Error code 1: AC heater current is measured to be 75% below nominal current

Size: px
Start display at page:

Download "Error code 1: AC heater current is measured to be 75% below nominal current"

Transcription

1 Err code 1: AC heater current is measured to be 75% below nominal current Input supplied at the fridge is stable and included between 210V and 240V AC Input issue Check if the 5A fuse is OK Change the fuse (part ) Check if the heater impedance is crect (in Ohm) Type N90-N97- N98-N100- N104-N109- N112-N115 N145-N150- N175-N180 Min Max the AC heater (see Spare Parts List) 1/

2 Err code 2: DC heater current is measured to be 75% below nominal current Input supplied at the fridge is stable and included between 10.5V and 15.4V DC input issue Check if all the connections are OK Reste the connections Check if the D+ input is included between 10.5V and 15.4V D+ input issue Check if the 20A fuse is OK Change the fuse (part ) Check if the heater impedance is crect (in Ohm) Type N90-N97- N98-N100- N104-N109- N112-N115 N145-N150- N175-N180 Min Max the DC heater (see Spare Parts List) / /1

3 Err code 3: AC heater is ON when it should be OFF Input supplied at the fridge is stable and included between 210V and 240V AC input issue Err code 4: DC heater is ON when it should be OFF Input supplied at the fridge is stable and included between 9.5V and 15.5V Check if the D+ input is included between 9.5V and 15.5V and if polarity is crect DC input issue D+ input issue 1/ /6.304

4 Err code 5: Senses flame when gas should be OFF Check if the gas valve wks the gas valve Err code 6: Senses gas output terminal ON when should be OFF : - - part Err code 7: Senses gas output terminal OFF when should be ON : - - part /6.306/ /1

5 Err code 8: AC mains supply is below 20% nominal Input supplied at the fridge is stable and included between 210V and 240V Check if the 5A glass fuse is OK AC input issue Change the fuse (part ) 1/

6 Err code 9: Gas lockout because flame fails to ignite after 30 seconds Check if there is gas to the fridge Ensure there is gas in the cylinder & that it is turned on along with all isolation taps Check if the gas lights Check if there is a spark Check if the spark continues Check if the electrode gap is set at about 4 mm above the burner Adjust the electrode gap to approx. 4 mm Check electrode connections & look f damages electrode Inject of the burner is clean. Flame is dense and blue. Check if the gas pressure is between 28 and 30 mb Check the gas installation Check if the gas valves opens the gas valve Clean the burner and the inject. the burner in case of bad combustion (see Spare Parts List) /1

7 Err code 10: engine running signal is present and control is in Manual DC mode To know if D+ polarity is good, select manually DC mode engine off. If no err code occurs, that means the D+ input is versed. Ensure power supply is capable to supply crect amperage. Input supplied at the fridge is stable and included between 9.5V and 15.5V Check if the D+ input is included between 9.5V and 15.5V and if polarity is crect Check if the 20A fuse is OK DC input issue D+ input issue Change the fuse (part ) 1/

8 Err code 11: energy source is available and control is on AUTO mode Please make sure that all energy sources are available during the trial Select all the energies manually and check which err codes occur See the description of the other err codes /1

9 Err code 12: Supply voltage DC is out of range (9.5V 15.5V) If DC mode have been selected manually, the refrigerat is not switching automatically on another source of energy when the engine is off Input supplied at the fridge is stable and included between 9.5V and 15.5V If RV is equipped with a solar panel. Disconnect it and check if the refrigerat is OK DC input issue D+ input issue Issue with the solar panel regulat solar panel input can be 100% excluded Check if the 5A fuse is OK Contact Thetfd Solar panel issue Change the fuse (part ) 1/

10 Err code 13: Thermist fails, control automatically switches to backup mode (BOS) Check if thermist is present Insert thermist (part ) Check if the thermist is plugged in crectly Plug in crectly (5th fin from the right) Check if the wiring loom is connected to the power board crectly Connect crectly Check if the pins in the wiring loom plug present and not bent loose Fix pins if possible Check with outside wire harness befe replacing the complete fridge Broken wiring harness inside the fridge issue. the complete fridge, see the replacement fridges overview F the partnumber of a warranty fridge /1

11 Err code 14: Display board and power board lost communication to each other Input supplied at the fridge is stable and included between 9.5V and 15.5V DC input issue Check if the 2A glass fuse is OK Change the fuse (part ) Check if the connections between the boards are OK Reste the connections when not OK replace the display board Contact Thetfd Check with outside wire harness befe replacing the complete fridge Broken wiring harness inside the fridge issue. the complete fridge see the replacement fridges overview F the partnumber of a warranty fridge Broken wiring inside fridge ( do if an N180). complete fridge. If an N180 check connections on underside of fridge and in bottom of do. Try a new do befe replacing complete fridge. 1/

12 Crosion on all Fridges shelves Issue Solution Implementation Spare part nr. Compensation Repair-instruction : Crosion on all shelves : Re-infced coating process to prevent rusting during life time product (7 years) : June 22nd 2007 f all shelves : See spare part list : 5 minutes : not included /1

13 Lack of perfmance; err code On 12 Volts Do the testing of the fridges on the manual mode Check if the input at the DC HC poles of the Power Board is > 13.5V DC input issue Check if the input at the heater connection to the Power Board is > 13V Check if the heater impedance is crect (in Ohm) Type N90-N97- N98-N100- N104-N109- N112-N115 N145-N150- N175-N180 Min Max the DC heater (see Spare Parts List) Check if the DC heater is properly settled Install the DC heater properly Contact Thetfd /3

14 On 230 Volts Do the testing of the fridges on the manual mode Check if the input between the (L) and the (N) at the power board is over 220 Volts AC input issue Check if the input at the heater connection to the Power Board is > 215V Check if the heater impedance is crect (in Ohm) Type N90-N97- N98-N100- N104-N109- N112-N115 N145-N150- N175-N180 Min Max the AC heater (see Spare Parts List) Check if the AC heater is properly settled Install the AC heater properly Contact Thetfd 2/

15 On Gas Do the testing of the fridges on the manual mode Inject of the burner is clean. Flame is dense and blue. Gas pressure is between 28 and 30 mb Check if the thermist is properly fitted on the 5th fin from the right Check if the flame diffuser is in the pipe Check if the burner is set properly in front of the pipe Clean the burner. the burner in case of bad combustion (see Spare Parts List) Install the thermist at the right place Install a flame diffuser (part nr to be made) the refrigerat /3

16 on all LCD fridges Issue Solution : A non replaceable fuse (F5) is blowing on the power boards, caused by wrong signal in circuit (f.i. sht cut). : Re-settable fuse integrated on the power board. Implementation : vember 1st 2007 Spare part nr. : and Compensation Repair-instruction : 30 minutes : See repair instruction part old version Underside of Top Half F5 fuse is at top centre Modified power board with re-settable fuse shown in position 1/

Owner s Manual. For N41X models cu. ft., 2-way or 3-way, refrigerators. For N51X models cu. ft., 2-way or 3-way, refrigerators.

Owner s Manual. For N41X models cu. ft., 2-way or 3-way, refrigerators. For N51X models cu. ft., 2-way or 3-way, refrigerators. Owner s Manual F N41X models 4.5 cu. ft., 2way 3way, refrigerats. F N51X models 5.5 cu. ft., 2way 3way, refrigerats. The model numbers of 3way refrigerats include.3. The model numbers of 2way models do

More information

EUROFLAT SERIES TYPES C... S... M...

EUROFLAT SERIES TYPES C... S... M... EUROFLAT SERIES TYPES C... S... M... AUTOMATIC CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN APPLICATION The electronic systems of this range are suitable to control gas

More information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS Note: This manual may also be used for 6536-871 series heat pumps if the 6535-3209 Replacement

More information

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04 prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2004-28 TSG-SOLO-9/04 Table of Contents INTRODUCTION Page 1 SERVICING TIPS AND INSTRUCTIONS Page 3 CONTROL MODULE DISPLAY -

More information

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series 900 & 9100 Series Service Manual & Parts List for Models 9182 9183 9162 9163 982 983 962 963 Safety Information............... 1 Introduction................... 2 Specifications.................. 3 Operating

More information

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE TROUBLESHOOTING INTEGRATED FURNACE Failure to read and follow all instructions carefully before installing or operating this control, could cause personal injury and/ or property damage. 50A55 INTEGRATED

More information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1-316-832-4357

More information

Q - Series Boiler. Troubleshooting Manual

Q - Series Boiler. Troubleshooting Manual Q - Series Boiler Troubleshooting Manual WARNING There are a number of live tests that are required when fault finding this product. Extreme care should be used at all times to avoid contact with energized

More information

The model numbers of 3-way refrigerators include.3. The model numbers of 2-way refrigerators

The model numbers of 3-way refrigerators include.3. The model numbers of 2-way refrigerators Installation Manual F N62X and N62XXX models: F N64X and N64XXX models: F N64XIM and N64XIMXX models: F N82X and N82XXX models: F N84X and N84XXX models: F N84XIM and N84XIMXX models: 6 cu.ft., 2way, R.V.

More information

Thermo 230 / 231 / 300 / 301 / Troubleshooting

Thermo 230 / 231 / 300 / 301 / Troubleshooting Thermo 230 / 231 / 300 / 301 / 350 5 Troubleshooting 5 Troubleshooting 5.1 General This section describes troubleshooting procedures for the heaters Thermo 230, 231, 300, 301 and 350. CAUTION Troubleshooting

More information

Eclipse Self-Check UV Scanner

Eclipse Self-Check UV Scanner 856 Instruction Manual 10/18/2010 Eclipse Self-Check UV Model 5602-91 Version 1 Introduction The self-check UV is used for continuous gas or oil flames. A mechanical shutter in the scanner closes briefly

More information

EUROBOX SERIES TYPES CM... SM... MM...

EUROBOX SERIES TYPES CM... SM... MM... EUROBOX SERIES TYPES CM... SM... MM... AUTOMATIC GAS BURNER CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN Application This range of electronic gas burner control systems

More information

EUROBOX SERIES TYPES CM...N SM...N MM...N

EUROBOX SERIES TYPES CM...N SM...N MM...N EUROBOX SERIES TYPES CM...N SM...N MM...N AUTOMATIC CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN (MANUAL RESET) DESCRIPTION This series of electronic systems is suitable

More information

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08 prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 11/10/08 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1 SERVICING TIPS AND INSTRUCTIONS Page 3 CONTROL

More information

Intermittent Pilot Ignition (IPI) and Direct Spark Ignition (DSI) Applications with Flame Current Probes

Intermittent Pilot Ignition (IPI) and Direct Spark Ignition (DSI) Applications with Flame Current Probes Application Note Issue Date February 22, 2018 Intermittent Pilot Ignition (IPI) and Direct Spark Ignition (DSI) Applications with Flame Current Probes Application This document is intended to aid the appliance

More information

Test/Function Wrinkle release. Display list of diagnostic codes. Then press Temperature (^) - 13 Key. To sequence thru the diagnostic and help codes.

Test/Function Wrinkle release. Display list of diagnostic codes. Then press Temperature (^) - 13 Key. To sequence thru the diagnostic and help codes. Trouble Shooting! WARNING To avoid risk of electrical shock, personal injury, death, disconnect power to washer befe servicing, unless testing requires it. Troubleshooting Guide Maytag Neptune LED Gas

More information

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Ultra Low NOx PowerVent with Honeywell Electronic Control California Only

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Ultra Low NOx PowerVent with Honeywell Electronic Control California Only Error Code Flash TECHNICAL SERVICE DEPARTMENT Gas Valve Status Flash Code Short flash once every four seconds "Heartbeat", alternates bright/dim One Flash, three second pause Two Flash, three second pause

More information

RV REFRIGERATOR LP-GAS & ELECTRIC

RV REFRIGERATOR LP-GAS & ELECTRIC LITERATURE NUMBER MPD 4003333 RV REFRIGERATOR LP-GAS & ELECTRIC HE-0601, HE-0801 PROTECTED BY US PATENTS PENDING avoid possible injury or death SAFETY ALERT SYMBOLS Safety Symbols alerting you to potential

More information

Installation & Troubleshooting Requirements

Installation & Troubleshooting Requirements Installation & Troubleshooting Requirements Wiring Diagram Operation Sequence Presumptions: Main valve knob should always remain in the ON position Gas is bled to the valve Electrical is properly connected

More information

HIGH OUTPUT. Skin design RANGE

HIGH OUTPUT. Skin design RANGE Light drop design HIGH OUTPUT Skin design RANGE Trim design 1 Product Introduction Product Presence Worlwide 2 Product Presentation Bosch Model Commercial Name: GWHC 27 3 Product Presentation Product Design

More information

XIII Troubleshooting

XIII Troubleshooting XIII Troubleshooting The following pages contain troubleshooting charts for use in diagnosing control problems. To use these charts, go to the box marked Start at the top of the chart on page 34 or 36

More information

User Instructions For TopTronic RS-30

User Instructions For TopTronic RS-30 User Instructions F TopTronic RS-30 430294ENG-Jun02 Hoval Ltd Nthgate Newark Nottinghamshire NG24 1JN Phone 01636 672711 Fax 01636 673532 2 Index 430294ENG-Jun02 Introduction Introduction... 3 Controls...

More information

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

DF400/DF600. Construction Heaters. Installation and Maintenance Manual 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. DF400/DF600 Construction

More information

SAFIRE 1600D, 1800D and 2100D Diesel / fuel oil heaters USAGE, INSTALLATION AND MAINTENANCE

SAFIRE 1600D, 1800D and 2100D Diesel / fuel oil heaters USAGE, INSTALLATION AND MAINTENANCE SAFIRE 1600D, 1800D and 2100D Diesel / fuel oil heaters 1 Heater kit contains : Heater, mounting bracket Fuel hose (3 meters), pump, a fuel tank connection to standard tanks (15, 22, 30 litres) Power supply

More information

USER S INFORMATION MANUAL (2,4)SG13B

USER S INFORMATION MANUAL (2,4)SG13B USER S INFORMATION MANUAL (2,4)SG13B Series Gas Heating/Electric Cooling Package Unit Congratulations......your outdoor heating/cooling package unit is a valuable piece of equipment, designed and manufactured

More information

Model 60200FR Gas Primary Control Data Sheet

Model 60200FR Gas Primary Control Data Sheet Programmable, Microprocessor Based Gas Burner Primary Controls On-Board LCD Screen Easy to Understand Icons for Inputs and Outputs Displays micro-amp Flame reading Display operational information Fault

More information

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Owner s Manual MGD-B SERIES GAS FURNACE

More information

PARTS LIST N3104 N3150 N3141

PARTS LIST N3104 N3150 N3141 PARTS LIST N0 N0 N PART NO. 699 NORCOLD /6/08 CONTROL PANEL - N0 / N0 MODELS Art09 NO. PART # DESCRIPTION N0 N0 690869 DISPLAY BOARD MOUNTING BRACKET 6908 DISPLAY BOARD (SN E00N-E66N,E00P-E6P, E00R-E6R,

More information

24 VAC Intermittent Pilot Gas Ignition Control

24 VAC Intermittent Pilot Gas Ignition Control C610U Universal 24 VAC Intermittent Pilot Gas Ignition Control Issue Date: 08/24/2016 Quick Reference Guide The C610U Universal Intermittent Pilot Gas Ignition Control module replaces many popular flame

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

SAFIRE 2000A FUEL OIL HEATER INSTALLATION, OPERATION AND MAINTENANCE

SAFIRE 2000A FUEL OIL HEATER INSTALLATION, OPERATION AND MAINTENANCE SAFIRE 2000A FUEL OIL HEATER INSTALLATION, OPERATION AND MAINTENANCE You have selected the new generation SAFIRE oil heater as your heating solution. Although our goal is to take into account all problems

More information

Technical

Technical Power Direct Vent No Power or No Blower Motor Nothing happens at all. No blower motor; no sounds. y There iss not a display code for this problem. 1. Check wall plug power with a table lamp. 2. Check that

More information

MICROFLAT SERIES TYPES C.../U T X

MICROFLAT SERIES TYPES C.../U T X MICOFLAT SEIES TYPES C.../U T X AUTOMATIC GAS BUNE CONTOL SYSTEMS FO GAS BUNES AND GAS BUNING APPLIANCES WITH O WITHOUT FAN APPLICATION This range of electronic gas burner control systems is suitable for

More information

Pilot Burner and Direct Spark Ignition (DSI) Applications with Flame Rectification Sensing

Pilot Burner and Direct Spark Ignition (DSI) Applications with Flame Rectification Sensing Application Note Issue Date September 25, 2017 Pilot Burner and Direct Spark Ignition (DSI) Applications with Flame Rectification Sensing Application This document is intended to aid the appliance engineer

More information

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP AXIAL HEATER TROUBLE SHOOTING GUIDE Page 1 July 2009 Table of Contents Frequently Asked Questions... 3 Axial Heater CONTROL (Siemens LME69) Troubleshooting Chart... 4 Axial Heater BURNER Troubleshooting

More information

Proper maintenance of tunnel finisher will prolong its life and enable the equipment to produce the best possible quality.

Proper maintenance of tunnel finisher will prolong its life and enable the equipment to produce the best possible quality. Maintenance Guide Proper maintenance of tunnel finisher will prolong its life and enable the equipment to produce the best possible quality. Daily Maintenance CAUTION: Lock out main panel disconnect according

More information

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13 Dexter Industrial On Premise Dryer Troubleshooting, Fault Codes, And Schematics Starting serial number Dryer Trouble Shooting Symptom Probable Cause Suggested Remedy Tumbler does not turn Drive belts Check

More information

Eclipse 90 UV Scanner Model A Version 1

Eclipse 90 UV Scanner Model A Version 1 85 Instruction Manual 10/14/010 Eclipse 90 UV Model 5600-90A Version 1 C US Introduction This sensor features a high sensitivity ultraviolet (UV) tube for monitoring gas or oil flames that cycle on and

More information

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

UV Scanner. Model Specification. Introduction. 854 Instruction Manual 854 Instruction Manual 10/11/010 UV Model 5600-91 C US Introduction This sensor features a high temperature and high sensitivity ultraviolet (UV) tube for monitoring gas or oil flames in applications that

More information

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces Installation Instructions Horizon Natural Draft Electronic Ignition 3 Sided Gas Fireplaces Natural Draft Electronic Ignition

More information

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use GB122 7210 1300-12/2002 GB(EN) For trade use Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C Please read thoroughly before attempting to diagnose fault List of contents

More information

24 VAC Direct Spark Gas Ignition

24 VAC Direct Spark Gas Ignition Installation Instructions Issue Date March 3, 2017 Quick Reference Guide The Direct Spark Gas Ignition control module is designed for direct burner ignition and supervision. It can be used in new applications

More information

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. The RVA63 controller can be utilized to control the following system configurations via LPB communication. Equipment Required

More information

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use GB122 Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C For trade use Please read thoroughly before attemting to diagnose fault 7217 4900 (03/2010) GB/IE List of contents

More information

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP Receiving Do a quick visual inspection on the truck for any major damage prior to signing the paperwork. Damage should be noted

More information

PDV(S,T) MODEL SERIES AND INDUCED DRAFT (D80T725, D65T625) MODEL SERIES WATER HEATERS WITH HONEYWELL INTEGRATED CONTROL SYSTEM

PDV(S,T) MODEL SERIES AND INDUCED DRAFT (D80T725, D65T625) MODEL SERIES WATER HEATERS WITH HONEYWELL INTEGRATED CONTROL SYSTEM PDV(S,T) MODEL SERIES AD IDUCED DRAFT (D80T725, D65T625) MODEL SERIES WATER HEATERS WITH HOEYWELL ITEGRATED COTROL SYSTEM SERVICE MAUAL Troubleshooting Guide and Instructions for Service (To be performed

More information

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions IFT-RC150 IntelliFire Touch Remote Control Installation Instructions Leave this manual with party responsible for use and operation. 1. Introduction The IFT-RC150 is a wall mounted device that is designed

More information

Settings and Maintenance of the CombinAir

Settings and Maintenance of the CombinAir Atmos CombinAir Settings and Maintenance of the CombinAir Issue 13.8.10 Operation and commissioning: The control unit on the front of the CombinAir is used to adjust the settings during commissioning.

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50A65-843 Universal Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING

More information

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3) www.dometic.com Freightliner Refrigerator Troubleshooting Guide For Before initiating troubleshooting, the following equipment is recommended: Multimeter, 20 gauge (min) wires to use as jumpers, and 12Vdc

More information

Suburban RV FURNACES SERVICE MANUAL

Suburban RV FURNACES SERVICE MANUAL Suburban RV FURNACES SERVICE MANUAL DD-17DSI DD-17DSIW NT-12S/SE NT-16S/SE NT-20S/SE NT-24SP NT-30SP NT-34SP NT-40 P-30S/40 SF-20 SF-25 SF-30 SF-35 SF-42 SF-20F SF-25F SF-30F SF-35F SF-42F SH-35 SH-42

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 50A55-474 & 50A55-571 Integrated Furnace Controls INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE

More information

Part 3 Troubleshooting

Part 3 Troubleshooting Part Troubleshooting What is in this part? This part contains the following chapters: Chapter See page Troubleshooting 2 Error Codes: Hydro-box 7 Error Codes: Outdoor Units Error Codes: System Malfunctions

More information

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION M-4000 JANUARY 29, 200 FIREYE M4RT1 FLAME SAFEGUARD CONTROLS WARNING: Selection of this control for a particular application should be made by a competent professional, licensed by a state or other government

More information

Hot Surface Ignition (HSI) System Booklet

Hot Surface Ignition (HSI) System Booklet Hot Surface Ignition (HSI) System Booklet American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com 010298MFM/abe

More information

DRAFT. Northwest RV Supply. Manual Compliments of. Printed From. Service Manual NOT FOR PUBLIC RELEASE

DRAFT.  Northwest RV Supply. Manual Compliments of. Printed From. Service Manual NOT FOR PUBLIC RELEASE Service Manual Gas/Electric Refrigerators MODELS N500 N510! WARNING DO T install this refrigerator in below deck marine applications. Do not install this refrigerator in fixed indoor cabin or other dwelling

More information

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117 Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50V64-743 Integrated Furnace Control for Furnaces with Variable Fan Speed INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

More information

DOMESTIC HOT WATER Follow operational sequence

DOMESTIC HOT WATER Follow operational sequence DOMESTIC HOT WATER Follow operational sequence Turn Winter/Summer selector to Summer position. The display is switch on. Go to section A Error 110 flashing Error 131 flashing Turn the selector to reset

More information

Technical

Technical NOx 75 & 98 Gallon This technical bulletin applies to the 75 and 98 gallon NOx residential product manufactured for the California market. No Power or No Blower Motor Nothing happens at all. No blower

More information

Service Manual Model 3163

Service Manual Model 3163 Service Manual Model 3163 Contents Important Safety Information.......... 1 Specifications.................. 2 General Information.............. 2 Direct Vent Requirements........... 2 Propane System................

More information

Install guide 8010 ENGLISH. Customer Support: or Visit our webiste Made in China

Install guide 8010 ENGLISH. Customer Support: or Visit our webiste  Made in China Install guide 8010 ENLISH ustomer Suppt: 888-515-2585 Visit our webiste www.ritetemp-thermostats.com Made in hina 1-402-033 Install guide 8010 aution Tools 1 Location To avoid electrical shock and to prevent

More information

395CAV Sizes 045 thru 155 Series H and J

395CAV Sizes 045 thru 155 Series H and J ENERGY-EFFICIENT INDUCED-COMBUSTION DELUXE UPFLOW FURNACE 395CAV Sizes 045 thru 155 Series H and J With a unique approach to induced-combustion design, a 40-in. tall cabinet, 4-pass heat exchanger, an

More information

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator. Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N260.3 - a 2.4 cu. ft., 3-way refrigerator. NORCOLD, Inc. P.O. Box 4248 Sidney, OH 45365-4248 Part No. 619260A (4-98) Table

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 031-01284-000/50A55-241 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

WD7664 / WD7663 Maxon Burner. Ellis Whisper Dryer Installation & Start UP

WD7664 / WD7663 Maxon Burner. Ellis Whisper Dryer Installation & Start UP Title WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Procedure No. Installation & Start UP Procedure Author Chris Giordano Effective 1/23/17 Revision A Submitted By Chris Giordano Supersedes Date Revision

More information

8 cu.ft., 2-way, R.V. refrigerators.

8 cu.ft., 2-way, R.V. refrigerators. Owner s Manual For N61X models: For N81X models: 6 cu.ft., 2-way, R.V. refrigerators. 8 cu.ft., 2-way, R.V. refrigerators. WARNING: Improper installation, adjustment, alteration, service or maintenance

More information

AHE S -12 VDC AHE S - 24 VDC

AHE S -12 VDC AHE S - 24 VDC Owner s Manual Model Numbers AHE-100-02S -12 VDC AHE-200-02S - 24 VDC OWNER S INFORMATION Owner s Name: Address: City: State: Zip Code: CUT HERE AND MAIL IN Telephone: Coach Model: Coach Date of Purchase:

More information

Serial-No. / date. Electric: / May 2007

Serial-No. / date. Electric: / May 2007 CE & UL Version Error messages & Troubleshooting Electric and Gas Combi Model Serial-. / date from thru Electric: ESC 65 72584 / May 27 ESC 62 72584 / May 27 ESC 5 72584 / May 27 ESC 2 72584 / May 27 ESC

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

Gas Flare & Rail Burners Gas Flare & Rail Burners Installation Instructions

Gas Flare & Rail Burners Gas Flare & Rail Burners Installation Instructions Gas Flare & Rail Burners Gas Flare & Rail Burners Installation Instructions Gas Flare Rail Burner (Ash Pan ) Rail Burner (Grate ) OPTION 1 OPTION 2 and 3 Installation to Comply with NZS 5262 / 5261:2003

More information

Figure 10 or Figure 6

Figure 10 or Figure 6 SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-45637-00 and 238-48933-00 (Replaces pg. 32 (238-45637-00) or pg. 28 (238-48933-00) in Wiring Diagram Honeywell A B C VERY HO HO LOW Figure 10 or Figure 6 238-48214-00B

More information

Steam Fundamentals. (in heating & processing applications)

Steam Fundamentals. (in heating & processing applications) Steam Fundamentals (in heating & processing applications) Introduction Common Heat Energy conveyers: Thermal Oil Hot water Steam Electrical Electric Heaters Electrodes (High Current) Steam Fundamentals

More information

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA) R SERIES 35-70 120 VAC Microprocessor-Based Direct Spark Ignition Control F-35-70 November 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings

More information

COMMERCIAL 24 VOLT FLUE DAMPER

COMMERCIAL 24 VOLT FLUE DAMPER COMMERCIAL 24 VOLT FLUE DAMPER SERIES WATER HEATER WITH HOEWELL ITEGRATED COTROL SSTEM Gas Water Heaters SERVICE MAUAL Troubleshooting Guide and Instructions for Service (To be performed OL by qualified

More information

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features Installation Instructions E14QRG Issue Date June 28, 2018 Quick Reference Guide The Direct Spark Gas Ignition control module is designed for direct burner ignition and supervision. It can be used in new

More information

Operating and Installation Instructions for CRAMER COE Gas Cooker

Operating and Installation Instructions for CRAMER COE Gas Cooker Operating and Installation Instructions for CRAMER COE Gas Cooker Models: COE-C COE-CG COE-CGO COE-FULL COE-C-DUFU COE-CG-DUFU COE-CGO-DUFU COE-FULL-DUFU Cooker (4 gas burners) Cooker + grill (4 gas burners)

More information

FIREYE FLAME SCANNERS

FIREYE FLAME SCANNERS SC-103 JUNE 7, 2018 48PT1 (Obsolete) FIREYE S 48PT2 INFRARED: 48PT1, 48PT2 and 48PT2-CEX ROD: 69ND1 For UV Self-Check Scanners use SC-101 For Hazardous Locations or NEMA 4X Scanners use SC-106 For Non

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 50A55-286 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

C Note! LGI16... Burner Controls. Building Technologies

C Note! LGI16... Burner Controls. Building Technologies 7 786 Burner Controls LGI16... Burner controls For use on industrial furnaces For burners in continuous operation Without fan control and air pressure supervision Flame supervision - with QR53... / QR55,

More information

P0032-O2 SENSOR 1/1 HEATER CIRCUIT HIGH

P0032-O2 SENSOR 1/1 HEATER CIRCUIT HIGH 8 - ND - DODGE DAKOTA -.7L MAGNUM V8 P-O SENSOR / HEATER CIRCUIT HIGH S6 K9 BR/DG - LEFT FRONT K99 Z K K9 8 8 BR/TN BK/LB DB/LB BR/DG G8 8 C C C O / O / O RETURN HEATER SIGNAL (UPSTREAM) CONTROL CONTROL

More information

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION R SERIES 35-61 24 VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay F-35-61 August 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge

More information

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data. ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data. The RVA 46 Zone Controller can only be used in conjunction with a RVA47 controlled boiler installation. The RVA46 controller

More information

Typical Mount Height. Combustion Chamber

Typical Mount Height. Combustion Chamber ! WARNING: This heater must be installed and serviced by trained gas installation and service personnel only! Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

Inspection Points Trailers & Fifth Wheels

Inspection Points Trailers & Fifth Wheels Inspection Points Trailers & Fifth Wheels We at RVIS, LLC appreciate your business and look forward to providing you with the professional RV inspection you deserve. So that we may provide you with a thorough

More information

Model Universal Oil Primary Control

Model Universal Oil Primary Control Model 70200 Universal Oil Primary Control Installation and Operating Instructions For Use By Qualified Service Technicians Only Universal Replacement for Carlin, Beckett, Honeywell and ICM Controls On-Board

More information

Troubleshooting and Repair Instructions

Troubleshooting and Repair Instructions L Troubleshooting and Repair Instructions J. Eberspächer GmbH & Co. KG Eberspächerstr. 24 D 73730 Esslingen Telephone (switchboard) (0711) 939-00 Facsimile (0711) 939-0500 www.eberspaecher.com The Troubleshooting

More information

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit A Honeywell Company Gas Burner Safety Control For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit Possible flame detectors: - Ionisation probe - Infrared flicker

More information

FURNACE OPERATION OVERVIEW

FURNACE OPERATION OVERVIEW You ve had a fun day but now it s getting chilly, so you decide to fire up the RV furnace. You flip the thermostat on, set the temperature and wait expectantly, but no heat comes from the outlets. It s

More information

PARTS LIST Series REFRIGERATOR PARTS LIST MODEL NDR1292

PARTS LIST Series REFRIGERATOR PARTS LIST MODEL NDR1292 USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center

More information

INSTRUCTION MANUAL AIR HEATER TYPE HEAT-X

INSTRUCTION MANUAL AIR HEATER TYPE HEAT-X INSTRUCTION MANUAL AIR HEATER TYPE HEAT-X GB 0g THIS DOCUMENT MUST ABSOLUTELY BE READ BEFORE STARTING THE INSTALLATION. INSTRUCT USER AND LEAVE THIS DOCUMENT WITH THE HEATER FOR REFERENCE. Instruction

More information

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-44219-00 (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! You have just purchased one of the finest water heaters on

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X500-2 Low voltage 12v dc Brushed motor E90-803-001-005-01 Rev 4-1 - Contents Technical specifications Technical data...3 Working field...3 Dimensions...4 Head

More information

Model No: Little Devil II (inc ss)

Model No: Little Devil II (inc ss) GAS HEATER Model No: Little Devil II (inc ss) PART NO: 6926020, 6926025 (SS) OPERATION & MAINTENANCE INSTRUCTIONS LS1213 INTRODUCTION Thank you for purchasing this CLARKE Gas Heater. Before attempting

More information

Service Manual Gas/Electric Refrigerators

Service Manual Gas/Electric Refrigerators Service Manual Gas/Electric Refrigerators MODELS N61X/N81X N62X/N82X N64X/N84X N64XIM/N84XIM N64X.3/N84X.3 WARNING DO T install this refrigerator in below deck marine applications. Do not install this

More information

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5 4 ±0.5 12.0 Servicing 12.2 Annual Servicing Inspection (Cont) Flame Sensing 5 ±1 10 ±1 Position Fig. 45 Spark Ignition 5. Remove the clip securing the gas feed pipe to the air/gas venturi. Disconnect the

More information

RATIO:GUARD Model E-1S EC Monitor

RATIO:GUARD Model E-1S EC Monitor EC probe Probe tees Probe retention clips Temperature probe E-1S monitor box UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing

More information

GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES PGF 300, 600, 800, 1200

GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES PGF 300, 600, 800, 1200 Page 1 of 17 GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES PGF 300, 600, 800, 1200 VALIDATE WARRANTY SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION

More information

Give It Gas - operates solely as an ONLINE BUSINESS Tel: (011) Cell: (082)

Give It Gas - operates solely as an ONLINE BUSINESS Tel: (011) Cell: (082) Give It Gas - operates solely as an ONLINE BUSINESS Tel: (011) 646 9439 Cell: (082) 452 4488 Email: penny@giveitgas.co.za www.giveitgas.co.za COLD FACTOR 3-WAY CAMPING FREEZERS (200V/ LP GAS/ 12V) 45 litre

More information

Quickheat 30 weather compensated boiler control

Quickheat 30 weather compensated boiler control Quickheat 0 weather compensated boiler control A compact and sophisticated heating controller The compact KM controller is designed for the control of fan assisted boilers with modulating burners. The

More information