STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

Size: px
Start display at page:

Download "STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS"

Transcription

1 SUBMITTAL DATA (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS PROJECT: ENGINEER: CONTRACTOR: DISTRIBUTOR: SCHWANK MODEL #: FUEL: APPROVED BY: DATE: APPROVAL #: 1 Submittal

2 NOTICE: Schwank reserves the right to make changes to equipment and specifications without obligation or notification. This publication, or parts thereof, may not be reproduced in any form, without prior written consent from Schwank. Unauthorized use or distribution of this publication is strictly prohibited. Schwank Group 5285 Bradco Boulevard, Mississauga, Ontario, L4W 2A6 phone: (905) Fax: Schwank Group 2 Schwank Way Waynesboro, Georgia, USA Phone: (706) Fax: csr@schwankgroup.com 2 Submittal

3 Quantity On This Project TABLE 1: MODEL CONFIGURA- TIONS TOTAL HEATER LENGTH CAPACITY KJ (BTU/HOUR) 0 to 1,371 m (4,500 ft.) ABOVE SEA LEVEL TURBULATOR REQUIRED LENGTH NOT REQ D GAS PRESSURE & ELECTRICAL FLUE & AIR VENTS SHIPPING WEIGHT Kg (LBS.) ,234mm (69 8 ) ,288mm (60 0 ) 210,000 Kj (200,000 Btu/hr) LINE MINIMUM mbar NG (5" W.C. NG) mbar LP (11" W.C. LP) 147 Kg (324 Lbs) 128 Kg (282 Lbs) ,234mm (69 8 ) 147 Kg (324 Lbs) ,288mm (60 0 ) 18,288mm (60 0 ) 12,395mm (40 8 ) 184,712 Kj (175,000 Btu/hr) 162,750 Kj (155,000 Btu/hr) X X LINE MAXIMUM mbar NG or LP (14" W.C.) 1016 mm 4" 128 Kg (282 Lbs) 128 Kg (282 Lbs) 90 Kg (197 Lbs) ,395mm (40 8 ) 9,450mm (31 0 ) 136,500 Kj (130,000 Btu/hr) X MANIFOLD 8.71 mbar NG (3½" W.C. NG) 24.9 mbar LP (10" W.C. LP) 90 Kg (197 Lbs) 70 Kg (154 Lbs) X ,395mm (40 8 ) 9,450mm (31 0 ) 115,500 Kj (110,000 Btu/hr) 12.7 mm (½") GAS INLET 90 Kg (197 Lbs) 70 Kg (154 Lbs) ,500mm (21 4 ) 105,000 Kj (100,000 Btu/hr) (10 S/S) 50 Kg (111 Lbs) ,395mm (40 8 ) 9,450mm (31 0 ) 6,500mm (21 4 ) 84,000 Kj (80,000 Btu/hr) 9,450mm (31 0 ) 63,000 Kj 6,500mm (21 4 ) (60,000 Btu/Hr) ELECTRICAL 120V, 60 HZ 145 VA THERMOSTAT Factory ready for 24V or 120V thermostat 90 Kg (197 Lbs) 70 Kg (154 Lbs) 50 Kg (111 Lbs) 70 Kg (154 Lbs) 50 Kg (111 Lbs) ,500mm (21 4 ) 47,250 Kj 50 Kg (111 Lbs) ,556mm (11 8) (45,000 Btu/hr) 1524 mm (5 ) 31 Kg (68 Lbs) 3 Submittal

4 TOP VIEWS OF SYSTEMS 4 Submittal

5 COMPONENT QUANTITIES PER HEATER MODEL SWAGED TUBE(S): (10') ALUMATHERM w/ FLANGE (10') ALUMINIZED w/ FLANGE (10') ALUMINIZED STEEL (10') EMISSIVE COATED STEEL TUBE FOCUS SHIELD REFLECTOR 2947 mm (9 8 ) ALUMINIZED COUPLER ACCUSEAL TUBE CLAMP END PLATE HANGER WEBBED HANGER REFLECTOR STABILIZER TURBULATOR(S): 1524 mm (5 ) STAINLESS STEEL (10') ALUMINIZED STEEL (10') STAINLESS STEEL ALUMINIZED STEEL HEATER QUANTITY ON PROJECT CUT-AWAY BURNER VIEW OPTIONAL ACCESSORIES 90 DEGREE SWAGED ELBOW KIT JS-0508-JZ 1 elbow, 1 reflector cap, 2 webbed hangers, 1 coupler 180 DEGREE SWAGED ELBOW KIT 2 x JS-0508-JZ 2 x 90 degree elbow kits - 3 webbed hangers, 2 couplers QUANTITY ON THIS PROJECT FRESH AIR INTAKE WALL HOOD ROOF VENT TERMINAL 102 mm (4") ROOF VENT TERMINAL 152 mm (6") WALL VENT TERMINAL 102 mm (4") WALL VENT TERMINAL 152 mm (6") FLUE VENT TEE (102 mm x 102 mm x 152 mm) (4" x 4" x 6") COUPLING KIT FOR TEE TRU-TEMP THERMOSTAT JS-0532-VC JA-0530-XX JA-0531-XX JA-0528-XX JA-0529-XX JA-0514-XX JA-0516-SW JM-0150-XX THERMOSTAT 24 VOLT JS-0569-WR THERMOSTAT 120 VOLT JL-0772-XX 24V THERMOSTAT OPTION: 2 TO 7 HEATERS PER THERMOSTAT JM-0303-KT CANADA: TYPE 1 HOSE GAS CONNECTOR USA: FLEXIBLE GAS CONNECTOR 45,000 to 155,000 JL-0771-RC 175,000 & 200,000 JL-0771-RB 1/2 x 24 45,000 to 155,000 JL-0771-XX 3/4 x ,000 & 200,000 JL-0771-ZZ 5 Submittal

6 APPROVED MINIMUM CLEARANCES TO COMBUSTIBLES MODEL SUSPENDED AT AN ANGLE UP TO 45 DEGREES SUSPENDED HORIZONTALLY D E F G A B C D A E F B B G C 6 Submittal

7 TYPICAL HANGER & SUPPORT SPACING RECOMMENDATIONS 152 mm (6 ) 2947 mm (116 ) 2947 mm (116 ) The distance between the tube flange plate and the hanger s plate must be 64 mm (2.5 ) REFLECTOR STABILIZER ELBOW / WEBBED HANGER INSTALLATION JS-0508-JZ 1. Webbed Hanger 2. Reflector Cap 3. Webbed Hanger Flange UNDER Reflector 3 4. Webbed Hanger Flange to mount UNDER the next Reflector Elbow 6. Tube / Elbow Coupler 2 7 Submittal

8 COMPONENT DESCRIPTION IGNITION DIRECT SPARK MODULE -HONEYWELL COMBINATION GAS VALVE REFLECTORS HEATER TUBE(S) 47,000 to 162,750 Kj (45 to 155 MBTUH) HEATER TUBE(S) 184,700 & 210,000 Kj (175 & 200 MBTUH) HANGERS HONEYWELL 24 VOLT REFLECTORS EXTEND 25.4 mm (1") BELOW BOTTOM OF TUBE SURFACE REFLECTORS ARE CLOSED AT START AND END OF EACH STRAIGHT RUN OF TUBES BY MEANS OF END PLATE HANGERS THE FIRST SECTION IS 3040 mm (10') LONG, 102 mm (4") DIAMETER,.95 mm (16 GA.) ALUMINIZED STEEL SWAGED ONE END EACH ADDITIONAL SECTION IS 3040 mm (10') LONG, 102 mm (4") DIAMETER,.95 mm (16 GA.) HOT ROLLED STEEL WITH EMISSIVE COATING SWAGED ONE END THE FIRST SECTION IS 3040 mm (10') LONG, 102 mm (4") DIAMETER,.95 mm (16 GA.) ALUMATHERM SWAGED ONE END THE SECOND SECTION IS 3040 mm (10') LONG, 102 mm (4") DIAMETER,.95 mm (16 GA.) ALUMINIZED STEEL SWAGED ONE END EACH ADDITIONAL SECTION IS 3040 mm (10') LONG, 102 mm (4") DIAMETER,.95 mm (16 GA.) HOT ROLLED STEEL WITH EMISSIVE COATING SWAGED ONE END ONE WEBBED HANGER SUPPORTS EACH 3040 mm (10') OF TUBE, EXCEPT THE FIRST AND LAST TUBES WHICH UTILIZE ONE WEBBED HANGER AND ONE PLATE HANGER AT EACH END. -NATURAL GAS 8.17 mbar (3 ½" W.C.) AT MANIFOLD -PROPANE 24.9 mbar (10" W.C.) AT MANIFOLD COUPLING KIT ALUMINIZED STEEL COUPLER ELBOWS 90 DEGREE ELBOW 102 mm (4") DIAMETER,.95 mm (16 GA.) ALUMINIZED STEEL, 216 mm (8 ½") CENTRE RADIUS SWAGED ONE END 180 DEGREE ELBOW 102 mm (4") DIAMETER,.95 mm (16 GA.) ALUMINIZED STEEL, 216 mm (8 ½") CENTRE RADIUS (ASSEMBLY OF TWO 90 DEGREE ELBOW KITS) BURNER HOUSING BOTTOM FOLDS AWAY, PROVIDING ACCESS FROM TWO SIDES, END AND BOTTOM BURNER INCORPORATES EFFECTILE CERAMIC BURNER HEAD WITH MINIMUM OF 835 FLAME PORTS COMPLETE WITH OPERATION STATUS INDICATOR LIGHTS TRANSFORMER SAFETY SWITCHES STATUS INDICATOR LIGHTS COMBUSTION AIR THERMOSTAT OPTIONS TERMINAL BLOCK ELECTRICAL CORD 120/24VAC; 20VA TWO SEPARATE AIR PRESSURE SWITCHES SENSE ADEQUATE COMBUSTION AIR AND BLOCKED FLUE GREEN: CALL FOR HEAT; YELLOW: IGNITION TRIAL; RED: FLAME ESTABLISHED COMBUSTION AIR DUCTED DIRECTLY TO INTAKE OF BLOWER SCHWANK TRU-TEMP (24V) SET CK THERMOSTAT WITH RADIANT & AMBIENT SENSORS, AND AUTOMATIC UNOCCUPIED SETCK MODE 24V THERMOSTAT NOTE: MULTIPLE HEATERS PER 24V THERMOSTAT REQUIRE TRANSFORMER/ RELAY KIT JM-0303-KT LINE VOLTAGE THERMOSTAT ALL WIRING CONNECTIONS BY MEANS OF COMMON TERMINAL BLOCK; JUMPER: FOR 120V THERMOSTAT; REMOVE FOR 24V THERMOSTAT 1220 mm (4 ) LENGTH 16/3 ELECTRICAL SUPPLY CORD WITH 3 PIN GROUNDED PLUG 8 Submittal

SUBMITTAL DATA S100 & S100U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS. Page 1 PROJECT: ENGINEER: CONTRACTOR:

SUBMITTAL DATA S100 & S100U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS.  Page 1 PROJECT: ENGINEER: CONTRACTOR: SUBMITTAL DATA & U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS PROJECT: ENGINEER: CONTRACTOR: DISTRIBUTOR: SCHWANK MODEL #: FUEL: APPROVED BY: DATE: APPROVAL #: www.schwankgroup.com Page

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

INSTALLATION / OWNER S MANUAL SERIES BROODER LOW INTENSITY TUBE TYPE INFRA RED HEATERS

INSTALLATION / OWNER S MANUAL SERIES BROODER LOW INTENSITY TUBE TYPE INFRA RED HEATERS INSTALLATION / OWNER S MANUAL ATH & SERIES BROODER IA LOW INTENSITY TUBE TYPE INFRA RED HEATERS FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this

More information

INSTALLATION / OWNER S MANUAL

INSTALLATION / OWNER S MANUAL INSTALLATION / OWNER S MANUAL Member of the International Schwank Group, Companies in: Germany, Netherlands, France, United Kingdom, Austria, Belgium, United States and Canada. Licensees Worldwide. NOTICE:

More information

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters. 12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com P For either indoor or outdoor installation. Not for use in

More information

Parts List for Ener-Radiant XL Tube Heaters

Parts List for Ener-Radiant XL Tube Heaters Parts List for Ener-Radiant XL Tube Heaters ERXL-0 F09XL ERXL-0 NG / BRN & Cont Box 0 Front Flange F09XL ERXL-0 LP / BRN & Cont Box 009 Reflector End Cap F00XL Tube Set- 0' 099 Spring Clips 0 Tube H.E.

More information

CLEARANCES TO COMBUSTIBLES

CLEARANCES TO COMBUSTIBLES 12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com Engineering Submittal Data EZB series straight and U shape

More information

INSTALLATION / OWNER S MANUAL

INSTALLATION / OWNER S MANUAL ultraschwank Models: UHE & InfraSave Ultimate Models: EIH HIGH RADIANT OUTPUT LOW INTENSITY TUBE TYPE INFRA RED HEATER INSTALLATION / OWNER S MANUAL WARNING Improper installation, adjustment, alteration,

More information

INSTALLATION / OWNER S MANUAL SCHWANK GAS FIRED INFRA RED HEATERS supraschwank 40 primoschwank 40 SERIES HIGH EFFICIENCY COMBINED INTENSITY

INSTALLATION / OWNER S MANUAL SCHWANK GAS FIRED INFRA RED HEATERS supraschwank 40 primoschwank 40 SERIES HIGH EFFICIENCY COMBINED INTENSITY INSTALLATION / OWNER S MANUAL SCHWANK GAS FIRED INFRA RED HEATERS supraschwank 40 primoschwank 40 SERIES HIGH EFFICIENCY COMBINED INTENSITY FOR YOUR SAFETY: Do not store or use gasoline or other flammable

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS) This section is based

More information

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations. HVAC Guideline Specifications supraschwank Packaged Luminous Infrared Radiant Gas Heater Combined Intensity (produces both Low and High Intensity radiant output) Commercial/Industrial Applications Size

More information

INFRARED RADIANT HEATERS

INFRARED RADIANT HEATERS IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design

More information

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls TM SERIES Available with 40,000 to 200,000 BTU/Hr. inputs and tube lengths from 10 feet to 70 feet. Aircraft Hangars Auto Dealerships Farm Buildings Fire Stations Body Shops Car Washes Sports Facilities

More information

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP CATALOG 9-117.1 JUNE, 2003 TABLE OF CONTENTS Modine's TLP Series sets the industry standard for low intensity infrared heating performance

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS SECTION 15540 - FUEL - FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

Typical Mount Height. Combustion Chamber

Typical Mount Height. Combustion Chamber ! WARNING: This heater must be installed and serviced by trained gas installation and service personnel only! Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS LOW-INTENSITY INFRARED HEATING SYSTEMS Omega II Pre Engineered Packages Products by: COMBUSTION SUBMITTAL DATA PROJECT: Specifications for Omega II UNITARY P.E.P. SYSTEMS PART 1 - GENERAL It is the intent

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

iq1001, Gen II Submittal Data

iq1001, Gen II Submittal Data , Gen II Submittal Data Date: Project Name: Bid Date: Fuel Type: Natural Gas Propane Project #: City State Zip: Engineer: Contractor: Factory Option: intouchbms KEY FEATURES Multiple Stainless (316L) Heat

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

GARAGE / WORKSHOP INFRARED HEATERS

GARAGE / WORKSHOP INFRARED HEATERS GARAGE / WORKSHOP INFRARED HEATERS 22,000-25,000 BTU/HR Heater For: Garages / Workshops Barns / Utility Buildings / Storage Sheds Animal Pens / Stalls Loading Docks Building Construction Sites Doorways

More information

INSTALLATION / OWNER S MANUAL LUMINOUS GAS FIRED INFRA RED HEATERS

INSTALLATION / OWNER S MANUAL LUMINOUS GAS FIRED INFRA RED HEATERS INSTALLATION / OWNER S MANUAL ECOSCHWANK & ECOSCHWANK X-Series IL & IL X-Series LUMINOUS GAS FIRED INFRA RED HEATERS FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapours and liquids

More information

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features. iq751 Submittal Data Date: Bid Date: Project Name: Project #: City/St/ZIP: Engineer: Contractor: Fuel Type: Natural Gas Propane Factory Option: intouch-bms Key Features Multiple Stainless (316L) heat exchanger

More information

CATALOG: HVAC - Gas Space Unit Heating

CATALOG: HVAC - Gas Space Unit Heating CATALOG: HVAC - **Wolff Bros. Supply, Inc. reserves the right to substitute like products. Product information is subject to Manufacturer rolling changes and/or typographical errors. Wolff Bros. Supply,

More information

INFRARED RADIANT TUBE HEATER

INFRARED RADIANT TUBE HEATER INFRARED RADIANT TUBE HEATER LTS 40 250 SERIES PROJECT: ADDRESS: ARCHITECT/ENGINEER: ADDRESS: CONTRACTOR: ADDRESS: SUBMITTED BY: N-NATURAL GAS (CHECK ONE) L-PROPANE GAS EQUIPMENT USED: 5-SINGLE STAGE (CHECK

More information

Residential/Commercial Gas Condensing Tankless Models

Residential/Commercial Gas Condensing Tankless Models 15-Year Residential/1-Year Commercial Heat Exchanger Limited Warranty/5-Year Parts Warranty* FEATURES Ultra-Low NOx Condensing Technology Provides Unprecedented.95 Energy Factor Durable Heat Exchanger

More information

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES: TANKLESS CONDENSING HIGH EFFICIENCY COMMERCIAL GAS Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to 0.95 Uniform Energy Factor (UEF) which lowers operating costs and

More information

SECTION GAS-FIRED RADIANT HEATERS

SECTION GAS-FIRED RADIANT HEATERS SECTION 23 55 23 PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

RADIANT HEATER CATALOG

RADIANT HEATER CATALOG RADIANT HEATER CATALOG COMMERCIAL/INDUSTRIAL RADIANT HEATERS Heats Objects and People, Not the Air STYLES Low Intensity Tubular Radiant - Single-Stage - Two-Stage - Harsh Environment High Intensity Radiant

More information

INSTALLATION / OWNER S MANUAL

INSTALLATION / OWNER S MANUAL ecoschwank-x 36, 52 IL-X 150, 200 Gas-Fired Luminous (High Intensity) Infrared Heaters INSTALLATION / OWNER S MANUAL WARNING Improper installation, adjustment, alteration, service or maintenance can cause

More information

Cumberland Heating Systems

Cumberland Heating Systems Cumberland Heating Systems Cumberland "Radiant" Brooder Clean Burning...Fuel Efficient Maintaining proper in-house temperature is critical in climate control. A consistent, stressfree environment promotes

More information

STERLING RSS SERIES INFRARED RADIANT TUBE HEATER

STERLING RSS SERIES INFRARED RADIANT TUBE HEATER RSUS-1 RSS 40-200 SERIES (Check One) RSU 40-200 SERIES NATURAL GAS (Check One) PROPANE GAS STANDARD CONSTRUCTION ALC CONSTRUCTION (All Heat Treated Emitter Tubes) SINGLE STAGE TWO STAGE EQUIPMENT USED:

More information

INSTALLATION / OWNER S MANUAL

INSTALLATION / OWNER S MANUAL primoschwank & supraschwank HIGH EFFICIENCY COMBINED INTENSITY Gas-Fired Luminous (High Intensity) Infrared Heaters INSTALLATION / OWNER S MANUAL WARNING Improper installation, adjustment, alteration,

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

i200, Gen II i250, Gen II Submittal Data

i200, Gen II i250, Gen II Submittal Data i00, Gen II i50, Gen II Submittal Data Date: Project Name: Project #: Bid Date: Fuel Type: Natural Gas Propane Model Selection: i00 i50 City State Zip: Engineer: Contractor: KEY FEATURES Stainless (36L)

More information

iq251, Gen II Submittal Data

iq251, Gen II Submittal Data iq25, Gen II Submittal Data Date: Project Name: Bid Date: Fuel Type: Natural Gas Propane Project #: City State Zip: Engineer: Contractor: Factory Option: intouch-bms KEY FEATURES Stainless (36L) Heat Exchanger

More information

SUBMITTAL SCHEDULE & DATA

SUBMITTAL SCHEDULE & DATA SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model

More information

Min. Mount Height. Min. Mount Height. Length Weight

Min. Mount Height. Min. Mount Height. Length Weight *! ARNING: This heater must be installed and serviced by trained gas installation and service personnel only! Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

GAS-FIRED HIGH INTENSITY INFRARED HEATERS GAS-FIRED HIGH INTENSITY INFRARED HEATERS CATALOG 9-116.1 MARCH, 2003 TABLE OF CONTENTS Modine's MT Series is a gas-fired, high intensity ceramic infrared heater. Ideal for spot heating, the MT series

More information

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse TANKLESS HIGH EFFICIENCY CONDENSING WATER HEATERS COMMERCIAL-GRADE RESIDENTIAL / COMMERCIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to.95 Uniform Energy Factor

More information

A. Product Data: Include rated capacities, furnished specialties and accessories.

A. Product Data: Include rated capacities, furnished specialties and accessories. BASE BID: SECTION 15542 FUEL-FIRED RADIANT HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install a Co-Ray-Vac Low Intensity Vented Infrared Radiant Vacuum Gas Heating System. System must be certified

More information

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh GAS UNIT HEATERS / DUCT FURNACES LF24 COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ PRODUCT SPECIFICATIONS Bulletin 2008 July 206 Supersedes October 20 Steady-State Efficiency - up to 8% Input

More information

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION INSTALLATION AND OPERATING INSTRUCTIONS FOR THE HARDY Fuel Oil Furnace Models D-140 & D-350 HARDY MANUFACTURING COMPANY, INC. 12345 ROAD 505 PHILADELPHIA, MS 39350 PHONE: (601) 656-5866 FAX: (601) 656-4559

More information

Tankless Condensing High Efficiency Water Heaters

Tankless Condensing High Efficiency Water Heaters Tankless Residential Water Heater Series Tankless Condensing High Efficiency Water Heaters Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to an unprecedented.95 Uniform

More information

FG7T (C and L Series)

FG7T (C and L Series) TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The

More information

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters Heating Systems Brooders, Space Heaters and QuadRadiant Heaters Let s grow together. QUADRATHERM QuadRadiant Heater Patent Pending With Chore-Time s QUADRATHERM Heater, the Most Innovative Concept in Heating

More information

Insert Manual. RHT Series WARNING. For Your Safety

Insert Manual. RHT Series WARNING. For Your Safety RHT Series Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The RHT Series Infrared Tube Heater is a positive pressure,

More information

C1050ES Tankless Water Heater

C1050ES Tankless Water Heater Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A E F Hot water outlet Cold water inlet Inlet water filter

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-1500T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler Bosch Buderus SSB1000TL/TL2/TL3/TL4 Engineering Submittal Sheet Boiler Components C US Engineering Specifications There shall be provided and installed Bosch Buderus Model SSB1000TL in quantities of. Bosch

More information

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) ASSEMBLY INSTRUCTIONS - NXS SERIES OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED RADIANT

More information

Low-Intensity, Infrared Heating Systems Submittal: HE Series

Low-Intensity, Infrared Heating Systems Submittal: HE Series Low-Intensity, Infrared Heating Systems Submittal: HE Series Job: Location: Engineer: Gas Specs: Date: QTY. MODEL NO. HE UNIT INPUT BTU/HR QTY. MODEL NO. HE UNIT INPUT BTU/HR QTY. MODEL NO. HE UNIT INPUT

More information

Insert Manual. DET3 Series WARNING. For Your Safety

Insert Manual. DET3 Series WARNING. For Your Safety Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The Infra-Red Tube Heater is a positive pressure, two-stage radiant

More information

POWER VENTER. Model: PVE Series

POWER VENTER. Model: PVE Series POWER VENTER Model: PVE Series CONTENTS Typical Venting System Components... System Operation... Power Venter Sizing... Installation Safety Instructions... Installation of Power Venter... Connecting Power

More information

940ES Tankless Water Heater

940ES Tankless Water Heater Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A Hot water outlet Cold water inlet E F Front view Side

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing Mascot Gas-Fired Residential and Commercial Wall-Mounted Boiler Easy Installation, 96% Efficiency, Fully Condensing Mascot is a high-efficiency, wall-mounted boiler available in three BTU sizes 126, 167,

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

Power Direct Vent PDV(S&T) Models

Power Direct Vent PDV(S&T) Models COMMERCIAL REPLACEMENT PARTS LIST Power Direct Vent PDV(S&T) Models Includes Hydrojet Total Performance System Effective: January, 2012 ECO 7731 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING

More information

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY: INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS (CHECK ONE) PROPANE GAS PROJECT: ARCHITECT/ENGINEER: NAME: ADDRESS: NAME: ADDRESS: DATE: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: EQUIPMENT

More information

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F) UNIT HEATER CATALOG Form RZ-NA-C-UH (Version F) BACKGROUND Reznor was founded in 1888 to manufacture the Reznor reflector heater, which used a luminous flame gas burner developed by George Reznor. This

More information

The WCGH High Efficiency Commercial Water Heater with Storage Tank

The WCGH High Efficiency Commercial Water Heater with Storage Tank The WCGH High Efficiency Commercial Water Heater with Storage Tank Advanced hi-fin heat exchanger design for superior performance up to.92 UEF Many Commercial Applications w w w.htproducts.com SCAQMD Rule

More information

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler Stainless Steel Condensing Boiler Engineering Submittal Sheet Boiler Components Engineering Specifications There shall be provided and installed Bosch Buderus SSB255 SSB 399 SSB512 in quantities of. Bosch

More information

The Economical, Unitary Infrared Heater Submittal: BH Series

The Economical, Unitary Infrared Heater Submittal: BH Series Blackheat BH The Economical, Unitary Infrared Heater Submittal: BH Series Job: Location: Engineer: Gas Specs: Date: QTY. MODEL NO. BH UNIT INPUT BTU/HR QTY. MODEL NO. BH UNIT INPUT BTU/HR QTY. MODEL NO.

More information

Boiler & Water Heater

Boiler & Water Heater MIGHTY THERM2 Date: Project #: Pump-Mounted Boiler & Water Heater MT2H Hydronic Heater MT2V Volume Water Heater Indoor/Outdoor Sizes 500-2000 Submittal Engineer: Project Name: Prepared By: Location: Bid

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP, BTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.16 NOVEMBER,

More information

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil UNIT HEATER CATALOG COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS FUEL Natural Gas Propane Fuel Oil CAPACITIES 25-1,200 MBH 80% - 93% Thermal Efficiency 380-16,750 CFM AIR DELIVERY Propeller

More information

940ES Tankless Water Heater

940ES Tankless Water Heater Engineering Submittal Sheet Overview and Certifications LOW-LEAD U P C C US Massachusetts Plumbing Board Approved Engineering Specifications Water heater shall be a Model Therm 940 ES. Plant shall consist

More information

Infrared Heating Catalog

Infrared Heating Catalog INFRA-REZ HEATER Low-Intensity Infrared Model TRP - Packaged Tubular Radiant Heater Model TR - Modular Tubular Radiant Heater High-Intensity Infrared Model RIH/RIHV - Surface Combustion Radiant Heaters

More information

INFRARED RADIANT TUBE HEATER

INFRARED RADIANT TUBE HEATER INFRARED RADIANT TUBE HEATER LTU 40 250 SERIES PROJECT: ADDRESS: ARCHITECT/ENGINEER: ADDRESS: CONTRACTOR: ADDRESS: SUBMITTED BY: N-NATURAL GAS (CHECK ONE) L-PROPANE GAS EQUIPMENT USED: 5-SINGLE STAGE (CHECK

More information

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor PHNTM Floor Standing Heating s Phantom-X 399C/500C Residential High Efficiency Gas s PHNTM399C, PHNTM500C Submittal Sheet Wholesaler Job Name Mechanical Contractor Number Gas Type BTU/hr INPUT BTU/hr OUTPUT

More information

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler Bosch Buderus SSB800/1000/1000TL Engineering Submittal Sheet Boiler Components C US Engineering Specifications There shall be provided and installed Bosch Buderus Model SSB800 SA, Model SSB1000 SA, Model

More information

MASTERTEMP HEATER REPLACEMENT PARTS

MASTERTEMP HEATER REPLACEMENT PARTS 0 Section. Maintenance/Replacement Parts Electrical System (Key Nos. through 4), See Page 2 Burner System (Key Nos. through ), See Page 4 Water System (Key Nos. through ), see Page 2 Repair Parts are available

More information

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP COMMERCIAL-GRADE RESIDENTIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring an up to 0.95 Uniform Energy Factor (UEF)

More information

Date: Bid Date: Model: i200 i200p. Project Name: Project #: Location: Fuel Type: Natural Gas Propane. Engineer: Contractor: Key Features.

Date: Bid Date: Model: i200 i200p. Project Name: Project #: Location: Fuel Type: Natural Gas Propane. Engineer: Contractor: Key Features. i200/i250/i200p/i250p Submittal Data Date: Project Name: Bid Date: Model: i200 i200p Project #: i250 i250p Location: Engineer: Fuel Type: Natural Gas Propane Contractor: Key Features Stainless (316L) heat

More information

LAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters

LAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters LAARS MIGHTY THERM High Efficiency Boilers and Volume Water Heaters The Ideal Replacement Boiler % Thermal Efficiency Straight Forward, Easy to Use Controls - 000 MBH s Industry Leading Low NOx, ppm Indoor/Outdoor

More information

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

A. Section Common Motor Requirements for HVAC Equipment: Fan motors. SECTION 235533 - FUEL-FIRED UNIT HEATERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Gas fired unit heaters. B. Oil fired unit heaters. C. Tubular infrared heaters. 1.2 RELATED REQUIREMENTS A. Section 230513

More information

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual 342 N. Co. Rd. 400 East Valparaiso, IN 46383 888-432-8924 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. VF/VG700 Jumbo Construction

More information

RADIANT HEATER CATALOG

RADIANT HEATER CATALOG RADIANT HEATER CATALOG COMMERCIAL/INDUSTRIAL RADIANT HEATERS Heats Objects and People, Not the Air STYLES Low Intensity Tubular Radiant - Single-Stage - Two-Stage - Harsh Environment High Intensity Radiant

More information

G6RC Series TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS G6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency upfl

More information

Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS

Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS WARNINGS WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S

More information

C1210ES Tankless Water Heater

C1210ES Tankless Water Heater Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A E Hot water outlet Cold water inlet F H J C I K G Front

More information

PVE SERIES POWER VENTER SYSTEM MANUAL

PVE SERIES POWER VENTER SYSTEM MANUAL PVE SERIES POWER VENTER SYSTEM MANUAL Contents Page I. Typical Venting System Components 2 II. System Operation 3 III. Power Venter Sizing 3,4 IV. Installation Safety Instructions 5,6 V. Installation of

More information

Residential Gas Tankless Water Heater

Residential Gas Tankless Water Heater CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to a 0.95 Uniform Energy Factor (UEF) which lowers operating costs

More information

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Tankless Condensing High Efficiency Water Heaters with Built-In Pump Tankless Residential Water Heater Series Tankless Condensing High Efficiency Water Heaters with Built-In Pump Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to an unprecedented

More information

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP COMMERCIAL-GRADE RESIDENTIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring an up to 0.95 Uniform Energy Factor (UEF)

More information

Form C-IR (Version F) COMMERCIAL/INDUSTRIAL RADIANT HEATERS. Heats Objects and People, Not the Air

Form C-IR (Version F) COMMERCIAL/INDUSTRIAL RADIANT HEATERS. Heats Objects and People, Not the Air Page of RADIANT HEATER CATALOG COMMERCIAL/INDUSTRIAL RADIANT HEATERS Heats Objects People, Not the Air STYLES Low Intensity Tubular Radiant - Single-Stage - Two-Stage - Harsh Environment High Intensity

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart M1200 Product Line Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.1 AFUE Input 60,000-120,000

More information

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective Commercial Water Heater Replacement Parts Price List For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB Prices Effective October 2, 2006 This parts price catalog supercedes book number SCBPB00306 and all

More information

sportschwank HIGH EFFICIENCY INFRARED HEATER INSTALLATION / OWNER S MANUAL

sportschwank HIGH EFFICIENCY INFRARED HEATER INSTALLATION / OWNER S MANUAL sportschwank HIGH EFFICIENCY INFRARED HEATER INSTALLATION / OWNER S MANUAL INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE CONSUMER CONSUMER: RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE DANGER If you smell

More information

TOLL FREE HEATSTAR OVERHEAD & VENT FREE HEATERS

TOLL FREE HEATSTAR OVERHEAD & VENT FREE HEATERS Enerco Group Inc. SHIPPING ADDRESS MAILING ADDRESS NEW PRODUCTS 22801 Aurora Rd., Ste. 3 & 4 PO Box 6660 Bedford Heights, OH 44146 Cleveland, Ohio 44101 www.enerco.com TOLL FREE 1 866 447 2194 2017 HEATSTAR

More information

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA Navien America Inc. Specification Details for the Navien models: CR-210 CR-210A For Indoor Installation Only For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA,

More information

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists. gas-fired water boiler Manual Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters Sizes 30-125 carry an additional approval for use in residential garage/workshops under CSA International Requirement 10.96 - U.S.

More information

WM97+ Wall Mount Boiler

WM97+ Wall Mount Boiler WM97+ Wall Mount Boiler Questions & Answers Models 70, 110 & 155 INSTALLATION 1. Can the boiler be installed in a living area? Yes, the WM97+ is a wall mounted boiler. The sealed combustion and internal

More information