Explosion Proof Hazardous Location Roof Top A/C Units

Size: px
Start display at page:

Download "Explosion Proof Hazardous Location Roof Top A/C Units"

Transcription

1 Explosion Proof Hazardous Location Roof Top A/C Units RT-XPC Series RT-XPC Series Roof Top Air Conditioning Systems are designed to Provide Maximum Indoor Comfort while meeting the demanding requirement of Severe Duty Industrial Applications. The RT-XPC Series system can be built to meet Division 2 and/or Zone 2 in the: Condenser Section Only, Evaporator Section only, or both Condenser and Evaporator Section. Our Systems are Fully Tested for Operational Performance and Compliance. Units are Manufactured to N.E.C. and I.E.C. Explosion Proof Codes as well as CSA Certified RT-XPC Series Division II and Zone II Applications & BTU/HR Capacity 60 & 50 Hertz Models Standard Features All Electrical Components are UL Approved Explosion Proof Overload Protection on Motors and Compressors Easily Accessible Motor for fast and Convenient Service Non Sparking Condenser Fan and Blower designs Aluminum Fin and Copper Tube Coils for Maximum Heat Transfer Explosion Proof and General Purpose Operational Controls Ceiling Assembly Included with Air Filter Operation, Maintenance & Installation Manuals Included System Third Party Certified for use in Hazardous Locations by CSA International N.E.C. Rated and Approved Safe Air Technology Offering The Keys to Success: Quality, Pricing and On Time Delivery 4133 Evan Brooks Road Baton Rouge LA U.S.A Phone (225) Fax (225) sales@explosionproof.net COPYRIGHT 2014 Safe Air Technology LLC. All Rights Reserved 1 R1-0405

2 System Description Safe Air Technology RT-XPC series Units are fully tested for operational performance and compliance to ensure customer satisfaction. Our units are designed to provide cooling for Industrial severe duty applications. Our quality of engineering and manufacturing will ensure many years of reliable service. Please contact our sales engineering departments should you have any questions. We look forward to working with you and serving your needs for all of your HVAC/R Projects. Safe Air Technology, providing NEC Certificates of Conformance showing compliance with N.E.C. codes. If requested, SAT will provide an engineering submittal package for approval prior to manufacturing. System Applications Industrial Refineries Chemical Plants Offshore Platforms Gas Plants and Pipelines Corrosive and Hazardous Storage Facilities Ammunition Storage Bunkers Paint Rooms Fuel Transfer Docks and Pumping Stations Available Options -B -CC -CRT -EPX -MG1 -MG2 -SH4 -SH6 -SVI Group B Classification Copper Tube and Copper Fin Coils Export Crate for Sea or Air Shipping Epoxy Coated Metal (50HZ Units Only) Marine Grade Coating Condenser & Evaporator Coated Marine Grade Coating Coils & Sheet Metal Coated 304 Stainless Steel Housing 316 Stainless Steel Housing Service Port Installed Bottom Section Return Air Filter Installed This photo shows the controls for the unit when the blower and interior section must comply with Explosion Proof Codes. The bottom section is still put into place, but without the standard general purpose controls. This photo shows the standard bottom section for a General purpose blower section. Note that standard Controls remain. 2

3 RT-XPC Series [ 60 Hz. ] Class I, Groups C & D, Division 2 T-3 Model (1) 60 Hertz BTU/HR Power Supply Volts / Ph / Hz. Heating Wire Size (2) Fuse Size (3) Air Flow CFM RT-XPC N-CND-ICD2-*** 13, / 1 / N/A RT-XPC EH-CND-ICD2-*** 13, / 1 / RT-XPC N-AU-ICD2-*** 13, / 1 / N/A RT-XPC N-CND-ICD2-*** 15, / 1 / N/A RT-XPC EH-CND-ICD2-*** 15, / 1 / RT-XPC N-AU-ICD2-*** 15, / 1 / N/A RT-XPC Series [ 50 Hz. ] Class I, Groups C & D, Division 2 T-3 Model (1) 60 Hertz BTU/HR Power Supply Volts / Ph / Hz. Heating Wire Size (2) Fuse Size (3) Air Flow CFM RT-XPC (50)-N-CND-ICD2-*** 13, / 1 / N/A RT-XPC (50)-EH-CND-ICD2-*** 13, / 1 / RT-XPC (50)-N-AU-ICD2-*** 13, / 1 / N/A Notes: See Nomenclature for Unit ID ( 2 ) THHN 75 C Copper Wire ( 3 ) Delay Fuse or Approved Circuit Breaker ( *** ) Options that can be added. Contact our Sales Department should your specifications require a variation on our standard units. IMPORTANT NOTICE T Codes: It is important to know the auto ignition temperature of the Gas or Vapor the unit will be operating in or around. The Gas or Vapor temperature should be above the rating of the equipment. 3

4 System Dimensions Shipping Weights and Dimensions STANDARD PACKAGING SINGLE AND DOUBLE EXPORT CRATE Standard Packaging Data Single Crate Data Double Crate Data Length Width Height Weight Length Width Height Weight Length Width Height Weight LBS LBS LBS 4

5 RT-XPC N - CND- ICD2 - *** Roof Top Identification RT-XPC = Roof Top Capacity 13,500 = 13,500 BTU/HR 15,000 = 15,000 BTU/HR Unit Power Supply Options 1 = Volt / 1 Phase / 60 Hertz 2(50) = Volt / 1 Phase / 50 Hertz Heating Options EH = Electric Heat N = No Heat Area of Explosion Proofing for N.E.C. Classification CND = Explosion Proofing ONLY to Condenser Section AU = Explosion Proofing to All Sections of Unit Explosion Proof N.E.C. Classification Contact Our Sales Engineering Department for Classification Codes ICD2 = Class I, Groups C & D, Division 2 IBCD2 = Class I, Groups B, C & D, Division 2 Options Listed at End of Model Number - B = Group B Classification (B) - CC = Copper/Copper Coils Installed (CC) -CRT = Export Crate Included (CRT) -EPX = Epoxy Coated Metal (50HZ Units Only) (EPX) -MG1 = Marine Grade Coating Condenser & Evaporator Coated (MG1) -MG2 = Marine Grade Coating Coils & Sheet Metal Coated (MG2) -SH4 = 304 Stainless Steel Housing (SH4) -SH6 = 316 Stainless Steel Housing (SH6) -SVI = Service Port Installed (SVI) 5

RTXP2 Series - Division 1 OR 2 / Zone 0, 1,OR 2

RTXP2 Series - Division 1 OR 2 / Zone 0, 1,OR 2 RTXP2 Series - Division 1 OR 2 / Zone 0, 1,OR 2 Explosion Proof Hazardous Location Roof Top A/C Unit N.E.C and I.E.C. Approved for Explosion Proof Locations 50& 60 Hertz Models Capacity: 12,000-36,000

More information

VAC1 Series - Division 2 / Zone 2

VAC1 Series - Division 2 / Zone 2 VAC1 Series - Division 2 / Zone 2 Wall Mount Explosion Proof Air Conditioner System CSA Certified For Use in Division 2 Hazardous Locations 50 Hertz s 21,200 59,000 60 Hertz, High Ambient, & Custom Designs

More information

VAC1 Series-Division 2 / Zone 2

VAC1 Series-Division 2 / Zone 2 VAC1 Series-Division 2 / Zone 2 Wall Mount Explosion Proof Air Conditioner System CSA Certified For Use in Division 2 Hazardous Locations 60 Hertz s 21,200 59,000 60 Hertz, High Ambient, & Custom Designs

More information

VACPB1 Series - 60 Hz Models

VACPB1 Series - 60 Hz Models Manufactures of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems and Pressurization Equipment VACPB1 Series - 60 Hz s VACPB1 Series - 60 Hz s 1.5 to 6.0 (18,000 72,000 BTU/HR) Standard

More information

Capacity: 1.5 to 6.0 Ton

Capacity: 1.5 to 6.0 Ton VACPB1 Series Wall Mount Explosion Proof Air Conditioner and Room Pressurization System CSA Certified for Use in Division 2 Locations 60 Hertz Models 50 Hertz, High Ambient, & Custom Designs Available

More information

Capacity: 1.5 to 6.0 Ton

Capacity: 1.5 to 6.0 Ton VACPB1 Series Wall Mount Explosion Proof Air Conditioner and Room Pressurization System Hazardous Location N.E.C. and I.E.C. Approved 50 Hertz Models 60 Hertz, High Ambient, & Custom Designs Available

More information

CU-MS & AH-HW Mini-Split Series

CU-MS & AH-HW Mini-Split Series CU-MS & A-W Mini-Split Series Explosion Proof Mini-Split Air Conditioning System azardous Location N.E.C. and I.E.C. Approved 60 ertz Models : 12,000-36,000 /R General Purpose, Division I/II 50 ertz, igh

More information

Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment.

Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment. Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment. COPYRIGHT 2011 Safe Air Technology LLC. All Rights Reserved Severe Duty Design for: Safe

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C) The Norseman Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions. Norseman unit heaters are available

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.

More information

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series) Stars Management JLT SUBMITTAL EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series) Tel: 00971 (04) 457 2383 Fax: 00971 (04) 457 2382 P.O. Box: 25867 Dubai U.A.E. E-mail: info@starsmanagementjlt.com Website:

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

CF1 ProVector Explosion-Proof Heaters

CF1 ProVector Explosion-Proof Heaters CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

Comfort. Description. Applications

Comfort. Description. Applications Blower Heater 3-35 kw 10,00-119,40 Btuh 40 to 90 Volts, 50/0 Hz 31 Stainless Steel Case Shown 3 Phase ATEX, GOST, CE IIG Exd IIB T3 Description Type is designed to heat areas classified as hazardous locations

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986 ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Description. Applications

Description. Applications CXH-EP PDS CXHEP Convection Explosion Proof Heater Electric Blower For Hazardous Locations Unit for Hazardous 3 to 35kW 10,200 to 119,420 BYU/Hour NORTH AMERICAN RATINGS 208 to 600 Volts 1.8 to 9.0kW (T-2A)

More information

CWA4 Chilled & Hot Water Fan Coil

CWA4 Chilled & Hot Water Fan Coil CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Features/Applications Century Refrigeration s WIBR Series Unit

More information

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS -3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation

More information

Self-Contained & Split System Reverse Cycle Air Conditioners Models

Self-Contained & Split System Reverse Cycle Air Conditioners Models Self-Contained & Split System Reverse Cycle Air Conditioners Models 05-07-10-12-16-18-24 General Description Marvair's water source self-contained and split system reverse cycle air conditioners are designed

More information

EVLPF Series Compact Fluorescent

EVLPF Series Compact Fluorescent EVLPF Series Low Profile Hazard Gard Luminaires Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G Class III, Simultaneous Presence

More information

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat) ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400

More information

Self-Contained & Split System Reverse Cycle Air Conditioners Models

Self-Contained & Split System Reverse Cycle Air Conditioners Models Self-Contained & Split System Reverse Cycle Air Conditioners s 05-07-10-12-16-18-24 General Description Marvair's water source self-contained and split system reverse cycle air conditioners are designed

More information

Self-Contained Reverse Cycle Air Conditioners

Self-Contained Reverse Cycle Air Conditioners Self-Contained Reverse Cycle Air Conditioners Models MA 07-10-12-16-24 General Description Marvair's water source self-contained reverse cycle air conditioners are designed for use in either fresh or salt

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Self-Contained & Split System Reverse Cycle Air Conditioners SAB Self-Contained Units, CAB Condensers and DEAH Air Handlers

Self-Contained & Split System Reverse Cycle Air Conditioners SAB Self-Contained Units, CAB Condensers and DEAH Air Handlers Self-Contained & Split System Reverse Cycle Air Conditioners SA Self-Contained s, CA Condensers and DEAH Air Handlers General Description Marvair's water source self-contained and split system reverse

More information

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability- A Series Unit Coolers - Technical Catalog Product Benefits: T 3 $ Adaptability- Century systems go where others can t. Your Century system is engineered to meet your specific project application and job

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Portable Vertical Air-Conditioning and Heating Systems

Portable Vertical Air-Conditioning and Heating Systems Portable Vertical Air-Conditioning and Heating Systems Specifications for 10 Ton Units 208 230 volt 7 1 77 77 77 33 Front Side Back 77 71 / 77 Front 33 Side 2 Cabinet Features: Heating and Cooling Data:

More information

Burner Comparisons. Typical Competitor s Burner

Burner Comparisons. Typical Competitor s Burner Burner Comparisons INOV8 s Typical Competitor s Burner Automatic nozzle cleanout Yes No Available BTUs rated as input 100,000 to 1,000,000 76,500 to 500,000 Burner Motor - hp 1/5 1/7 Combustion safety

More information

KIC Air Curtains. Technical Guide

KIC Air Curtains. Technical Guide TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The

More information

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES TP TECH GUIDE TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP 1200-2000 CFM BLOWERS 3-5 TON COILS OPTIONAL ELECTRIC HEATERS ISO 9001 Certified

More information

SECTION (15767) - UNIT HEATERS

SECTION (15767) - UNIT HEATERS SECTION 23 82 39 (15767) - UNIT HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Unit Heaters. 2. Cabinet Unit Heaters. 3. Duct Heaters. 4. Baseboard Heaters. B. Related Sections: 1. Section

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP CATALOG 9-117.1 JUNE, 2003 TABLE OF CONTENTS Modine's TLP Series sets the industry standard for low intensity infrared heating performance

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

Center Mount Unit Coolers

Center Mount Unit Coolers CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4

More information

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2 Explosion Proof LED Light - Equivalent to 100-150 Watt Metal Halide - Class 1 Division 2 Part #: EPLC2-LED-150W Page: 1 Made in the USA The EPLC2-LED-150W LED hazardous area light fixture from Larson Electronics

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems. Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems. The DRY-30 Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features

More information

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal

More information

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( ) (N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS

More information

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. The DRY-40A Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features

More information

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION

More information

Super-Flo Low Profile Unit Cooler

Super-Flo Low Profile Unit Cooler Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

Installation Instructions

Installation Instructions 50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric

More information

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 18,000

More information

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN NH 3 Dual Discharge Evaporator Ammonia Industrial Applications 1-16 Tons MDAN > > U s e d f o r S m a l l t o m e d i u m I n d u s t r i a l A m m o n i a a p p l i c a t i o n s Manufactured with Stainless

More information

Q-TEC QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner Cooling Capacities: 13,3 to 49,3 BTUH (Based on EWT, GPM & CFM) Q-TEC QC-Series Chilled Water Air Conditioner The Q-TEC Series self-contained packaged chilled water air conditioner is designed to be installed

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

General Description. Operation

General Description. Operation ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication

More information

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS 48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT

More information

Thru-The-Wall THDC Series R-410A Condensing Units Ton Series

Thru-The-Wall THDC Series R-410A Condensing Units Ton Series Thru-The-Wall THDC Series R-410A Condensing Units 3-4-5 Ton Series M-Series Cabinet Available In 3 / 4 / 5 Ton M - SERIES FRONT VIEW STANDARD DESIGN High Efficiency Scroll Compressor Advanced Coil Design

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

SpaceKeeper Console (SKC)

SpaceKeeper Console (SKC) SpaceKeeper Console (SKC) With finished cabinet or custom enclosure SKC 008-015 ¾ - 1¼ tons 12 W x 25¼ H x 48 L CGC-09 SpaceKeeper Console R410A MODEL NO. SKC _ 008 010 012 015 Net Cooling Capacity - Rated

More information

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH MHWW NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Hi-Wall Fan Coil MHWW- 24 - H -1 2-Pipe Heat/Cool Heat/Cool Voltage 1=

More information

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH MHWW NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Hi-Wall Fan Coil MHWW- 09 - H -1 2-Pipe Heat/Cool Heat/Cool Voltage 1=

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner

More information

PA 500/1100V Ultra Quiet Ventilation Fan

PA 500/1100V Ultra Quiet Ventilation Fan SPECIFICATION SHEET PA 500/1100V Ultra Quiet Ventilation Fan Description Ultra quiet ventilation fan with high efficiency, capacitor start motor, Energy Star and HVI 2100 certified. The PA series is UL

More information

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz Product Data GEMINI SELECT 09DPS018-030,09DPM035-130 Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz 18 to 130 Nominal Tons (63 to 457 Nominal kw) a38-7096 09DPS030 UNIT WITH LOW SOUND OPTION

More information

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS 072, 090, 120, 180 & 240 MODELS C SERIES P SERIES HEAT PUMPS SPLIT L SERIES SYSTEMS LSA Condensing Units 6 Thru 20 Ton (21.1 Thru 70.3 ) Heat Pumps 7.5 & 10 Ton (26.4 & 35.2 ) Bulletin #210164 February

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation The Series convection heater, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The is available with either C CSA US or CE/ ATEX approvals.

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-Tec TM QC-Series Chilled Water Air Conditioner Q-Tec TM QC-Series Chilled Water Air Conditioner Cooling Capacities:, to, BTUH (Based on EWT, GPM and ) The Q-Tec Series self-contained packaged chilled water air conditioner is designed to be installed

More information

Indoor Air Handlers with Compressors MVS and MVW

Indoor Air Handlers with Compressors MVS and MVW Indoor Air Handlers with Compressors MVS60-90-120-144 and MVW60-90-120-144 General Description The Marvair Marine self-contained water and air cooled air conditioners are designed for both new installations

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

T P A 120 S 4 S N 1 Y

T P A 120 S 4 S N 1 Y PRODUCT SPECIFICATIONS HEAT PUMP OUTDOOR UNITS TP T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TPA-090-120 (11/2012) EER up to 11.0 7.5 to 10 Tons Cooling Capacity - 89,000 to 180,000 Btuh Heating

More information

16 SEER TWO-STAGE AIR CONDITIONERS

16 SEER TWO-STAGE AIR CONDITIONERS FORM NO. ATZ-210 Supersedes Form No. ATZ-210 16 SEER TWO-STAGE AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems Mission Critical Air Conditioning Systems vertical floor mount Series 6, 8 & 9 2-30 Ton Units Single Circuit for Superior Economy and Dual Circuit for Ultimate Protection Series 6 2-5 tons Compact Footprint

More information

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths Product Description The XB, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The XB is available with either CSA C/US or CE/ATEX approvals.

More information

TZPL SERIES. Applications Thermal Zone remote heat pumps offer comfort and dependability for single, multi-family and light commercial applications.

TZPL SERIES. Applications Thermal Zone remote heat pumps offer comfort and dependability for single, multi-family and light commercial applications. FORM NO. PTZ-786 Supersedes Form No. PTZ-765 Rev. 2 TZPL SERIES Manufactured for Thermal Zone Philadelphia, PA 13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum fins.

More information

CENTRAL SPLIT UNIT UNIC

CENTRAL SPLIT UNIT UNIC CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products

More information

Corporation , Soraji-ro, Paju-si, Gyeonggi-do, Republic of Korea (Postal Code: 10863)

Corporation , Soraji-ro, Paju-si, Gyeonggi-do, Republic of Korea (Postal Code: 10863) Corporation Company Information 01 Company Gfutec Corporation. (October. 08th, 2009.) 02 Location Head Office 34-, Soraji-ro, Paju-si, Gyeonggi-do, Republic of Korea (Postal Code: 10863) 03 Contact Tel

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information