SENSOR 2-PIPE FAN COIL UNIT WITH 3-SPEED FAN AND WIRELESS WINDOW SWITCH Window Switch SED-WIN-P-5000 Fan Airflow Direction Cooling / Heating Coil Supply Sensor 2 POSITION COOLING VALVE / HEATING VALVE SENSOR AND / OR C/O SENSOR Changeover Sensor: 10K Ohm type 2 Onboard PIR Sensor SC3504E5000 Supply Sensor: 10K Ohm type 2 Configuration Parameter Name Configuration Settings Fan Menu L-M-H-A Fan cont On BI1 Window RUI1 COS Pipe No 2 Seq. operation Cool
9 Fan Coil Controller 9 SC3504E Tx/Rx 2 7 Vdc Tx / Rx 7 VDC 3 Com 4 RUI 1 5 SCom 6 RBI 2 7 SS 8 RS BACnet+ Com BACnet- BACnet REF UI 16 - BI1 UI 17 - BI2 SCom Sequence of Operation and Wiring Occupied Mode Setpoints revert to those defined by occupied cooling and heating. Stand-by Mode (only available when PIR motion detector sensor is used) Setpoints revert to those defined by stand-by cooling and heating. Supply Air Sensor Only used for monitoring. Shows automatically if sensor is connected. Wireless Window Switch Wireless window switch automatically locks out heating/cooling when window is opened. Unoccupied Mode Setpoints revert to those defined by unoccupied heating and cooling. Occupied Override Mode System reverts to occupied mode for duration determined by ToccTime parameter. On Call for Cool If supply water temperature is less than 24 C (75F), valve opens to maintain room temperature, else the valve closes. On Call for Heat If supply water temperature is greater than 25 C (77F), valve opens to maintain room temperature. Options BACnet and Wireless communication models available (see Appendix B for network wiring). Remote wall mount or duct sensor ready. Binary inputs can be configured to control occupancy via door or window contact, remote motion sensor, remote night setback, or provide alarms for service or filter monitoring.
10 10 Fan Coil Controller VTR8350AXXXX WITH SC3400E5000 RELAY: COOLING AND ELECTRIC HEAT 2-PIPE FAN COIL UNIT WITH 3-SPEED FAN, DEHUMIDIFICATION AND 2-POSITION VALVES Fan Airflow Direction Cooling Coil Electric Heating 2 POSITION COOLING VALVE SSR SOLID STATE RELAY (GENERIC) SC3400E5000 Configuration parameter name Configuration settings Fan menu L-M-H-A Fan cont. heat. On Pulsed Heating On Pipe No 2 Seq. operation Cool-Rht
11 Fan Coil Controller 11 SC3400E Tx / Rx 7 VDC Com BACnet+ BACnet- BACnet REF UI 16 - BI1 UI 17 - BI2 SCom SOLIDSTATE RELAY (4-32Vdc) (-) (+) Sequence of Operation and Wiring Occupied Mode Setpoints revert to those defined by occupied cooling and heating. Stand-by Mode (only available when PIR motion detector sensor is used) Setpoints revert to those defined by stand-by cooling and heating. Unoccupied Mode Setpoints revert to those defined by unoccupied heating and cooling. Occupied Override Mode System reverts to occupied mode for duration determined by ToccTime parameter. On Call for Cool Cooling valve opens to maintain room temperature. On Call for Heat Electric heat operates to maintain room temperature. Cooling valve closed and dehumidification is disabled. On a Demand for Dehumidification Dehumidification achieved via cooling coil using reheat if necessary. Dehumidification only allowed in COOL mode or if cooling is enabled in AUTO mode. Dehumidification disabled if room temperature falls below low ambient lockout temperature, which is cooling setpoint minus configuration defined deadband value. Options BACnet and Wireless communication models available (see Appendix B for network wiring). Binary inputs can be configured to control occupancy via door or window contact, remote motion sensor, remote night setback, or provide alarms for service or filter monitoring.
12 12 Fan Coil Controller AXXXX WITH SC3514E5000 RELAY: HEATING/COOLING 2-PIPE FAN COIL UNIT WITH 3-SPEED FAN, FRESH AIR DAMPER AND 2-POSITION VALVES Fresh Air Fan Airflow Direction Cooling / Heating Coil Supply Sensor DAMPER 2 POSITION COOLING VALVE / HEATING VALVE SENSOR Return Air SC3514E5000 C/O SENSOR Supply Sensor: 10K Ohm type 2. Changeover Sensor: 10K Ohm type 2. Configuration Parameter Name Configuration Settings Fan menu L-M-H-A Fan cont. heat On BI1 Window RUI1 COS Pulsed Heating Occ Out Pipe no. 2 Seq. operation Cool
13 Fan Coil Controller 13 SC3514E Tx/Rx 2 7 Vdc Tx / Rx 7 VDC 3 Com 4 RUI 1 5 SCom 6 RBI 2 7 SS 8 RS 9 OCC - 7Vdc RELAY COIL BACnet+ BACnet- BACnet REF UI 16 - BI1 UI 17 - BI2 Com SCom Sequence of Operation and Wiring Occupied Mode Setpoints revert to those defined by occupied cooling and heating. The occupancy output opens fresh air damper to minimum position. Stand-by Mode (only available when PIR motion detector sensor is used) Setpoints revert to those defined by stand-by cooling and heating. Unoccupied Mode Setpoints revert to those defined by unoccupied heating and cooling. The fresh air damper closes. Occupied Override Mode System reverts to occupied mode for duration determined by ToccTime parameter. On Call for Cool If supply water temperature is less than 24 C (75F), valve opens to maintain room temperature, else the valve closes. On Call for Heat If supply water temperature is greater than 25 C (77F), valve opens to maintain room temperature, else the valve closes. Supply Air Sensor Only used for monitoring. Shows automatically if sensor is connected. Options BACnet and Wireless communication models available (see Appendix B for network wiring). Remote wall mount or return duct sensor ready. Binary inputs can be configured to control occupancy via door or window contact, remote motion sensor, remote night setback, or provide alarms for service or filter monitoring.
14 14 Fan Coil Controller AXXXX WITH SC3500E5000 AND SC3300E5000 RELAYS: HEATING/COOLING 4-PIPE FAN COIL UNIT WITH 3-SPEED FAN AND 2-POSITION VALVES WITH SLAVE RELAY PACK Fan Airflow Direction Cooling Coil Heating Coil 2 POSITION COOLING VALVE 2 POSITION HEATING VALVE SC3300E5000 SC3500E5000 Configuration Parameter Name Configuration Settings Fan menu L-M-H-A Fan cont. heat On Pipe No 4 Seq. operation Ht-Cl
15 Fan Coil Controller 15 SC3500E5000T 1 2 Tx / Rx 7 VDC Com 3 SC3300E BACnet+ BACnet- BACnet REF UI 16 - BI1 UI 17 - BI2 SCom Sequence of Operation and Wiring Options Occupied Mode Setpoints revert to those defined by occupied cooling and heating. Stand-by Mode (only available when PIR motion detector sensor is used) Setpoints revert to those defined by stand-by cooling and heating. Unoccupied Mode Setpoints revert to those defined by unoccupied heating and cooling. Occupied Override Mode System reverts to occupied mode for duration determined by ToccTime parameter. On Call for Cool Cooling valve opens to maintain room temperature. Heating valve closes. On Call for Heat Heating valve opens to maintain room temperature. Cooling valve closes. BACnet and Wireless communication models available (see Appendix B for network wiring). Can be configured for 2-pipe systems without changeover. Binary inputs can be configured to control occupancy via door or window contact, remote motion sensor, remote night setback, or provide alarms for service or filter monitoring.
16 16 Fan Coil Controller AXPXX WITH SC3504E5000 RELAY: COOLING AND ELECTRIC HEAT 2-PIPE FAN COIL UNIT WITH 3-SPEED FAN AND 2-POSITION VALVES WITH WIRED WINDOW SWITCH Window Switch SED-WIN-P-5000 Fan Airflow Direction Cooling / Heating Coil Supply Sensor 2 POSITION COOLING VALVE / HEATING VALVE SENSOR AND / OR C/O SENSOR Changeover Sensor: 10K Ohm type 2 Onboard PIR Sensor SC3504E5000 Supply Sensor: 10K Ohm type 2 Configuration Parameter Name Fan menu L-M-H-A Fan cont. heat On BI1 Window RUI1 COS Pipe no. 2 Seq. operation Cool Configuration Settings
17 Fan Coil Controller 17 SC3504E Tx/Rx 2 7 Vdc 3 Com 4 RUI 1 5 SCom 6 RBI 2 7 SS 8 RS BACnet+ BACnet- BACnet REF UI 16 - BI1 UI 17 - BI2 Tx / Rx 7 VDC Com SCom BI1 (Window) SCom Sequence of Operation and Wiring Occupied Mode Setpoints revert to those defined by occupied cooling and heating. Stand-by Mode (only available when PIR motion detector sensor is used) Setpoints revert to those defined by stand-by cooling and heating. Unoccupied Mode Setpoints revert to those defined by unoccupied heating and cooling. Occupied Override Mode System reverts to occupied mode for duration determined by ToccTime parameter. On Call for Cool If supply water temperature is less than 24 C (75F), valve opens to maintain room temperature, else the valve closes. On Call for Heat If supply water temperature is greater than 25 C (77F), valve opens to maintain room temperature, else the valve closes. Supply Air Sensor Only used for monitoring. Shows automatically if sensor is connected. Wired Window Switch The window switch automatically locks out heating/cooling when window opens. Options BACnet and Wireless communication models available (see Appendix B for network wiring). Models available with factory installed PIR sensor. Remote wall mount or duct sensor ready. Can be configured for 2-pipe systems with changeover. Binary inputs can be configured to control occupancy via door or window contact, remote night setback, or provide alarms for service or filter monitoring. Universal input can be configured for changeover sensor.
18 18 Fan Coil Controller AXPXX WITH SC3500E5000 RELAY: HEATING/COOLING 4-PIPE FAN COIL UNIT WITH 3-SPEED FAN AND 2-POSITION VALVES WITH WIRED DOOR SWITCH Fan Airflow Direction Cooling Coil Heating Coil 2 POSITION COOLING VALVE 2 POSITION HEATING VALVE Onboard PIR Sensor SC3500E5000 AND / OR Door Switch SED-DOR-P-5000 Remote PIR Sensor Configuration Parameter Name Configuration Settings Fan menu L-M-H-A Fan cont. heat On BI2 Door Dry Pipe No 4 Seq. Operat Ht-Cl
19 Fan Coil Controller 19 SC3500E Tx/Rx 2 7 Vdc 3 Com BACnet+ BACnet- Tx / Rx 7 VDC Com BACnet REF UI 16 - BI1 UI 17 - BI2 SCom BI2 (Door) SCom Sequence of Operation and Wiring Options Occupied Mode Setpoints revert to those defined by occupied cooling and heating. Stand-by Mode (only available when PIR motion detector sensor is used) Setpoints revert to those defined by stand-by cooling and heating. Unoccupied Mode Setpoints revert to those defined by unoccupied heating and cooling. Occupied Override Mode System reverts to occupied mode for duration determined by ToccTime parameter. On Call for Cool Cooling valve opens to maintain room temperature. Heating valve closes. On Call for Heat Heating valve opens to maintain room temperature. Cooling valve closes. Door Switch Door switch automatically toggles occupancy. BACnet and Wireless communication models available (see Appendix B for network wiring). Models available with factory installed PIR sensor. Can be configured for 2-pipe systems without changeover. Binary inputs can be configured to control occupancy via door or window contact, remote motion sensor, remote night setback, or provide alarms for service or filter monitoring.
20 20 Fan Coil Controller APPENDIX A - PASSIVE INFRA-RED (PIR) MOTION DETECTOR COVER SPECIFICATIONS PIR cover sequence of operation Initially, the controller is in Stand-by mode. Stand-by setpoints are used at the controller. As soon as the PIR detects motion, the Occupancy status switches to Occupied and the Stand-By Time timer is reset. The Occupied setpoints are used. If no motion is detected in the room for the entire Stand-By Time duration (adjustable parameter), the room then switches to Stand-by mode and stand-by setpoints are used. While in Stand-by mode, if no motion is detected for the entire Unoccupied Time period (adjustable parameter), the room switches to Unoccupied mode and uses its Unoccupied setpoints. While in Stand-By or Unoccupied mode, any motion will switch the room back to Occupied mode. Typical Detection Pattern for PIR Lens Horizontal Angles (Typical) Recommended installation height for PIR sensor: 4-5 ft. / m Transverse motion: 4-5 ft/s / 1.5 m/s Vertical Angle (Typical) Sensor Ranges A = 20 ft. / 6.1 m B = 14 ft. / 4.3 m C = 11 ft. / 3.4 m 40 O A Center 30 O 20 O B B 20 O 20 O C C 20 O Center Energy savings The PIR can maximize your energy saving from 10-30% by relaxing temperature set points in unoccupied zones during scheduled periods. Energy Usage (KWh) Typical Savings of 10-30% 85 50% % % % % % Time of Day (EST) Typical Consumption PIR Thermostat Consumption Savings Saving Percentage
21 Fan Coil Controller 21 APPENDIX B - OPTION NETWORK WIRING IF COMMUNICATING MODELS ARE USED BACnet communication wiring Wireless Communication BACnet thermostat 1 BACnet thermostat 2 BACnet thermostat ref + - ref + - ref Notes: - Wiring should be daisy chained - Respect polarity - If using 2 conductors shielded wires, connect the shield of each feed together on the back of the controller. ONLY ground the shield at one location. DO NOT connect the shield to the ref terminal. No communication wires required APPENDIX C - CONTROLLERS OCCUPANCY SEQUENCE OF OPERATION SCHEMATIC Setpoints Unoccupied cool 26.5 C 80 F Stand-by cool Occupied cool Occupied heat Stand-by heat Unoccupied heat Movement detected - Stand-by timer reset 22 C 72 F Deadband Stand-by time Into Stand-by mode - Unoccupied timer reset 24.5 C 76 F Deadband 70 F 70 F 21 C 21 C Unoccupied time Into Unoccupied mode 62 F 16.5 C Next movement detected 66 F 19 C Deadband 22 C 72 F Time
22 22 Fan Coil Controller APPENDIX D - SED SERIES - WIRELESS DOOR & WINDOW SWITCH Wireless ZigBee Pro door & window switch Wireless door switches used with an onbaord or remote PIR sensor provide advanced local occupancy routines allowing for increased energy savings during occupied hours without sacrificing occupant comfort. Wireless window switches are used to monitor exterior windows and or patio and balcony doors being opened or closed. This prevents unnecessary energy consumption by the tenants. Fan Coil Terminal Equipment Controllers with SED Series ZigBee wireless switches can be used in network ready mode with or without integration to a central management system to allow for advanced functions such as central reservation and occupancy functions. A combination of up to twenty SED Series door and or window switches can be used simultaneously with a single Fan Coil Terminal Equipment Controller. The SED Series switches are factory delivered with 2 AAA batteries and are ready to be installed, configured and used right out of the box. Due to the extremely small current consumption of the switches, the expected battery life is approximately 10 years and is equivalent to the battery shelf life. No tools are required for commissioning or servicing the door switch. A very simple interface with an onboard LED & hidden switch provides all the required functions for local interaction. Local information for battery life and connectivity (heartbeat) are provided at the Fan Coil Terminal Equipment Controller local display through the ZigBee wireless network. Each switch is factory supplied with a magnet, a locking security tamper proof screw and self tapping mounting screws. Model selection Window Switch Door Switch SED-WIN-P-5045 SED-DOR-P-5045 LED (switch side) Pull Tab Hidden Switch
23 Fan Coil Controller 23 APPENDIX E - CONTROLLER & SC3000 RELAY PACK Product overview The Fan Coil Controller offers a new cost-effective solution for upgrading line-voltage fan coil unit thermostats. The terminal Equipment Fan Coil Unit Controllers are available as BACnet MSTP or wireless ZigBee Pro networked models. No previous building automation training is required for the easy installation and commissioning process. Installation can be completed in approximately fifteen minutes, reducing costs and providing increased savings. The SC3000 Series Line Voltage Switching Transformer Relay Pack Controllers has been designed for silent control of typical high voltage fan coil device loads (90 to 277 VAC multi-voltages capable). It uses advanced microprocessor-based circuitry with a built-in transformer that eliminates all typical required peripheral components when automating a Fan Coil unit with traditional building automation systems. The SC3000 Series Line Voltage Switching Transformer Relay Pack(s) operate as slave unit(s) under the control of a single master Terminal Equipment Controller. A single Terminal Equipment Controller can control up to 10x SC3000 Series Relay Pack. The SC3000 Series Relay Packs are line-powered units. The extremely compact unit locally contains all the relay outputs for fan switching and valve control. Models are also available for extra monitoring / control inputs of the Fan Coil Units. Typical fan coil unit setup Typical Fan Coil Unit H C C C 1 Tx/Rx 2 7 Vdc Power Supply 3 Com SC3404E RUI 1 5 SCom 6 RBI 2 Electrical Cabinet WHITE Vac - 50/60 Hz 1/2HP + 5A Max Comb. or 13A+ 5A Max Comb Amb. Temp. 50oC 7 SS 8 RS BLACK 9 Heat 10 Heat + FAN LOW 1/2 HP or 13A FAN MED Max 5A Max RED BLUE FAN HIGH BROWN COOL YELLOW 1 Tx/Rx 2 7 Vdc 3 Com Power Supply 4 RUI 1 5 SCom xxx-xxxx-xx 6 RBI 2 WHITE Vac - 50/60 Hz 1/2HP + 5A Max Comb. or 13A+ 5A Max Comb Amb. Temp. 50oC 7 SS 8 RS 9 Heat 10 Heat + BLACK FAN LOW 1/2 HP or 13A FAN MED Max 5A Max RED BLUE FAN HIGH BROWN COOL YELLOW Mixed daisy chained and Star topology Daisy chained topology Star topology Viconics Technologies Inc Langelier Blvd. St.-Leonard Quebec Canada sales@viconics.com H1P 3K9 Tel: (514) Low Voltage Connections to Controller Fax: (514) November 2014
Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide
Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers TABLE OF CONTENTS Overview 2 VT8600 Rooftop Unit Heat Pump and Indoor Air Quality Controllers 3 VT86X0U5X00B
More informationRooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers
Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers TABLE OF CONTENTS Overview 2 VT86X0U5X00B 2 heating / 2 Cooling for Rooftop unit and Indoor air quality 3
More informationRooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers
Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide SE8600 Series Room Controllers 2 TABLE OF CONTENTS Overview 2 SE8600 Rooftop Unit and Indoor Air Quality Controllers 3 SE8600UxBxx 2 Heating
More informationVT8300 Series Installation Guide 24 Vac Low Voltage
Vac Low Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation Configurable BI/UI Universal Inputs Overview Setup Screen Display Terminal Identification & Function Terminal
More informationTEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs
TEC2620 Series Non-Programmable Fan Coil Network Thermostat ler and Remote I/O Relay Packs TEC2620H-0, TEC2620C-0, TEC2620H-0+PIR, TEC2620C-0+PIR, TEC2621H-0, TEC2621C-0, TEC2621H-0+PIR, TEC2621C-0+PIR
More information0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom
Viconics VT7350 Series PIR Ready Fan-coil Controllers General The VT7350 series are PIR Ready low-voltage microprocessor-based fan-coil controllers. Models are available controlling single speed and multi-speed
More informationDocument # R01
Viconics VT7600 Series PIR-Ready Rooftop Unit Controllers Part 1 General The VT7600 series is designed for single-stage and multi-stage control of heating/cooling equipment such as rooftop and self-contained
More informationCONTENTS. Installation Guide. VT7200 Series
VT7200 Series Installation Guide For mercial HVAC Applications November 2015 CONTENTS Installation 2 Location 2 Installation 2 Configurable BI/UI inputs overview 4 Network ready 6 Terminal, Identification
More informationT60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability
T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability Product Bulletin T601DFH-4, T602DFH-4, T603DFH-4, T604DFH-4, T605DFH-4, T601DFH-4+PIR, T602DFH-4+PIR,
More informationSER7300 Series Installation Guide for HVAC FCU Applications
SER7300 Series Installation Guide for HVAC FCU Applications CONTENTS Installation 2 Location 2 Installation 2 Terminal, Identification and Function 3 Communication wiring to SC3xxxX Relay Pack 3 Network
More informationVT8600 Series Installation Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller
Installation Guide Rooftop Unit, Heat Pump and Indoor Air Quality ontroller ONTENTS Installation 2 onfigurable BI/UI Universal Inputs Overview 3 Setup Screen Display 3 Terminal Identification & Function
More informationPIR Application Guide for the for VT76xxX5x00(X) Series thermostats (Issue Date: November, 2015)
PIR Application Guide for the for VT76xxX5x00(X) Series thermostats (Issue Date: November, 2015) 1 Product Overview The VI-PIR Accessory covers with embedded Passive Infra-Red motion detector have been
More informationDocument # R00
Viconics VT7200 Series PIR Ready Zoning Thermostats General The VT7200 series PIR Ready low-voltage microprocessor-based zoning thermostats have been specifically designed to control either 0-10Vdc, staged,
More informationExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling
ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling DataSheet ev 1.12.304/4.0 June 14, 2016 Operating Sequence
More informationTB7300 Series Communicating Fan Coil Thermostats 24 VAC/FOR COMMERCIAL AND LODGING HVAC APPLICATIONS
TB7300 Series Communicating Fan Coil Thermostats /FOR MERCIAL AND LODGING HVAC APPLICATIONS APPLICATION INSTALLATION INSTRUCTIONS The TB7300 PI thermostat family is specifically designed for fan coil control.
More informationTB7200 Series Communicating Zone Thermostats
TB7200 Series Communicating Zone Thermostats TB7200 Series Thermostat INSTALLATION INSTRUCTIONS APPLICATION The TB7200 Series PI thermostat family is specifically designed for zoning applications. The
More informationT62xx-0 Fan Coil Retrofit Thermostat Controller and R-xxxxx-0 Fan Coil Retrofit Relay Packs
T62xx-0 Fan Coil Retrofit Thermostat Controller and R-xxxxx-0 Fan Coil Retrofit Relay Packs T620H-0, T620C-0, T621H-0, T621C-0, R-HCC40-0, R-HCC44-0,R-MPR20-0, R-MPR24-0, R-SFC40-0 Part No. 24-9890-1419,
More informationSE7200 Series Installation Guide
SE7200 Series Installation Guide Install Guide for Low Voltage Zoning Room Controller For mercial HVAC Applications CONTENTS Installation 2 Preparation 2 Location 2 Installation 2 Terminal, Identification
More informationModels available. Features and benefits. Models available with internal humidity sensing Advanced occupancy functions
PIR Ready VT7300 Series Low Voltage Fan Coil Thermostats For mercial and Lodging HVAC Applications September 1, 2010 Product overview The VT7300 PI thermostat family is specifically designed for fan coil
More informationT606MSx-4 and T606MSx-4+PIR Series Multi-Stage
T606MSx-4 and T606MSx-4+PIR Series Multi-Stage Temperature and Humidity Controllers Product Bulletin T606MSN-4, T606MSN-4+PIR, T606MSP-4, T606MSP-4+PIR The T606MSN-4 and T606MSN-4+PIR Series Non-programmable
More informationVT8000 Series Replacement Procedure to Replace VT8000 Series Room Controller and Pair with ZigBee Pro Sensors
VT8000 Series Replacement Procedure to Replace VT8000 Series Room Controller and Pair with ZigBee Pro Sensors Overview 2 This procedure shows how to replace VT8000 Room Controllers already installed, as
More informationTEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page
Code. LIT-1900896 Issued February 17, 2017 TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page Description The TEC3000 Series Thermostat
More informationExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C
ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C DataSheet ev 1.10.403/4.02 November 6, 2012 Operating Sequence Standard Occupied During
More informationT600MEP-2 Programmable Economizer Thermostat
Installation Instructions Issue Date January 19, 2005 T600MEP-2 Programmable Economizer Thermostat Application The T600MEP-2 is a programmable thermostat for control of single- or two-stage unitary rooftop
More informationLG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls
LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls 1 Article I. General Section 1.01 Section 1.02 Section 1.03 System Description Quality Assurance Storage and Handling Article
More informationPIR Ready VT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications September 1, 2010
Product overview PIR Ready VT7200 Series Low Voltage Zoning Thermostats For mercial HVAC Applications September 1, 2010 The VT7200 PIR Ready thermostat family is specifically designed for zoning applications.
More informationCommercial Touchscreen Thermostat
55,13M 1/27 Supersedes 12/25 Commercial Touchscreen Thermostat 25 Lennox Industries, Inc. Dallas, Texas, USA APPLICATION Page 1 INSTALLATION INSTRUCTIONS The Lennox Commercial Touchscreen Thermostat provides
More informationProduct Manual SZ1009
Product Manual SZ1009 Conventional Heating & Cooling Thermostats with Heat Pump Mode Communicating Thermostats Description The SZ1009 is a microprocessor-based mable thermostats designed for conventional
More informationExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet
ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet DataSheet ev 1.2.008/4.1 July 30, 2013 Operating Sequence Standard Occupied During normal occupied operation the display will show
More informationNCU Mounting Details
Revision Date December 4, 2013 RS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units Installation and Operation Instructions Dimensions in mm Power Control Unit Display Control Unit
More informationTEC Networked Multi-Stage Economizer Thermostat
Installation Instructions Issue Date January 19, 2005 TEC2104-2 Networked Multi-Stage Economizer Thermostat Application The TEC2104-2 thermostat is an N2 networked thermostat that provides control of single-
More informationDigital Precise Air Control - DPAC
Digital Precise Air Control - DPAC Mode Enable Sensor Options The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during Occupied operation. The following options
More informationProduct Manual SZ1022/SZ1031/SZ1035/
Product Manual SZ1022/SZ1031/SZ1035/ Conventional Heating & Cooling Thermostats Communicating Thermostats Description The SZ1022, SZ1031, and SZ1035, are microprocessorbased mable thermostats designed
More informationInstallation Instructions. Applications. North American Emissions Compliance. Installation. Part No , Rev. Issued February 8, 2010
TEC22x6(H)-4 and TEC22x6H-4+PIR Series LONWORKS Network Thermostat Controllers with Dehumidification Capability, Fan Control, and Occupancy Sensing Capability Installation Instructions Part No. 24-9890-1249,
More informationZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment
ZonexCommander ZonexCommander(Plus) Network All Your HVAC Equipment Centralized DDC Communications for Stand-Alone HVAC and Zoned Systems Installation and Applications Manual Part #ZCMAN Rev. Oct 2014
More informationT60xDFH-3 and T60xDFH-3+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability
T60xDFH-3 and T60xDFH-3+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability Installation Instructions Part No. 24-9890-692, Rev. B Issued August 31, 2009 Supersedes
More informationI/O ZONE 560/583 USERS GUIDE
I/O ZONE 560/583 USERS GUIDE 641-224 641-242 641-237 1 Table of Contents Hot Gas Re-Heat Valve On/Off:... 15 THE ZONE CONTROLLER...4 Modulating Re-Heat Valve:... 16 SPECIFICATIONS...5 CONTROLLER COMPONENTS...6
More informationProduct Catalog. Small Building Systems.
Product Catalog Small Building Systems www.viconics.com Table of Contents VBZS - Viconics BACnet Zoning System VZ1 VZ7200F5000B Bacnet Zone Thermostat... VZ5 VZ7656B1000B Bacnet Rooftop Unit Thermostat...
More informationNetworkable Fan Coil Controller Specification and Installation Instructions
Controller Models EFCB10T-OE1 (24Vac / 0 relays) EFCB12T-OE1 (240Vac / 0 relays) EFCB10TU4-OE1 (24Vac / 4 relays) EFCB12TU2-OE1 (240Vac / 2 relays) EFCB12TU4-OE1 (240Vac / 4 relays) TFL Series Thermostat
More informationTEC BACnet MS/TP Networked Thermostat Controller with Single Proportional Output and One-Speed Fan Control
TEC2645-4 BACnet MS/TP Networked Thermostat Controller with Single Proportional Output and One-Speed Fan Control Installation Instructions Part No. 24-9890-1028, Rev. B Issued June 22, 2010 Supersedes
More informationETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings
ETNC-FC-BAC-PIR- Rev. Index Operating instructions....- Turning the thermostat and OFF Selecting temperature scale Adjusting the Set point temperature (for set point and set points configurations) Selecting
More informationVT7600 Series Programmable & Non-Programmable Thermostats With Humidification & Dehumidification Strategy For Commercial HVAC Applications
VT7600 Series Programmable & Non-Programmable Thermostats With Humidification & Dehumidification Strategy For Commercial HVAC Applications (Issue Date June 12, 2008 028-0171 R5 Product overview The VT76x7
More informationTEC2664Z-2 BACnet MS/TP Rooftop Controller for Stand-Alone and Networked Zoning Systems Part No , Rev. C
TEC2664Z-2 BACnet MS/TP Rooftop Controller for Stand-Alone and Networked Zoning Systems Part No. 24-9890-684, Rev. C Issued March 9, 2009 Supersedes October 6, 2008 Applications The TEC2664Z-2 Rooftop
More informationZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment
ZonexCommander ZonexCommander(Plus) Network All Your HVAC Equipment Centralized DDC Communications for Stand-Alone HVAC and Zoned Systems Installation and Applications Manual Part #ZCMAN Rev. July 2010
More informationTEC and TEC PIR BACnet MS/TP Networked Multi-Stage Thermostat Controllers
TEC2603-4 and TEC2603-4+PIR BACnet MS/TP Networked Multi-Stage Thermostat Controllers TEC2603-4 and TEC2603-4+PIR Applications The TEC2603-4 and TEC2603-4+PIR Thermostat Controllers are BACnet Master-Slave/
More informationSECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS
PART 1 - GENERAL SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and other equipment. B. See Division 23 Section
More informationVH7200 Humidistat Series For Humidification & Dehumidification Control For Commercial HVAC Applications (Issue Date January 22, R7)
VH7200 Humidistat Series For Humidification & Dehumidification Control For Commercial HVAC Applications (Issue Date January 22, 2013 028-0208 R7) 1 Product overview The VH7200 humidity controller family
More informationTEC and TEC PIR BACnet MS/TP Network Multi-Stage Temperature and Humidity Controllers
TEC2613-4 and TEC2613-4+PIR BACnet MS/TP Network Multi-Stage Temperature and Humidity Controllers Installation Instructions TEC2613-4 and TEC2613-4+PIR Applications The TEC2613-4 and TEC2613-4+PIR Temperature
More informationAirTrak. Digital Control System. User Manual. Touchscreen Systems
AirTrak Digital Control System User Manual Touchscreen Systems Rev. 10-29-15 1 2 Table of Contents OVERVIEW... 8 NETWORKING... 9 AIRTRAK DEFAULT SETTINGS... 9 Unit Operating Modes... 10 MRT Controls...
More informationTEC210x-2 Series Networked Thermostats
Product Bulletin Issue Date February 1, 2005 TEC210x-2 Series Networked Thermostats The TEC210x-2 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment
More informationNatural Ventilation Controller with 24vDC drive NVC-1204
Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-038 08/16 FEATURES SPECIFICATION > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) >
More informationModels Available. Features and benefits. Through the network or smart local occupancy sensing. Advanced occupancy functions
PIR Ready VT76X7 Series Programmable & Non-Programmable Thermostats With Humidification & Dehumidification Strategy For Commercial HVAC Applications September 1, 2010 Product overview The VT76x7 PI thermostat
More informationDual Technology Wall Mounted Occupancy Sensor. Manual & Specification
Dual Technology Wall Mounted Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 December 16, 2013 1. INTRODUCTION
More informationInstallation, Operation, and Troubleshooting Instructions
Installation, Operation, and Troubleshooting Instructions 48/50HJ004-024 48/50TJ004-028 Apollo Control GENERAL The Apollo control is a relay pack which is factory wired and mounted in the Carrier rooftop
More informationNatural Ventilation Controller with 24vDC drive NVC-1204
Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-036 08/11 FEATURES > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) > 3 x 0-10V outputs
More informationINSTALLATION, OPERATION & QUICK START GUIDE
INSTALLATION, OPERATION & QUICK START GUIDE Controller CS9B-THOA CS9B-THOCA Models: CS9BE-THOA CS9BE-THOCA Bard Manufacturing Company, Inc. Bryan, Ohio 4506 www.bardhvac.com Manual: 00-684 Supersedes:
More information1.0 Digital Controller
Form CP-AHU D19_D21_D22 (11-17) D303072-A Obsoletes Forms CP-Preeva-D21 (1-16) Doc No 303072, CP-Preeva-D19 (1-16) Doc No 303071 Applies to: Preeva, MAPS, MAPS II, RPB, RPBL & SSCBL Series For Air Handler
More informationInstallation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats
Installation and Advanced Programming Instructions HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats These instructions are intended for installation and first time set up of the thermostat. For day to day
More informationPioneer Gold Controller Technical Guide
Pioneer Gold Controller Technical Guide Pioneer Gold Controller Code: Version 1.03 Electric Heat Expansion Module Code: Version 1.0 Used with AAON WSHP WV Series Vertical and WH Series Horizontal This
More informationTEC2100 Series Networked Thermostats
Product Bulletin Issue Date February 11, 2004 TEC2100 Series Networked Thermostats The TEC2100 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS CONTROLLER INSTALLATION, OPERATION & QUICK START GUIDE Bard CompleteStat TM CS9B-THO CS9B-THOC Models: CS9BE-THO CS9BE-THOC Bard Manufacturing Company, Inc. Bryan, Ohio 43506
More informationSECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL
SECTION 15910 SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-23 09 93 (November 2015) ----------------------------- Preparing Activity: USACE Superseding UFGS-23 09 23 (May 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS References
More informationAppendix A Equipment Used to Monitor Hotels
Appendix A Equipment Used to Monitor Hotels This Appendix describes the data-acquisition equipment that was used in the monitoring phase of the project. Monitoring equipment was used for: Fan-coil and
More informationInstallation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN
Installation and Operation Tracer ZN521 Zone Controller CNT-SVX07C-EN Installation and Operation Tracer ZN521 Zone Controller CNT-SVX07C-EN April 2005 CNT-SVX07C-EN Tracer ZN521 Zone Controller Installation
More informationVENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS
VENSTAR FAN COIL THERMOSTAT FAN COIL THERMOSTAT T1075 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS 3 Occupied, 1 Unoccupied Override capable 3 speed fan control Auto 2-pipe changeover when used with accessory
More informationTAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products
Document 475595 Microprocessor Controller for Tempered Air Products Reference Guide for the Microprocessor Controller Please read and save these instructions. Read carefully before attempting to operate
More informationJob Name Control Systems Description Date
Job Name Control Systems Description Date Project Overview The project is a describe the building and its major HVAC systems (e.g. three-story office building, served by a rooftop unit VAV system ). In
More informationPioneer Gold Controller Technical Guide. Pioneer Gold Controller Code: Version 1.1 Used with AAON WSHP WV Series Vertical and WH Series Horizontal
Pioneer Gold Controller Technical Guide Pioneer Gold Controller Code: Version 1.1 Used with AAON WSHP WV Series Vertical and WH Series Horizontal WARNING QUALIFIED INSTALLER IMPROPER INSTALLATION, ADJUSTMENT,
More informationTEC Networked Multi-Stage Thermostat
Installation Instructions Issue Date September 2, 2003 TEC2103-1 Networked Multi-Stage Thermostat Application The TEC2103-1 is an N2 networked thermostat that provides control of multi-stage Heating, Ventilating,
More informationReference Guide for Microprocessor Controller
Document 483232 Microprocessor Controller for Energy Recovery Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before attempting
More informationReference Guide for Microprocessor Controller
Document 483586 Microprocessor Controller for Dedicated Outdoor Air System Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before
More informationCommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET
CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or
More informationVerasys System Operation Overview Technical Bulletin
Contents subject to change. Verasys System Operation Overview Technical Bulletin Code No. LIT-12012370 Issued January 2016 Refer to the QuickLIT Web site for the most up-to-date version of this document.
More informationSiemens Thermostats. RDY2000BN Thermostat
Siemens Thermostats RDY2000BN Thermostat Answers for infrastructure and cities. Introducing the RDY2000BN BACnet Commercial Thermostat Bring more buildings and zones under control Reduce energy costs BACnet
More informationDual Technology Wall Switch Occupancy Sensor. Manual & Specification
Dual Technology Wall Switch Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 November 19, 2014 1. INTRODUCTION
More informationTouch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings
Touch Screen Thermostat MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series MTS/SUPER/CO2, MTS24/SUPER/CO2 Series Owner s manual and technician settings Rev. 2.4 Index 1. Owner s Manual... 3 1.1 Quick Guide. 4 1.2
More informationBACnet Points for Single Compressor Water-to- Air Heat Pumps With Hot Gas Reheat Utilizing the FX10 Controller
BACnet Points for Single Compressor Water-to- Air Heat Pumps With Hot Gas Reheat Utilizing the FX10 Controller All volatile (Output) type points will revert to the uncommanded values after a power interruption.
More informationMulti-Zone Wireless Control Training Systems ( )
Multi-Zone Wireless Control Training Systems 593306 (3467-00) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 11/2018 Table of Contents General Description 2 Courseware 2 Topic Coverage 3 List
More informationTEC and TEC PIR N2 Networked Single-Stage Thermostat Controllers
TEC2101-4 and TEC2101-4+PIR N2 Networked Single-Stage Thermostat Controllers Installation Part No. 24-9890-1206, Rev. Issued February 8, 2010 Applications The TEC2101-4 and TEC2101-4+PIR Thermostat Controllers
More information1.0 Digital Controller
1.0 Digital Controller...1 1.1 Display Function Keys...1 1.2 Thermostat Display...2 1.3 Controller hardware input output points... 4 2.0 Sequence of Operation...5 2.1 States of Operation...5 2.2 Modes
More informationTC-9102 Applications
Application Note January 7, 2004 APPLICATION NOTE TC-9102 Applications Configuring TC-9102 Applications...3 Introduction... 3 Key Concepts... 4 TC-9102 Controller... 4 Control Modes...8 Procedure Overview...
More informationSECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS
SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section
More informationTouch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings
Touch Screen Thermostat MTSC/SUPER, MTSC24/SUPER Series MTS/SUPER, MTS24/SUPER Series Owner s manual and technician settings -2 - Index 1. Owner s Manual... 4 1.1 Quick Guide. 4 1.2 Turning the unit ON
More informationCXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.
CXM/DXM CXM/DXM Digital Heat Pump Controllers Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05 Table of Contents CXM / DXM Control Features Comparison 2 Part I - CXM Control
More informationTable of Contents. WSHP Open v3
WSHP Open v3 Integration Guide CARRIER CORPORATION 2012 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-500-01 11/29/2012 Table of Contents Introduction... 1
More informationVENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS
VENSTAR FAN COIL THERMOSTAT FAN COIL THERMOSTAT T1070 NON- PROGRAMMABLE 2 OR 4 PIPE SYSTEMS Remote sensor ready 3 speed fan control Self-prompting adjustment Auto 2-pipe changeover when used with ACC-SENFC
More informationET10 Series Stand-alone LCD Fan Coil Thermostat
ET10 Series Stand-alone LCD Fan Coil Thermostat Features Modern Appearance Stylish Rotary dial and buttons Large LCD with backlight Separate power supply unit with high performance relay outputs Retention
More informationRev 2 13-APR-10. MultiFlex RCB Rooftop Controller Installation and Operation Manual
026-1707 Rev 2 13-APR-10 MultiFlex RCB Rooftop Controller Installation and Operation Manual 3240 Town Point Drive NW Suite 100 Kennesaw, GA 30144 Phone: 770-425-2724 Fax: 770-425-9319 ALL RIGHTS RESERVED.
More informationCAUTION: ELECTRICAL HAZARD
R R Installation Guide 53DF50-HW hermostat System ypes Cool Only (single stage) Heat Pump (with electric heat) CAUION: ELECRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power
More informationTEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Fan Coil Relay Packs
24-9890- 1427, Rev. B TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Fan Coil Relay Packs Part No. 24-9890-1427, Rev. B Issued March 2016 TEC2620H-0, TEC2620C-0, TEC2621H-0,
More informationTEC Networked Single-Stage Thermostat
Installation Instructions Issue Date January 19, 2005 TEC2101-2 Networked Single-Stage Thermostat Application The TEC2101-2 thermostat is an N2 networked thermostat that provides control of single-stage
More informationTEC20x7-2 Series Wireless Thermostat Controllers with Two Outputs
TEC20x7-2 Series Wireless Thermostat Controllers with Two Outputs Installation Instructions TEC2027-2, TEC2047-2 Part No. 24-9890-773, Rev. Release 4.0 Issued March 17, 2008 Applications IMPORTANT: The
More informationTEC3000 Series Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers
TEC3000 Series Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Technical Bulletin Code No. LIT-12011956 Issued November 23, 2015 Refer to the QuickLIT website for the most up-to-date
More informationMicroTech Self-Contained Air Conditioning System
Open Protocol Data Information Packet Version 2.3 Group: Controls Date: October 1999 MicroTech Self-Contained Air Conditioning System Open Protocol Data Communications t 2002 McQuay International - C O
More informationSiemens RDY2000BN. Start Up Guide
Siemens RDY2000BN Start Up Guide Answers for infrastructure and cities. What this slide set is about This is a start up guide for the RDY2000BN BACnet Commercial Thermostat. This procedure show how to
More informationFan Coil for AppController overview and specifications
Fan Coil for AppController CARRIER CORPORATION 2018 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-508-01 3/13/2018 Verify that you have the most current version
More informationOwner s Manual. Part Number 33CS250-RC
CONTENTS Page GENERAL... 1 CONFIGURATION... 1-4 Transmitter Display... 1 Transmitter Indicator... 1 Transmitter Front Panel Buttons... 1 Set Clock... 2 Programming Thermostat Schedules... 3 OPERATION...5
More informationRDY2000 Commercial Room Thermostat
Document No. 9-95 June 4, 4 RDY Commercial Room Thermostat Figure. RDY Thermostat. Product Specifications System Compatibility Conventional Up to Heating/ Cooling stages Heat Pumps Up to 4 Heating/ Cooling
More informationT170 Thermostat. Installation and Maintenance Manual. 24 VAC/ VAC 3-Speed Fan Control (Continuous or Cycling) or Staged Fan Control
Installation and Maintenance Manual IM-846 Group: Fan Coil Part Number: IM 846 Date: July 2006 T170 Thermostat 24 VAC/120 277 VAC 3-Speed Fan Control (Continuous or Cycling) or Staged Fan Control US 2006
More information