Greenleaf 600 Macerator Toilet Waste Pump
|
|
- Francis Ramsey
- 6 years ago
- Views:
Transcription
1 Greenleaf 600 Macerator Toilet Waste Pump Website: Contact: www. greenleaftrade.co.nz
2 Introduction The Greenleaf 600 toilet macerator waste pump is suitable for use in domestic waste / sewerage installations. The unit can be connected to a standard toilet, shower, vanity and sink unit. It is not recommended for use in conjunction with waste disposal units unless a filter system is fitted in the waste line to screen out any solid foreign objects. The unit can be used in hair salons but again filtering is required to remove any hair that might enter the unit. The unit has one 40 mm inlet on the lower left side of the unit and a discharge port on the top right of the unit. There is also provision for an extra 40 mm inlet connection on the top left. There is one 100mm toilet connection on the front of the unit. The waste pump unit has an over ride switch on the top right hand side of the pump along with a sealed carbon vent. Power to the unit is via a power lead, which can be plugged into a standard wall socket. Operating Principal The macerator unit comprises a tank that stores the waste products/wastewater and an electric powered pump, which grinds and pumps the waste product. The unit is automatically controlled and operated via a pressure switch. The operation of the waste pump will be started when activated by the pressure switch due to either flushing of a toilet or water flowing into the storage unit from a shower, vanity or sink. Technical Data Power Supply 230V / 50 Hz Power Consumption 600 watts Water Temp Range Minimum 1*C to max 90*C Normal Operating Temperature Max 50*C Max Input Flow 270 litres/ min Max Lift Height 9 metres Max Horizontal Distance 90metres Waste Water Connection 1 x 85 mm (adapted to 100mm with coupling) Waste Water Connection 1 x 40 mm (plus 1 sealed connection) Waste Discharge Line 1 x 40 mm Discharge Table for Greenleaf 600 Macerator Waste Pump
3 Safety Warning Please read the following safety guidelines and instructions. Non- compliance with the safety rules and regulations can lead to electric shock, fire or serious injury. The unit is to be used only in the manner described in this instruction sheet. This unit is not suitable for use in swimming pools, paddling pools, or any form of standing water. The unit must not be situated where it is exposed to direct water or rain. The operation of this unit in any situation other than for its recommended use is prohibited. Children should be supervised to ensure they do not interfere with this unit. Carry out a visual inspection of the unit prior to use and on a regular basis. Do not use the device if it is damaged or defective. Do not override the unit. Prior to carrying out any maintenance on the unit the power cord must be disconnected from the mains supply. The power requirements for this unit are 230V 50Hz. Never lift or carry the unit by the power cable.
4 Ensure the power plug is connected in an area that is dry and in a flood proof zone. Foreign Objects To ensure continued reliability of the macerator waste pump, only organic toilet sewerage, water and toilet paper should be passed through the system. No other liquids or solids should be allowed to enter the pump. Other items can cause the waste pump to clog and malfunction. In extreme cases this can lead to the pump seizing our burnout of the electric motor. The maximum temperature of the pumped fluid should not exceed +50*c in permanent operation. The pump must not be used for flammable liquids, gas emitting liquids, explosive liquids, fuel, cleaning agents or any other chemical products. Installation The user is responsible for ensuring that the unit is installed in compliance with any regulations that may pertain to the use of this device. The user / installer will ensure that adequate precautions are taken in regard to protecting the area from flooding / overflow by way of an alarm system or standby pump. The user / installer is responsible for any consequential damage that may arise from installation that may cause flooding, water overflow or any other such event that may occur form the operation of this unit. The supplier accepts no responsibility for any damage caused by non- operation of the unit at any time. It is the user / installer s responsibility to ensure that back up devices and alarms are installed to protect their property at all times. Toilet Waste Connection Inlet The unit can be operated with most standard toilets with a horizontal outflow. The mid point of the horizontal outlet of the toilet should be 180 mm from ground level to match the mid point of the pumps toilet inlet connection. On the front of the unit is an 85 mm toilet inlet. A rubber connector adaptor is supplied with the pump to allow connection of a standard 100 mm toilet pan. This rubber adaptor has an offset feature which allows a variation in the toilet height. A clamping ring is also supplied in the kit and should be used when connecting the toilet to the waste pump unit.
5 Top 40mm Discharge Port This port is located on the top right hand side of the unit. A rubber connector is supplied with the unit to connect to the discharge pipe. The unit is supplied with a right angle rubber connector with a built in non- return valve. Lower Left 40mm Waste Inlet Port The unit has one inlet port on the lower left side. The inlet port is approximately 80 mm from ground level (to centre). A rubber connector is supplied with the unit for connecting to this port. The inlet port has a non- return valve fitted inside the tank unit. Top Left Side 40mm Inlet Port (Sealed Spare) There is a sealed spare inlet port on the top left side. To access this port you will need to cut the solid plastic top off (refer diagram).
6 Pressure Switch Override Button The pressure switch override button is located on the right hand side of the waste pump unit when viewing the pump from the front. Depressing this button will override the pressure switch function and cause the motor to run. Care should be exercised when using this feature as it may cause the motor unit to burn out if it is jammed with a foreign object. Dry Running The unit must not be allowed to run dry at any time. The manufacturers warranty is invalid if it is determined that the unit has been run dry. Venting The waste pump unit is fitted with an active carbon filter and requires no external venting. Initial Startup of the Unit Once installation is complete, flush the toilet and check that all seals and connections are watertight. Check both the discharge pipework from the unit and the other sanitary appliances connections. The motor should run for 5 to 10 seconds to clear the waste fluid (depending on the height of the pipe run). If it runs for more than 20 seconds, check that the pipework is clear, and that the discharge hose is not kinked. There should be no dripping of water from the toilet cistern or any other sanitary appliances, as this will cause the unit to activate repeatedly.
7 Discharge Pipework Horizontal pipe runs must have a minimum fall of 1:200 (5mm per metre) to the soil stack, If a vertical lift is required, it must be made before the horizontal run at the start of the pipe run, It is recommended that a drain- off point is installed to allow the discharge pipework to be drained down before any service work Siphoning If the discharge pipework runs to a level considerably lower than the unit, the resultant syphoning effect can suck out the water seal in the unit. Fitting an air admittance valve at the high point of the pipe run will overcome this problem, Sewer Line Connection The discharge pipework should be connected to a soil stack or waste line. Avoid connecting the outlet pipe to any waste pipe where there is a possibility of the waste back feeding into a sink, shower, vanity etc. Maximum Pumping Height or Distance The following should be observed if the unit is to be used at its outer pumping limits. Use smooth bends (OR 2 X 45 degree bends together) and not 90 degree elbows if possible. Any elbow on the discharge pipe of the unit will create friction loss (roughly 50 cm per elbow to be deducted from the vertical pumping spec.) Trouble Shooting Guide Pump Causes Remedy Slow to discharge or Outlet pipe to long Reposition Pipe Will not discharge Or to high Outlet pipe diameter To small Replace Pipe Partial blockage of outlet Actuate the pump with Override switch. If Problem persist, pump Is blocked, clear blockage Emits a humming noise Pump blocked Check pump and But does not discharge the waste Clear blockage Starts running and discharging accidentally Check valve installed Incorrectly Check valve has failed Open Leak in the tank that causes the water to flow into the macerator and sets it running Reinstall correctly Clean / replace check Valve Repair the leak
8 Runs Continually No humming noise Vertical discharge outlet check Valve to high above the pump Check valve defective Pressure switch defective No Electrical supply Pressure switch defective Reposition check valve Replace check valve Check pressure switch Check electrical supply Press the manual override button If the pump runs check The pressure switch. If override button has no effect check the pump Motor This unit is for domestic use only Toilet Inlet Spare Inlet 40mm Inlet 85mm dia Supplied with 100mm Rubber Connector 40mm Outlet
Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual
Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual Website: Contact: www. greenleaftrade.co.nz greenleaftraders@gmail.com Greenleaf 400 Macerator Toilet Waste Pump Introduction The Greenleaf
More informationGreenleaf 100 Toilet Macerator Waste Pump Instruction Manual
Greenleaf 100 Toilet Macerator Waste Pump Instruction Manual Website: Contact: www. greenleaftrade.co.nz Greenleaf 100 Macerator Toilet Pump System Grey Water Capable Introduction The Greenleaf 100 toilet
More informationSanipack is a compact pump/macerator specially designed to take the waste from a wall hung or back to wall WC pan.
1. escription Sanipack is a compact pump/macerator specially designed to take the waste from a wall hung or back to wall WC pan. I The Sanipack will pump away the waste from a WC, washbasin and shower.
More informationPlease also see 10 golden rules for correct Saniflo installation on
1. Description Sanichasse is a WC-suite with a 6 litre flush and built-in pump macerator. Handwash-basin and shower can also be connected. However the inlet is at the back of the machine which may require
More informationWC2 & WC3 Installation & Maintenance Instructions
WC2 & WC3 Installation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information WC3 shown WC2 WC3 IMPORTANT
More informationManual. WilTec 3/1 Macerator Toilet Pump System Article 50741
Manual WilTec 3/1 Macerator Toilet Pump System Article 50741 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further
More informationSUBMERSIBLE WATER PUMPS
OPERATING & MAINTENANCE INSTRUCTIONS SUBMERSIBLE WATER PUMPS Model Nos. HIPPO-3 and 3A 6/97 Thank you for purchasing this CLARKE, HIPPO Submersible Pump. These highly efficient pumps are designed for pumping
More informationCLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:
CLEAN WATER PUMP MODEL No: Hippo4A Part No: 7230535 OPERATION & MAINTENANCE INSTRUCTIONS 0807 INTRODUCTION Thank you for purchasing this CLARKE clean water pump. This highly efficient pump is designed
More information2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP
2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP 8308 PUMP PARTS BREAKDOWN Ref # Part # Manf. # Descrip on 1 NEP2134 AC 81361 PUMP LID 2 NEP2135 AC 81396 PUMP LID
More informationINSTALLATION AND CARE INSTRUCTIONS
INSTALLATION AND CARE INSTRUCTIONS THESE INSTRUCTIONS MUST BE READ BEFORE INSTALLATION IS ATTEMPTED. FAILURE TO DO SO MAY COMPROMISE WARRANTY. FOLLOWING INSTALLATION PLEASE LEAVE ALL PAPERWORK WITH CLIENT
More information8L DEHUMIDIFIER OPERATING INSTRUCTIONS
8L DEHUMIDIFIER OPERATING INSTRUCTIONS Attention: This Dehumidifier is rated to extract 8L per day in an environment of 80% humidity and temperature of 30 C. This is the world-wide standard for rating
More informationINSTALLATION AND CARE INSTRUCTIONS
INSTALLATION AND CARE INSTRUCTIONS THESE INSTRUCTIONS MUST E READ EFORE INSTALLATION IS ATTEMPTED. FAILURE TO DO SO MAY COMPROMISE WARRANTY. FOLLOWING INSTALLATION PLEASE LEAvE ALL PAPERWORK WITH CLIENT
More informationMAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP
MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP 8104 MAXI-PUMP PARTS BREAKDOWN Re f # 1 2 3 4 5 6 7a 7b 8 9 10 11 12 13 14 15 16 2 Part # NEP2134 NEP2135
More informationOperation Manual. Trash Water Pump ARTICLE Image similar
Operation Manual Trash Water Pump ARTICLE 50781 Image similar Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further
More informationSolidFlo G2 Solid Handling Pumps Product Manual
SolidFlo G2 Solid Handling Pumps Product Manual For Models: SolidFlo G2 1250 (Item #130030) SolidFlo G2 2000 (Item #130031) SolidFlo G2 2650 (Item #130032) SolidFlo G2 3600 (Item #130033) Table of Contents:
More informationSH3020 USER INSTRUCTIONS
DEHUMIDIFIER SH3020 USER INSTRUCTIONS GUARANTEE This product is guaranteed for 2 years from the date of original purchase. If any defect arises due to faulty materials or workmanship, the unit will, either
More informationINSTALLATION AND CARE INSTRUCTIONS
INSTALLATION AN CARE INSTRUCTIONS THESE INSTRUCTIONS MUST BE REA BEFORE INSTALLATION IS ATTEMPTE. FAILURE TO O SO MAY COMPROMISE WARRANTY. FOLLOWING INSTALLATION PLEASE LEAVE ALL PAPERWORK WITH CLIENT
More information12L DEHUMIDIFIER OPERATING INSTRUCTIONS
12L DEHUMIDIFIER OPERATING INSTRUCTIONS Attention: This Dehumidifier is rated to extract 12L per day in an environment of 80% humidity and temperature of 30 C. This is the world-wide standard for rating
More informationPORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER Model: PEL00460 1 CONTENTS Page No. Details 2 Important Safety Information 3 Product Overview 3 Positioning & Installation 4 Installation Errors 4 Control Panel 5 Screen IMPORTANT
More informationTIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL
TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR PUMP 88 PUMP PARTS BREAKDOWN REF # Order # Mfr # Description 1 NEP4 AC 348 Lid Knobs NEP AC 380 Strainer Lid 3 NEP6
More informationMacerator Pumps & Lifting Station. Technical presentation Part 1
Macerator Pumps & Lifting Station Technical presentation Part 1 Index Brief history and product background. Product range & characteristics. Benchmarking with SFA range Installation & Servicing History
More informationIssue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation
Issue 4 Oct 2005 Panamatic Top loading Maxi & Optima 3 Installation Please Do handle the unit with care, to avoid scuffs and scratches during installation. Do not over-tighten plumbing or any other mechanical
More informationEVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.
Date: 25 Jan 2005 Doc. 1:114E TECHNICAL DATA 5979301 EVAC 90, SQUATTING To main vacuum line, connection Ø50 Service door 600 Push button Fresh water supply connection 1/2" MPT BSP 700 700 Flushing mechanism
More informationUSING YOUR PRESSURE SEWER SYSTEM
USING YOUR PRESSURE SEWER SYSTEM A homeowner s manual About this manual This manual will assist you with the operation and maintenance of the pressure sewer system installed on your property. We strongly
More informationGeneral Care and Safety Guide
General Care and Safety Guide Thank you for choosing a Goldair Select Dehumidifier. This Goldair Select appliance has been designed and manufactured to high standards of engineering and with proper use
More informationPaper Shredder. Installation & User Instructions Please keep for future reference 913/0153
Paper Shredder Installation & User Instructions Please keep for future reference 913/0153 Important Please read these instructions fully before installing or using These instructions contain important
More informationVADA - Rain2Main Automatic Rainwater Controller
PRODUCT OVERVIEW / APPLICATION The Vada Rain2Main is designed to select between stored rainwater (when available) and mains supply water, and send this water to your toilet cistern, washing machine, garden
More informationOperating Instructions
Operating Instructions 10L Dehumidifier Attention: This Dehumidifier is rated to extract 10L per day in an environment of 80% humidity and temperature of 30 C. This is the world-wide standard for rating
More information20L Electronic Dehumidifier
Operating Instructions 20L Electronic Dehumidifier Attention: This Dehumidifier is rated to extract 20L per day in an environment of 80% humidity and temperature of 30 C. This is the world-wide standard
More informationPUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:
PUDDLE PUMP PUDDLE PUMP MODEL No: PSP125 Part No: 7230692 OPERATION & MAINTENANCE INSTRUCTIONS 1007 SPECIFICATIONS Model number... PSP125 Rated voltage... 230VAC 50Hz Input power... 293 Watts Maximum delivery
More informationOPERATION & MAINTENANCE INSTRUCTIONS
SUBMERSIBLE PUMPS MODEL NO: PSV3A, PSV4A, PSSV2A & PVP11A PART NO: 7236042, 7236044, 7236050 & 7236060 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC07/17 iss 4 INTRODUCTION Thank you for
More informationWALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS
6 th June 2006 Page 1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding
More informationOperating Instructions
Operating Instructions BA-003 Read and understand this manual before use. Keep this manual for future reference. CONFORMS TO UL STD.No.1017 Certified to CSA STD C22.2 No.243-10 For questions or concerns
More information2.9kW Portable Air Conditioner
Operating Instructions 2.9kW Portable Air Conditioner Item: GCPAC210 General Care and Safety Guide Thank you for choosing this Goldair product. This Goldair appliance has been designed and manufactured
More informationDEHUMIDIFIER MODELS: SD-30E / SD-40E / SD-65E INSTRUCTION MANUAL
DEHUMIDIFIER MODELS: SD-30E / SD-40E / SD-65E INSTRUCTION MANUAL Please read these instructions thoroughly and keep it in a safe place for future reference. CONTENTS FUNCTIONS 2 SAFETY NOTES 2 NAME OF
More informationCLEAN WATER SUBMERSIBLE PUMP
WHAT S IN THE BOX CLEAN WATER SUBMERSIBLE PUMP 550W INSTRUCTION MANUAL SPECIFICATIONS Motor: 550W Max. Flow Rate: 15,500l/h Max. Head: 8.5m Max. Immersion: 7m Min. Suction Depth: 50mm (automatic) 5mm (manual)
More informationPear Kitchen Sink Tap
Pear Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading
More informationElectric Pressure Washer
Electric Pressure Washer S1900 039-8575-4 OWNER S MANUAL If you have any questions or comments, visit our website at www.simoniz.ca or call our toll free hotline 1-866-4SIMONIZ (1-866-474-6664) PLEASE
More informationHEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER
HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER USER MANUAL 01mf_Manuel_EdenPure_ChaufHEA-900_12025.indd 1 ALL SEASON INFRARED HEATER 01mf_Manuel_EdenPure_ChaufHEA-900_12025.indd 2 INSTRUCTION
More information2.9kW Portable Air Conditioner
Operating Instructions 2.9kW Portable Air Conditioner Item: GCPAC290 General Care and Safety Guide Thank you for choosing this Goldair product. This Goldair appliance has been designed and manufactured
More informationGRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions
GRUNDFOS INSTRUCTIONS Sololift2 C-3 Installation and operating instructions English (US) English (US) Installation and operating instructions Original installation and operating instructions. CONTENTS
More informationA few simple steps to ensure perfect water, every time.
A few simple steps to ensure perfect water, every time. Use and Care Guide MODELS: A8CTBOTTLELESSWHT A8CTBOTTLELESSBLK Registration Please visit the website below to register your new water cooler within
More informationManual and Thermostatic Power Shower Units
520M/520TS Manual and Thermostatic Power Shower Units Installation instructions & User guide IMPORTANT: This booklet should be given to the customer after installation and demonstration. WARNING: Under
More informationA4 Laminator. Installation & User Instructions Please keep for future reference 908/6197
A4 Laminator Installation & User Instructions Please keep for future reference 908/6197 Important Please read these instructions fully before installing or using These instructions contain important information
More informationModel Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION
PumpAgents.com - Click here for Pricing/Ordering Model 37045-Series QUIET - FLUSH ELECTRIC TOILET FEATURES Very quiet flush cycle - like a household toilet Single button flush actuator - with dual function
More informationA few simple steps to ensure perfect water, every time.
A few simple steps to ensure perfect water, every time. Use and Care Guide MODELS: A7BOTTLELESS A7BOTTLELESSBLK Registration Please visit the website below to register your new water cooler within the
More informationINSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems
INSTALLATION MANUAL GUTHD2 Universal Two Way Digital Thermostatic Valve for Shower Systems IMPORTANT: To ensure this product is installed properly, you must read and follow these guidelines. The owner/
More informationFAULT FINDING. Water Gas Cassette Toilet FAULT FINDING
Water... 208 Gas... 210 Cassette Toilet... 211 207 WATER FAULTS Water Fault Cause Remedy Water not flowing from any tap when operated but pump runs Pump does not run Water flows from cold tap but not from
More informationUser Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333
User Guide Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE 100 #728492 1056 #728320 FOR PUMP MODELS 185 264 396 633 #728300 #728305 #728310 #728315 1267 #728325 1584 #728330 2245 #728333 Fixed Flow Pumps
More informationZip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water
Installation and Operating Instructions Zip Hydroboil Filtered instant boiling water 01552 Zip Hydroboil 1.5 Litre White 01551 Zip Hydroboil 1.5 Litre Stainless Steel 03552 Zip Hydroboil 3 Litre White
More informationOWNERS INSTRUCTION MANUAL
Congratulations on your purchase of a Kent Portable Electric Appliance. Please read the following instructions carefully before use and retain for future reference. BEFORE FIRST USE Read and follow all
More informationElectric Pressure Washer
Electric Pressure Washer S1700 039-8574-6 Owner s Manual If you have any questions or comments, visit our website at www.simoniz.ca or call our toll free hotline 1-866-4SIMONIZ (1-866-474-6664). PLEASE
More informationDove Eco thermostatic bar mixer shower
Dove Eco thermostatic bar mixer shower Eco Statement This product has been fitted with a flow regulator to deliver a maximum flow rate of 6 litres per minute. Installation and operating instructions Installers
More informationDIRTY WATER SUBMERSIBLE PUMP
WHAT S IN THE BOX DIRTY WATER SUBMERSIBLE PUMP 780W INSTRUCTION MANUAL SPECIFICATIONS Motor: 780W Max. Flow Rate: 15,700l/h Max. Head 8m Max. Immersion: 7m Min. Suction Depth 50mm Max Particle Size: Ø35mm
More informationHOT WASHER MODEL NO: KING150
WARNING: Do not use the hot washer without reading this manual HOT WASHER MODEL NO: KING150 PART NO: 7320175 OPERATION & MAINTENANCE INSTRUCTIONS LS1215 INTRODUCTION Thank you for purchasing this CLARKE
More informationHOT TANK INSTALLATION AND OPERATING INSTRUCTIONS. Model #: 5000
HOT TANK INSTALLATION AND OPERATING INSTRUCTIONS Model #: 5000 INSTALLATION GUIDE BEFORE YOU BEGIN YOUR INSTALLATION: 1 2 3 4 Turn off water supply. Observe all local plumbing codes. Inspect waste and
More informationPORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER Model: PEL00461 1 CONTENTS Page No. Details 3 Important Safety Information 4 Introduction 4 Positioning 4 Installation 5 Control Panel 6 Remote Control 6 Operation Modes 7 Water
More informationOperation Manual. Pond Pump Series HJ and CQP
Operation Manual Pond Pump Series HJ and CQP Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments,
More informationInstruction Manual for Electric Marine Toilets LT-0E and LT-1E
Instruction Manual for Electric Marine Toilets LT-0E and LT-1E www.nuovarade.com Nuova Rade Electric toilets LT-0E and LT-1E,can be supplied as either 12V or 24V and have been designed to make your life
More informationModel: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE
Ambassador 20 Automatic Carpet Scrubber Model: C8420-115 C8420-240 OPERATION SERVICE PARTS CARE This manual is furnished with each new Minuteman Ambassador 20. This provides the necessary operating and
More informationDIRTY WATER SUBMERSIBLE PUMP KIT
WHAT S IN THE BOX DIRTY WATER SUBMERSIBLE PUMP KIT 1000W INSTRUCTION MANUAL SPECIFICATIONS Motor: 1000W Max. Flow Rate: 18,000l/h Max. Head 9m Max. Immersion: 7m Min. Suction Depth 50mm Max Particle Size:
More informationCPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:
CPE RANGE PUMPS CPE RANGE PUMPS MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos: 7120305 7120310 7120315 7120320 7120325 7120330 OPERATION & MAINTENANCE INSTRUCTIONS GC0514 Contents Specifications...
More informationAPW-VAP-150P High Pressure Cleaner Operator Manual
APW-VAP-150P High Pressure Cleaner Operator Manual BEFORE OPERATING THIS APPLIANCE PLEASE READ THESE INSTRUCTIONS CAREFULLY Item Description OVERVIEW 1. High pressure washer 2. On/off switch 3. Water outlet
More informationPANTHER. Condensate removal pump Installation and operating guide
PANTHER Condensate removal pump Installation and operating guide The PANTHER is a self-contained condensate removal system for use directly inside trunking and highwall-mount air conditioners.the small
More informationSG-DEH-PEX Vertical Dehumidifier Pump Operating Instructions
Model Number: HCB-PEX SG-DEH-PEX Vertical Dehumidifier Pump Operating Instructions The actual pump design may differ from the image on manual. V140627 Operating Instructions Please read and save these
More informationDISPOSER CONTROL CENTER
DISPOSER CONTROL CENTER Installation Manual Model MS The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. The Warning signal alerts
More informationLaing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual
Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual
More information80cm Tower Fan With Remote Control
Operating Instructions 80cm Tower Fan With Remote Control Item: GCTF300 General Care and Safety Guide Thank you for choosing this Goldair Venti product. This Goldair Venti appliance has been designed and
More informationMinimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification
Product Specification ~ Minimum Working Pressure 0.5 bar ~ Maximum Working Pressure 4.0 bar ~ Cold Water Supply Temp 4-20 c ~ Hot Water Supply Temp 55-85 c ~ Fixing Centres 150mm +/- 20mm ~ Outlet size
More informationInstallation Instructions. For the 18 Built-In Dishwasher and Front Color Panels
Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,
More informationBOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration
in tap Boiling water to in tap sink Drain Valve (as high as possible) REDITAP CONNECTION SUMMARY Amp mains supply cold mains water into in tap optional filter cold water in hot water BOILING UNIT Installation
More informationDISPOSER CONTROL CENTER
DISPOSER CONTROL CENTER Installation Manual Model CC-202D The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. The Warning signal
More informationDISPOSER CONTROL CENTER
DISPOSER CONTROL CENTER Installation Manual Model CC-202D WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a hazardous situation
More informationhp Dust Collector With Vacuum Attachment
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationGlass Chimney Hood. Installation & User Instructions Please keep for future reference
Glass Chimney Hood Installation & User Instructions Please keep for future reference 4897549 4897556 Important Please read these instructions fully before installing or using These instructions contain
More informationSUBMERSIBLE WATER PUMP
WHAT S IN THE BOX SUBMERSIBLE WATER PUMP 350W INSTRUCTION MANUAL SPECIFICATIONS Motor: 350W Max. Flow Rate: 7,000l/h Max. Head 5m Max. Immersion: 5m Min. Suction Depth 50mm Max Particle Size: Ø30mm Water
More informatione Bath Fan with Light User s Guide
e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING
More informationIMPORTANT SAFETY INSTRUCTIONS TABLE OF CONTENTS SAVE THESE INSTRUCTIONS!
TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS Table of Contents Page 2 Important Safety Instructions Page 3 General Safety Instructions Page 4 List of Main Parts, Technical Specifications Page 6 Contents
More informationDIRTY WATER SUBMERSIBLE PUMP
WHAT S IN THE BOX DIRTY WATER SUBMERSIBLE PUMP 750W INSTRUCTION MANUAL SPECIFICATIONS Motor: 750W Max. Flow Rate: 15,000l/h Max. Head 8m Max. Immersion: 8m Min. Suction Depth 50mm Max Particle Size: Ø35mm
More informationTarget Monobloc Kitchen Mixer Chrome
Target Monobloc Kitchen Mixer Chrome Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan,
More informationbreeze easytm model # F100-1W
DewStop breeze easytm model # F100-1W Installation Guide Read and Save These Instructions LISTED Questions, Problems, Missing Parts? Please Call 1-360-876-2974 or E-Mail info@dewstop.com please retain
More informationPortable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology
Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology OWNER'S MANUAL Model # KY-34 3046364 Please read owner s manual carefully before operating unit. TABLE OF CONTENTS INTRODUCTION...3
More informationCRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE
No. 9195 CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2007. All rights reserved. No part of this publication may be reproduced by any means without
More informationINSTALLATION GUIDE NZ AU C
DISHWASHER DW60 models INSTALLATION GUIDE NZ AU 591217C 12.17 1 SAFETY AND WARNINGS! WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker.
More information2200W RADIANT HEATER GVARH350. Instruction Manual
2200W RADIANT HEATER GVARH350 Instruction Manual Contents Guide to the Appliance 2 Caring for the Environment 3 Safety Information and Warnings 4 Operation Instructions 5 Care and Maintenance 6 Technical
More informationOltis thermostatic bar mixer
Oltis thermostatic bar mixer Installation and operating instructions Installers please note these instructions are to be left with the user 2180564E February 2009 CONTENTS Page Introduction... 1 Safety
More informationNON-SUBMERSIBLE WATER PUMP
NON-SUBMERSIBLE WATER PUMP MODEL NO: CEB103 PART NO: 7230327 OPERATION & MAINTENANCE INSTRUCTIONS LS0114 INTRODUCTION Thank you for purchasing this CLARKE Water Pump, which is a general purpose pump, suitable
More informationThe Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION
The Marine Throne "all the comforts of home" Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET FEATURES Very quiet flush cycle - like a household toilet Single button flush actuator - with dual
More information1500W CERAMIC HEATER. Instruction Manual
1500W CERAMIC HEATER GVACH110 Instruction Manual Contents Guide to the Appliance 2 Caring for the Environment 3 Safety Information and Warnings 4 Operation Instructions 5 Care and Maintenance 6 Technical
More informationThe Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.
The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. The Warning signal alerts you to potential hazards or unsafe practices which,
More informationBeeline Monobloc Kitchen Mixer Tap
Beeline Monobloc Kitchen Mixer Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the
More informationManual / Handbuch Spare parts list / Ersatzteilliste
Manual / Handbuch Spare parts list / Ersatzteilliste Equipment Imp.-Exp. GmbH Zitterpappelweg 9 D - 22391 Hamburg Tel.: + 49 40 60009468-0 Fax: + 49 40 536 75 01 E - M a i l : i n f o @ w e s c o - n a
More informationWARRANTY TABLE OF CONTENTS TECHNICAL SPECIFICATIONS. Product Warranty Always keep your receipt as proof of purchase. Technical specifications...
4 TABLE OF CONTENTS Technical specifications... 1 Warranty... 2 Important precautions Read first!... 3 Safety features and electrical power information... 5 Parts and diagram list... 6 Assembly and operation
More informationOUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS
OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS IMPORTANT! Read all of these instructions before installing the dishwasher. AUTOMATIC HIGH LOOP The drain hose is fastened to the back of the machine at the
More informationMULTI Hand Vacuum USER GUIDE 1985 SERIES
MULTI Hand Vacuum USER GUIDE 1985 SERIES IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS BEFORE USE. RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. Do not use in rain or leave outdoors while
More informationT550i power shower pump Installation and operating instructions
power shower pump Installation and operating instructions Installers please note these instructions are to be left with the user 2180149H March 2008 CONTENTS Page Plumbing and electrical notes...1 Introduction...2
More informationPANEL HEATER OPERATING INSTRUCTIONS. For Models: CELEPANEL, CELEPANELT
PANEL HEATER OPERATING INSTRUCTIONS For Models: CELEPANEL, CELEPANELT WARNINGS AND SAFEGUARDS 1. Use only the voltage specified on the rating label of the appliance. 2. Keep all objects at least 1 metre
More informationAdjustable Electric Heater
Adjustable Electric Heater User instructions - please keep for future reference GS11 V1.0 Technical information Power Supply: 220-240V ~ 50Hz Wattage: 900W/1200W/20W Element Type: Halogen Life of Lamp:
More informationInstructions for installation and use English. More documents on: H B /09
TM Instructions for installation and use English EN More documents on: www.zodiac-poolcare.com H0538700.B - 2015/09 Read this manual carefully before installing, maintaining or repairing this appliance!
More informationPRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:
WARNING Read the instructions before using the machine PRESSURE WASHER MODEL NO: JETSTAR 1750 PART NO: 7333230 OPERATION & MAINTENANCE INSTRUCTIONS LS0711 INTRODUCTION Thank you for purchasing this CLARKE