Capri B Cast iron combination oil-fired boiler with water tank

Size: px
Start display at page:

Download "Capri B Cast iron combination oil-fired boiler with water tank"

Transcription

1 C Cast iron combination oil-fired boiler with water tank Life-enhancing heat GB

2 Cast iron combination oil-fired boiler with water tank RELIABILITY SAFETY EASY OPERATION EASE OF MAINTENANCE

3 Life-enhancing heat is the new oil-fired, combination, floor-standing, system boiler (central heating + production of domestic hot water and water tank), entirely designed and manufactured by Fondital. The range includes 12 models, with heat outputs from 24 to 43 kw, available with open chamber (BTF) and sealed chamber (BTFD), both can be supplied with double flow connection for systems with low and high temperature zone (versions V: BTFV, BTFDV). The heat exchanger is made of cast iron (EN-GJL-200) with three smoke passes, the design of the combustion chamber allows the flame to fully develop and to spread on an ample surface of exchange, thus absorbing superior quantities of heat while allocating a low thermal load on walls. A high-thickness insulation completely covers the boiler body, avoiding wasteful and detrimental heat dispersions toward the outside. The casing is made of electro-galvanic finished sheet panels, painted with epoxy-polyester powders for the longest lifetime. The domestic hot water supply is obtained by means of a 130-lt., glass enameled water tank, equipped with high efficiency coil exchanger, magnesium anode and insulated with a thick layer of expanded polyurethane. The water tank interior can be inspected. The efficiency rating for all models, according to 92/42/ EC, is two stars. V models only The control panel includes a printed circuit board and master switch with light, operating mode selector, domestic hot water and central heating temperature adjusting selectors, water pressure gauge, led thermometer which acts as diagnostic indicator as well, overheating reset button. The control panel can also host a digital, two channel programmer, managing heating unit, which is supplied as standard with V models, or an electromechanical programmer optionally supplied for all other models. The heating unit can be connected to a thermostat and it can also operate in sliding temperature mode by connecting an external probe, supplied upon request (code: 0SONDAES01). A remote control can be connected to the heating unit (optional equipment), which together with an external probe (code: 0KSONEST00) allows for improved management of the heating unit. In order to manage a multiple zone central heating system, a suitable kit is available as an accessory which is capable of managing three heating zones and, when coupled by an external probe (standard with the kit) allows for sliding temperature operation mode; the probe is to be connected to the printed circuit board of the heating unit. The remote control is also designed for three central heating zone system management. The available combinations of different zone management printed circuit board, remote control and external probe are listed below. MODEL ZONE MANAGEMENT PCB REMOTE CONTROL EXTERNAL PROBE NOTES CAPRI B NO NO 0SONDAES01 To be connected to the heating unit printed circuit board. CAPRI B NO YES 0KSONEST00 To be connected to the remote control CAPRI B YES NO 0SONDAES01 To be connected to the heating unit printed circuit board. CAPRI B YES YES 0SONDAES01 To be connected to the heating unit printed circuit board. CAPRI BV YES* NO 0SONDAES01* To be connected to the heating unit printed circuit board. CAPRI BV YES* YES 0SONDAES01* To be connected to the heating unit printed circuit board. * supplied as standard

4 Cast iron combination oil-fired boiler with water tank DIMENSIONS TFD VERSION M1 D M2 40 R1 R M 144 R C S F Model M R M1 R1 M2 R2 C F S D FLUE GAS DISCHARGE mm COMBUSTION AIR INTAKE mm BTF/BTFV 23 G 1 G 1 G 1 G 1 G 1 G 1 G 3/4 G 3/4 G 1/ BTF/BTFV 33 G 1 G 1 G 1 G 1 G 1 G 1 G 3/4 G 3/4 G 1/ BTF/BTFV 43 G 1 G 1 G 1 G 1 G 1 G 1 G 3/4 G 3/4 G 1/ BTFD/BTFDV 23 G 1 G 1 G 1 G 1 G 1 G 1 G 3/4 G 3/4 G 1/ M CH flow C DHW flow F Domestic cold water inlet R CH return S Re-circulation M1 High temperature CH flow (V version) R1 High temperature CH return (V version) M2 Low temperature CH flow (V version) R2 Low temperature CH return (V version) BTFD/BTDV 31 G 1 G 1 G 1 G 1 G 1 G 1 G 3/4 G 3/4 G 1/ BTFD/BTDV 43 G 1 G 1 G 1 G 1 G 1 G 1 G 3/4 G 3/4 G 1/ ACCESSORIES Item Description Code Remote control 0CREMOTO02 External probe for remote control 0KSONEST00 External probe for use without remote control 0SONDAES01 Electric kit managing 3 central heating zones via remote control. Equipped with external probe. 0CIRCSTA11 Daily timer kit 0KITBEST04 Weekly timer kit 0KITBEST05

5 Life-enhancing heat HYDRAULIC LAYOUTS: B MODEL Domestic cold water PR: CH PUMP PS: DHW PUMP TS: LIMIT THERMOSTAT TA1: ZONE 1 ROOM THERMOSTAT (OPTION) S1: CH PROBE EXTERNAL PROBE WATER TANK WATER TANK PROBE TS S1 PS TS Domestic hot water HEAT EXCHANGER PR TA 1 Or ZONE 1 HIGH TEMPERATURE REMOTE CONTROL BV MODEL Domestic cold water PR: CH PUMP PS: DHW PUMP P1: HIGH TEMPERATURE CH PUMP P2: LOW TEMPERATURE CH PUMP TS: LIMIT THERMOSTAT TSM: LOW TEMPERATURE LIMIT THERMOSTAT VM: MIXING VALVE TA1: ZONE 1 ROOM THERMOSTAT (OPTION) TA2: ZONE 2 ROOM THERMOSTAT (OPTION) TS EXTERNAL PROBE S1 HEAT EXCHANGER PS PR WATER TANK COLLECTOR WATER TANK PROBE P1 M VM P2 TSM Domestic hot water ZONE 1 HIGH TEMPERATURE TA 1 LOW TEMPERATURE CH FLOW PROBE ZONE 2 LOW TEMPERATURE TA 2 Or REMOTE CONTROL

6 Cast iron combination oil-fired boiler with water tank The manufacturer reserves the right to implement modifications without notice. MODEL TECHNICAL DATA BTF / BTFD / BTFV / BTFDV Efficiency rating Heat input Qn kw Heat output Pn kw Efficiency at nominal load % Efficiency at reduced load (30%) % Flue gas heat loss % Casing heat loss % No. of elements of heat exchanger CO 2 value % Flue gas temperature C Bacharach number <1 <1 <1 Flue gas flow rate Kg/h Load loss flue gas side Pa Combustion air flow rate m 3 /kw Water content l CH minimum flow rate l/h Load loss water side ( T=10K) Pa Temperature holding heat loss ( T=50K) % CH water temperature adjustment C Maximum CH working pressure bar CH expansion vessel capacity l DHW expansion vessel capacity l DHW temperature adjustment C Maximum DHW working pressure bar DHW supply ( T=30K) l/10 min Voltage/Frequency V/Hz 230/50 230/50 230/50 Power fuse A Height mm Width mm Depth mm BURNER TECHNICAL DATA MODEL Fuel Oil 1.4 E. Hi=10210 Kcal/kg 20 C Nozzle brand Delavan W, Steinen Q, Danfoss S Nozzle type Usgal/h Nozzle angle 60 W 60 W 60 B Oil pressure pre-adjustment bar Oil consumption Kg/h 2.24 ± 4% 3.06 ± 4% 3.98 ± 4% Pump depression bar > -0.4 > -0.4 > -0.4 Pre-heater W Fuel head pre-adjustment fix fix fix Uff. Pub. Fondital - CTC 03 C Giugno 2006 ( /2006) 9PCGB03C151 FONDITAL S.p.A VESTONE (Brescia) Italy - Via Mocenigo, 123 Tel Fax e mail: info@fondital.it -

Capri R CH only, oil-fired, cast iron boiler

Capri R CH only, oil-fired, cast iron boiler C 153-01 CH only, oil-fired, cast iron boiler Life-enhancing heat GB CH only, oil-fired, cast iron boiler RELIABILITY SAFETY EASY TO OPERATE EASE OF MAINTENANCE Life-enhancing heat CAPRI R range includes

More information

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat C 146-02 made in Italy Elba Dual Cast-iron, floor-standing boiler High quality Italian product Life-enhancing heat GB Cast-iron, floor-standing boiler Elba Dual RELIABILITY SAFETY QUALITY EASY TO OPERATE

More information

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat C 083-03 Bali R Cast-iron boilers with atmospheric gas-fired burner Life-enhancing heat GB Cast-iron boilers with atmospheric gas-fired burner Bali R Easy installation Silent operation Long life Wide range

More information

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat C 223-01 made in Italy Nias Dual Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat GB Wall-hung boilers, forced draught, sealed chamber with

More information

C Tahiti. condensing

C Tahiti. condensing C 227-01 m a d e i n I ta ly Tahiti condensing Condensing, pre-mixed, wall-hung boilers KC 24 KC 28 - KC 32 indoor, instantaneous, combination boilers KR 24 KR 38 - KR 32 indoor, central heating only boilers

More information

Condensing, pre-mixed, wall-hung gas boilers with water tank

Condensing, pre-mixed, wall-hung gas boilers with water tank C 271-01 made in Italy Nias condensing Condensing, pre-mixed, wall-hung gas boilers with water tank Life-enhancing heat GB Condensing, pre-mixed, wall-hung boilers with water tank Nias CONDENSING HIGH

More information

MINORCA KC - KR - KRB 24

MINORCA KC - KR - KRB 24 EN MINORCA KC - KR - KRB 24 MINORCA KC WALL-HUNG CONDENSING COMBI BOILER Available heat outputs: Ultra-compact Electronic flow control for heating water LCD user interface with diagnostics Ideal for low-temperature

More information

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE IST 03 C 202-01 ELBA DUAL INSTALLATION, USE AND MAINTENANCE GB Thank you for choosing our boilers. Please read these installation and maintenance instructions with care. Please note that the boiler must

More information

HORIZONTAL HOT WATER CYLINDER WHPF BO

HORIZONTAL HOT WATER CYLINDER WHPF BO IST 03 C 197-01 HORIZONTAL HOT WATER CYLINDER WHPF BO FOR CONNECTION TO BOILERS MODEL: ELBA, ELBA DUAL, BALI R, MOOREA, MALDIVES R GB S Dear Customer, Thank you for choosing our company and product. Please

More information

FORMENTERA KC - KRB - KR

FORMENTERA KC - KRB - KR EN FORMENTERA KC - KRB - KR 12-24-28-32 FORMENTERA KC WALL-HUNG CONDENSING COMBI BOILERS A A Available heat outputs: Modulation range 1:9 Touch scrn user interface User interface to manage thr different

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

Light oil - kerosene burner

Light oil - kerosene burner Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6

More information

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C ALKON 50 C ALKON 70 C WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) OUTPUT RANGE from 50 to 560 kw (in battery) WORKING TEMPERATURE no limit on

More information

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION FONDERIE SIME S.p.A. of Via Garbo 27 - Legnago (VR) - Italy declares that its diesel-burning boilers are produced in accordance with the requirements of article 3 paragraph 3 of Directive PED 97/23/EEC

More information

ACCUMULATION OF EUROPEAN CLASS

ACCUMULATION OF EUROPEAN CLASS ACCUMULATION OF EUROPEAN CLASS Total comfort MODEL nominal output kw minimum output kw DUA PLUS B TN DUA PLUS B TFS natural draught room sealed forced draught 28 12.4 28 12.4 DUA PLUS B was born from the

More information

ANTEA KC - KR - KRB

ANTEA KC - KR - KRB EN NTE KC - KR - KRB 12-24 - 28 NTE KC WLL-HUN CONDENSIN COMBI BOILER vailable heat outputs: Ultra-compact Electronic flow control for heating water LCD user interface with diagnostics Room temperature

More information

SPECIFICATIONS - NIKE

SPECIFICATIONS - NIKE Wall-mounted instant boilers NIKE Mini kw Special is the ideal Immergas solution for modern building and wherever space is limited and has to be made the most of. Simple to use and easy to install, thanks

More information

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready CITY PLUS Wall-hung condensing boilers 24 HE 30 HE ErP Ready Quality first of all! Quality components Only the best components are used in the Italtherm boilers Noble materials Brass hydraulic groups,

More information

Light oil burners. One stage operation

Light oil burners. One stage operation Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR

More information

Light oil / kerosene burner

Light oil / kerosene burner Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h

More information

Ideasandformsinevolution

Ideasandformsinevolution Ideasandformsinevolution TYPE natural draught room sealed electric diverting valve RTN 24 CTN 24 E RTFS 24 CTFS 24 E DUA PLUS is a natural draught or room sealed forced draught wall hung gas boiler, with

More information

VICTRIX Superior kw Export VICTRIX Superior kw X Export

VICTRIX Superior kw Export VICTRIX Superior kw X Export Wall-hung condensing VICTRIX Superior kw is the instantaneous sealed chamber wallhung boiler with power of 32 kw which, thanks to condensation technology, is characterised for its high efficiency and guarantees

More information

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank 1 FEATURES Wall-mounted with storage tank Compact wall-mounted open chamber boiler with conventional flue and 45 litre stainless steel storage tank and nominal heat output of 23.7 kw (20,382 kcal/h). AVIO

More information

Floor standing boilers. RMG Mk.II RS Mk.II

Floor standing boilers. RMG Mk.II RS Mk.II Floor standing boilers RMG Mk.II RS Mk.II Caldaie a basamento RMG Mk.II - RS Mk.II The perfect solution for modular combinations RMG Mk.II and RS Mk.II gas boilers are cast-iron made and are developed

More information

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS SIMPLY...UNIQUE Pure technology Clean design and practical panel board with wide Power save display The idea of!dea was born from three concepts: Maximum easiness of use Extreme reliability Highest installation

More information

IST 03 C CYLINDER WHPF BM USE AND MAINTENANCE HANDBOOK

IST 03 C CYLINDER WHPF BM USE AND MAINTENANCE HANDBOOK IST 03 C 185-01 CYLINDER WHPF BM USE AND MAINTENANCE HANDBOOK GB ES Dear Customer, Thank you for choosing our company and our hot water cylinder. Please read these instructions carefully. Cylinder correct

More information

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power

More information

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power

More information

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers Wall mounted condensing boilers VICTRIX 50 is the new wall-mounted central heating condensing boiler. It is pre-arranged for single and cascade operation (up to 3 appliances connected), with the advantage

More information

STILE BEAUTY AND TECHNOLOGY

STILE BEAUTY AND TECHNOLOGY STILE BEAUTY AND TECHNOLOGY STILE, in line with your style Designer White Bordeaux Silver Grey MODEL Nominal input kw Nominal output kw Output to the water min. / max. kw HYDRONIC PELLET FIRE SPACE HEATING

More information

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E Instantaneous wall-hung with open chamber boilers Small wall-mounted open chamber, conventional flue instant boiler. General features. is a wall-mounted, open combustion chamber, conventional flue generator

More information

The mechatronics of EVE 05

The mechatronics of EVE 05 SIMPLY PERFORMANT The wide range TYPE natural draught room sealed fan assisted bithermal heat exchanger mono thermal heat exchanger electric diverting valve DHW plates heat exchanger EVE 05 RTN 24 EVE

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C LIBRA DUAL High quality Italian product GB INSTALLATION USE AND MAINTENANCE IST 04 C 220-02 Dear Customer, Thank you for choosing and buying one of our boilers. Please read these instructions carefully

More information

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty. ARREDO E BENESSERE So old fashioned... An intelligent choice When on a cold winters night the warm glowing flames of the KALDUS boiler are there to welcome you back home, you will be pleased that you decided

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

Oil burners Brûleurs fioul Stookoliebranders

Oil burners Brûleurs fioul Stookoliebranders Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement

More information

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II Caldaie a basamento RMG Mk.II and RS Mk.II gas boilers are cast-iron made and are developed and manufactured in order to meet the demands of heating installations of middle and high output, thanks to the

More information

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25) ALKON CARGO ALKON CARGO model Max/min nominal output Heat input condensing Non-condensing η condensation at 30 part load 35 7,4 35,1 6,7 33,5 34,8 106,3 Efficiency class (directive 92/42) ALKON CARGO is

More information

Easyfire Standalone biomass pellet boiler

Easyfire Standalone biomass pellet boiler Easyfire Standalone biomass pellet boiler DESIGN Essential and pleasant AESTETIC, small size If the humanity is in balance with the resources of nature, the respect for the environment will be possible.

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL PRESSURISED STEEL BOILERS AR 30 AR 1000 RADIALAND - BOILER's INSTALLATION MANUAL version 1.0 / 15-02-2008 The company E. is outstanding in the field of central heating

More information

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual. Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual. The package of the 2R GT OF boiler contains instructions for installation, operation and

More information

S SOLAR RANGE

S SOLAR RANGE GB S 002-02 SOLAR RANGE Solar collectors for on-roof installation Solar collectors for in-roof installation Roof mounting systems for on-roof installation Roof mounting systems for in-roof installation

More information

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS R8215828-01EN - Edition 01-01/02/2007 3300187 CLAS 24 NG (EAA1)...... 3300189 CLAS 24 CF NG (EAA1)...... 3300188 CLAS 28 NG (EAA1)...... Reference

More information

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus 24-28 kw Conventional Combi Gas Boiler Lawa / LawaPlus Conventional Combi Gas Boilers Warmhaus wall-hung gas combi boilers Lawa and LawaPlus, with the advantage of its width as 288mm, are easily fit to

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS W W W. A T T A C K. S K MODEL STRUC TURE OF THE AT TACK BOILERS THE NEW LINE OF ATTACK BOILERS FOR WOOD AND PELLETS 3000 000 6000 4 ATTACK FD PELLET yattack

More information

INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS

INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS CGM-04/392 ER-0170/1996 Thank you for choosing a DOMUSA TEKNIK heating boiler. You have chosen a boiler which will provide the ideal level of comfort

More information

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler MAIN INDEX INDEX 1 VICTRIX PRO 35-55 2 ErP SPECIFICATIONS...5 2 VICTRIX PRO 80-100-120 2 ErP SPECIFICATIONS...6 3 VICTRIX PRO 35-55

More information

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80 Installation, use and maintenance instructions Heavy oil burner CODE MODEL TYPE 3434985 PRESS 60 N 616 T80 3434986 PRESS 60 N 616 T80 291 (2) - 01/2009 Thermal power - Output Operation Fuel Electrical

More information

Burner Comparisons. Typical Competitor s Burner

Burner Comparisons. Typical Competitor s Burner Burner Comparisons INOV8 s Typical Competitor s Burner Automatic nozzle cleanout Yes No Available BTUs rated as input 100,000 to 1,000,000 76,500 to 500,000 Burner Motor - hp 1/5 1/7 Combustion safety

More information

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating Mynute Green k Condensing Wall-Hung Boilers Residential Heating Mynute Green k The right choice for any installation requirements The high flexibility of installation makes MYNUTE GREEN K the condensing

More information

CRIMSON & CRIMSON MAX

CRIMSON & CRIMSON MAX High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial

More information

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A smoke pipes VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 OUTPUT RANGE from 115 to 600 kw OPERATION TEMPERATURE no limit on the return temperature SUPPLY Natural Gas or LPG MODELS 150 230 300 348

More information

Flue gas condensation...

Flue gas condensation... Flue gas condensation... The combustion process occurs when the oxygen in the air, supporting the combustion, and the gas are brought to a temperature such to start a reaction. This reaction is of exothermic

More information

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers NEW NEW NEW NEW NEW NEW NEW TRADITIONAL NIKE/EOLO STAR Wall-hung combi boilers ADVANTAGES ADVANCED ELECTRONICS With Immergas boilers it is all extremely easy. The advanced electronics equipping STAR models

More information

CAST IRON ATMOSPHERIC BOILERS

CAST IRON ATMOSPHERIC BOILERS CST IRON TMOSPHERIC OILERS 006 gas-fired, central heating only, electronic ignition High efficiency boilers designed heating large domestic application. Ideal for installation in any boiler room. Cast-iron

More information

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM S Y S T E M S THE SOURCE OF SUPERIOR SYSTEMS The new Sirrus Radiant wall hung boiler from Sirrus Systems offers good looks, comprehensive safety features and

More information

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc Mikrofill Ethos Condensing combination boiler Maintenance Instructions 24cc IMPORTANT Benchmark Installation, Commissioning and Service Record Log Book is enclosed in your customer information pack. This

More information

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h FORCED CIRCULATION Design pressure 11,76 bar Steam production from 45 to 4.000 Kg/h /V Design pressure 11,76 bar Steam production from 45 to 2.000 Kg/h INDUSTRIAL BOILER ITALY S.R.L. Offices and Production

More information

TAHITI CONDENSING KR 55 - KR 85

TAHITI CONDENSING KR 55 - KR 85 IST 03 C 351-01 TAHITI CONDENSING KR 55 - KR 85 GB INSTALLATION USE AND MAINTENANCE Dear Customer, Thank you for choosing and buying one of our boilers. Please read these instructions carefully. They will

More information

International Markets. Product Catalogue. complementary items

International Markets. Product Catalogue. complementary items 01 2017 International Markets Product Catalogue complementary items COMPLEMENTARY SOLAR THERMAL HEAT PUMPS MODULAR CONDENSING WATER HEATERS FLUES AND ACCESSORIES COMPLEMENTARY STANDARD-EFFICIENCY CONDENSING

More information

RK 50. High Efficiency Condensing Wall Hung Boiler Heating Only. Suitable for Cascade Systems SEDBUK BAND A CE 0694 TA01E011.A0405 TA05E011.

RK 50. High Efficiency Condensing Wall Hung Boiler Heating Only. Suitable for Cascade Systems SEDBUK BAND A CE 0694 TA01E011.A0405 TA05E011. High Efficiency Condensing Wall Hung Boiler Heating Only RK 50 Suitable for Cascade Systems SEDBUK BAND A CE 069 CE 069 RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY RADIANT BRUCIATORI S.p.A. Montelabbate

More information

Design Manual. Pre-assembled unit (LINK) Heating and Cooling/Heating modular groups. Platform PRO

Design Manual. Pre-assembled unit (LINK) Heating and Cooling/Heating modular groups. Platform PRO Design Manual Pre-assembled unit (LINK) Heating and Cooling/Heating modular groups Platform PRO Revision: A Code: D-MNL033 This manual has been drawn up and printed by Robur S.p.A.; whole or partial reproduction

More information

INSTALLATION AND OPERATING INSTRUCTIONS KLIMA

INSTALLATION AND OPERATING INSTRUCTIONS KLIMA INSTALLATION AND OPERATING INSTRUCTIONS KLIMA - 1 - CONTENTS 1.- PRESENTATION... 2 2.- LIST OF COMPONENTS... 3 3.- CONTROL ELEMENTS... 4 4.- INSTALLATION INSTRUCTIONS... 5 4.1 LOCATION... 5 4.2 FLUE...

More information

Ciao Green Condensing Wall-Hung Boilers

Ciao Green Condensing Wall-Hung Boilers Ciao Green Condensing Wall-Hung Boilers Residential Heating Ciao Green A cost-consciuos condensing boiler CIAO GREEN is one of the condensing boilers with the best price-quality ratio on the matket. Kitchen

More information

Parts Available from

Parts Available from Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL

More information

8FUEL OIL CONDENSING BOILERS

8FUEL OIL CONDENSING BOILERS EASYLIFE PROJET GTU (FF) / WINGO SF (FF) GTU 0 GTU 0 FF GTU 00/V GTU 00 FF/V POWER RANGES GTU 0....-. kw... p. 9 GTU 00/V....-. kw... p. 9 GTU 00....-. kw... p. 9 GTU 0 FF....-. kw... p. 9 RESIDENTIAL

More information

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER Servicing Instructions Type C Boilers G.C.N: 4-6-0 47-6-08 47-6-09 47-6-3 LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of Parts 3.2

More information

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_ INSTALLATION AND MAINTENANCE MANUAL IST 03 F 017-01 BLITZ FD_ Aluminium electric radiators with heat transfer fluid GB Dear customer, Thank you for choosing our product. Read this manual carefully before

More information

4FLOOR-STANDING GAS CONDENSING BOILERS

4FLOOR-STANDING GAS CONDENSING BOILERS EASYLIFE PROJECT / SOLNEO / ECODENS RESIDENTIAL DTG (E) 130-15/25 Eco. NOx Plus DTG (E) 1300-15/25 Eco. NOx Plus/B150 DTG (E) 1300-15/25 Eco. NOx Plus/H150 DTG 1300-15/25 Eco. NOx Plus/V130 4FLOOR-STANDING

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8215807-03EN - Edition 03-01/03/2008 3300252 EGIS 24 FF NG (IT)...... 3300179 EGIS 24 FF N...... 3300193 EGIS 24 FF NG (EAA1)...... 3300195 EGIS 24 FF

More information

Mynute Green Condensing Wall-Hung Boilers

Mynute Green Condensing Wall-Hung Boilers Mynute Green Condensing Wall-Hung Boilers Residential Heating Mynute Green The right choice for any installation requirements WIDE RANGE Mynute is available in a wide range of models and outputs, to meet

More information

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS ZENA PLUS WALL-HUNG GAS BOILERS MSL FF: from. to 1 kw for heating only MSL FF + BMR 80 and MSL FF + SR 10: from. to 1 kw for heating and DHW produced by an 80-litre calorifier placed beside the boiler,

More information

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL CONTROL PANEL RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL Lecco, 18th January 12 The company Riello SpA Heating Products Direction Via Risorgimento 13 23900 Lecco ITALY hereby declares

More information

TWO STAGE HEAVY OIL BURNERS

TWO STAGE HEAVY OIL BURNERS TWO STAGE HEAVY OIL BURNERS PRESS N SERIES PRESS 30 N 85/171 342 kw PRESS 45 N 114/205 513 kw PRESS 60 N 171/342 684 kw PRESS 100 N 285/490 1140 kw The PRESS N series of burners covers a firing range from

More information

MPO IQ 87% AFUE. Limited Lifetime Warranty! control. Oil-Fired, High Efficiency, 3-Pass Water Boiler. system GREATER ENERGY SAVINGS

MPO IQ 87% AFUE. Limited Lifetime Warranty! control. Oil-Fired, High Efficiency, 3-Pass Water Boiler. system GREATER ENERGY SAVINGS MPO IQ 87% AFUE Oil-Fired, High Efficiency, 3-Pass Water Boiler control system Features Burnham IQ Control System True Plug & Play Controls Utilizing Burnham IQ Option Cards; Outdoor Reset (with Domestic

More information

thea 35 MR/MN Kondens Wall-mounted condensing boiler

thea 35 MR/MN Kondens Wall-mounted condensing boiler A brand by G20 ENGINEERING thea 35 MR/MN Kondens Wall-mounted condensing boiler thea boiler The range of wall boilers Thea models is completed by Thea 35 MR MN Kondens model. It is a perfect, powerful,

More information

OPX INDUSTRIAL RANGE THERMAL OIL

OPX INDUSTRIAL RANGE THERMAL OIL INDUSTRIAL THERMAL OIL OPX Thermal oil heater, three pass horizontal design, complete with single thermal oil pump, regulation, safety accessories and control panel Design pressure 10 bar The OPX thermal

More information

Prextherm Rsw High efficiency steel pressurised boilers

Prextherm Rsw High efficiency steel pressurised boilers Prextherm Rsw High efficiency steel pressurised boilers > PREXTHERM RSW TOP RELIABILITY AND PERFORMANCES Prextherm RSW range consists in pressurised boilers with reversal flame technology. The historical

More information

DOMESTIC HOT WATER Follow operational sequence

DOMESTIC HOT WATER Follow operational sequence DOMESTIC HOT WATER Follow operational sequence Turn Winter/Summer selector to Summer position. The display is switch on. Go to section A Error 110 flashing Error 131 flashing Turn the selector to reset

More information

Heating Equipment. gas boilers RX GB. installation and servicing instructions

Heating Equipment. gas boilers RX GB. installation and servicing instructions Heating Equipment gas boilers RX GB installation and servicing instructions CONTENTS 1 TECHNICAL FEATURES AND DIMENSIONS 1.1 BOILER DESCRIPTION.............................................. page 1 1.2

More information

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT DOC1066 GB STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 747 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com

More information

Wall-hung boilers. Spare parts catalogue. ecotec plus

Wall-hung boilers. Spare parts catalogue. ecotec plus Spare parts catalogue Wall-hung boilers ecotec plus VU 126/6-5 OV (plus 412) VU 156/6-5 OV (plus 415) VU 186/6-5 OV (plus 418) VU 246/6-5 OV (plus 424) 0020223106_01 GB 10/2015 Content General view of

More information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency

More information

ENERGY TOP. Condensing boiler solutions

ENERGY TOP. Condensing boiler solutions ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for

More information

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus. 24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus www.warmhaus.com Condensing-ErP Premix System Boilers 24/31-28/35-33/40 kw Warmhaus wall-hung gas combi boilers

More information

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23 Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,

More information

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production THE SIMPLEST SOLUTION FOR A CONDENSING BOILER DIVACONDENS D PLUS is the generator of condensation

More information

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios. Alpha Regular Boilers CDR Range CDR heating-only boilers are for use on open-vented or using the Alpha sealed system kit sealed systems. When fitted with a storage cylinder, they are capable of supplying

More information

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units PROFESSIONAL 15 claims MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x burners OUTPUT RANGE from 100 to 900 kw and in battery up to 8 units WORKING TEMPERATURE no

More information

A/23 MFFI - A/27 MFFI

A/23 MFFI - A/27 MFFI A/23 MFFI - A/27 MFFI G.C.N. 47-6-0 / 47-6-2 Servicing Instructions Type C Boilers LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of

More information

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION

More information

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw GAS FIRED ATMOSPHERIC ELECTRONIC VERSION 51-102 kw GENERAL DESCRIPTION 900 D a3 1000 762 672 E 222 The PEGASUS F2 range of atmospheric natural gas-fired boilers are constructed of cast iron finned sections

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL CONTROL PANEL RIELLOtech PRIME INSTALLATION, OPERATION AND MAINTENANCE MANUAL CONFORMITY RIELLOtech control panels conform to: Low Voltage Directive 06/95/EC (ex-directive 73/23/EEC) Electromagnetic Compatibility

More information

en Direct oil-fired space heaters HD... Operator's manual

en Direct oil-fired space heaters HD... Operator's manual 0211670en 002 12.2007 Direct oil-fired space heaters HD... Operator's manual Table of contents 1. Foreword 5 2. Safety information 6 2.1 General recommendations... 6 2.2 Safety devices... 7 2.3 Labels...

More information

Forced draught gas burner

Forced draught gas burner Installation, use and maintenance instructions Forced draught gas burner Code Model Type 3751982 GAS 3 519T80 291 (3) - 02/2010 DECLARATION Declaration of conformity in accordance with ISO / IEC 17050-1

More information

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42) ALKON 90 ALKON 90 MODEL max/min condensing nominal heat output conventional max/min heat input efficiency class (Directive 92/42) kw kw kw ALKON 90 24,0 93,6 21,1 87,5 22-90 Moving in the present with

More information

The guarantee on this appliance is valid for 12 months from the first day of installation.

The guarantee on this appliance is valid for 12 months from the first day of installation. Users Manual Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This Users Manual provides detailed instructions and recommendations

More information