TrueClean Compact CIP
|
|
- Daniel Allison
- 6 years ago
- Views:
Transcription
1 TrueClean Compact CIP Installation, Operation, and Maintenance Manual
2 TrueClean Compact CIP Table of Contents Safety... 1 Important Safety Information Introduction... 2 About This Manual... 2 Application... 2 Technical Data... 2 Built-in Safety... 3 Installation... 4 Air Connections Operation Control Panel... 5 System Start Operation Screens HMI Statuses Explained Maintenance Maintenance Checklist Replacing Components Replacing Poly Tubing Replacing Pressure Regulator Filter Element Replacing Solenoid Valve Troubleshooting Warranty i
3 Safety Important Safety Information Read this manual before installing, operating, and maintaining this equipment. Failure to read the manual can result in personal injury and/or equipment damage. Do not attempt to remove and/or modify any TrueClean products or programming. Doing so can create unsafe conditions for the operator(s) and/or surrounding persons. Any change to TrueClean products or programming will void any and all warranties. Do not place any TrueClean product in an application where general product service ratings are exceeded. Doing so puts the operator(s) and/or surrounding persons at risk of personal injury and/or result in equipment damage. The words DANGER, WARNING, and CAUTION and their meanings, as used within these instructions, are listed below: DANGER WARNING CAUTION Indicates an imminently hazardous situation, which if not avoided, has a high likelihood of resulting in death or serious injury. This symbol is used in only the most extreme at-risk cases and warrants immediate action. Indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury. This symbol is used for moderately at-risk cases and warrants immediate action. Indicates a potentially hazardous situation, which if not avoided, may result in minor or moderate injury. This symbol may also be used to alert against an unsafe operating or maintenance practice. If, at any point during operation a Danger, Warning, or Caution indication is present, the operator should immediately take steps to resolve the problem and/or seek assistance from a supervisor. Do not remove labeling on any TrueClean product. The customer should replace any missing labels right away. Disclaimer of Liability TrueClean does not assume responsibility and expressly disclaims liability for loss, damage, or expenses that arise in any way from the installation, operation, use, or maintenance performed in accordance with this manual. TrueClean assumes no responsibility for any infringement of patents or other rights of third parties that may result from use of the module. No license is granted by implication or otherwise under any patent or patent rights. TrueClean reserves the right to make changes to the product, specifications, or this manual without prior notice. 1
4 Introduction Thank you for purchasing a TrueClean product. This manual contains operation instructions for the TrueClean CIP control system. About This Manual This manual covers the complete line of TrueClean s Compact CIP control systems. All Compact CIP systems are available, along with optional equipment that can provide additional functionality. For questions or concerns regarding the Compact CIP control system, contact TrueClean at or Application TrueClean s Compact CIP control system is a powerful, economical, and efficient way to regulate the operation of a clean-in-place (CIP) system. The Compact CIP control system takes the guesswork out of configuring and selecting the desired start, stop, flow, temperature, and chemical concentration required to have a successful clean-in-place (CIP) cycle. Technical Data Maximum Compressed Air Pressure Air Inlet Size Maximum Product Pressure Product Temperature Range Electrical Requirement Amperage Requirement Based on System Configuration 100 psig 1/2 FNPT 145 psig 0 F 180 F AC 480V, 60Hz +/- 6% 20 amps without electric heat, 57 amps with electric heater option 2
5 Introduction Built-in Safety Each control unit has built-in, integrated safety features including air lockout complying with Occupational Safety and Health Administration (OSHA) lockout/tagout procedures. In case of emergency, the emergency stop capabilities provide a way to halt all operations. Control units can also incorporate system timeouts, providing added protection for operators. Air Lockout Capability When the air is in the off position, a pad lock can be attached to the air switch to prevent accidental operation. This complies with OSHA lockout/tagout procedures E-Stop Capability When the E-stop is activated, all operations are stopped. To release the E-stop, twist in a clockwise rotation until the piece pops up. 3
6 Installation The CIP control cabinet will arrive mounted to the skid and pre-wired to any instruments installed on the skid. Typical installation requires a dedicated 480V 3-Phase with sufficient amperage for the control system (20 amps for a standard unit and 57 amps for an unit with an electric heater) and branch circuit protection. Electrical schematics will be provided with the control panel for the Compact CIP control system. The drawings will indicate the location, voltage, and amperage requirement for the panel. The CIP control system is designed to work as a stand-alone system and does not require any integration with the plants infrastructure. WARNING To avoid electrocution, a registered electrician should do all electrical work. Industrial safety standards and local codes should be followed. All power must be off and safely locked out during installation. Air Connections Air Input to Cabinet Air connection 1/2 NPT Female 90 psi minimum Note: TrueClean recommends that the cabinet be supplied with clean instrument air at the minimum pressure and flow rate for your application. 4
7 Operation Control Panel In this section, you will find instructions regarding selecting the wash parameters and starting a cleaning cycle through the use of the touch screen control panel. System Start a. Verify all swing, hose, and piping connections have been made. b. Verify the air relief switch is in the on position. c. Verify the E-Stop is not activated. d. To change wash parameters, press the Config button, which will display a user login screen. I. Input user name and password. II. Default login to change configuration parameters: i. User: engineer ii. Pass: engineer III.. After logging in, a screen to adjust the desired wash settings for temperature, flow, and chemical concentration will be displayed. IV. Make the desired configuration changes, and press the Logoff button. This logouts the elevated user and returns to standard user credentials. e. Before starting the system, double-check that all process connections have been made and return to drain is connected and routed appropriately. Press the Commands button, and the system will present the available washes. I. Select the desired wash type on the left. When ready, press the Start button on the right. II. As a safety precaution, if an issue arrises during the wash, the operator can press the Abort button to cancel the current wash. III. If the operator wishes to pause, but not cancel the wash, the Hold button can be pressed. This will pause the current wash sequence, but will keep the current position and time remaining. To resume the wash, press the Restart button, and the system will resume operation. f. When the system is started, it will automatically open the water fill valve and will maintain tank level based on the tank settings, located on the Config screen. g. The system will continue to run in automatic mode until the operator stops the system by pressing the Abort button, Hold button, or E-Stop button. The system will also stop running in automatic mode if the system goes into a Tank High Limit Alarm state. I. If the system goes into alarm, the issue that caused the alarm must be resolved. For Tank High Limit Alarms, the operator must acknowledge the alarm before the skid can be operated again. Transmitter errors and Tank Low Level Limit Alarms auto-acknowledge themselves once the problem has been resolved. 5
8 Operator Interface Screens Figure 1 - Main Screen The main screen displays all system statuses in an intuitive manner: 1. The main navigation bar is located at the top of every screen. 2. When equipment (such as valves and pumps) is running or open, the color will change to green. When equipment is closed or stopped, the color will change to red. The electric heater, if equipped, will turn red when the power has been supplied to the heater and will also display Heater On text above it. 3. In the top left corner of the screen, there is a grey area that contains system statuses. The statuses provide the following possibilities: a. Current Wash Phase This describes the current wash phase the system is currently running. This lets the operator know which part of the wash cycle they are in. Wash phases can be one of the following; system idle, pre-rinse running, caustic running, rinse running, acid running, system draining, final rinse running, and sanitizer running. b. Current Wash Conditions Each phase of the wash has its own configured setpoints. These items will display on the screen when there is a need to wait for setpoints to be met: Waiting Cond. SP, Waiting Temp SP, Waiting Temp & Cond. SP. Wash Conditions Met will display once the setpoint has been reached. Setpoints are described in greater detail at the bottom of page 9. c. Time Remaining This is the time remaining, in seconds, of the current wash phase. If the timer is not counting down while the system is running, then the system is waiting for a wash condition, such as temperature or conductivity, to be met. 4. The system will auto-maintain its tank level according to the tank settings configured on the Config screen. a. The water supply to the skid needs to be capable at filling the same or greater rate as the CIP supply pump for effective rinsing. For example, the standard pump is rated for 50 gpm at 50 psi, so the supply water to the skids should be at least 50 gpm to maintain level. 6
9 Operator Interface Screens 5. When the system is sitting idle, without any active alarms, the operators are allowed a small amount of manual control of the system, as long as the built-in interlocks are complied with. Press the equipment object button to open or turn on that piece of equipment. The equipment will only turn on or open if the interlock permissions are correct. Press again to close or shut off the valve. Refer to the Interlocks/Alarms section on p. 20 for more information. Figure 2 - Configuration Screen The configuration screen displays system settings that can be adjusted to the desired CIP wash parameters. 1. Time SP This is the desired hold time the wash conditions require before the system can move on to the next wash phase. 2. Temp SP Only caustic and acid wash phases require a temperature setpoint is met before the timer can countdown. 3. Cond. SP This is the desired setpoint of the chemical conductivity level needed to achieve an ideal concentration. Caustic and acid phases have to be over their configured setpoints, while pre-rinse, rinse, final-rinse, and sanitizer phases need to be below their configured setpoints. 4. Flow SP This is the desired flow rate of the CIP system for all wash phases. 5. Chem SP This system is designed to pulse in small amounts of chemicals at a time and bring the whole CIP loop up to concentration, rather than initially dosing a large amount of chemicals and potentially overshooting concentration targets. If the system is configured for automated chemical dosing, the following things will appear: a. Cycle Time How often the chemical pump will dose chemical during a caustic or acid wash phase. The default is 10 seconds. 7
10 Operator Interface Screens b. Pulse Caustic How long the chemical pump stays on when it doses caustic chemicals during a caustic wash phase. The default is two seconds. c. Pulse Acid How long the chemical pump stays on when it doses acid chemicals during a caustic wash phase. The default is two seconds. 6. Tank Options Configures how the tank level operates when the system is active. a. High Limit Tank High Level Fill Alarm setpoint. System will alarm and abort any current washes if the tank becomes overfilled. b. Stop Fill When the system is refilling with fresh water, it will stop filling at this setpoint to prevent overfilling the tank. The default is 80%. c. Start Fill When the system is running and the tank volume falls below this amount, the water inlet valve will open and start refilling the system until it reaches the configured Stop Fill amount or the current wash phase completes. d. Low Limit Tank Low Level Limit Alarm setpoint. The system will output a warning if the tank volume falls below this amount, and the pump will be inhibited to run until the level in the tank is returned to a normal amount. This is by design, to prevent the pump seals from running dry. 7. System Options These will be set at the factory with the options purchased with the system. a. Has Automated Valves Allows the system to run through the wash phases and maintain tank level without operator intervention. b. Has Electric Heat Allows the system to heat and maintain temperature during the caustic and acid phases of the wash cycle. c. Has Caustic Pump Allows automated chemical dosing of caustic during the caustic wash phase. d. Has Acid Pump Allows automated chemical dosing of the acid during the acid wash phase. Wash Criteria The criteria that need to be met for the wash timer to count down and complete a specific wash phase. If the system is running and the timer is not counting down, then one of the below criteria is not being met based on the configured wash settings. 1. Pre-Rinse a. Flow rate has to be greater than or equal to configured Flow SP. b. Chemical conductivity has to be less than the configured Cond. SP. c. The system has to be running and not in the held state. 2. Caustic a. Flow rate has to be greater than or equal to configured Flow SP. b. Chemical conductivity has to be greater than or equal than the configured Cond. SP. c. Return temperature has to be greater than or equal to the configured Temp SP. d. The system has to be running and not in the held state. 8
11 Operator Interface Screens 3. Drain a. Tank level has to be below 5% before the timer starts counting down. b. Chemical conductivity has to be less than or equal than the configured Cond. SP to prevent higher than desired chemical concentrations to be sent directly to the drain. c. Return temperature has to be less than or equal than the configured Temp SP to prevent higher than desired water temperatures to be sent directly to the drain. d. The system has to be running and not in the held state. 4. Rinse 5. Acid a. Flow rate has to be greater than or equal to configured Flow SP. b. Chemical conductivity has to be less than the configured Cond. SP. c. The system has to be running and not in the held state. a. Flow rate has to be greater than or equal to configured Flow SP. b. Chemical conductivity has to be greater than or equal than the configured Cond. SP. c. Return temperature has to be greater than or equal to the configured Temp SP. d. The system has to be running and not in the held state. 6. Final-Rinse a. Flow rate has to be greater than or equal to configured Flow SP. b. Chemical conductivity has to be less than the configured Cond. SP. c. The system has to be running and not in the held state. 7. Sanitizer a. Flow rate has to be greater than or equal to configured Flow SP. b. Chemical conductivity has to be less than the configured Cond. SP. c. The system has to be running and not in the held state. Note: Most sanitizers used in the sanitary industry don t have a good conductivity profile, so typical operation of this system is to dose the desired amount of sanitizer in the tank at the beginning of a sanitizer wash phase. 9
12 Operator Interface Screens Wash Types 1. Caustic Wash Phases included are pre-rinse, caustic, drain, and final-rinse. 2. Caustic Sanitizer Wash Phases included are pre-rinse, caustic, drain, final-rinse, and sanitizer phases. 3. Caustic Acid Wash Phases included are pre-rinse, caustic, drain, rinse, acid, drain, and finalrinse phases. 4. Caustic Acid Sanitizer Wash Phases included are pre-rinse, caustic, drain, rinse, acid, drain, final-rinse, and sanitizer phases. 5. Sanitizer Wash Phase included is the sanitizer phase. Wash Commands Figure 2 - Commands Screen 1. Start Starts the automated sequence of the selected wash type. 2. Hold When the system is running, the operator can put the system in a hold state. This will stop the active wash, but maintain the current timers, so the system can restart from where it was paused without starting the sequence over. 3. Restart When the system is in the held position, the operator can resume the current wash from where they left off. 4. Abort Will shut down the system canceling the active wash and bring the system into an idle state. This may also happen if a High Limit Alarm goes active or an operator presses the E-Stop button on the control panel. 10
13 Operator Interface Screens Starting Your First Wash Cycle 1. Select the desired wash type. 2. The selected wash is now displayed at the top. Prior to starting the wash, the operator can change the desired wash type. 3. When ready, press the Start command. Figure 3 - Commands Screen 3. Figure 4 - Commands Screen 4. The Start button will momentarily turn green, until the system is running. 11
14 Operator Interface Screens 5. Once the system is running, the Hold and Abort buttons will be available (if needed) during the wash cycle, and the operator can return to the Main screen to monitor skid operation. Figure 5 - Commands Screen Figure 6 - Trend Screen 6. The Trend screen logs the process values of supply flow, supply temperature, return temperature, and return conductivity. These data points are sampled every second and plotted on the same graph for wash monitoring. 12
15 Operator Interface Screens Figure 7 - History Screen 7. The History screen logs the actual process valves of supply flow, supply temperature, return temperature, and return conductivity exactly as the Trend screen does, except the data points are sampled every eight seconds, allowing the History screen to monitor a longer time frame (i.e. a complete wash cycle). Both the History and Trend screens are limited to 500 data points. Figure 8 - Alarm Screen 8. When the system has an active alarm, the Alarm button will flash red on every screen, indicating that there is a system problem. The skid will abort any current washes and return itself to an idle state. By pressing the Alarm button on the main navigation, you will be presented with the Alarm screen. On the main screen, a small red bell will also display next to the piece of equipment currently in an alarm state. 13
16 Operator Interface Screens Figure 8 - Alarm Screen 9. This screen displays the system alarms built into the Compact CIP system. Any active alarms will turn red and receive an illuminated border. Transmitter errors and tank low level alarms will auto-acknowledge once the problem has been resolved, however there are an additional four alarms that require an operator to acknowledge the alarm before the system can operate again. If the alarms do not clear, then the issue that caused the alarm is still in effect. 14
17 Operator Interface Screens Alarm Statuses Explained Pump VFD Fault The VFD in the control panel has a fault. This can be loss in Ethernet communication, such as when a new program is downloaded. It could also be a true VFD fault, such as overcurrent from a failing motor. High Temp Alarm The system is set to a max temperature of 180ºF. If temperature exceeds 180ºF, the High Temp Alarm will go active and any current washes will abort. High Cond. Alarm The system is set to a max chemical conductivity of 50mS/cm. If chemical conductivity exceeds 50mS/cm, the High Cond. Alarm will go active and any current washes will abort. Low Flow Alarm The system is powered on and running in automatic mode, and the supply flow is below the desired setpoint range. Tank High Level Alarm The system has a configurable Tank High Level limit, which is set to 100% as default. Tank level of 100% is set at the factory to be about two or three inches below the overflow in the tank. If the tank level reaches higher than the configured setpoint, the High Tank Level Alarm will go active and any current washes will abort. Tank Low Level Alarm The system has a configurable Tank Low Level limit, which is set to 10% as default. If the tank level drops below the configured setpoint, the supply pump will be interlocked to prevent it from running, and the Low Level Warning Alarm will go active. The current wash will not abort with this alarm, but will hold the system and wait for the tank level to return. This is done in an effort to complete the wash. Note: For effective rinsing, the water supply to the skid needs to be capable at filling at the same or greater rate as the CIP supply pump. For example, the standard pump is rated for 50 gpm at 50 psi, so the supply water to the skids should be at least 50 gpm to maintain level. Transmitter Errors - Return Temp, Supply Temp, Conductivity, Flow, Level If the analog signal goes below or above the normal operating range of 4-20mA, the system assumes there is a problem with the transmitter. The transmitter alarm will activate, and any current washes will abort. Once the transmitter is fixed and receiving the 4-20mA analog range, the alarm will automatically clear itself. 15
18 Operator Interface Screens Interlocks Explained When an interlock is active on a device in the system, a small stop sign with a P will display on the screen next to the piece of equipment that has an active interlock. The P stands for permission. E-Stop Active When the system is powered on and the E-Stop button has been activated, the system will shut down and inhibit all devices from operating until the operator has released the E-Stop button by twisting the button clockwise. There is also an E-Stop active status on the screen. Interlock - CIP Supply Pump The CIP supply pump has the following interlock criteria that need to be met prior to the pump operating. 1. The system is not in an E-Stop condition. 2. The pump is not in alarm. Figure 8 - Main Screen - E-Stopped 3. The tank discharge valve is commanded to be open. 4. The tank level has more liquid than the minimum configured Tank Low Limit set under Tank settings on the Configuration screen. (Default is 10% level.) 16
19 Operator Interface Screens Interlock Electric Heater If Equipped The electric heater has the following interlock criteria that need to be met prior to the heater being allowed to operate. 1. The system is not in an E-Stop condition. 2. The heater is not in alarm. 3. The CIP system is in a running state status. 4. The CIP supply flow is greater than 10 gpm. 5. The CIP supply temperature is less than 180ºF. Interlock Chemical Pumps If Equipped The chemical pumps have the following interlock criteria that need to be met, prior to them being allowed to operate. 1. The system is not in an E-Stop condition. 2. The heater is not in alarm. 3. The CIP system is in a running state status. 4. The CIP supply flow is greater than 10 gpm. 5. The CIP return chemical conductivity is less than 50ms/cm. 17
20 Maintenance WARNING Employees should not perform maintenance on the CIP control system before ensuring a safe work environment as outlined below: To ensure a safe work environment, it is recommended, but not limited to, verifying the following precautions are met: o Power to the control panel should be off and locked out. o Remove or lock out the inbound air supply from the pressure regulator. General cleanliness will extend the life of your control panels and its components. Where possible, the area should be kept free of spills and loose debris. Under no circumstance should the panel be sprayed down or cleaned with any wet fluids. Doing so could damage the electrical and/or pneumatic equipment. If any hardware issues exist, cease any and all use of the CIP control panel until all issues are resolved. Maintenance Checklist: o Check air lines for cracks and leaks. o Check pressure drop across air filter. If pressure drop exceeds maximum allowable, the filter needs to be cleaned or replaced. Note: The pressure drop should not exceed 14 psig. If the pressure drop exceeds the maximum allowable, the filter needs to be cleaned or replaced. o Check for loose connections or connectivity concerns regarding the solenoid valves. Note: A solenoid valve will not likely give advanced warning before failing. 18
21 Maintenance Replacing Components The instructions below describe how to replace components used in the manufacturing of TrueClean s CIP control system. Replacing Poly Tubing To replace poly tubing, follow the below instructions: a. Disconnect the inbound air line at the pressure regulator and ensure that the control panel is powered down. b. Press the outer ring of the pneumatic fitting in, and then gently pull the cracked or leaking air line from the fitting. c. Repeat the same procedure for the other end of the air line. d. Use the cracked or leaking air line as a guide for the length of the new air line. e. Trim the new section of air line to the appropriate length. f. Install air line by pressing each end into pneumatic fittings. Note: After the new line is pressed in, the outer rings on the pneumatic fittings need to extend. If they are not fully extended outward, when subjected to sufficient pressure, the hose could be blown out from its seated position. Replacing Pressure Regulator Filter Element SMC, the manufacturer of the supplied filter regulator, recommends the filter element be changed every two years or when the pressure drop across the element exceeds 14 psig. To replace the pressure regulator filter element, follow the below instructions: a. Locate the spring-loaded release on the front of the pressure regulator. b. Press the release down and hold. c. Turn the portion of the pressure regulator body below the spring-loaded release. o This may be more easily accomplished by holding the release with the thumb of the hand with which you intend to turn the body. o The pressure regulator body should only need to turn approximately half of a revolution before the operator can gently pull it free. Note: If you only turn the body a quarter of a turn, the release may try to extend back into place. d. Once the body of the regulator is removed, the element can be easily removed and replaced. e. Put the body back on and turn it back into position directly opposite of how you removed it. This should seat the body exactly where it began. 19
22 Maintenance Replacing Solenoid Valve Although solenoid valves used by TrueClean are rated for one million cycles, there are no performance guarantees for these items. While we do not guarantee a particular number of cycles, we are confident the valves will be free from manufacturer defects. To replace a solenoid valve, follow the below instructions: a. Remove retaining screws from the existing solenoid valve. Note: Keep them until you are certain new screws have been provided. b. Gently remove the solenoid valve from the mounting pad. o Take note of how the solenoid valve is oriented. o Take note of any and all o-rings, as there may be small o-rings on sealing surfaces. o In some cases, the top or bottom of the solenoid valve may need to come out first. c. Verify the o-rings are properly placed on the new solenoid valve. d. It may be necessary to insert or seat one end of the solenoid valve before the other end will seat properly. Note: It should never be necessary to force the new solenoid valve into place. e. Install the retaining screws that you removed in step (a). If new retaining screws were provided, use them and discard the screws from step (a). Note: If at any point you have questions or concerns regarding the CIP 2.0 Control System, please contact TrueClean at or
23 Troubleshooting Q. What should I do if the automated valves are not operating? A. Try the following solutions: 1. Ensure that the OSHA air dump valve is in the on position and the supply pressure is over 80 psi. 2. Ensure your Configuration settings have not been changed and the setting for System has Automated Valves is turned on. Q. What should I do if I cannot run the CIP pump? A. Try the following solutions: 1. Check the CIP supply pump interlocks, and ensure all criteria to operate has been met. 2. Ensure the VFD is not faulted and the E-Stop is not inhibiting its operation. 3. The supply pump can sometimes airlock when the system first starts and the process lines are dry. Command the current wash to hold and wait for the pump to stop, and then press Resume command. This will often clear the airlock of the pump. 4. Ensure the pump is rotating with the correct rotation and with the system safely locked out, ensure the pump impeller spins freely without interference or resistance. Q. What should I do if I cannot run the heater? A. Try the following solutions: 1. Verify that the supply flow is greater than 10 gpm; this is a safety feature to ensure there is adequate water flow for the heater to run. 2. Ensure the control system temperature setpoint is set on the desired temperature and that the return temperature is lower than that value. 3. Ensure the thermostat in the heater housing is set to the desired temperature. Please Note: If at any point you have questions or concerns regarding your CIP Control system, please contact TrueClean at or
24 Warranty A. GENERAL PROVISIONS: Central States Industrial Equipment & Service Inc. (hereinafter referred to as the Company) warrants to the original purchaser-used (hereinafter referred to as the Customer) that equipment or parts thereof manufactured by it will be free from defects in material and workmanship only, under normal use and service, for a period of one (1) year from the original shipment date. The Company shall not be liable for any loss of profit, loss by reason of plant shutdown, non-operation or increased cost of operation, loss product or materials, or other special or consequential loss or damages. This warranty will not apply to any equipment (or parts thereof), which has been subjected to accident, alteration, abuse or misuse. This warranty is in lieu of all other warranties, expressed or implied (including the implied warranty of merchantability and fitness) and of all other obligations or liabilities on the part of the Company, and the Company will neither assume nor authorize any other person to assume for it any other obligation or liability in connection with this equipment. In the event of a breach of warranty our liability shall be limited to the purchase price of the part(s) that have failed. B. RETURN OF PARTS OR EQUIPMENT TO COMPANY PLANT: Permission to return any parts or equipment must be obtained, in writing, and must be returned with transportation cost prepaid. In the event that equipment (or parts thereof) manufactured by the Company is returned to the plant, the Companies obligation will be limited to repairing or replacing parts, which upon examination are found (to the satisfaction of the Company) to be defective in either material or workmanship. No transportation will be paid by the Company unless written approval for transportation charges is given by the Company. C. COMPONENTS NOT MANUFACTURED BY THE COMPANY: Components not manufactured by the Company, but furnished as part of its equipment (for example: valves, controls, gauges, electrical switches or instruments, etc.) will be warranted by the Company only to the extent of the Component manufacturer s warranty. D. REPAIR OF EQUIPMENT INSTALLED IN THE CONTINENTAL UNITED STATES: Should an in-warranty failure occur, and it is, in the judgment of the Company, impractical to return the equipment for repairs, the Company will arrange for the repairs to be made by its personnel or, at its option, sublet to a qualified company. The Customer will be expected to cooperate by making the equipment available and accessible when the work is scheduled and is expected to provide the necessary utilities. If local labor conditions prohibit such work being done by Company personnel under the conditions and at the rates payable by its contracts with its employees, the Company obligation shall be limited to supervision of the work, replacement of defective parts, and labor costs in an amount equal to the amount which would be payable for a reasonable number of hours required to make the repairs at the rates payable under the terms of Company contracts with its employees. In such events, all labor costs shall be paid by the Customer and the Company will reimburse him to the extent set forth above. E. REPAIR OF EQUIPMENT INSTALLED OUTSIDE THE CONTINENTAL UNITED STATES: Should an in-warranty failure occur, and it is, in the judgment of the Company, impractical to return the equipment for repairs, the Company obligation shall be limited, and the Company shall have the options of either sending a service representative to repair (or supervise the repairs) or granting a reasonable allowance for having the repairs made locally. 22
TrueClean ToteCleaner
TrueClean ToteCleaner Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Check Valve Table of Contents Introduction.... 1 About... 1 Warranty... 2 Safety... 3 Important Safety Information....
More informationTrueClean ToteCleaner
TrueClean ToteCleaner Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Check Valve Table of Contents Introduction.... 1 About... 1 Warranty... 2 Safety... 3 Important Safety Information....
More informationModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.
ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page
More informationInstruction Manual Hydraulic Crimping Tool
Instruction Manual Hydraulic Crimping Tool 902-480 Due to continuing improvements, actual product may differ slightly from the product described herein. Read this material before using this product. Failure
More informationOperator s Manual. Model G32-S Model G32-E Disinfection Soak Stations
Model G32-S Model G32-E Disinfection Soak Stations Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482 Website: WWW.CIVCO.COM Copyright
More informationMax HT Air Heater FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.
Max HT Air Heater FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Safety SHOCK HAZARD! Only qualified individuals should install this heater and related controls. Follow all applicable
More informationOPERATION & INSTALLATION MANUAL
OPERATION & INSTALLATION MANUAL Model: SIO 14 & SIO 18 Electric Tankless Hot Water Generators Table of Contents SAFETY INFORMATION... 1 INTRODUCTION... 2 Unit Operation:... 2 Unit Freezing:... 3 Maintenance:...
More informationMAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE
Wall Heater Fan MODEL #: 2275 This fan is a CSA approved component compatible with these Williams wall heaters only: 1076512.9 2076512.9 3076512.9 1276512 1876512 3076512 1076511.9 2076511.9 IMPORTANT
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS ORIGINAL INSTRUCTIONS MOBILE HUMI-TEMP CABINETS "ETC-1826-HD" SERIES: Non-Insulated 18"x26" Tray Server "ETC-UA-HD" SERIES: Non-Insulated Universal Server P SERIES: Banquet Servers
More informationWrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)
Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series) Instruction Manual Read and understand this material before operating or servicing these heating tapes. Failure to understand how to safely operate
More informationSilicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual
Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual Read and understand this material before operating or servicing these heating tapes. Failure to understand
More informationAir Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com
Read and Save These Instructions Horizon Galaxy - Installation and Operations Manual Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidif iers.com 1 Safety Notes: The Horizon
More informationPortable Induction Ranges
9130, 9130-C 9131-1 9132-1 Portable Induction Ranges INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT INFORMATION READ BEFORE USE It is recommended that maintenance and repairs be conducted by authorized
More informationIon Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm
Ion Endeavor Controller Digital Level Control with Alternation Page 1 of 8 General Overview The Ion Endeavor is a pump controller that senses a water level of up to 72", has a configurable water level/pump
More informationUser s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas
User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5
More informationAUTOMATIC SWINGING DOOR
AAADM American Association of Automatic Door Manufacturers AUTOMATIC SWINGING DOOR OWNER'S MANUAL Distributed by: Contents Section Page Caution 2 To Our Customers 2 Service Availability 3 Compliance with
More informationControl Panel For Water Wash Hoods AM2
Control Panel For Water Wash Hoods AM2 For further information Call: (919) 554-1025 Or Fax: (919)554-1525 Aqua-Matic 117 Franklin Park Ave. Youngsville, NC 27506 TABLE OF CONTENTS AQUA-MATIC LIMITED WARRANTY
More informationCSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models
ASME CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models RETAIN THIS OPERATING MANUAL WITH BOILER. DO NOT DISCARD READ THIS FIRST: The safeguards and instructions
More informationCD6102 / CD6102 OC / CD6102-2
PreView Display CD6102 / CD6102 OC / CD6102-2 Operating Manual www.previewradar.com PATENTS Patented under one or more of the following U.S. Patents: 5345471, 5523760, 5457394, 5465094, 5512834, 5521600,
More informationKD-CLN-LP200 Ultrasonic Vinyl Record Cleaner User s Manual English v1.2 Printed in Korea
TM TM www.klaudio.com KD-CLN-LP200 Ultrasonic Vinyl Record Cleaner User s Manual English v1.2 Printed in Korea s are updated regularly. Please be sure to check our support page for a newer version of this
More informationOPERATION, SERVICE & PARTS MANUAL
OPERATION, SERVICE & PARTS MANUAL BROASTER 620N & 621 EASY BREADER Be sure ALL installers read, understand, and have access to this manual at all times. MODEL 620N MODEL 621 Genuine Broaster Chicken, Broasted,
More informationMODEL HDM-4 AND HDM-6 PERFECT HOLD DELI CASE INSTALLATION/OPERATION MANUAL
An American Tradition Since 1954! MODEL HDM-4 AND HDM-6 PERFECT HOLD DELI CASE INSTALLATION/OPERATION MANUAL Be sure ALL installers read, understand, and have access to this manual at all times. Broaster,
More informationHot Air Tool Air Heaters
Hot Air Tool Air Heaters FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Safety SHOCK HAZARD! Only qualified individuals should install this heater and related controls. Follow all
More informationInstallation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.
Important Information Page 2 Installation and Operation Manual 445 Procedures Cart Installation Page 3 Description Page 5 Components Overview Page 6 Controls & Indicators Page 7 Operation Page 8 HOT Operator
More informationIntroduction... 1 System Overview... 1 System Diagram... 2
TABLE OF CONTENTS Introduction... 1 System Overview... 1 System Diagram... 2 Installation... 3 Console Mounting... 3 Monitor And Power Connections... 3 ASM II Console Main Harness... 4 Module Mounting...
More informationDR Series. Installation & Operations Manual. Model: DR-10 HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR
DR Series HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR Model: DR-10 Installation & Operations Manual 451 Black Forest Road, Hull, Iowa, 51239 712.439.6880 info@ozonesolutions.com www.ozonesolutions.com
More informationIon Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm
Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction
More informationOPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS
Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump Page 1 of 8 biohazard risk exists. Installer(s) and/or service personnel must use proper Personal Protective Equipment and follow handling procedures
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Axor Steel 35807801 Axor Steel Kitchen Faucet 35807801 Max water pressure 145 PSI Recommended water pressure 45-72.5 PSI Recommended hot water temp 120 o - 140 o F*
More informationCHILLER. Model CH3000. Operator s & Installation Manual
CHILLER Model CH3000 Operator s & Installation Manual Release Date: February 14, 2011 Publication Number: 620054173OPR Revision Date: May 08, 2014 Revision: B Visit the Cornelius web site at www.cornelius.com
More information(HSTAT Series) Instruction Manual
Silicone Rubber Heating Tapes with Adjustable Thermostat Control (HSTAT Series) Instruction Manual Read and understand this material before operating or servicing these heating tapes. Failure to understand
More informationTMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control
Installation and Operation Manual Temperature and Pressure Monitoring for Heating and Cooling Applications Temperature Monitoring Control VALVE OPEN ALARM System= 128 o F Alarm At= 130 o F RESET /BACK
More informationOPERATOR S MANUAL. For BURLY ATTACHMENTS
OPERATOR S MANUAL For BURLY ATTACHMENTS April 4, 2018 Clod-Buster Topsoil Screener LIMITED WARRANTY Burly Attachments, LLC warrants to the original Purchaser, all products, manufactured by it, to be free
More informationUser s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access
II User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access Part #2139703 Rev. G II Table of Contents Introduction...3 Elevator Overview...4 Description of Features...5-7
More informationINSTALLATION & OPERATION MANUAL
INSTALLATION & OPERATION MANUAL Model TME- * * Balance of model number is determined by customer specifi ed limits and Setbacks. AUTOMATIC SETBACK THERMOSTAT LIGHT SENSING OR CONTACT CLOSURE FOR LOW VOLTAGE
More informationion Genesis Pump Controller
High Water Alarm Document No.: IONG_OM Page 1 of 7 Table of Contents Safety Precautions.......................... 1 General Overview.......................... 1 Installation.................................2
More informationBEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.
INSTRUCTION MANUAL Model Number: BLZ-SSRF130 BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. 1 TABLE OF CONTENTS REFRIGERATOR SAFETY 3 IMPORTANT SAFEGUIDES 4 PARTS AND FEATURES
More informationIndustrial Vacuums, Inc
Instructions/Spare Parts Manual Nilfisk Model GWD255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in explosion-hazardous areas, as serious injury could result. Under no circumstances
More informationSerpentine II & Serpentine VI Air Heaters
Serpentine II & Serpentine VI Air Heaters FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Safety SHOCK HAZARD! Only qualified individuals should install this heater and related controls.
More informationAutoclave Operations Manual
UNIVERSITY OF ILLINOIS AT URBANA/CHAMPAIGN - COMPOSITES MANUFACTURING LAB Autoclave Operations Manual Version 1 Written by KRH 2/21/2011 Contents ACCS... 4 Alarms... 7 Main Display Tabs... 7 Process Control
More informationUSER S OPERATING AND INSTRUCTION MANUAL
Grand Rapids, Michigan, U.S.A. 49504-5298 USER S OPERATING AND INSTRUCTION MANUAL MODEL 1508-NLG SELF-ACTUATING TRAY LIDDER 1508S20000CV2 INDEX SAFETY INSTRUCTIONS... 1508S20002 SET UP... 1508S20003 OPERATING
More informationCH750, CH751 & CH951 CHILLERS
CH750, CH751 & CH951 CHILLERS Operator s & Installation Manual Release Date: April 19, 2002 Publication Number: 91256 Revision Date: March 25, 2014 Revision: F Visit the Cornelius web site at www.cornelius.com
More informationINSTRUCTION MANUAL P Heating and 1 Cooling
REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1200 2 Heating and 1 Cooling Physical Dimensions Case:
More informationSPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax
SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15 THIS PAGE INTENTIONALLY LEFT BLANK. 2 Operating Instructions and Parts
More informationInstallation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.
Important Information Page 2 Installation and Operation Manual 445 Procedures Cart Installation Page 3 Description Page 5 Components Overview Page 6 Controls & Indicators Page 7 Operation Page 8 HOT Operator
More informationIMpORTANT SAFETy INSTRUcTIONS
Table of contents SAFETy SETUp OpERATION MAINTENANcE Safety... 2 Specifications... 4 Setup... 4 Operation... 6 WARNING SyMBOLS AND DEFINITIONS Maintenance... 9 Parts List and Diagram... 10 Warranty...
More informationSAVE THESE INSTRUCTIONS
U S E R M A N U A L Models: PM15F (shown) PM15P SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: 610-262-6090 Northampton,
More informationInstallation Instructions / Warranty. Starck 10111XX XX XX1
Installation Instructions / Warranty Starck 10111XX1 10120XX1 10211XX1 90502203 1/2005 Starck single control lavatory faucet 10111XX1 Starck tall single control lavatory faucet 10120XX1 Starck single control
More informationINSTRUCTIONS FOR OPERATION AND CARE OF
INSTRUCTIONS FOR OPERATION AND CARE OF LITTLE Splint Compact Splint Pan Model LS-1 Whitehall Manufacturing is a Member of Acorn Engineering s Family of Companies. 6900-191-001 July 2010 Introduction...3
More informationInstallation and Operations Manual
Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement
More informationFOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:
A DIVISION OF FOSTORIA INDUSTRIES, INC. 1200 North Main Street Fostoria, OH 44830-1911 Phone: 800-495-4525 Fax: 419-435-0842 www.fostoriaindustries.com VHC-32 Variable Heat Controller for 222 MUL-T-MOUNT
More informationInstallation Instructions / Warranty. Metris 31060XX XX XX1
Installation Instructions / Warranty Metris 31060XX1 31020XX1 31261XX1 Metris Single Control Lavatory Mixer 31060XX1 Tall Lavatory Mixer 31020XX1 Single Control Bidet Mixer 31261XX1 31060XX1 31020XX1 31261XX1
More informationSCD. SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER Issued March 2015
SCD SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER 21-11-1042 Issued March 2015 Copyright 2015, Galiso, Inc. 22 Ponderosa Ct., Montrose, CO 81401 (970) 249-0233 (800)
More informationUSER MANUAL SAVE THESE INSTRUCTIONS
USER MANUAL Model: PM50 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067
More informationCentral States Industrial. Operation & Maintenance Manual Pilot Plant Direct Steam Injection Vacuum Cool System
Central States Industrial Operation & Maintenance Manual Pilot Plant Direct Steam Injection Vacuum Cool System 1.0 INTRODUCTION 1.1 General 1.2 Safety 1.3 Design and Application 1.4 Receiving and Inspection
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Metris 31063XX1 Metris 31263XX1 Talis 32310XX1 Focus 31730001 Metris Widespread Lavatory Faucet Metris Widespread Bidet Faucet Talis S Widespread Lavatory Faucet Focus
More informationInstallation & Operation Manual
Installation & Operation Manual Radiant Thermostat 519 519_D 06/16 Zoning Replaces: 03/13 Introduction The Radiant Thermostat 519 accurately controls the room and/or floor temperature for a hydronic heating
More informationHumidistat-Thermostat
Humidistat-Thermostat Model # HF _- - - Owner s Manual PNEG-236 Date: 12-02-09 PNEG-236 2 PNEG-236 Humidistat-Thermostat Table of Contents Contents Chapter 1 Safety... 4 Safety Guidelines... 4 Humidistat-Thermostat
More informationEmbedded Linux with VAR-SOM-MX6 Course
VARISCITE LTD. VAR-SOM-MX6 Embedded Linux with VAR-SOM-MX6 Course 2017 Variscite Ltd. All Rights Reserved. No part of this document may be photocopied, reproduced, stored in a retrieval system, or transmitted,
More informationTG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator
TG-10 Wall Mount Installation and Operation Manual High Output Ozone Generator Ozone Solutions 451 Black Forest Road Hull, IA 51239 Phone: (712) 439-6889 Fax: (712) 439-6733 2 Table of Contents Safety
More informationINSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling
INSTRUCTION MANUAL TS21 2 Heating and 1 Cooling WELCOME TO Flexible applications - Universal and easy to install in residential or commercial environments. Advanced features - Precision electronics provide
More informationCarson Manufacturing Co., Inc North Rural Street Indianapolis, IN Phone: (888) Fax: (317)
Carson Manufacturing Co., Inc. 5451 North Rural Street Indianapolis, IN 46220 Phone: (888) 577-6877 Fax: (317) 254-2667 www.carsonsirens.com SC-1012-20 SIREN AMPLIFIER W/ LIGHT CONTROL SC-1012 LT1 LT2
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationUser s Manual and Warranty Information ThyssenKrupp Access
User s Manual and Warranty Information ThyssenKrupp Access Welcome to your Destiny ThyssenKrupp Access would like to thank you for choosing the Destiny. You have purchased one of the finest residential
More informationOperating Instructions. Temperature and Humidity EC Control. Model 35YV93
Operating Instructions EN Temperature and Humidity EC Control Model 35YV93 479702 PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE
More informationCeiling Mount Air Purification System
Ceiling Mount Air Purification System HA-CMP-G2-R/HA-CMP-G2-OV Owner s Manual Table of Contents HealthyAir Series 1219 Filters 1 Important Safety Instructions 2 Technical Specifications 3 Packaging Reference
More information1/24/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.
HOT AIR TOOL 3500 068462, 068463, 068464, 070878, 071383 FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Description! Compact, efficient heater with stainless steel housing and
More informationModel SS2000SS Series ELECTRONIC SIREN AND LIGHT CONTROL SYSTEM (with Slide Switch Control Head)
Model SS2000SS Series ELECTRONIC SIREN AND LIGHT CONTROL SYSTEM (with Slide Switch Control Head) OPERATION AND CONFIGURATION INSTRUCTIONS LIMITED WARRANTY The Signal Division, Federal Signal Corporation
More informationHotPoly Tote Tank / IBC Heaters (TTH Series)
HotPoly Tote Tank / IBC Heaters (TTH Series) Instruction Manual Read and understand this material before operating or servicing these heaters. Failure to understand how to safely operate these heaters
More informationLS-JRE OPERATION & INSTRUCTION MANUAL
SOLVENT RECYCLING SYSTEM LS-JRE OPERATION & INSTRUCTION MANUAL Now with adjustable temperature control! TABLE OF CONTENTS Description Page Introduction 1 Safety Precautions 1 Installation / Set-up 1 Supplied
More informationADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER
Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT
More informationReacti-Therm I and III Heating Modules
INSTRUCTIONS Reacti-Therm I and III Heating Modules TS-18822 TS-18824 Number TS-18822 TS-18824 Description Reacti-Therm I Heating Module (single block) Reacti-Therm III Heating Module (triple block) 2101.1
More informationHIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER
This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER
More informationTG-Series. Installation & Operations Manual. Model: TG-75, TG-150, TG-300, TG-450, TG-600. Water Cooled Ozone Generator
TG-Series Water Cooled Ozone Generator Model: TG-75, TG-150, TG-300, TG-450, TG-600 Installation & Operations Manual 451 Black Forest Road, Hull, Iowa, 51239 712.439.6880 info@ozonesolutions.com www.ozonesolutions.com
More informationELECTRIC FIREPLACE OWNER S MANUAL
ELECTRIC FIREPLACE OWNER S MANUAL MODELS EL1346C 4001358 WARNING: If the information in this manual is not followed exactly, a fire or electrical shock may result causing property damage, personal injury
More informationImportant Safeguards. Save these instructions for future reference. (continued on next page)
User Guide 2. Important Safeguards WARNING To reduce the risk of fire, electric shock or other injury, read and follow the safety precautions and instructions in this User Guide. Save these instructions
More informationOperator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes
Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741
More informationMini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+
Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationInstallation Instructions / Warranty. Hansgrohe Single Control Kitchen Mixers
Installation Instructions / Warranty Hansgrohe Single Control Kitchen Mixers Single-control Kitchen Faucets Models Covered Solaris Stratos Metro Proaktiv* with baseplate 06649XX0 06919XX0 06917XX0 without
More informationINSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700
INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model ABM - 700 M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: 800-831-1525 Mazeppa, MN 55956 Fax : (507)843-4953
More informationOperator's Manual. PCP October 2017
Operator's Manual PCP-0001.2 October 2017 Table of Contents Introduction...4 Intended Use...4 Safety Information...5 Specifications...7 Operating Conditions...7 Lifting and Storing...8 Installation...10
More informationOPERATION, SERVICE & PARTS MANUAL
OPERATION, SERVICE & PARTS MANUAL BROASTER 620NXP & 621 EASY BREADER Be sure ALL installers read, understand, and have access to this manual at all times. MODEL 620NXP MODEL 621 Genuine Broaster Chicken,
More informationAir Pump Up to 800 gallons
Air Pump Up to 800 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PBPAPK40W Questions, problems, missing parts? Before returning to your retailer, call our customer
More informationInstallation & Maintenance Instructions
IMPORTANT INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Saving energy and creating healthy, comfortable environments No. II-450 Date July, 2015 DRIVE-THRU UNIT 3 AIR CURTAIN SERIES DTU03 for outdoor use
More informationNEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL
NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL 456 Creamery Way, Exton, PA 19341, USA Phone: 610.524.8800 Fax: 610.524.8807 Email: info@refrigerantid.com www.refrigerantid.com Page
More informationIMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.
IMPORTANT SAFETY INSTRUCTIONS 2 1. Read and Follow All Instructions 2. Read this manual completely before attempting installation. 3. All permanent electrical connections should be made by a qualified
More informationLaing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual
Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual
More informationQuartz H 2 OT SHOT TM. Infrared Inline Chemical Heater
Quartz H 2 OT SHOT TM Infrared Inline Chemical Heater www.processtechnology.com 7010 Lindsay Dr., Mentor, OH 44060 Phone: 440-974-1300 Fax: 440-974-9561 USA/CN: 800-621-1998 TABLE OF CONTENTS: INTRODUCTION...
More informationDUST FREE CARBON Whole House Air Purifier
DUST FREE CARBON Whole House Air Purifier Installation & Operation Manual This manual covers the following model: DF CARBON 14" - #13052 GENERAL This device is designed to be installed into an existing
More informationIMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
Operating Manual MODEL RC554X AND 554230 ORP Digital Controller FEED ALERT ORP FLOW AUTO MODE SET LEVEL FEED TIME FLOW SWITCH ORP ORP OUTPUT POWER IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS
More informationInstallation, Configuration and User Manual
Model 8826 System Controller Model 8826 System Controller Installation, Configuration and User Manual READ AND SAVE THESE INSTRUCTIONS WELCOME Thank you for choosing the Aprilaire HVAC Automation System.
More informationStatic Pressure Control
The (model SPC-2) is a fully programmable controller that provides extensive flexibility for your curtain or awning control needs. The SPC-2 automatically controls the pressure in a room by operating a
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Citterio M 34133XX1 Citterio M 34213XX1 Axor Citterio M widespread lavatory faucet 34133XX1 Axor Citterio M widespread bidet faucet 34213XX1 34213XX1 34133XX1 Technical
More informationIMPORTANT SAFEGUARDS
IMPORTANT SAFEGUARDS Definitions Whenever used, the following symbol and terms identify safety and property damage messages and designate a level of hazard seriousness. - This is the safety alert symbol.
More informationFigure 1. Figure 2. See notes 1 and 2 below.
273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc. com INSTALLATION INSTRUCTIONS HORN SPEAKER WITH AMPLIFIER Use this product according to this
More informationUse this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30
273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc. com INSTALLATION INSTRUCTIONS HORN SPEAKER WITH MULTI-TAP TRANSFORMER Use this product according
More informationInstruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets
Instruction Manual 36 in. and 42 in. Popcorn Staging Cabinets Model Series 2856 and 2855 42 in. Model 2855-00-000 36 in. Model 2856-00-000 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2016 Gold
More informationSeries: MBC1-TC Mini Benchtop Temperature Controller
User s Guide Series: MBC1-TC Mini Benchtop Temperature Controller Imagine Instruments LLC:: 4500 Williams Drive, Ste 212-318 :: Georgetown, TX 78633 :: p. 855.574.6243 e-mail: info@imagineinstruments.com
More informationModel Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:
Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2
More information