PRODUCT SPECIFICATIONS

Size: px
Start display at page:

Download "PRODUCT SPECIFICATIONS"

Transcription

1 CPLJ SERIES SEER SPLIT SYSTEM HEAT PUMP COOLING CAPACITY: 6, TO 6, BTU/H HEATING CAPACITY: 6, TO 6, BTU/H ½ TO TON The CPLJ features an attractive louvered metal guard that protect the coil from damage and strengthens the unit. Designed for ground-level or rooftop mount, the base pan elevates the unit above the slab for good water drainage. Standard Features Energy-efficient compressor with internal high-pressure relief Quiet operating top discharge Totally enclosed, permanently lubricated condenser motor Copper tube/aluminum fin coil Brass liquid and suction service valves with sweat connections Fully charged for of tubing length Factory-installed bi-flow liquid line filter dryer Discharge line muffler Suction line accumulator Check-flowrater expansion device Time-initiated, temperature-terminate defrost Low-pressure control for loss of charge protection Crankcase heater (where indicated) Cabinet Features Designed for ground-level or rooftop mount Polyester powder-paint finish provides premium durability and improved UV protection Heavy-gauge, galvanized-steel cabinet Louvered guard protects coil from damage and adds strength to unit Bottom pan rails elevate unit above slab When properly anchored, meets Florida Building Code unit integrity requirements for hurricane-type winds Air Handler and Coil Compatibilities ARUF, ARPF, and AEPF multi-position electric heat air handlers ADPF/ARPF dedicated downflow electric heat air handler AWUF vertical wall-mounted electric heat air handler ACNF ceiling-mounted electric heat air handler MBR/MBE modular blowers CA, CH and CS indoor coils SS-GCPLJ /6 Supersedes 7/

2 SPECIFICATIONS Model Nominal Cooling Capacity (BTU/h) Nominal Heating Capacity (BTU/h Service Valve Compressor Condenser Fan Liquid Suction Type RLA LRA Type HP FLA dbs Ship Weight (lbs) CPLJ8-B 8, 8, /8 / Sweat Reciprocating / CPLJ-B,, /8 / Sweat Reciprocating / CPLJ-B,, /8 / Sweat. 7. Scroll /6. 8 CPLJ6-B,, /8 / Sweat.7 8 Scroll /6.9 8 CPLJ-B,, /8 7/8 Sweat 8. 9 Scroll / CPLJ8-B 6, 6, /8 7/8 Sweat 8. 9 Scroll / CPLJ6-B 6, 6, /8 7/8 Sweat 8 Scroll /. 8 8 ELECTRICAL DATA Model MCA¹ MOD² Voltage-Phase Min. Volts Max. Volts CPLJ8-B.7 8/- 97 CPLJ-B. 8/- 97 CPLJ-B 8 8/- 97 CPLJ6-B 9. 8/- 97 CPLJ-B.8 8/- 97 CPLJ8-B.7 8/- 97 CPLJ6-B.8 8/- 97 ¹ Minimum Circuit Ampacity: Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ² Maximum Overcurrent Protection Device: May use fuses or HACR-type circuit breakers of the same size as noted SS-GCPLJ

3 DIMENSIONS Model Width Depth Height CPLJ8-B CPLJ-B CPLJ-B CPLJ6-B 9 9. CPLJ-B CPLJ8-B 9 9. CPLJ6-B 9 9. ACCESSORIES Item # CHTP8-6HD HPT8-6 OT/EHR8-6 OT8-6 Description Digital Room Thermostat with -stage cool/-stage heat Standard Room Thermostat with -stage cool/-stage heat Outdoor Lockout Thermostat/Emergency Heat Relay Kit for staging electric heat Outdoor Thermostat* * Required for all heat pumps if outdoor ambient temperature is F with % or higher relative humidity SS-GCPLJ

4 PERFORMANCE RATINGS Outdoor Unit CPLJ8-* CPLJ-* Indoor Unit Cooling Capacity Heating Capacity (BTU/h) BTU/h SEER¹ EER² High HSPF³ Low ARI # AC8-XX / ACNF8XXA* 6,.. 6, 7 9, 6778 AC-XX 6,8. 6, 7 9, 677 ADPF8** 8,. 8, 7., 8 AEPF8** 8,. 8, 7.8, 87 AEPT-*-* 8,. 8, 7.8, 7 ARPF6-B-* / ADPF8** 8,. 8, 7., 7 ARPF8** 8,. 8, 7., 8 ARPT-*-* 8,. 8, 7., 7 ARUF8-*-* 7, 9.7 7, 7 9, 799 ARUF-*-* / ARUF8** 8,. 8, 7., 7 AWB8-XX 7, 9.7 7, 7 9, 678 AWB-XX 7,. 7, 7. 9, AWUF8XXA* 7,. 7, 7. 9,6 89 CA*F** / CA*F8*6A*+EEP 8,. 8, 7., CHPFA* / CHPF8A6A* + EEP 8,. 8, 7., 9 H6F / CSCF8N6A*+ EEP 8,. 8, 7., 679 AC-XX,.., 7,8 669 AC-XX / ACNFXXA*,., 7, 66 AEPF8**,., 8.,6 89 AEPT-*-*,., 8.,6 7 ARPF6-B-* / ADPF8**,., 7.8,6 76 ARPF8**,., 7.8,6 8 ARPF**,., 7.8,6 8 ARPT-*-*,.., 7, 7 ARPT-*-*,., 7.8,6 7 ARPT-*-*,., 7.8,6 79 ARUF-*-*,., 7, 7 ARUF-*-* / ARUF8**,., 7.8,6 798 ARUF-*-* / ARUF**,., 7.8,6 7 AWB-XX / AWUFXXA*,.., 7, 66 AWB6-XX / AWUF6XXA*,., 7.,6 668 CA*F** / CA*F8*6A*+EEP,., 7.,6 67 CA*F** / CA*F*6A* + EEP,., 7.,6 679 CHPFA* / CHPF8A6A* + EEP,., 7.,6 67 H6F / CSCF8N6A*+ EEP,., 7.,6 67 ¹ Seasonal Energy Efficiency Ratio ² Energy Efficiency 8 F/67 F/9 F ³ HSPF = Heating Seasonal Performance Factor Notes: Order the EEP from the Service Department using Part No. B77-8 or new Solid State Board B77-S. Part No. B77-8 is not interchangeable with B77-S. When mix-matching outdoor and indoor units, the indoor unit check-flowrator must match the outdoor unit size. SS-GCPLJ

5 PERFORMANCE RATINGS (CONT.) Outdoor Unit CPLJ-* CPLJ6-* Indoor Unit Cooling Capacity Heating Capacity (BTU/h) BTU/h SEER¹ EER² High HSPF³ Low ARI # AC8-XX 9,. 9, 7. 7, 67 AC-XX 7,.. 6, 7, 66 AC6-XX / ACNFXXA* 7,. 6, 7,6 66 AEPF8** 9,. 9, 7.8 7, 8 AEPF6**,., 7.8 8, 88 AEPT-*-* 9,. 9, 7.8 7, 7 AEPT6-*-*,., 7.8 8, 7 ARPF6-B-* / ADPF8** 9,. 9, 7.8 7, 7 ARPF** 9,. 9, 7.8 7, 86 ARPT-*-* 9,. 9, 7.8 7, 7 ARPT-*-* 9,. 9, 7.8 7, 7 ARUF-*-* 7,. 7, 7,6 79 ARUF-*-* / ARUF8** 9,. 9, 7.8 7, 7 ARUF-*-* / ARUF** 9,. 9, 7.8 7, 78 AWB-XX 7,. 7, 7,8 666 AWB6-XX / AWUF6XXA* 9,. 9, 7.8 7, 66 CA*F** / CA*F8*6A*+EEP 9,. 9, 7. 7, 678 CA*F** / CA*F*6A* + EEP 9,. 9, 7. 7, 676 CHPFA* / CHPF8A6A* + EEP 9,. 9, 7. 7, 67 H6F / CSCF8N6A*+ EEP 9,. 9, 7. 7, 676 AC6-XX / ACNFXXA*, 9.7, 7 7, 667 AEPF6**,., 8, 8 AEPT6-*-*,., 8, 7 ARPF8-B-* / ADPF**,., 7.8, 7 ARPF**,., 7.8, 8 ARPT6-*-*,., 7. 9, 79 ARPT-*-*,., 7.8, 7 ARUF6-*-*,., 7. 9, 78 ARUF-*-* / ARUF**,., 7.8, 77 AWB6-XX / AWUF6XXA*,., 7. 9, 66 CA*F** / CA*F*6A* + EEP,., 7.8, 676 CHPFB* / CHPFB6A* + EEP,., 7.8, 67 CHPXB*+EEP,., 7.8, 677 H9F / CSCF6N6A* + EEP,., 7.8, 678 ¹ Seasonal Energy Efficiency Ratio ² Energy Efficiency 8 F/67 F/9 F ³ HSPF = Heating Seasonal Performance Factor Notes: Order the EEP from the Service Department using Part No. B77-8 or new Solid State Board B77-S. Part No. B77-8 is not interchangeable with B77-S. When mix-matching outdoor and indoor units, the indoor unit check-flowrator must match the outdoor unit size. SS-GCPLJ

6 PERFORMANCE RATINGS (CONT.) Outdoor Unit CPLJ-* CPLJ8-* CPLJ6-* Indoor Unit Cooling Capacity Heating Capacity (BTU/h) BTU/h SEER¹ EER² High HSPF³ Low ARI # AEPF6**,.79, 8., 8 AEPT6-*-*,.79, 8., 78 ARPF8-B-* / ADPF**,., 8, 78 ARPF6**,., 8, 8 ARPT-*-* 8,. 8, 7., 77 ARPT9-*-*,., 8, 76 ARUF-*-* 8,. 8, 7., 7 ARUF9-*-* / ARUF6**,., 8, 7 CA*F6** / CA*F6*6A* + EEP,., 8, CHPF6D* / CHPF86D6A* + EEP,., 8, 67 H6F / CSCF86N6A* + EEP,., 8, 67 AEPF6** 6,. 6, 8. 7, 88 AEPT6-*-* 6,. 6, 8. 7, 7 ARPF6-B-* / ADPF86** 6,. 6, 8 7, 7 ARPF6**,., 8, 8 ARPF86** 6,. 6, 8 7, 87 ARPT9-*-*,., 8, 7 ARPT6-*-* 6,. 6, 8 7, 79 ARUF8-*-*,.., 7., 7 ARUF9-*-* / ARUF6**,., 8, 7 ARUF6-*-* / ARUF86** 6,. 6, 8 7, 77 CA*F6** / CA*F6*6A* + EEP,., 8, 679 CHPF6D* / CHPF86D6A* + EEP,., 8, 676 H6F / CSCF86N6A* + EEP,., 8, 676 AEPF6** 6,. 6, 8., 8 AEPT6-*-* 6,. 6, 8., 7 ARPF6-B-* / ADPF86** 6,. 6, 8, 7 ARPF86** 6,. 6, 8, 8 ARPT6-*-* 6,. 6, 8, 7 ARUF6-*-*,., 7., 76 ARUF6-*-* / ARUF86** 6,. 6, 8, 76 CA*F6** / CA*F86*6A* + EEP 6,. 6, 8, 6879 CHPF6D* / CHPF86D6A* + EEP 6,. 6, 8, 687 H6F / CSCF86N6A* + EEP 6,. 6, 8, 687 ¹ Seasonal Energy Efficiency Ratio ² Energy Efficiency 8 F/67 F/9 F ³ HSPF = Heating Seasonal Performance Factor Notes: Order the EEP from the Service Department using Part No. B77-8 or new Solid State Board B77-S. Part No. B77-8 is not interchangeable with B77-S. When mix-matching outdoor and indoor units, the indoor unit check-flowrator must match the outdoor unit size. 6 SS-GCPLJ

7 HEATING PERFORMANCE EXPANDED 7 F INDOOR AMBIENT MODEL CPLJ8-B W: AC8-XX MODEL CPLJ8-B W: AC-XX MODEL CPLJ8-B W: ARUF MODEL CPLJ8-B W: AWB-XX MODEL CPLJ8-B W: H6F+EEP/ ARPF6/ ARPT/ ARUF/ AEPT MODEL CPLJ-B W: AC-XX MODEL CPLJ-B W: ARPF/ ARPT/ AWB-XX/ ARUF MODEL CPLJ-B W: AC-XX 6 MODEL CPLJ-B W: H6F+EEP/ AWB6-XX/ ARPF6/ARPT/ ARUF/ AEPT-A-/ ARUF/ ARPT 6 MODEL CPLJ-B W: AC-XX 6 MODEL CPLJ-B W: H6F+EEP/ AWB6-XX/ ARPF6/ ARPT/ ARUF/ARPT/ ARUF/ AEPT 6 MODEL CPLJ-B W: AC6-XX 6 MODEL CPLJ-B W: ARUF/AWB-XX MODEL CPLJ-B W: AEPT/AEPT6 MODEL CPLJ6-B W: AC6-XX SS-GCPLJ 7

8 HEATING PERFORMANCE EXPANDED 7 F INDOOR AMBIENT (CONT.) MODEL CPLJ6-B W: H9F+EEP/ ARPT/ ARUF/AEPT6 6 6 MODEL CPLJ6-B W: ARPT6/ARUF6/ AWB6-XX 6 MODEL CPLJ-B W: ARPT/ARUF 6 6 MODEL CPLJ-B W: AR8-XX/AEPT8/ AEPT6 6 6 MODEL CPLJ-B W: H6F+EEP/ARPF8/ ARPT9/ARUF MODEL CPLJ8-B W: ARUF8 6 MODEL CPLJ8-B W: ARPF8/ARPT9/ ARUF MODEL CPLJ8-B W: AEPT8/ ARPF6/ ARPT6/ ARUF6/ AEPT MODEL CPLJ6-B W: ARUF MODEL CPLJ6-B W: ARPF6/ ARPT6/ ARUF6/ H6F+EEP/ AEPT Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. Copyright 6 Goodman Manufacturing Company, L.P. Houston, Texas Goodman brand products are proudly made in the USA. Printed in the USA. 8 SS-GCPLJ

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS CPLT SERIES SPLIT SYSTEM HEAT PUMP SEER TO TON The CPLT features an attractive louvered metal guard to protect the coil from damage and strengthen the unit. Designed for ground-level or rooftop mount,

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS 16 SEER / R-410A HIGH-EFFICIENCY 2- TO 5-TON SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY: 24,000 BTU/H TO 57,000 BTU/H The Goodman 16 SEER Air Conditioner uses the environmentally friendly refrigerant

More information

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 Check flowrater for heat pump and cooling-only applications All-aluminun tube/aluminum

More information

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw] PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed

More information

CKL, CLJ, CRT, CLT, TWC, CLQ & HDC

CKL, CLJ, CRT, CLT, TWC, CLQ & HDC Service Instructions CKL, CLJ, CRT, CLT, TWC, CLQ & HDC Split System Remote Coolers and CPLE, CPLJ, CPRT, CPLT & HDP Split System Remote Heat Pumps with R-22 Refrigerant Blowers, Coils, & Accessories This

More information

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7 Multi-Position, Variable-Speed Air Handlers 1½ to 5 Tons Standard Features Suitable for use with R-410A and R-22 refrigerants Check flowrater expansion device for cooling and heat pump applications Variable-speed

More information

DSXC18 Split System Air Conditioner

DSXC18 Split System Air Conditioner DSXC18 Split System Air Conditioner up to 18 SEER Cooling Capacity: 34,000-56,000 BTU/h * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Compressor

More information

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump RTG Ultron Split System Heat Pump Specification Sheet Up to 16 SEER Cooling : 35,000-56,500 BTUH Heating : 33,600-56,400 BTUH LIMITED WARRANTY Lifetime Replacement of Entire Unit if Compresssor Fails 10-Year

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

2 shp 13 lc 1 36 t - 1 a

2 shp 13 lc 1 36 t - 1 a HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =

More information

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton AEPT SERIES Multi-Position, Variable-Speed High-Efficiency Air Handler 2 and 5 Ton The AEPT air handler is compact for versatile upflow/downflow or horizontal multi-position installations and may be located

More information

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet Air Conditioning and Heating SPECIFICATION sheet MHH 13 SEER High Efficiency R410a Split System Heat Pump Standard features: R410a system High efficiency compressor Compact design for easy installation

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity TECHNICAL SPECIFICATIONS DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System 1.5-5 Ton The DT5BD Series of heat pumps offers exceptional performance. The heat pump, when combined with our

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model DS4BD Series M120 Product Line High Efficiency R-410A Air Conditioner 13+ SEER 1.5-5 Ton Capacity 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise

More information

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton AEPT SERIES Multi-Position Air Handler 2 to 5 Ton The AEPT multi-position air handler is approved for modular homes and may be installed in a utility room, closet, aclove, basement or attic. Standard Features

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN 4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF FORM NO. 4HP15L-100 (12/2018) COILS Omniguard total corrosion protection technology designed coil Enhanced

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Goodman Air Handler Wiring Diagram

Goodman Air Handler Wiring Diagram GOODMAN AIR HANDLER WIRING DIAGRAM PDF - Are you looking for goodman air handler wiring diagram Books? Now, you will be happy that at this time goodman air handler wiring diagram PDF is available at our

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity TECHNICAL SPECIFICATIONS JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System 1.5-5 Ton Capacity The JS5BD Series of air conditioners offers exceptional performance. The unit,

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW ADPF THREE-SPEED AIR HANDLER The ADPF Dedicated Downfl ow Three-Speed Air Handler is suitable for use with refrigerants R-410A and R-22. The unit features a check flowrater expansion device and may be

More information

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting track for quick repositioning Optimized for

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model DT4BD Series M120 Product Line High Efficiency R-410A Heat Pump 13 SEER 1.5-5 Ton 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace

More information

N4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors

More information

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor Contents Nomenclature... 2 Accessories... 2... 3 Dimensions... 4 Airflow Data... 5 Heat Kit Data... 6 Wiring Diagram... 8 Series Product Features Internal factory-installed thermal expansion valves for

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

13 SEER CONDENSING UNITS & AIR HANDLERS

13 SEER CONDENSING UNITS & AIR HANDLERS 13 SEER CONDENSING UNITS & AIR HANDLERS (GC201305-I) TTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CON TECHNICAL SALES GUIDE-60Hz CAPACITY RANGE:11/2~5

More information

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum FORM NO. P11-774 REV. 3 Supersedes Form No. P11-774 Rev. 2 Featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant 13PJL SERIES 13 SEER HEAT PUMPS Features Coils constructed with copper

More information

residential PRODUCTS CATALOG

residential PRODUCTS CATALOG residential PRODUCTS CATALOG Featuring: Premium Amana Quality Since 1934 Featuring: Products Built to Last and Last and Last Featuring: MILLION-AIR Heat Exchanger and SureStart Ignition System Featuring:

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Condensing Units & Air Handlers

Condensing Units & Air Handlers Condensing Units & Air Handlers 13 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice. Copyright

More information

13 SEER CONDENSING UNITS

13 SEER CONDENSING UNITS FORM NO. A11-182 REV. 8 Supersedes Form No. A11-182 Rev. 7 13 SEER CONDENSING UNITS Features Painted louvered steel cabinet. Easily accessible control box. Condenser coils constructed with copper tubing

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PSH4BF Series M1010 Product Line R-410A Ultra High Efficiency Heat Pumps 15+ SEER 2-5 Ton 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY PROMISE Maytag

More information

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF T-CLASS True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models Up to 15.0 SEER, and 9.0 HSPF Control operational costs with reliable, energy-efficient split systems

More information

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons ANF Series eiling-mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 heck flowrater for heat pump and cooling-only applications All-Aluminum tube/aluminum

More information

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER T-Class True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models Up to 16.2 SEER and 9.7 HSPF Control operational costs with reliable, energy-efficient split systems

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

TZPL SERIES. Applications Thermal Zone remote heat pumps offer comfort and dependability for single, multi-family and light commercial applications.

TZPL SERIES. Applications Thermal Zone remote heat pumps offer comfort and dependability for single, multi-family and light commercial applications. FORM NO. PTZ-786 Supersedes Form No. PTZ-765 Rev. 2 TZPL SERIES Manufactured for Thermal Zone Philadelphia, PA 13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum fins.

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION AIR CONDITIONERS 2scu3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20644 May 204 Supersedes September 203 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 scu 3 lc 36 t - a Refrigerant

More information

Specifications and Performance S2H

Specifications and Performance S2H DUCTLESS SPLIT SYSTEM Dual-ZONE Heat Pump CONDENSING UNIT P/N# 240006613, Rev. A [06/08] Specifications and Performance Heat Pump Nominal Capacities: 9,000 and 12,000 Btuh DESCRIPTION EMI offers the finest

More information

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability T-Class AC and HP Units Up to 15.00 SEER and 9.0 HSPF T-Class Commercial Air Conditioners and Heat Pumps TSA/TPA Models True performance and rugged durability Control operational costs with reliable, energy-efficient

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability T-CLASS Performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF Control operational costs with reliable, energy-efficient split systems

More information

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models S-Class The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models Up to 16.7 SEER and 9.5 HSPF Superior efficiency for more of what you want, less of

More information

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan Submittal Data Form Job Name DCC Series 3-6 Ton Packaged Air Conditioner 13 SEER / Up to 11.3 EER 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity: 34,600 71,000

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons ACNF Series Ceiling-Mounted Air Handlers 1½ to 2½ Tons Contents Nomenclature...2 Heat Kit Data...2 Product Specifications...3 Dimensions...5 Airflow Data...5 Wiring Diagram...6 Accessories...8 Features

More information

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER DCC Series Submittal Data Form Job Name 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By:

More information

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS 23 SEER Residential System Indoor Section M1200 Product Line PAH2VM Series Variable Speed Air Handler C5 Series Residential Indoor Coils with EXV 2 M1200 12 YEAR ALL PARTS LIMITED

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER DSC Series Submittal Data Form 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Standard

More information

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS 072, 090, 120, 180 & 240 MODELS C SERIES P SERIES HEAT PUMPS SPLIT L SERIES SYSTEMS LSA Condensing Units 6 Thru 20 Ton (21.1 Thru 70.3 ) Heat Pumps 7.5 & 10 Ton (26.4 & 35.2 ) Bulletin #210164 February

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor ComfortNet Communicating System compatible Auto configuration

More information

HEAT PUMPS UPNL- FORM NO. P REV. 5 Supersedes Form No. P Rev. 4

HEAT PUMPS UPNL- FORM NO. P REV. 5 Supersedes Form No. P Rev. 4 FORM NO. P22-768 REV. 5 Supersedes Form No. P22-768 Rev. 4 HEAT PUMPS UPNL- 13 SEER Models Nominal Sizes 1 1 /2 to 5 Tons [5.28 kw] to [17.6 kw] Seven Models Cooling Capacities 18,200 to 60,500 R [5.33

More information

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCG Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant

More information

16 SEER TWO-STAGE AIR CONDITIONERS

16 SEER TWO-STAGE AIR CONDITIONERS FORM NO. ATZ-210 Supersedes Form No. ATZ-210 16 SEER TWO-STAGE AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT 50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 1 Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s)

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

AVPTC. Air Handlers 1½ to 5 Tons

AVPTC. Air Handlers 1½ to 5 Tons Multi-Position, Variable-Speed Air Handlers ½ to Tons Standard Features Compatible with the ComfortNet Communicating System family of products R-0A refrigerant-compatible Factory-installed thermal expansion

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion 38ARZ/ARD Commercial Air-Cooled Split Sizes 007-028 With 40RM007-028 6-25 Nominal Tons - 50Hz Product Data The 38ARZ/ARD condensing units with scroll compressors match Carrier s 40RM indoor-air handlers

More information

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out AC, HP and Air Handler Units Up to 20 Tons T-Class Commercial Split Systems TSA/TPA and TAA Models Reliable, cost-effective and servicefriendly split systems inside and out Lennox units deliver comfort

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S E N G I N E E R I N G D A T A H E A T P U M P O U T D O O R U N I T S 13HPD MERIT SERIES R 22 Bulletin No. 210428 March 2009 Supersedes April 2008 SEER up to 14.5 1.5 to 5 Tons Cooling Capacity 18,500

More information

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models FORM NO. A22-188 REV. 3 Supersedes Form No. A22-188 Rev. 2 CONDENSING UNITS JEZ 16 Two- Models Efficiencies up to 17.10 Nominal Sizes 2 to 5 Tons [7.03 kw] to [17.06 kw] Four Models Cooling Capacities

More information

seer 4HP16LT Split System Enhanced Heat Pump Features and Benefits WARRANTY

seer 4HP16LT Split System Enhanced Heat Pump Features and Benefits WARRANTY Split System Enhanced Heat Pump 16 COMPRESSOR High-efficiency 2 stage Copeland Ultra Tech scroll compressor R410a refrigerant Grommet mounted compressor for quiet operation Internally protected against

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons) ENGINEERING DATA HEAT PUMP OUTDOOR UNITS HP40 50HZ Capacity 6.2 to 16.3 (21 200 to 55 500 Btuh) Heating Capacity 6.4 to 16.1 (21 800 to 55 500 Btuh) Bulletin No. 490088 October 2004 Supersedes August 1999

More information