C-10 Probetester Operator manual Operator Manual

Size: px
Start display at page:

Download "C-10 Probetester Operator manual Operator Manual"

Transcription

1 Operator Manual Dokument ID: T60003J Page 1of 44 Issue J /

2 Table of contents Page 1 Introduction 3 2 Installation 4 3 Water filter 5 4 Getting started 6 5 Using the C-10 Probetester Program settings Setting the sensors Temperature sensor Threshold values Manual mode Other Settings Log Printer information Cleaning & maintenance Self disinfection Troubleshooting Technical specifications Accessories & spare parts Certificate of Conformance Contact information 44 Dokument ID: T60003J Page 2of 44 Issue J /

3 1. Introduction The C-10 Probetester is designed with the following intended use: To measure occurring leakages through the outer isolation layer in ultrasound probes and to indicate if by the user set values are exceeded. The measuring is done during a disinfection process, which is specified by the user. C-10 Probetester is a CE-marked product certified to the Medical Device Directive 93/42/EEC, annex II as a class IIb medical device which in applicable parts follows ISO :2008. The quality management system of Optima Scandinavia AB Hospital Equipment Division is certified to SS-EN ISO 13485:2003. It is important to follow the probe manufacturer s instructions regarding what disinfection solution to use and to follow the instructions from the manufacturer of the disinfection solution for appropriate settings for disinfecting and rinsing. It is also important to follow instructions on how to clean the probe before it is connected to the C-10. The C10-probetester will not replace the safety-test according to your hospital standards. If the C10-probester indicates an electrical leakage on the probe it is important that further tests are being carried out by certified engineers. If the instructions in this operator s manual are not followed, the warranty will not be valid. Optima can not be held responsible for any damage to the probes. In case of malfunction be aware that only certified personnel are allowed to service the equipment. C-10 Probester is tested and validated for use with the following disinfection fluids: Cidex OPA Gigasept FF Gigasept Forte Vircon Perasafe Korsolex Extra, Sekusept Plus Before using any other disinfection fluids Optima must be consulted. The C-10 Probetester is designed and manufactured by Optima Scandinavia AB. If problems should occur please contact your local distributor or Optima Scandinavia AB. Please refer to the following information about your C-10 Probetester when corresponding to Optima Scandinavia or your local distributor. Part. No: Serial No: Dokument ID: T60003J Page 3of 44 Issue J /

4 2. Installation The C-10 Probetester is designed to be mounted onto a wall by two bolts. The equipment weighs 40 kg so make sure to use the appropriate bolts. Use stoppers if needed. Recommended distance from the floor level to the mounting brackets on the equipment is 1800 mm. It is important to connect the air filter to the exhaust ventilation system of the room. If there is no existing exhaust ventilation system available it is recommended to connect the hose to outside air. If the dimensions do not match, use an adaptor. Water and drains must be connected by a professional or a certified plumber. Caution! Make sure that main power is turned off before installation. Connect fresh water to the inlet on the equipment (marked inlet). Use a suitable hose of 8 mm inside diameter. The inlet is located inside the door at the bottom of the equipment (see fig. 1). Connect a suitable hose for drainage with an inside diameter of 22 mm (marked drain). The drainage is located at the bottom of the equipment (see fig. 1). Connect a suitable hose to drain single-use with an inside diameter of 22 mm (marked single-use). The single-use drainage is located at the bottom of the equipment (see fig. 1). Consult the local hygienic department where to connect the single-use drainage. Connect the exhaust filter (HK22) to the transparent vent pipe on the top of the equipment. Connect the filter to the ventilation system. The supplied electrical mains cable should be connected to the V electrical power inlet. The power inlet is located on the right hand side of the equipment. Fig. 1 Vatten to drain Single use Water inlet to drain Dokument ID: T60003J Page 4of 44 Issue J /

5 3. Water filter The equipment ihas a water filter installed. The sterilisation level of the filter is 0,2 um and it has to be replaced every three months. The filter has a quick-connect design and is easy to change. If the water is unusually unclean the equipment will alarm for filling time exceeded in the rinsing process and the filter has to be replaced, even before three months time has passed. This is displayed on the screen as described below. To turn off the alarm, press Ok. To print out a receipt press Receipt, if no receipt is desired press Ok again :35: Fill time exceeded Ok Receipt Dokument ID: T60003J Page 5of 44 Issue J /

6 4. Getting started Fill the container with disinfection solution. Use only disinfection solution approved and tested by the manufacturer of the probes. Follow the instructions from the manufacturer of the disinfection solution regarding concentration. Program the equipment with the appropriate settings for disinfecting and rinsing according to the manufacturer of the disinfection solution (see page 7 for program settings). It is important that the disinfection process also follows any national standards deviating from SS-ISO When handling disinfection solution carefully follow the safety instructions from the manufacturer of the disinfection solution. Verify that there is at least 2 litres of disinfection solution in the container before each use. Also check that the solution has not passed the best-before date. It is important to clean the probe according to the probe manufacturers instructions before the probe is connected to the C-10 Probetester. If the probe is not properly precleaned there is a possibility that blood/mucus may cause a malfunction. Note! It is the users responsibility to make sure the equipment is properly programmed for the disinfection solution that is being used. The disinfection solutions concentration, effectivity and durability must be verified (ie. test stripes). Note that the plastic tube may get miscoloured from the disinfection fluid after long use! When using the standard program (Std) the disinfection solution is reused. It is important to follow the instructions from the manufacturer of the disinfection solution when reusing disinfection solution. Settings for number of days or cycles to change canister should be done according to instructions (see page 28). In case of an alarm during the process, make sure to control and correct the error and inform responsible personnel about the alarm code (see page 40). To turn off the sound from the alarm press any of the buttons. Then, press OK or Receipt to restore the alarm. In case of main power failure the equipment will automatically pump out the fluid to the preset drain and will indicate with an alarm message on the display when the main power is restored. This process has been developed to protect the probe from over exposion from the disinfection solution. Note! After a disrupted cycle following an alarm or power failure the testand disinfection process must be performed again. Dokument ID: T60003J Page 6of 44 Issue J /

7 5. Using the C-10 Probetester Turn ON the equipment by pressing the main switch key on the upper front, the display will then start-up. After switching the equipment OFF, it is important that you wait at least 10 seconds before switching it on again. While showing C-10 probetester on the display the equipment will automatically perform a self-test. During the self-test the software version number is shown on the display (important information for service) and after a successful self-test the following is shown on the display: :23:00 Place probe Standard Selfdes. Single use Menu First enter the menu and set the values according to the instructions from the manufacturer of the disinfection solution (see chapter 6 Program settings). Carefully place the probe in the transparent plastic tube. Caution! Contamination can be transferred from an earlier used probe if the probe gets in contact with the edges on top of the tube or the stainless steel nozzles. It is therefore very important to manually disinfect these parts after connecting the probe. Use a wipe only with disinfection solution that is compatible with acrylic. Adjust the probe handle above the transparent plastic tube. It is important that the tip of the probe is able to move freely 360 degrees. Connect the probe connector to the equipment. Some probes have a locking device which in such cases should be used. To start the measuring process press either the Standard program key or the Single-use program key. The Standard program will return the disinfection solution to the container and the Single-use program will send the disinfection solution directly to the drains or to an installed separate container. The selected program will be shown on the display. Dokument ID: T60003J Page 7of 44 Issue J /

8 5.1 Standard program To start the standard program press Standard followed by Start. To return to menu press Stop. Standard program Start Stop The equipment will now start to measure the electrical leakage while the probe is in the disinfection solution. The display will indicate the electrical leakage in µa as well as ongoing process and remaining time for the complete process. Measure/disinf 20: μa 15% Stop After the measuring process the rinsing process starts automatically. Rinsing 08:00 Stopp 59% Dokument ID: T60003J Page 8of 44 Issue J /

9 When the process is finished the result of the leakage test is indicated on the display. Print a receipt for documentation by pressing Receipt. Process ready Probe OK Acknowledge w. receipt Receipt Stop 5.2 Single use To start the single use program press Single use followed by Start. To return to menu press Stop. Thereafter the process will be the same as for standard program but the used disinfection fluid is pumped to drain. att använd desinfektionsvätska pumpas till avloppet After finished process the probe should be removed from the plastic tube to dry. If there is a leakage of more than the set threshold value the probe has failed the electrical safety test. In such case contact technical personnel for further testing. Dokument ID: T60003J Page 9of 44 Issue J /

10 6. Program settings In order to change the program settings press the menu key. To access the menu enter the password code. Caution! Changing the program settings may affect the outcome of the process. Before changing any settings, please consult the responsible personnel. The equipment should be programmed with the appropriate settings for disinfecting and rinsing according to the manufacture of the disinfection solution. The probe testing device timer is programmed by the manufacturer accordingly: Filling time disinfection solution: 35 seconds Filling time H 2 O: 35 seconds Measuring process: 20 minutes Empty time: 35 seconds Rinse time: 10 minutes Pause rinsing time: 3 seconds Test level: SensorU (upper): 60 SensorL (lower): 80 Min. temp: 18 C Max. temp: 26 C Trim temp: 22 C Pump effect: 8 Printer: ON Pressure regulator: 1,5-2 bar Changes made in the settings will be saved and it will not return to the manufacturer program settings. To go to the menu, press Menu :23:01 Place probe Standard Self des Single use Menu Dokument ID: T60003J Page 10of 44 Issue J /

11 Password To enter the menu press the code. If no code is registered within 15 seconds, the menu for changing canister will appear. Password After entering correct password the menu appears. To change program settings, press Program. Menu Program Other Log Values Delete log To go back one step in the menus, press. To go forward one step in the menus, press. Dokument ID: T60003J Page 11of 44 Issue J /

12 6.1 Changing disinfection filling time To change the disinfection filling time press or. Prg fill dis 40s 6.2 Changeing water filling time To change the water filling time press or. Prg fill water 35s Dokument ID: T60003J Page 12of 44 Issue J /

13 6.3 Changing measuring process time To change the measuring process time (time in disinfection solution) press or. Prg measuring time 15m 6.4 Changing self disinfection time To change the self disinfection (SD) time press or. Prg SD time 15m 6.5 Changing emptying time To change the emptying time press or. Prg emptying time 35s Dokument ID: T60003J Page 13of 44 Issue J /

14 6.6 Changing rinsing time To change the rinsing time press or. Prg rinsing time. 10m 6.7 Changing pause time To change the pause time press or. Prg pause time 2s Dokument ID: T60003J Page 14of 44 Issue J /

15 7. Setting the sensors As a safety measue the C-10 Probetester is equipped with two separate sensors in the plastic tube that must be calibrated to adjust to different disinfection solutions. Before using the C-10 Probetester the sensitivity of the sensors must be set. To go to menu, press Menu :23:01 Place probe Standard Self dis. Single use Menu Password To enter the menu press the code. If no code is registered within 15 seconds, the menu for changing canister will appear. Password After entering correct password the menu appears. Since the measuring is performed in disinfection fluid, the plastic tube must first be filled with water. The differences between measuring in water or disinfection fluid are To go back one step in the menus, press. To go forward one step in the menus, press. Dokument ID: T60003J Page 15of 44 Issue J /

16 7.1 Manual filling of water To fill the plastic tube manually, press Program. Menu Program Other Log Values Delete log Press or to go to the program for Manual rinsing valve. To open the rinsing valve and fill water manually, press On. Fill water a few millimetres over the metal top of the small white sensor in the upper plastic cup. Stop filling by pressing Off. Man rinsing valve OFF On Off Dokument ID: T60003J Page 16of 44 Issue J /

17 7.2 Sensor sensitivity To change the sensors sensitivity go to the menu and press (threshold) Values. Menu Program Other Log Values Del. log Adjusting the lower sensors sensitivity The measured value is shown on the left side. Set the right hand value to appr. 80% of the measured value. The manufacturer setting is 60. To change the value press or. LowerL Caution! If the sensor is not set correctly this can result in a malfunction. Dokument ID: T60003J Page 17of 44 Issue J /

18 Adjusting the upper sensors sensitivity. The measured value is shown on the left side. Set the right hand value to appr. 60% of the measured value. The manufacturer setting is 80. To change the value press or. UpperL Caution! If the sensor is not set correctly this can result in a malfunction. 7.3 Manual water drain To manually drain the water, press On or Off. Man drain water OFF On Off Dokument ID: T60003J Page 18of 44 Issue J /

19 8. Temperature sensor The C-10 Probetester is equipped with a temperature sensor in the disinfection solution canister. The temperature sensor checks that the temperature of the disinfection solution is within the limits recommended by the disinfection solution manufacturer. The temperature sensor does not regulate the temperature, it only indicates if the temperature of the disinfection is out of the set values. Note! Check the disinfection fluid manufacturers advices regarding operating temperature of the disinfection fluid. 8.1 Adjusting the lower limits for the disinfection solution temperature Check the lowest useable temperature that is permitted with the used disinfection fluid. To change the value press or. If the temperature of the disinfection fluid is lower than the set value, the process will not start. Min Temp. 18C 8.2 Adjusting the upper limits for disinfection solution temperature Check the highest useable temperature that is permitted with the used disinfection fluid. To change the value press or. If the temperature of the disinfection fluid is higher than the set value, the process will not start. Max Temp. 25C Dokument ID: T60003J Page 19of 44 Issue J /

20 8.3 Calibration of the temperature sensor Calibrate the temperature sensor in relation to room temperature by entering the actual room temperature. A press on or will change the temperature with 1/10 degree, but the display will only show the integer. Trimtemp. 22C Dokument ID: T60003J Page 20of 44 Issue J /

21 9. Threshold values The C-10 Probetester can be equipped with up to four different connectors for ultrasound probes. Every connector can be set to an individual threshold value for the electrical leakage level. Password To enter the menu press the code. If no code is registered within 15 seconds, the menu for changing canister will appear. Password After entering correct password the menu appears. To change program settings, press Program. Menu Program Other Log Values Delete log Dokument ID: T60003J Page 21of 44 Issue J /

22 9.1.1 Changing test level 1 To change the threshold value for electrical leakage measured in μa för probe connector 1, press or. Test level Changing test level 2 To change the threshold value for electrical leakage measured in μa för probe connector 2, press or. Test level Changing test level 3 FTo change the threshold value for electrical leakage measured in μa för probe connector 3, press or. Test level Dokument ID: T60003J Page 22of 44 Issue J /

23 10. Manual settings The manual settings enable the operator to manually control the filling and emptying of the plastic process tube for maintenance work and after a malfunction. It is highly recommended that the operator has sufficent skills of operating the C-10 Probetester before using the manual settings as the automatic overflow and alarm systems are bypassed Opening of the rinsing valve To manually open the rinsing valve, press On or Off. Man rinsing valve OFF On Off 10.2 Filling the rinsing tube To fill the plastic tube with disinfection fluid manually, press On or Off. Man Fill des OFF On Off Dokument ID: T60003J Page 23of 44 Issue J /

24 10.3 Manual emptying of disinfection fluid To empty the disinfection fluid back to the container manually, press On or Off. Man empty dis OFF On Off 10.4 Manual water drain To manually drain water press On or Off. Man drain water OFF On Off Dokument ID: T60003J Page 24of 44 Issue J /

25 10.5 Manual single use disinfection solution drain To manually drain single use disinfection solution press On or Off. Man drain single use OFF On Off Dokument ID: T60003J Page 25of 44 Issue J /

26 11. Other settings C-10 Probetester has an automatic function to remind the user of changing the disinfection solution canister. To manually set the time for canister replacement, press Menu and enter the password. If no code is registered within 15 seconds, the menu for changing canister will appear. Password After entering correct password the menu appears. To change time setings for canister change, press Other. Menu Program Other Log Values Delete log To manually set the canister change to cycles, days or - press or. When selecting cycles or days the C-10 Probetester will alarm when canister is to be changed. When selecting - the C-10 will not alarm. Dokument ID: T60003J Page 26of 44 Issue J /

27 11.1 Canister change days Canister change DAYS To manually change the number of days the disinfection solution can be used, press or. Max days 14 Dokument ID: T60003J Page 27of 44 Issue J /

28 11.2 Canister change hours Canister change HOURS To manually change the number of hours the disinfection solution can be used, press or. Max hours 14 Dokument ID: T60003J Page 28of 44 Issue J /

29 11.3 Canister change cycles Canister change CYCLES To manually change the number of cycles the disinfection solution can be used, press or. Max cykles Canister change - To manually shut of the canister change function choose -. Canister change - Dokument ID: T60003J Page 29of 44 Issue J /

30 11.5 Changing disinfection solution This menu below will appear on the display when it is time to change disinfection solution. Press Receiptto see when the latest canister change was performed. Press New and then Receipt to verify that the canister is changed. New canister OK Receipt New 11.6 Changing language To change language, press or. Language English Dokument ID: T60003J Page 30of 44 Issue J /

31 11.7 Setting the date To set the date press or to move through year/month/day. To change the date press or. To move one step in the menu press again after day. Date Setting the time. To set the time press or to move through hours/minutes/seconds. To change the time press or. To move one step in the menu press again after seconds. Time 15:21:00 Dokument ID: T60003J Page 31of 44 Issue J /

32 11.9 Changing the pump effect To change the pump effect, press or. The range goes from 0-15 where 0 is the lowest and 15 the highest pump effect setting. Note! A high pump effect value gives a low noise level and vice versa. Pump effect Printer settings To turn the printer On or Off, press or. Printer ON Dokument ID: T60003J Page 32of 44 Issue J /

33 10.11 Bar code reader settings To turn the bar code reader (scanner) printer On or Off, press or. Bar code reader ON Setting the MAC-address To change the MAC-address, cycle with or and change with or. MAC Setting the IP-address To change the IP-address, cycle with or and change with or. IP Dokument ID: T60003J Page 33of 44 Issue J /

34 12. Log C-10 Probetester is equipped with a log that saves the test results from the latest runs. The log cam be printed or transferred to other equipment through IP- and MAC settings. To access the log, press Log. The same resullts as on the receipt will be shown. A list of error messages can be found in chapter 16 of this manual. Menu Program Other Log Values Delete log C-10 Probetester Disinfection: Passed Test results Disinfections time: Date: m Time: 15:23:01 Rinsing: Passed Rinsing time: 10 min Prob no: Probe test: Passed (5000 µa) 246 µa Dokument ID: T60003J Page 34of 44 Issue J /

35 13. Printer information Introduction Printouts are available to fully document the process and to facilitate traceability. The printer is a 50 mm, 5V, Easy Loading Printing Module. The printer will indicate with a red line on the paper when it is time to change the paper roll. If paper is missing the red light will start blinking (3 short, paus, 3 short etc.). To deactivate the printer press the right button (pause) and the LED will indicate pause by blinking. To reactivate press the right button again (pause) and the LED will indicate with a constant red light. To feed paper press the left button (feeding). Notice! The printer paper is not of a permanent archival type. Stability over long time archiving can not be guaranteed. Available printouts Available printouts are; date, time, measuring/disinfection pass/fail, rinsing pass/fail, probe test pass/fail, change of disinfection solution and alarmcodes. The sections that form the printer are described in the following image. 1. Printer mechanism, easy loading type 2. Paper roll housing 3. Cover, with Lever and Roller 4. Tear Bar, for paper cutting 5. Control panel with two push buttons and one LED 6. Electronic Control Board Dokument ID: T60003J Page 35of 44 Issue J /

36 Opening the cover Pull the lever until the cover is released from its locking position. To avoid damages to the lever do not use excessive force. Loading paper rolls Step 1 Step 2 Closing the cover correctly Press on both sides of the cover simultaneously Cutting the paper correctly Pull the paper towards the Tear Bar from one side to the other. Dokument ID: T60003J Page 36of 44 Issue J /

37 14. Cleaning and maintenance The outer case of the C-10 Probetester is made of stainless steel and can be cleaned using a wipe or cloth with a mild soap solution. Please be aware that the plastic tube and the keypad must not be exposed to any alcohol based products or any other strong cleaning detergents. If the plastic tube is repeatedly exposed to alcohol there is a risk that cracks will appear as a function of time. The tube does not tolerate alcohol based solutions with an alcohol content over 12%. Caution! If the keypad or the plastic tube is cleaned with alcohol based products the surface may be damaged. To prevent possible malfunction maintenance should be performed periodically. Personnel operating the equipment should control the following before every use: 1) Check that the level of disinfection solution in the container is at least 2 litres. 2) Make sure that the plastic tube is not cracked. 3) Check for obvious leakage. Within a 12 month interval or in case of suspected malfunction the following should be controlled: 1) An Electrical Safety Test should be performed by certified hospital/clinic personnel. 2) Test of electrical leakage with the 1MΩ test device delivered together with the equipment. The test device is connected between the inside of the upperplastic cup (make sure that the it is in contact wit the fluid) and with the metal tongue of one of the the probe connectors. Should be performed periodically by personnel certified by Optima or an Optima representative. Within a 24 month interval the following maintenance should be performed: 1) Cleaning of the pump membranes. Should be performed periodically by personnel certified by Optima or an Optima representative. 2) Cleaning of the valves. Should be performed periodically by personnel certified by Optima or an Optima representative. 3) Changing the plastic tube, if needed. Should be performed periodically by personnel certified by Optima or an Optima representative. Caution! Contamination can be transferred from an earlier used probe if the equipment is not properly cleaned. Dokument ID: T60003J Page 37of 44 Issue J /

38 15. Self disinfection The C-10 Probetester is designed to be able to perform self disinfection (SD). This should be done periodically in consultation with the hospital hygiene department that will decide what solution to use as well as disinfection time to guarantee an approved process. The procedure is to use another disinfection solution for self disinfectin the equipment than normally used to disinfect the probes. This is done to prevent resistent bacteria to grow in the equipment. Connect a canister with self disinfection solution and press SD in the menu to start the self disinfection process. The equipment will select the preset time settings. If other settings are required the equipment must be reprogrammed by the user before the self disinfection process. Self disinfection started 08:52 Stop 15% The parts that will be disinfected are all the parts that will normally be in contact with the disinfection solution; hoses, pumps, vents and the disinfection tube. If bacteria should grow in the rinse water pipes in the equipment, the water pipes should be flushed with disinfection solution and thereafter rinsed. This means that the inlet water should be disconnected and the solution flushed manually through the pipes with valve V1 open. Optima can not be held responsible for any water filtration systems outside the C-10 Probetester. Dokument ID: T60003J Page 38of 44 Issue J /

39 16. Troubleshooting & alarm codes Alarm codes/fault Possible cause Solution 10 Fill time (filling Filling time too short. the fill up time time exceeded in the measuring process). Level of disinfections Fill up or change solution is too low. disinfection solution. Hoses are kinked or Adjust the hoses. jammed. Membrane pump out of function. Turn off the equipment and contact certified personnel. Solenoid valve does not open. Turn off the equipment and contact certified personnel. Major leakage Turn off the water inlet and contact certified personnel. 11 Fill time (filling time exceeded in the rinsing process). 12 Empty time (emptying time exceeded in the measuring process). 13 Empty time (emptying time exceeded in the rinsing process). Filling time too short. Incoming flow rate too low. Incoming water pressure too low. Hoses are kinked or jammed. Solenoid valve does not open. Major leakage Emptying time too short. Hoses are kinked or jammed. Membrane pump out of function. Solenoid valve does not open. Major leakage Emptying time too short. Hoses are kinked or jammed. Membrane pump out of function. Solenoid valve does not open. Major leakage the fill up time. Turn the needle valve anticlockwise. Turn the pressure regulator clockwise. Adjust the hoses. Turn off the equipment and contact certified personnel. Turn off the water inlet and contact certified personnel. the emptying time. Adjust the hoses. Turn off the equipment and contact certified personnel. Turn off the equipment and contact certified personnel. Turn off the water inlet and contact certified personnel. the emptying time. Adjust the hoses. Turn off the equipment and contact certified personnel. Turn off the equipment and contact certified personnel. Turn off the water inlet and contact certified personnel. Dokument ID: T60003J Page 39of 44 Issue J /

40 Alarm codes/fault Possible cause Solution 16 - Leakage (leakage in Major leakage. Turn off the equipment and the measuring process). contact certified personnel. 17 Leakage (leakage in the rinsing process). 18 Power failure (power failure in the measuring process). 19 Power failure (power failure in the rinsing process). 20 No probe Major leakage. Failure in main power supply. Failure in main power supply. The probe is not connected. Turn off the water inlet and contact certified personnel. The equipment will automatically start when the power is back on. The equipment will automatically start when the power is back on. Connect the probe. 21 Temperature out of range The temperature of the disinfection solution is either too high or too low. Connect the probe. Caution! A leakage or a broken hose may cause leakage of hazardous disinfection fluid. Dokument ID: T60003J Page 40of 44 Issue J /

41 16. Technical specifications for C-10 Probetester Dimensions: Weight: Electrical supply: Noise level: Height 1650 mm Width 510 mm Depth 250 mm 40 kg V AC, HZ, 50 W Appr. 60db Applied Standards: EN :2001 IEC :2006 SS-EN ISO : /43/EEC Annex II (Class IIb, rule 15) Operating temp.: Disinfection solution volume: Water consumption: Water pressure: Room temperature 1,4 litres per cycle 1,4 litres per cycle 2-6 BAR Dokument ID: T60003J Page 41of 44 Issue J /

42 17. Accessories & Spare parts Options: T8000X Extra probe connector Spare parts T10019 T10028 T30002 T30008 T50012 T80001 T10025 T10026 Control board C-10 Touch Tank connector Membrane pump Solenoid valve Tubing set Transparent plastic tube Sensor, upper Sensor, lower Consumables: T50001 Printer paper Dokument ID: T60003J Page 42of 44 Issue J /

43 19. DECLARATION OF CONFORMITY C-10 Probetester Operator manual The undersigned, representing the following manufacturer Name: Optima Scandinavia AB Address: Gunstagatan 16, SE Uppsala, Sweden Telephone no: +46 (0) Telefax no: +46 (0) herewith declares that the product Type of equipment: Probetester for ultrasound probes Brand name: C-10 Probetester Model/Type: Serial number: and higher complies with LVFS 2003:11 which is the Swedish implementation of the Medical Device Directive 93/42 EEC. The following standards (or parts thereof) and/or technical specifications have been applied - harmonized standards: No Issue Subject EN Electrical safety testing for measurement and laboratory devices IEC Electrical equipment for measurement, control and laboratory us EMC requirements - Part 1: General requirements EN ISO Washer desinfectors- Part 4:Requirements and test for washer-disinfectors employing chemical disinfection for thermolabile endoscopes Product category: Disinfection of other medical devices Class: II b The Declaration of conformity is issued according to the Medical Device directive 93/42 EEC Annex II (Full quality assurence system). Uppsala place date signature /Jens Pettersson, CEO name and function Dokument ID: T60003J Page 43of 44 Issue J /

44 20. Contact information Sales & service Optima Scandinavia AB Gunstagatan 16 SE Uppsala Sweden Dokument ID: T60003J Page 44of 44 Issue J /

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Manual v1 Page 1 of 19. Manual. Laboratory autoclave Manual 20.2.2015 v1 Page 1 of 19 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav

More information

CER-1 & CER-2 Installation & Testing Instructions

CER-1 & CER-2 Installation & Testing Instructions CER-1 & CER-2 Installation & Testing Instructions i Read all installation instructions completely before installing this device. 1 2 3 INTRODUCTION This document details the installation procedure for

More information

Installation manual Washer extractor

Installation manual Washer extractor Installation manual Washer extractor W555H Type W.55.H Original instructions 438 9054-30/EN 2017.11.06 Contents Contents 1 Safety Precautions...5 1.1 General safety information...6 1.2 Commercial use

More information

MIX Boiler & Font Range Service Manual

MIX Boiler & Font Range Service Manual MIX Boiler & Font Range Service Manual 1000870# 1000871# 1000875# 1000880# 1000887# 1000878 1000879 2300268 www.marcobeveragesystems.com Ireland Tel: +353 (1) 295 2674 UK Tel: +44 (0207) 2744577 Service

More information

B 353 COFFEE BREWING MACHINES MACHINES A CAFE KAFFEEBRUEHMASCHINEN KOFFIEZETAPPARATEN

B 353 COFFEE BREWING MACHINES MACHINES A CAFE KAFFEEBRUEHMASCHINEN KOFFIEZETAPPARATEN Chiller A B C1 C2 C3 C4 C D E L H G F J M I K N Fig. 1 Principal components and Control organs E=154 W=78 115 572 755 200 35 482 415 245 E/W = 61 Fig. 2 Dimensions Bravilor Bonamat GB Operating instructions

More information

Manual Page 1 of 8. Manual. Laboratory autoclave

Manual Page 1 of 8. Manual. Laboratory autoclave Manual 17.11.2014 Page 1 of 8 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav

More information

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0 x HANDS-ON MODULE 5 CLEANING FLOW-i V3.0 Before cleaning BEFORE CLEANING CLEANING PROCEDURES OVERVIEW Cleaning procedure when a bacterial/viral filter IS used Cleaning procedure when NO bacterial/viral

More information

USER MANUAL AND TECHNICAL MANUAL

USER MANUAL AND TECHNICAL MANUAL USER MANUAL AND TECHNICAL MANUAL Kanmed Universal Warming Cabinets Kanmed Blanket Warming Cabinets Kanmed Combination Cabinet GE-2300-070 / 4 2014-05-12 NOTE: This manual contains important information

More information

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features: Top Loading Autoclaves (95, 120, 135 L) The Top Loading Autoclave range features: A choice of 63, 95, 120 and 135 litres models A fully programmable 5,7 Touch Screen Colour Controller Timed/Pulsed Free

More information

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at PHASE ROTATION METER 6608 L1/A L2/B 690V 600V CAT III 300V CAT IV L1L2L3 L3/C L R PHASE ROTATION MODEL 6608 User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431

More information

Getinge 8666/8668 Washer Disinfectors

Getinge 8666/8668 Washer Disinfectors Getinge 8666/8668 Washer Disinfectors Product specification PRODUCT The Getinge 8666/8668 are fully automatic, microprocess controlled, washer disinfectors. The washers are identical except for the depht

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Paraffin Wax Embedding Centre MPS/P2 INS3100GB 03-2011-06 Instructions MPS/P2 1 Instructions MPS/P2 2 CONTENTS 1. INTENDED USE... 4 2. SYMBOLS... 4 3. SAFETY NOTES... 4 4. COMPONENTS...

More information

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original Wireless Document in original -en_gb language 2017-03-20 A004 Contents 1 Declaration of Conformity... 1 2 Product description... 3 3 Guidelines for installation... 4 4 Operation... 5 5 Interface Description...

More information

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems INSTALLATION MANUAL GUTHD2 Universal Two Way Digital Thermostatic Valve for Shower Systems IMPORTANT: To ensure this product is installed properly, you must read and follow these guidelines. The owner/

More information

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control manual W365H, W375H, W305H, W330H, W380H, W3240H, W3300H Exacta & Clarus Control 438 9200-0 06.34 Contents 3 Contents Technical data... :... 2: Transportation and unpacking... 2: Siting and floor... 3:

More information

Engineers manual. Under counter machines

Engineers manual. Under counter machines Table of Contents 1. INTRODUCTION... 3 1.1 1.2 1.3 INSTALLATION AND COMMISSIONING... 3 SERVICE AND REPAIRS... 3 MODIFICATION... 3 2. EXPLANATION OF SYMBOLS USED... 3 3. WARNING AND SAFETY INFORMATION...

More information

Short Instruction for Use for in-home care ASSKEA procuff M and ASSKEA procuff S

Short Instruction for Use for in-home care ASSKEA procuff M and ASSKEA procuff S Short Instruction for Use for in-home care ASSKEA procuff M and ASSKEA procuff S 0843 AS TO ELECTRICAL SHOCK, FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH ANSI/AAMI ES60601-1 (2005), CAN/CSA-C22.2

More information

Mix Boiler & Font Range ( #, #, #, , )

Mix Boiler & Font Range ( #, #, #, , ) Mix Boiler & Font Range (1000870#, 1000871#, 1000880#, 1000878, 1000879) Service Manual Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ireland

More information

Edition 6, From serial no Publ. no Orwak 5030-CE. Operating manual

Edition 6, From serial no Publ. no Orwak 5030-CE. Operating manual Edition 6, From serial no. 78087 Publ. no 4869700-00 2008-01 Orwak 5030-CE Operating manual English CONTENTS Safety...8 2 Operating instructions...9 3 Technical specifications...10 4 Dimensional sketch...10

More information

Control of the system, MLP RO pump station

Control of the system, MLP RO pump station Control of the system, MLP RO pump station Operating instructions TI071GB-02 /06.11.09/LJ 1/12 Table of contents Humidification pump Safety equipment Selecting RO type Choice of language Normal indications

More information

Trident User s Manual

Trident User s Manual Labkotec Oy Myllyhaantie 6 33960 Pirkkala FINLAND Tel. +358 (0)29 006 260 18.05.2017 Fax +358 (0)29 006 1260 Internet: www.labkotec.fi 34 pages Trident Copyright 2017 Labkotec Oy 1/34 TABLE OF CONTENTS

More information

Hygea Hygea Hygea

Hygea Hygea Hygea Hygea 2 Operator InstructionManual Contents Contents... 1 Safety instructions... 2 Quick guide... 3 Operator instructions... 4 Cycle abort messages... 11 Draining the tank... 14 Changing printer paper...

More information

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS PRODUCT PLUSHER WDC 8 series instrument washer disinfectors are offered in single door formation with manual horizontal

More information

LCF Touch Modbus Datasheet Application Security Advice Caution

LCF Touch Modbus Datasheet Application Security Advice Caution LCF Touch Modbus Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 3.11.214 Application Modern design flush mounting fan coil room

More information

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS... 2 GENERAL... 2 INDOOR UNIT PART NAMES... 3 REMOTE CONTROL PART NAMES...

More information

Coffee Machine Zia series

Coffee Machine Zia series Coffee Machine CoEx Brewer - Freshbrew EN Picture: Filename: Zia-6000_9CND_UserManual_5DUCNP20a_EN_v01-02.docx Disclaimer Manufacturer: Although this user manual has been put together with the utmost care,

More information

LOGIC CONTROLLED DEKO 25 EASE OF USE

LOGIC CONTROLLED DEKO 25 EASE OF USE DEKO 25 Washer-disinfector WASHROOM SYSTEMS DEKO 25 The DEKO 25 has been designed to bring reliability, outstanding cleaning and disinfection performance and quality into one compact and economic washerdisinfector.

More information

Operator s Manual. IP-100 Immersion Probe Cooler

Operator s Manual. IP-100 Immersion Probe Cooler Operator s Manual IP-100 Immersion Probe Cooler 110-810 04.27.11 Table of Contents Introduction... 3 General Information... 3 General Safety Information... 3 Safety Recommendations... 4 Unpacking Your

More information

HOT WASHER MODEL NO: KING150

HOT WASHER MODEL NO: KING150 WARNING: Do not use the hot washer without reading this manual HOT WASHER MODEL NO: KING150 PART NO: 7320175 OPERATION & MAINTENANCE INSTRUCTIONS LS1215 INTRODUCTION Thank you for purchasing this CLARKE

More information

SCAN200E USER S MANUAL

SCAN200E USER S MANUAL SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We

More information

Operating manual. Wascator FOM71 CLS

Operating manual. Wascator FOM71 CLS Operating manual Wascator FOM71 CLS Operating manual in original language 438 9200-91/EN 2010.05.03 Register now And be able to join the Wascator FOM 71 CLS web site where you can find: General information

More information

Virtu 40 series. Coffee machine

Virtu 40 series. Coffee machine Virtu 40 series Coffee machine Users manual Model: Virtu 40 Machine type: 9FEC Revision B, English Reference: 5DUFEK20 Your supplier is: The manufacturer of the machine is: De Jong Duke Postbus 190 3360

More information

I.F.U Re/Processing Reusable Medical Devices

I.F.U Re/Processing Reusable Medical Devices I.F.U Re/Processing Reusable Medical Devices Distributed by: MANUFACTURER: GA 26-09-001 -EN /20130719 Contents 1 Overview of preparation methods... 3 2 Safety and responsibility... 4 3 Explanation of symbols...

More information

GMH 285 / GMH 285-BNC

GMH 285 / GMH 285-BNC GMH 285 GMH 285-BNC H69.0.01.6C-02 Operating Manual Pt1000 Precision Thermometer For exchangeable probes, with alarm as of version V1.0 GMH 285 / GMH 285-BNC GMH-GREISINGER GMH-GREISINGER WEEE-Reg.-Nr.

More information

AZTECA A LITRE STERILISER

AZTECA A LITRE STERILISER Product Description Azteca A-6615 is a fully automatic high-speed pre & post vacuum steam sterilizer. This model is an electrically heated sterilizer, which operates with saturated steam as a sterilizing

More information

USER MANUAL HD SERIES. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704 HD5.

USER MANUAL HD SERIES. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704 HD5. USER MANUAL SERIES 5 5 Square Read the instructions before using the machine. EN (Original Instruction) 9123930 / 1704 KEEP THIS USER MANUAL FOR FUTURE USE 2017 Fri-Jado BV, Etten-Leur, The Netherlands.

More information

DEKO 25 washer-disinfector

DEKO 25 washer-disinfector DEKO 25 washer-disinfector DEKO 25 The DEKO 25 has been designed to bring reliability, outstanding cleaning and disinfection performance and quality into one compact and economic washer-disinfector. It

More information

Coffee Machine Zia series

Coffee Machine Zia series Coffee Machine CoEx Brewer - Bean to Cup User Manual User Manual EN Picture: Zia 8.000 Serie Filename: Zia-8000_9CND_UserManual_5DUCNP20b_EN_v01-01.docx Disclaimer Manufacturer: Although this user manual

More information

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS PRODUCT PLUSHER WDS 12 series instrument washer disinfectors are offered with single or double door formation with manual

More information

MODEL 7000 SUCTION UNIT

MODEL 7000 SUCTION UNIT MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices

More information

FAVORIT34502VIO. EN User Manual

FAVORIT34502VIO. EN User Manual FAVORIT34502VIO EN User Manual 2 www.aeg.com CONTENTS 1. SAFETY INFORMATION...3 2. SAFETY INSTRUCTIONS... 4 3. PRODUCT DESCRIPTION... 6 4. CONTROL PANEL...6 5. PROGRAMMES... 7 6. SETTINGS... 8 7. BEFORE

More information

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL) Edition 8 From serial no. 106000- Publ. no 4869701-00 OM 5030NHD; 2012-02 Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL) English CONTENTS Safety...8 2 Operating instructions...9 3 Technical specifications...10

More information

Installation and operation manual

Installation and operation manual Installation and operation manual Drying cabinet FC 18 PODAB 2009 2 Contents Safety regulations 5 Specification 6 Dimensions 6 Technical information 6 Assembly instructions 7 Installation of the cabinet

More information

EHA Hoffmann International GmbH

EHA Hoffmann International GmbH EHA Hoffmann International GmbH User manual EHA-TRANSPRINT HP 2020 Machine-No.: Year: EHA Hoffmann International GmbH Michelsbergstraße 24 D-57080 Siegen/Germany Telephone: +49 271 39 32-0 Telefax: +49

More information

GETINGE WD14 TABLO A GOOD-LOOKING TABLETOP WASHER-DISINFECTOR. Always with you

GETINGE WD14 TABLO A GOOD-LOOKING TABLETOP WASHER-DISINFECTOR. Always with you GETINGE WD14 TABLO A GOOD-LOOKING TABLETOP WASHER-DISINFECTOR Always with you 2 GETINGE WD14 TABLO IT S ALL ABOUT TIME Small wards and clinics have big demands on being able to reuse instruments and circulation

More information

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. LUMINOUS INDICATORS AND COMMANDS... 9 6. DIP-SWITCH

More information

SimpleVIS Viscometer Reference Guide P

SimpleVIS Viscometer Reference Guide P SimpleVIS Viscometer Reference Guide P82.0090 Run Status Indicator Lamps Sample/Solvent Port Waste Bottle Dust Cover Temperature Calibration Port Touch Screen Display RS-232 Serial Port Exhaust Muffler

More information

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1 OPERATION MANUAL EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1 EKHVMRD50+80ABV1 EKHVMYD50+80ABV1 CONTENTS Page 1. Definitions... 1 2. Introduction... 2 2.1. General information... 2 2.2. Scope

More information

Monitored Pneumatic Valves On Series Ported Manifold

Monitored Pneumatic Valves On Series Ported Manifold Monitored Pneumatic Valves On Series Ported Manifold Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per EN 954-1 & AS4024.1 SIL 3 as per IEC 61508 Applications Include: Pneumatic Presses

More information

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS Page 1 of 10 THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS Purpose of Manual The purpose of this manual is to provide operating, servicing and repair instructions for the Summit standard models ThermaPhase

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

Packing. Euronda Spa t (+39) m euronda.com

Packing. Euronda Spa t (+39) m euronda.com Packing The purpose of the packing phase is to ensure that sterilized instruments will remain sterile for a certain amount of time, allowing a safe and hygienic storage. It involves putting instruments

More information

AQUARIUS 45 MARINE SERVICE MANUAL

AQUARIUS 45 MARINE SERVICE MANUAL AQUARIUS 45 MARINE SERVICE MANUAL CONTENTS: PAGE 1. INTRODUCTION 3 2. SAFETY INSTRUCTIONS 4 3. BASIC INSTRUCTIONS 5 3.1. Installation Details 5 3.2. Operating the Boiler for the First Time 6 3.3. Troubleshooting

More information

DEKO Washer-disinfector WASHROOM SYSTEMS

DEKO Washer-disinfector WASHROOM SYSTEMS DEKO 2000 Washer-disinfector WASHROOM SYSTEMS RELIABLE PERFORMANCE The DEKO 2000 is designed and constructed to meet the performance and design requirements stated in EN ISO 15883-1 Washer-disinfectors

More information

VS LD series vertical steam sterilizers

VS LD series vertical steam sterilizers VS LD series vertical steam sterilizers Steelco vertical Steam Sterilizers VS LD series are designed to answer the typical sterilization needs of a laboratory: glassware, stainless steel instruments, culture

More information

Diplomat Inverter/Diplomat Duo Inverter

Diplomat Inverter/Diplomat Duo Inverter www.thermia.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) Copyright Thermia Värmepumpar Table of

More information

Autofill Wall Mount Boilers

Autofill Wall Mount Boilers USER INSTRUCTION MANUAL Autofill Wall Mount Boilers HELPLINE 0844 372 7766 Redring Warranty 2 Year Parts 2 Year Labour 083329501-05/12/13 Contents 1.0 About your Product My Product (please complete this

More information

Trotec PAC FT 2600 Portable air conditioner

Trotec PAC FT 2600 Portable air conditioner Trotec PAC FT 2600 Portable air conditioner The PAC FT 2600 portable room air conditioner comes with an infrared remote control and an air outlet hose with a flat nozzle.the unit s primary function is

More information

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN) Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN) Ovens Service Manual Models OMFP6010 CONTENTS This document has been published to be used for service only. The contents

More information

Operator Guide. Publication No. OI /97-Eng. KODAK Automixer II Plus

Operator Guide. Publication No. OI /97-Eng. KODAK Automixer II Plus Operator Guide Publication No. OI 3439-1/97-Eng KODAK Automixer II Plus ii PLEASE NOTE The information contained herein is based on the experience and knowledge relating to the subject matter gained by

More information

Refrigerated Incubator Model and Operating Instructions

Refrigerated Incubator Model and Operating Instructions Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.

More information

SOLUSCOPE SERIES 3 DESIGNED WITH THE FUTURE IN MIND FEATURES FLEXIBLE ENDOSCOPE DISINFECTOR / STERILISER

SOLUSCOPE SERIES 3 DESIGNED WITH THE FUTURE IN MIND FEATURES FLEXIBLE ENDOSCOPE DISINFECTOR / STERILISER SOLUSCOPE SERIES 3 FLEXIBLE ENDOSCOPE DISINFECTOR / STERILISER FEATURES Sterile Cycle HLD Cycle Continuous Leak Test Channel Flow Monitoring Pre Disinfection Wash Cycle Fast Cycle Time Barcode Tracking

More information

INSTRUCTIONS CertoClav EL

INSTRUCTIONS CertoClav EL High Pressure-LABORATORY AUTOCLAVE Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization As an aid in research and development Thermometer Lid handle with locking

More information

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.: Glass and Dishwashers ECOMAX 402/452/502 (incl. Australian 452-90/502) INSTALLATION AND OPERATION INSTRUCTIONS (original instructions) Starting from Serial No.: 8663 4000 REV. 05.10.2015 EN IMPORTANT NOTES

More information

½ Monitored Pneumatic Valves On Series Ported Manifold

½ Monitored Pneumatic Valves On Series Ported Manifold ½ Monitored Pneumatic Valves On Series Ported Manifold Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per AS4024.1-Part 1502 & 1502 SIL 3 as per IEC 61508 & EN ISO 13849-1 Applications

More information

LCF Touch. Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet. Application. Security Advice Caution.

LCF Touch. Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet. Application. Security Advice Caution. LCF Touch Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 3.11.214 Application Modern design flush mounting fan coil room thermostat,

More information

USER INSTRUCTION MANUAL. Autofill Wall Mount Boilers /12/14

USER INSTRUCTION MANUAL. Autofill Wall Mount Boilers /12/14 USER INSTRUCTION MANUAL Autofill Wall Mount Boilers EN 083272701-11/12/14 Contents 1.0 About your Product My Product (please complete this section) page 3 Introduction page 4 Warranty page 4 Important

More information

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

Installation & operating manual. Swimming pool water. UV disinfection device UV10+ Installation & operating manual Swimming pool water UV10+ WARNING: UV-C radiation damages eyes and skin. Avoid direct radiation 2013 V2.5 www.vanremmen.nl Page 2 of 2 Contents 1. GENERAL... 4 2. WHAT IS

More information

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4 GB OPERATING MANUAL ORWAK 3400 March 2005 PUBL. NO 4869057-00 Edition 4 English TABLE OF CONTENTS Safety... 82 Operating instructions... 93 Technical specifications. 104 Dimensional drawing... 104 Transport...

More information

Coffee Machine Siro Touch 600 series

Coffee Machine Siro Touch 600 series Coffee Machine Siro Touch 600 series CoEx brewer - Freshbrew Picture: Filename: SiroTouch-600_9CND_UserManual_5DUCNH20b_EN_v01-01.docx Disclaimer Manufacturer: Although this user manual has been put together

More information

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website: Phone:

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website:    Phone: IR330 Inspection Rewinder with Label Dispenser & Inkjet IR330 Operation Manual Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website: www.gm.dk. E-Mail: gm@gm.dk. Phone: +45 4581

More information

Edition 1, From serial no Publ. no A OM B 900, Orwak Brickman 900. Operating instructions (in the original)

Edition 1, From serial no Publ. no A OM B 900, Orwak Brickman 900. Operating instructions (in the original) Edition 1, From serial no. 10901- Publ. no A922-90619 OM B 900, 2010-01 Orwak Brickman 900 Operating instructions (in the original) CONTENTS Safety... 2-3 Safety features... 3 Range of application... 3

More information

Focus 4010\ Focus 4010 HT porcelain firing furnace

Focus 4010\ Focus 4010 HT porcelain firing furnace INSTRUCTION MANUAL Focus 4010\ Focus 4010 HT porcelain firing furnace Warning You have available one of the most precise dental furnaces equipped with a heating muffle made by the original manufacturer

More information

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product. USER MANUAL Portable Air Conditioner and Heater With Heat Pump Technology PAC12 PAC15 PAC18 Please read this manual carefully prior to operating the product. TABLE OF CONTENTS INTRODUCTION... 3 IMPORTANT

More information

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro 2006/01 Content Important Information 1. Notes... 3 1.1 CE - Labeling... 3 1.2

More information

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A... 70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................

More information

½ Monitored Pneumatic Valve Patented Technology

½ Monitored Pneumatic Valve Patented Technology ½ Monitored Pneumatic Valve Patented Technology PBM4-S (Valve only air service equipment not included) SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per AS4024.1-Part 1502 & 1502 SIL 3 as per IEC 61508

More information

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual 008094 All fire extinguishers should be installed, inspected and maintained in accordance with

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com GfG Products for Increased Safety Congratulations

More information

Product Manual Glue Applicators MS 80 and MS 200

Product Manual Glue Applicators MS 80 and MS 200 Product Manual www.pakarte.com Glue Applicators MS 80 and MS 00 Translation from German to English Table of Contents Product Description General Safety Instructions Safety Measures to be taken during Operation

More information

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL) Edition 8, From serial no. 106000- Publ. no 4869699-00 OM 5030, 2012-02 Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL) English CONTENTS Safety...8 2 Operating instructions...9 3 Technical specifications...10

More information

User Manual WMF Cup&Cool WMF Cup

User Manual WMF Cup&Cool WMF Cup coffee wakes up the world User Manual WMF Cup&Cool WMF Cup Add-on Equipment English bistro! 2000S presto! 1400 prestolino! 1300 Model Series 9018 / 9019 Order Nr. 33 0916 1000 Edition 04.2010 General Information

More information

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use GB122 Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C For trade use Please read thoroughly before attemting to diagnose fault 7217 4900 (03/2010) GB/IE List of contents

More information

User s Guide ENGLISH. Other languages available on our website:

User s Guide ENGLISH. Other languages available on our website: User s Guide ENGLISH Other languages available on our website: www.gilson.com. 1 SAFETY SYMBOLS USED 3 2 INTENDED USE 3 This equipment generates, uses and can radiate radio frequency energy and, if not

More information

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use GB122 7210 1300-12/2002 GB(EN) For trade use Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C Please read thoroughly before attempting to diagnose fault List of contents

More information

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use. Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1 ENGLISH Intended Use The Welch Allyn Rigid Reusable & Single Use Sigmoidoscopes and Anoscopes are used to illuminate and

More information

User s Manual Warm N Cozy

User s Manual Warm N Cozy User s Manual Warm N Cozy Point A Technologies, Inc. 20957 Currier Road, Unit C, Walnut, CA 91789 U.S.A. TABLE OF CONTENTS Page 1. Safety Procedures and Precautions...3 2. Electrical Information......4

More information

Bedpan washer-disinfectors CT 100 Compact CT 100 Compact PERLAVO

Bedpan washer-disinfectors CT 100 Compact CT 100 Compact PERLAVO Bedpan washer-disinfectors CT 100 Compact CT 100 Compact PERLAVO Compact-format bedpan washer-disinfectors Hygiene power on only 0.5 m 2! multifunctional effective to A0 3000 compact Hygiene, efficiency,

More information

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)

More information

PRELUDE. User Manual. PA3500 Mattress Overlay System. Guarantees and Warranty. 1.1 General Information 1.2 Intended Use. 3.1 Unpacking 3.

PRELUDE. User Manual. PA3500 Mattress Overlay System. Guarantees and Warranty. 1.1 General Information 1.2 Intended Use. 3.1 Unpacking 3. 1. Introduction 4 1.1 General Information 1.2 Intended Use PRELUDE 2. Product Description 4 3. Installation 4 3.1 Unpacking 3.2 Setting Up PA3500 Mattress Overlay System 4. Operation 5 4.1 Function Description

More information

OPTISENS TUR 2000 Technical Datasheet

OPTISENS TUR 2000 Technical Datasheet OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light

More information

smardy - pure water Reverse osmosis system YR100-A 75 GPD

smardy - pure water Reverse osmosis system YR100-A 75 GPD smardy - pure water Reverse osmosis system YR100-A 75 GPD Instruction manual [EN] Please read this manual carefully before operating the device and subsequently keep the instruction manual safely and within

More information

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy. Installation manual detector and controller Code no. 20711062 Page 1/30 CONTENTS Controller... 2 Function of the Relays... 2 Gas Detectors... 2 Cabling... 4 Mechanical Installation of the gas detectors...

More information

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents Installation, Service & Operation Manual SoftH 2 O FLO Water Softener Table of Contents 1. Description & Equipment Adjustments p.2 2. Components, Features & Functions p.3 3. Valve User Interface p.4 4.

More information

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort USER MANUAL S203 Controller for three circuits - control for 2 heating circuits - 1 domestic hot water control Saving energy, creating comfort This user manual consists of two parts. Issues that are intended

More information

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG Dohse Aquaristik GmbH & Co. KG www.dupla.com Using instructiontion T-Control Pro Item no. 80696 Status: 03/2013 Dohse Aquaristik GmbH & Co. KG www.dohse-aquaristik.com Table of contents 1. Introduction.............................................

More information

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2 TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2 1. Product Overview 1.1 Display Large LCD display for measured values and status Time Alarm (will stay lit until Upper / Lower limit value (except for TN2) the

More information

Original instructions Sense7-series Non-contact coded safety switch

Original instructions Sense7-series Non-contact coded safety switch Original instructions Sense7-series Non-contact coded safety switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage Read and understand this document Please

More information

REGISTER YOUR PRODUCT. for warranty claims INSTALLATION PROOF. Please complete and return

REGISTER YOUR PRODUCT. for warranty claims INSTALLATION PROOF. Please complete and return REGISTER YOUR PRODUCT for warranty claims INSTALLATION PROOF Please complete and return Fax: 305 662 7479 E-mail: pwd@metasys.com Dealer Date For the dental office: Please confirm that your technician

More information

User Manual Washing Machine L FL

User Manual Washing Machine L FL EN User Manual Washing Machine L 62270 FL 2 www.aeg.com CONTENTS 1. SAFETY INFORMATION...3 2. SAFETY INSTRUCTIONS... 4 3. PRODUCT DESCRIPTION... 6 4. CONTROL PANEL...7 5. PROGRAMMES... 8 6. CONSUMPTION

More information