Product Number L4006A1017 L4006A1132 L4006A1967 L4006A2007 L4006B1007 L4006B1155 L4006B1163 3/4 (19) L4006H1004

Size: px
Start display at page:

Download "Product Number L4006A1017 L4006A1132 L4006A1967 L4006A2007 L4006B1007 L4006B1155 L4006B1163 3/4 (19) L4006H1004"

Transcription

1 L4006; L6006 Aquastat Controller Aquastat Controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Totally enclosed Micro Switch snap-acting switches operate on temperature rise to setpoint. Visible control point scale and external adjustment screw permit easy setting. Horizontal or vertical insertion of the sensing element. Direct or well immersion of the sensing element. Models available for strap-on mounting. Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications. TRADELINE models include heat-conductive compound. Select models have wells. Dimensions in inches (millimeters) 5/6 (8) (5) KNOCKOUT FOR /4 (9 ) CONDUIT ON ALL MODELS. SIMILAR KNOCKOUT ON OTTOM FOR HORIZONTAL INSERTION AND REMOTE UL MODELS. Case Dimensions: 5 5/8 in. high x in. wide x /8 in. deep (4 mm high x 5 mm wide x 54 mm deep) ulb Size: /8 in. x 7/8 in. (0 mm x 7 mm) copper Maximum Ambient Temperature: 50 F (66 C) American Gas Association IAS: AGA Certified Canadian Standards Association: Certified: File No. LR959- Underwriters Laboratories, Inc. UL Component Recognized: File No. MP466, Vol. 6, Sec., Guide No. MPR 5-5/8 (6) -7/8 (48) KNOCKOUT FOR /4 (9) CONDUIT ON VERTICAL INSERTION MODELS ONLY (5) /6 -/8 (54) (5) /4 (9) RESET UTTON (L4006E, L4008E ONLY) ELEMENT FOR VERTICAL IMMERSION /6 (8) ELEMENT FOR HORIZONTAL IMMERSION /4 (9) M8957A Product Number L4006A009 L4006A07 L4006A L4006A678 L4006A959 L4006A967 L4006A007 L L L40066 L4006E067 Electrical Ratings (Full Load) (Locked Rotor) (Millivolt) 0 Vac; Vac 0 Vac; 40 Vac 0 40 Vac 0 Vac; 40 Vac 0 Vac; 40 Vac 0 Vac; 40 Vac 0 Vac; 40 Vac L4006E09 L4006E to Vdc to Vdc L4006E7 L4006E5 0 Vac; 0 Vac; L4006H Vac 0 Vac; 40 Vac 0 Vac; to Vdc L6006A0 L6006A45 L6006A44 L6006C08 L6006C Vac 40 Vac Operating Temperature Range Differential Temperature Well Spud Size Capillary Length Product Number Application (F) (C) (F) (C) (inch) (mm) (inch) (mm) L4006A009 High or Low 00 F to 5 F C fixed / in. mm limit 40 F 6 C Fixed NPT NPT L4006A07 L4006A High or Low limit High or Low limit 00 F to 40 F 00 F to 40 F 6 C 6 C 5 F to C to / in. 0 F adj. 7 C adj. NPT 5 F Fixed * TRADELINE models SUPER TRADELINE models C fixed /4 in. NPT mm NPT 9 mm NPT Switching Action Mounting Includes Horizontal or / in. well - 869A / in. 8 mm SPST, contacts break / in. 8 mm SPST, contacts break in. 76 mm SPST, contacts break Horizontal or Horizontal or / in. well - 869A Stop factory-set at 60 F (7 C); /4 in. well - 87A 90 customer.honeywell.com

2 * L4006A678 High or Low limit * L4006A959 High or Low limit * L4006A967 High or Low limit L4006A007 High or Low limit 00 F to 40 F 40 F to 80 F 00 F to 40 F 00 F to 40 F L Circulator 00 F to 40 F * L Circulator 00 F to 40 F L40066 Circulator 00 F to 40 F * L4006E067 High Limit; L4006E09 High Limit; L4006E09 High Limit; L4006E7 High Limit; L4006E5 High Limit; * L4006H004 High Limit; strap-on mounting on well mount. L6006A004 Circulator Control and High Limit or Low Limit L6006A0 Circulator Control and High Limit or Low Limit L6006A45 Circulator Control and High Limit or Low Limit L6006A44 Circulator Control and High Limit or Low Limit * L6006C08 Circulator Control and High Limit or Low Limit L6006C059 Circulator Control and High Limit or Low Limit Operating Temperature Range Product Number Application (F) (C) (F) (C) (inch) (mm) (inch) (mm) 0 F to 70 F 0 F to 70 F 0 F to 70 F 00 F to 40 F 00 F to 00 F 00 F to 40 F 00 F to 40 F 00 F to 40 F 00 F to 40 F 00 F to 40 F 65 F to 00 F 65 F to 00 F 6 C 4 C to 8 C 6 C 6 C 6 C 6 C 6 C 54 C to C 54 C to C 54 C to C 6 C 9 C 6 C 6 C 6 C 6 C 6 C 8 C to 9 C 8 C to 9 C 5 F to 0 F adj. 5 F Fixed C to in. 76 mm SPST, contacts break 7 C adj. C fixed in. 76 mm SPST, contacts break 5 F to C to / in. mm / in. 8 mm SPST, contacts break 0 F adj. 7 C adj. 5 F to C to in. 76 mm SPST, contacts break 0 F adj. 7 C adj. 5 F Fixed * TRADELINE models SUPER TRADELINE models Differential Temperature C fixed / in. mm / in. 8 mm SPST, contacts make 5 F to C to in. 76 mm SPST, contacts make 0 F adj. 7 C adj. 5 F to C to in. 76 mm SPST, contacts make 0 F adj. 7 C adj. Well Spud Size Capillary Length in. 76 mm SPST, contacts break in. 76 mm SPST, contacts break / in. to in. /4 in. - 4 NPT 9 mm - 4 NPT 8 mm to 76 mm SPST, contacts break / in. 8 mm SPST, contacts break in. 76 mm SPST, contacts break / in. 8 mm SPST, contacts break Switching Action Mounting Includes Horizontal or Horizontal or Horizontal or Horizontal Horizontal or Horizontal or Horizontal or Horizontal or Horizontal or Horizontal or Horizontal or Horizontal or Horizontal or 5 F C / in. mm / in. 8 mm SPDT Horizontal or 5 F to C to / in. mm / in. 8 mm SPDT Horizontal or 0 F adj. 7 C adj. Heat-conductive compound; Stop factoryset at 40 F (6 C) Heat-conductive compound Stop factory-set at 40 F (6 C); / in. well - 869A / in. well - 869A Heat-conductive compound; Stop factoryset at 40 F (6 C) Well adapter; Stop factory-set at 50 F ( C); Heat-conductive compound /4 in. well - 870A racket for strap-on mounting; Heatconductive compound; Stop factory-set at 40 F (6 C) / in. well - 869A / in. well - 869A 5 F to C to in. 76 mm SPDT Horizontal Heat-conductive 0 F adj. 7 C adj. compound; Stop factoryset at 40 F (6 C) 5 F to C to in. 76 mm SPDT Horizontal or 0 F adj. 7 C adj. 5 F to C to SPDT Horizontal or 0 F adj. 7 C adj. or Strap-onmounting 5 F to C to SPDT Horizontal or 0 F adj. 7 C adj. Stop factory-set at 00 F (9 C) Stop factory-set at 00 F (9 C) Home Controls Indoor Air Quality Residential Combustion Controls Hydronic Controls Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

3 L4008; L6008 Remote ulb Controller Aquastat Controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Remote temperature sensing element detects and responds rapidly to temperature changes. Totally enclosed Micro Switch snap-acting switch. Visible control point scale and external adjustment screw permit easy setting. Horizontal or vertical mounting of the remote element into boiler, tank, or other container. Case mounts to a vertical surface. Dimensions in inches (millimeters) 4-/6 (06) ALTERNATE POSITION OF SENSING ELEMENT CAPILLARY MOUNTING HOLE FOR /6 IN. (5 MM) SCREW () /64 (5) () Case Dimensions: 5 5/8 in. high x in. wide x /8 in. deep (4 mm high x 5 mm wide x 54 mm deep) ulb Size: /8 in. x 7/8 in. (0 mm x 7 mm) copper Mounting: Horizontal or Maximum Ambient Temperature: 50 F (66 C) Electrical Ratings Full Load: 0 Vac; 40 Vac Locked Rotor: 0 Vac; 40 Vac Millivolt: to Vdc Canadian Standards Association: Certified: File No. LR959- Underwriters Laboratories, Inc. UL Component Recognized: File No. MP466, Vol. 6, Sec., Guide No. MPR 5/6 (4) /8 (0) -/4 () SENSING ELEMENT CAPILLARY ALTERNATE POSITION OF SENSING ELEMENT CAPILLARY M88 Product Number Application Operating Temperature Range L4008A05 High or Low limit 00 F to 40 F L4008A0 High or Low limit 0 F to 70 F L40080 Circulator 00 F to 40 F * L4008E56 High Limit; * L4008E05 High Limit; L4008E High Limit; * L6008A9 Circulator Control and Low Limit L6008A4 Circulator Control and Low Limit Differential Temperature (F) (C) (F) (C) 0 F to 70 F 00 F to 40 F 00 F to 00 F 00 F to 40 F 00 F to 00 F * TRADELINE models SUPER TRADELINE models 6 C 54 C to C 6 C 54 C to C 6 C 6 C 6 C 9 C 5 F to 0 F adj. 5 F to 0 F adj. 5 F to 0 F adj. 5 F to 0 F adj. 5 F to 0 F adj. C to 7 C adj. C to 7 C adj. C to 7 C adj. C to 7 C adj. C to 7 C adj. Capillary Length (inch) Switching Action Includes 66 in. SPST, contacts break 5 / ft (.7 m) capillary 0 in. SPST, contacts break 66 in. SPST, contacts make 66 in. SPST, contacts break 66 in. SPST, contacts break 66 in. SPST, contacts break Stop factory-set at 00 F (9 C); 0 ft (.04 m) capillary 5 / ft (.7 m) capillary 5 / ft (.7 m) capillary; Stop factory-set at 50 F ( C); Heat-conductive compound Stop factory-set at 40 F (6 C) SPDT 66 in. capillary; Stop factory-set at 40 F (6 C) SPDT 66 in. capillary 9 customer.honeywell.com

4 L40 Combination Aquastat and High Limit Controller The L40A, is an immersion-type controller for oil-fired water heaters. The Aquastat Controller senses water temperature and cycles the burner through the oil primary. The high-limit controller breaks the circuit to the burner on a temperature rise past the factory-set setpoint. The L40C is an immersion-type controller for gas systems that provides water temperature regulation. The high-limit controller breaks the circuit to the burner on a temperature rise past the factory-set setpoint. L40A,,C have a sensing element and a high limit sensor with automatic reset. Mounts on a horizontal immersion well in water heater wall. Adjustable temperature setting scale. Fluid-filled element operates SPST, Micro Switch snap-acting switch. Integral, nonadjustable high limit. L40C is an immersion controller for gas systems. L40A, is an immersion controller for oil systems. Dimensions in inches (millimeters) 4-/ (04) KNOCKOUT FOR / INCH CONDUIT (6) -/64 (5) -/6 (0) -/64 () -7/8 (99) -/64 () /4 (9) -/8 (5) -/6 (46) -/6 (68) INSULATION DEPTH -/4 OR 4 (57 OR 0) Case Dimensions: 4 / in. wide x 7/8 in. high x /6 in. deep (04 mm wide x 99 mm high x 68 mm deep.) Operating Temperature Range: 00 F to 40 F stop set at 50 F (Scale marked- Hot-Normal-Warm) ( 6 C stop set at 66 C (Scale marked- Hot-Normal-Warm) Differential Temperature Well Spud Size WELL-CLAMP SCREW /4-4 NPT MAXIMUM INSERTION -/8 OR 5 (86 OR 7) M6806A Electrical Ratings: Full Load: 40 Vac; 0 Vac Locked Rotor: 40 Vac; 0 Vac Underwriters Laboratories, Inc. UL Component Recognized: File No. MP466, Guide No. MPR. Insulation Depth Product Number Application (F) (F) (inch) (mm) (inch) (mm) Switching Action L40A09 High Limit 7 F ± 4 F.9 C ± C /4 in. 9 mm 4 in. 0 mm SPST, contacts break NPT NPT L40A00 High Limit 7 F ± 4 F.9 C ± C /4 in. NPT 9 mm NPT /4 in. 57 mm SPST, contacts break Mounting Mounts on a horizontal immersion well in water heater wall. Mounts on a horizontal immersion well in water heater wall. Home Controls Indoor Air Quality Residential Combustion Controls Hydronic Controls Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

5 L800 Aquastat Controller L800A,, and C are immersion type controllers for regulating and limiting the tank temperature in water heaters. As the water temperature rises past the setpoint, the controller switches off the gas valve. Regulates temperature and provides energy cutoff (ECO) action on a temperature rise past the setpoint. Includes a second sensing element that senses average water temperature to minimize stacking. Fluid-filled element operates Micro Switch SPST snap-acting switch. ECO switch interrupts the thermocouple circuit or main valve before tank reaches 0 F (99 C) maximum temperature. Includes factory-installed immersion well on controller. Internal adjustment screw. Special switch terminal provides three-wire hookup from Aquastat controller to gas valve. Dimensions in inches (millimeters) TANK WALL / OR /4 4 NPT C A A INSULATION DEPTH INSERTION DEPTH C WELL DIAMETER CONTROLLER WELL REMOTE WELL IN. MM IN. MM -/4 57 -/ OR -/ 8 OR /6 7/6 M4746 ulb Size: /8 in. (0 mm) Differential Temperature: Controller: 5 F, fixed. Energy Cutoff Switch: 0 F, fixed. (Controller: C fixed; Energy Cutoff Switch: C fixed.) Temperature Rating (ECO) Energy Cutoff: 90 F Maximum Ambient Temperature: Maximum Tank: 0 F (Maximum Tank: 99 C) Operating Temperature Range: 00 F to 80 F ( 8 C) Electrical Ratings: Millivolt: A maximum at 4 Vac. American Gas Association IAS: Design Certified: Report Number - Underwriters Laboratories, Inc. UL Component Recognized: File No. MP466, Guide No. MPR Capillary Length Insulation Depth Product Number Application (inch) (inch) (mm) L80007 High Limit 4 in. controller well: /4 in. remote well: / or / in. L High Limit 54 in. controller well: /4 in. remote well: / or / in. controller well: 57 mm, remote well: 8 mm or 64 mm controller well: 57 mm, remote well: 8 mm or 64 mm Switching Action Mounting SPST, contacts break on temperature rise. SPST, contacts break on temperature rise. L8008 High Limit 9 in. / in. 8 mm SPST, contacts break on temperature rise. Immersion Well Immersion Well Immersion Well Includes Two zinc plated wells and one well clamp for remote well. 94 customer.honeywell.com

6 L408; L608 Multiple Aquastat Controllers High limit, low limit and/or circulator controllers used to regulate boiler water temperature in gas- or oil-fired hydronic heating systems. An immersion type liquid-filled sensing element actuates two snap switches. One switch operates as a high limit control. The other switch operates as a low limit and/or circulator control, depending on the model. Controller may be mounted in any positioning and needs no leveling. Separate, easy-to-read, calibrated dial and setpoint adjustments for each switch. Differential adjustment on low limit or circulator switch. All adjustments accessible inside front cover. Push-in terminals for quick connecting. Cover Maximum Ambient Temperature: 50 F at switches; 65 F at sensing element (66 C at switches; 9 C at sensing element) Operating Range, High Limit: 0 F to 40 F (54 C to 6 C) Operating Range, Low Limit: 0 F to 0 F (4 C to 04 C) Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Electrical Ratings Ignition: Transformer Load: 60 VA Product Number Application L408A0 High and Low limit L4080 High Limit and Circulator L High Limit and Circulator L High Limit and Circulator * L608A00 High and Low limit * L608A06 High and Low limit Dimensions in inches (millimeters) Controller Differential Temperature * TRADELINE models SUPER TRADELINE models Insulation Depth Single sensing element for easy installation. One SPST and one SPDT snap switches act independently at respective temperature settings. Full Load: 40 Vac; 0 Vac Locked Rotor: 40 Vac; 0 Vac Millivolt: to Vdc Canadian Standards Association: Certified: File No. LR959- Underwriters Laboratories, Inc. UL Listed: File No. MP466, Vol., Sec. 4, Guide No. MPR Well Spud Size (F) (inch) (mm) (inch) High limit: 0 F fixed; low limit: 0-5 F adj. / in. 8 mm /4 in. - 4 NPT SPST: High & Low Limit 0 F fixed in. 76 mm /4 in. - 4 NPT SPST: High Limit & Circulator High limit: 0 F fixed; low limit: 0-5 F adj. / in. 8 mm /4 in. - 4 NPT SPST: High Limit & Circulator Switching Action Mounting Includes Horizontal Horizontal Horizontal 0 F fixed in. 76 mm SPST: High Limit & Circulator Horizontal 0 F fixed in. 76 mm /4 in. - 4 NPT Horizontal in. insertion well. High limit: 0 F fixed; low limit: 0-5 F adj. / in. to 4 in. 8 mm /4 in. - 4 NPT Horizontal Home Controls Indoor Air Quality Residential Combustion Controls Hydronic Controls Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

7 R484D PROTECTORELAY CONTROL JUNCTION OX SS LACK K K ORANGE URNER MOTOR CAD CELL F SOLID STATE SWITCH SAFETY SWITCH HEATER K OIL VALVE IGNITION F WHITE L L (HOT) CIRCULATOR 4V THERMOSTAT 4 R R R W T R T RA89A SWITCHING RELAY L608A JUMPER ADDED POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. TERMINALS ARE TA TERMINALS. M customer.honeywell.com

8 L84 Triple Aquastat Relay Horizontal Voltage: 0 Vac Maximum Ambient Temperature: 50 F at switches, 65 F at sensing element. (66 C at switches, 9 C at sensing element.) Operating Range, High Limit: 0 F to 40 F adj. (54 C to 6 C adj.) Operating Range, Low Limit: 0 F to 0 F adj. (4 C to 04 C adj.) Maximum Operating Pressure: 00 psi on outside of immersion well, 00 psi on capsule if inserted directly. (78 kpa on outside of immersion well, 690 kpa on capsule if inserted directly.) Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Canadian Standards Association: Certified: File No. LR60, Guide No. 400-E-O Underwriters Laboratories, Inc. UL Listed (models with well): File No. MP466, Guide No. MPR; UL Component Recognized (models without well): File No. MP466, Guide No. MPR Product Number L84A007 L84A05 Application Differential Temperature Aquastat Controllers Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service. Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems. Provide multizone control by using a separate circulator and R845 Relay for each zone. Include diaphragm powerhead and Micro Switch assembly that respond to temperature changes in boiler water. Mount directly to boiler. Select models include large transformers and extra terminals for supplying power to low voltage zone valves. Require 4 Vac thermostat with heat anticipator set at 0. A (plus current draw of gas valve on L84E). TRADELINE models include tube of heat conductive compound and range stops. L84A (F) (inch) (mm) High Limit Protection, Low High limit: 0 F fixed; Limit and Circulation Control low limit: 0-5 F adj. High Limit Protection, Low High limit: 0 F fixed; Limit and Circulation Control low limit: 0-5 F adj. * L8409 Triple Aquastat Relay with High limit L84C00 Triple Aquastat Relay with High limit L84C0 High limit: 0 F fixed; low limit: 0-5 F adj. High limit: 0 F fixed; low limit: 0-5 F adj. High Limit Protection, Low High limit: 0 F fixed; Limit and Circulation Control low limit: 0-5 F adj. * L84E06 Triple Aquastat Relay with High limit L84G00 Triple Aquastat Relay with High limit L84L0 Triple Aquastat Relay with High limit * TRADELINE models SUPER TRADELINE models High limit: 0 F fixed; low limit: 0-5 F adj. High limit: 0 F fixed; low limit: 0-5 F adj. High limit: 0 F fixed; low limit: 0-5 F adj. Electrical Ratings burner circulator AFL ALR AFL ALR.7 40 Vac; Vac. 40 Vac; Vac.7 40 Vac; Vac Replacement Parts: L74U00 0 Vac Oil Electronic Aquastat Controller with Enviracom communication and troubleshooting Leds. 40 Vac; Vac L84, Line Voltage: Line Voltage:.7 40 Vac;.7 40 Vac; C, E, G, L Vac; Vac; Vac Vac.7 40 Vac.7 40 Vac Insulation Depth Switching Action Mounting Includes / in. 8 mm Mount in. insertion well. in. 76 mm Mount in. insertion well and ground screw. SPST: High & Mount Low Limit SPST: High & Horizontal Low Limit / in. to 8 mm to 76 Horizontal in. less well. mm less well SPST: High & Low Limit SPST: High & Low Limit SPST: High & Low Limit Mount Mount Horizontal Home Controls Indoor Air Quality Residential Combustion Controls Hydronic Controls Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

9 Dimensions in inches (millimeters) ZONE THERMOSTAT V804F ZONE THERMOSTAT V804F TH TR TH TR TH TR TH TR L84G,L TV T Z G K L (HOT) L K W R LOW LIMIT/ CIRCULATOR K HIGH LIMIT R ZR ZC 4 LINE VOLTAGE OIL URNER RELAY OR GAS VALVE LOW VOLTAGE THERMOSTAT L84A,C G C C T T L (HOT) LINE VOLTAGE CIRCULATOR K L POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. W R LOW LIMIT/ CIRCULATOR ZR K UP TO TWO V804F ZONE VALVES CAN E POWERED WITH L84G,L. ADD ADDITIONAL TRANSFORMER FOR EVERY TWO OR LESS VALVES. CONTROL CASE MUST E CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. ZC 4 IS /4 IN. TA TERMINAL. M795 HIGH K LIMIT LINE VOLTAGE OIL URNER RELAY OR GAS VALVE R C C LINE VOLTAGE CIRCULATOR POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. CONTROL CASE MUST E CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. IS /4 IN. TA TERMINAL. M customer.honeywell.com

10 T K LOW VOLTAGE THERMOSTAT T K K L84 G L (HOT) L TV K LOW VOLTAGE THERMOSTAT T Z L84E K G L (HOT) L Home Controls Indoor Air Quality W R LOW LIMIT/ CIRCULATOR POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. POWERPILE CONTROL CASE MUST E CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. R IS /4 IN. TA TERMINAL. HIGH LIMIT K C C LINE VOLTAGE CIRCULATOR TH TH PP PP MILLIVOLTAGE GAS VALVE M884 W R LOW LIMIT/ CIRCULATOR HIGH LIMIT R LOW VOLTAGE GAS VALVE (eg, VR800) POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. CONTROL CASE MUST E CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. IS /4 IN. TA TERMINAL. K C C LINE VOLTAGE CIRCULATOR TR TH M880 Residential Combustion Controls Hydronic Controls Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

11 L848 Aquastat Relay Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors. High limit opens burner circuit only. Include transformer and accessory terminals for adding a remote low limit controller. Case available for horizontal or vertical mounting. Requires a 4 Vac thermostat with heat anticipator set at 0.A. TRADELINE models include well adapter, tube of heat conductive compound and range stops. Dimensions in inches (millimeters) Anticipator Setting: 0. A Voltage: 0 Vac Frequency: 60 Hz Electrical Connections: Quick-Connect/Screw Maximum Ambient Temperature: 50 F with. A 4 V load; 77 F with.4 A 4 V load (66 C with. A 4 V load; 5 C with.4 A 4 V load) Setpoint Temperature Range: 40 F (6 C) Operating Range, High Limit: 0 F to 40 F (54 C to 6 C) Maximum Operating Pressure: Immersion Well: 55 psi (Immersion Well: 757 kpa) Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Canadian Standards Association: Certified: File No. LR60, Guide No. 400-E-O Underwriters Laboratories, Inc. UL Listed: File No. MP466, Vol., Sec., Guide No. MPR. Electrical Ratings (AFL) (burner AFL) (burner ALR) L848A Line Voltage: Vac;.7 40 Vac L848E to 40 Vac; 0 Vac Low Voltage: 0.8 A 4 Vac; Line Voltage: Vac;.7 40 Vac L848J.7 40 Vac; Vac Line Voltage: 0.5 /4 to Vac; Vdc.7 40 Vac Line Voltage: Vac;.7 40 Vac. 40 Vac; Vac (burner millivolt) (circulator AFL) (circulator ALR) 0.5 /4 to Vdc 0.5 /4 to Vdc.7 40 Vac; Vac.7 40 Vac; Vac.7 40 Vac; Vac. 40 Vac; Vac.7 40 Vac; Vac. 40 Vac; Vac Differential Temperature Capillary Length Insulation Depth Product Number Application (F) (inch) (mm) (inch) (mm) * L848A07 High Limit 8 F fixed 4 / in. 4 mm / in. to in. less well * L848E65 High Limit 5 F fixed 4 / in. 4 mm / in. to in. less well * TRADELINE models SUPER TRADELINE models 8 mm to 76 mm less well 8 mm to 76 mm less well Switching Action Mounting Includes SPST: High Horizontal Limit & Circulator SPST: High Limit & Circulator Mount Molex plug for use with vent damper, includes heatconductive compound. Molex plug for use with vent damper, includes heatconductive compound. 00 customer.honeywell.com

12 Product Number Application (F) (inch) (mm) (inch) (mm) L848E99 High Limit 5 F fixed 4 / in. 4 mm / in. to in. less well * L848J009 Aquastat Relay * TRADELINE models SUPER TRADELINE models D89/M A CALE 4 Differential Temperature Capillary Length Insulation Depth 8 F fixed 4 / in. 4 mm / in. to in. less well. L848E FUSE 8 mm to 76 mm less well 8 mm to 76 mm less well HIGH LIMIT CONTROLLER R TV W T K C Switching Action Mounting Includes SPST: High Limit & Circulator SPST: High Limit & Circulator K Z 4 VAC THERMOSTAT C Mount Horizontal or 50 VA transformer and heat conductive compound. Home Controls Indoor Air Quality Residential Combustion Controls Hydronic Controls 4 5 POLARIZED 4-PRONG MALE MOLEX PLUG AND 4-PRONG FEMALE MATING PLUG ON CALE POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE PLUG-IN THAT JUMPERS PINS AND WHEN USING VENT DAMPER. 6-PRONG FEMALE MOLEX RECEPTALE IN L848E AND 5-PRONG MALE MOLEX PLUG ON CALE AFTER VENT DAMPER IS PLUGGED INTO L848E65, FUSE LOWS WHEN THERMOSTAT FIRST CLOSES. AFTER FUSE LOWS, L848E65 OPERATES ONLY WHEN VENT DAMPER IS CONNECTED. SEE VENT DAMPER PRODUCT SPECIFICATIONS FOR INTERNAL SCHEMATICS. IS /4 IN. TA TERMINAL. L 5 4V GND 4V S8600 K L (HOT) L L M76C CIRCULATOR Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

13 G L L R W L6006 LOW LIMIT CONTROLLER L L HOT G L L T T R T T C C K JUMPER C HIGH LIMIT CIRCULATOR K K 4V THERMOSTAT L848A TO LINE VOLTAGE OIL URNER RELAY OR GAS VALVE C POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE JUMPER WHEN ADDING L6006 LOW LIMIT CONTROLLER. 4 L848A CONTROL CASE MUST E CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. IS /4 IN. TA TERMINAL. 4 R M84A 4 W R L6006 LOW LIMIT CONTROLLER MILLIVOLTAGE POWERPILE GAS VALVE G L L PP PP TH TH 5 LOW VOLTAGE GAS VALVE (eg, VR800) K TP TR TV POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. TP THTR REMOVE Z-W JUMPER IF SERIES 60 LOW LIMIT IS USED. WIRE LOW LIMIT CONTROLLER OR ZONE VALVES AS SHOWN. USE WITH 4V (-) CIRCUIT ONLY. FOR 4V URNER, WIRE - AND USE JUMPER Z-W AND TP-Z. FOR POWERPILE (MILLIVOLTAGE) GAS VALVES, REMOVE JUMPER TP-Z AND WIRE URNER -. JUMPER Z-W REMAINS IN POSITION. Z W T K TV R TH W Z 4V THERMOSTAT T HIGH LIMIT C L R C L G L848J CIRCULATOR 4 L L (HOT) L848J AUTO MANUAL SWITCH C C 5 K 4 CONTROL CASE MUST E CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. 5 IS /4 IN. TA TERMINAL. M79 0 customer.honeywell.com

14 L74U Oil Electronic Aquastat Controller The L74U Oil Electronic Aquastat Controller provides electronic temperature sensing in a UL limit-rated controller with a single sensing probe. The L74U controls the circulator, oil burner and boiler temperature. The L74U replaces the L84A, L84C, L74U, L748A, L748A,C, L74A,C, and L848A Controllers. The Aquastat Controller is intended for use in residential-type applications. The L74U provides status and diagnostic information through an LED display combined with LED lights to enhance the diagnostic process. Dimensions, Approximate: 7 /8 in. high x 4 /4 in. wide x 5/8 in. deep (8 mm high x 09 mm wide x 67 mm deep) Maximum Power Consumption: 000 VA Voltage: 0 Vac Frequency: 60 Hz Maximum Ambient Temperature: 50 F (66 C) Minimum Ambient Temperature: -0 F (-9 C) Operating Range, High Limit: 0 F to 40 F (54 C to 6 C) Operating Range, Low Limit: 0 F to 0 F (4 C to 04 C) Product Number L74R000 Application Oil Aquastat Controller with Outdoor Module Differential Temperature (F) High limit: 5-0 F adj.; low limit: 0-5 F adj. L74U00 Oil Aquastat Controller High limit: 5-0 F adj.; low limit: 0-5 F adj. The L74U is Outdoor Temperature ready, which is enabled when connected to the Outdoor Module and C7089U Outdoor Temperature Sensor. The L74U can also interface with the Domestic Hot Water Module for prioritization of a domestic hot water call for heat. Ideal for indirect tank applications. Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Electrical Ratings (burner AFL): Vac (burner ALR): 44.4 A inrush (circulator AFL): Vac (circulator ALR): 44.4 A inrush Underwriters Laboratories, Inc. Recognized Mounting Well mount, horizontal or vertical position, or flush mounted remote from the well. Well mount, horizontal or vertical position, or flush mounted remote from the well. Includes W875S000 Home Controls Indoor Air Quality Residential Combustion Controls Hydronic Controls Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

15 R88 Combination Protectorelay and Hydronic Heating Controllers Immersion type Aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems. Use in intermittent ignition applications. Capable of zone control with zone valves. Circulator zone control with ZC and ZR terminals on R88D,E,H,J. 8*Flame failure during the running cycle results in a 45 second attempt to restart. If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted. R88D,E,F mount directly on burner; R88H,J mount on 4 x 4 in. junction box and include 5 ft (.5 m) armored capillary with remote sensor. C554A Cadmium Sulfide Flame Detector and a 4 Vac thermostat required. Junction ox Mount Dimensions in inches (millimeters) Anticipator Setting: 0. A Maximum Power Consumption: 9 W Voltage: 0 Vac Frequency: 60 Hz Timing Safety Switch: 45 sec Maximum Ambient Temperature: 50 F at element ( C at element) Operating Range, High Limit: 0 F to 40 F (54 C to 6 C) Operating Range, Low Limit: 0 F to 0 F (4 C to 04 C) Maximum Operating Pressure: 00 psi on immersion well; 00 psi direct immersion. (78 kpa on immersion well; 90 kpa direct immersion.) Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Electrical Ratings (ignition): 60 VA (burner AFL): Vac (burner ALR): 6.4 A inrush Canadian Standards Association: Certified: File No. LR959- Underwriters Laboratories, Inc. UL Listed: File No. listed: MP68, Vol.,4 (R88D,E,F), Vol. 7 (R88H,J), Sec.. 04 customer.honeywell.com

16 Differential Temperature Insulation Depth Product Number (F) (inch) (mm) Mounting Includes * R88D079 High limit: 0 F fixed; / in. 8 mm Mount Auxiliary ZC and ZR terminals may be used to provide circulator zone Low limit/circulator: 0 control through an R845A Switching Relay. Heat-conductive compound F to 5 F adj. and vertical case. * R88D High limit: 0 F fixed; Low limit/circulator: 0 F to 5 F adj. * R88H070 High limit: 0 F fixed; Low limit/circulator: 0 F to 5 F adj. * TRADELINE models SUPER TRADELINE models / in. 8 mm Horizontal Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay. Heat-conductive compound and vertical case. / in. 8 mm Junction box mount Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay. Heat-conductive compound and horizontal case. Home Controls Indoor Air Quality Outdoor The Aqua Outdoor Module, when connected to the C7089U Outdoor Sensor, works with any Aqua enabled Aquastat such as the L74/48 via the EnviraCOM -wire bus to optimize boiler efficiency. The Outdoor Module enables efficiency Aquastat functionality, such as Outdoor Temperature, a oost function, and a Warm Weather Shutdown function to generate average operational savings of up to 5%. Enables oiler Outdoor Temperature Enables Warm Weather Shutdown Enables oost Override Easy push wire terminals that provide a secure lock with no need to screw in wires. Simple low-voltage, 5-wire installation ( EnviraCOM, temperature sensor) EnviraCOM Enabled Residential Combustion Controls Hydronic Controls Dimensions, Approximate:.40 in. high x.85 in. wide x.90 in deep Electrical Ratings: 4 Vac, 60 Hz Single and Multi-function Aquastat Parts Maximum Ambient Temperature: 50 F (66 C) Minimum Ambient Temperature: -0 F (-9 C) Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Product Number Mounting Includes W875S000 Wall Mounted in any orientation C7089U006 Outdoor Sensor, Outdoor Module W875S008 Wall Mounted in any orientation Water Pipe Temperature Sensor, Domestic Hot Water Module Product Number Type Description ulb Diameter (inch) Lead Length (inch) Leadwire Ending Leadwire Temperature Used With 0650 Heat Conductive Grease / oz. Well Assembly 98799Z Sensor Outdoor or Supply sensor with 4 in. lead for AQ475, AQ675 or AQ775 /8 in. 4 in. Strip & Retain 5 C Sensor Sensor Assembly for use with L7XX series of Electronic Aquastats 48 in. Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

17 Well Assemblies Well Assemblies Product Number Description 7A 7AA 7 7E 7L Copper. ulb size: /8 in. x in. (0 mm x 76 mm). Well size: in. (76 mm) insertion, / in. NPT. Includes mounting clamp. Well clamp assembly with clamp capillary 7 () screws and nuts 6056 Copper. ulb size: /8 in. x in. (0 mm x 76 mm). Well size: in. (76 mm) insertion, / in. (8 mm) insulation, /4 in. NPT. Includes mounting clamp. Stainless steel. ulb size: /8 in. x in. (0 mm x 76 mm). Well size: in. (76 mm) insertion, / in. (8 mm) insulation, / in. ( mm) NPT. Includes mounting clamp. Copper. ulb size: /8 in. x in. (0 mm x 76 mm). Well size: in. (76 mm) insertion, in. (76 mm) insulation, / in. NPT. Includes mounting clamp. 7M Copper. ulb size: /8 in. x in. (0 mm x 76 mm). Well size: in. (76 mm) insertion, / in. (8 mm) insulation, /4 in. NPT. Includes mounting clamp. 869A Copper. ulb size: /8 in. x in. (0 mm x 76 mm). Well size: in. (76 mm) insertion, / in. (8 mm) insulation, / in. NPT. 870A Copper. ulb size: /8 in. x in. (0 mm x 76 mm). Well size: in. (76 mm) insertion, / in. (8 mm) insulation, /4 in. NPT. 87A Copper. ulb size: /8 in. x in. (0 mm x 76 mm). Well size: in. (76 mm) insertion, in. (76 mm) insulation, /4 in. NPT. 87A Copper. ulb size: /8 in. x in. (0 mm x 76 mm). Well size: in. (76 mm) insertion, in. (76 mm) insulation, / in. NPT 499AA Copper. ulb size: /8 in. (0 mm). Well size: in. (76 mm) insertion, / in. (8 mm) insulation, /4 in. NPT. Includes set screw with spud for armored capillary with plug. 84/00 ulb size: /8 in. x in. (0 mm x 76 mm). Well size: in. (76 mm) insertion, /4 in. NPT Materials Insertion Length Shell (internal diameter) Spud Thread Size Copper / in. /8 in. / in. x 4 NPT Includes 7 Mounting Clamp 7 Mounting Clamp, Spud Set screw for armored capillary, Plug, and Nut. Copper / in. /8 in. /4 in. x 4 NPT Stainless Steel / in. /8 in. / in. x 4 NPT Copper in. /8 in. / in. x 4 NPT Copper in. /8 in. /4 in. x 4 NPT Copper / in. /8 in. / in. x 4 NPT Copper / in. /8 in. /4 in. x 4 NPT Copper in. /8 in. /4 in. x 4 NPT Copper in. /8 in. / in. NPT Copper / in. /8 in. /4 in. x 4 NPT Zinc plated 4 / in. /4 in. x 4 NPT 7 Mounting Clamp 7 Mounting Clamp 7 Mounting Clamp 7 Mounting Clamp Set screw in spud for armored capillary with plug 06 customer.honeywell.com

18 AQUATROL Zoning System AQ50 Electronic Relay oiler Control Panel for Hydronic Zoning System The AQ50 family of AQUATROL oiler Controls provides simplified, energy-efficient control of single temperature, residential hydronic heating systems. The AQ50 easily converts a single zone heating system into a room-by-room comfort control system, or upgrades a basic, relay-logic zoning system to intelligent Zone of Greatest Demand control for increased energy efficiency with reduced boiler cycling. AQ50 boiler controls can ensure ample supply of hot water for both space heating and priority generation of domestic hot water for bathing, dishes and laundry. Controls up to stages of heat from a single thermostat. Use with AQ000 -wire communicating thermostats, or most dry contact digital thermostats. Zoning Control for up to 4 zones as shipped; can be expanded to a total of 6 zones with AQ55 or AQ57 expansion zoning panels and up to 64 zones when used with AQ54 Add-A-Temp panels. Line or low-voltage output for zoning equipment (pumps or valves). Zone synchronization through Zone or Greatest Demand control. Domestic hot water priority and priority override protection. oiler short cycling protection. oiler post purge. Freeze protection. Pump/valve exercise. oiler shock prevention from cold water returning to boiler. Automated test feature for quick start-up and simplified troubleshooting. Integral 8 VA transformer with self-resetting electronic fuse. Application: oiler control for zoned hydronic systems Dimensions, Approximate: in wide x 8 in. high x /8 in deep ( cm wide x 0. cm high x 8.5 cm deep) Power Supply: 0V/60Hz User Interface (Setting, Programming): (DIP Switches) Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire communicating thermostats and most digital thermostats Zone Module Thermostat input: Low voltage, Class II, -wire polarityinsensitive, digital communicating with power link to AQ000 series thermostat. oiler Heat Post Purge: 0 seconds (sent to DHW tank or Zone of Greatest Demand - selectable) oiler (T-T) Output Rating: 4 Vac, 0.5A, VA DHW Demand Input: External dry contacts connection only Pump/Valve exercise: 0 seconds per weeks of space heating inactivity Auxiliary Pump Output Rating: Dry contact output, 0 Vac/50 Vac 5A, / HP Zone Output Contact Rating: Pumps: 0 Vac/50 Vac, 5A, / HP Valves: 4 Vac, 0.5 A, VA ZR-ZC Contact Rating: 0 to 40 Vac, / HP Sensor Temperature Rating: -58 F to +0 F (-50 C to +0 C) Supply/Return Sensor: Lead Length: 0 ft. (050 mm). 0 kilohm NTC thermistor at 5 C (77 F) ±0.5F (±0.C) up to 500 ft (50 M) using 8 AWG or larger wire Heat Demand (Thermostat R-W) Input: External dry contacts connection only - Communication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital communicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II R-C Output (on transformer): 8 VA, 4 Vac Class II Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight: 4.9 lbs (. kg) Canadian Standards Association: CSA C/US Certified to CSA and UL Standards, File No. LR7600 Home Controls Indoor Air Quality Residential Combustion Controls Hydronic Controls Water Controls uilding Automation Product Number AQ504 AQ5044 Type of Zoning Devices Controlled Zone pumps or -wire valves (line voltage) Zone valves with end switches Number of Zones Controlled oiler Pump Output Rating 4 0 Vac/50 Vac 5A, /HP 4 0 Vac/50 Vac 5A, /HP DHW Pump/ Valve Output Rating 0 Vac/50 Vac 5A, /HP 0 Vac/50 Vac 5A, /HP Replacement Parts AQ5000 boiler control module AQC supply/return/mixed loop sensor AQ0X8 4 Vac 8 VA transformer AQ zone pump expansion module AQ5000 boiler control module AQ zone valve with end switch expansion module AQC supply/return/mixed loop sensor AQ0X8 4 Vac 8 VA transformer Commercial Components Pneumatic Controls Industrial Combustion Controls

19 AQUATROL Zoning System AQ5A Programmable Relay Control Panel for Hydronic Zoning System The AQ5A family of AQUATROL Programmable Relay oiler Controls provides simplified, energy-efficient control of singletemperature, residential hydronic heating systems. The AQ5A easily converts a single zone heating system into a room-by-room comfort control system, or upgrades a basic, relay-logic zoning system to intelligent Zone of Greatest Demand control for increased energy efficiency with reduced boiler cycling. AQ5A boiler controls can ensure ample supply of hot water for both space heating and priority generation of domestic hot water for bathing, dishes and laundry. Use with AQ000 -wire dry contact communicating thermostats and most digital thermostats. 0-0 Vdc modulating output for driving a modulating/condensing boiler. Application: oiler control for zoned hydronic systems Dimensions, Approximate: 6 / in wide x 8 in. high x /8 in deep (4 cm wide x 0. cm high x 8.5 cm deep) Power Supply: 0V/60Hz User Interface (Setting, Programming): (LCD Display and a 7 button Key Pad) (DIP Switches on zoning modules) Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire communicating thermostats and most digital thermostats Zone Module Thermostat input: Low voltage, Class II, -wire polarityinsensitive, digital communicating with power link to AQ000 series thermostat. Setback Program: 7 day, up to setback periods/day. oiler Heat Post Purge: Off, 0 seconds to 0 minutes (factory default is 0 seconds) oiler (T-T) Output Rating: 4 Vac, 0.5A, VA oiler Differential: F to 4F (C to C), or Auto (minimum minutes on time) DHW Demand Input: External dry contacts connection only Pump/Valve exercise: 0 seconds per weeks of space heating inactivity Displays outdoor temperature on all AQ000 Series thermostats when used with an AQC0 outdoor sensor (included). Intuitive programming interface and armchair programming (can be programmed at your desk and taken to the job site "ready-to-install"). Customizable control settings and schedules allow for greater level of control and comfort. Controls up to stages of heat from a single thermostat. Central programming of zone set points and setbacks Zoning Control for up to 4 zones as shipped; can be expanded to a total of 6 zones with AQ55 or AQ57 expansion zoning panels, and up to 64 zones when used with AQ54 Add-a-Temperature panels. Zone synchronization through Zone of Greatest Demand control. Domestic hot water priority and priority override protection. Line or low-voltage output for zoning equipment (pumps or valves). oiler short cycling protection. oiler post purge. Freeze protection. Pump/valve exercise. oiler shock prevention from cold water returning to boiler. Automated test and purge feature for quick start-up and simplified troubleshooting. Integral 8 VA transformer with self resetting electronic fuse. hour power supply (super-capacitor) to retain day and time settings during power outage. Non-volatile EPROM memory retains program settings during power outage. Auxiliary Pump Output Rating: Dry contact output, 0 Vac/50 Vac 5A, / HP Auxiliary Low Voltage Output Rating: 4 Vac, 0.5A, VA Auxiliary (Demand) Input: External dry contacts connection only Zone Output Contact Rating: Pumps: 0 Vac/50 Vac, 5A, / HP Valves: 4 Vac, 0.5 A, VA Sensor Temperature Rating: -58 F to +0 F (-50 C to +0 C) Supply/Return Sensor: Lead Length: 0 ft. (050 mm). 0 kilohm NTC thermistor at 5 C (77 F) ±0.5F (±0.C) up to 500 ft (50 M) using 8 AWG or larger wire Heat Demand (Thermostat R-W) Input: External dry contacts connection only - Communication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital communicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) R-C Output (on transformer): 8 VA, 4 Vac Class II Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight: 5.7 lbs (.6 kg) Canadian Standards Association: CSA C/US Certified to CSA and UL Standards, File No. LR7600 Product Number AQ5A4 AQ5A44 Type of Zoning Devices Controlled Zone pumps or -wire valves (line voltage) Zone valves with end switches Number of Zones Controlled oiler Pump Output Rating 4 0 Vac/50 Vac 5A, /HP 4 0 Vac/50 Vac 5A, /HP DHW Pump/ Valve Output Rating 0 Vac/50 Vac 5A, /HP 0 Vac/50 Vac 5A, /HP Replacement Parts AQ5A00 boiler control module AQC supply/return/mixed loop sensor AQC0 outdoor sensor AQ0X8 4 Vac 8 VA transformer AQ zone pump expansion module AQ5A00 boiler control module AQ zone valve with end switch expansion module AQC supply/return/mixed loop sensor AQC0 outdoor sensor AQ0X8 4 Vac 8 VA transformer 08 customer.honeywell.com

20 AQ5 Electronic oiler Control Panel for Hydronic Zoning System The AQ5 family of AQUATROL oiler Controls provides simplified, energy-efficient outdoor temperature compensated control of single temperature, residential hydronic heating systems. The AQ5 easily converts a single zone heating system into a room-by-room comfort control system, or upgrades a basic, relay-logic zoning system to intelligent Zone of Greatest Demand control with outdoor reset for in-creased energy efficiency with reduced boiler cycling. AQ5 boiler controls can ensure ample supply of hot water for both space heating and priority generation of domestic hot water for bathing, dishes and laundry. Application: oiler reset control for hydronic zoning system Dimensions, Approximate AQ50: in wide x 8 in. high x /8 in deep ( cm wide x 0. cm high x 8.5 cm deep) AQ54 and AQ544: 6 / in wide x 8 in. high x /8 in deep (4 cm wide x 0. cm high x 8.5 cm deep) Power Supply: 0V/60Hz User Interface (Setting, Programming): (LCD Display and a 7 button Key Pad) Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire communicating thermostats and most digital thermostats Setback Program: 7 day, up to setback periods/day. oiler Design Temperature: 80F to 0F (6C to 99C) oiler (Supply) Min. Control Temperature: OFF, 59F to 80F (OFF, 5C to 8C) oiler (Supply) Max. Control Temperature: (OFF, 0F to 5 F) OFF, 49C to 07 C oiler Heat Post Purge: Off, 0 seconds to 0 minutes (factory default is 0 seconds) oiler (T-T) Output Rating: 4 Vac, 0.5A, VA oiler Differential: F to 4F (C to C), or Auto (minimum minutes on time) DHW Demand Input: External dry contacts connection only Outdoor Low Design Control Temperature: -60F to F (-5 C to 0 C) AQUATROL Zoning System Use with AQ000 -wire communicating thermostats (AQ54 and AQ544) or most digital dry contact thermostats (AQ50, AQ54, and AQ544). 0-0 Vdc modulating output for driving a modulating/condensing boiler. Displays outdoor temperature on all AQ000 thermostats when used with an AQC0 outdoor sensor (included). Intuitive programming interface and armchair programming (can be programmed at your desk and taken to the job site "ready-to-install") Customizable control settings and schedules allow for greater level of control and comfort. Central programming of zone set points and setback. Controls up to stages of heat from a single thermostat. Zoning Control for up to four zones as shipped; can be expanded to a total of 6 zones with AQ55 or AQ57 expansion zoning panels, and up to 64 zones by using AQ54 Add-a-Temperature expansion panels. Outdoor temperature compensation (reset), or Load reset based on indoor temperature feedback. Zone synchronization through Zone of Greatest Demand control. Domestic hot water priority and priority override protection. Line or low-voltage output for zoning equipment (pumps or valves). oiler short cycling protection. oiler post purge. Freeze protection. Pump/valve exercise. oiler shock prevention from cold water returning to boiler. Automated test and purge feature for quick start-up and simplified troubleshooting. Integral 8 VA transformer with self resetting electronic fuse. hour power supply (super-capacitor) to retain day and time settings during power outage. Non-volatile EPROM memory retains program settings during power outage. Return Minimum Control Temperature: 80 F to 80 F (7C to 8C) Pump/Valve exercise: 0 seconds per weeks of space heating inactivity Auxiliary Pump Output Rating: Dry contact output, 0 Vac/50 Vac 5A, / HP Auxiliary Low Voltage Output Rating: 4 Vac, 0.5A, VA Auxiliary (Demand) Input: External dry contacts connection only WWSD (Warm Weather Shut Down) Temperature: Off, 5 F to 00 F (Off, C to 8 C) Sensor Temperature Rating: -58 F to +0 F (-50 C to +0 C) Supply/Return Sensor: Lead Length: 0 ft. (050 mm). 0 kilohm NTC thermistor at 5 C (77 F) ±0.5F (±0.C) up to 500 ft (50 M) using 8 AWG or larger wire Heat Demand (Thermostat R-W) Input: External dry contacts connection only - Communication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital communicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) R-C Output (on transformer): 8 VA, 4 Vac Class II Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight AQ50: 4.9 lbs (. kg) AQ54 and AQ544: 5.7 lbs (.6 kg) Canadian Standards Association: CSA C/US Certified to CSA and UL Standards, File No. LR7600 Home Controls Indoor Air Quality Residential Combustion Controls Hydronic Controls Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

21 AQUATROL Zoning System Product Number Type of Zoning Devices Controlled Number of Zones Controlled AQ50 None (Noncommunicating) AQ54 AQ544 Pumps or -wire valves Zone valves with end switches oiler Pump Output Rating 0 Vac/50 Vac 5A, /HP 4 0 Vac/50 Vac 5A, /HP 4 0 Vac/50 Vac 5A, /HP DHW Pump/Valve Output Rating 0 Vac/50 Vac 5A, /HP 0 Vac/50 Vac 5A, /HP 0 Vac/50 Vac 5A, /HP Replacement Parts AQ500 boiler reset module AQC supply/return/mixed loop sensor AQC0 outdoor sensor AQ0X8 4 Vac 8 VA transformer AQ500 boiler reset module AQC supply/return/mixed loop sensor AQC0 outdoor sensor AQ0X8 4 Vac 8 VA transformer AQ zone pump expansion module AQ500 boiler reset module AQ zone valve with end switch expansion module AQC supply/return/mixed loop sensor AQC0 outdoor sensor AQ0X8 4 Vac 8 VA transformer 0 customer.honeywell.com

22 AQUATROL Zoning System AQ5 Universal Injection/Mixing oiler Control Panel for Hydronic Zoning System The AQ5 family of AQUATROL Universal Injection/Mixing oiler Controls provides simplified, energy-efficient outdoor temperature compensated control of single-temperature, residential hydronic heating systems. The AQ5 easily converts a single zone heating system into a room-by-room comfort control system, or upgrades a basic, relay-logic zoning system to intelligent Zone of Greatest Demand control with outdoor reset for increased energy efficiency with reduced boiler cycling. AQ5 boiler controls can ensure ample supply of hot water for both space heating and priority generation of domestic hot water for bathing, dishes and laundry. Application: Controls one boiler and one mixing (either variable speed injection or floating valve mixing) loop in a hydronic zoning system. Dimensions, Approximate: 6 / in wide x 8 in. high x /8 in deep (4 cm wide x 0. cm high x 8.5 cm deep) Power Supply: 0V/60Hz User Interface (Setting, Programming): (LCD Display and a 7 button Key Pad) Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire communicating thermostats and most digital thermostats Zone Module Thermostat input: Low voltage, Class II, -wire polarityinsensitive, digital communicating with power link to AQ000 series thermostat. Setback Program: 7 day, up to setback periods/day. oiler Design Temperature: 80F to 0F (6C to 99C) oiler (Supply) Min. Control Temperature: OFF, 59F to 80F (OFF, 5C to 8C) oiler (Supply) Max. Control Temperature: (OFF, 0F to 5 F) OFF, 49C to 07 C oiler Heat Post Purge: Off, 0 seconds to 0 minutes (factory default is 0 seconds) oiler (T-T) Output Rating: 4 Vac, 0.5A, VA oiler Differential: F to 4F (C to C), or Auto (minimum minutes on time) DHW Demand Input: External dry contacts connection only Outdoor Low Design Control Temperature: -60F to F (-5 C to 0 C) Return Minimum Control Temperature: 80 F to 80 F (7C to 8C) Variable Speed Injection Pump Output: Triac modulated; 0 Vac,.A, /6HP Pump/Valve exercise: 0 seconds per weeks of space heating inactivity Use with AQ000 -wire communicating thermostats or most digital dry contact thermostats. Controls one boiler loop and one mixed temperature loop. Use of variable speed injection pump or motorized mixing valve for mixed temperature loop control. 0-0 Vdc modulating output for driving a modulating/condensing boiler or a modulating mixing valve. Displays of outdoor temperature on all AQ000 thermostats when used with an AQC0 outdoor sensor (included). Intuitive programming interface and armchair programming (can be programmed at your desk and taken to the job site "ready-to-install") Customizable control settings and schedules allow for greater level of control and comfort. Central programming of set points and setback. Controls up to stages of heat from a single thermostat. Zoning Control for up to four zones as shipped; can be expanded to a total of 6 zones with AQ55 or AQ57 expansion zoning panels, and up to 64 zones by using AQ54 Add-a-Temperature expansion panels. Outdoor temperature compensation (reset), or Load reset based on indoor temperature feedback. Zone synchronization through Zone of Greatest Demand control. Domestic hot water priority and priority override protection. Line or low-voltage output for zoning equipment (pumps or valves). oiler short cycling protection. oiler post purge. Freeze protection. Pump/valve exercise. oiler shock prevention from cold water returning to boiler. Automated test and purge feature for quick start-up and simplified troubleshooting. Integral 8 VA transformer with self resetting electronic fuse. 4 hours power supply (super capacitor) to retain day and time settings during power outage. Non-volatile EPROM memory retains program settings during power outage. Secondary Pump Output Rating: 0 Vac 5A, /HP Auxiliary Pump Output Rating: Dry contact output, 0 Vac/50 Vac 5A, / HP Auxiliary Low Voltage Output Rating: 4 Vac, 0.5A, VA Auxiliary (Demand) Input: External dry contacts connection only WWSD (Warm Weather Shut Down) Temperature: Off, 5 F to 00 F (Off, C to 8 C) Zone Output Contact Rating: Pumps: 0 Vac/50 Vac, 5A, / HP Valves: 4 Vac, 0.5 A, VA Sensor Temperature Rating: -58 F to +0 F (-50 C to +0 C) Supply/Return Sensor: Lead Length: 0 ft. (050 mm). 0 kilohm NTC thermistor at 5 C (77 F) ±0.5F (±0.C) up to 500 ft (50 M) using 8 AWG or larger wire Heat Demand (Thermostat R-W) Input: External dry contacts connection only Secondary Loop Mixing (Supply) Design Temp Range: 70 F to 0 F ( C to 99 C) Secondary Loop Mixing (Supply) Max Control Temp Range: 80 F to 0 F (7 C to 99 C) Secondary Loop Return Min Control Temp Range: 80 F to 80 F (7 C to 8 C) Secondary Loop Mixing (Supply) Min Control Temp Range: 5 F to 50 F ( C to 66 C) - Communication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital communicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) R-C Output (on transformer): 8 VA, 4 Vac Class II Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight: 6.0 lbs (.7 kg) Canadian Standards Association: CSA C/US Certified to CSA and UL Standards, File No. LR Home Controls Indoor Air Quality Residential Combustion Controls Hydronic Controls Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

23 AQUATROL Zoning System Product Number AQ54 AQ544 Type of Zoning Devices Controlled Zone pumps or -wire valves (line voltage) Zone valves with end switches Number of Zones Controlled Mixing Valve Floating Output (Com,O,C) 4 4Vac rated dry contacts 4 4Vac rated dry contacts Mixing Valve Modulating Output oiler Pump Output Rating 0-0 Vdc 0 Vac/50 Vac 5A, /HP 0-0 Vdc 0 Vac/50 Vac 5A, /HP DHW Pump/ Valve Output Rating 0 Vac 5A, /HP 0 Vac 5A, /HP Replacement Parts AQ500 universal injection/mixing boiler reset module AQC supply/return/mixed loop sensor AQC0 outdoor sensor AQ0X8 4 Vac 8 VA transformer AQ zone pump expansion module AQ500 universal injection/mixing boiler reset module AQ zone valve with end switch expansion module AQC supply/return/mixed loop sensor AQC0 outdoor sensor AQ0X8 4 Vac 8 VA transformer AQ54 Add-a-Temperature Injection/Mixing Expansion Control Panel for Hydronic Zoning System The AQ54 Add-a-Temperature Expansion Control Panel is used in conjunction with an AQ50, AQ5A, AQ5 or AQ5 Control Panel. It provides one additional loop temperature control capability for the AQ000 control panel it is connected to and expands the total network capacity by up to 6 zones when used with AQ55 and/or AQ57 zoning panels. Application: Expanded zone control and mixed loop temperature control in a hydronic zoning system Mixed loop target temperature is reset by either outdoor temperature or calculated system load based on indoor temperature feedback Mixing is target controlled by a variable speed injection pump or motorized mixing valve Dimensions, Approximate: 9 / in wide x 8 in. high x /8 in. deep (4 cm wide x 0. cm high x 8.5 cm deep) Power Supply: 0V/60Hz Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire communicating thermostats and most digital thermostats Variable Speed Injection Pump Output: Triac modulated; 0 Vac,.A, /6HP Secondary Pump Output Rating: 0 Vac 5A, /HP Auxiliary Pump Output Rating: Dry contact output, 0 Vac/50 Vac 5A, / HP Sensor Temperature Rating: -58 F to +0 F (-50 C to +0 C) Acts as an add-on Control panel to the Main (AQ50, AQ5A, AQ5, AQ5) Control panel. Allows each of the 6 zones connected to it to be assigned to the system's primary or secondary loop. Up to AQ54 panels can be added to a Main (AQ50, AQ5A, AQ5 or AQ5) Control panel. Mixed loop temperature is controlled by a variable speed injection pump or motorized mixing valve connected to the AQ54. Intuitive programming interface and armchair programming (can be programmed at your desk and taken to the job site ready-to-install ) Customizable mixing control settings allow for greater level of control and comfort. Zone synchronization through Zone of Greatest Demand control. Integral 8 VA transformer with self resetting electronic fuse. Secondary Loop Mixing (Supply) Design Temp Range: 70 F to 0 F ( C to 99 C) Secondary Loop Mixing (Supply) Max Control Temp Range: 80 F to 0 F (7 C to 99 C) Secondary Loop Return Min Control Temp Range: 80 F to 80 F (7 C to 8 C) Secondary Loop Mixing (Supply) Min Control Temp Range: 5 F to 50 F ( C to 66 C) - Communication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital communicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) R-C Output (on transformer): 8 VA, 4 Vac Class II Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight:.9 lbs (.8 kg) Canadian Standards Association: CSA C/US Certified to CSA and UL Standards, File No. LR7600 Product Number AQ5400 Mixing Valve Floating Output (Com,O,C) User Interface (Setting, Programming) 4Vac rated dry contacts LCD Display and a button Key Pad Replacement Parts AQ5400 Add-A-Temperature expansion control module; AQC supply/return/mixed loop sensor; AQ0X8 4 Vac 8 VA transformer customer.honeywell.com

24 AQUATROL Zoning System AQ55 and AQ57 Zoning Expansion Panel for Hydronic Zoning System The AQ55 and AQ57 family of AQUATROL Expansion Zoning panels work with AQ000 oiler Control Panels and AQ000 Communicating Thermostats to control up to 4 space heating zones (or 8, for the AQ558 Panel). Can be combined with additional expansion zoning panels and an AQ000 control panel for a total of 6 space heating zones. AQ57 for zoning with zone valves with end switches Auto test function to test zones at system start up. It allows for operator controlled testing of zones; includes pause/restart capability. LED lights for visual diagnostic of zone operation. Allows zoning with either "Normally Open" or "Normally Closed" zone valves. Adjacent zoning panels can operate different zone equipment - one panel may control 4 pumps while another may control 4 zone valves. Easily switch from zone valves to pumps with same zoning module - just flip one DIP switch. Ensure correct voltage is applied to all zone equipment on a panel (0 Vac for pumps, 4 Vac for valves) R-C transformer and - data bus terminal connections (network communication) for easy expansion. Zones can be set to energize a group pump via Aux Out dry contacts on main control panel (AQ50, AQ5A, AQ5, AQ5) or expansion control panel (AQ54). Zone synchronization through Zone of Greatest Demand control. 8 VA Transformer with self resetting electronic fuse. Application: Zoning control for hydronic zoning system Dimensions, Approximate: 9 / in wide x 8 in. high x /8 in. deep (4 cm wide x 0. cm high x 8.5 cm deep) User Interface (Setting, Programming): (DIP Switches) Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire communicating thermostats and most digital thermostats Zone Module Thermostat input: Low voltage, Class II, -wire polarityinsensitive, digital communicating with power link to AQ000 series thermostat. Product Number AQ554 AQ558 Type of Zoning Devices Controlled Zone pumps or -wire valves (line voltage) Zone pumps or -wire valves (line voltage) Zone Output Contact Rating: 0 Vac/50 Vac, 5A, / HP - Communication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital communicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight:. lbs ( kg) Canadian Standards Association: CSA C/US Certified to CSA and UL Standards, File No. LR7600 Number of Weight Zones Controlled (kg) (lb) Replacement Parts 4 kg. lbs AQ zone pump expansion module 8. kg.6 lbs AQ zone pump expansion module AQ574 -wire valve (4 Vac) 4.8 kg.9 lbs AQ0X8 4 Vac 8 VA transformer; AQ zone pump expansion module AQ5744 Zone valves with end switches (4 Vac) 4.8 kg.9 lbs AQ zone valve with end switch expansion module; AQ0X8 4 Vac 8 VA transformer Home Controls Indoor Air Quality Residential Combustion Controls Hydronic Controls Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

25 AQUATROL Zoning System AQ000 Series Replacement Control Modules Dimensions, Approximate AQ5000 and AQ5400: / in wide x / in high x 4 /4 in wide (9 cm wide x 94 cm high x 0.09 cm deep) AQ500, AQ500 and AQ5A00: 7 /8 in wide x / in high x 4 /4 in deep (8 cm wide x 94 cm high x 0.09 cm deep) Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) oiler Heat Post Purge: Off, 0 seconds to 0 minutes (factory default is 0 seconds) oiler (T-T) Output Rating: 4 Vac, 0.5A, VA oiler Differential: F to 4F (C to C), or Auto (minimum minutes on time) DHW Demand Input: External dry contacts connection only Pump/Valve exercise: 0 seconds per weeks of space heating inactivity Slab/Floor Sensor: Heat Demand (Thermostat R-W) Input: External dry contacts connection only - Communication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital communicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight AQ5000: 0.5 lbs (0. kg) AQ5400: 0.7 lbs (0. kg) AQ500, AQ500 and AQ5A00:.0 lbs (0.5 kg Canadian Standards Association: CSA C/US Certified to CSA and UL Standards, File No. LR7600 Product Number Mixing Valve Floating Output (Com,O,C) Mixing Valve Modulating Output User Interface (Setting, Programming) AQ5000 DIP Switches AQ Vdc to boiler LCD Display and a 7 button Key Pad AQ500 4Vac rated dry contacts 0-0 Vdc to boiler or mixing valve LCD Display and a 7 button Key Pad AQ5400 4Vac rated dry contacts 0-0 Vdc to mixing valve LCD Display and a button Key Pad AQ5A Vdc to boiler LCD Display and a 7 button Key Pad AQ000 Series Replacement Zoning Modules Dimensions, Approximate: / in wide x / in high x 4 /4 in deep (9 cm wide x 94 cm high x 0.09 cm deep) Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire communicating thermostats and most digital thermostats Zone Module Thermostat input: Low voltage, Class II, -wire polarityinsensitive, digital communicating with power link to AQ000 series thermostat. Zone Output Contact Rating: 0 Vac/50 Vac, 5A, / HP - Communication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital communicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight: 0.6 lbs (0. kg) Canadian Standards Association: CSA C/US Certified to CSA and UL Standards, File No. LR7600 Product Number Type of Zoning Devices Controlled Number of Zones Controlled User Interface (Setting, Programming) AQ5540 Zone pumps or -wire valves (line voltage) 4 (Non-communicating) DIP Switches AQ5740 Zone valves with end switches 4 (Non-communicating) DIP Switches 4 customer.honeywell.com

26 AQ000 Series Accessories and Replacement Parts Product Number Description AQ0X8 Replacement transformer module for AQ50, AQ5A, AQ5, AQ5, AQ54, AQ57 and AQ574 series control and zoning panels. It can be used to add an additional 8 VA power per transformer to drive high VA devices. AQUATROL Zoning System Home Controls Indoor Air Quality AQD0 AQD5 AQD0 AQC0 Replacement enclosure for AQ5400, AQ554, AQ574, AQ5744, AQ558 panels, Consists of case, cover, and DIN rail for mounting of transformer, control or zoning modules. It can be used to add extra AQ0X8 transformers or hide system wiring and component. Replacement enclosure for AQ504, AQ5044, AQ50 panels. Consists of case, cover, and DIN rail for mounting of transformer, control or zoning modules. It can be used to add extra AQ0X8 transformers or hide system wiring and component. Replacement enclosure for AQ5A4, AQ5A44, AQ54, AQ544, AQ54, and AQ544 panels. Consists of case, cover, and DIN rail for mounting of transformer, control or zoning modules.; It can be used to add extra AQ0X8 transformers or hide system wiring and component. Outdoor Sensor with 0 feet of lead wires and a plastic mounting bracket for use with AQ000 Series Programmable Control Panels. Residential Combustion Controls Hydronic Controls AQC AQC0 Supply/Return/Mixed Loop Pipe Sensor with 0 feet of lead wires for use with AQ000 Series Control Panels. Slab/Floor Sensor of 5 feet lead length. It is sold separately for use with AQ000 Series Thermostats to control floor temperatures of in-floor radiant heating applications. Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

27 AQUATROL Zoning System AQ000TN Non-Programmable Communicating Thermostat The AQ000TN thermostat is used to control the ambient air temperature or floor temperature in hydronic heating applications. It communicates with and is powered by an AQ000 series zoning module to provide zoning control. -wire polarity-insensitive non-programmable network communicating thermostat. Liquid crystal display with user buttons. Outdoor, indoor and floor temperature displays. Floor temperature sensing with minimum and maximum limits (when used with optional AQC0 Slab/Floor Sensor - sold separately) Selectable temporary and permanent backlight. Application: Hydronic single-stage zoning heat Network Zoning: Yes Zones: Single or Multi-zone Dimensions, Approximate:.8 in wide x 4.6 in high x.0 in deep (7 cm wide x cm in high x.5 cm deep) Electrical Connections: Wire-clamp screw terminals Network us: Low voltage, Class II, -wire polarity-insensitive, digital communicating link to AQ000 series zoning modules. User Interface (Programming): LCD Display User Interface (System Configuration): DIP Switches Thermostat Type: -wire Communicating Thermostat Sensor Element: Thermistor Sensors (Floor) Used: 0 kilohm NTC thermistor at 5 C (77 F) ±0.5F (±0.C) up to 500 ft (50 M) using 8 AWG or larger wire, beta=89. Lead Length: 0 ft. (050 mm). Mounting: Mount Color: Premier White Temperature Control Mode Selections: "A" for Ambient Air, "F" for Floor, "AF" for Ambient & Floor. Temperatures Displayed: Indoor, Set Point, Outdoor Temperature Display Interval: ±.0 F (±0.5 C) Floor Sensor Temperature Rating: -58F to 0F (-50C to 0C) Floor Temperature Limit Range (AF Model): 40 F to 00 F (5 C to 8 C) Outdoor Temperature Display Range: -58 F to 49 F (-50C to 65 C) Ambient Temperature Range: F to 58 F (0 C to 70 C) Temperature Range, Storage: -0 F to 0 F (-0 C to 55 C) Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight: 0. lb (0. kg) Setting Temperature Range Differential Temperature Product Number (F) (C) (F) (C) Terminal Designations AQ000TN 40 F to 00 F 5 C to 8 C ± F ±0.5 C TH, TH, Sensor, Sensor Type of Control Provided Proportional Integral (PI) LCD Icons Displayed (Mode) Vacation Mode; Set point; Keypad Lock; Comfort/Unoccupied; Heat On Power Method Powered (4 Vdc) by AQ zoning module 6 customer.honeywell.com

28 AQUATROL Zoning System AQ000TP Programmable Heat/Cool Thermostat The AQ000TP thermostat is used to control the ambient air temperature or floor temperature in hydronic heating applications. It communicates with and is powered by an AQ000 series zoning module to provide zoning control. -wire polarity-insensitive programmable network communicating thermostat Liquid crystal display, with 7 user buttons for programming Floor temperature sensing with minimum and maximum limits (when used with optional AQC0 Slab/Floor Sensor - sold separately) 7-day programmable Single-stage Heating and Cooling Outdoor, indoor, and floor temperature display Selectable temporary and permanent backlit Home Controls Indoor Air Quality Application: Hydronic single-stage zoning, heating and cooling Network Zoning: Yes Zones: Single or Multi-zone Dimensions, Approximate:.0 in. wide x 4.9 in. high x.0 in. deep (7.8 cm wide x.5 cm high.5 cm deep) Electrical Connections: Wire-clamp screw terminals Network us: Low voltage, Class II, -wire polarity-insensitive, digital communicating link to AQ000 series zoning modules. User Interface (Programming): LCD Display and 7 user programming buttons User Interface (System Configuration): DIP Switches Thermostat Type: -wire Communicating Thermostat Sensor Element: Thermistor Sensors (Floor) Used: 0 kilohm NTC thermistor at 5 C (77 F) ±0.5F (±0.C) up to 500 ft (50 M) using 8 AWG or larger wire, beta=89. Lead Length: 0 ft. (050 mm). Product Number (F) (C) (F) (C) AQ000TP Setting Temperature Range 40 F to 00 F 5 C to 8 C Differential Temperature Terminal Designations ± F ±0.5 C TH, TH, Sensor, Sensor Mounting: Mount Color: Premier White Temperature Control Mode Selections: "Air" for Ambient Air, "Floor" for Floor, "Air/Floor" for Ambient & Floor limits Temperatures Displayed: Indoor, Set Point, Outdoor Temperature Display Interval: (±0.5 C) Floor Sensor Temperature Rating: -58F to 0F (-50C to 0C) Floor Temperature Limit Range (Air/Floor Model): 40 F to 00 F (5 C to 8 C) Outdoor Temperature Display Range: -58 F to 49 F (-50C to 65 C) Ambient Temperature Range: F to 58 F (0 C to 70 C) Temperature Range, Storage: -0 F to 0 F (-0 C to 55 C) Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight: 0. lb (0.5 kg) Programmability 7-day programmable Type of Control Provided Proportional Integral (PI) LCD Icons Displayed (Mode) Fan On; Vacation Mode; Cool On; Set point; Keypad Lock; Comfort/Unoccupied; Heat On Power Method Powered (4 Vdc) by AQ zoning module Residential Combustion Controls Hydronic Controls Water Controls uilding Automation Commercial Components Pneumatic Controls Industrial Combustion Controls

Single and Multi-Function Aquastat Controllers

Single and Multi-Function Aquastat Controllers L4006; L6006 Aquastat Controller Aquastat Controllers are iersion type devices for limiting or regulating the of liquids in boilers, storage tanks, and other applications where control is required. Totally

More information

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08 16/05/08 Aquatrol Indoor/Outdoor Control B3 Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature Selectable Warm Weather Shut Down (WWSD)

More information

AQ252 Universal Injection/Mixing Boiler Reset Control Panels

AQ252 Universal Injection/Mixing Boiler Reset Control Panels AQ252 Universal Injection/Mixing Boiler Reset Control Panels FEATURES PRODUCT DATA PRODUCT DESCRIPTION The AQ252 family of AQUATROL Universal Injection/Mixing Boiler Reset Controls provides simplified,

More information

AQ250 Series Hydronic Control Panels

AQ250 Series Hydronic Control Panels AQ50 Series Hydronic Control Panels PRODUCT DATA Need new photo of AQ50 PRODUCT DESCRIPTION The AQ50 easily converts a single-zone heating system into a room-by-room comfort control system, or upgrades

More information

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252 AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252 USER OPERATION AND MAINTENANCE WARNING Risk of electrical shock. Can cause severe injury, property damage or death. Only

More information

R8182D,E,F,H,J Combination Protectorelay Primary Control and Aquastat Controller

R8182D,E,F,H,J Combination Protectorelay Primary Control and Aquastat Controller R88D,E,F,H,J Combination Protectorelay Primary Control and Aquastat Controller APPLICAION he R88 combines a Protectorelay primary control and immersion type Aquastat controller in one unit for use in oil-fired,

More information

AQ255 and AQ257 Series Expansion Zoning Panels

AQ255 and AQ257 Series Expansion Zoning Panels AQ55 and AQ57 Series Expansion Zoning Panels PRODUCT DATA AQ574B AQ558B FEATURES The AQ55/AQ57 Series Expansion Zoning Panels have the following features: Availability of 4 Expansion Zoning Panels. Zone

More information

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control Model 7600 Boiler Control PARTS & ACCESSORIES Features & Benefits Beckett HeatManager TM dynamic temperature reset Cycle history diagnostic information Reduce inventory through universal design Backlit

More information

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A Table of Contents Part Number Index MANUFACTURER Page MANUFACTURER Page 1 1271A 1271B -211-B15 182EA 2 220736B 5 5/8X10RL 5/8X12RL 5/8X18RL 5/8X24RL 5/8X36RL 5/8X48HDRL 5/8X60RL 6 CONBRACO 6012 WHEELER

More information

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules Instruction manual WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules This manual must only be used by a qualified heating installer/service technician.

More information

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers Electronic Pool and Spa Controllers The L8005A,B and LS8005A,C,D Electronic Pool and Spa Controllers are used in pool, spa, and hot tub applications to control water temperature. Remote Potentiometer L8005A,B

More information

- Data Brochure Universal Reset Module 422

- Data Brochure Universal Reset Module 422 - Data Brochure Universal Reset Module 422 D 422 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

Hydronic & HVAC Control Systems

Hydronic & HVAC Control Systems tekmar 218 Full Line Catalog Hydronic & HVAC Control Systems HVAC Multi-Staging Alternative Energy Zoning Snow Melting Setpoint tekmarcontrols.com tekmarcontrols.com Better Design, Better Control, Better

More information

Better Design, Better Control, Better Systems.

Better Design, Better Control, Better Systems. Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning

More information

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC Viega Zone Control Applications The Viega Zone Control is a wiring and switching center for individual and / or multi- room control. The Zone Control simplifies wiring between Thermostats and Powerheads.

More information

Commercial/Industrial Combustion Control Level Three Announcement

Commercial/Industrial Combustion Control Level Three Announcement Commercial/Industrial Combustion Control Level Three Announcement SUBJECT: C6097 requiring venting Model Numbers Affected: C6097A and B Ref. Number L3-08-006 Issue Date 12/9/08 Author P.Yuen/L.Ziller Date

More information

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001 SLATE Burner Control Module R8001B2001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

- Data Brochure Universal Reset Module 423

- Data Brochure Universal Reset Module 423 - Data Brochure Universal Reset Module 423 D 423 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

ProRadiant Controls, Valves and Actuators

ProRadiant Controls, Valves and Actuators 214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Keep these instructions with the boiler at all times. BOYERTOWN FURNACE CO. PO Box 100 BOYERTOWN, PA 19512 1-610-369-1450 www.boyertownfurnace.com 5-25-12 2 Danger Warning Caution

More information

Installation & Operation Manual

Installation & Operation Manual tekmarnet 2 House Control 402 Installation & Operation Manual D 402 09/10 HVAC Systems Replaces: 01/10 Introduction The House Control 402 is designed to operate as part of a complete hydronic heating system

More information

Installation & Operation Manual

Installation & Operation Manual tekmarnet 2 House Control 400 Installation & Operation Manual D 400 09/13 HVAC Systems Replaces: 09/10 Introduction The tn2 House Control 400 is designed to operate all of the mechanical equipment in a

More information

7800 SERIES RM7888A Relay Module

7800 SERIES RM7888A Relay Module 7800 SERIES RM7888A Relay Module SPECIFICATION DATA FEATURES APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically

More information

Inventory Management Guide

Inventory Management Guide EASTERN CANADA Inventory Management Guide Honeywell Residential Combustion is the industry leader in combustion controls for applications including warm air furnaces, boilers, commercial water heaters,

More information

Aquatrol. AQ2000 Series. Electronic Controls for Residential Hydronic Heating. Simple. Powerful. Affordable.

Aquatrol. AQ2000 Series. Electronic Controls for Residential Hydronic Heating. Simple. Powerful. Affordable. Aquatrol AQ2000 Series Electronic Controls f Residential Hydronic Heating Simple. Powerful. Affdable. Contract Install Photos Other products out there that I have dealt with are very difficult to set up,

More information

Installation & Operation Manual

Installation & Operation Manual tekmarnet 2 House Control 403 Installation & Operation Manual D 403 07/11 HVAC Systems Replaces: 09/10 Introduction The House Control 403 is designed to operate as part of a complete hydronic heating system

More information

RA889A Switching Relay

RA889A Switching Relay Switching Relay FEATURES PRODUT DATA High load switching capability. Troubleshooting LED. Push-to-test button. Replaceable transformer fuse. Long-life D relay drive control technology. Relay for use with

More information

L4064B2210 Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 11 1/2 in. insertion

L4064B2210 Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 11 1/2 in. insertion HOME ABOUT US PRODUCTS NEWS & EVENTS SUPPORT & RESOURCES CONTACT US HELP VIEW QUOTE Product Search Buildings Homes Applications & Downloads Cross Reference Product Selection Tool Thermostats Whole House

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3200-Plus Temp Limit / LWCO Control with Thermal Targeting for Water Boilers 120 VAC Input / 24 VAC Burner Circuit PATENT. 7,891,572 INSTALLATION INSTRUCTIONS and OPERATING MANUAL Saves Fuel Features

More information

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers T4031A,B,P; T6031A,B Refrigeration Temperature Controllers FEATURES PRODUCT DATA Wide control temperature range is suitable for controlling ducts, tanks, freezers, coolers, display cases. and defrost termination.

More information

Heat Link. Technical Guide

Heat Link. Technical Guide Heat Link Stat Link Technical Guide Third Version, May 2011 1 Table of Contents Thermostatic Zones Defined...................................... 4 StatLink System Components.....................................

More information

Installation & Operation Manual

Installation & Operation Manual tekmarnet 2 House Control 400 Installation & Operation Manual D 400 09/10 HVAC Systems Replaces: 01/10 Introduction The House Control 400 is designed to operate as part of a complete hydronic heating system

More information

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers A Aquatrol Temperature Compensator for s Features PRODUCT DATA Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature. Selectable Warm Weather

More information

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override Date Code - Data rochure oiler Control 265 D 265 10/03 The tekmar oiler Control 265 can control the supply water temperature on up to three modulating boilers based on outdoor temperature or setpoint requirements.

More information

- Data Brochure Boiler Control 274

- Data Brochure Boiler Control 274 - Data Brochure Boiler Control 274 274_D 03/17 The Boiler Control 274 operates up to four on/off boilers to provide outdoor reset operation, domestic hot water and setpoint operation with priority. When

More information

T7079A,B Solid State Remote Temperature Controllers

T7079A,B Solid State Remote Temperature Controllers T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature

More information

7800 SERIES EC7823/RM7823 Relay Module

7800 SERIES EC7823/RM7823 Relay Module 7800 SERIES EC7823/RM7823 Relay Module FEATURES SPECIFICATION DATA APPLICATION The Honeywell EC7823/RM7823 is a microprocessor based Flame Detector Relay that can be fitted with any 7800 SERIES amplifier

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3200-Plus Temp Limit / LWCO Control with Thermal Targeting for Water Boilers 120 VAC Input / 24 VAC Burner Circuit PATENT. 8,931,708; 8,844,834; 7,891,572; others pending INSTALLATION INSTRUCTIONS

More information

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001 SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can

More information

RA889A Switching Relay

RA889A Switching Relay Switching Relay INSTALLATION INSTRUTIONS APPLIATION The Switching Relay provides intermediate switching of line- and low-voltage devices from a line- or low-voltage controller and is typically applied

More information

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001 SLATE Sub-Base Module R8001S9001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

B-40/B-41 Modulating Temperature Controller

B-40/B-41 Modulating Temperature Controller INSTALLATION & OPERATING INSTRUCTIONS B-40/B-41 Modulating Temperature Controller For Raytherm Boilers & Water Heaters H2 514-4001 WH2 2100-4001 Catalog No. 5000.70 Effective: 12-21-11 Replaces: NEW P/N

More information

Outdoor Reset IQ Option Card, p/n

Outdoor Reset IQ Option Card, p/n Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...

More information

Smart ways to save energy IntelliCon INSTALLATION MANUAL

Smart ways to save energy IntelliCon INSTALLATION MANUAL Smart ways to save energy IntelliCon INSTALLATION MANUAL, LLC 516-676-0777 www.llc.com 3/6/2006 Air Conditioning General Instructions: General Wiring Instructions 2-1 2 Stage Air Cooled Air Conditioners

More information

Q7800H Integrated Burner Control Subpanel

Q7800H Integrated Burner Control Subpanel Q7800H Integrated Burner Control Subpanel INSTALLATION INSTRUCTIONS FEATURES Unique subpanel design eliminates extensive wiring in the OEM control panel. One subpanel design covers multiple applications.

More information

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand Date Code - Data Brochure Universal Reset Control 374 D 374 10/03 The tekmar Universal Reset Control 374 is designed to maximize the comfort and effi ciency provided by a hydronic heating system. The control

More information

Project Name: Location: Engineer: Contractor: I. GENERAL

Project Name: Location: Engineer: Contractor: I. GENERAL Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL I. PRODUCT Rep: Date: A. Supply and install modulating and condensing boiler(s) as specified

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3250-Plus Temp Limit / LWCO Control with Thermal Targeting for Water Boilers 120 VAC Operating Voltage PATENT. 8,931,708; 8,844,834; 7,891,572; others pending INSTALLATION INSTRUCTIONS and OPERATING

More information

L7224A,C; L7248A,C,L Oil Electronic Aquastat Controllers

L7224A,C; L7248A,C,L Oil Electronic Aquastat Controllers L74A,C; L748A,C,L Oil Electronic Aquastat Controllers APPLICAION he L74A,C and L748A,C,L Oil Electronic Aquastat Controllers provide electronic temperature sensing in a UL limit-rated control with a single

More information

- Data Brochure D 260. Boiler Control /09

- Data Brochure D 260. Boiler Control /09 - Data Brochure Boiler Control 260 D 260 03/09 The Boiler Control 260 is designed to control a single stage heat source in order to provide outdoor reset or Domestic Hot Water () operation. The control

More information

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL The EM-10 Boiler Temperature Control (BTC) is an efficient boiler operator with a digital LCD display with backlight, a boiler pump

More information

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module 7800 SERIES RM7840E,G,L,M; EC7840L Relay Module SPECIFICATION DATA Valve Proving features including: VPS test time When (Never, Before, After, Split or Both) FEATURES APPLICATION The Honeywell RM7840 is

More information

Temperature & Humidity Controllers

Temperature & Humidity Controllers Electromechanical Temperature Controls T631 Air witch Controller Air witch Controller with heavy-duty corrosion resistant steel case. uitable for lift motor rooms, farm storage areas etc. Line voltage

More information

7800 SERIES RM7888A Relay Module

7800 SERIES RM7888A Relay Module 7800 SERIES RM7888A Relay Module FEATURES SPECIFICATION DATA APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically

More information

Installation & Operation Manual

Installation & Operation Manual tekmarnet 2 House Control 406 Installation & Operation Manual 406_D 11/12 Alternative Energy Replaces: 12/11 Introduction The tn2 House Control 406 is designed to operate the equipment in a 2-pipe, single

More information

T6984 A,D,E Electronic Floating Control Thermostats

T6984 A,D,E Electronic Floating Control Thermostats T6984 A,D,E Electronic Floating Control Thermostats FEATURES PRODUCT DATA PI (proportional and integral) control action provides accurate, stable room temperature control. T6984 models are used with Series

More information

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR 5:1 FIRING RATE MODULATION LESS THAN 20 ppm NOx DIRECT VENT FLEXIBILITY TO 100 FEET 96% AFUE

More information

Outdoor Reset IQ Option Card, p/n

Outdoor Reset IQ Option Card, p/n Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...

More information

T7984 A,B,C Electronic Modulating Control Thermostats

T7984 A,B,C Electronic Modulating Control Thermostats T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in

More information

L8151A Triple Aquastat Relay

L8151A Triple Aquastat Relay L85A riple Aquastat Relay he L85A is a remote bulb controller for use with hydronic heating systems that include domestic hot water service. Provides high limit, low limit, and circulator control for maintaining

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

Sola Hydronic Control. An Eco-Friendly Solution.

Sola Hydronic Control. An Eco-Friendly Solution. Sola Hydronic Control An Eco-Friendly Solution. Honeywell s Sola Boiler Control saves you money and reduces your carbon footprint! Efficient Boiler Control Honeywell s Sola Boiler Control offers energy

More information

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153 INDEX GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 Model(s) Page(s) Flush Mount Fan/Limit/Attic Fan Control... 152 GAS DRYER VALVES 153 Model(s)

More information

ARM SERIES Switching Relays With Priority

ARM SERIES Switching Relays With Priority Models ARM-2P ARM-3P ARM-4P ARM-6P AD-1 AD-4 ARM SERIES Switching Relays With Priority INSTALLATION, OPERATION & MAINTENANCE MANUAL ARM-2P ARM-4P AD-1 ARM-3P ARM-6P AD-4 Information and specifications

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3200-Plus Temp Limit / LWCO Control with Thermal Targeting for Water Boilers 120 VAC Input / 24 VAC Burner Circuit PATENT. 8,931,708; 8,844,834; 7,891,572; others pending INSTALLATION INSTRUCTIONS

More information

Interrupted Ignition Series Oil Primary Control

Interrupted Ignition Series Oil Primary Control Interrupted Ignition Series Oil Primary Control Application Guide & Installation Instruction for ICM1511*, ICM1512*, ICM151*, ICM1514* For more information on our complete range of American-made products

More information

D896 Automatic Vent Damper

D896 Automatic Vent Damper D896 Automatic Vent Damper FEATURES PRODUCT DATA 4-wire plug receptacle. Includes wiring harness on select models to fit plug receptacle onto S86/S8600/S860/S860 /L748/L848 or Penn Baso G60 or G66. For

More information

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA ENGINEERING DATA CONTROLS THERMOSTATS Bulletin No. 210125 November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS L21 SERIES THERMOSTATS HEAT/COOL SYSTEMS Features (All Models): Extra

More information

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES 5 FLOOR-STANDING AND 5 WALL-MOUNT MODELS FROM 50,000 TO 285,000 BTU/HR FIRING RATE MODULATION TO 5:1 LESS THAN 20 ppm NOx

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3150 Combination Low Water Cut-Off & Universal Temperature Limit Control for Oil-Fired Boilers 120 VAC Operating Voltage PATENT S. 7,891,572; 8,931,708 INSTALLATION INSTRUCTIONS and OPERATING MANUAL

More information

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules 7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules SPECIFICATION DATA FEATURES APPLICATION The Honeywell EC7895/RM7895/RM7896 is a microprocessor based integrated burner control for automatically

More information

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface

More information

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL The SF-10 Temperature Control () is an efficient boiler operator with a digital LCD display with backlight, a boiler pump output, and an alarm. The

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Hydronic Mechanical Panels

Hydronic Mechanical Panels Hydronic Assemblies Inc. 56 Horse Hill Rd Concord NH 2015-2016 Hydronic Mechanical Panels Contact 4805 Main St. Waitsfield, Vermont 05673 Phone : 802-583-5500 WWW.Houseneeds.com Hydronic Assemblies Inc.

More information

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform Versa IC Platform VERSA IC Integrated Control Platform Raypak s VERSA IC combines modulating temperature control, safety limits, and ignition programming into one user- friendly Integrated Control Platform.

More information

Inventory Management Guide

Inventory Management Guide MID-ATLANTIC Inventory Management Guide Honeywell Residential Combustion is the industry leader in combustion controls for applications including warm air furnaces, boilers, commercial water heaters, hearth,

More information

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223 Dial the desired duration of the period. Press start button at the time of day you want the UnOcc. period to begin. light turns on. 0 = always = always Pump / Vlv System Pump Zone / Cooling NRTL/C LR 58

More information

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic R Vie Menu % % 1 2 Item F! WWS Vie Menu % % 1 2 Item F! WWS 70 LR 58233 E150539 Universal Reset Control 363 - Data Brochure D 363 12/08 The Universal Reset Control 363 is a microprocessor based control

More information

L7224U Oil Electronic Aquastat Controller

L7224U Oil Electronic Aquastat Controller L74U Oil Electronic Aquastat Controller APPLICATION The EnviraCOM enabled L74U Oil Electronic Aquastat Controller provides electronic temperature sensing in a UL limit-rated controller with a single sensing

More information

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS SC-3 Controller MODULAR BOILER CONTROLLER SERIES INSTALLATION AND OPERATING INSTRUCTIONS SC-3 Applications Space Heat Systems With Outdoor

More information

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

be liable for any other loss or damage, whether direct, indirect, incidental or consequential. Integrated HydroStat 3200-Plus for Slant Fin Boilers Part No. 48-3200-03 and 48-3200-04 120 VAC Input / 24 VAC Burner Circuit PATENT S. 8.391,708; 7,891,572; 8,844,834; Others Pending INSTALLATION INSTRUCTIONS

More information

- Data Brochure Mixing Control 361

- Data Brochure Mixing Control 361 TIME PRGM 1 2 AMPM UN OVR S M T W T F S - Data Brochure Mixing Control 361 D 361 05/00 The Mixing Control 361 is designed to control the supply water temperature to a hydronic system in order to provide

More information

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS SC-9 Controller MODULAR BOILER CONTROLLER SERIES INSTALLATION AND OPERATING INSTRUCTIONS SC-9 Applications Space heat systems with outdoor reset Constant temperature setpoint control Any of these in combination

More information

T6984F,G Electronic Floating Control Thermostats

T6984F,G Electronic Floating Control Thermostats T6984F,G Electronic Floating Control Thermostats FEATURES PRODUCT DATA P+I control action provides accurate, stable room temperature control. Used with ML644 Series 60 Direct Coupled Damper Actuators.

More information

S9360A, S9361A, S9380A, S9381A Integrated Boiler Controllers

S9360A, S9361A, S9380A, S9381A Integrated Boiler Controllers S9360A, S9361A, S9380A, S9381A Integrated Boiler Controllers INSTALLATION INSTRUCTIONS SPECIFICATIONS IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances.

More information

BB3000 Series. Application. Features. Injection Pump Control General Instructions

BB3000 Series. Application. Features. Injection Pump Control General Instructions BB3000 Series Injection Pump Control General Instructions Application The TAC Erie BB3000 Injection Pump Control with outdoor reset provides accurate control of the water temperature in the secondary (radiant)

More information

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: A. Supply and install modulating and condensing boiler(s) as specified herein. Date:

More information

THERMOSTATS THERMOSTATS HEATING AND COOLING

THERMOSTATS THERMOSTATS HEATING AND COOLING THERMOSTATS HEATING AND COOLING LASCO CONTROLS Deluxe Horizontal Thermostats 36-0214 25 Millivolt Heat only 36-0215 1 36-0216 25 24 Volt Heat only 36-0217 1 36-0218 25 24 Volt Heat/Cool 36-0219 1 Note:

More information

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules PRODUCT DATA indicate the presence of flame when used with 7800 SERIES and R7140 Relay Modules.

More information

- Data Brochure Steam Control 279

- Data Brochure Steam Control 279 - Data Brochure Steam Control 279 D 279 12/07 The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The control determines the on time of the

More information

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler D E S I G N E D T O L E A D TWZ/CT/ODV Series Oil-Fired Hot Water Boilers (Less Tankless Heater) Installation Supplement for boilers equipped with honeywell L7248L 2012 Compliant boiler control These instructions

More information

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071 SLATE UV Ampli-Check Flame Amplifier R8001S1071 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform.

More information

7800 SERIES 22-Terminal Universal Subbase

7800 SERIES 22-Terminal Universal Subbase 7800 SERIES 22-Terminal Universal Subbase FEATURES PRODUCT DATA Q7800B003/2003/U Metal Wall-mount subbase Q7800A005/2005/U Plastic Wall-mount subbase Quick-mount wiring subbase for all 7800 SERIES Relay

More information

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031 SLATE Rectification Ampli-Check Flame Amplifier R8001V1031 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single

More information

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module SPECIFICATION DATA EC7890 APPLICATION RM7890 The Honeywell EC7890A,B/RM7890 is a microprocessor based integrated burner control for automatically fired gas,

More information

- Data Brochure Mixing Control 360

- Data Brochure Mixing Control 360 - Data Brochure Mixing Control 360 D 360 03/09 The Mixing Control 360 is designed to control the supply water temperature to a hydronic system in order to provide outdoor reset or setpoint operation. The

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: Date: A. Supply and install modulating and condensing boiler(s)/water heater(s)

More information