1 OPERATING RANGES Flow rates of up to m /h Manometric heads of up to m Max. operating pressure bar Max. ambient temperature + C Max. loop* temperature * + C Water hardness (TH) F DN ports DN at * à + C for the circulating pump CIRCULATING PUMPS FOR COLLECTIVE APPLICATIONS Domestic hot water Bronze housing poles Hz APPLICATIONS LRL-JRL This circulating pump is only suitable for drinking water. Accelerated circulation in domestic hot water loops. Instant hot water on demand. Collective housing Offices Local authorities Industries Hospitals Hotels, etc. Qm /h BENEFITS Certified Reliable components Motor compartment insulated by a mechanical seal. Motor equipped with an integral (and automatic in -M) ipsothermal sensor Compact size. Easy to install - no alignment problems. Harmless materials in contact with water - maintains water quality. Very quiet operation as all rotating parts and components in contact with water are integrated into the motor cartridge. Choice of operating speeds (dual voltage, three-speed motor in three-phase). Automatic venting. Maintenance-free V -speed selector~ V (accessory) N.T. No -/ENG - Ed. /-

2 DESIGN PRE-SELECTION NOMOGRAPH INSTALLATION PRINCIPLES Hydraulic part - Housing with G pipe unions for - (M) and flanges equipped with pressure taps at the suction and discharge ends for other models. - In-line ports, DN to - PN /. Motor - -pole, -speed motors (except for - M: -pole - speed -Wet runner. - Integral ipsothermal sensor for exterior connection. - Self-lubricating bearings. Rotation speed: see table Winding: Dual voltage with speeds chosen via a plug-in selector connected to the voltage ( V three-phase supplied as standard, V threephase as an option) V single-phase Frequency: Hz Insulation class: H Protection class: IPXD Conformity : CE Immunity EN -- Emission EN Pôles - Hz Poles - Hz SECTIONAL DRAWING Fixing Vis de screw fixation Module Qm /h Ql/min Flooded head Minimum flooded head (in m wc) at the circulating pump intake, according to the operating temperature. + C + c + c DN m m m DN m m m DN m m m DN m m m DN m m m Installation positions Installation diagram Circulating pump on return circuit of the domestic hot water distribution loop. (Max. temperature of circuit = C DTU (French Codes of Practice) standard Heating Heating pump pump Boiler Boiler Hot water Hot water distribution stations points SHW preparation unit Safety Safety set unit Mains supply water water supply SHW DHW system circuit Non Shut-off return valve Non-return valve Check valve Heating return circuit Heating return circuit BASIC CONSTRUCTION Main parts Material Pump housing Bronze Motor shaft X CrMo Impeller PPS Composite Bearings Resin-impregnated carbon IDENTIFICATION : single domestic hot water circulating pump - M Impeller Roue Mechanical Garniture mécanique seal SPEED/VOLTAGE SELECTION Voltage selection A plug-in selector is used to select the voltage: Speed selection The operating speed of the circulating pump is linked to the supply voltage of the motor. The selected speed is shown in the upper window of the terminal box. For -M, the speed is chosen by a rotating selector. ND of ports (mm) HMT (dm) at rated capacity If M: single-phase model Gasket Joint Circlip Motor Moteur Corps Pump de housing pompe ~ V

3 HYDRAULIC PERFORMANCE HYDRAULIC PERFORMANCE -M POLE - DN - POLE - DN - POLE - DN - POLE - DN Qm /h Ql/min Ql/s,, Qm /h Ql/min Ql/s,, Qm /h Ql/min,,,,, Ql/s Qm /h Ql/min Ql/s -M POLE - DN - POLE - DN - POLE - DN Qm /h Ql/min Ql/s,,,, Qm /h Ql/min Ql/s,,,, Qm /h Ql/min Ql/s

4 ELECTRICAL SPECIFICATIONS DIMENSIONAL SPECIFICATIONS FEATURES RÉFÉRENCE ORDER COMMANDE REFERENCE Condensateur Capacitor Selector Position sélecteur position P. Network absorbée Vitesse Speed Puissance Power Intensité Max. current max. power réseau cons. tr/min rpm P max PMin P Max (A) Bloc Motor moteur unit Réf. Ref. μf W W W ~V ~V ~V, BM-M Circulating pump with pipe unions P P a) Electrical - V - Hz single-phase with integral capacitor in the motor. - V or * V ( Hz) three-phase * For ~V, add a speed selector : ref. - sold separately. -M x,,,, -,, BM-N,,, -M x BM-M, H H b) Fitting - Directly onto pipework. - Axis of motor always horizontal. - Connection to the system via round, soldered-on counter-flanges (not supplied). c) Packaging - Models with pipe unions supplied with gaskets but without pipe unions. - Flange models: supplied with bolts, without gaskets or counter-flanges.,, -,, BM-N,,,, -,, BM-N,,,, Circulating pump with flanges L H H P Pg, Pg d) Maintenance - Complete exchange of the motor unit or assembly. RECOMMENDED ACCESSORIES Protective slave switch for motor. Non-return valve. Shut-off valves. Pressure taps kit. Anti-vibration sleeves. Round, soldered-on counter-flanges. -,, BM-N,,,, -,, BM-N,, L RÉFÉRENCE ORDER orifices Ports L H P L H P Masse COMMANDE REFERENCE ND mm mm mm mm mm mm kg -M G, - G, -M - - -, - P G/ Plug prise gauge mano Differential pressure tap kit Order ref. KIT PRESS or KIT PRESS PN flanges - EN - DN D c g Trous Holes mm mm mm nb x mm x x x x n x Ø DN g c D

5 NOTES

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS OPERATING RANGE Flow rate of up to 7 m /h* Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9C Temperature range -C at 9C Max. ambient temperature +C EEI-Part Priux

More information

High-efficiency circulating pumps Heating Air conditioning 50 Hz

High-efficiency circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE Flow rate of up to m /h Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9 C Temperature range - C at 9 C Max. ambient temperature + C EEI-Part,

More information

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature

More information

SUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L

SUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L operating limits Flow up to: m /h Head up to: m w.g. Liquid temperature range: + to 5 C* Specific gravity of liquid:.5 max. ph of liquid: - Max. immersion depth: m Free passage: Ø mm ND of discharge port:

More information

UP/UPS-B/UPN Hot Water Service Circulators

UP/UPS-B/UPN Hot Water Service Circulators UP/UPS-B/UPN Hot Water Service Circulators Visions & Values It is the Vision of the Company to achieve our Corporate Mission by providing quality and innovative products and services that give our customers

More information

MCV - MCH - MCHZ Multistage pumps

MCV - MCH - MCHZ Multistage pumps MCV - MCH - MCHZ Multistage pumps You can put pressure on them! We offer you a range of reliable high-pressure multistage pumps. It includes a series of horizontal pumps, MCH and a series of vertical pumps,

More information

CombiBloc Close-coupled centrifugal pumps

CombiBloc Close-coupled centrifugal pumps CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular

More information

KUBOTA Double suction volute pump

KUBOTA Double suction volute pump PUMPS CATALOGUE KUBOTA Double suction volute pump DV-L type J series KUBOTA Corporation DOMESTIC OFFICES AND OVERSEAS OFFICE E-Mail:pump@kubota.co.jp http://www.kubota.co.jp/english KUBOTA Double suction

More information

CAP SERIES SEWAGE AND WASTE WATER PUMPS

CAP SERIES SEWAGE AND WASTE WATER PUMPS Part 8 CAP SERIES SEWAGE AND WASTE WATER PUMPS TECHNICAL SPECIFICATIONS : Turbosan CAP series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and

More information

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET Circulator pumps 50/60 Hz 2 Product range 2. Product range UP(S) COMFORT, 50/60 Hz Pump type 24-hour timer Supplied with Dimensions Accessories Data sheet Thermostat Isolating valve

More information

SSA Serie. Features. Model code. Applications. Performance Curves. Operation Conditions. Materials

SSA Serie. Features. Model code. Applications. Performance Curves. Operation Conditions. Materials The SSA series is an All-in-One self-priming silent booster pump, the compact design combined pressure tank, pressure switch, flow switch and full protection controller, moreover, the evolutional flow

More information

CRU 200 and 500 Series Condensate Recovery Units

CRU 200 and 500 Series Condensate Recovery Units Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

MULTISAN Fully automatic sewage and waste water pump

MULTISAN Fully automatic sewage and waste water pump MULTISAN Fully automatic sewage and waste water pump Multisan is suitable for pumping waste water from toilets, bidets, showers and basins from rooms which are below the sewer level, or conditions where

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

TECHNICAL. Series 18. Pump Packages

TECHNICAL. Series 18. Pump Packages TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump

More information

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016 SECTION 23 21 23 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section.

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance HIGH EFFICIENCY CIRCULATORS Represented by Taconova Group AG CATALOGUE 218 EN easyuse greatperformance CONTENTS WELCOME...3 HEATING SYSTEMS ES2 6...4 ES2 7...6 ES2 C A 6...8 ES2 ADAPT 6...1 ES2 ADAPT 7...12

More information

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED DNJ SERIES PUMPS END SUCTION CLOSE COUPLED DNJ SERIES PUMPS These are close coupled with standard JM solids shaft ball bearing motors specially designed for pump applications in accordance with standards

More information

MARLOW PUMPS RECIRCULATION

MARLOW PUMPS RECIRCULATION End suction centrifugal pump line available in both close coupled and frame mounted configurations allow users to meet exactly most flow conditions on commercial pool and waterpark applications. Features

More information

EVMSU - Vertical Multistage Pumps. Product Catalog

EVMSU - Vertical Multistage Pumps. Product Catalog EVMSU - Vertical Multistage Pumps Product Catalog www.pumpsebara.com Built like a Kata a A Katana is a traditional Japanese sword made with distinctive, longstanding expertise started in 300 A.D. Katana

More information

dualarm Vertical In-Line Pumps

dualarm Vertical In-Line Pumps Series 430 & 438 dualarm Vertical In-Line Pumps FILE NO: 43d.1 DATE: Jan. 0, 010 SUPERSEDES: 43d.1 DATE: Sept., 008 Series 430 & 438 Smart pumps for the commercial HVAC market. Armstrong Vertical In-Line

More information

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems. Issued 2006/08/01 Section 15131 Pumps Hydronic Systems Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 01780

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR45-12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122818 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122818/cr-45-12-2-a-f-a-e-hqqe.html

More information

ECONOBOOST EB II & EB III Compact Water Booster

ECONOBOOST EB II & EB III Compact Water Booster ECONOBOOST EB II & EB III Compact Water Booster The Stokvis EB II twin pump & EB III triple pump cold water booster units meet today s need for compact, reliable, high performance equipment with modest

More information

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 Building Services Piping. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

Taco 00 Series Cartridge Circulators

Taco 00 Series Cartridge Circulators Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential

More information

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with two or three CM, CMV or CR pumps 50 Hz Table of contents 1. Product introduction 3 2. Performance range 4 with CM pumps 4 with CMV pumps 4 with CR pumps

More information

Data sheet: Wilo-RainSystem AF Comfort MC 304

Data sheet: Wilo-RainSystem AF Comfort MC 304 Data sheet: Wilo-RainSystem AF Comfort MC 304 Pump curves Wilo-RainSystem AF Comfort H/m 50 Wilo-RainSystem AF Comfort Approved fluids (other fluids on request) Pure water without settling sediment Rainwater

More information

Solar heating systems

Solar heating systems 03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

568X, 587X, 588X Series

568X, 587X, 588X Series Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate

More information

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump GH End-Suction Centrifugal Pump GH Horizontal end-suction pump for handling water, oils and chemicals in marine, process and general industrial applications. Hydraulic performance extends to 2,500 GPM

More information

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump GH End-Suction Centrifugal Pump GH Horizontal end-suction pump for handling water, oils and chemicals in marine, process and general industrial applications. Hydraulic performance extends to 2,500 GPM

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps Series 0 & FILE NO: d. DATE: June, 00 SUPERSEDES: d. DATE: July, 00 dualarm Vertical In-Line Pumps dualarm Smart pumps for the commercial HVAC market Vertical In-Line pump, the best design for HVAC systems,

More information

Specially Designed Waste Water & Sewage Pumps

Specially Designed Waste Water & Sewage Pumps Specially Designed Waste Water & Sewage Pumps Technical specifications Ebitt SC series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and other

More information

CombiBloc. Close-coupled centrifugal pumps

CombiBloc. Close-coupled centrifugal pumps CombiBloc Close-coupled centrifugal pumps CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of SPX FLOW 's Johnson Pump brand Combi-system,

More information

Wilo IL Vertical Split-Coupled Inline Pumps

Wilo IL Vertical Split-Coupled Inline Pumps Wilo IL Vertical Split-Coupled Inline Pumps Vertical Inline Split-Coupled, Single Stage Pumps March, 2013 Marcos D. Roimicher, Product Manager BS Market Segment, Product Management Department 120-08-002-0313

More information

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS INDEX Ed. 20150422 GENERAL INFORMATION... 2 Before installing... 2 Materials and PED (97/23/CE) Standards... 3 SKID-TYPE DISTRICT HEATING

More information

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve seal Bearing Enclosed Gland packing Sleeve bearing (Lubricant oil) Water cooling jacket Bearing, Stuffing box (81-120 C) seal: External flushing PUMP Suction side JIS10K normal type Discharge side JIS10K

More information

CRN A-F-G-E-HQQE 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN45-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96123118 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/96123118/crn-45-2-2-a-f-g-e-hqqe.html

More information

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ GRUNDFOS DATA BOOKLET CR5-9 A-FGJ-A-E-HQQE 1x2/24 5HZ Grundfos Pump 96537532 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96537532/cr-5-9-a-fgj-a-e-hqqe.html

More information

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256) CombiChem Centrifugal pumps according to ISO 5199 and ISO 2858 / EN 22858 (DIN 225) CombiChem No limits to reliability! CombiChem is Johnson Pump s solution for liquid transport in the chemical industry.

More information

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range

More information

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR32-4 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9612213 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612213/cr-32-4-a-f-a-e-hqqe.html

More information

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR9-1-1 A-F-A-V-HQQV 3x4D 5 HZ Grundfos Pump 9612486 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612486/cr-9-1-1-a-f-a-v-hqqv.html

More information

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR64-1 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123527 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123527/cr-64-1-a-f-a-e-hqqe.html

More information

CR A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR64-2-2 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123528 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123528/cr-64-2-2-a-f-a-e-hqqe.html

More information

Horizontal Split Case Pumps Type U

Horizontal Split Case Pumps Type U Horizontal Split Case Pumps Type U 7.1 7.2 Stage U Type Pumps Features: Axially Split Case Design Range from 20M 3 /Hr to 600M 3 /Hr Two Stage Pump Single Suction Twin Volute Casing Design Closed type

More information

Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS

Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS Wastewater is a demanding process, performance, day in day out. Xylem challenges, providing trusted

More information

Gas 220 Ace Cascade Assembly Manual

Gas 220 Ace Cascade Assembly Manual Gas 220 Ace Cascade Assembly Manual 1 Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before using the product, and keep it in a safe place for later.

More information

TP /4-A-F-A-BQQE 400D 50HZ

TP /4-A-F-A-BQQE 400D 50HZ GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html

More information

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN9-1 A-F-G-V-HQQV 3x4D 5 HZ Grundfos Pump 96124237 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn9/96124237/crn-9-1-a-f-g-v-hqqv.html

More information

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY SECTION 22 11 23.13 DOMESTIC WATER PRESSURE BOOSTING PART 1 - GENERAL 1.1 SUMMARY A. Where utility water pressure cannot adequately meet the pressure requirements of the domestic water systems and where

More information

SL EX.4.51D

SL EX.4.51D GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html

More information

Allcan TM Installation Manual

Allcan TM Installation Manual Allcan TM Installation Manual NOTICE: READ THESE INSTRUCTIONS CAREFULLY. FAILURE TO FOLLOW INSTRUCTIONS VOIDS WARRANTY. Introduction: The PHP Allcan (USA patent pending) is a complete primary/secondary

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

SL S.S.N.51D

SL S.S.N.51D GRUNDFOS DATA BOOKLET SL1.8..265.2.52S.S.N.51D Grundfos Pump 9814549 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/9814549/sl1-8--265-2-52s-s-n-51d.html

More information

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet 3020/3120 Series Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet A Crane Co. Company DEMING PUMPS Introducting Deming 3020/3120 Series End-Suction

More information

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

HTM Circulation Pumps acc. to DIN EN 733 Type NKX HTM Circulation Pumps acc. to DIN EN 733 Type NKX General The new NKX pump line replaces our former heat transfer oil circulation pump type NKL s. The outer dimensions of both pump types are identical

More information

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s PAPANTONATOS P u m p s s e r v ic e & e n g i nee r in g We supply clean water and remove waste water s e w a g e p u m p s submersible pumps The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

RAINWATER FILTERS AND REUSE OF RAINWATER

RAINWATER FILTERS AND REUSE OF RAINWATER RAINWATER FILTERS AND REUSE OF RAINWATER Rainwater filters to install in front of the tank Rainwater filters to install in the tank Rainwater pumps to install in the house Rainwater pumps to install in

More information

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions 6810850/1 IM-P681-07 ST Issue 1 CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

Goulds Large Capacity, Single Stage, Double Suction Pump

Goulds Large Capacity, Single Stage, Double Suction Pump Goulds 3498 Large Capacity, Single Stage, Double Suction Pump 3498 Double Suction Pumps Designed for a Wide Range of Heavy Duty Industrial, Marine and Power Generation Services Capacities to 8,00 m 3 /h

More information

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges 2 The new GT Condenser provides higher efficiencies and low running costs from the Ideal range of pressurised gas boilers. Extracting

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

Wilo Top S Wet Rotor Circulation Pumps. Engineering Specification

Wilo Top S Wet Rotor Circulation Pumps. Engineering Specification Wilo Top S Wet Rotor Circulation Pumps Engineering Specification PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install circulating pumps consistent with the hydronic system s performance and requirements.

More information

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

Commercial, Residential & Institutional Pumps, Tanks, & Accessories Taco International Commercial, Residential & Institutional Pumps, Tanks, & Accessories Taco Catalog # : 300-6.0 Supersedes: 300-3.5 9/11/06 Effective Date: 03/21/07 Printed in USA Pumps FI Frame Mounted

More information

Dirt and Air Separators

Dirt and Air Separators CX Dirt and Air Separators CX Product Overview Dutypoint CX The Dutypoint CX range of separators are designed to automatically remove dirt and air from heating, cooling and process systems, ensuring optimum

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR32--2 A-F-A-E-HQQE 3x/69 5 HZ Grundfos pump 9612212 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/9612212/cr-32--2-a-f-a-e-hqqe.html

More information

Lifting Plants Product Overview

Lifting Plants Product Overview Wilo-DrainLift Con Duty chart (-pole, 5 Hz) 5 Wilo-DrainLift Con Lifting Plants Product Overview Wilo-DrainLift Lifting Plants Condensate lifting plants Removal of condensate, can be used in Condensing

More information

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz Table of contents 1. Product data 3 Introduction 3 Performance range 4 Product range 6 Type key 9 Operating conditions

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

Innovation for a Better & Greener Future

Innovation for a Better & Greener Future Innovation for a Better & Greener Future Comprehensive range of Water Cooled Variable Speed Centrifugal Chillers with Magnetic Bearing Compressors Kirloskar Chillers, a future-focused organisation, has

More information

X1 series Submersible Drainage Pump

X1 series Submersible Drainage Pump X1 series Submersible Drainage Pump 50HZ STAIRS INDUSTRIAL CO., LTD. X1 SERIES - Submersible Pump Model code X1-03 M A - 32 Discharge size A =Float switch S =Vertical level switch M = Single Phase T =

More information

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler MAIN INDEX INDEX 1 VICTRIX PRO 35-55 2 ErP SPECIFICATIONS...5 2 VICTRIX PRO 80-100-120 2 ErP SPECIFICATIONS...6 3 VICTRIX PRO 35-55

More information

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb) CO 2 Vaporising Atmospheric ASCO CO 2 Vaporiser The atmospheric ASCO CO 2 Vaporiser has been developed to drastically reduce CO 2 vaporisation costs. Ambient air, which is available at no cost, is used

More information

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS MODEL 652A MODEL 654A MODEL 652A MODEL 651A MODEL 653A AURORA 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS WWW.AURORAPUMP.COM 2 AURORA 650 Series Single Stage Solids Handling Pumps Capacities to 2000

More information

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals. SECTION 23 21 23 - HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CAST IRON IMPELLER B4JRMBH. TYPE B SINGLE STAGE CENTRIFUGAL PUMP Bearing Frame Mount TABLE I

CAST IRON IMPELLER B4JRMBH. TYPE B SINGLE STAGE CENTRIFUGAL PUMP Bearing Frame Mount TABLE I Page 90. Date January, 004 Supersedes //95 B4JRMBH Packing Construction 3 9 3 8 Volute Impeller B/M No. Rotation Case Impeller Diameter B3 CW H03843 L059 3.50 B33 CCW H03848 L0594 3.50 8 00 095 3 See Supplement

More information

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage. LN series Horizontal Split Case Pumps Double Volute. Single Stage www.sterlingpumps.com.au LN series Sizes: 6 to 42 Capacity to 12,500 m³/h Heads to 190 metres A rugged, single stage, double volute horizontal

More information

Service Data Vickers. Piston Pumps. PVH98/106 Variable Displacement Piston Pump - 11 Design M-2208-S. Revised 05/01/97

Service Data Vickers. Piston Pumps. PVH98/106 Variable Displacement Piston Pump - 11 Design M-2208-S. Revised 05/01/97 Service Data Vickers Piston Pumps PVH98/106 Variable Displacement Piston Pump - 11 Design Revised 05/01/97 M-2208-S Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque

More information

PRODUCT CATALOGUE

PRODUCT CATALOGUE PRODUCT CATALOGUE 010- PROJECT INNOVENS PRO CA 5-115 from 8.9 to 11 (7.6-98.0 cal/h) Wall-hung gas condensing boilers P. PROJECT INNOVENS PRO CA 5-115 CASCADE SYSTES from 80 to 8 (68.8-368 cal/h) Complete

More information

AIR COOLED PACKAGED CHILLER

AIR COOLED PACKAGED CHILLER AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its

More information

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

ECOCIAT. Domestic hot water heat recovery unit. Use. Range Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY FRIENDLY HFC R410A PROTECTION

More information

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM The GH Series The GH is Carver s horizontal, end suction pump series for handling water, oils, and chemicals in marine, process, and general

More information

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological Providing the comfort of instant hot water is the key requirement of any modern hot water system. The Raychem single-pipe system keeps water at the right temperature in a building s water distribution

More information

Full-line Product Overview

Full-line Product Overview Full-line Product Overview End Suction Centrifugal Pumps This general purpose pump can be configured in frame-mounted and close-coupled, semi-open and enclosed impeller configurations. They are available

More information

5. CONDENSATE PUMPS/UNITS

5. CONDENSATE PUMPS/UNITS INDEX Condensate Systems/Pumps GENERAL INFORMATION BURKS PARTS I&O MANUALS. CONDENSATE PUMPS/UNITS PUMP TYPES: GV GV6 USA: (937) 778-8947 Canada: (90) 47-6223 International: (937) 61-398 A 7/1 Condensate

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

Wilo Stratos Variable Speed Inline Pumps. Engineering Specification

Wilo Stratos Variable Speed Inline Pumps. Engineering Specification Wilo Stratos Variable Speed Inline Pumps Engineering Specification PART 1 - GENERAL 1.1 WORKED INCLUDED A. Furnish and install circulating pumps consistent with the hydronic system s performance, requirements

More information