13
14
15
16
17 B E ROUTE DUCT BEHIND BOOKSHELF. GRILLE MOUNTED ON TOP OF BENCH. BOOK CASE WALL 12x8 8x5 I 8"Ø 7"Ø 125 CFM I D M FLOOR SIDE WALL VENT 6x5 160 CFM 6"Ø 6"Ø 8x10 J C G 1 Section M-1 NOT TO SCALE Project No : Design By : Drawn By : CD TMK K 75 CFM 6"x8" EXHAUST DUCT UP TO ROOF CAP ON ROOF RELIEF HOOD LIKE GREENHECK GRSR, SIZE 16. SUPPLY WITH SLOPE CURB. Date Description ISSUED FOR CONSTRUCTION NOTE: COMBUSTION AIR AND FLUE VENT BOTH 3" SCH 40 PVC 14x12 UP IN CHASE 14x10 I 160 CFM 12x14 12x14 10x10 12x10 5 M-1 18x10 FUR-1: 75 MBH, 120/60/1Ø OCP 15 AMPS FUR-2: 100 MBH, 120/60/1Ø OCP 15 AMPS 3 M-1 NOTE: COMBUSTION AIR AND FLUE VENT BOTH 3" SCH 40 PVC UP IN WALL. VENTS ON ROOF TO BE GOOSE NECK. ACC-1 FOR FUR-1 NOMINAL 3.5 TON 208/230/60/1Ø,LRA 112 MCA24, OCP 40 AMPS B K 75 CFM C 1x12" DUCT UP IN CHASE TO GRAVITY ROOF HOOD. LIKE GREENHECK GRSI SIZE 20. SUPPLY WITH SLOPE CURB. A L 3 M-1 H 2 L Section SPRING RELIEF DAMPER SET FOR 0.08 IN WC CEILING These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Engineer. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Engineer. H M-1 NOT TO SCALE I 10'-0" 14x8 160 CFM 10x8 ACC-2 FOR FUR-2 NOMINAL 6 TON 208/230/60/1Ø,LRA 112 MCA24, OCP 40 AMPS 1 M-1 COMBUSTION AIR AND FLUE VENTS ON ROOF TO BE GOOSE NECK FRESH AIR VENT 10x10 B A 8x8 I 245 CFM I 9"Ø 9"Ø 245 CFM 8x5 8x5 B B F F 3 Section M-1 NOT TO SCALE HVAC PLAN NOTES HVAC Plans for 936 North Temple Ave Indianapolis, IN NOTES: -PRICE GRILLES LBPH SERIES / TYPE C CONCEALED BRACKET, 750 BORDER. -ALL FLOOR GRILLES SHALL BE BROWN. ALL CEILING GRILLES SHALL BE WHITE. A 120 CFM 12"x6" CORE 27C, PENCIL PROOF, 30 DEFLECTION SUPPLY B 120 CFM 12"x5" CORE 25C, PENCIL PROOF, 30 DEFLECTION SUPPLY NORTH Basement HVAC Plan 1/ = 1'-0" OUTSIDE AIR 12"x1 2x8" OUTSIDE AIR NORTH 1st Floor HVAC Plan 1/ = 1'-0" C D E F G H 75 CFM 12"x3" CORE 27C, PENCIL PROOF SUPPLY 150 CFM 12"x5" CORE 27C, PENCIL PROOF SUPPLY 130 CFM 12"x5" CORE 27C, PENCIL PROOF SUPPLY 170 CFM 12"x6" CORE 25C, PENCIL PROOF SUPPLY 200 CFM 12"x6" CORE 27C, PENCIL PROOF SUPPLY LOUVER FACE RETURN GRILLE LIKE PRICE MODEL 70, 2x18", FLAT BORDER w/countersunk SCREW HOLES. HVAC Plans FLOOR JOIST 10"x8" SUPPLY AIR FLOOR JOIST I J K PRICE MODEL SCD 6" NECK SUPPLY CEILING MOUNTED EXHAUST FAN, LIKE PENN BARRY ZEPHYR JRZT, 75 CFM, 120/60/1Ø. SUPPLY WITH WALL CAP LIKE MODEL SL20. INLINE FAN LIKE PENN BARRY ZEPHYR Z81S (TDA) 120/60/1Ø 250 CFM 5 OUTSIDE AIR Typical Detail where Duct Detail 4 Runs in Joist Space M-1 3'x4' TYPE 1 EXHAUST ONLY GREASE HOOD, LIKE GREENHECK GH-E-W, M 18"x16" WELDED GREASE DUCT UP TO EF-1, 2000 CFM 0.25SP, LIKE M-1 NOT TO SCALE M-1 NOT TO SCALE L PRICE STEEL EGG CRATE GRILLE 3 GRID, BORDER STYLE F, 16"x18" RELIEF. GREENHECK CUBE 141HP-X, 1 3HP, 1210 RPM, 120/60/1Ø. SUPPLY WITH CURB FOR SLOPED ROOF TO MATCH ROOF SLOPE.
18 PERIMETER DRAINAGE 1 P " CW UP TO FROST FREE HOSE BIB IN JOIST SPACE 3 4 " HW & CW UP 3 4 " UP SEAL PENETRATION THROUGH BASEMENT FOUNDATION GENERAL NOTES A. DRYER VENT TO BE HARD DUCT UP TO BOOSTER FAN IN ATTIC. BOOSTER FAN TO BE LINE FANTECH BDF110 WITH PRESSURE SWITCH, 120/60/1Ø, 80W. B. WATER HEATER TO BE LIKE: RHEEM PRESTIGE RTGH-84DVLN, DISCHARGE MAXIMUM SET TO 120 F, 157,000 BTU INPUT. HARD DUCT FOR DRYER UP M C. CW AND HW LINES TO HAVE 1" INSULATION. AREA DRAIN IN WINDOW WELL. TIE INTO PERIMETER DRAIN. TYPICAL OF 2. 2" VENT UP 1 1 2" VENT UP 2" LV-1 WC-1 C.O. 2" SAN 3 4 " CW 3" 3" WASTE DOWN 1 2 " HW & CW UP 3" V UP GUY GRAY BOX IN V WALL WITH HOT 3" FLUE UP AND COLD WATER CONNECTIONS WITH SHUT OFF VALVES 3" 3 4 " HW & CW 3 4 " FLUE V NAT GAS Project No : Design By : Drawn By : Date CD TMK Description ISSUED FOR CONSTRUCTION C.O. C.O. 2" 3" 3" F.D. SEE SIGHT PLAN FOR CONTINUATION. 3 4 " HW & CW UP IN WALL 2" EXIT WALL ABOVE GRADE IN JOIST SPACE 3 4 " HW & CW 3 4 " CW F.D. 2" 1 Typical Dirt Leg for Gas Appliance P-1 NOT TO SCALE These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Engineer. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Engineer. 3" F.D. F.D. 3 4 " CW " NAT GAS UP TO FIREPLACE 3 4 " CW UP TO FROST FREE HOSE BIB IN JOIST SPACE 1 1 DOWN FROM METER UP TO METER EXIT WALL ABOVE GRADE IN JOIST SPACE 1 1 C.O. 1" HVAC Plans for 936 North Temple Ave Indianapolis, IN 1" C.O. 3'-0" BELOW FINISH GRADE NORTH Under Slab Plumbing Plan 1/ = 1'-0" NORTH Basement Plumbing Plan 1/ = 1'-0" Piping Plans P-1
19 FIXTURE NOTES FFHB 2" SAN DOWN WC-1: AMERICAN STANDARD, FLOOR MOUNT, TANK TYPE, 1.6gpf, 215AA.004 WITH SEAT SAN DOWN WC-1 WC-1 LV-1 LV-1 MSB-1 2" SAN DOWN DF 1 1 2" SAN DOWN SK " NAT GAS DRYER VENT 3" WASTE VENT 3" FLUE 1 BASEMENT FLOOR P-2 NOT TO SCALE GEOTEXILE FILTER FABRIC TO WRAP STONE BED 1'-2" 3" SCHEDULE 40 PERFORATED PVC 1 MINIMUM TOTAL DEPTH WASHED GRAVEL OR STONE PERIMETER PIPING DRAINAGE LV-1: AMERICAN STANDARD, WALL HUNG. SUPPLY WITH CARRIER. LIKE REGALYN 20"x18", ON CENTER, STRAINER DRAIN, TRAP. ADA REQUIRED INSULATED DRAIN. SLONA FAUCET, LIKE OPTIMA ETF-600, SENSOR. SUPPLY WITH TRANSFORMER, CONTROL MODULE, SOLENOID VALVE, AND THERMOSTATIC MIXING VALVE. DF: HI-LO BARRIER-FREE DRINKING FOUNTAIN LIKE HAWS MODEL: 1011, SUPPLY WITH MOUNTING PLATE MODEL AND SUPPORT FRAME MODEL MSB-1: 2x2x10" MOP SINK BASIN, IMPACT RESISTANT FIBERGLASS. LIKE MUSTEE MODEL 63M. SUPPLY WITH FAUCET, REINFORCING BAR AND PAIL HOOK, VACUUM BREAKER INTEGRAL STOPS. LIKE MODEL A, HOSE AND HOSE HOLDER, AND MOP HANGER. SK-1: DOUBLE BOWL STAINLESS STEEL TOP MOUNT SINK AND FAUCET KIT, LIKE ELKAY: DAYTON MODEL DSE233244DF. SUPPLY WITH STRAINER AND WASTE PIPE. SUMP: PUMP FT HEAD, 120/60/1Ø 1 2HP. 18x30 POLY-FOAM BASIN AND COVER, WITH CHECK VALVE. LIKE ZOELLER PACKAGE w/ HIGH WATER ALARM. EJECT: PUMP TO PASS 2" SOLID, FT HEAD, 4 10HP, 120/60/1Ø. 18x30 POLY-FOAM BASIN AND COVER, WITH CHECK VALVE. LIKE ZOELLER PACKAGE w/ HIGH WATER ALARM. SK1: DOUBLE BOWL STAINLESS STEEL ADA COMPLIANT 22"W, 6"H,14 3 x16 3 LIKE ELKAY ECTSRAD33226BG. SUPPLY WITH OPEN GRID STRAINERS AND TAIL PIECE. FAUCET SINGLE HOLE WITH PULL OUT SPRAY LIKE ELKAY LK5000LS. DISPOSAL LIKE INSINKERATOR MODEL BADGER 1 2HP, SWITCH BUTTON. Project No : Design By : Drawn By : Date CD TMK Description ISSUED FOR CONSTRUCTION These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Engineer. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Engineer. FFHB: FROST FREE HOSE BIB WITH LOCKABLE COVER. TO 3" V.T.R. 3" V 2 1 2" V 1 1 2" V TO KITCHEN TO 1ST FLOOR RESTROOMS LV-1 2" V GUY GRAY BOX 2" 2" CO NAT GAS LINE UP FROM BASEMENT CO 3" WC-1 2" FFHB 3 4 " DOWN NATURAL GAS METER VALVE IN RISER 2 3" FD FD EJECT Basement Sanitary Riser Diagram P-2 NOT TO SCALE 3" V.T.R. 3" V 2" V 3 P-2 NOT TO SCALE WH WS Water Heater Piping Detail 3" V.T.R. 2" V HVAC Plans for 936 North Temple Ave Indianapolis, IN 3" V 2" V WC-1 2" V SK-1 WC-1 CO LV-1 LV-1 3" MSB-1 NORTH 1st Floor Plumbing Plan 1/ = 1'-0" EWC 3" Piping Plans and Details TO EJECTOR 4 1st Floor Sanitary Riser Diagram P-2 NOT TO SCALE P-2
20
21
SHOE PALACE HUNTINGTON PARK M.200
M.200 SPLIT SYSTEM CONDENSING UNIT SCHEDULE MARK SERVICE MODEL NO. COOLING DIMENSIONS ELECTRICAL REMARKS CAPACITY AMBIENT DB REFRIGERANT LENGTH WIDTH HEIGHT WEIGHT VOLT/PHASE MCA MOP (MBH) (DEG F) (IN)
More informationGRILLE, REGISTER AND DIFFUSER SCHEDULE
ROOFTOP UNIT SCHEDULE (NATURAL GAS HEAT) MARK MANUFACTURER MODEL SUPPLY FAN COOLING COIL HEAT EXCHANGER MIN. MIN. MCA MOCP V/PH WEIGHT NOTES FAN CFM MIN ESP REFR. TH SH EAT LAT MIN. OUTPUT MIN. EFF. NOM.
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards
Date Description of Change Pages / Sections Modified ID 8/5/17 Entire document - mgl PART 1 - INTRODUCTION 1.1 This section applies to Plumbing for campus institutional facilities. A. Purpose: Yale University
More informationDESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.
PART 1 - GENERAL 1.1 Toilet rooms and utility rooms to have floor drains at lowest point. 1.2 Utilize Exposed Flushometers. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.
More informationHWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.
ELECTRIC WATER HEATER SCHEDULE DESIGNATION MODEL MANUFACTURER STORAGE RECOVERY TEMPERATURE LEAVING ELECTRICAL CHARACTERISTICS REMARKS/SPECIAL INSTRUCTIONS NUMBER GALLONS RATE RISE WATER K.W. VOLTAGE PHASE
More informationLAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.
ELECTRIC WATER HEATER SCHEDULE DESIGNATION MODEL MANUFACTURER STORAGE RECOVERY TEMPERATURE LEAVING ELECTRICAL CHARACTERISTICS REMARKS/SPECIAL INSTRUCTIONS NUMBER GALLONS RATE RISE WATER K.W. VOLTAGE PHASE
More informationUniversity of Rochester October 17, 2008 Brooks Landing Business Center
SECTION 224200 COMMERCIAL PLUMBING FIXTURES PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, equipment and services to perform operations required for the complete installation and related
More informationDESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.
PART 1 - GENERAL 1.01 Toilet rooms and utility rooms to have floor drains at lowest point. 1.02 Utilize Exposed Flushometers. 1.03 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.
More information900 N. Via Piemonte Ontario, CA
2 3 L 8 5'-0" 6'-1" 5'-0" 4'-0" 2'-0" D.5 6" 9'-9" K 2 1 2 " 5'-0" 2'-0" 1'-2" 8" 4 4.3 7'-0" C.6 1'-8 1 2 " 7'-0" 8" 10'-6" 5'-0" 8" 6" 6'-6" 6'-3" PLUMBING SCOPE OF WORK - DRAINS 7'-3" 6'-8" KEC TO PROVIDE:
More informationHVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION
GENERAL NOTES SPECIFICATIONS LEGEND SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. ABBREVIATIONS PLUMBING LEGEND SYMBOL DESCRIPTION ABB. SYMBOL DESCRIPTION ABB. SYMBOL
More informationJAMES P. KISSANE, ARCHITECT
UNISEX RESTROOM 6" X 9" UNISEX H.C. RESTROOM SIGN; BLUE NOTE: THE FASTENING HARDWARE FOR THE WALL BRACKETS FOR THE AND THE URINAL AND GRAB BARS MUST BE ABLE TO SUPPORT A 300 LB. WEIGHT. CONTRACTOR IS REQUIRED
More informationDUKE UNIVERSITY CONSTRUCTION STANDARDS
1 22 40 00 Plumbing Fixtures 1. General A. Definitions 1. Section includes a. Water closets and urinals b. Lavatories, sinks, and service sinks c. Electric water coolers, drinking fountains, d. Showers
More informationSECTION PLUMBING
SECTION 22 10 00 PLUMBING PART 1 GENERAL 1.1 WORK INCLUDED A. Furnish all labor, material and equipment necessary for the complete installation of the sanitary sewer system (including soil and vent piping),
More informationEXHAUST FAN SCHEDULE
DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR
More informationFRESH FROM THE KITCHEN FRESH FROM THE KITCHEN
PLUMBING SCOPE OF WORK - DRAINS KEC TO PROVIDE: - ALL TWIST WASTE VALVES & BASKET DRAINS, AS REFLECTED ON EQUIPMENT SCHEDULE, - PIPE CONDENSATE DRAIN FOR WALK IN COOLER WITH 3/4" COPPER TUBING, WITH NECESSARY
More informationMechanical/Plumbing Specification
Mechanical/Plumbing Specification Contents WC-1 Toilet 3 WC-1 Fixtures - Toilet Seat & Toilet Supply 4 UR-1 Urinal 5 UR-1 Fixtures - Metering Valve & Vacuum Breaker 7 - Wall Cleanout & Urinal Carrier 9
More informationMechanical System Description
1. Building Description: Mechanical System Description The building is a Type-1B construction, 9-levels, non-high rise building with 67 affordable family housing units. The first level of the structure
More informationDRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS
DRAWING SCHEDULE NUMBER TITLE M0-1 MECHANICAL NOTES AND LEGEND M1-0 MECHANICAL FLOOR PLAN M4-0 MECHANICAL SCHEDULES M4-1 MECHANICAL LOAD CALCULATIONS M5-0 MECHANICAL DETAILS M8-0 TCS BASYS CONTROLS DRAWINGS
More informationPLAN REVIEW SUBMITTAL GUIDE
PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide
More informationGENERAL PLUMBING REQUIREMENTS
22 00 00 GENERAL PLUMBING REQUIRMENTS i. 00 00 07 Design Professional Design Process Requirements ii. 00 00 08 Design Professional Documentation Requirements and Deliverables iii. 01 81 00 Facility Performance
More informationTHE HEMLOCK 3 BD 2.5 BA 1371 sq ft
THE HEMLOCK 3 BD 2.5 BA 1371 sq ft Level 1 Level 2 THE GEYSER 3 BD 2.5 BA 1561 sq ft Level 1 Level 2 THE ALGONQUIN 3 BD 1.5 BA 1524 sq ft WBDO77988 Level 1 Level 2 BUILDING PROCESS The best feature we
More informationA. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE
SCHEDULE OF S Penalty Fees. The fee for construction work performed before securing permit(s), where required, may be charged a fee of TWO TIMES THE COST OF THE PERMIT (S). Building Fee Schedule Residential
More informationCHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES
CHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES Where to Install Pipe Temperature Sensors for Freeze Protection 1 WHICH PIPES SHOULD I MONITOR FOR FREEZE
More informationJoseph Brennemann Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationFood Service Plan Review Information
Food Service Plan Review Information New or remodeled food preparation facilities, and those changing ownership, must undergo a plan review process prior to a health permit being issued. The purpose of
More informationProject General Notes DESCRIPTION ABBREVIATIONS AIR CONDITIONER ABOVE FINISHED FLOOR BALANCING DAMPER
G T D-X 000/000 DOMESTIC COLD WATER PIPE DOMESTIC HOT WATER PIPE DOMESTIC HOT WATER RETURN PIPE NATURAL GAS PIPE SANITARY VENT PIPE SANITARY PIPE DUCT SMOKE DETECTOR RELAY COIL THERMOSTAT TEMPERATURE SENSOR
More informationSECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:
SECTION 15440 PART I - GENERAL 1.01 WORK INCLUDED A. Types of plumbing fixtures required for the project include the following: 1. Water Closets 2. Urinals 3. Lavatories 4. Mop Sink 5. Sinks 6. Electric
More informationStructural Guidelines. Food Service Establishments. Retail Food Stores
Structural Guidelines for Food Service Establishments and Retail Food Stores Jefferson County Department of Health Food & Lodging Protection Division 1 Before construction or remodeling of a food service
More informationDOMESTIC WATER PACKAGED BOOSTER PUMPS
DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 150 foot
More informationDESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.
PART 1 - GENERAL 1.01 Toilet rooms and utility rooms to have floor drains at lowest point. 1.02 Utilize Exposed Flushometers. 1.03 Utilize wall hung toilet room fixtures. Urinals for handicapped may be
More informationGenevieve Melody Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationCMHC HOME MAINTENANCE CHECKLIST
Make sure air vents indoors and outdoors (intake, exhaust and forced air) are not blocked by snow or debris. Check and clean range hood filters on a monthly basis. Test ground fault circuit interrupter(s)
More informationA. Section Joint Sealants: Seal fixtures to walls and floors.
SECTION 224000 - PLUMBING FIXTURES PART 1 GENERAL 1.1 SECTION INCLUDES A. Water closets. B. Urinals. C. Lavatories. D. Sinks. E. Service sinks. F. Showers. G. Wash fountains. H. Eye wash fountains. 1.2
More informationJosefa Ortiz De Dominguez Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationDeCA DESIGN CRITERIA HANDBOOK PLUMBING SYSTEMS
GENERAL 1.01 Summary A. The plumbing system shall include sanitary drainage, waste, and vent piping; roof drains and interior downspouts; domestic cold water, hot water, and hot water recirculating piping;
More informationCharles W Earle Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationAgustin Lara Elementary Academy
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationC O D E S & A M M E N D M E N T S
SEVIER COUNTY UTILITY DISTRICT SEPTEMBER 2, 2014 Sevier County Utility District has adopted the 2009 International Fuel Gas Code for gas inspections. The following pages contain frequently used codes and
More informationHome Set-up and Maintenance. Maintenance
Home Set-up and Maintenance Home Set-up and Maintenance When moving into a resale home, there are some things that you will want to take care of. This list focuses on things related to the house, rather
More informationICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.
ICP Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A 1 inch diameter faucet, where the inside edge of the spout opening is 2.5 inches away
More informationCalmeca Academy of Fine Arts and Dual Language
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationRichard Henry Lee Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationR7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low
More informationGENERAL PLUMBING REQUIREMENTS
22 00 00 GENERAL PLUMBING REQUIRMENTS 1. GENERAL A. Related sections: i. 00 00 07 Design Professional Design Process Requirements ii. 00 00 08 Design Professional Documentation Requirements and Deliverables
More informationBUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS
BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used by
More informationArchitectural Alliance Incorporated MDP CONSULTING ENGINEERS, INC N 11th Street Beaumont, TX 77702
04/08/2013 last saved: TRENT plotted: DRAWN BY: TLH CHECKED BY: DWD 04/08/2013 last saved: DMCPHERSON plotted: DRAWN BY: TLH CHECKED BY: DWD 04/08/2013 last saved: DMCPHERSON plotted: DRAWN BY: TLH CHECKED
More informationEdward Jenner Elementary Academy of the Arts
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationINSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)
INSTALLATION MANUAL Manufactured by AQUA-AIR MANUFACTURING 542 W. 47 Confluence East 800 South, Ave., Salt Ivins, Lake Utah City, 84738 Utah 84123 (801) 265-9699 or (800) 916-5777 FAX (801) 268-3856 (435)
More informationElectrical Information
Electrical Information Breaker Panel 1: Service Type: Unreadable Panel Type: Unreadable Panel Number: Unreadable Manufacturer: Unreadable Amps: Unreadable Location: Storage Room Notes: Exterior Disconnect
More informationPLUMBING INSTALLATIONS
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT PLUMBING INSTALLATIONS A homeowner guide to plumbing requirements for single-family dwellings November 2017 contents Permit Requirements... 3 Inspection Requirements...
More information2015 MECHANICAL CODE REQUIREMENTS
2015 MECHANICAL CODE REQUIREMENTS ANTRIM COUNTY BUILDING DEPARTMENT PO BOX 188 205 CAYUGA STREET BELLAIRE, MI 49615 (231) 533-8373 FAX (231) 533-6041 Mechanical requirements for residential buildings per
More information2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures
PART 1: GENERAL A. This Section provides design standards for plumbing fixtures and trim. Certification of compliance with specified ANSI, UL, and ASHRAE Standards will be required, as appropriate, for
More informationHome Maintenance Schedule
Home Maintenance Schedule Regular Maintenance is the Key Inspecting your home on a regular basis and following good maintenance practices are the best way to protect your investment in your home. Whether
More informationTighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance
Groton Heights School Mechanical Evaluation TO: FROM: Amy Vaillancourt, Project Manager Harley Langford, Project Manger Jason Curtis, P.E. DATE: February 24, 2016; Revised May 31, 2016 On Monday, December
More informationWhile most maintenance is seasonal, there are some things you should do on a frequent basis year-round:
Inspecting your home on a regular basis and following good maintenance practices are the best way to protect your investment in your home. Whether you take care of a few tasks at a time or several all
More informationGENERAL PLUMBING NOTES
GENERAL SYMBOLS GENERAL PLUMBING NOTES PLUMBING LEGEND ABBREVIATIONS N PLAN OR DETAIL NO SHEET NUMBER KEYED NOTE TO PLAN REVISION NUMBER NORTH ARROW. IN THE PREPARATION OF THESE PLANS, THE ENGINEER HAS
More informationMechanical Appliance and Equipment Inspection Checklist
34 2015 IRC Performing Residential Mechanical s Mechanical Appliance and Equipment Checklist Inspect Mechanical Appliance and Equipment Comments / I. Identify possible mechanical appliance and equipment
More informationConvectors Steam / Hot Water November, 2009
Convectors Steam / Hot Water 13-111.3 November, 2009 TABLE OF CONTENTS I. Model Nomenclature...3 II. Design Benefits... 4-5 III. Typical Piping Arrangements....6 IV. Correction Factors A. Steam...7 B.
More informationMechanical Inspection Plumbing
0811 Fixtures Sinks, drinking fountains, water closets, showers, etc. Classroom Sinks. Classroom sinks (19) are enameled cast iron self rimming side ledge with gooseneck faucet trim with index handles,
More informationPh: (907) Quality Homes
Standard Specifications BUILDING your dream home www.destinyhomesak.com Ph: (907) 232-9751 Email: destiny4paul@aol.com Quality Homes 2016 1 HOME PRICE Prices of the homes are based on the $40,000 lot allowance.
More informationGARCIA GALUSKA DESOUSA Consulting Engineers
L#58619/Page 1/November 1, 2017 PLUMBING Executive Summary: Presently, the Plumbing Systems serving the building are cold water, hot water, sanitary, waste and vent system, storm drain piping, and natural
More informationJohn Palmer Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationTEMPOMIX COMFORT WATER SAVINGS VANDAL-RESISTANT SAFETY. Time flow basin mixer
367 COMFORT WATER SAVINGS VANDAL-RESISTANT SAFETY TEMPOMIX Time flow basin mixer Soft-touch operation Time flow 7 seconds Flow rate 3 lpm Solid brass body and reinforced fixings Maximum temperature limiter
More informationPERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18
NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section
More informationHVAC Equipment Access Equipment Location
City of Lancaster- Building Department 121 East Chestnut Street, Suite 102, Lancaster, Ohio 43130-3825 (740) 687-6649, Fax (740) 681-5030 Web site: www.ci.lancaster.oh.us/dept/building HVAC Heating, Ventilating,
More informationAmerica s Best Home Products, L.C. 855-GF14FAN. CoolMyGarage.com
Garage Complete Packages, Garage Ventilation Fans, Garage Flooring, Garage Door Insulation, Garage Overhead Storage, Garage Storage Cabinets, Garage Vacuums, Garage & Patio Heaters, Large Shop or Commercial
More informationPROPOSED NEW BUILDING
HYDRAULIC DRAWINGS MATERIALS SERVICES TO BE CONSTRUCTED FROM MATERIAL AS LISTED BELOW UNLESS NOTED OTHER WISE SHOWN ON DRAWINGS. SERVICE MATERIAL REMARKS SEWER DRAINAGE upvc SOLVENT WELDED JOINTS SEWER
More informationSidney Sawyer Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationSECTION DUCTWORK
PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on
More informationDOCUMENT TABLE OF CONTENTS
DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026
More informationSpecial Requirements For Health Care Facilities
Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements
More informationDESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES
2.05 PLUMBING GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.05 It is expected that the plumbing design professional will conform to accepted good engineering design practices.
More informationThe following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on
HOME PROPERTY SCAN INSPECTIONS The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on January 11, 2010 and
More informationCF SERIES CF100 CF200 CF300
CF SERIES CF100 CF200 CF300 EMBALMING SINKS WALL MOUNTS W/OPTIONAL LEG SUPPORTS REFERENCE / USER MANUAL Rev 6-10-14 IMPORTANT INFORMATION MODEL NO.: SERIAL NO.: DATE OF PURCHASE: DATE OF INSTALLATION:
More informationUNIVERSITY OF MISSOURI Central Station Air-Handling Units March
GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,
More informationHome Inspection Report
Pfeifer Home Inpsection, LLC 8332 Crystal Pointe Lane Indianapolis, Indiana 46236 317-340-1734 Lic #HI01700103 Home Inspection Report Columbus, IN 47201 Page 1 of 20 Table of Contents Definitions 2 General
More informationCanadian Property Inspections
Cover Page Canadian Property Inspections Home Inspection Report L9Z-1K4 Inspection prepared for: K.C. Pitman Date of Inspection: 3/6/2017 Time: 3pm Age of Home: 42 Size: 500-1000 Weather: Cloudy, cool.
More informationExtra Mile Inspection, Inc.
Cover Page Property Inspection Report Inspection prepared for: Jerry and Lynne Richardson Real Estate Agent: Polly Richardson - BHKR Lake Forest Date of Inspection: 3/13/2017 Time: 12 pm Age of Home: built
More informationMUKWONAGO AREA SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY
ARCHITECTURE ROLLING HILLS ELEMENTARY SCHOOL Rolling Hills Elementary was built in 1999 and is the newest addition to the Mukwonago Area School District. The building contains approximately 64,900 gross
More information1 Exam Prep Plumbing State Contractors Practice Exam 2
1 Exam Prep Plumbing State Contractors Practice Exam 2 1 According to Chapter 64E-6, when sizing a grease interceptor used in a restaurant, the correct formula is. A. (S) x (EW 12) x (LF) B. (S) x (GS)
More informationAmerica s Best Home Products, L.C. 855-GF14FAN. CoolMyGarage.com
Garage Complete Packages, Garage Ventilation Fans, Garage Flooring, Garage Door Insulation, Garage Overhead Storage, Garage Storage Cabinets, Garage Vacuums, Garage & Patio Heaters, Large Shop or Commercial
More informationModels. Options. Standard Features. LoH 2 O
LoH O Models LoH O Standard Features Uses 8 gallons (9. liters) of water per hour with sanitizing hot water rinse All tanks and hoods constructed from durable stainless steel with a No. finish and heliarced
More informationParadise Marketplace REAR FRONT. Unit # AOH +/- 1,700 SF +/- 20' +/- 85' +/- 85' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width. Depth
Electrical Information Breaker Panel 1: Service Type: 120/208 Panel Type: Type 1 Panel Number: 383-21 Manufacturer: Challenger Amps: 200 Location: Near Exit Door of Main Space Notes: Breaker Panel 2: Service
More informationFrancis M McKay Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationWashington Irving Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationOscar DePriest Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationWALL MOUNTED SHOWER SYSTEMS
Mixing Safety & Performance for Over 100 Years WALL MOUNTED SHOWER SYSTEMS Made in the USA with Domestic and Imported Parts 1360 Elmwood Ave., Cranston, RI 02910 TF: 800.222.1208 P: 401.461.1200 F: 401.941.5310
More information2016 Plumbing Supplemental Plan Review List
Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for
More informationCOMMERCIAL PERMIT APPLICATION AND CHECKLIST. Depending on the scope of your project, the following submittal requirements will apply:
Planning/Building Department 115 Ramsdell Street Fircrest WA 98466 (253) 564-8902 COMMERCIAL PERMIT APPLICATION AND CHECKLIST Depending on the scope of your project, the following submittal requirements
More informationUnit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information
Lease Outline Drawing Lakeland Retail Center 4000 US Hwy. 98, Unit HH Gregg, Lakeland, FL 33809 ±26' ±200' Lease Line Unit HH Gregg ±46' Lease Line ±21' Unit HH Gregg ±145' Lease Line ± 30,000 SF Width
More informationSH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT
SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will
More informationD. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.
SECTION 23 37 00 - AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Diffusers. 2. Registers 3. Grilles. PART 2 - PRODUCTS 2.1 ROUND CEILING DIFFUSERS B. Product Description:
More informationRTU 02 S x14. 16x16. 18x20 RTU x20. 10x14 S-1. MAU 01 12x12
YMBOL & ABBREV. T D Ø DL UC M E ME A/UP RA/RET EA/EH CD/R RR/RG ER/EG FC MVD FD (L) FLE T-TAT T-TAT D DIA. DL UC UPPLY AIR (RIE/DROP) RETURN AIR DUCT (RIE/DROP) EHAUT AIR DUCT (RIE/DROP) CEILING DIFFUER/UPPLY
More informationSECTION DOMESTIC WATER PIPING SPECIALTIES
SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationJFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine
JFT Flight Machine Models JFT Flight Machine Options Project Item Quantity CSI Section 00 Approval Date Blower dryer Additional wash section Additional load module Additional unload module (8m) wash down
More informationAn Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010
An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010 Putnam County Planning & Development Services Building & Zoning Division Compliance Section PO Box 1486 Palatka, FL 32178 1486 Office
More informationUnit # 1038 ± 900 SF Width ± 15' Depth ± 60'
±60' Lease Line Lease Outline Drawing Needles Towne Center 1004 E. Broadway St.,, Needles, CA 92363 ± 900 SF Width ± 15' Depth ± 60' Plans produced by: ID Plans 6/16/2017 (813) 657-2545 C 2017 Site map
More informationResidential New Home Construction Checklist
Residential New Home Construction Checklist A separate permit is required for each address. Address/PID: All materials and the installation of all materials must comply with the Minnesota State Building
More informationUnit # H ± 2,000 SF Width ± 25' Depth ± 80'
±80' Lease Line Lease Outline Drawing Sunnymead Plaza 24907 Sunnymead Blvd., Unit # H, Moreno Valley, CA 92553 Unit # H ± 2,000 SF Width ± 25' Depth ± 80' Unit # H Plans produced by: ID Plans 6/13/2017
More information